Image not available
Illustrative purposes only
GMA300F-12
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 300 W, 85V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: GMA300F Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 300W
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 98.46 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC-DC Power Supplies Medical Type** ~~——~~ Medical Power World wide Safety EMI Inrush OCP OVP Remote electric Factor Approvals current ON/OFF equipment Correction limiting ## **GMA-series** ## ~~aa~~ **Feature CE marking** Wattage 300Wmax For medical electric equipment (ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.) Suitable for BF application ( Output-FG : 1MOPP, Input-Output : 2MOPP) 2"× 4" standard footprint With Remote ON/OFF (Optional) With AUX1 (12V 1A), AUX2 (5V 1A) (Optional) Low Voltage Directive RoHS Directive ## **UKCA marking** ## a Electrical Equipment Safety Regulations RoHS Regulations ## ~~a~~ **EMI** ~~a~~ **Safety agency approvals** Complies with FCC-B, CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, VCCI-B UL62368-1, ANSI/AAMI ES60601-1 C-UL (CSA62368-1, CAN/CSA60601-1) EN62368-1, EN60601-1 3rd a **EMS Compliance** : EN61204-3, EN61000-6-2 IEC60601-1-2(2014), EN60601-1-2(2015) Complies with IEC60601-1-2 4th Ed. a **5-year warranty (Refer to Instruction Manual)** EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 **GMA-1** www.cosel.co.jp/en/ December 27, 2022 **AC-DC Power Supplies Medical Type GMA300F** ~~|~~ **Ordering information** **==> picture [2 x 3] intentionally omitted <==** **----- Start of picture text -----**<br> R<br>**----- End of picture text -----**<br> **==> picture [236 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> -<br> GM A 300 F OO - O<br>1 2 3 4 5 6<br>1Series name<br>Example recommended EMI/EMC filter<br>EAC-06-472 2Single output<br>3Output wattage<br>4Universal input<br>5Output voltage<br>6Optional [*][6]<br> C : with Coating<br> J1 : Input connector<br>VH (J.S.T.) connector type<br>High voltage pulse noise type : EAP series J3 : Horizontal input connector<br>Low leakage current type : EAM series VH (J.S.T.) connector type<br>*A higher current rating EMI/EMC filter R3 : with Subfeatures<br>may be recommended in view of the other devices that could be connected in parallel with the power supply. (5V1A AUX, 12V1A AUX, Remote ON/OFF)<br>**----- End of picture text -----**<br> Specification changes when options are added. Please refer to the instruction manual for more detail. This power supply is manufactured using SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. |~~Pe~~|**MODEL**<br>~~Pe~~|**MODEL**<br>~~Pe~~|**GMA300F-12**|**GMA300F-24**|**GMA300F-48**|**GMA300F-56**| |---|---|---|---|---|---|---| |**INPUT**<br>~~Pe~~<br>~~_——————————————————————~~|**VOLTAGE[V]**<br>*3 <br>~~Pe~~<br>~~Po~~||AC85-264 1f (Output derating is required at AC85V-115V. See“Derating”)|||| ||**CURRENT[A]**<br>~~Po~~|**ACIN 115V** <br>~~Po~~|3.3typ|||| |||**ACIN 230V** <br>~~Po~~|1.8typ|||| ||**FREQUENCY[Hz]**<br>~~ee~~||50 / 60 (45-66)|||| ||**EFFICIENCY[%]**<br>~~ee~~|**ACIN 115V** <br>~~e~~<br>~~—————~~|90typ<br>~~—————~~|91typ<br>~~—————~~|91typ|91typ| |||**ACIN 230V** <br>~~e~~<br>~~—————~~|92typ<br>~~—————~~|93typ<br>~~—————~~|93typ|93typ| ||**POWER FACTOR**<br>**(Io=100%)**<br>~~ee~~<br>~~Po~~|**ACIN 115V** <br>~~e~~<br>~~—————~~<br>~~Po~~|0.95typ<br>~~—————~~|||| |||**ACIN 230V** <br>~~—————~~<br>~~Po~~|0.90typ<br>~~—————~~|||| ||**INRUSH CURRENT[A]** <br>~~Po~~|**ACIN 115V** <br>~~Po~~|30typ (Io=100%) (At cold start, Ta=25℃)|||| |||<br>**ACIN 230V** <br>~~Po~~|60typ (Io=100%) (At cold start, Ta=25℃)|||| ||**LEAKAGE CURRENT[mA]**<br>~~_——————————————————————~~||0.13 / 0.30max (ACIN 100/240V 60Hz, Io=100%, According to IEC60601-1)<br>~~_——————————————————————~~|||| |**OUTPUT**<br>~~_——————————————————————~~|**VOLTAGE[V]**<br>~~_——————————————————————~~<br>~~ee~~||12<br>~~_——————————————————————~~<br>~~ee~~|24<br>~~_——————————————————————~~<br>~~ee~~|48<br>~~_——————————————————————~~<br>~~ee~~|56<br>~~ee~~| ||**CURRENT[A]**<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~||25<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~|12.5<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~|6.3<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~|5.4<br>~~ee~~<br>~~ee~~| ||**LINE REGULATION[mV]**<br>*4 <br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~<br>~~——E——_—~~||48max<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~<br>~~E——_—~~|96max<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~|192max<br>~~_——————————————————————~~<br>~~ee~~<br>~~ee~~|192max<br>~~ee~~<br>~~ee~~| ||**LOAD REGULATION[mV]**<br>*4 <br>~~ee~~<br>~~ee~~<br>~~——E——_—~~||100max<br>~~ee~~<br>~~ee~~<br>~~E——_—~~|150max<br>~~ee~~<br>~~ee~~|240max<br>~~ee~~<br>~~ee~~|240max<br>~~ee~~<br>~~ee~~| ||**RIPPLE[mVp-p]**<br>*1<br>~~ee~~<br>~~——E——_—~~|**0 to +50**C <br>~~ee~~<br>~~E——_—~~|240max<br>~~ee~~<br>~~E——_—~~|240max<br>~~ee~~|400max<br>~~ee~~|400max<br>~~ee~~| |||**-20 to 0**C <br>~~E——_—~~|320max<br>~~E——_—~~|320max|500max|500max| ||**RIPPLE NOISE[mVp-p]***1<br>~~——E——_—~~<br>~~a~~<br>~~——E—————~~|**0 to +50**C <br>~~E——_—~~<br>~~——E—————~~|300max<br>~~E——_—~~<br>~~——E—————~~|300max<br>~~——E—————~~|500max|500max| |||**-20 to 0**C <br>~~——E—————~~|360max<br>~~——E—————~~|360max<br>~~——E—————~~|580max|580max| ||**TEMPERATURE REGULATION[mV]**<br>~~——E—————~~|**0 to +50**C <br>~~——E—————~~|120max<br>~~——E—————~~|240max<br>~~——E—————~~|480max|480max| |||**-20 to +50**C <br>~~——E—————~~<br>~~a~~|150max<br>~~——E—————~~<br>~~C~~|290max<br>~~——E—————~~<br>~~C~~|600max<br>~~C~~|600max| ||**DRIFT[mV]**<br>*2 <br>~~——E—————~~<br>~~eG~~||48max<br>~~——E—————~~<br>~~eG~~|96max<br>~~——E—————~~<br>~~OG~~|192max<br>~~OG~~|192max| ||**START-UP TIME[ms]**<br>~~Po~~||400typ (ACIN 115V, Io=100%)<br>*Start-up time is 900ms typ for less than 1minute of applying input again from turning off the input voltage.|||| ||**HOLD-UP TIME[ms]**||16typ (ACIN 115V, Io=85%) / 12typ (ACIN 115V, Io=100%)|||| ||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~GC~~<br>~~a~~||11.40 ~13.20<br>~~GC~~<br>~~Ge~~|22.80 ~26.40<br>~~GC~~|45.60 ~52.80<br>~~GC~~|52.00 ~56.00| ||**OUTPUT VOLTAGE SETTING[V]**<br>~~a~~||12.00 ~12.48<br>~~Ge~~|24.00 ~24.96|48.00 ~49.92|55.00 ~56.00| |**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~a~~<br>~~Jo~~||Works over 105% of rating and recovers automatically<br>~~Ge~~|||| ||**OVERVOLTAGE PROTECTION[V]**<br>~~a~~||13.80 to 16.80|27.60 to 33.60|55.20 to 67.20<br>~~G~~|60.00 to 70.50| ||**AUX1 (12V1A)**<br>~~Jo~~||Optional|||| ||**AUX2 (5V1A)**<br>~~Po~~||Optional|||| ||**REMOTE ON/OFF**<br>~~Po~~||Optional|||| |**ISOLATION**|**INPUT-OUTPUT**-**RC**-**AUX** *7 <br>~~Po~~||AC4,000V 1minute, Cutoff current=10mA, DC500V 50MWmin (At Room Temperature) 2MOPP|||| ||**INPUT-FG**<br>~~Po~~||AC2,000V 1minute, Cutoff current=10mA, DC500V 50MWmin (At Room Temperature) 1MOPP|||| ||**OUTPUT**-**RC**-**AUX-FG**<br>*7 <br>~~Jo~~||AC1,500V 1minute, Cutoff current=10mA, DC500V 50MWmin (At Room Temperature) 1MOPP|||| ||**OUTPUT-RC**-**AUX**<br>*7 <br>~~Po~~||AC100V 1minute, Cutoff current=25mA, DC100V 10MWmin (At Room Temperature)|||| |**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE**<br>~~po~~||-20 to +70C, 20-90%RH (Non condensing), 5,000m (16,000feet) max*3*8|||| ||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-30 to +75C, 20-90%RH (Non condensing), 9,000m (30,000feet) max|||| ||**VIBRATION**<br>~~Po~~||10-55Hz, 19.6m/s2(2G), 3minutes period, 60minutes each along X, Y and Z axis|||| ||**IMPACT**<br>~~Pe~~||196.1m/s2(20G), 11ms, once each X, Y and Z axis|||| |**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**<br>~~|~~|**AGENCY APPROVALS**<br>~~po~~<br>~~|~~||UL62368-1, ANSI/AAMI ES60601-1, C-UL, EN62368-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed.|||| ||**CONDUCTED NOISE**<br>~~|~~||Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B|||| ||**HARMONIC ATTENUATOR** *5 <br>~~|Po~~||Complies with IEC61000-3-2 (class A)|||| |**OTHERS**|**CASE SIZE/WEIGHT**<br>~~po~~||50.8×37×101.6mm [2.0×1.5×4.0 inches] (W×H×D) / 230g max|||| ||**COOLING METHOD**<br>~~PT~~||Forced air (Requires external fan)|||| - *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). - *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25℃ , with the input voltage held constant at the rated input/output. - *3 Refer to “ Derating ” - *4 Please contact us about dynamic load and input response. *6 - *7 Applicable when AUX and remote control (optional) is added. - *8 Please contact us about for more detail. - - Parallel operation is not possible. - Sound noise may be generated by power supply in case of pulse load. - Substrate bottom has a Electric potential. Insulation is required. - *5 Please contact us about another class. **GMA-2** www.cosel.co.jp/en/ December 27, 2022 **GMA300F** ## **Features** - **High power density : 25.7W/inch[3]** - **High efficiency : 93% typ (Input Voltage 230V, Output Voltage 24V)** - **For medical electric equipment (ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)** - **Suitable for BF application (Output-FG : 1MOPP, Input-Output : 2MOPP)** - **2"× 4"standard footprint** - **With Remote ON/OFF (Optional)** - **With AUX1 (12V 1A), AUX2 (5V 1A) (Optional)** ## **Block diagram** **==> picture [314 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> AC85 - 264V FUSE250V6.3A ×2 FILTERNOISE CURRENTINRUSHLIMIT RECTIFIER INDUCTORBOOSTER CURRENTSENSING RECTIFIERFILTERAND<br>FG INVERTER<br>CONTROL<br>TRANSFORMER<br>RECTIFIER<br>INVERTER AND AUX1 (12V 1A) Optional<br>FILTER<br>RECTIFIER<br>CURRENTSENSING FILTERAND DC OUT<br>REGULATORINTERNAL CONTROL<br>Photocoupler OVER<br>VOLTAGE<br>PROTECTION<br>Photocoupler<br>CONTROL<br>RC (REMOTE ON/OFF) Optional<br>TRANSFORMER<br>RECTIFIER<br>AND AUX2 (5V 1A) Optional<br>FILTER<br>**----- End of picture text -----**<br> ## **External view** - External size of option J3 is different from standard model and refer to 6 Option and Others of instruction manual for details. **==> picture [248 x 225] intentionally omitted <==** **----- Start of picture text -----**<br> 3.2 [[0.13]] 95.3±0.5 [[3.75]]<br>CN701(Optional)<br>Name plate 4-f3.4<br>Mounting Holes<br>output(+)<br>FG TB501<br>AC(N)<br>CN101<br>AC(L)<br>output(-)<br>TB502<br>86.8 [[3.42]] Voltage adjust<br>95.7 [[3.77]] CN601(Optional)<br>101.6 [[4.00]]<br>3.5max<br>[0.14]<br>[1.75]<br>[2.00] 0.5<br>50.8 44.5± 7.6 [0.30] 16.2 [0.64]<br>14.4 [0.57]<br>[1.31]<br>33.2<br>15.8 [0.62]<br>**----- End of picture text -----**<br> - Tolerance ±1 [±0.04] - Weight : 230g max - There is a total of four attachment holes. - Dimensions in mm, [ ]=inches - Screw tightening torque : (TB501, 502) : 1.25N-m max - Mounting toque : 0.6N-m max - Avoid contact between TB501 and 502 wiring with mounting parts. **==> picture [214 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> I/O Connector Mating Terminal Mfr<br>connector<br>Standard CN101 1-1123724-2 1-1123722-3 1123721-1 Tyco<br>CN101 1318912-1 Electronics<br>R3 CN601 B8B-PHDSS PHDR-08VS SPHD-002T-P0.5<br>CN701 B2B-PH PHR-2 SPH-002T-P0.5S<br>J1 CN101<br>B2P3-VH VHR-3N SVH-21T-P1.1 J.S.T.<br>CN101<br>J1R3 CN601 B8B-PHDSS PHDR-08VS SPHD-002T-P0.5<br>CN701 B2B-PH PHR-2 SPH-002T-P0.5S<br>FG Mating connector Terminal Mfr<br>250 (62409-1) - 170603-2 Tyco Electronics<br>**----- End of picture text -----**<br> ## <Pin Assignments> ## <CN101> |||Pin No.<br>1|Input<br>AC(L)||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||2|||||||||||| |||3|AC(N)||||||||||| ||<CN601(Optional)>||||||||||||| |||Pin No.<br>1<br>2<br>3|Function<br>RC<br>: REMOTE ON/OFF<br>RCG<br>: REMOTE ON/OFF(GND)<br>N.C.<br>: No connection|||2||||||1|| |||4<br>5|N.C.<br>: No connection<br>N.C.<br>: No connection|||8||||||7|| |||6|N.C.<br>: No connection|CN601|||||||||| |||7|AUX2 : AUX2(5V 1A)||||||||||| |||8|AUX2G : AUX2(GND)||||||||||| ||<CN701(Optional)>||||||||||||1| |||Pin No.|Function||||||||||2| |||1|AUX1G : AUX1(GND)||||||||||| |||2|AUX1 : AUX1(12V 1A)|CN701|||||||||| **GMA-3** www.cosel.co.jp/en/ December 27, 2022 ## **GMA-series** ## **Assembling and Installation Method** **==> picture [225 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> ¡ Mounting method<br>(A) (B) (C)<br>CN101<br>CN101<br>CN101<br>Standard Position<br>**----- End of picture text -----**<br> - ¡ AC voltage exists on the primary side. Therefore, in order to prevent electric shock, or to meet the leakage current requirements of the safety standard, you need to ensure the proper insulation distance. Therefore, in order to prevent electric shock, or to meet the leakage current requirements of the safety standard, you need to ensure the proper insulation distance. - ¡ In case of metal chassis, keep the distance shown as right figure between component and metal chassis for insulation, use the spacer of 8mm or more between bottom of power supply and metalchassis. If it is less than reqired distance, insert the insulation sheet between power supply and metal chassis. The following distance is not satisfactory for cooling condition. - Please refer to “Derating”. **==> picture [215 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> (D) (E) (F)<br>CN101<br>CN101<br>CN101<br>5mm min<br>CN101<br>Component side<br>8mm min<br>d1<br>d1 d1<br>d1<br>d1=4mm min<br>**----- End of picture text -----**<br> ## **Mounting screw** - ¡ The mounting screw should be M3. The hatched area shows the allowance of metal parts for mounting. - ¡ If metallic fittings are used on the component side of the board, ensure there is no contact with surface mounted components. - ¡ This product uses SMD technology. - Please avoid the PCB installation method which includes the twist- - ing stress or the bending stress. **==> picture [196 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> 7 7<br>7 7<br>CN101<br>7 7<br>7 7 Unit [mm]<br>**----- End of picture text -----**<br> ## **Derating** ## ¡ Cooling method Conduction cooling are available.Please see instruction manual 3 for details.Please make sure the maximum component temperature rise given in instruction manual 3 is not exceeded. ## ¿ Derating curve for input voltage **==> picture [195 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>0<br>85 100 115<br>Input voltage [V]<br>Load factor [%]<br>**----- End of picture text -----**<br> **GMA-4** www.cosel.co.jp/en/ December 27, 2022 ## **GMA-series** ## **Derating** ## ¿ Ambient temperature derating curve at forced air (Reference value) **==> picture [205 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> ( * 1)) (A) - (F) mounting<br>100 a e eee<br>AA eee<br>50<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br> **==> picture [209 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> * 1 The maximum output power by wind speed conditions<br>(Reference value)<br>350<br>300<br>250<br>200<br>150<br>0<br>0 1.0 1.5 2.0 2.5 3.0 3.5<br>Wind velocity [m/s]<br>Output power [W]<br>**----- End of picture text -----**<br> ¡ Specifications for ripple and ripple noise changes in the shaded area. - ¡ Please see instruction manual 3 for recommended cooling condition. ## **Instruction Manual** ◆ It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product. Instruction Manual https://www.cosel.co.jp/redirect/catalog/en/GMA/ Before using our product https://en.cosel.co.jp/technical/caution/index.html **==> picture [84 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> GMA NOTICE<br>**----- End of picture text -----**<br> ## **Basic Characteristics Data** |Model|Circuit method|Switching<br>frequency<br>[kHz]|Input<br>current<br> *1 [A]|Inrush<br>current<br>protection|PCB/Pattern|PCB/Pattern|PCB/Pattern|Series/Parallel<br>operation availability|Series/Parallel<br>operation availability| |---|---|---|---|---|---|---|---|---|---| ||||||Material|Single<br>sided|Double<br>sided|Series<br>operation|Parallel<br>operation| |GMA300F|Active filter|40 - 120|3.3|Thermistor|FR-4|-|Yes|Yes|No| ||LLC resonant converters|90 - 180|||||||| *1 The value of input current is at ACIN 115V and rated load. **GMA-5** www.cosel.co.jp/en/ December 27, 2022
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →