GSP500PS12-EF
AC/DC Enclosed Power Supply (PSU), ITE & Medical, 1 Outputs, 500 W, 12 VDC, 42 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:500W; Output Voltage - Output 1:12V; Output Current - Output 1:42A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Volta
- SVHC: No SVHC (15-Jan-2018)
- Product Range: GSP500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 500W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 42A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 234.56 € |
| Current stock | 10+ |
| Lead time | 30 days |
GSP500 series ## 500W **Fancooled** 180W **Convection cooled** **AC-DC power supplies** The GSP500 has been designed to offer a full 500W of output power in a very small mechanical footprint, whilst still providing peak power to 650W, a 5V standby output with 2 Amps of current capability and an input standby power draw of <1W when the inhibit is activated. Approved for both IT and medical applications the series has output versions from 12V to 48VDC and can be supplied as a U channel for system cooling or with optional very quiet integral fans (-EF). These fans are intelligently controlled to provide the most optimised acoustic noise in the system and further more the GSP500 can provide up to 180W without fan cooling, thus allowing fans to be switched off during periods of lower system loading. ## **Features** ## **Applications** ## **Dimensions** - f 500W fan cooled 180W convection cooled - f 650W peak power - f 152.4 x 101.6mm (6" x 4") footprint, 41.9mm profile - f Regulated single outputs 12V, 24V & 48VDC - f Input range 80 to 264VAC - f Medical & ITE safety approvals **==> picture [143 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> Healthcare Industrial Instrumentation<br>electronics<br>=)<br>Medical Technology<br>diagnostic<br>**----- End of picture text -----**<br> GSP500: 152.4 x 101.6 x 41.9 mm (6.00” x 4.00” x 1.65”) GSP500-EF: 170.4 x 101.6 x 41.9 mm (6.71” x 4.00” x 1.65”) **Documentation** —_ For further information click the link or scan the code - f <0.5W standby power - f Remote On/Off xppower.com - f 5VDC 2A standby - f -40°C to +70°C operation - f 3 year warranty ## **Models & ratings** |Model number(1,3)|Output<br>voltage V1|Output current V1|Output current V1|V standby output|V standby output|Fan supply|Max output power|Max output power| |---|---|---|---|---|---|---|---|---| |||Convection|Fan|Convection|Fan||Nom|Peak(2)| |GSP500PS12-EF|12.0VDC|15.00A|42.0A|5V/1A|5V/2A|12 V/0.3A|500W|650W| |GSP500PS24-EF|24.0VDC|7.50A|21.0A|5V/1A|5V/2A|12 V/0.3A|500W|650W| |GSP500PS48-EF|48.0VDC|3.75A|10.5A|5V/1A|5V/2A|12 V/0.3A|500W|650W| Notes: 1. Remove suffix -EF (EndFan) for use with integral system cooling. 2. Peak power available for 100ms maximum with a 10% duty cycle. The average power in a period should be equal or less than the normal power. 3. For optional current share version, add suffix ‘P’, e.g. GSP500PS24P or GSP500PS24P-EF. 1 L] **AC-DC power supplies** ## GSP500 series ## **Input** **==> picture [553 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Input voltage - operating 80 115/230 264 VAC Derate output power <90VAC. See fig 1<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Input voltage - operating|80|115/230|264|VAC|Derate output power <90VAC. See fg 1| |Input voltage - fault condition|||300|VAC|5 seconds max| |Input frequency|47|50/60|63|Hz|| |Power factor||>0.9|||230VAC, 100% load| |Input current - full load||5.0/2.4||A|115/230 VAC| |Inrush current||60||A|| |Earth leakage current||80/220|250|µA|115/230VAC/50Hz Typ., 264VAC/60Hz Max| |No load input power|||0.5|W|All models, when inhibit activated| |||3.0|||GSP500PS12 - 115VAC| |||1.3|||GSP500PS12 - 230VAC| |||3.0|||GSP500PS24 - 115VAC| |||1.2|||GSP500PS24 - 230VAC| |||4.8|||GSP500PS48 - 115VAC| |||2.3|||GSP500PS48 - 230VAC| |Input protection|F16A/250V internal fuse in both lines||||| Input voltage derating curve Figure 1 **==> picture [288 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> 550<br>500<br>450<br>400<br>350<br>300<br>80 85 90 264 300<br>Input voltage (VAC)<br>Output power (W)<br>5 seconds maximum<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 2 **AC-DC power supplies** ## GSP500 series ## **Output** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage - V1|12||48|VDC|See models and ratings table| |Initial set accuracy|||±1|%|50% load, 115/230VAC| |Output voltage adjustment - V1|||+1, -3|%|| |Minimum load|No minimum load required||||| |Start up delay||0.5|2|s|115/230VAC, full load from input AC turn on| |Hold up time|20|||ms|| |Drift|||±0.02|A|After 20 min warm up| |Line regulation||0.01|0.5|%|90-264VAC| |Load regulation||0.2|1.0|%|0-100% load| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Over/undershoot|||0|%|| |Ripple & noise||0.5|1.5|% pk-pk|20MHz bandwidth| |Overvoltage protection|115||140|%|Vnom DC. Output 1, recycle input to reset| |Overload protection|110||150|% I nom|See fg. 2. Trip and restart| |Short circuit protection|Shutdown and autorecovery||||| |Temperature coeffcient|||0.05|%/˚C|| |Overtemperature protection|Shutdown and autorecovery||||| Output overload characteristic Figure 2 GSP500PS12 example (other similar) **==> picture [265 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> 12<br>Trip & Restart<br>10<br>8<br>6<br>4<br>2<br>0<br>0 42 44 46 48 50 52 54 56 58 60<br>Output Load (A)<br>Output voltage (V)<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 3 **AC-DC power supplies** ## GSP500 series ## **General** **==> picture [554 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 90 % 230VAC, full load (see fig. 3-5)<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency||90||%|230VAC, full load (see fg. 3-5)| |Isolation: input to output<br>input to ground<br>output to ground|4000|||VAC|2 x MOPP| ||1500|||VAC|1 x MOPP| ||500|||VDC|| |Switching frequency||65||kHz|PFC converter| ||50|90|200||Main converter| |||100|||Standby converter| |Power density|||0.768 (12.6)|W/cm3(W/in3)|Fan cooled| |Mean time between failure||216||khrs|MIL-HDBK-217F, Notice 2 +25°C GB| |Weight||0.85 (1.87)||kg (lb)|GSP500PSxx models| |||0.90 (1.98)|||GSP500PSxx-EF models| ||||||| ## **Efficiency graphs** ## Efficiency vs load **==> picture [547 x 254] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 3 Figure 4<br>GSP500PS12 GSP500PS24<br>100 100<br>80 80<br>60 115VAC 60 115VAC<br>40 230VAC 40 230VAC<br>20 20<br>0 0<br>0 20 40 60 80 100 0 20 40 60 80 100<br>Load (%) Load (%)<br>Figure 5<br>GSP500PS48<br>100<br>80<br>60<br>115VAC<br>40<br>230VAC<br>20<br>0<br>0 20 40 60 80 100<br>Load (%)<br>Efficiency (%)<br>Efficiency (%)<br>Efficiency (%)<br>**----- End of picture text -----**<br> 4 **AC-DC power supplies** ## GSP500 series ## **Environmental** **==> picture [553 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Operating temperature -20 +70 °C Start up at -40°C. See derating curve, fig. 6<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Operating temperature|-20||+70|°C|Start up at -40°C. See derating curve, fg. 6| |Storage temperature|-40||+85|°C|| |Cooling|20.4 (12)|||m3/h (CFM)|GSP500PSxx models| |Humidity|5||95|%RH|Non-condensing| |Operating altitude|||5000|m|| |Acoustic fan noise<br>GSP500PSxx models||59.9||Lw dB (A)|Full speed| |||52.1|||Mid speed| |||36.6|||Low speed| |Shock|3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47||||| |Vibration|Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| ## Temperature derating curve Figure 6 **==> picture [276 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 500<br>Fan-cooled 20.4m [3] /h<br>250<br>180<br>90 Convec�on-cooled<br>0<br>-40 -20 0 +50 +70<br>Ambient temperature (ºC)<br>Some specifica�on<br>Output power (W)<br>parameters may not be met<br>**----- End of picture text -----**<br> |**EMC: emissions**|**EMC: emissions**||| |---|---|---|---| |Phenomenon|Standard|Test level|Notes & conditons| |Conducted|EN55011/32|Class B|| |Radiated|EN55011/32|Class A|| |||Class B|With 1 Turn Wurth 742 712 22 core or similar on output lead| |Harmonic fuctuations|EN61000-3-3||| 5 **AC-DC power supplies** ## GSP500 series ## **EMC: immunity** **==> picture [553 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |Low voltage PSU EMC|EN61204-3|High severity level|as below|| |Harmonic current|EN61000-3-2|Class A||All models| |||Class C||>50W| |Radiated|EN61000-4-3|3|A|| |EFT|EN61000-4-4|3|A|| |Surges|EN61000-4-5|Installation class 3|A|| |Conducted|EN61000-4-6|3|A|| |Dips and interruptions|EN55035<br>(100VAC)|Dip >95% (0VAC), 8.3ms|A|| |||Dip 30% (70VAC), 416ms|A|| |||Dip >95% (0VAC), 4160ms|B|| ||EN55035<br>(240VAC)|Dip >95% (0VAC), 10ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Dip >95% (96VAC), 5000ms|B|| ||EN60601-1-2<br>(100VAC)|Dip >95% (0VAC), 10ms|A|| |||Dip 60% (40VAC), 100ms|A|Derate Output Power to 250W| |||Dip 30% (70VAC), 500ms|A|| |||Dip >95% (0VAC), 5000ms|B|| ||EN60601-1-2<br>(240VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 60% (96VAC), 100ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Dip >95% (0VAC), 5000ms|B|| ## **Safety approvals** **==> picture [554 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & conditions<br>IEC60950-1 & IEC62368-1 Information Technology<br>CB report<br>IEC60601-1 Including Risk Management Medical<br>UL62368-1, CSA62368-1 via cUL Information Technology<br>UL<br>ANSI/AAMI ES60601-1 & CSA C22.2, No.60601-1 Medical<br>EN62368-1 Information Technology<br>TUV<br>EN60601-1 Medical<br>Equipment protection class Class I<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>Isolation Means of Protection Category<br>Primary to Secondary 2 x MOPP (Means of Patient Protection)<br>IEC60601-1<br>Primary to Earth 1 x MOPP (Means of Patient Protection)<br>**----- End of picture text -----**<br> 6 **AC-DC power supplies** ## GSP500 series ## **Signal & controls** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Notes & conditions<br>**----- End of picture text -----**<br> |Certfcaton|Notes & conditons| |---|---| ||| |Power fail (PF)|Open collector referenced to negative sense, transistor normally on when power is good (see fg. 7); power is considered good when<br>PFC bulk capacitor voltage is normal. PF: Provides ≥ 5ms warning of loss of output from power failure.| |Inhibit|Uncommitted isolated optocoupler diode, powered diode inhibits both V1 and fan supply (see fg. 8). During inhibit the standby supply<br>and current should be limited to 1A for thermal reasons.| |Output good|LED Indicator| |Fan speed control<br>GSP500PSxx-EF Models|The fan speed is set to one of 4 states (high, mid, low or off) dependant on the internal power supply ambient temperature, input<br>voltage and output load at any given time.| |Standby supply|5V/2A Isolated supply present when AC applied.| |Remote sense|Compensates for 0.5V total voltage drop.| |Current share|Optional, on ‘P’ version only. Connecting pins 5 or 6 on one unit to pins 5 or 6 on another like voltage unit will force the current to be<br>shared within 10% between the two outputs. Up to three units can share current. (see fg. 9)| ## Power fail (PF) ## Figure 7 ## Remote On/Off (Inhibit) **==> picture [26 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 8<br>**----- End of picture text -----**<br> **==> picture [541 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> INHIBIT HI INHIBIT LOW<br>POWER SUPPLY Max 10mA1.5K POWER SUPPLY 1.5K POWER SUPPLY<br>5V Standby 5V Standby 5V Standby<br>Pin 9 Pin 9 Pin 9<br>10K Min 0.5mA, max 10mA<br>100 R<br>500µA 100 R<br>Typical 500µA(max allowable 600µA) Pin 3PF Collector Inhibit Hi Pin 7 Inhibit Hi<br>Pin 7<br>3.2V<br>Transistor On (<0.8V): max<br>POWER OK<br>(-sense)PF Emi�er Pin 2 Transistor Off (>3.5V): POWER NOT OK Inhibit LoPin 8 Inhibit LoPin 8<br>5V Standby Return<br>5V Standby Return Pin 10<br>5V Standby Pin 10<br>Return Pin 10<br>J301 Logic Connector Chassis J301 Logic Connector Chassis J301 Logic Connector<br>Signal High: Power Supply OFF Signal High: Power Supply ON<br> Low or Floa�ng: Power Supply ON Low or Floa�ng: Power Supply OFF<br>**----- End of picture text -----**<br> ## Current share Figure 9 **==> picture [230 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> GSP500PSXX GSP500PSXX GSP500PSXX<br>V1 Output V1 Output V1 Output<br>- + Current - + Current - +<br>Share Share<br>Pin 5,6<br>- +<br>Load<br>+ Sense - Sense<br>- Sense + Sense<br>- Sense + Sense<br>**----- End of picture text -----**<br> 7 **AC-DC power supplies** ## GSP500 series **==> picture [157 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical details<br>**----- End of picture text -----**<br> **==> picture [30 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> GSP500<br>**----- End of picture text -----**<br> **==> picture [539 x 566] intentionally omitted <==** **----- Start of picture text -----**<br> 33.00 (1.30) x 2<br>A A<br>5.00 (0.20)<br>143.40 (5.65)<br>Logic Connector<br>152.40 (6.00)<br>15.9 (0.63) X2<br>1 3 910 21<br>Fan Connector<br>LED 28.90 (1.14) M4 SCREW-2x<br>TORQUE: 1.2Nm (10.62lbs-in) Max.<br>VOUT (-)<br>19.45 (0.77)<br>101.60 (4.00) VOUT (+)<br>N<br>L<br>143.40 (5.65)<br>0.50 (0.02)<br>41.90 (1.65) A DETAIL A<br>Airflow A<br>Dat 12CFMirec�on 24.90 (0.98) 33.00 (1.30) Moun�ng Hole8 PLCS M3 X 0.5<br>3.8 (0.15) MAX Penetra�on<br>Torque: 5lb/in (0.6Nm)<br>5.00 (0.20)<br>33.00 (0.21)<br>152.40 (6.00)<br>137.40 (5.41) x 2<br>A A<br>101.60 (4.00)<br>60.00 (2.36)<br>CL<br>A A<br>10.00 (0.39)X2<br>Fan connector [(3) ] Logic connector [(3) ] for standard versions Logic connector [(3) ] for Current Share versions -P<br>S3B-PH-KL (LF) JST B10B-PHDSS JST B10B-PHDSS<br>Pin Function Pin Single Pin Single Pin Single Pin Single<br>1 +12V 1 +Sense 6 No connection 1 +Sense 6 Current share<br>2 N/C 2 -Sense 7 +Inhibit 2 -Sense 7 +Inhibit<br>3 GND 3 Power fail 8 -Inhibit 3 Power fail 8 -Inhibit<br>4 No connection 9 +5V standby 4 No connection 9 +5V standby<br>5 No connection 10 -5V standby 5 Current share 10 -5V standby<br>**----- End of picture text -----**<br> ## Notes: 1. All dimensions in mm (inches). 2. Tolerance x.x (x.xx) = 0.50 (0.02); x.xx (x.xxx) = 0.25 (0.01) or equivalent. Logic connector J301 mates with JST housing PHDR-10VS and SPHD001T-P0.5 crimp terminals. 3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp terminals 8 **AC-DC power supplies** ## GSP500 series **==> picture [547 x 602] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical details<br>GSP500-EF<br>33.00 (1.30) X 2<br>A A<br>5.00 (0.20)<br>143.40 (5.65)<br>170.40 (6.71) LOGIC CONNECTOR<br>2.00 (0.08) 1 3 910 21 15.90 (0.63)<br>FAN CONNECTOR<br>LED 28.90 (1.14) M4 SCREW-2XTORQUE: 1.2Nm (10.62lbs-in) Max.<br>101.60 (4.00)<br>VOUT (-)<br>19.45 (0.77)<br>VOUT (+)<br>48.94 (1.93) M3.5 SCREW 9.5mm CENTER<br>TORQUE: 1.2Nm (10.62lbs-in) Max.<br>N<br>L<br>20.95 (0.82)<br>177.79 (7.00)<br>0.50 (0.02) 143.40 (5.65)<br>AIRFLOW 41.90 (1.65) A DETAIL A<br>A<br>DIRECTION 24.90 (0.98) 33.00 (1.30) Moun�ng Hole8 PLCS M3 X 0.5<br>3.8 (0.15) MAX Penetra�on<br>Torque: 0.6 Nm (5 lb/in)<br>5.00 (0.20)<br>5.39 (0.21)<br>152.40 (6.00)<br>137.40 (5.41) X 2<br>A A<br>101.60 (4.00)<br>60.00 (2.36)<br>CL<br>A A<br>10.00 (0.39)X2<br>Fan connector [(3) ] Logic connector [(3) ] for standard versions Logic connector [(3) ] for Current Share versions -P<br>S3B-PH-KL (LF) JST B10B-PHDSS JST B10B-PHDSS<br>Pin Function Pin Single Pin Single Pin Single Pin Single<br>1 +12V 1 +Sense 6 No connection 1 +Sense 6 Current share<br>2 N/C 2 -Sense 7 +Inhibit 2 -Sense 7 +Inhibit<br>3 GND 3 Power fail 8 -Inhibit 3 Power fail 8 -Inhibit<br>4 No connection 9 +5V standby 4 No connection 9 +5V standby<br>5 No connection 10 -5V standby 5 Current share 10 -5V standby<br>**----- End of picture text -----**<br> ## Notes: 1. All dimensions in mm (inches). 2. Tolerance x.x (x.xx) = 0.50 (0.02); x.xx (x.xxx) = 0.25 (0.01) or equivalent. Logic connector J301 mates with JST housing PHDR-10VS and SPHD001T-P0.5 crimp terminals. 3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp terminals 9 **AC-DC power supplies** ## GSP500 series ## **Thermal considerations** In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See below for component locations. |Temperature measurements (at maximum ambient)|Temperature measurements (at maximum ambient)| |---|---| |Component|Max temperature °C| |**T1 coil**|+120°C| |**L3 coil**|+120°C| |**Q7 body**|+120°C| |**Q102 body**|+120°C| |**C20**|+105°C| |**C102**|+105°C| ## **Service life** The estimated service life of the GSP500PSxx Series is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative service life in 24/7 operation. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. ## Estimated service life vs component temperature **==> picture [554 x 333] intentionally omitted <==** **----- Start of picture text -----**<br> 70000 350000<br>60000 300000<br>50000 250000<br>40000 200000<br>30000 150000<br>20000 100000<br>10000 50000<br>0 0<br>+105 +95 +85 +75 +65 +55 +105 +95 +85 +75 +65 +55<br>C20 Temperature (°C) C102 Temperature (°C)<br>Q102<br>C20<br>C102<br>Q7<br>T1<br>L3<br>Life�me (Hrs) Life�me (Hrs)<br>**----- End of picture text -----**<br> 19 May 2026 10
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →