Image not available
Illustrative purposes only
GSM160A12-R7B
AC/DC Power Supply, Medical, 1 Output, 138 W, 12 VDC, 11.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:138W; Output Voltage - Output 1:12V; Output Current - Output 1:11.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connec
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: GSM160A Series
- No. of Outputs: 1 Output
- Output Connector: 4 Way DIN
- Output Power Max: 138W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 11.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 58.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
160W AC-DC Reliable Green Medical Adaptor **GSM160A series**
**==> picture [489 x 314] intentionally omitted <==**
**----- Start of picture text -----**<br>
User’s Manual Video<br>eas Met Oy iy i:<br>Sees | |<br>peas ee Stas npe<br>Cz)A) @) Energ etiquey Verified Verifié = cA US C B<br>uk BS EN/EN60601-1 ANSI/AAMI ES60601-1 IEC60601-1 (Ba) + +<br>FHL FEC € es JOG<br>TPTC004<br>Features Applications<br>* 3 pole AC inlet IEC320-C14, Class Ⅰ power unit * Mobile clinical workstation<br>* Medical safety approved (2 x MOPP) according to * Oral irrigator<br>ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1 - Portable hemodialysis machine<br>* Extremely low leakage current * Breath Machine<br>* No load power consumption<0.15W - Medical computer monitor<br>* Energy efficiency level VI and meet CoC Version 5<br>* -30~+70 ℃ wide range working temperature<br>* | ge wonsng temp ■ GTIN CODE<br>Protections: Short circuit / Overload / Over voltage / Over temperature<br>**----- End of picture text -----**<br>
> https://www.meanwell.com/serviceGTIN.aspx ~~____~~
## **Description**
## **{**
_File Name:GSM160A-SPEC 2022-11-21_
**==> picture [511 x 693] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|160W|AC-DC|Reliable|Green|Medical Adaptor|GSM160A|series|
|MEAN|WELL|Ceeeeeeeeeeeeeeeeeeeeeeeee|reer reer reer reer|r eee|eee|ee|eee|
|SPECIFICATION|
|ORDER NO.|GSM160A12-R7B|GSM160A15-R7B|GSM160A20-R7B|GSM160A24-R7B|GSM160A48-R7B|
|SAFETY MODEL NO.|GSM160A12|GSM160A15|GSM160A20|GSM160A24|GSM160A48|
|DC VOLTAGE|Note.2|12V|15V|20V|24V|48V|
|RATED CURRENT|11.5A|9.6A|8A|6.67A|3.34A|
|CURRENT RANGE|0 ~ 11.5A|0 ~ 9.6A|0 ~ 8A|0 ~ 6.67A|0 ~ 3.34A|
|RATED POWER (max.)|138W|144W|160W|160W|160W|
|OUTPUT|RIPPLE & NOISE (max.) Note.3|80mVp-p|100mVp-p|100mVp-p|120mVp-p|150mVp-p|
|VOLTAGE TOLERANCE Note.4|±5.0%|±5.0%|±4.0%|±3.0%|±3.0%|
|LINE REGULATION|Note.5|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|
|LOAD REGULATION|±5.0%|±5.0%|±4.0%|±3.0%|±3.0%|
|SETUP, RISE TIME|Note.6|2000ms, 50ms / 230VAC 2500ms, 50ms / 115VAC at full load|
|HOLD UP TIME (Typ.)|24ms / 230VAC 24ms / 115VAC at full load|
|==|
|VOLTAGE RANGE|Note.7|80 ~ 264VAC|
|FREQUENCY RANGE|47 ~ 63Hz|
|POWER FACTOR (Typ.)|12V,15V:PF>0.93 / 230VAC|20V 24V,|,48V:PF>0.94|/ 230VAC PF>0.98|/ 115VAC at full load|
|EFFICIENCY (Typ.)|90%|91%|92.5%|93%|94%|
|INPUT|
|AC CURRENT (Typ.)|1.85A / 115VAC 1A / 230VAC|
|INRUSH CURRENT (Typ.)|Cold start|90A / 115VAC 110A / 230VAC|
|LEAKAGE CURRENT(max.)|Earth leakage current < 175μA/264VAC , Touch current <90μA/264VAC|
|105 ~ 150% rated output power|
|OVERLOAD|
|Protection type : Hiccup mode, recovers automatically after fault condition is removed|
|PROTECTION|
|105 ~ 135% rated output voltage|
|OVER VOLTAGE|
|Protection type : Shut down o/p voltage, re-power on to recover|
|OVER TEMPERATURE|Shut down o/p voltage, re-power on to recover|
|WORKING TEMP.|-30 ~ +70℃|(Refer to "Derating Curve")|
|WORKING HUMIDITY|20% ~ 90% RH non-condensing|
|ENVIRONMENT|STORAGE TEMP., HUMIDITY|-40 ~ +85℃, 10 ~ 95% RH non-condensing|
|TEMP. COEFFICIENT|±0.03% /|℃|(0~40℃)|
|VIBRATION|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|
|OPERATING ALTITUDE|Note.8|3000 meters|
|SAFETY STANDARDS|IEC60601-1, TUV BS EN/EN60601-1, ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3, EAC TP TC 004|approved|
|ISOLATION LEVEL|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP|
|WITHSTAND VOLTAGE|Note.9|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|
|ISOLATION RESISTANCE|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH|
|Parameter|Standard|Test Level / Note|
|BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22,|
|Conducted emission|CAN ICES-3(B)/NMB-3(B)|Class B|
|EMC EMISSION|Radiated emission|BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22,|Class B|
|CAN ICES-3(B)/NMB-3(B)|
|Harmonic current|BS EN/EN61000-3-2|Class A|
|SAFETY &|Voltage flicker|BS EN/EN61000-3-3|-----|
|EMC|BS EN/EN60601-1-2,|BS EN/EN61204-3|
|(Note 10)|Parameter|Standard|Test Level / Note|
|ESD|BS EN/EN61000-4-2|Level 4, 15KV air ; Level 4, 8KV contact|
|Level 3, 10V/m( 80MHz~2.7GHz )|
|RF field susceptibility|BS EN/EN61000-4-3|
|Table 9, 9~28V/m( 385MHz~5.78GHz )|
|EFT bursts|BS EN/EN61000-4-4|Level 3, 2KV|
|EMC IMMUNITY|
|Surge susceptibility|BS EN/EN61000-4-5|Level 3, 1KV/Line-Line , 2KV/Line-FG|
|Conducted susceptibility|BS EN/EN61000-4-6|Level 3, 10V|
|Magnetic field immunity|BS EN/EN61000-4-8|Level 4, 30A/m|
|100% dip 1 periods, 30% dip 25 periods,|
|Voltage dip, interruption|BS EN/EN61000-4-11|
|===|100% interruptions 250 periods|
|MTBF|2200.0K hrs min.|Telcordia SR-332 (Bellcore) ; 239.4K hrs min. MIL-HDBK-217F (25℃)|
|OTHERS|DIMENSION|175*72*35mm (L*W*H)|
|PACKING|0.66Kg; 20pcs/14.2Kg/0.95CUFT|
|——SE|
|PLUG|See page 4~5 ; Other type available by customer requested|
|CONNECTOR|
|CABLE|See page 4~5 ; Other type available by customer requested|
|℃|
**----- End of picture text -----**<br>
**NOTE**
℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft).
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
_File Name:GSM160A-SPEC 2022-11-21_
**GSM160A series**
160W AC-DC Reliable Green Medical Adaptor
**==> picture [512 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
-| Derating Curve Static Characteristics<br>100<br>100<br>90<br>80 80<br>60 70<br>50 60<br>40<br>50<br>20 40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 100 110 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br>
## ~~|~~ **Mechanical Specification**
**==> picture [179 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
35 175<br>O<br>__|<br>AC Inlet<br>IEC320-C14<br>72<br>**----- End of picture text -----**<br>
UL2464 18AWGx4C 1200±50mm Power LED 30±3mm
Case No. GS160A Unit:mm
## **DC output plug**
◎ Standard plug: R7B
|**R7B**|**Pin Assignment**|**Pin Assignment**|**Pin Assignment**|
|---|---|---|---|
|||**PIN NO.**<br>1|**OUTPUT**<br>+Vo|
|||2<br>3|-Vo<br>-Vo|
_File Name:GSM160A-SPEC 2022-11-21_
**GSM160A series**
160W AC-DC Reliable Green Medical Adaptor
- DC plug changeable through:
- (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- (2) Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:
- Optional DC plug: (Available in customized cable or quick adapter)
A B C Quick Adapter Tuning Fork Style Type No. OD ID L Accessory A C P1J 5.5 2.1 11.0 Available for 24 ~ 48V B (Current rating: 7.5A max.) (Straight) P1M 5.5 2.5 11.0 ~~Deee~~ Pin Assignment Min. DIN 4 Pin with Lock (female) Type No. PIN No. Output ~~|~~ 1 +Vo 2 3 2 -Vo 1 4 R7BF None 3 -Vo KYCON KPJX-CM-4S equivalent 4 +Vo Pin Assignment DIN 5 Pin (male) Type No. PIN No. Output ~~ee~~ 1 -Vo 1 3 2 -Vo None 4 2 5 R1B 3 +Vo 4 -Vo 5 +Vo p Pin Assignment NEUTRIK XLR NC4FX equivalent Type No. ~~rr~~ PIN No. Output 1 +Vo None 34 2 1 MIC4 32 +V-Voo ~~Qo~~ 4 -Vo Pin Assignment MOLEX 39-01-2060 (4.2mm) equivalent Type No. PIN No. Output ~~rr~~ 1 +Vo 2 +Vo ~~a. P|~~ 4 5 6 3 +Vo None 1 2 3 C6P 4 -Vo 5 -Vo FG not connected to output connector 6 -Vo
_File Name:GSM160A-SPEC 2022-11-21_
**GSM160A series**
160W AC-DC Reliable Green Medical Adaptor
**==> picture [479 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Assignment Quick Adapter<br>es AMP 1-480702-0 (6.35mm) equivalent Type No. PIN No. Output ees Accessory<br>1 +Vo<br>4<br>32 C4P 2 +Vo<br>1 None<br>3 -Vo<br>FG not connected to output connector ee 4 -Vo<br>Pin Assignment<br>Stripped and tinned leads Type No.<br>ee PIN No. Output<br>L<br>(red,blue)<br>1<br>1 +Vo<br>2<br>L1 (black,white) by customer<br>None<br>Length of Land L1 by request<br>(MW’s standard length, L: 25 mm, L1: 5 mm)<br>2 -Vo<br>( NOTE: The wire color is for reference only,<br>please refer to the actual product)<br>**----- End of picture text -----**<br>
## **Installation Manual**
Please refer to : http://www.meanwell.com/manual.html
_File Name:GSM160A-SPEC 2022-11-21_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →