GX-5M
Inductive Proximity Sensor, Cylindrical, GX Series, Compact, M5, 0.8 mm, SPST-NO, 12 to 24 V, Cable
- Manufacturer: PANASONIC
- Product type: Inductive Proximity Sensors
- Product Range: GX Series
- Sensor Output: NPN-NO
- Sensing Range Max: 0.8mm
- Thread Size - Metric: M5
- Supply Voltage DC Max: 24V
- Supply Voltage DC Min: 12V
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 70.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in **GX SERIES**
865
**■** General terms and conditions ............. F-7 **■** Sensor selection guide ................. P.803~ FIBER Related Information SENSORS **■** Glossary of terms........................ P.1482~ **■** General precautions ................... P.1485~ ~~oe~~ LASER ~~[i~~ SENSORS PHOTOELECTRIC SENSORS Conforming to ~~—~~ MICRO EMC Directive PHOTOELECTRIC SENSORS AREA SENSORS ~~-~~ LIGHT CURTAINS / ~~/~~ SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS ~~—~~ MEASUREMENTSENSORS —— **panasonic.net/id/pidsx/global** Flexible cable Metal embedding type available possible STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS **Robust enclosure and flexible cable**
PLC
HUMAN MACHINE INTERFACES **VARIETIES** ~~C—O~~ ENERGY CONSUMPTION VISUALIZATION COMPONENTS **Miniature GX-3S□ Robust housing GX-4S□** FA COMPONENTS **GX-3S□** is an amplifier built-in inductive proximity sensor The **GX-4S□** uses a robust stainless steel enclosure. having a diameter of just ø3.8 mm ø0.150 in. The tightening torque can be 0.58 N·m or less. MACHINE VISION SYSTEMS (2 times compared with conventional models) UV CURING SYSTEMS Tightening torque: **0.58 N·m or less**
Selection Guide Amplifier ~~—~~ Built-in Amplifier- ~~—~~ separated **GX-F/H** ~~.~~ **GXL** ~~—~~ **GL GX-M GX-U/GX-FU/ GX-N GX** ~~LLL~~
**==> picture [115 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conforming to Recognition<br>EMC Directive Excluding GX-4S□ and<br>5 m cable length type<br>Flexible cable Metal embedding<br>type available possible<br>**----- End of picture text -----**<br>
## WIRE-SAVING SYSTEMS ~~—~~ MEASUREMENTSENSORS —— **panasonic.net/id/pidsx/global** Flexible cable
## **Robust enclosure and flexible cable types are also available**
Set screw M3(Cup-point) [> ye Robust enclosure [Stainless steel (SUS304)] [ø4.4 ø0.173 (length: 30 mm 1.181 in)] Operation indicator (Red) Tighten the set screw from a direction perpendicular to the operation indicator. — Set screw tightening position Je {! A: 5 to 10 mm 0.197 to 0.394 in from the sensor end
_ ø3.8 mm ø0.150 in
## rrr **BASIC PERFORMANCE** ETT eee **ENVIRONMENTAL RESISTANCE Long sensing range** ~~|~~ **GX-8ML□ Ten times greater bending durability**
## **Ten times greater bending durability** (Compared with conventional models) **GX-□-R**
The non-shielded type ( **GX-8ML□** ) has twice the sensing range of the shielded type ( **GX-8M□** ), although having the same size. Hence, it allows margin against sensing distance variations.
The bending durability of the cable to repeated bending has been increased tenfold by using special alloy cores for the cable.
**==> picture [103 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shielded type<br>GX-8M□ 1 mm<br>0.039 in<br>Non-shielded type<br>GX-8ML□ 0.079 in2 mm<br>**----- End of picture text -----**<br>
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
866
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **APPLICATIONS**
**==> picture [166 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sensing screws on cassette<br>**----- End of picture text -----**<br>
**==> picture [336 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sensing the punch of a die Counting parts<br>**----- End of picture text -----**<br>
## **ORDER GUIDE**
**==> picture [504 x 398] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Appearance(mm in) Sensing range (Note) Model No. Supply voltage Output Outputoperation<br>Maximum operation distance<br>ø3.8 0.8 mm 0.031 in GX-3S Normally open<br>ø0.150<br>30<br>1.181 (0 to 0.6 mm 0 to 0.024 in)<br>Stable sensing range GX-3SB Normally closed<br>12 to 24 V DC<br>Robust enclosure type ±10 %<br>0.8 mm 0.031 in GX-4S Normally open<br>ø4.4<br>ø0.173<br>301.181 (0 to 0.6 mm 0 to 0.024 in) GX-4SB Normally closed<br>ø5.4 1 mm 0.039 in GX-5S Normally open<br>ø0.213<br>10 to 30 V DC<br>30<br>1.181 (0 to 0.8 mm 0 to 0.031 in)<br>GX-5SB Normally closed<br>NPN<br>open-collector<br>transistor<br>M5 0.8 mm 0.031 in GX-5M Normally open<br>12 to 24 V DC<br>30 ±10 %<br>1.181 (0 to 0.6 mm 0 to 0.024 in) GX-5MB Normally closed<br>M8 1 mm 0.039 in GX-8M Normally open<br>301.181 (0 to 0.8 mm 0 to 0.031 in) GX-8MB Normally closed<br>10 to 30 V DC<br>M8 2 mm 0.079 in GX-8ML Normally open<br>30<br>1.181 (0 to 1.6 mm 0 to 0.063 in)<br>GX-8MLB Normally closed<br>Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.<br>The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient<br>temperature drift and/or supply voltage fluctuation.<br>Non-threaded type<br>Shielded type<br>Threaded type<br>Non-shielded type<br>**----- End of picture text -----**<br>
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
867
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS
AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS
FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
FIBER SENSORS
## **ORDER GUIDE**
LASER SENSORS **Flexible cable type**
Flexible cable type is also available for shielded type. When ordering this type, suffix “ **-R** ” to the model No. (e.g.) Flexible cable type of **GX-3S** is “ **GX-3S-R** ”.
## **5 m 16.404 ft cable length type**
5 m 16.404 ft cable length type (standard: 3 m 9.843 ft) is also available. (excluding **GX-4SB** ) When ordering this type, suffix “ **-C5** ” to the model No.
(e.g.) 5 m 16.404 ft cable length type of **GX-3S** is “ **GX-3S-C5** ”.
Refer to table below for 5 m 16.404 ft cable length type of flexible cable type sensor.
- **Table of model Nos.**
**==> picture [330 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
Flexible cable of<br>Type Standard 5 m 16.404 ft cable length type<br>GX-3S GX-3S-R-C5<br>GX-3SB GX-3SB-R-C5<br>GX-4S GX-4S-R-C5<br>GX-4SB –<br>Shielded GX-5S GX-5S-R-C5<br>type GX-5SB –<br>GX-5M GX-5M-R-C5<br>GX-5MB –<br>GX-8M GX-8M-R-C5<br>GX-8MB GX-8MB-R-C5<br>Non-threaded type<br>Threaded type<br>**----- End of picture text -----**<br>
## **Accessories**
**• MS-SS3** (Sensor mounting bracket for **GX-3S** type) **• MS-SS3-2** (C bracket for **GX-3S** type) **• MS-SS5** (Sensor mounting bracket for **GX-5S** type)
**==> picture [207 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
• MS-SS3 • MS-SS3-2<br>• MS-SS5<br>By using the C bracket, the applicable<br>tightening force can be doubled.<br>**----- End of picture text -----**<br>
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
868
FIBER SENSORS
LASER SENSORS
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
SENSOR OPTIONS
SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N**
**GX**
## **SPECIFICATIONS**
## **Non-threaded type**
**==> picture [505 x 562] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shielded type<br>Type<br>Flexible cable Flexible cable Flexible cable<br>Item Model No. GX-3S GX-3SB GX-3S-R GX-3SB-R GX-4S GX-4SB GX-4S-R GX-4SB-R GX-5S GX-5SB GX-5S-R GX-5SB-R<br>Max. operation distance (Note 2) 0.8 mm 0.031 in ±15 % 1 mm 0.039 in ±15 %<br>Stable sensing range (Note 2) 0 to 0.6 mm 0 to 0.024 in 0 to 0.8 mm 0 to 0.031 in<br>Standard sensing object Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in Iron sheet 6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in<br>Hysteresis 15 % or less of operation distance (with standard sensing object)<br>Repeatability 20 μm 0.787 mil or less 8 μm 0.315 mil or less<br>Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less 10 to 30 V DC Ripple P-P 10 % or less<br>Current consumption 15 mA or less<br>NPN open-collector transistor<br>NPN open-collector transistor • Maximum sink current: 200 mA (Note 3)<br>• Maximum sink current: 50 mA • Applied voltage: 30 V DC or less<br>Output • Applied voltage: 30 V DC or less (between output and 0 V) (between output and 0 V)<br>• Residual voltage: 0.4 V or less (at 50 mA sink current) • Residual voltage: 1.5 V or less<br>(at 200 mA sink current)<br>0.4 V or less<br>(at 50 mA sink current)<br>Utilization category DC-12 or DC-13<br>Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally<br>Output operation open closed open closed open closed open closed open closed open closed<br>Short-circuit protection – Incorporated<br>Max. response frequency 1 kHz 1.5 kHz<br>Operation indicator Red LED (lights up when the output is ON)<br>Pollution degree 3 (Industrial environment)<br>Protection IP67 (IEC)<br>Ambient temperature –25 to + 70 °C –13 to +158 °F, Storage: –25 to +80 °C –13 to +176 °F<br>Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH 35 to 85 % RH, Storage: 35 to 95 % RH<br>EMC EN 60947-5-2<br>Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure<br>Insulation resistance 5 MΩ, or more, with 250 V DC megger between all supply terminals connected 50 MΩ, or more, with 500 V DC megger between all<br>together and enclosure supply terminals connected together and enclosure<br>Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each<br>Shock resistance 200 m/s [2] acceleration (20 G approx.) in X, Y and Z directions for ten times each 300 m/sX, Y and Z directions for ten times each [2] acceleration (30 G approx.) in<br>Temperature Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ±20 % of Over ambient temperature range –25 to+70 °C –13 to<br>Sensing characteristics sensing range at +20 °C +68 °F +158 °F: Within ±15 % of sensing range at +20 °C +68 °F<br>range<br>variation Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage Within ±2.5 % for ±15 % fluctuation of the supply voltage<br>Material Enclosure: Stainless steel (SUS304), Resin part: TPX Enclosure: Brass (Nickel plated)Resin part: ABS<br>0.08 mm [2] 3-core oil, heat 0.1 mm [2] 3-core flexible, oil 0.08 mm [2] 3-core oil, heat 0.1 mm [2] 3-core flexible, oil 0.14 mm [2] 3-core oil, heat 0.15 mm [2] 3-core flexible, oil<br>Cable and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre<br>cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long<br>Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm [2] , or more, cable.<br>Weight Net weight: 30 g approx. Net weight: 55 g approx.<br>Accessories MS-SS3 MS-SS3-2 (Sensor mounting bracket): 1 pc.(C bracket): 1 pc. – MS-SS5 (Sensor mounting bracket): 1 pc.<br>Environmental resistance<br>**----- End of picture text -----**<br>
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
- 3) The maximum sink current varies depending on the ambient temperature. Refer to “ **I/O CIRCUIT AND WIRING DIAGRAMS** (p.870)” for details.
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
869
FIBER SENSORS
LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS
PARTICULAR USE SENSORS
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS
MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **SPECIFICATIONS**
## **Threaded type**
**==> picture [503 x 593] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shielded type<br>Type Non-shielded type<br>Flexible cable Flexible cable<br>Item Model No. GX-5M GX-5MB GX-5M-R GX-5MB-R GX-8M GX-8MB GX-8M-R GX-8MB-R GX-8ML GX-8MLB<br>Max. operation distance (Note 2) 0.8 mm 0.031 in ±15 % 1 mm 0.039 in ±15 % 2 mm 0.079 in ±15 %<br>Stable sensing range (Note 2) 0 to 0.6 mm 0 to 0.024 in 0 to 0.8 mm 0 to 0.031 in 0 to 1.6 mm 0 to 0.063 in<br>Standard sensing object Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in<br>15 % or less of operation distance<br>Hysteresis 10 % or less of operation distance (with standard sensing object)<br>(with standard sensing object)<br>Repeatability 20 µm 0.787 mil or less 8 µm 0.315 mil or less 40 µm 1.575 mil or less<br>Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less 10 to 30 V DC Ripple P-P 10 % or less<br>Current consumption 15 mA or less<br>NPN open-collector transistor<br>• Maximum sink current: 50 mA NPN open-collector transistor<br>• Maximum sink current: 200 mA (Note 3)<br>• Applied voltage: 30 V DC or less<br>Output • Applied voltage: 30 V DC or less (between output and 0 V)<br>(between output and 0V)<br>• Residual voltage: 1.5 V or less (at 200 mA sink current)<br>• Residual voltage: 0.4 V or less<br>0.4 V or less (at 50 mA sink current)<br>(at 50 mA sink current)<br>Utilization category DC-12 or DC-13<br>Normally Normally Normally Normally Normally Normally Normally Normally<br>Output operation open closed open closed open closed open closed Normally open Normally closed<br>Short-circuit protection – Incorporated<br>Max. response frequency 1 kHz 500 Hz<br>Operation indicator Red LED (lights up when the output is ON)<br>Pollution degree 3 (Industrial environment)<br>Protection IP67 (IEC)<br>Ambient temperature – 25 to +70 °C –13 to +158 °F, Storage: – 25 to +80 °C – 13 to +176 °F<br>Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH 35 to 85 % RH, Storage: 35 to 95 % RH<br>EMC EN 60947-5-2<br>Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure<br>5 MΩ, or more, with 250 V DC megger between all 50 MΩ, or more, with 500 V DC megger between all supply terminals connected<br>Insulation resistance<br>supply terminals connected together and enclosure together and enclosure<br>Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each<br>Shock resistance 200 m/s [2] acceleration (20 G approx.) in 300 m/s [2] acceleration (30 G approx.) in 300 m/s [2] acceleration (30 G approx.) in<br>X, Y and Z directions for ten times each X, Y and Z directions for ten times each X, Y and Z directions for three times each<br>Temperature Over ambient temperature range – 25 to +70 °C –13 to Over ambient temperature range –25 to +70 °C –13 to +158 °F:<br>Sensing characteristics +158 °F: Within ±20 % of sensing range at +20 °C +68 °F Within [+15] –10 [% of sensing range at +20 °C ][+68 °F]<br>range<br>variation Voltage Within ±2 % for ±10 % fluctuation of the<br>characteristics supply voltage Within ±2.5 % for ±15 % fluctuation of the supply voltage<br>Material Enclosure: Brass (Nickel plated) Enclosure: Brass (Nickel plated)<br>Resin part: TPX Resin part: ABS<br>0.08 mm [2] 3-core oil, heat 0.1 mm [2] 3-core flexible, oil 0.14 mm [2] 3-core oil, heat 0.15 mm [2] 3-core flexible, oil 0.14 mm [2] 3-core, oil, heat and cold<br>Cable and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre<br>cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long resistant cabtyre cable, 3 m 9.843 ft long<br>Extension up to total 100 m 328.084 ft is<br>Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm [2] , or more, cable. possible with 0.14 mm [2] , or more, cable.<br>Weight (Note 4) Net weight: 30 g approx. Net weight: 60 g approx.<br>Accessories Nut: 2 pcs. Nut: 2 pcs. Nut: 2 pcs. Nut: 2 pcs. Nut: 2 pcs.<br>Toothed lock washer: 1 pc. Toothed lock washer: 2 pcs. Toothed lock washer: 1 pc. Toothed lock washer: 2 pcs. Toothed lock washer: 1 pc.<br>Environmental resistance<br>**----- End of picture text -----**<br>
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
- 3) The maximum sink current varies depending on the ambient temperature. Refer to “ **I/O CIRCUIT AND WIRING DIAGRAMS** (p.870)” for details.
- 4) The given weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
870
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated **GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **I/O CIRCUIT AND WIRING DIAGRAMS**
## **GX-5S□ GX-8M□ GX-8ML□**
**I/O circuit diagram**
**==> picture [228 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
Color code<br>D (Brown) +V<br>Load<br>Tr (Black) Output + 10 to 30 V DC<br>200 mA max. (Note) –<br>ZD<br>(Blue) 0 V<br>Internal circuit Users’ circuit<br>Sensor circuit<br>**----- End of picture text -----**<br>
Symbols … D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor
- If a capacitor of 1 µF or more is connected between 0 V and output or between +V and output, connect a 100 Ω resistor in series as shown below.
**==> picture [243 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
(Brown) +V +V Without the resistor, the short-<br>circuit protection is activated by<br>1 μF or more<br>(Black) Output the charge or discharge current<br>100Ω Signal of the capacitor, so that it<br>(Blue) 0 V 1 μF or more results in delaying the response<br>0 V whenever the sensor switches.<br>Internal circuit Users’ circuit The connected resistor solves<br>this problem.<br>**----- End of picture text -----**<br>
## **Wiring diagram**
**==> picture [241 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Brown<br>Load<br>Black +<br>10 to 30 V DC<br>–<br>Blue<br>**----- End of picture text -----**<br>
Note: The maximum sink current varies depending on the ambient temperature.
**==> picture [175 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
200<br>100<br>0<br> –25 +55 +70<br>–13 +131 +158<br>Ambient temperature (°C °F)<br>Max. sink current (mA)<br>**----- End of picture text -----**<br>
PLC
## **GX-3S□ GX-4S□ GX-5M□**
**I/O circuit diagram**
**==> picture [228 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Color code<br>D (Brown) +V<br>ZD<br>Load<br>(Black) Output (Note) + 12 to 24 V DC<br>Tr 50mA max. – ±10 %<br>(Blue) 0 V<br>Internal circuit Users’ circuit<br>Sensor circuit<br>**----- End of picture text -----**<br>
## **Wiring diagram**
**==> picture [246 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Brown<br>Load<br>Black + 12 to 24 V DC<br>±10 %<br>–<br>Blue<br>**----- End of picture text -----**<br>
Note: **GX-3S** □, **GX-4S** □ and **GX-5M** □ do not incorporate a short-circuit protection circuit at the output. Do not connect them directly to a power supply or a capacitive load.
Symbols … D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
871
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS
MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H**
**GXL GL**
**GX-M GX-U/GX-FU/ GX-N**
## **SENSING CHARACTERISTICS (TYPICAL)**
## **GX-3S□ GX-4S□ GX-5M□**
**GX**
**==> picture [435 x 666] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sensing field Correlation between sensing object size and sensing range<br>As the sensing object size becomes smaller than<br>0.0792 0.0792 Iron sheet the standard size (iron sheet 5 × 5 × t 1 mm0.197 × 0.197 × t 0.039 in), the sensing range<br>Standard sensing objectIron sheet 5 × 5 × t 1 mm L a × a mmt 1 mmt 0.039 in a × a in shortens as shown in the left figure.<br>0.197 × 0.197 × t 0.039 in<br>1<br>1 0.039<br>0.039<br>ℓ<br>L<br>0<br>4 2 0 2 4 0 5 10 15 20<br>0.157 0.079 0.079 0.157 0.197 0.394 0.591 0.787<br>LeftOperating point ℓ (mm Center Rightin) Sensing object sidelength a (mm in)<br>GX-5S□<br>Sensing field Correlation between sensing object size and sensing range<br>As the sensing object size becomes smaller than<br>0.0792 Standard sensing objectIron sheet6 × 6 × t 1 mm 0.0792 Iron sheet the standard size (iron sheet 6 × 6 × t 1 mm0.236 × 0.236 × t 0.039 in), the sensing range<br>0.236 × 0.236 × t 0.039 in a × a mm a × a in shortens as shown in the left figure.<br>ℓ t 1 mm<br>L t 0.039 in<br>1 1<br>0.039 0.039<br>0<br>4 2 0 2 4 0 5 10 15 20<br>0.157 0.079 0.079 0.157 0.197 0.394 0.591 0.787<br>Left Center Right Sensing object side<br>Operating point ℓ (mm in) length a (mm in)<br>GX-8M□<br>Sensing field Correlation between sensing object size and sensing range<br>As the sensing object size becomes smaller than<br>Standard sensing objectIron sheet the standard size (iron sheet 8 × 8 × t 1 mm<br>0.0792 8 × 8 × t 1 mm0.315 × 0.315 × t 0.039 in 0.0792 Iron sheet 0.315 × 0.315 × t 0.039 in), the sensing range<br>ℓ a × a mm a × a in shortens as shown in the left figure.<br>L L t 1 mmt 0.039 in<br>1 1<br>0.039 0.039<br>0<br>4 2 0 2 4 0 5 10 15 20<br>0.157 0.079 0.079 0.157 0.197 0.394 0.591 0.787<br>Left Center Right Sensing object side<br>Operating point ℓ (mm in) length a (mm in)<br>GX-8ML□<br>Sensing field Correlation between sensing object size and sensing range<br>As the sensing object size becomes smaller than<br>Standard sensing object Iron sheet<br>12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in the standard size (iron sheet 12 × 12 × t 1 mm<br>0.0792 ℓ 0.0792 0.472 × 0.472 × t 0.039 in), the sensing range<br>L shortens as shown in the left figure.<br>1 1<br>0.039 0.039 Iron sheet<br>a × a mm a × a in<br>t 1 mm<br>L t 0.039 in<br>0<br>4 2 0 2 4 0 10 20 30 40<br>0.157 0.079 0.079 0.157 0.394 0.787 1.181 1.575<br>Left Center Right Sensing object side<br>Operating point ℓ (mm in) length a (mm in)<br>)in )in<br>Setting distance L (mm Sensing range L (mm<br>)in )in<br>Setting distance L (mm Sensing range L (mm<br>)in )in<br>Setting distance L (mm Sensing range L (mm<br>)in )in<br>Setting distance L (mm Sensing range L (mm<br>**----- End of picture text -----**<br>
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
872
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **PRECAUTIONS FOR PROPER USE**
- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
## **Mounting**
- The tightening torque should be as given below.
## **Mounting with set screw**
## **<Shielded of threaded type>**
- Tighten the set screw on the flat surface of the sensor without applying excessive force. Make sure to use a set screw with a cup-point end.
Set screw (M4 or less) (Note) A
**==> picture [45 x 33] intentionally omitted <==**
Note: To fasten **GX-5M** □, use a M3 or less set screw.
**==> picture [172 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model No. Set screw tightening Tightening<br>position A (mm in) torque<br>GX-5M □ 5 to 10 0.197 to 0.394 0.29 N·m<br>GX-8M □ 8 to 22 0.315 to 0.866 0.29 N·m<br>**----- End of picture text -----**<br>
## **<Non-threaded type and non-shielded of threaded type>**
**==> picture [237 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
Set screw<br>B (M4 or less) Model No. B (mm in) C (mm in) Tightening<br>torque<br>GX-3S □ 5 to 10 3 0.29 N·m<br>C When using 0.197 to 0.394 0.118 0.58 N·m<br>the C bracket<br>5 to 10 3<br>GX-4S □ 0.58 N·m<br>0.197 to 0.394 0.118<br>8 to 20 5<br>GX-5S □ 0.29 N·m<br>0.315 to 0.787 0.197<br>13 to 22 10<br>GX-8ML □ 0.29 N·m<br>0.517 to 0.866 0.394<br>**----- End of picture text -----**<br>
## Refer to p.1485~ for general precautions.
## **Mounting with nut**
- Note that the maximum tightening torque differs according to the location of the nuts.
**==> picture [239 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
<Shielded of threaded type> <Non-shielded of threaded type><br>D D<br>Attached toothed<br>Mounting plate lock washer<br>Mounting plate<br>Attached toothed lock washer<br>(2 pcs. attached for “ -R ” type only)<br>Model No. D (mm in) Tightening torque<br>2 to 3 0.079 to 0.118 0.49 N·m<br>GX-5M □<br>3 0.118 or more 1.47 N·m<br>3 to 11 0.118 to 0.433 1.47 N·m<br>GX-8M □<br>11 0.433 or more 3.43 N·m<br>9 to 11 0.345 to 0.433 0.98 N·m<br>GX-8ML □<br>11 0.433 or more 3.43 N·m<br>**----- End of picture text -----**<br>
Note: Mount such that the nuts do not protrude from the threaded portion.
- The root truncation of the threads with **GX-8M** □ and **GX-8ML** □ is shallow owing to strengthening of the sensors against tightening. When tapping holes on equipment to fix the sensors, the prepared holes must be ø7.2 mm ø0.283 in or more ~~.~~
**==> picture [127 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tapping holes<br>Sensor<br>Tap<br>**----- End of picture text -----**<br>
Note: The protrusion should be kept C (mm in) or more to avoid reduction of sensing range.
- To fasten **GX-3S** □ and **GX-4S** □, use a M3 or less set screw and tighten it from a direction perpendicular to the operation indicator.
**==> picture [208 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation<br>indicator Operation Operation<br>indicator indicator<br>Set screw<br>**----- End of picture text -----**<br>
- When using the C bracket, place it on the sensor at a distance of 3 mm 0.118 in or more from the sensor end.
C bracket
- 3 mm 0.118 in or more
- To fasten the non-shielded threaded type, tighten the set screw on the flat surface of the sensor.
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
873
Refer to p.1485~ for general precautions.
FIBER SENSORS
LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
WIRE-SAVING SYSTEMS
MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS
MACHINE VISION SYSTEMS
UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **PRECAUTIONS FOR PROPER USE**
## **Distance from surrounding metal**
- As metal around the sensor may affect the sensing performance, pay attention to the following points.
## **Influence of surrounding metal**
- The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the table below.
**==> picture [230 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model No. E (mm in)<br>GX-3S □ 3 0.118<br>E GX-4S □ 3 0.118<br>GX-5S □ 4 0.157<br>GX-5M □ 3 0.118<br>GX-8M □ 4 0.157<br>GX-8ML □ 8 0.315<br>Background metal<br>**----- End of picture text -----**<br>
## **Embedding of the sensor in metal**
- Sensing range may decrease if the sensor is completely embedded in metal. Especially for the non-threaded type and the non-shielded type, keep the minimum distance specified in the table below.
**==> picture [230 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model No. F (mm in) G (mm in)<br>GX-3S □ ø12 ø0.472 3 0.118<br>F<br>G GX-4S □ ø12 ø0.472 3 0.118<br>Metal GX-5S □ ø15.4 ø0.606 5 0.197<br>GX-8ML □ ø30 ø1.181 10 0.394<br>**----- End of picture text -----**<br>
## **Sensing range**
- The sensing range is specified for the standard sensing object. With a non-ferrous metal, the sensing range is obtained by multiplying with the correction coefficient specified below. Further, the sensing range also changes if the sensing object is smaller than the standard sensing object or if the sensing object is plated.
## **Correction coefficient**
**==> picture [240 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model No.<br>GX-5S □<br>GX-3S □<br>GX-5M □ GX-8M □<br>GX-4S □<br>GX-8ML □<br>Metal<br>Iron 1 1 1<br>Stainless steel<br>0.65 approx. 0.83 approx. 0.7 approx.<br>(SUS304)<br>Brass 0.36 approx. 0.61 approx. 0.4 approx.<br>Aluminum 0.30 approx. 0.58 approx. 0.35 approx.<br>**----- End of picture text -----**<br>
## **Others**
- Do not use during the initial transient time (10 ms) after the power supply is switched on.
- Make sure that stress by forcible bend or pulling is not applied directly to the sensor cable joint.
- **GX-3S** □, **GX-4S** □ and **GX-5M** □ do not incorporate a short-circuit protection circuit at the output. Do not connect them directly to a power supply or a capacitive load.
## **Mutual interference**
- When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference.
**==> picture [239 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
Face to face mounting<br>Model No. H (mm in) J (mm in)<br>H<br>GX-3S □ 16 0.630 16 0.630<br>GX-4S □ 16 0.630 16 0.630<br>Parallel mounting<br>GX-5S □ 20 0.787 15 0.591<br>GX-5M □ 10 0.394 10 0.394<br>J<br>GX-8M □ 20 0.787 15 0.591<br>GX-8ML □ 50 1.969 30 1.181<br>**----- End of picture text -----**<br>
Cylindrical Compact Inductive Proximity Sensor **GX SERIES**
874
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS
PLC
HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Amplifier Built-in Amplifierseparated
**GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX**
## **DIMENSIONS (Unit: mm in)**
**==> picture [235 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
The CAD data in the dimensions can be downloaded from our website.<br>**----- End of picture text -----**<br>
**==> picture [502 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
GX-3S□ Sensor GX-4S□ Sensor<br>4 Operation indicator (Red) 4 Operation indicator (Red)<br>19 0.157 19 0.157<br>0.748 0.748<br>ø3.8 ø4.4<br>ø0.150 30 ø0.173 30<br>1.181 ø2.6 ø0.102 cable, 1.181 ø2.6 ø0.102 cable,<br>3 m 9.843 ft long 3 m 9.843 ft long<br>GX-5S□ Sensor GX-5M□ Sensor<br>3 Operation indicator (Red) Toothed lock<br>17.1 0.118 washer<br>0.673 (Internally toothed)<br>4.4 Operation indicator (Red)<br>0.173 18<br>ø10 0.709 ø2.6 ø0.102 cable,<br>ø0.394 3 m 9.843 ft long<br>ø5.4<br>ø0.213 1.18130 ø3.5 ø0.138 cable,<br>3 m 9.843 ft long<br>0.3158 0.0792 19 0.1574 ø0.150ø3.8<br>0.748<br>30<br>Flat part 1.181<br>M5 × 0.5 0.020 thread<br>GX-8M□ Sensor GX-8ML□ Sensor<br>30 3 30 3<br>1.181 0.118 1.181 0.118<br>Toothed lock washer<br>Toothed lock washer<br>0.47212 0.1183 (Internally toothed)Operation indicator (Red)ø3.5 3 m 9.843 ftø0.138 long cable, 0.47212 ø0.252ø6.4 0.1183 0.94524 Operation indicator (Red)(Internally toothed)<br>6 ø5<br>ø15 ø15 0.236 ø0.197<br>7.4 ø0.591 0.2366 ø5ø0.197 0.2917.4 ø0.591 Flat part M8 × 10.039 thread ø3.5 3 m 9.843 ftø0.138 long cable,<br>0.291<br>Flat part M8 × 1 0.039 thread<br>**----- End of picture text -----**<br>
**==> picture [69 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
MS-SS3-2<br>**----- End of picture text -----**<br>
## C bracket for **GX-3S□** (Accessory for **GX-3S□** )
**==> picture [93 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
t 0.45<br>t 0.018<br>(4.75)<br>(0.187)<br>14<br>0.551<br>**----- End of picture text -----**<br>
Note: By using the C bracket, the applicable tightening force can be doubled.
## **MS-SS3 MS-SS5**
Sensor mounting bracket for **GX-3S□** (Accessory for **GX-3S□** ) Sensor mounting bracket for **GX-5S□** (Accessory for **GX-5S□** )
**==> picture [240 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-ø3.5 ø0.138<br>mounting holes Model No.<br>MS-SS3 MS-SS5<br>C Symbol<br>A 16 0.630 18 0.709<br>B 9 0.354 10 0.394<br>A B<br>C 6.3 0.248 8.3 0.327<br>4 0.157<br>D 4.9 0.193 6.1 0.240<br>4 8 4<br>0.157 0.315 0.157 Applicable GX-3S □ GX-5S □<br>16 D model No.<br>0.630<br>Material: Nylon 66<br>**----- End of picture text -----**<br>
Updated at February 9, 2023
Panasonic Industry is a global leader in the design and manufacture of high-quality electronic components. Renowned for a commitment to continuous innovation, the company provides the essential building blocks that empower modern engineering. From industrial automation to consumer electronics, Panasonic's components are trusted worldwide for their outstanding reliability, efficiency, and long-term performance. The extensive portfolio is anchored by a massive selection of passive components, featuring an industry-leading range of aluminium electrolytic, film, and polymer capacitors. Alongside these advanced capacitance solutions, engineers rely on Panasonic's robust power inductors and a highly versatile array of electromechanical devices, including solid-state, power, and signal relays engineered to excel in demanding environments. Beyond core passives and switching solutions, the offering encompasses critical circuit protection devices such as TVS varistors and NTC thermistors, as well as sophisticated thermal management materials. Panasonic also delivers precision light and motion sensors, highly reliable batteries, and advanced Bluetooth and WLAN connectivity modules, providing a comprehensive ecosystem of components to support next-generation technological design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →