- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:40W; Output Voltage - Output 1:7.5V; Output Current - Output 1:5.34A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connector:Barr
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: GST40A Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 11mm
- Output Power Max: 40W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5.34A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 7.5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 15.47 € |
| Current stock | 25+ |
| Lead time | 30 days |
**GST40A series**
40W AC-DC High Reliability Industrial Adaptor
## ■ ****
- ‧
- ‧
- ‧
- ‧ ****
## ■ ****
- ‧
- ‧
- ‧
- ‧
- ‧
-
- ‧Ⅰ
- ‧
- ‧
- ‧
- ‧℃
- ‧
- ‧
## ■ ****
Ⅰ
## ■ ****
** **
ψ ψ {
_File Name:GST40A-SPEC 2016-03-16_
**GST40A series**
40W AC-DC High Reliability Industrial Adaptor
## **SPECIFICATION**
||**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGENote.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.)Note.3**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note. 7)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>GST40A05<br>**GST40A05-P1J GST40A07-P1J GST40A09-P1J GST40A12-P1J GST40A15-P1J GST40A18-P1J GST40A24-P1J GST40A48-P1J**<br>7.5V<br>GST40A07<br>9V<br>GST40A09<br>12V<br>GST40A12<br>15V<br>GST40A15<br>18V<br>GST40A18<br>24V<br>GST40A24<br>48V<br>GST40A48<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p<br>**VOLTAGE TOLERANCENote.4**<br>**LINE REGULATIONNote.5**<br>**LOAD REGULATION**<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>84.5%<br>87.5%<br>7.88 ~ 10.13V<br>88.5%<br>9.45 ~ 12.15V<br>89.5%<br>12.6 ~ 16.2V<br>90%<br>15.75 ~ 20.25V<br>90%<br>18.9 ~ 24.3V<br>91%<br>25.2 ~ 32.4V<br>92%<br>50.4 ~ 64.8V<br>1A / 115VAC 0.5A / 230VAC<br>65A / 230VAC<br>0.75mA / 240VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>736.4K hrs min. MIL-HDBK-217F(25℃)<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20% ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03% /℃(0~50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>125*50*31.5mm (L*W*H)<br>0.28Kg; 40pcs/12.02Kg/1.05CUFT<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 3 ; Other type available by customer requested<br>℃<br><br><br><br><br><br><br>For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>5.25 ~ 6.75V<br>5A<br>5.34A<br>4.45A<br>3.34A<br>2.67A<br>2.22A<br>1.67A<br>0.84A<br>0 ~ 5A<br>0 ~ 5.34A<br>0 ~ 4.45A<br>0 ~ 2.67A<br>0 ~ 2.22A<br>0 ~ 1.67A<br>0 ~ 0.84A<br>25W<br>40W<br>40W<br>40W<br>0 ~ 3.34A<br>40W<br>40W<br>40W<br>40W<br>Protection type : Shut down o/p voltage, re-power on to recover<br>1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load<br>50ms / 230VAC 15ms / 115VAC at full load<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>See page<br>ther type available by customer requested<br>3 ; O<br>UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved<br>Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B,CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGENote.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.)Note.3**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note. 7)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>GST40A05<br>**GST40A05-P1J GST40A07-P1J GST40A09-P1J GST40A12-P1J GST40A15-P1J GST40A18-P1J GST40A24-P1J GST40A48-P1J**<br>7.5V<br>GST40A07<br>9V<br>GST40A09<br>12V<br>GST40A12<br>15V<br>GST40A15<br>18V<br>GST40A18<br>24V<br>GST40A24<br>48V<br>GST40A48<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p<br>**VOLTAGE TOLERANCENote.4**<br>**LINE REGULATIONNote.5**<br>**LOAD REGULATION**<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>84.5%<br>87.5%<br>7.88 ~ 10.13V<br>88.5%<br>9.45 ~ 12.15V<br>89.5%<br>12.6 ~ 16.2V<br>90%<br>15.75 ~ 20.25V<br>90%<br>18.9 ~ 24.3V<br>91%<br>25.2 ~ 32.4V<br>92%<br>50.4 ~ 64.8V<br>1A / 115VAC 0.5A / 230VAC<br>65A / 230VAC<br>0.75mA / 240VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>736.4K hrs min. MIL-HDBK-217F(25℃)<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20% ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03% /℃(0~50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>125*50*31.5mm (L*W*H)<br>0.28Kg; 40pcs/12.02Kg/1.05CUFT<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 3 ; Other type available by customer requested<br>℃<br><br><br><br><br><br><br>For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>5.25 ~ 6.75V<br>5A<br>5.34A<br>4.45A<br>3.34A<br>2.67A<br>2.22A<br>1.67A<br>0.84A<br>0 ~ 5A<br>0 ~ 5.34A<br>0 ~ 4.45A<br>0 ~ 2.67A<br>0 ~ 2.22A<br>0 ~ 1.67A<br>0 ~ 0.84A<br>25W<br>40W<br>40W<br>40W<br>0 ~ 3.34A<br>40W<br>40W<br>40W<br>40W<br>Protection type : Shut down o/p voltage, re-power on to recover<br>1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load<br>50ms / 230VAC 15ms / 115VAC at full load<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>See page<br>ther type available by customer requested<br>3 ; O<br>UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved<br>Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B,CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1|**GST40A05-P1J GST40A07-P1J GST40A09-P1J GST40A12-P1J GST40A15-P1J GST40A18-P1J GST40A24-P1J GST40A48-P1J**|
|---|---|---|---|
|||**SAFETY MODEL NO.**|GST40A05<br>GST40A07<br>GST40A09<br>GST40A12<br>GST40A15<br>GST40A18<br>GST40A24<br>GST40A48|
|||**DC VOLTAGENote.2**|5V<br>7.5V<br>9V<br>12V<br>15V<br>18V<br>24V<br>48V|
|||**RATED CURRENT**|5A<br>5.34A<br>4.45A<br>3.34A<br>2.67A<br>2.22A<br>1.67A<br>0.84A|
|||**CURRENT RANGE**|0 ~ 5A<br>0 ~ 5.34A<br>0 ~ 4.45A<br>0 ~ 2.67A<br>0 ~ 2.22A<br>0 ~ 1.67A<br>0 ~ 0.84A<br>0 ~ 3.34A|
|||**RATED POWER (max.)**|25W<br>40W<br>40W<br>40W<br>40W<br>40W<br>40W<br>40W|
|||**RIPPLE & NOISE (max.)Note.3**|150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p|
|||**VOLTAGE TOLERANCENote.4**|±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%|
|||**LINE REGULATIONNote.5**|±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%|
|||**LOAD REGULATION**|±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.5%<br>±2.5%|
|||**SETUP, RISE TIMENote.6**|1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load|
|||**HOLD UP TIME (Typ.)**|50ms / 230VAC 15ms / 115VAC at full load|
|||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC|
|||**FREQUENCY RANGE**|47 ~ 63Hz|
|||**EFFICIENCY (Typ.)**|84.5%<br>87.5%<br>88.5%<br>89.5%<br>90%<br>90%<br>91%<br>92%|
|||**AC CURRENT (Typ.)**|1A / 115VAC 0.5A / 230VAC|
|||**INRUSH CURRENT (max.)**|65A / 230VAC|
|||**LEAKAGE CURRENT(max.)**|0.75mA / 240VAC|
|||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|
|||**OVER VOLTAGE**|7.88 ~ 10.13V<br>9.45 ~ 12.15V<br>12.6 ~ 16.2V<br>15.75 ~ 20.25V<br>18.9 ~ 24.3V<br>25.2 ~ 32.4V<br>50.4 ~ 64.8V<br>5.25 ~ 6.75V<br>Protection type : Shut down o/p voltage, re-power on to recover|
|||**WORKING TEMP.**|-30 ~ +70℃(Refer to "Derating Curve")|
|||**WORKING HUMIDITY**|20% ~ 90% RH non-condensing|
|||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH|
|||**TEMP. COEFFICIENT**|±0.03% /℃(0~50℃)|
|||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|
|||**SAFETY STANDARDS**|UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved|
|||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|
|||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|
|||**EMC EMISSION**|Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B,CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1|
|||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A|
|||**MTBF**<br>|736.4K hrs min. MIL-HDBK-217F(25℃)|
|||**DIMENSION**|125*50*31.5mm (L*W*H)|
|||**PACKING**|0.28Kg; 40pcs/12.02Kg/1.05CUFT|
|||**PLUG**|See page<br>ther type available by customer requested<br>3 ; O|
|||**CABLE**<br>See page 3 ; Other type available by customer requested<br>℃<br><br><br><br><br><br><br>For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)||
_File Name:GST40A-SPEC 2016-03-16_
**GST40A series**
## 40W AC-DC High Reliability Industrial Adaptor
**==> picture [481 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>Mechanical Specification Case No. GS60A Unit:mm<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br>
**==> picture [42 x 32] intentionally omitted <==**
**==> picture [419 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
UL1185 16AWG 1000±50mm for 5 ~ 15V<br>125 UL1185 18AWG 1800±50mm for 18 ~ 48V<br>POWER LED<br>70±10mm<br>C"+"<br>11±0.5mm<br>ID 2.1 x OD 5.5<br>Outside Inside<br>-V not connected to AC FG<br>**----- End of picture text -----**<br>
## **Plug Assignment**
**==> picture [99 x 75] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard plug: P1J<br>P1J<br>P/N OUTPUT<br>CENTER +<br>**----- End of picture text -----**<br>
## **Installation Manual**
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
_File Name:GST40A-SPEC 2016-03-16_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →