Image not available
Illustrative purposes only
GSM60E48-P1J
AC/DC Power Supply, Medical, 1 Output, 60 W, 48 VDC, 1.25 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:60W; Output Voltage - Output 1:48V; Output Current - Output 1:1.25A; Output Voltage - Outp; Available until stocks are exhausted Alternative available
- SVHC: No SVHC (12-Jan-2017)
- Plug Type: EU
- Product Range: GSM60E Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 11mm
- Output Power Max: 60W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 29.78 € |
| Current stock | 10+ |
| Lead time | 30 days |
60W AC-DC Reliable Green Slim Wall-mounted Medical Adaptor **GSM60E series**
**IP22** + + ~~Z~~ ICBHICE C2) Cod leas) LAd ■ Features ■ Applications • Ultra slim, compact size • Blood glucose meter • Medical safety approved (2 x MOPP) according to • Blood pressure meter • EN60601-1/EN60601-1-11 Nebulizer • • Extremely Low leakage current Inhaler • 2 pole EURO plug, Class Ⅱ —_ power unit • Portable medical device • • No load power consumption <0.15W Sleep apnea devices • Energy efficiency Level Ⅵ (except5~9VforLevel Ⅴ ) • -30~+70 ℃ wide range working temperature •
• •
## ■
compact and convenient for carry. GSM60E is aclass Ⅱ — power unit (no FG) equipped with the standard 2-Pin
Ⅴ
**==> picture [13 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
**==> picture [6 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
{<br>**----- End of picture text -----**<br>
ψ× ψ×
_File Name:GSM60E-SPEC 2018-08-07_
60W AC-DC Reliable Green Slim Wall-mounted Medical Adaptor
## **GSM60E series**
## **SPECIFICATION**
|**SPECIFICATION**|**SPECIFICATION**||||
|---|---|---|---|---|
|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**VOLTAGE RANGE**<br>**Note.7**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT (max.)**<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>**LEAKAGE CURRENT(max.)**<br>**OVERLOAD**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**ISOLATION LEVEL**<br>**ENVIRONMENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**PROTECTION**<br>**OVER VOLTAGE**<br>**SAFETY STANDARDS**<br>**STORAGE TEMP., HUMIDITY**<br>**LIFE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>I/P-O/P:5656VDC<br>3 years : 100% load 40<br>, 8hours / day<br>℃<br>400Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>75.5*32*47.5mm (L*W*H)<br>200g ; 60pcs / 13kg / CARTON<br>**PLUG**<br>**CABLE**<br>Pimary - Secondary: 2 x MOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55011, EN60601-1-2<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conductedemission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>1.5A / 115VAC 0.8A / 230VAC<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>TUV EN60601-1/EN60601-1-11,<br>approved<br>EAC TP TC 004<br>105 ~ 160% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>110 ~ 140% rated output voltage<br>Touch current < 100 A/264VAC<br>μ<br>**SAFETY &**<br>**EMC**<br>**(Note. 8)**<br>**OTHERS**<br>**NOTE**<br>**CONNECTOR**<br>℃<br>50A / 115VAC 100A / 230VAC<br>Cold start<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>See page 4 5 ; other type available by customer requested<br>~<br>See page 4 5 ; other type available by customer requested<br>~<br>**Standard**<br>**Standard**<br>EN61000-3-2<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 3, 2KV/Line-Line<br>Level 4, 30A/m<br>Level 2, 3V<br>Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~6GHz)<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>-30 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>Protection type : Clamp by zener diode, output short<br>500ms, 30ms, 10ms/230VAC 500ms, 30ms, 10ms/115VAC at full load<br>5V<br>9V<br>7.5V<br>12V<br>15V<br>18V<br>24V<br>48V<br>GSM60E05<br>GSM60E09<br>GSM60E07<br>GSM60E12<br>GSM60E15<br>GSM60E18<br>GSM60E24<br>GSM60E48<br>**GSM60E05-P1J GSM60E07-P1J GSM60E09-P1J GSM60E12-P1J GSM60E15-P1J GSM60E18-P1J GSM60E24-P1J GSM60E48-P1J**<br>6A<br>5.5A<br>6A<br>4.5A<br>4A<br>3.33A<br>2.5A<br>1.25A<br>0 ~ 6A<br>0 ~ 5.5A<br>0 ~ 6A<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 3.33A<br>0 ~ 2.5A<br>100mVp-p<br>100mVp-p<br>100mVp-p<br>100mVp-p<br>120mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>30W<br>49.5W<br>45W<br>54W<br>60W<br>60W<br>60W<br>60W<br>0 ~ 1.25A<br>80%<br>87%<br>85%<br>88%<br>88%<br>88%<br>88%<br>90%<br>Level 3,<br>Line-Line<br>2KV<br>,1KV ineterconnect Lines at 100KHz rate<br>EE ———————<br>RR<br>Re<br>Rs<br>SR~~a ———=~~<br>~~——————~~<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)||**GSM60E05-P1J GSM60E07-P1J GSM60E09-P1J GSM60E12-P1J GSM60E15-P1J GSM60E18-P1J GSM60E24-P1J GSM60E48-P1J**|||
||**SAFETY MODEL NO.**|GSM60E05<br>GSM60E09<br>GSM60E07<br>GSM60E12<br>GSM60E15<br>GSM60E18<br>GSM60E24<br>GSM60E48|||
||**DC VOLTAGE**<br>**Note.2**|5V<br>9V<br>7.5V<br>12V<br>15V<br>18V<br>24V<br>48V|||
||**RATED CURRENT**|6A<br>5.5A<br>6A<br>4.5A<br>4A<br>3.33A<br>2.5A<br>1.25A|||
||**CURRENT RANGE**|0 ~ 6A<br>0 ~ 5.5A<br>0 ~ 6A<br>0 ~ 4.5A<br>0 ~ 4A<br>0 ~ 3.33A<br>0 ~ 2.5A<br>0 ~ 1.25A|||
||**RATED POWER (max.)**|30W<br>49.5W<br>45W<br>54W<br>60W<br>60W<br>60W<br>60W|||
||**RIPPLE & NOISE (max.) Note.3**|100mVp-p<br>100mVp-p<br>100mVp-p<br>100mVp-p<br>120mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p|||
||**VOLTAGE TOLERANCE Note.4**|±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%|||
||**LINE REGULATION**<br>**Note.5**|±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%|||
||**LOAD REGULATION**<br>**Note.6**|±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%|||
||**SETUP, RISE, HOLD UP TIME**|500ms, 30ms, 10ms/230VAC 500ms, 30ms, 10ms/115VAC at full load|||
||**VOLTAGE RANGE**<br>**Note.7**|80 ~ 264VAC 113 ~ 370VDC|||
||**FREQUENCY RANGE**|47 ~ 63Hz|||
||**EFFICIENCY (Typ.)**|80%<br>87%<br>85%<br>88%<br>88%<br>88%<br>88%<br>90%|||
||**AC CURRENT**|1.5A / 115VAC 0.8A / 230VAC|||
||**INRUSH CURRENT (max.)**|50A / 115VAC 100A / 230VAC<br>Cold start|||
||**LEAKAGE CURRENT(max.)**<br>EE|Touch current < 100 A/264VAC<br>μ<br>———————|||
||**OVERLOAD**<br>EE|105 ~ 160% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>———————|||
||**OVER VOLTAGE**<br>EE<br>RR|110 ~ 140% rated output voltage<br>Protection type : Clamp by zener diode, output short<br>———————|||
||**WORKING TEMP.**<br>EE <br>RR<br>Re|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br> ———————|||
||**WORKING HUMIDITY**<br>RR<br>Re<br>Rs|20% ~ 90% RH non-condensing|||
||**STORAGE TEMP., HUMIDITY**<br>Re<br>Rs|-30 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||
||**TEMP. COEFFICIENT**<br>Rs|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 40<br>)|||
||**VIBRATION**<br>SR|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>|||
||**SAFETY STANDARDS**<br>SR|TUV EN60601-1/EN60601-1-11,<br>approved<br>EAC TP TC 004<br>|||
||**ISOLATION LEVEL**<br>SR|Pimary - Secondary: 2 x MOPP<br>|||
||**WITHSTAND VOLTAGE**<br>|I/P-O/P:5656VDC<br>|||
||**ISOLATION RESISTANCE**<br>~~a~~|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~a ———=~~|||
||**LIFE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~a~~<br>~~——————~~|**Parameter**<br>~~a ———=~~|**Standard**<br>~~———=~~|**Test Level / Note**<br>~~———=~~|
|||Conductedemission<br>~~a ———=~~|EN55011 (CISPR11)<br>~~———=~~|Class B<br>~~———=~~|
|||Radiated emission<br>~~a ———=~~|EN55011 (CISPR11)<br>~~———=~~|Class B<br>~~———=~~|
|||Harmonic current<br>~~a ———=~~|EN61000-3-2<br>~~———=~~|Class A<br>~~———=~~|
|||Voltage flicker<br>~~a ———=~~|EN61000-3-3<br>~~———=~~|-----<br>~~———=~~|
|||EN55011, EN60601-1-2<br>~~a ———=~~|||
|||**Parameter**|**Standard**|**Test Level / Note**|
|||ESD|EN61000-4-2|Level 4, 15KV air ; Level 4, 8KV contact|
|||RF field susceptibility|EN61000-4-3|Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~6GHz)|
|||EFT bursts|EN61000-4-4|Level 3,<br>Line-Line<br>2KV<br>,1KV ineterconnect Lines at 100KHz rate|
|||Surge susceptibility|EN61000-4-5|Level 3, 2KV/Line-Line|
|||Conducted susceptibility|EN61000-4-6|Level 2, 3V|
|||Magnetic field immunity|EN61000-4-8|Level 4, 30A/m|
|||Voltage dip, interruption<br>~~——————~~|EN61000-4-11<br>~~——————~~|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|
|||3 years : 100% load 40<br>, 8hours / day<br>℃<br>~~——————~~|||
||**MTBF**<br>~~——————~~|400Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>~~——————~~|||
||**DIMENSION**<br>~~——————~~|75.5*32*47.5mm (L*W*H)<br>~~——————~~|||
||**PACKING**<br>~~——————~~|200g ; 60pcs / 13kg / CARTON<br>~~——————~~|||
||**PLUG**<br>~~——————~~|See page 4 5 ; other type available by customer requested<br>~<br>~~——————~~|||
||**CABLE**|See page 4 5 ; other type available by customer requested<br>~|||
||℃<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)||||
_File Name:GSM60E-SPEC 2018-08-07_
**GSM60E series**
60W AC-DC Reliable Green Slim Wall-mounted Medical Adaptor
**==> picture [485 x 600] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating Curve Static Characteristics<br>100<br>90<br>100<br>80<br>70<br>70<br>50 60<br>50<br>40<br>-30 10 20 30 40 50 70 80 100 115 120 130 140 160 180 200 220 240 264<br>Ta ( ℃ ) INPUT VOLTAGE<br>Mechanical Specification Unit:mm<br>75.5<br>UL2468 16AWG 1000+150/-0mm for 5~18V<br>UL2468 18AWG 1500+150/-0mm for 24~48V<br>2 pole EURO plug<br>o i e<br>DC output plug<br>◎ Standard plug: P1J Unit:mm<br>P1J Pin Assignment<br>a<br>5.5 11 ±0.5mm C"+"<br>2.1<br>Outside Inside<br>LOAD (%) LOAD (%)<br>32<br>47.5<br>**----- End of picture text -----**<br>
_File Name:GSM60E-SPEC 2018-08-07_
60W AC-DC Reliable Green Slim Wall-mounted Medical Adaptor
## **GSM60E series**
◎ Optional DC plug:
|Tuning Fork Style<br>~~rr~~|Tuning Fork Style<br>~~rr~~|Type No.<br>~~rr~~<br>~~ee~~|A<br>~~rr~~|A<br>~~rr~~|B<br>~~rr~~|B<br>~~rr~~|C<br>~~rr~~|C<br>~~rr~~|
|---|---|---|---|---|---|---|---|---|
||||OD<br>~~rr~~||ID<br>~~rr~~||L<br>~~rr~~||
|B<br>A<br>~~rr~~<br>™~~~ofe~~<br>7|C<br>(Straight)<br>~~rr~~<br>~~a~~<br>~~fe~~<br>~~a~~|P1I<br>~~rr~~<br>~~ee~~<br>~~a~~|5.5<br>~~rr~~<br>~~a~~||2.1<br>~~rr~~<br>~~a~~||9.5<br>~~rr~~<br>~~a~~||
|||P1L<br>~~rr~~<br>~~ee~~<br>~~a~~|5.5<br>~~rr~~<br>~~a~~||2.5<br>~~rr~~<br>~~a~~||9.5<br>~~rr~~<br>~~a~~||
|||P1M<br>~~a~~<br>~~a~~|5.5<br>~~a~~<br>~~a~~||2.5<br>~~a~~<br>~~a~~||11.0<br>~~a~~<br>~~a~~||
||C<br>(Right-angled)<br>~~fe~~<br>~~a~~|P1IR<br>~~a~~|5.5<br>~~a~~||2.1<br>~~a~~||9.5<br>~~a~~||
|||P1JR<br>~~a~~|5.5<br>~~a~~||2.1<br>~~a~~||11.0<br>~~a~~||
|||P1LR<br>~~a~~<br>~~—~~|5.5<br>~~a~~<br>~~—~~||2.5<br>~~a~~<br>~~—~~||9.5<br>~~a~~<br>~~—~~||
|||P1MR<br>~~a~~<br>~~—~~|5.5<br>~~a~~<br>~~—~~||2.5<br>~~a~~<br>~~—~~||11.0<br>~~a~~<br>~~—~~||
|Barrel Style<br>7~~a~~<br>~~rr~~||Type No.<br>~~a~~<br>~~—~~<br>~~rr~~|A<br>~~a~~<br>~~—~~<br>~~rr~~||B<br>~~a~~<br>~~—~~<br>~~rr~~||C<br>~~a~~<br>~~—~~<br>~~rr~~||
||||OD<br>~~rr~~<br>~~ee~~||ID<br>~~rr~~<br>~~ee~~||L<br>~~rr~~||
|A<br>B<br>~~rr~~<br>e~~w~~<br>|<br>pS|C<br>(Straight)<br>~~rr~~<br>~~——~~<br>||P2I<br>~~rr~~<br>~~ee~~<br>~~——~~|5.5<br>~~rr~~<br>~~ee~~<br>~~ee~~<br>~~——~~||2.1<br>~~rr~~<br>~~ee~~<br>~~ee~~<br>~~——~~||9.5<br>~~rr~~<br>~~ee~~<br>~~——~~||
|||P2J<br>~~——~~|5.5<br>~~ee ~~<br>~~——~~||2.1<br> ~~ee~~<br>~~——~~||11.0<br>~~——~~||
|||P2L<br>~~——~~|5.5<br>~~——~~||2.5<br>~~——~~||9.5<br>~~——~~||
|||P2M<br>~~——~~<br>~~————~~<br>|5.5<br>~~——~~<br>~~———~~<br>||2.5<br>~~——~~<br>~~———~~<br>||11.0<br>~~——~~<br>~~———~~<br>||
||C<br>(Right-angled)<br>~~——~~<br>|~~6~~|P2IR<br>~~——~~<br>~~————~~<br>~~Ee~~|5.5<br>~~——~~<br>~~———~~<br>~~Ee~~||2.1<br>~~——~~<br>~~———~~<br>~~Ee~~||9.5<br>~~——~~<br>~~———~~<br>~~Ee~~||
|||P2JR<br>~~——~~<br>~~————~~<br>~~Ee~~|5.5<br>~~——~~<br>~~———~~<br>~~Ee~~||2.1<br>~~——~~<br>~~———~~<br>~~Ee~~||11.0<br>~~——~~<br>~~———~~<br>~~Ee~~||
|||P2LR<br>~~————~~<br>~~Ee~~<br>~~ee~~|5.5<br>~~———~~<br>~~Ee~~<br>~~ee~~<br>~~ee~~||2.5<br>~~———~~<br>~~Ee~~<br>~~ee~~<br>~~ee~~||9.5<br>~~———~~<br>~~Ee~~<br>~~ee~~||
|||P2MR<br>~~————~~<br>~~Ee~~<br>~~ee~~<br>~~——~~|5.5<br>~~———~~<br>~~Ee~~<br>~~ee~~<br>~~ee ~~<br>~~——~~||2.5<br>~~———~~<br>~~Ee~~<br>~~ee~~<br> ~~ee~~<br>~~——~~||11.0<br>~~———~~<br>~~Ee~~<br>~~ee~~<br>~~——~~||
|Lock Style<br>| ~~6 ~~<br>pS<br>SS||Type No.<br>~~————~~<br> ~~Ee~~<br>~~——~~|A<br>~~———~~<br>~~Ee~~<br>~~——~~||B<br>~~———~~<br>~~Ee~~<br>~~——~~||C<br>~~———~~<br>~~Ee~~<br>~~——~~||
||||OD<br>~~——~~<br>~~ee~~||ID<br>~~——~~||L<br>~~——~~||
|A<br>B<br>C<br>Locking<br>SWITCHCRAFT original or equivalent<br>pS<br>~~= ~~<br>SS<br>~~re~~||P2S(S761K)<br>P2K(761K)<br>~~——~~<br> ~~ee~~<br>~~——~~|5.53<br>5.53<br>~~——~~<br>~~ee~~<br>~~ee~~<br>~~——~~||2.03<br>2.54<br>~~——~~<br>~~ee~~<br>~~——~~||12.06<br>12.06<br>~~——~~<br>~~ee~~<br>~~——~~||
|||P2C(S760K)<br>P2D(760K)<br>~~——~~<br>~~—~~<br>|5.53<br>5.53<br>~~ee~~<br>~~——~~<br>~~—~~<br>||2.03<br>2.54<br>~~——~~<br>~~—~~<br>||9.52<br>9.52<br>~~——~~<br>~~—~~<br>||
|Min. Pin Style<br>~~re~~<br>~~||Type No.<br>~~—~~<br>~~ee~~<br>|A<br>~~—~~<br>~~ee~~<br>||B<br>~~—~~<br>~~ee~~<br>||C<br>~~—~~<br>~~ee~~<br>||
||||OD<br>~~—~~<br>~~ee~~<br>||ID<br>~~—~~<br>~~ee~~<br>||L<br>~~—~~<br>~~ee~~<br>||
|C<br>B<br>A<br>EIAJ equivalent<br>~~re ~~<br>a~~||P3A<br>~~—~~<br>~~ee~~<br>~~——~~|2.35<br>~~—~~<br>~~ee~~<br>~~——~~||0.7<br>~~—~~<br>~~ee~~<br>~~——~~||11.0<br>~~—~~<br>~~ee~~<br>~~——~~||
|||P3B<br>~~—~~<br> ~~ee~~<br>~~——~~|4.0<br>~~—~~<br>~~ee~~<br>~~——~~||1.7<br>~~—~~<br>~~ee~~<br>~~——~~||11.0<br>~~—~~<br>~~ee~~<br>~~——~~||
|||P3C<br>P3B<br> ~~ee~~<br>~~——~~|4.0<br>4.75<br>~~ee~~<br>~~——~~||1.7<br>1.7<br>~~ee~~<br>~~——~~||11.0<br>11.0<br>~~ee~~<br>~~——~~||
|Center Pin Style<br> <br> a ~~<br>~~RARE~~<br>C~~e~~||Type No.<br> ~~ee~~<br> ~~——~~<br>~~RARE~~<br>~~Se~~|A<br>~~ee~~<br>~~——~~<br>~~RARE~~|B<br>~~ee~~<br>~~——~~<br>~~RARE~~|B<br>~~ee~~<br>~~——~~<br>~~RARE~~|C<br>~~ee~~<br>~~——~~<br>~~RARE~~||D<br>~~ee~~<br>~~——~~<br>~~RARE~~|
||||OD<br>~~ee~~<br><br>~~RARE~~<br>~~Se~~|ID<br>~~ee~~<br><br>~~RARE~~<br>~~Se~~||L<br>~~ee~~<br><br>~~RARE~~<br>~~Se~~||Center Pin<br>~~ee~~<br><br>~~RARE~~<br>~~Se~~|
|A<br>B<br>D<br>C<br>EIAJ equivalent<br>~~RARE~~<br>~~re~~<br>~~r~~ ~~|~~<br>C~~e~~||P4A<br>P4B<br>~~RARE~~<br>~~Se~~|5 5.<br>6.5<br>~~RARE~~<br>~~Se~~|3.4<br>4.4<br>~~RARE~~<br>~~Se~~||11.0<br>11.0<br>~~RARE~~<br>~~Se~~||1.0<br>1.4<br>~~RARE~~<br>~~Se~~|
|||P4C<br>P4B<br>~~Se~~|6.5<br>7.4<br>~~Se~~|4.4<br>5.1<br>~~Se~~||11.0<br>11.0<br>~~Se~~||1.4<br>0.6<br>~~Se~~|
|Min. DIN 3 Pin with Lock (male)<br>C~~e~~<br>~~SL~~||Type No.<br>~~Se~~<br>~~SL~~|Pin Assignment<br>~~Se~~<br>~~SL~~||||||
||||PIN No.<br>~~Se~~<br>~~SL~~||Output<br>~~Se~~<br>~~SL~~||||
|KYCON KPPX 3P equivalent<br>-<br>2<br>1<br>3<br>~~SL~~<br>e~~®~~||R6B<br>~~SL~~|1<br>~~SL~~||+Vo<br>~~SL~~||||
||||2<br>3||-Vo<br>+Vo||||
_File Name:GSM60E-SPEC 2018-08-07_
60W AC-DC Reliable Green Slim Wall-mounted Medical Adaptor **GSM60E series**
**==> picture [459 x 311] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Assignment<br>Min. DIN 4 Pin with Lock (male) Type No.<br>— PIN No. Output<br>1 +Vo<br>2 3 2 -Vo<br>R7B<br>1 4 3 -Vo<br>KYCON KPPX-4P equivalent<br>"Wr; ema fll S14 [> ==—_|—— 4 +Vo<br>Pin Assignment<br>Stripped and tinned leads Type No.<br>a PIN No. Output<br>L<br>1 1 +Vo<br>2 ( Ribbed )<br>L1 by customer<br>Length of Land L1 by request<br>2 -Vo<br>(MW’s standard length, L: 25 mm, L1: 10 mm) ( Letter )<br><*|-<br>Installation Manual<br>Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br>
_File Name:GSM60E-SPEC 2018-08-07_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →