GXE600-48/A
AC/DC Enclosed Power Supply (PSU), ITE & Medical, 1 Outputs, 600 W, 48 VDC, 12.5 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: GXE600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Output Type: Programmable
- Output Current - Output 1: 12.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 530.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
GXE600 Series ## Single Output 600W Programmable Medical and Industrial Power Supplies https://product.tdk.com/en/power/gxe www.emea.lambda.tdk.com/gxe600 With efficiencies up to 95%, the medical and industrial certified GXE600 is rated at 600W with convection cooling for low audible noise. The output voltage and current can be programmed and set for constant current or constant voltage characteristics. The Modbus RTU serial protocol is used for data transmission due its high interference immunity within noisy industrial environments. The parameters for fault programming (protection level and recovery characteristics) and the slew rate timing can be changed. Remaining electrolytic capacitor life, operating hours and alarm history can be read through the RS-485 interface, aiding remote preventative maintenance. As standard the GXE600 has a 5V 1A standby voltage, isolated DC Good and AC Fail signals, remote on/off and paralleling capability for up to five units. |**Features**|**Benefits**| |---|---| |• Convection Cooled|• Quiet Operation| |• Up to 95% Efficient|• Lower Operating Costs| |• RS-485 Read-Write Communication (Modbus RTU protocol)|• Applicable for Communication in Industrial Applications| |• Constant Voltage & Constant Current Modes|• Versatile Use| |• Monitoring & Programming Functions|• Allows Remote Monitoring and Operation| |• Digital or Analog Programming|• Easier System Integration| |• Seven Year Warranty(1)|• Low Cost of Ownership| |**Model Selector**|**Model Selector**||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||Nominal Output<br>Output Adjustment||||||Output Adjustment|||Maximum|Maximum|Efficiency|| |Model|Voltage|||Manual|||Programming(2)|||Current|Power|(typ %)|| ||(V)|||(V)||||(V)||(A)|(W)|115 / 230Vac|| |GXE600-24|24||19.2 - 28.8||||4.8 - 28.8|||25|600|92 / 95|| |GXE600-48|48||38.4 - 57.6||||9.6 - 57.6|||12.5|600|92 / 95|| ||||||||||||||| |**GXE600-**|||**24**|||**/**||||**A**|||| ||||||||||||||| ||||Output voltage 24, 48|||||blank|U channel chassis|U channel chassis|||| |||||||||/A|U channel chassis with cover|U channel chassis with cover|||| |||||||||/HD|U channel chassis, ruggedized & pcb coating|U channel chassis, ruggedized & pcb coating|||| |||||||||/HDA|U channel chassis with cover, ruggedized & pcb coating|U channel chassis with cover, ruggedized & pcb coating||U channel chassis with cover, ruggedized & pcb coating|| GXE600 Series 1 **==> picture [517 x 34] intentionally omitted <==** ## **Specifications** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>GXE600-24|||GXE600-48| |**Input**|||| |Input Voltage Range(3)(Operating)|Vac|85 - 265. Withstands 300 for 5s<br>|| |Nominal Input Voltage Range|Vac|100 - 240 (Note: Safety certifed for 90-264Vac)|| |Input Frequency|Hz|47 - 63|| |Input Current (typ) (115/230Vac)|A|6.1 / 3.1|| |Inrush Current (typ 100/200Vac) (Cold Start)|A|40 / 40|| |Leakage Current (Maximum)|mA|<0.3|| |Power Factor (115/230Vac)|-|0.99 / 0.95|| |Harmonic Compliance|-|Meets EN61000-3-2|| |No Load Power Consumption|W|3.4 at 100Vac. 1.2 at 200Vac when remote on/off is activated and no load on 5Vsb|| |Hold Up Time (typ) at 115 / 230Vac Input<br>|ms|20|| |Effciency|-|See model selector|| |Conducted & Radiated EMI|-|EN55011-B, EN55032-B, FCC Class B|| |Immunity|-|IEC61000-4-2, IEC60601-1-2 Ed4. See immunity table|| |Insulation Class|-|Class I|| |Safety Certifcations and Markings|-|IEC/UL/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, 60950-1, CE Mark and UKCA Mark|| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|<br>Notes| |ESD|EN61000-4-2|Air ±8kV and contact ±4kV|A|See website for immunity test report| |Radiated Susceptibility|EN61000-4-3|80M -1GHz: 10V/m<br>1.4 - 2.0GHz: 3V/m<br>2.0 - 2.7GHz: 1V/m|A|| |Electrical Fast Transient Burst|EN61000-4-4|± 2kV|A|| |Surge|EN61000-4-5|Normal ± 1kV|A|| |Conducted Susceptibility|EN61000-4-6|10Vrms|A|| |Magnetic Fields|EN61000-4-8|30A/m|A|| |Voltage Dips|EN61000-4-11|30% 500ms|A|| |Voltage Dips|EN60601-1-2|30% 500ms|A|| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200Vac| ## **Specifications** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>GXE600-24|||GXE600-48| |**Output**|||| |Switching Frequency|kHz|134, PFC 100|| |Line Regulation|mV|96|192| |Load Regulation|mV|144|288| |External Load Capacitance|uF|10,000|| |Ripple & Noise<br>|mV|150|350| |Temperature Coeffcient|%/°C|<0.02%/°C|| |Minimum Load|-|No minimum load required|| |Overcurrent Protection (Factory Set)|A|>27.5|>13.8| |Overcurrent Protection (Via Programming)(2,4)|A|5 - 28.8|2.5 - 14.4| |Overvoltage Protection (Via Programming)(4)|V|28.8 - 31.2|57.6 - 62.4| |Remote Sense|-|Yes<br>|| |Remote On/Off|-|Isolated opto-coupler. Unit off when current is fowing through the opto diode|| |Power Fail Signal|-|Signal is high when the output voltage drops due to AC loss or OCP, OVP, OTP|| |AC Fail Signal|-|Signal goes high when the AC input is not present|| |Standby Voltage|V / A|4.8V - 5.2V 1A|| |Indicators|-|DC OK<br>|| |Parallel Operation|-|Up to fve units|| GXE600 Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>GXE600-24|||GXE600-48| |**Environmental**|||| |Operating Temperature|°C|-20 to +70. Derate linearly to 50% load from +50 to +70(5)|| |Storage Temperature|°C|-40 to +85|| |Humidity (non condensing)|%RH|Operating: 20 - 90 Storage: 10 - 90|| |Pollution Degree|-|PD 2|| |Cooling|-|Convection or Forced Air Cooled|| |Altitude|m|5000 (IEC 62368-1), 4000 (IEC 60601-1)|| |Withstand Voltage (For 1 minute)|Vac|Input to Ground 2,000 (1xMOPP), Input to Output 4,000 (2xMOPPs), Output to Ground 1,500 (1xMOPP)|| |Isolation Resistance|MΩ|>100 at 25°C, 70%RH & 500Vdc|| |Vibration (Non Operating)|-|10 - 55Hz: 19.6m/s2constant sweep 1 min X, Y, Z for 1 hour<br>/HD version: Designed to meet MIL-STD-810G 514.7 Category 4, 10|| |Shock|-|< 196.1 m/s2, /HD version: Designed to meet MIL-STD-810G 516.7 Procedure I, VI|| |**Other**|||| |Weight (Typ)|g|1300, 1400 with cover|| |Size (LxWxH)|mm|254 x 127 x 41, /A model 254 x 127.5 x 50|| |Size (LxWxH)|Inches|<br>10 x 5 x 1.61, /A model: 10 x 5.02 x 1.97|| |Case Material|-|Aluminum|| |Connectors|-|Screw Terminals. See detailed outline drawings on website for signal connectors|| |MTBF - Telcordia SR-332 issue 3*|Hours|511,677|| |Warranty|Years|7(1)|| Notes See website for detailed specifcations, test methods and installation manual (1) The Americas and EMEA regions: 7 years. Other regions: 5 years. See applicable regional terms of sale. (2) Using RS-485 communications or external 1-6V voltage source. See installation manual for details (3) 85Vac: 360W, 100 to <170Vac: 500W, 170V to 265Vac: 600W (Convection cooled). 600W when forced air is applied (see installation manual) (4) Overcurrent & Overvoltage limits and recovery modes can be set using the RS-485 communications (5) Models with cover (/A option) have additional derating. See derating curves in the instruction manual *24V output model, 25°C ambient, full load, 230Vac input ## **Monitoring and Programming Functions** |**Monitoring and Programming Functions**|**Monitoring and Programming Functions**|**Monitoring and Programming Functions**| |---|---|---| |Function|Digital (RS-485) Control|Analog Control| |Output Voltage Monitor|Read back|No| |Output Current Monitor|Read back|No| |Output Voltage Programming|Adjustable|Adjustable, use a 1-6V external voltage source| |Output Current Programming|Adjustable|Adjustable, use a 1-6V external voltage source| |Over Voltage Protection Set Point|Adjustable|Fixed| |Over Voltage Recovery|Auto-recovery or manual settings|Cycle AC input or use the remote on/off| |Over Current Set Point|Adjustable|Fixed| |Over Current Recovery|Auto recovery: Constant current, hiccup or foldback<br>Latching: Constant current or foldback|Constant current, auto-recovery| |Over Temperature Recovery|Cycle AC input or use the remote on/off|Cycle AC input or use the remote on/off| |Remote On/Off|Yes, enable or inhibit type|Yes, enable or inhibit type| |Internal Temperature Monitoring|Yes, -20 to +100°C|No| |Operating Run Time Log|Records more than 20 years of data|No| |Remaining Electrolytic Capacitor Life|Indicates hours left|No| |Alarm History|OCP, OVP, OTP, remote on/off, system error|No| |Slew Rate (Rise-time) Control<br>|Voltage and current|No| |Communication Confguration|ID, Baud Rate, Parity<br>|Not applicable| |Product Information|Model #, serial #, lot #, frmware version|Not applicable| |Power Fail Signal Threshold|Adjustable for either output voltage or current|Fixed (voltage only)| GXE600 Series 3 **==> picture [124 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Outline Drawing GXE600<br>**----- End of picture text -----**<br> ## **Outline Drawing GXE600/A** GXE600 Series 4 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **Italy Sales Office** Tel: +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Germany GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **Nordic Sales Office** ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com Tel: +45 8853 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ GXE600_260937 March 26th, 2024 V2 GXE600 Series 5
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →