GUS600-36/R
AC/DC Enclosed Power Supply (PSU), ITE, Laboratory Equipment, Industrial, LED Lighting, 1 Outputs
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: GUS Series
- No. of Outputs: 1Outputs
- Output Power Max: 601.2W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 16.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 36V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Laboratory Equipment, Industrial, LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 156.54 € |
| Current stock | 10+ |
| Lead time | 30 days |
GUS350-1000 Series https://product.tdk.com/en/power/gus www.emea.lambda.tdk.com/gus 350W to 1000W Compact Single Output General Purpose Power Supplies The compact 350W, 600W and 1000W rated GUS power supplies are designed to provide reliable performance at an economical price. The GUS models are available with 12, 24, 36 and 48V output voltages and have efficiencies up to 95%. All models are certified to IEC62368-1, designed to meet IEC61010-1 and meet Class B radiated and conducted EMI standards. Remote on/off is an option for all models, with the GUS350 having an optional output voltage adjustment function (standard on GUS600 and GUS1000). The GUS600 and GUS1000 models have an internal cooling fan with the GUS350 being convection cooled. |**Features**|**Benefits**| |---|---| |• Compact Size|• Saves Space in System| |• Conservative Electrolytic Capacitor Ratings|• Long Field Life| |• Class B Conducted and Radiated EMI|• Easier System EMC Compliance| |• IEC62368-1 Certification, Compliant to IEC61010-1|• Quicker System Compliance| ## **Model Selector** |Model|Model|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Output Adjustment (V)<br>Voltage<br>(Specify ADJ option suffix for GUS350,<br>(V)<br>standard on the GUS600 and GUS1000)|Max<br>Current<br>(A)|Max<br>Current<br>(A)|Max<br>Current<br>(A)|Current|Max Output<br>Power<br>(W)|Ripple<br>& Noise<br>(mV)|Ovevoltage<br>(V)|Overcurrent (115 / 230Vac)<br>(A)|Efficiency (typ)<br>Overcurrent (115 / 230Vac)<br>(%)|Efficiency (typ)<br>Overcurrent (115 / 230Vac)<br>(%)| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |GUS350-12|||12|||11.7 - 12.9||||29.2|||350.4|240|13.80 - 16.20|>30.66|93 / 95|| |GUS600-12|||12|||11.7 - 12.9||||50|||600|240|13.80 - 16.20|>52.50|92 / 94|| |GUS1000-12||GUS1000-12|12|||11.7 - 12.6||66.7 (83.4 peak) 800.4 (1000.8 peak)||66.7 (83.4 peak) 800.4 (1000.8 peak)||||240|13.80 - 16.20|>87.6|91 / 93|| |GUS350-24|||24|||23.4 - 25.9||||14.6|||350.4|360|27.60 - 32.40|>15.33|94 / 95.5|| |GUS600-24|||24|||23.4 - 25.9||||25|||600|360|27.60 - 32.40|>26.25|93 / 95|| |GUS1000-24||GUS1000-24|24|||23.4 - 25.9||||41.7|||1000.8|360|27.60 - 32.40|<43.8|93 / 95|| |GUS350-36|||36|||35.1 - 38.8||||9.8|||352.8|480|41.40 - 48.60|>10.29|94 / 95.5|| |GUS600-36|||36|||35.1 - 38.8||||16.7|||601.2|480|41.40 - 48.60|>17.54|93 / 95|| |GUS1000-36||GUS1000-36|36|||35.1 - 38.8||||27.8|||1000.8|480|41.40 - 48.60|>29.2|93.3 / 95.3|| |GUS350-48|||48|||46.8 - 51.8||||7.4|||355.2|480|55.20 - 64.80|>7.77|94 / 95.5|| |GUS600-48|||48|||46.8 - 51.8||||12.6|||604.8|480|55.20 - 64.80|>13.23|93 / 95|| |GUS1000-48||GUS1000-48|48|||46.8 - 51.8||||20.9|||1003.2|480|55.20 - 64.80|22|93.5 / 95.5|| |||||||||||||||||||| |**GUS350**||**GUS350**||||**24**|||**/**|**/**|||||**R**|||| |||||||||||||||||||| ||Model and Output power|Model and Output power||||Output voltage 12, 24, 36, 48||||||Blank No options<br>R|Blank No options<br>Remote On/Off|||||| |||||||||||||ADJ|Output voltage adjustment potentiometer|||||| ||||||||||||||(option for GUS350 only, standard on the GUS600 and GUS1000)|||(option for GUS350 only, standard on the GUS600 and GUS1000)|(option for GUS350 only, standard on the GUS600 and GUS1000)|| |||||||||||||/D|DIN rail mounting bracket (GUS350-24 only)||DIN rail mounting bracket (GUS350-24 only)|||| ## **Related Products** |Type|Part Number(s)||Description| |---|---|---|---| |AC-DC power supplies|RWS-B||50 to 1500W, industrial 7-year warranty| |AC-DC power supplies|CUS-M|30 to 1500W, industrial/medical 5-year warranty|30 to 1500W, industrial/medical 5-year warranty| GUS350-1000 Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---|---| |Model<br>GUS350<br>GUS600<br>GUS1000||||| |**Input**||||| |AC Input Voltage Range (Operating)|Vac|85 - 265(1)<br>||| |Nominal Input Voltage Range|Vac|100 - 240 (Note: Safety certifed for 90 - 264Vac only)||| |AC Input Frequency|Hz|47 - 63||| |Input Current (115/230Vac)|A|3.4 / 1.7|6 / 3|12V: 4 / 4, 24-48V: 10 / 5| |Inrush Current at 115/200Vac (Cold Start)|A|25 / 50||| |Leakage Current|mA|< 0.75||< 0.5| |Power Factor (10/200Vac)|-|0.99 / 0.95||| |Harmonic Compliance|-|Meets IEC61000-3-2. Class A||| |Hold Up Time (typical)<br>|ms|12||11| |Effciency|-|See model selector table||| |Conducted & Radiated EMI|-|EN55011/EN55032-B||| |Immunity<br>|-|IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11||| |Safety Certifcations and Markings|-|IEC/EN/UL/CSA 62368-1. CE Mark and UKCA Mark.<br>Designed to meet IEC 61010-1 and IEC62477-1 (OVC III)||| |**Output**||||| |Switching Frequency|kHz|40 to 260|50 to 300|40 to 300| |Line Regulation|-|12V: 48, 24V: 96, 36V: 144, 48: 192||12V: 60, 24V: 120, 36V: 180, 48: 240| |Load Regulation|-|12V: 96, 24V: 192, 36V: 288, 48: 384||12V: 120, 24V: 240, 36V: 360, 48: 480| |External Load Capacitance (Maximum)|uF|12V: 10,000, 24V: 7,200,<br>36V: 1,400, 48V: 1,300|12V & 24V: 10,000,<br>36V: 7,500, 48V:1,500|12-36V: 10,000,<br>48V: 5,000| |Ripple & Noise<br>|-|See model selector table||| |Temperature Coeffcient|%/°C|0.02||| |Minimum Load|-|No minimum load required||| |Overcurrent Protection|%|See model selector table||| |Overvoltage Protection|-|Latching (unit shutdown), cycle AC input to reset||| |Overtemperature Protection|-|Latching (unit shutdown), cycle AC input to reset||| |Remote Sense|-|No||| |Remote On/Off|-|Specify option R||| |Indicators|-|Green LED indicates DC is OK||| |**Environmental**||||| |Operating Temperature|°C|-20 to +70 (See derating curves below) (-40 start-up)||| |Storage Temperature|°C|-40 to +85||| |Humidity (non condensing)|%RH|Operating and Storage: 10 - 95||| |Cooling|-|Convection|Internal fan|| |Altitude|m|<5000 (<4,000 for IEC62477-1)||| |Withstand Voltage (For 1 minute)|Vac|Input to ground 2,000, Input to output 3,000, Output to ground 500 for 1 minute||| |Vibration (Non operating)|-|10-55Hz (Sweep for 1min.) 19.6m/s2 Constant X,Y,Z 1 hour each||| |Shock (Non operating)|-|Less than 196m/s2, 11ms, ±X, ±Y, ±Z 3 times each||| |**Other**||||| |Weight (Typ)|g|550|800|910| |Size (WxHxD)|mm|101.6 x 41 x 127|101.6 x 41 x 152.4|101.6 x 41 x 177.8| |Size (WxHxD)|Inches|4 x 1.61 x 5|4 x 1.61 x 6|4 x 1.61 x 7| |Connectors|-|Screw terminal input and output. Signal connectors JST S2B-EH. See output drawings||| |MTBF - Telcordia SR-332 issue 3*|Hours|1,573,939 (at 25°C, 12V, 230Vac)|2,480,315 (at 25°C, 12V, 115Vac)|1,193,215 (at 25°C, 12Vdc, 115Vac)| |Warranty|Years|3 years||| Notes: See website for detailed specifications, test methods and installation manual (1) Derate below 115Vac input. See derating curves (*) ambient, at full load, output voltage, Vac input, full load GUS350-1000 Series 2 ## **GUS350 Immunity** |<br>**GUS350 Immunity**||||| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|Notes:| |ESD|EN61000-4-2|Contact Discharge: 8kV<br>Air Discharge: 15kV|A|-| |Radiated Susceptibility|EN61000-4-3|Radiation Field Strength 3V/m<br>Radiation Field Strength 10V/m|A|Electromagnetic Frequency: 1.4 - 6GHz<br>Electromagnetic Frequency: 80 - 1000GHz| |Electrical Fast Transient Burst|EN61000-4-4|Input Power Port and Enclosure Port: 4kV<br>Output Power Port and Signal Port: 2kV|A|-| |Surge|EN61000-4-5|Common Mode: 4kV<br>Normal Mode: 2kV|A|-| |Conducted Susceptibility|EN61000-4-6|10V|A|-| |Magnetic fields|EN61000-4-8|30A/m<br>Dip: 20% 5000ms|A<br>A|-<br>-| |||Dip: 30% 500ms|A|-| ||IEC61000-4-11|Dip: 60% 200ms|A/B|A: ≤150W, B: >150W| ||100-120Vac input|Dip: 100% 10ms|A|-| |||Dip: 100% 20ms|A/B|A: ≤200W, B: >200W| |Voltage Dips and||Dip: 100% 5000ms|B|-| |Input Interruptions||Dip: 20% 5000ms|A|-| |||Dip: 30% 500ms|A|-| ||IEC61000-4-11|Dip: 60% 200ms|A|-| ||200-240Vac input|Dip: 100% 10ms|A|-| |||Dip: 100% 20ms|A/B|A: ≤200W, B: >200W| |||Dip: 100% 5000ms|B|-| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200Vac| ## **GUS Mounting** GUS350-1000 Series 3 ## **Outline Drawing GUS350** ## **Outline Drawing GUS600** GUS350-1000 Series 4 ## **Outline Drawing GUS1000** GUS350-1000 Series 5 ## **GUS350 Derating Curves vs Input Voltage** ## **GUS600 Derating Curves vs Input Voltage** ## **GUS1000 Derating Curves vs Input Voltage** ## **GUS350-12 Derating Curves vs Temperature** ## **GUS600 Derating Curves vs Temperature** ## **GUS350-24,-36,-48 Derating Curves vs Temperature** ## **GUS1000 Derating Curves vs Temperature** GUS350-1000 Series 6 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ GUS_Datasheet_360212 Sept 3rd, 2025 V4 GUS350-1000 Series 7
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →