GXL-8FU
Inductive Proximity Sensor, GXL Series, Front Sensing, 2.5 mm, SPST-NO, 12 Vdc to 24 Vdc, Pre-Wired
- Manufacturer: PANASONIC
- Product type: Inductive Proximity Sensors
- Sensing Range Max:2.5mm; Thread Size - Metric:-; Sensor Output:Digital; Supply Voltage DC Min:12V; Supply Voltage DC Max:24V; Product Range:GXL Series; SVHC:No SVHC (07-Jul-2017)
- SVHC: To Be Advised
- Product Range: GXL Series
- Sensing Range Max: 2.5mm
- Sensor Output Type: Digital
- Supply Voltage DC Max: 24V
- Supply Voltage DC Min: 12V
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 38.99 € |
| Current stock | 10+ |
| Lead time | 30 days |
DC 2-wire type Micro-size Inductive Proximity Sensor Amplifier Built-in **GXL SERIES** 823 **■** General terms and conditions ............. F-7 **■** Sensor selection guide ................. P.803~ FIBER Related Information ~~ee~~ SENSORS |[ee] **■** Glossary of terms........................ P.1482~ **■** General precautions ................... P.1485~ LASER SENSORS PHOTOELECTRIC SENSORS Conforming to MICRO EMC Directive PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE Ma PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING Cy SYSTEMS ~~—~~ MEASUREMENT ~~a~~ yer SENSORS ~~[Eo~~ **panasonic.net/id/pidsx/global** 2-wire type Oil resistant Flexible cable Different freq. in available type available type available STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC **High performance in micro-size design** HUMAN MACHINE INTERFACES **BASIC PERFORMANCE** ~~aan rrr~~ ENERGY CONSUMPTION VISUALIZATION COMPONENTS **Versatile mounting Reduced wiring operation** FA COMPONENTS Since the sensor is fingertip size, it can be mounted in The wiring cost of the DC 2-wire type is 2/3 that of a a tight space. conventional model. MACHINE VISION SYSTEMS Besides, the possibility of miswiring is reduced. UV CURING **Particularly convenient when many sensors are used.** SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL** **GL GX-M GX-U/GX-FU/ GX-N GX** Wiring of the 3-wire type is Wiring of the 2-wire type is cumbersome. simple and neat. ## ee, **ENVIRONMENTAL RESISTANCE** ~~Ee~~ **Others Flexible cable type Cost performance** The bending durability of its cable is ten times that of the conventional model. The sensor can be mounted on a moving table or a robot arm. Achieve high performance at an affordable price. DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 824 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX** ## **APPLICATIONS** **==> picture [503 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> Detecting wafer frame Detecting aluminum pallet Code reading<br>Wafer<br>Wafer frame<br>**----- End of picture text -----**<br> ## **ORDER GUIDE** ## **GXL-8 type** **==> picture [504 x 390] intentionally omitted <==** **----- Start of picture text -----**<br> Type Appearance (mm in) Sensing range Model No. Output Output operation<br>(Note 1) (Note 2)<br>GXL-8FU<br>Normally open<br>7.40.291 Maximum GXL-8FUI<br>operation<br>8 200.787 distance GXL-8FUB<br>0.315 Normally closed<br>2.5 mm 0.098 in GXL-8FUIB<br>Non-contact DC 2- wire type<br>(0 to 1.8 mm) (0 to 0.071 in) GXL-8HU<br>Normally open<br>8 GXL-8HUI<br>0.315 Stable sensing range<br>23 GXL-8HUB<br>0.3158 0.906 Normally closed<br>GXL-8HUIB<br>Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.<br>The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient<br>temperature drift and/or supply voltage fluctuation.<br>2) “ I ” in the model No. indicates a different frequency type.<br>GXL-15 (Standard) type<br>Type Appearance (mm in) Sensing range Model No. Output Output operation<br>(Note 1) (Note 2)<br>GXL-15FU<br>Normally open<br>8 Maximum GXL-15FUI<br>0.315 operation<br>32 distance GXL-15FUB<br>0.59115 1.260 5 mm 0.197 in GXL-15FUIB Normally closed<br>Non-contact DC 2- wire type<br>(0 to 4 mm) (0 to 0.157 in) GXL-15HU<br>Normally open<br>0.59115 GXL-15HUI<br>Stable sensing range<br>0.59115 301.181 GXL-15HUB Normally closed<br>GXL-15HUIB<br>Front sensing<br>DC 2-wire<br>Top sensing<br>Front sensing<br>DC 2-wire<br>Top sensing<br>**----- End of picture text -----**<br> Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. - 2) “ **I** ” in the model No. indicates a different frequency type. DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 825 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL** **GX-M GX-U/GX-FU/ GX-N GX** ## **ORDER GUIDE** ## **GXL-15 (Long sensing range) type ··· For mounting on non-magnetic material (Note 3)** **==> picture [503 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> Type Appearance (mm in) Sensing range Model No. Output Output operation<br>(Note 1) (Note 2)<br>GXL-15FLU<br>Normally open<br>8 Maximum GXL-15FLUI<br>0.315 operation<br>32 distance GXL-15FLUB<br>0.59115 1.260 8 mm 0.315 in GXL-15FLUIB Normally closed<br>Non-contact DC 2- wire type<br>(0 to 6.4 mm) (0 to 0.252 in) GXL-15HLU<br>15 Normally open<br>0.591 GXL-15HLUI<br>Stable sensing range<br>15 301.181 GXL-15HLUB<br>0.591 Normally closed<br>GXL-15HLUIB<br>Front sensing<br>DC 2-wire<br>Top sensing<br>**----- End of picture text -----**<br> Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. - 2) “ **I** ” in the model No. indicates a different frequency type. - 3) To mount the long sensing range **GXL-15** type on a magnetic body, such as iron, the enclosed aluminum sheet, or any other aluminum sheet having a minimum size of 30 × 39.5 × t 0.3 mm 1.181 × 1.555 × t 0.012 in Aluminum sheet - ( **GXL-15HLU** type: 30 × 30 × t 0.3 mm 1.181 × 1.181 × t 0.012 in), should be inserted between the sensor and the magnetic body. However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator. ## **Flexible cable type and 5 m 16.404 ft cable length type** Flexible cable type and 5 m 16.404 ft cable length type (standard: 1 m 3.281 ft) are also available. ## **• Table of Model Nos.** **==> picture [503 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> Flexible cable of<br>Type Standard Flexible cable type 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type<br>GXL-8FU GXL-8FU-R GXL-8FU-C5 GXL-8FU-R-C5<br>GXL-8FUI GXL-8FUI-R GXL-8FUI-C5 GXL-8FUI-R-C5<br>GXL-8FUB GXL-8FUB-R GXL-8FUB-C5 GXL-8FUB-R-C5<br>GXL-8FUIB GXL-8FUIB-R GXL-8FUIB-C5 GXL-8FUIB-R-C5<br>GXL-8HU GXL-8HU-R GXL-8HU-C5 GXL-8HU-R-C5<br>GXL-8HUI GXL-8HUI-R GXL-8HUI-C5 GXL-8HUI-R-C5<br>GXL-8HUB GXL-8HUB-R GXL-8HUB-C5 GXL-8HUB-R-C5<br>GXL-8HUIB GXL-8HUIB-R GXL-8HUIB-C5 GXL-8HUIB-R-C5<br>GXL-15FU GXL-15FU-R GXL-15FU-C5 GXL-15FU-R-C5<br>GXL-15FUI GXL-15FUI-R GXL-15FUI-C5 GXL-15FUI-R-C5<br>GXL-15FUB GXL-15FUB-R GXL-15FUB-C5 GXL-15FUB-R-C5<br>GXL-15FUIB GXL-15FUIB-R GXL-15FUIB-C5 GXL-15FUIB-R-C5<br>GXL-15HU GXL-15HU-R GXL-15HU-C5 GXL-15HU-R-C5<br>GXL-15HUI GXL-15HUI-R GXL-15HUI-C5 GXL-15HUI-R-C5<br>GXL-15HUB GXL-15HUB-R GXL-15HUB-C5 GXL-15HUB-R-C5<br>GXL-15HUIB GXL-15HUIB-R GXL-15HUIB-C5 GXL-15HUIB-R-C5<br>GXL-15FLU GXL-15FLU-R GXL-15FLU-C5 GXL-15FLU-R-C5<br>GXL-15FLUI GXL-15FLUI-R GXL-15FLUI-C5 GXL-15FLUI-R-C5<br>GXL-15FLUB GXL-15FLUB-R GXL-15FLUB-C5 GXL-15FLUB-R-C5<br>GXL-15FLUIB GXL-15FLUIB-R GXL-15FLUIB-C5 GXL-15FLUIB-R-C5<br>GXL-15HLU GXL-15HLU-R GXL-15HLU-C5 GXL-15HLU-R-C5<br>GXL-15HLUI GXL-15HLUI-R GXL-15HLUI-C5 GXL-15HLUI-R-C5<br>GXL-15HLUB GXL-15HLUB-R GXL-15HLUB-C5 GXL-15HLUB-R-C5<br>GXL-15HLUIB GXL-15HLUIB-R GXL-15HLUIB-C5 GXL-15HLUIB-R-C5<br>Front sensing<br>Top sensing<br>Front sensing<br>DC 2-wire<br>Top sensing<br>Front sensing<br>Top sensing<br>**----- End of picture text -----**<br> DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 826 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX** ## **ORDER GUIDE** ## **Accessories** - **MS-GXL8-4** (Sensor mounting bracket for **GXL-8FU** , **GXL-8HU** type) - **MS-A15F** (Aluminum sheet for **GXL-15FLU** type) **• MS-A15H** (Aluminum sheet for **GXL-15HLU** type) **==> picture [143 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> • MS-GXL8-4 • MS-A15F<br>• MS-A15H<br>**----- End of picture text -----**<br> **==> picture [44 x 106] intentionally omitted <==** **==> picture [63 x 60] intentionally omitted <==** 1 pc. each of M3 (length: 12 mm 0.472 in) truss head screw, nut, spring washer and plain washer is attached. ## **OPTIONS** **==> picture [331 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Model No. Description<br>Sensor mounting MS-GXL15 Mounting bracket for GXL-15 type<br>bracket<br>MS-GXL15-2 Mounting bracket for GXL-15F type<br>**----- End of picture text -----**<br> ## **Sensor mounting bracket** **==> picture [148 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> • MS-GXL15 • MS-GXL15-2<br>MS-GXL15<br>Screws are not supplied. Screws are not supplied.<br>**----- End of picture text -----**<br> DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 827 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL** **GX-M GX-U/GX-FU/ GX-N GX** ## **SPECIFICATIONS** ## **DC 2-wire type** **==> picture [503 x 548] intentionally omitted <==** **----- Start of picture text -----**<br> GXL-15 type<br>Type GXL-8 type Long sensing range<br>Standard<br>(For mounting on non-magnetic body) (Note 2)<br>Standard Front sensing Top sensing Front sensing Top sensing Front sensing Top sensing<br>Item Model No. GXL-8FU GXL-8HU GXL-15FU GXL-15HU GXL-15FLU GXL-15HLU<br>Max. operation distance (Note 3) 2.5 mm 0.098 in ±20 % 5 mm 0.197 in ±10 % 8 mm 0.315 in ±10 %<br>Stable sensing range (Note 3) 0 to 1.8 mm 0 to 0.071 in 0 to 4 mm 0 to 0.157 in 0 to 6.4 mm 0 to 0.252 in<br>Iron sheet 15 × 15 × t 1 mm Iron sheet 20 × 20 × t 1 mm Iron sheet 30 × 30 × t 1 mm<br>Standard sensing object 0.591 × 0.591 × t 0.039 in 0.787 × 0.787 × t 0.039 in 1.181 × 1.181 × t 0.039 in<br>Hysteresis 20 % or less of operation distance (with standard sensing object)<br>Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less<br>Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less<br>Current consumption (Note 4) 0.8 mA or less<br>Non-contact DC 2-wire type Non-contact DC 2-wire type<br>Output • Load current: 3 to 70 mA (Note 5) • Load current: 3 to 100 mA (Note 5)<br>• Residual voltage: 3 V or less (Note 6) • Residual voltage: 3 V or less (Note 6)<br>Utilization category DC-12 or DC-13<br>Short-circuit protection Incorporated<br>Max. response frequency 1 kHz<br>Operation indicator Normally closed type: Red LED (lights up when the output is ON)<br>2-color indicator Normally open type: Lights up in green under stable sensing condition<br>Lights up in red under unstable sensing condition<br>Pollution degree 3 (Industrial environment)<br>Protection IP67 (IEC), IP67G (Note 7)<br>Ambient temperature –25 to +70 °C –13 to +158 °F, Storage: –30 to +80 °C –22 to +176 °F<br>Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH<br>EMC EN 60947-5-2<br>Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure<br>Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure<br>Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each<br>Shock resistance 1,000 m/s [2] acceleration (100 G approx.) in X, Y and Z directions for three times each<br>Sensing Temperature characteristics Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within [+15] –10 [% of sensing range at +20 °C ][+68 °F]<br>range<br>variation Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage<br>Enclosure: PET Enclosure: PBT Enclosure: PET<br>Material Enclosure: PBT, Indicator part: Polyalylate Indicator part: Indicator part: Indicator part:<br>Polyalylate Polyalylate Polyalylate<br>0.15 mm [2] 2-core oil, heat and cold<br>Cable (Note 8) resistant cable, 1 m 3.281 ft long 0.2 mm [2] 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long<br>Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm [2] , or more, cable.<br>Weight Net weight: 12 g approx. Net weight: 20 g approx.<br>Accessories MS-GXL8-4 – MS-A15F MS-A15H<br>(Sensor mounting bracket): 1 set (Aluminum sheet): 1 pc. (Aluminum sheet): 1 pc.<br>Environmental resistance<br>**----- End of picture text -----**<br> Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. - 2) To mount the long sensing range type on a magnetic body, such as iron, the enclosed aluminum sheet, or any other aluminum sheet having a minimum size of 30 × 39.5 × t 0.3 mm 1.181 × 1.555 × t 0.012 in ( **GXL-15HLU** type: 30 × 30 × t 0.3 mm 1.181 × 1.181 × t 0.012 in), should be inserted between the sensor and the magnetic body. However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator. - 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. - The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. - 4) It is the leakage current when the output is in the OFF state. - 5) The maximum load current varies with the ambient temperature. Refer to “ **I/O CIRCUIT AND WIRING DIAGRAMS** (p.828)” for more details. - 6) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V. - 7) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand. - 8) The flexible cable type (model No. with suffix “ **-R** ”) has a 0.15 mm[2] ( **GXL-15** type: 0.2 mm[2] ) flexible, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long. DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 828 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX** ## **I/O CIRCUIT AND WIRING DIAGRAMS** ## **DC 2-wire type** ## **GXL-8 type** ## **I/O circuit diagram** **==> picture [230 x 393] intentionally omitted <==** **----- Start of picture text -----**<br> Color code<br>Bleeder resistance<br>(Brown)<br>Output Load<br>3 to 70 mA in ON state (Note)<br>Tr ZD 0.8 mA in OFF state + 12 to 24 V DC<br>3 V in ON state – ±10 %<br>Load<br>(Blue) 0 V<br>Internal circuit Users’ circuit<br>Symbols … ZD: Surge absorption zener diode<br>Tr : PNP output transistor<br>Note: The maximum load current varies depending on the ambient<br>temperature.<br>70<br>35<br>3<br>–25 +55 +70<br>–13 +131 +158<br>Ambient temperature (°C °F)<br>GXL-15 type<br>I/O circuit diagram<br>Color code<br>Bleeder resistance<br>(Brown)<br>Output Load<br>3 to 100 mA in ON state (Note)<br>Tr ZD 0.8 mA in OFF state + 12 to 24 V DC<br>3 V in ON state – ±10 %<br>Load<br>(Blue) 0 V<br>Internal circuit Users’ circuit<br>Sensor circuit<br>Max. load current (mA)<br>Sensor circuit<br>**----- End of picture text -----**<br> ## **Wiring diagram** **==> picture [246 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> Bleeder resistance<br>Brown<br>Load<br>+ 12 to 24 V DC<br>– ±10 %<br>Blue<br>Load<br>**----- End of picture text -----**<br> ## **Conditions for the load** - 1) The load should not be actuated by the leakage current (0.8 mA) in the OFF state. - 2) The load should be actuated by (supply voltage – 3 V) in the ON state. 3) The current in the ON state should be between 3 to 70 mA DC. In case the current is less than 3 mA, connect a bleeder resistance in parallel to the load so that a current of 3 mA, or more, flows. ## **Wiring diagram** **==> picture [236 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> Bleeder resistance<br>Brown<br>Load<br>+ 12 to 24 V DC<br>– ±10 %<br>Blue<br>Load<br>**----- End of picture text -----**<br> Symbols … ZD: Surge absorption zener diode Tr : PNP output transistor ## **Conditions for the load** **==> picture [208 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> Note: The maximum load current varies depending on the ambient<br>temperature.<br>100<br>50<br>3<br>–25 +55 +70<br>–13 +131 +158<br>Ambient temperature (°C °F)<br>Max. load current (mA)<br>**----- End of picture text -----**<br> - 1) The load should not be actuated by the leakage current (0.8 mA) in the OFF state. - 2) The load should be actuated by (supply voltage – 3 V) in the ON state. - 3) The current in the ON state should be between 3 to 100 mA DC. - In case the current is less than 3 mA, connect a bleeder resistance in parallel to the load so that a current of 3 mA, or more, flows. DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 829 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL** **GL** **GX-M GX-U/GX-FU/ GX-N GX** ## **SENSING CHARACTERISTICS (TYPICAL)** ## **GXL-8 type** **Sensing field (common)** **Correlation between sensing object size and sensing range (DC 2-wire type)** **Correlation between sensing object size and sensing range (NPN output type)** **==> picture [506 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 0.1574 Standard sensing object Iron sheet 15 × 15 × t 1 mm0.591 × 0.591 × t 0.039 in Standard sensing objectIron sheet 15 × 15 × t 1 mm0.591 × 0.591 × t 0.039 in 0.157 4 a × a mm Sensing object t 1 mm a × a in Sensing object a × a mm t 1 mm a × a in 0.157 4 a × a mm Sensing object t 1 mm a × a in Sensing object a × a mm t 1 mm a × a in As the sensing object size becomes smaller than the<br>3 ℓ L ℓ L 3 L t 0.039 in L t 0.039 in 3 L t 0.039 in L t 0.039 in standard size (iron sheet 15 × 15<br>0.118 Front sensing Top sensing 0.118 Front sensing Top sensing Stainless steel Iron 0.118 Front sensing Top sensing Stainless steel Iron × t 1 mm in), the sensing range shortens as 0.591 × 0.591 × t 0.039<br>2 2 (SUS304) 2 (SUS304) shown in the left figures.<br>0.079 0.079 Brass 0.079<br>Aluminum Brass<br>1 1 1 Aluminum<br>0.039 0.039 0.039<br>0<br>10 5 0 5 10 0 5 10 15 20 0 5 10 15 20<br>0.394 0.197 0.197 0.394 0.197 0.394 0.591 0.787 0.197 0.394 0.591 0.787<br>Left Center Right Sensing object side Sensing object side<br>Operating point ℓ (mm in) length a (mm in) length a (mm in)<br>)in ) in ) in<br>Setting distance L (mm Sensing range L (mm Sensing range L (mm<br>**----- End of picture text -----**<br> ## **GXL-15 (Standard) type** **Sensing field** **Correlation between sensing object size and sensing range** **==> picture [250 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 0.3158 Standard sensing object Iron sheet 20 × 20 × t 1 mm Iron sheet 20 × 20 × t 1 mmStandard sensing object 0.3158 Sensing object<br>0.787 × 0.787 × t 0.039 in 0.787 × 0.787 × t 0.039 in a × a mm a × a in<br>ℓ ℓ<br>0.2366 L L 0.2366 L t 1 mm Front sensingt 0.039 in Iron<br>Front sensing Stainless steel<br>4 4 (SUS304)<br>0.157 Top sensing 0.157<br>Brass<br>2 2 L t 1 mmt 0.039 in Aluminum<br>0.079 0.079 Top sensing Sensing objecta × a mm a × a in<br>0<br>10 5 0 5 10 0 10 20 30 40<br>0.394 0.197 0.197 0.394 0.394 0.787 1.181 1.575<br>Left Center Right Sensing object side<br>Operating point ℓ (mm in) length a (mm in)<br>)Setting distance L (mm in )Sensing range L (mm in<br>**----- End of picture text -----**<br> As the sensing object size becomes smaller than the standard size (iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in), the sensing range shortens as shown in the left figure. ## **GXL-15 (Long sensing range) type** **Sensing field** **Correlation between sensing object size and sensing range** **==> picture [249 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> Standard sensing object Standard sensing object<br>Iron sheet 30 × 30 × t 1 mm Iron sheet 30 × 30 × t 1 mm Sensing object<br>1.181 × 1.181 × t 0.039 in 1.181 × 1.181 × t 0.039 in a × a mm a × a in<br>10 ℓ ℓ 10 t 1 mm<br>0.394 L L 0.394 L t 0.039 in<br>Top sensing Iron<br>Front sensing Stainless steel<br>(SUS304)<br>0.1975 Top sensing 0.1975 Brass<br>t 1 mm Aluminum<br>L t 0.039 in<br>Sensing object<br>Front sensing a × a mm a × a in<br>0<br>10 5 0 5 10 0 10 20 30 40<br>0.394 0.197 0.197 0.394 0.394 0.787 1.181 1.575<br>Left Center Right Sensing object side<br>Operating point ℓ (mm in) length a (mm in)<br>As the sensing object size becomes smaller than the standard<br>size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the<br>sensing range shortens as shown in the left figure.<br>)in<br>)in<br>Setting distance L (mm<br>Sensing range L (mm<br>**----- End of picture text -----**<br> ## **PRECAUTIONS FOR PROPER USE** Refer to p.1485~ for general precautions. - Never use this product as a sensing device for personnel protection. - In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. ## **Mounting** ## **GXL-8 type** - The tightening torque should M3 (length 12 mm 0.472 in) truss head screw (Accessory) - be 0.5 N·m or less. - • To mount the sensor with a nut, the **MS-GXL8-4** (Accessory) thru-hole diameter should be ø3.4 mm ø0.134 in. With the M3 × 0.5 mm 0.020 in tapped hole (Depth: 8 mm 0.315 in or more) - attached mounting screw and nut, or ø3.4 mm ø0.134 in thru-hole take care that the thickness of the mounting plate should be 2.3 mm 11.5 mm 0.453 in 0.091 in or less. If mounting using nut and washers - • If a screw other than the attached (Accessories) screw is used, make sure to use a ø2.4 mm ø0.094 in hole M3 truss head screw. (Depth: 3 mm 0.118 in or more) Do not use a flat head screw or a pan head screw. ## **GXL-15 type** **==> picture [242 x 276] intentionally omitted <==** **----- Start of picture text -----**<br> • The tightening torque should be 1 N·m or M3 pan head screw or truss head screw<br>less. Do not use a<br>( flat head screw )<br>• To mount the sensor with the optional sensor<br>mounting bracket MS-GXL15 , the thru-hole M3 × 0.5 mm 0.020 in tapped hole<br>or ø3.4 mm ø0.134 in thru-hole<br>diameter should be ø3.4 mm ø0.134 in.<br>• Screw, nut or washers are not supplied. 9 mm<br>0.354 in<br>Please arrange them separately.<br>• To mount the long sensing range type on a If mounting using nut and washers.<br>magnetic body, such as iron, the enclosed When mounting using<br>aluminum sheet, or any other aluminum MS-GXL15 (Optional)<br>sheet having a minimum size of 30 × 39.5<br>× t 0.3 mm 1.181 × 1.555 × t 0.012 in<br>( GXL-15HLU type: 30 × 30 × t 0.3 mm 1.181 Aluminum sheet<br>× 1.181 × t 0.012 in), should be inserted<br>between the sensor and the magnetic body.<br>However, it is not necessary to use the<br>aluminum sheet when mounting on a non- Sensor<br>mounting<br>magnetic body, such as, aluminum or an bracket’s<br>insulator. mounting holes<br>• When mounting the inductive proximity sensor with the optional sensor mounting GXL-15F<br>bracket MS-GXL15-2 , if the bracket is Sensor’s<br>mounted close to the sensing part, the mounting holes<br>bracket itself gets sensed and the operation MS-GXL15-2<br>becomes unstable. Make sure to mount such ( Optional sensor mounting bracket )<br>that the mounting holes of the sensor and<br>those of the mounting bracket are in one horizontal straight line.<br>**----- End of picture text -----**<br> DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 830 Refer to p.1485~ for general precautions. FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX** ## **PRECAUTIONS FOR PROPER USE** ## **Influence of surrounding metal** - When there is a metal near the sensor, keep the minimum separation distance specified below. ## **Front sensing type** **==> picture [240 x 234] intentionally omitted <==** **----- Start of picture text -----**<br> Metal<br>C<br>B C<br>Metal<br>A<br>GXL-8F type GXL-15FU type GXL-15FLU type<br>A 7 mm 0.276 in 8 mm 0.315 in 8 mm 0.315 in (Note)<br>B 8 mm 0.315 in 20 mm 0.787 in 30 mm 1.181 in<br>C 3 mm 0.118 in 7 mm 0.276 in 10 mm 0.394 in<br>Note: The GXL-15FLU type should be mounted on an insulator or a non-magnetic body.<br>To mount it on a magnetic body, such as iron, use the enclosed aluminum sheet.<br>Top sensing type<br>Metal<br>D<br>Metal Metal<br>G<br>E F G<br>**----- End of picture text -----**<br> **==> picture [240 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> GXL-8H type GXL-15HU type GXL-15HLU type<br>D 4 mm 0.157 in 6 mm 0.236 in 12 mm 0.472 in<br>E 10 mm 0.394 in 20 mm 0.787 in 30 mm 1.181 in<br>F 3 mm 0.118 in 0 mm 0 in 10 mm 0.394 in (Note)<br>G 3 mm 0.118 in 3 mm 0.118 in 10 mm 0.394 in<br>**----- End of picture text -----**<br> Note: When **GXL-15HLU** type is mounted on an insulator or a non-magnetic body, or seated on the enclosed aluminum sheet, the distance “F” can be zero. ## **Mutual interference prevention** - When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. **==> picture [239 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> H J Front sensing<br>Between “ I ” type 0 mm 15 mm<br>GXL-8 and non “ I ” type (Note 2) 0.591 in<br>type Between two “ I ” types 18 mm 30 mm<br>or two non “ I ” types 0.709 in 1.181 in<br>GXL-15FU Between “and non “ II ” t” typeype (Note 20 mm ) 0.984 in25 mm J<br>GXL-15HU type Between two “or two non “ I ” t I yp” typeses 1.181 in30 mm 2.362 in60 mm H H<br>GXL-15FLU Between “and non “ II ” t” typeype (Note 20 mm ) 0.984 in25 mm<br>GXL-15HLU<br>type Between two “or two non “ I ” t I yp” typeses 2.953 in75 mm 3.543 in90 mm<br>Notes: 1) “ I ” in the model No. specifies the<br>different frequency type. Top sensing<br>**----- End of picture text -----**<br> - 2) Close mounting is possible for up to two sensors. - When mounting three sensors or more at an equal spacing, align the model with “ **I** ” and the model without “ **I** ” alternately. H J - The minimum value of dimension “H” should be as given below. **GXL-8** type: 5 mm 0.1975 in, **GXL-15FU/15HU** type: 7.5 mm 0.295 in, **GXL-15FLU/15HLU** type: 30 mm 1.181 in **==> picture [34 x 38] intentionally omitted <==** ## **Sensing range** - The sensing range is specified for the standard sensing object. With a non-ferrous metal, the sensing range is obtained by multiplying with the correction coefficient specified below. Further, the sensing range also changes if the sensing object is smaller than the standard sensing object or if the sensing object is plated. ## **Correction coefficient** **==> picture [240 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> Model GXL-15HU<br>No. GXL-8 GXL-15FU GXL-15FLU<br>type type GXL-15HLU<br>Metal type<br>Iron 1 1 1<br>Stainless steel<br>(SUS304) 0.82 approx. 0.74 approx. 0.75 approx.<br>Brass 0.59 approx. 0.53 approx. 0.53 approx.<br>Aluminum 0.57 approx. 0.52 approx. 0.51 approx.<br>**----- End of picture text -----**<br> ## **Others** - Do not use during the initial transient time (50 ms) after the power supply is switched on. ## **Wiring** - The sensor must be connected to a power supply via a load. If the sensor is connected to a power supply without a load, the short-circuit protection makes the sensor inoperable. (The output stays in the OFF state and the indicator does not light up.) In this case, rectify by connecting the power supply via a load. Now, the sensor becomes operable. Further, take care that if the power supply is connected with reverse polarity without a load, the sensor will get damaged. **==> picture [162 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> Blue lead wire Brown lead wire<br>+ DC + DC<br>– power – power<br>supply supply<br>Brown lead wire Blue lead wire<br>**----- End of picture text -----**<br> - For series connection (AND circuit) or parallel connection (OR circuit) of sensors, take care of the following. ## **Series connection (AND circuit) Parallel connection (OR circuit)** When all sensors are When all sensors are in the in the ON state, the OFF state, the load leakage ~~L~~ oad load voltageVRL is given by: Load current Icc is given by:Icc = n × 0.8 (mA) VRL VRL = Vcc – n × 3 (V) Icc (n : number of sensors)Make sure that the load +– Vcc Vcc: supply voltage( 24 V DC max.) (I+ L) Vcc can work properly.Note : The load current in the n: number of sensors – ON state is given by : Make sure that the load IL = Load resistanceVcc – 3 V (mA) can work properly at **GXL-8 type** : this voltage. 3 mA × n ≤ lL ≤ 70 mA Note: The output is generated ( n: number of sensors turned ON ) normally even if the indicator **GXL-15 type** : does not light up properly. ( 3 mA × n ≤ ln: number of sensors turned ONL ≤ 100 mA) - The residual voltage of the sensor is 3 V. Before connecting a relay at the load, take care of its actuation voltage. (Some 12 V relays may not be usable.) **==> picture [199 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> Relay actuation<br>voltage:<br>VR Relay actuation VR ≤ 12 – 3V<br>(voltage ) ≤ 9V<br>+ 12 V DC<br>Brown lead wire – power supply<br>VS = 3 V Residual voltage<br>when the sensor<br>( is in the ON state)<br>Blue lead wire<br>Relay<br>**----- End of picture text -----**<br> DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 831 Refer to p.1485~ for general precautions. FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVINGUNITS UNITS ## **PRECAUTIONS FOR PROPER USE** ## **Use conditions to comply with CE Marking** • Following work must be done in case of using this product as a CE Marking (European standard EMC Directive)conforming product. ## Ensure that the shield is connected to 0 V. **==> picture [228 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> Shield (piping, etc.) 0 V<br>Power supply<br>Sensor /<br>OUT Load<br>**----- End of picture text -----**<br> Note: The shield (piping, etc.) must be insulated. ## **DIMENSIONS (Unit: mm in)** The CAD data in the dimensions can be downloaded from our website. **==> picture [547 x 448] intentionally omitted <==** **----- Start of picture text -----**<br> SIMPLE<br>WIRE-SAVINGUNITS GXL-8FU type Sensor GXL-8HU type Sensor<br>WIRE-SAVING ø3 ø0.118<br>SYSTEMS 2-color indicator (Red, green) mounting hole<br>MEASURE-MENT ( Only red LED for normally closed type ) 0.197 5 4 0.157 ø2.9 1 m 3.281 ft ø0.114 cable,long<br>SENSORS 8<br>ELECTRICITYPREVENTIONMARKERSDEVICESLASERSTATIC (0.039) (1) 0.315 0.291 7.4 4 0.157 0.205 5.2 0.291 7.4 3.3 0.130 direction Sensing 0.413 10.5 0.197 5 0.217 5.5<br>18.5 (4.5)<br>PLC 0.291 7.4 direction Sensing 0.268 6.8 0.728 1.4 0.055 (0.177)<br>21 20 11.5 4 2-color indicator (Red,green)<br>MACHINE HUMAN 0.827 0.787 0.453 GXL-8FU 0.291 7.4 0.157 (Only red LED for normally closed type) 4<br>INTERFACES 7.3 0.157<br>VISUALIZATION CONSUMPTION COMPONENTSENERGY 3 0.118 0.177 4.5 ø3 ø0.118 0.287 0.315 8 0.181 4.6 0.362 9.2 0.209 5.3<br>mounting hole<br>COMPONENTSFA 5 ø2.9 1 m 3.281 ftø0.114 longcable, 4 2.6 0.102 0.291 7.4 3 2 0.079 0.102 2.6<br>SYSTEMSMACHINE VISION 0.197 0.217 5.5 0.157 0.209 5.3 0.315 8 0.118 0.906 23 3 0.118<br>UV<br>CURING<br>SYSTEMS<br>GXL-15F type Sensor GXL-15H type Sensor<br>8 2-ø3.2 ø0.126<br>0.315 11 mounting holes<br>0.433<br>5 ø3 ø0.118 cable,<br>Selection Guide 0.197 1 m 3.281 ft long<br>Amplifier 15 2-color indicator (Note)<br>Built-in 0.591 (Red, green) Sensing ø5.4 9<br>seAmplifier-parated 0.567 14.4 2.8 0.110 direction ø0.213 0.354<br>Sensing<br>7.5 direction<br>GX-F/H 0.295 0.567 14.4 1.024 26 (4) (0.157)<br>21<br>GXL 0.827<br>GX-MGL 1.378 35 1.260 32 0.807 20.5 GXL-15F 13 0.567 0.591 14.4 15 0.472 0.492 12.5 12 2-color indicator (Note) (Red, green)<br>0.512<br>GX-U/GX-FU/GXGX-N 0.118 3 0.157 4 ø3 1 m 7 ø0.1182-ø3.2 mounting holes 3.281 ft cable, ø0.126 long 2.8 0.567 14.4 0.335 8.5 0.630 16 16.50.650 0.264 6.7 0.303 7.7 0.311 7.9 0.350 8.9<br>9 0.276 5.7 0.110<br>0.354 0.224 30 3<br>1.181 0.118<br>GXL-8HU<br>GXL-15H<br>**----- End of picture text -----**<br> Note: Normally closed type have an operation indicator (red) instead of the 2-color indicator. Note: Normally closed type have an operation indicator (red) instead of the 2-color indicator. DC 2-wire type Micro-size Inductive Proximity Sensor **GXL SERIES** 832 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX** ## **DIMENSIONS (Unit: mm in)** ## **MS-GXL8-4** Sensor mounting bracket for **GXL-8FU** / **GXL-8HU** type (Accessory) ## **Mounting hole dimensions** **==> picture [235 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> (9.0)<br>(0.354) Center of ø2.4 ø0.094 hole,<br>2.3 0.0792 0.0792 sensing 3 0.118 or more deep<br>0.091<br>0.3<br>0.012 t 0.4 M3 × 0.5 0.020<br>(16.2) 15.8 3.3 (0.453)(11.5) t 0.016 0.45311.5 tapped hole, 8 0.315 or more deep<br>(0.638) 0.622 0.130<br>4.5 0.177<br>ø3.1 ø0.122 hole<br>**----- End of picture text -----**<br> The CAD data in the dimensions can be downloaded from our website. **==> picture [188 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Sensor mounting bracket for GXL-15 type (Optional)<br>**----- End of picture text -----**<br> ## **MS-GXL15** **==> picture [75 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> t 2<br>t 0.079<br>14<br>0.551<br>9 2.5<br>0.354 0.098<br>7 0.276<br>2-M3 × 0.5 0.020<br>tapped hole<br>**----- End of picture text -----**<br> **==> picture [111 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Material: Cold rolled carbon steel (SPCC)<br>**----- End of picture text -----**<br> Material: Stainless steel (SUS304) 1 pc. each of M3 (length 12 mm 0.472 in) truss head screw, nut, spring washer and plain washer is attached. ## **MS-GXL15-2** ## Sensor mounting bracket for **GXL-15F** type (Optional) ## **MS-A15F MS-A15H** ## Aluminum sheet (Accessory for **GXL-15FLU / GXL-15HLU** type) **==> picture [139 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 30<br>1.181<br>3.2 24<br>0.126 0.945<br>8<br>0.315<br>4<br>0.157<br>16.5 1.2<br>0.650 0.047<br>6.6<br>0.260<br>t 0.5 Fixed rubber<br>t 0.020<br>**----- End of picture text -----**<br> Material: Bracket ... Stainless steel (SUS304) Fixed rubber ... FKM (Fluorine rubber) **==> picture [205 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> 30<br>1.181<br>2-ø3.2<br>ø0.126<br>2-3.2 × 5.1<br>0.126 × 0.201 39.5<br>oblong holes 1.555 [(] [MS-A15H] [: 30 ][1.181][)]<br>4 0.157<br>9 t = 0.3 0.012<br>0.354<br>1.9 21 1.9<br>0.075 0.827 0.075<br>**----- End of picture text -----**<br>
Updated at April 21, 2026
Panasonic Industry is a global leader in the design and manufacture of high-quality electronic components. Renowned for a commitment to continuous innovation, the company provides the essential building blocks that empower modern engineering. From industrial automation to consumer electronics, Panasonic's components are trusted worldwide for their outstanding reliability, efficiency, and long-term performance. The extensive portfolio is anchored by a massive selection of passive components, featuring an industry-leading range of aluminium electrolytic, film, and polymer capacitors. Alongside these advanced capacitance solutions, engineers rely on Panasonic's robust power inductors and a highly versatile array of electromechanical devices, including solid-state, power, and signal relays engineered to excel in demanding environments. Beyond core passives and switching solutions, the offering encompasses critical circuit protection devices such as TVS varistors and NTC thermistors, as well as sophisticated thermal management materials. Panasonic also delivers precision light and motion sensors, highly reliable batteries, and advanced Bluetooth and WLAN connectivity modules, providing a comprehensive ecosystem of components to support next-generation technological design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →