GCS350PS28
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 350W @ 15CFM, 200 W
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):200W; Power Rating (Forced Cooling):350W @ 15CFM; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Adjustable,
- SVHC: No SVHC (15-Jan-2018)
- Product Range: GCS350 Series
- No. of Outputs: 1 Output
- Output Power Max: 350W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 28VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): 350W @ 15CFM
- Power Rating (Convection Cooling): 200W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 113.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
**GCS Series AC-DC Power Supplies** a a:
> **AC-DC Power Supplies** XP Power
## 150/180/250/350 Watts
- Convection/Forced-cooled Ratings
- Universal 85 - 264 VAC Input
- IT & Medical Safety Approvals (Class I & II)
- < 0.5 W Standby Power (150 & 180 Models)
- -40° C to +70° C Operation
- Remote On/Off
- Class B Emissions
- 3 Year Warranty
The GCS Series has been designed to minimise the no load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. Approved for Class I and Class II applications, this range of single output AC-DC power supplies are packaged in an industry standard 3.0" x 5.0" x 1.42" package and achieves EN55011/32 Level B emissions compliance whilst maintaining very low earth leakage currents, making them suitable for a wide range of 1U and other industrial, IT and medical applications.
Dimensions:
GCS150/GCS180/GCS250/GCS350: 5.00 x 3.00 x 1.42” (127.0 x 76.2 x 36.3 mm) (-C): 5.50 x 3.48 x 1.70” (139.7 x 88.5 x 43.2 mm) (-TF): 5.50 x 3.48 x 2.20” (139.7 x 88.5 x 57.8 mm) (-EF): 6.35 x 3.48 x 1.70” (161.3 x 88.5 x 43.2 mm) (350-EF): 6.00 x 3.50 x 1.75” (152.4 x 88.9 x 44.4 mm)
The series has single output versions from 12 V to 56 VDC, dual-fusing for compliance with IEC60601-1 and feature minimal excess heat generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 °C and up to +70 °C and are available with a number of cover options.
## Models & Ratings
|Output Voltage V1|Output Current V1|Output Current V1|Output Voltage (Vfan)<br>& Current|Max Output Power|Model Number(1,2,3,4,5)|
|---|---|---|---|---|---|
||Convection-cooled(6,7)|Forced-cooled(8)||||
|12.0 VDC|9.2 A|12.5 A|12.0 VDC/0.6 A|157 W|GCS150PS12|
|15.0 VDC|7.3 A|10.0 A|12.0 VDC/0.6 A|157 W|GCS150PS15|
|24.0 VDC|4.6 A|6.3 A|12.0 VDC/0.6 A|157 W|GCS150PS24|
|28.0 VDC|3.9 A|5.4 A|12.0 VDC/0.6 A|157 W|GCS150PS28|
|48.0 VDC|2.3 A|3.2 A|12.0 VDC/0.6 A|157 W|GCS150PS48|
|12.0 VDC|12.5 A|15.0 A|12.0 VDC/0.6 A|187 W|GCS180PS12|
|15.0 VDC|10.0 A|12.0 A|12.0 VDC/0.6 A|187 W|GCS180PS15|
|24.0 VDC|6.3 A|7.5 A|12.0 VDC/0.6 A|187 W|GCS180PS24|
|28.0 VDC|5.4 A|6.4 A|12.0 VDC/0.6 A|187 W|GCS180PS28|
|48.0 VDC|3.1 A|3.7 A|12.0 VDC/0.6 A|187 W|GCS180PS48|
|12.0 VDC|15.0 A|18.8 A|12.0 VDC/0.6 A|232 W|GCS250PS12|
|15.0 VDC|12.0 A|15.0 A|12.0 VDC/0.6 A|232 W|GCS250PS15|
|24.0 VDC|7.5 A|10.4 A|12.0 VDC/0.6 A|257 W|GCS250PS24|
|28.0 VDC|6.4 A|8.9 A|12.0 VDC/0.6 A|257 W|GCS250PS28|
|48.0 VDC|3.7 A|5.2 A|12.0 VDC/0.6 A|257 W|GCS250PS48|
|56.0 VDC|3.2 A|4.5 A|12.0 VDC/0.6 A|257 W|GCS250PS56|
|12.0 VDC|16.7 A|29.2 A|12.0 VDC/0.6 A|350 W|GCS350PS12(9)|
|15.0 VDC|13.3 A|23.4 A|12.0 VDC/0.6 A|350 W|GCS350PS15(9)|
|24.0 VDC|8.3 A|14.6 A|12.0 VDC/0.6 A|350 W|GCS350PS24(10)|
|28.0 VDC|7.1 A|12.5 A|12.0 VDC/0.6 A|350 W|GCS350PS28(10)|
|48.0 VDC|4.2 A|7.3 A|12.0 VDC/0.6 A|350 W|GCS350PS48(10)|
|56.0 VDC|3.6 A|6.25 A|12.0 VDC/0.6 A|350 W|GCS350PS56(10)|
## ~~**Notes**~~
_1. Add suffix -C for convection-cooled cover, e.g. GCS150PS12-C._
_2. Cover kits available. Order part no.: GCS150/180 CVR KIT_
_3. Add suffix -EF for fan-cooled cover with end fan e.g. GCS150PS12-EF, add suffix -TF for fan-cooled cover with top fan, e.g. GCS150PS12-TF. Note: Vfan output no longer available._
_4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers, (remote on/off is standard on GCS350 models)._
_5. GCS250PS12-C & GCS250PS15-C models derate 20% when convection cooled._
_6. GCS350 convection rating quoted at 40 °C, others at 50 °C, see thermal derating curve._
_7. GCS350-C models derate 15% when convection-cooled at 40 °C._
_8. 7 CFM required to meet stated current for GCS150/180/250 and 15 CFM for GCS350._
_9. Add suffix ‘-J’ for optional dual row molex connector. See GCS350 model mechanics for details._
_10. Add suffix ‘-S’ for optional screw terminals. See GCS350 mechanics for details._
**www.xppower.com**
1
XP Power
**==> picture [539 x 627] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic Minimum Typical Maximum Units Notes & Conditions<br>Input Voltage - Operating 85 115/230 264 VAC Derate output power <90 VAC. See fig 1.<br>Input Frequency 47 50/60 63 Hz<br>Power Factor >0.9 230 VAC, 100% load<br>1.5/0.7 GCS150: 115/230 VAC<br>1.8/0.8 GCS180: 115/230 VAC<br>Input Current - Full Load 2.2/1.1 A GCS250 12-15 V models: 115/230 VAC<br>2.4/1.2 GCS250 ≥ 24 V models: 115/230 VAC<br>3.6/1.8 GCS350: 115/230 VAC<br>Inrush Current 80 A 230 VAC cold start 25 °C<br>0.5 All GCS150 & GCS180 (including -R Models)<br>2.3 GCS150 & GCS180 -R Models with inhibit activated<br>5 All GCS250 (including -R Models) 115V AC<br>No Load Input Power 3 W All GCS250 (including -R Models) 230V AC<br>1 GCS250 -R Models with inhibit activated 115V AC<br>3 GCS250 -R Models with inhibit activated 230V AC<br>4 GCS350: 115/230 VAC<br>60/120 200 GCS150: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max.<br>95/185 250 GCS180: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max.<br>Earth Leakage Current 95/185 250 μ A GCS250: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max.<br>95/185 250 GCS350: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max.<br>Input Protection GCS150/180: F3.15 A/250 V internal fuse in both lines. GCS250/350: F5.0 A/250 V internal fuse in both lines.<br>Input Voltage Derating Curve<br>Figure 1 180 250<br>170 GCS180PSxx forced-cooled 240 Forced-cooled (24 V / 28 V / 48 V)<br>160 230<br>150 220<br>GCS180PSxx convection-cooled<br>140 GCS150PSxx forced-cooled 210 Forced-cooled (12 V / 15 V)<br>130 200<br>120 190<br>110 180<br>100 GCS150PSxx convection-cooled 170 Convection-cooled (All models)<br>90 160<br>— 0 — 0<br>85 90 100 220 230 240 250 260 264 270 85 90 100 220 230 240 250 260 264 270<br>Input Voltage (VAC) Input Voltage (VAC)<br>GCS150 & GCS180 GCS250<br>360<br>340 Forced-cooled<br>320<br>300<br>280<br>260<br>240<br>220<br>200<br>Convection-cooled (at 40 °C)<br>180<br>160 Convection-cooled (at 50 °C)<br>0 =<br>85 90 100 220 230 240 250 260 264 270<br>Input Voltage (VAC)<br>GCS350<br>Output Power (W) Output Power (W)<br>Output Power (W)<br>**----- End of picture text -----**<br>
**www.xppower.com**
2
**GCS Series AC-DC Power Supplies** e ~~e~~
XP Power
Output
|Characteristic<br>~~DC~~|Minimum<br>~~DC~~|Typical<br>~~DC~~|Maximum<br>~~DC~~|Units<br>~~DC~~|Notes & Conditions<br>~~DC~~|
|---|---|---|---|---|---|
|Output Voltage - V1<br>~~Ge~~<br>~~Re~~|12<br>~~Ge~~<br>~~Ge~~|~~GGG~~<br>~~GG~~|56<br>~~GGG~~<br>~~GG~~|VDC<br>~~GGG~~<br>~~GG~~|See Models and Ratings table<br>~~GGG~~|
|Initial Set Accuracy<br>~~Re~~|~~Ge~~|~~GG~~<br>~~CO~~|±1(V1)& ±5(Vfan)<br>~~GG~~<br>~~CO~~|%<br>~~GG~~<br>~~CO~~|50% load,115/230 VAC|
|Output Voltage Adjustment -V1<br>~~Re~~<br>~~eG~~|~~Ge~~<br>~~eG~~|~~GG~~<br>~~eG~~<br>~~CO~~<br>~~Ge~~|±2<br>~~GG~~<br>~~eG~~<br>~~CO~~<br>~~Ge~~|%<br>~~GG~~<br>~~eG~~<br>~~CO~~<br>~~GO~~|Viapotentiometer. See mech. details,Vfan will track<br>~~eG~~<br>~~GO~~|
|Minimum Load<br>~~eG~~<br>~~Ge~~|0<br>~~eG~~<br>~~Ge~~|~~eG~~<br>~~CO~~<br>~~Ge~~<br>~~Ge~~|~~eG~~<br>~~CO~~<br>~~Ge~~<br>~~Ge~~|A<br>~~eG~~<br>~~CO~~<br>~~Ge~~<br>~~GO~~|~~eG~~<br>~~Ge~~<br>~~GO~~|
|Start UpDelay|~~ae~~|~~Ge~~<br>~~ee~~|2<br>~~Ge ~~|s<br> ~~GO~~|115/230 VAC full load<br>~~GO~~<br>~~PT~~|
|Hold Up Time|~~ae~~|20<br>~~ee~~||ms<br>~~GG~~|GCS150Models<br>~~PT~~|
||~~ae~~<br>~~a~~<br>~~ee~~|16/18<br>~~ee~~<br>~~ee~~|||GCS180 Models<br>~~PT~~<br>~~PO~~<br>~~Pe~~|
||~~a~~<br>~~ee~~<br>~~es~~|25<br>~~ee~~|||GCS250PS12(225W)<br>~~PO~~<br>~~Pe~~<br>~~PT~~|
||~~ee~~<br>~~es~~<br>~~ee~~|17<br>~~ee~~|||GCS250 Other Models(250W)<br>~~Pe~~<br>~~PT~~<br>~~PO~~|
||~~es~~<br>~~ee~~|17<br>~~GG~~|~~GG~~||GCS350<br>~~PT~~<br>~~PO~~|
|Drift<br>~~eG~~|~~ee~~<br>~~eG~~|~~eG~~<br>~~GG~~|±0.2<br>~~eG~~<br>~~GG~~|%<br>~~eG~~<br>~~GG~~|After 20 min warm up<br>~~PO~~<br>~~eG~~|
|Line Regulation<br>~~GC~~|~~GC~~|~~GG~~<br>~~GC~~|±0.5<br>~~GG~~<br>~~GC ~~|%<br>~~GG~~<br> ~~GG~~|90-264 VAC<br>~~GG~~|
|Load Regulation<br>~~Ge~~|~~Ge~~|~~COG~~<br>~~OQ~~|±0.5(V1),±5(Vfan)<br>~~COG~~<br>~~OQ~~|%<br>~~COG~~<br>~~OQ~~|0-100% load<br>~~COG~~|
|Transient Response - V1<br>~~Ge~~<br>~~ee~~<br>~~Re~~|~~Ge~~<br>~~ee~~<br>|~~COG~~<br>~~ee~~<br>~~OQ~~<br>~~**G**~~|4<br>~~COG~~<br>~~ee~~<br>~~OQ~~<br>~~**G**O~~|%<br>~~COG~~<br>~~ee~~<br>~~OQ~~<br>~~O~~|Recovery within 1% in less than 500μs<br>for a 50-75% and 75-50% load step<br>~~COG~~<br>~~ee~~|
|Over/Undershoot - V1<br>~~eG~~<br>~~Re~~|~~eG~~<br>~~Ge~~|0<br>~~OQ~~<br>~~eG~~<br>~~**G**~~|~~OQ~~<br>~~eG~~<br>~~**G**O~~<br>~~G~~|%<br>~~OQ~~<br>~~eG~~<br>~~O~~<br>~~G~~|~~eG~~|
|Ripple & Noise - V1<br>~~Re~~<br>~~Rs~~|~~Ge~~<br>|~~**G**~~<br>~~CO~~<br>|1<br>~~**G**O~~<br>~~G~~<br>~~CO~~<br>|%pk-pk<br>~~O~~<br>~~G~~<br>~~CO~~<br>|20 MHz bandwidth,12V Models 1.5% max<br>|
|Overvoltage Protection - V1<br>~~Re~~<br>~~Ge~~<br>~~Rs~~|110<br>~~Ge~~<br>~~Ge~~<br>~~Ge GO~~|~~**G**~~<br>~~Ge~~<br>~~CO~~<br>~~GO~~|140<br>~~**G**O~~<br>~~G~~<br>~~Ge~~<br>~~CO~~<br>~~GO~~|%<br>~~O~~<br>~~G~~<br>~~Ge~~<br>~~CO~~<br>~~GO~~|Vnom DC. Output 1,recycle input to reset<br>~~Ge~~<br>~~GO~~|
|Overload Protection - V1<br>~~Rs~~|110<br>~~Ge GO~~|~~CO~~<br>~~GO~~<br>~~CO~~|150<br>~~CO~~<br>~~GO~~<br>~~CO~~|% I nom<br>~~CO~~<br>~~GO~~<br>~~CO~~|See fig. 2. Trip and Restart<br>~~GO~~|
|Short Circuit Protection - V1<br>~~Rs~~<br>~~Ge~~<br>~~ee~~|~~Ge GO~~<br>~~Ge~~<br>|~~CO~~<br>~~GO~~<br>~~Ge~~<br>~~CO~~<br>~~GG~~|~~CO~~<br>~~GO~~<br>~~Ge~~<br>~~CO~~<br>~~GG~~|~~CO~~<br>~~GO~~<br>~~Ge~~<br>~~CO~~<br>~~GG~~|Continuous<br>~~GO~~<br>~~Ge~~|
|Temperature Coefficient<br>~~eG~~<br>~~ee es~~|~~eG~~<br>~~es~~|~~CO~~<br>~~eG~~<br>~~GG~~<br>es|0.05<br>~~CO~~<br>~~eG~~<br>~~GG~~|%/˚C<br>~~CO~~<br>~~eG~~<br>~~GG~~|~~eG~~|
|Overtemperature Protection<br>~~ee es~~|~~es~~|~~GG~~<br>es|110<br>~~GG~~|°C<br>~~GG~~|At measurement point. Present on GCS350 only.<br>Measurement internally, auto resetting.|
## **Output Overload Characteristic**
Figure 2 GCS180PS12 example (other similar).
**==> picture [273 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
12<br>10<br>8<br>6 Trip & Restart<br>4<br>2<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24<br>Output Load (A)<br>Output Voltage (V)<br>**----- End of picture text -----**<br>
**www.xppower.com**
3
**GCS Series**
XP Power
**AC-DC Power Supplies**
## General
|Characteristic<br>~~CG~~|Minimum<br>~~G~~|Typical<br>~~G~~|Maximum<br>~~GGG~~|Units<br>~~GGG~~|Notes & Conditions<br>~~GGG~~|
|---|---|---|---|---|---|
|Efficiency<br>~~CG~~|~~G~~<br>~~aa~~|93<br>~~G ~~<br>~~aa~~|~~GGG~~<br>~~aa~~|%<br>~~GGG~~|230 VAC Full load (see fig.3-5 )<br>~~GGG~~|
||80 Plus Silver<br>~~a~~|~~a~~|||All models except 12 V models|
||80 Plus Bronze<br>~~a~~|~~a~~|||12 V models|
|Isolation: Input to Output<br>Input to Ground<br>Output to Ground<br>~~a~~<br>~~rr~~|4000<br>~~a~~|~~a~~||VAC||
||1500<br>~~a~~<br>~~ee~~<br>~~a~~|~~a~~<br>~~ee~~||VAC|~~PO~~|
||1500<br>~~a~~<br>~~es~~|~~eS~~|~~eS ae~~|VAC<br>~~ae~~|~~PO~~<br>~~Po~~|
|Switching Frequency<br>~~a~~<br>~~rr~~|60<br>~~a~~<br>~~es~~|~~eS~~|200<br>~~eS ae~~|kHz<br>~~ae~~|PFC Converter<br>~~PO~~<br>~~Po~~|
||90<br>~~a~~<br>~~es~~|~~eS~~|150<br>~~eS ae~~||Main Converter<br>~~PO~~<br>~~Po~~|
|Power Density<br>~~a~~<br>~~rr~~|~~a~~<br>~~es~~<br>~~ee~~|~~eS~~<br>~~ee~~|7.4<br>~~eS ae~~<br>~~ee~~|W/in3<br>~~ae~~|GCS150<br>~~PO~~<br>~~Po~~<br>~~pO~~|
||~~es~~<br>~~ee~~<br>~~ee~~|~~eS~~<br>~~ee~~|8.8<br>~~eS ae~~<br>~~ee~~||GCS180<br>~~Po~~<br>~~pO~~<br>~~PO~~|
||~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~|12.1<br>~~ee~~||GCS250<br>~~pO~~<br>~~PO~~<br>~~pO~~|
||~~ee~~<br>~~ee~~||16.4||GCS350<br>~~PO~~<br>~~pO~~|
|Mean Time Between Failure<br>~~pf~~|~~ee~~<br>~~pf~~|569<br>~~pf~~|~~pf~~|kHrs<br>~~pf~~|MIL-HDBK-217F, Notice 2 +25 °C GB<br>~~pO~~<br>~~pf~~|
|Weight: Open Frame<br>End Fan Unit<br>Top Fan Unit<br>Covered Unit|~~a~~|0.65 (0.29)||lb (kg)||
||~~a~~|1.30 (0.59)||lb (kg)||
||~~a~~|1.15 (0.52)||lb (kg)||
||~~a —~~|1.05 (0.48)<br>~~—~~|~~—~~|lb (kg)<br>~~—~~|~~—~~|
**==> picture [412 x 415] intentionally omitted <==**
**----- Start of picture text -----**<br>
Efficiency Vs Load 100.00%<br>90.00%<br>Figure 3 80.00%<br>12 V Models 70.00% PO<br>60.00%<br>50.00%<br>115V<br>40.00%<br>230V<br>30.00%20.00% PO<br>10.00%<br> — 0.00%<br>20% 25% 50% 67% 75% 100%<br>Load %<br>Figure 4 100.00%<br>24 V Models 90.00%<br>80.00%<br>70.00%<br>60.00%<br>50.00%<br>115V<br>40.00%<br>230V<br>30.00%<br>20.00%<br>10.00%<br>0.00%<br>20% 25% 50% 67% 75% 100%<br>Load %<br>Figure 5 100.00%<br>48 V Models 90.00%<br>80.00%<br>70.00%<br>60.00%<br>50.00%<br>115V<br>40.00%<br>230V<br>30.00%<br>20.00%<br>10.00%<br>0.00% —<br>20% 25% 50% 67% 75% 100%<br>Load %<br>Efficiency (%)<br>Efficiency (%)<br>Efficiency (%)<br>**----- End of picture text -----**<br>
**www.xppower.com**
4
**GCS Series AC-DC Power Supplies**
XP Power
Signals & Controls Characteristic Notes & Conditions Remote Sense Compensates for 0.5 V total voltage drop Inhibit The inhibit lo (pin 4), should be pulled below 0.4 V to switch V1 & Vfan off. Open circuit or >4 V to switch on (see fig. 6) Remote On/Off (-R models) (Standard on GCS350 models) Enable With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4) will enable V1 & V fan output. (see fig. 7) ~~—~~
**Remote On/Off (Inhibit)** Figure 6
|**Remote On/Off (Inhibit)**||||**Remote On/Off (Enable)**|**Remote On/Off (Enable)**||
|---|---|---|---|---|---|---|
|Figure 6||||Figure 7|||
|0 V<br>Inhibit Lo<br>Pin 4<br>~~f~~p|POWER SUPPLY|||0 V<br>Inhibit Lo<br>Pin 4<br>Inhibit Hi<br>Pin 5<br>~~O~~F||POWER SUPPLY|
|Signals Connector|Signals Connector||||Signals Connector|Signals Connector|
|Environmental|||||||
|Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions||
|OperatingTemperature|-40||+70|°C|See deratingcurve, fig. 8||
|Storage Temperature|-40||+85|°C|||
||||||Forced Cooled >110 W GCS150|Forced Cooled >110 W GCS150|
|Cooling|7|||CFM|Forced Cooled >150 W GCS180<br>Forced Cooled >180 W GCS250||
||15||||GCS350||
|Humidity|5||95|%RH|Non-condensing||
|OperatingAltitude|||5000|m|||
|Shock|||||±3 x 30g shocks in each plane, total 18 shocks. 30g =<br>11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27<br>& EN60068-2-47<br>|||
|Vibration|||||Single axis 10 - 500 Hz at 2g sweep and endurance at<br>resonance in all 3 planes. Conforms to EN60068-2-6||
## **Thermal Derating Curve**
Figure 9 - GCS350 Convection cooled ratings
Figure 10 - GCS350 Forced cooled ratings
**==> picture [541 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 8 - GCS150, 180, 250<br>100 350 350<br>300 300<br>250 250<br>Open Frame<br>225 225 Forced Cooled<br>200 200<br>With Cover<br>50 175 175<br>170 150<br>130 100<br>87 87<br>65 50<br>0 - 0 0<br>-40 -20 0 50 70 -40 -30 -20 -10 0 10 20 30 40 50 60 70 -40 -30 -20 -10 0 10 20 30 40 50 60 70<br>Ambient Temperature (ºC) Ambient Temperature (ºC) Ambient Temperature (ºC)<br>Output Load (%) Some specification Output Load (W) Some specification Output Load (W) Some specification<br>parameters may not be met parameters may not be met parameters may not be met<br>**----- End of picture text -----**<br>
**www.xppower.com**
5
**GCS Series**
XP Power
**AC-DC Power Supplies**
## EMC: Emissions
|Phenomenon|Standard|Test Level|Criteria|Notes & Conditions|
|---|---|---|---|---|
|Conducted|EN55011/32|Class B|||
|Radiated|EN55011/32|Class B||GCS150|
|||Class A||GCS180/GCS250/GCS350|
|||Class B||GCS180 & GCS250 with 3 turns of output cable<br>through added ferrite core. (Manufacturer:<br>Fair - Rite Products Corp, Part No: 2643800502)|
|Harmonic Fluctuations|EN61000-3-3||||
## EMC: Immunity
||Phenomenon|Standard|Test Level|Criteria|Notes & Conditions|
|---|---|---|---|---|---|
||Low Voltage PSU EMC|EN61204-3|High severity level|as below||
||||Class A||All models|
||||||> 50 W GCS150|
||Harmonic Current|EN61000-3-2|Class C||> 50 W GCS180|
||||||> 80 W GCS250|
||||||>125 W GCS350|
||Radiated|EN61000-4-3|3|A||
||EFT|EN61000-4-4|3|A||
||Surges|EN61000-4-5|Installation class 3|A||
||Conducted|EN61000-4-6|3|A||
||||Dip >95% (0 VAC), 8.3ms|A||
|||EN55035<br>(100 VAC)|Dip 30% (70 VAC), 416ms|B||
||||Dip >95% (0 VAC), 4160ms|B||
||||Dip >95% (0 VAC), 10.0ms|A||
|||EN55035<br>(240 VAC)|Dip 30% (168 VAC), 500ms|B||
||||Dip >95% (0 VAC), 5000ms|B||
||||Dip >95% (0 VAC), 10.0ms|A||
||||||Derate Output Power to 85 W (GCS150)|
||Dips and Interruptions|EN60601-1-2<br>(100 VAC)|Dip 60% (40 VAC), 100ms|A|Derate Output Power to 90 W (GCS180)<br>Derate Output Power to 120 W (GCS250)|
||||||Derate Output Power to 150 W (GCS350)|
||||Dip 30% (70 VAC), 500ms|A||
||||Dip >95% (0 VAC), 5000ms|B||
||||Dip >95% (0 VAC), 10.0ms|A||
|||EN60601-1-2|Dip 60% (96 VAC), 100ms|A||
|||(240 VAC)|Dip 30% (168 VAC), 500ms|A||
||||Dip >95% (0 VAC), 5000ms|B||
|Safety Approvals<br>Safety Agency<br>Safety Standard<br>Notes & Conditions<br>CB Report<br>IEC60950-1:2005 Ed 2 / IEC62368-1:2014<br>Information Technology<br>IEC60601-1 Ed 3 Including Risk Management<br>Medical<br>UL<br>UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14,<br>Information Technology<br>ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08<br>Medical<br>EN<br>EN62368-1:2014/A11:2017<br>Information Technology<br>EN60601-1/A12:2006<br>Medical<br>CE<br>LVD & RoHS<br>Equipment Protection Class<br>Class I & Class II<br>See safety agency conditions of acceptibility for details<br>Means of Protection<br>Category<br>Primary to Secondary<br>2 x MOPP (Means of Patient Protection)<br>IEC60601-1 Ed 3<br>Primary to Earth<br>1 x MOPP (Means of Patient Protection)<br>Secondary to Earth<br>1 x MOPP (Means of Patient Protection)<br>~~____~~||||||
||||**www.xppower.com**||6|
**GCS Series**
XP Power
**AC-DC Power Supplies**
## Mechanical Details ~~—6—6LULUmU~~
## **GCS150**
## **GCS180**
**==> picture [423 x 421] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note: Mounting points A should be connected<br>5.0 (127.0) together for optimum EMI performance<br>0.225 (5.72) 4.55 (115.57) 1.43<br>0.20 (5.1) (36.3)<br>So re ) Q3 T1 es C45 : A a 5<br>3.00<br>(76.2)<br>2.15<br>AIRFLOW (54.6) 2.40<br>2.55 C23 (61.0)<br>(64.77) C6 Q1 1.18<br>L3 (29.8)<br>0.61<br>A A (15.6)<br>0.225 (5.72) 0.15 (3.8)<br>0.14 (3.5) SMD Component Height<br>0.20 (5.1) i. 0.25 Faston Ground Tab 0.18 (4.6)<br>4 x 0.156 (3.96) mounting holes<br>ø.312 (7.92) clearance top and bottom<br>Note: Mounting points A should be connected<br>5.0 (127.0) together for optimum EMI performance<br>0.225 (5.72) 4.55 (115.57) 1.43<br>0.20 (5.1) (36.3)<br>i oleae k Q3 y T1 = C45 | A —_<br>3.00<br>(76.2)<br>2.15<br>AIRFLOW (54.6) 2.40<br>C23<br>2.55 (61.0)<br>(64.77) C6 Q1<br>1.18<br>(29.8)<br>0.61<br>A A (15.6)<br>0.225 (5.72) 0.15 (3.8)<br>0.14 (3.5) SMD Component Height<br>0.20 (5.1) 0.25 Faston Ground Tab | 0.18 (4.6)<br>4 x 0.156 (3.96) mounting holes<br>L3 ø.312 (7.92) clearance top and bottom<br>C28<br>C28<br>**----- End of picture text -----**<br>
|Output Connector J2|Output Connector J2||Fan Connector J3|Fan Connector J3|
|---|---|---|---|---|
|Molex pn. 09-65-2068|||Molex pn. 22-04-1021||
|Pin|Single Output||Pin|Function|
|1|+V1||1|Fan +(12 V)|
|2|+V1||2|Fan -|
|3|+V1||||
|4|RTN||||
|5|RTN||||
|6|RTN||||
|Input Connector J1|Input Connector J1|
|---|---|
|Molex pn. 09-65-2038||
|Pin|Function|
|1|Line|
|2|Neutral|
## ~~**Notes**~~
1. All dimensions in inches (mm).
4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight: 0.65 lbs (0.29 kg)
|Signal Connector J4<br>JST PN B10B-PHDSS|Signal Connector J4<br>JST PN B10B-PHDSS|
|---|---|
|Pin|Single Output|
|1|+Sense|
|2|-Sense|
|3|XP Internal Use|
|4|Inhibit LO|
|5|Inhibit HI|
|6|N/C|
|7|N/C<br>N/C|
|8|N/C|
|9|N/C|
|10|N/C|
**www.xppower.com**
7
**GCS Series**
> **AC-DC Power Supplies** XP Power
## **Mechanical Details** ~~Me~~
**GCS250 12-15 V models**
**==> picture [429 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note: Mounting points A should be connected<br>5.0 (127.0) together for optimum EMI performance<br>0.225 (5.72) 4.55 (115.57) 1.43<br>0.20 (5.1) (36.3)<br>eK O OF7 Q3 s T1 e C45 e A ) a —_<br>3.00<br>(76.2)<br>2.15<br>AIRFLOW (54.6) C23 2.40<br>2.55 (61.0)<br>—— > (64.77) =aN Q1 a E E ! = |<br>1.18<br>C6 (29.8)<br>0.61<br>A A (15.6)<br>e w Onn enen “U s: : ,lp<br>0.225 (5.72) 0.15 (3.8)<br>0.14 (3.5) SMD Component Height<br>0.20 (5.1) 0.25 Faston Ground Tab 0.18 (4.6)<br>L3 4 x 0.156 (3.96) mounting holesø.312 (7.92) clearance top and bottom<br>C28<br>**----- End of picture text -----**<br>
## **GCS250 Other models**
**==> picture [457 x 323] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note: Mounting points A should be connected<br>5.0 (127.0) together for optimum EMI performance<br>0.225 (5.72) 4.55 (115.57) 1.43<br>Q3 C45 0.20 (5.1) (36.3)<br>T1<br>7 O rt Ie A | —_<br>A L T Fo = i a eit<br>3.00<br>(76.2)<br>2.15<br>AIRFLOW (54.6) C23 2.40<br>2.55 (61.0)<br>(64.77) Q1<br>1.18<br>C6 (29.8)<br>0.61<br>A A (15.6)<br>a N Onn enen! ar | a<br>0.225 (5.72) 0.15 (3.8)<br>0.14 (3.5) SMD Component Height<br>0.20 (5.1) 0.25 Faston Ground Tab 0.18 (4.6)<br>4 x 0.156 (3.96) mounting holes<br>ø.312 (7.92) clearance top and bottom<br>L3<br>Input Connector J1 Output Connector J2 Fan Connector J3 Signal Connector J4<br>Molex pn. 09-65-2038 Molex pn. 09-65-2068 Molex pn. 22-04-1021 JST PN B10B-PHDSS<br>Pin Function Pin Single Output Pin Function Pin Single Output<br>1 Line 1 +V1 1 Fan +(12 V) 1 +Sense<br>2 Neutral 2 +V1 2 Fan - 2 -Sense<br>3 +V1 3 XP Internal Use<br>4 RTN 4 Inhibit LO<br>5 RTN 5 Inhibit HI<br>6 RTN 6 N/C<br>7 N/C<br>8 N/C<br>terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD- 9 N/C<br>10 N/C<br>C28<br>**----- End of picture text -----**<br>
## ~~**Notes**~~
**1. All dimensions in inches (mm). terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and 3. Weight: 0.65 lbs (0.29 kg) with Molex series 50802 crimp terminals.**
**4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp**
**www.xppower.com**
8
**GCS Series**
> **AC-DC Power Supplies** XP Power
## Mechanical Details ~~Ul x=~~ **GCS350 model**
**==> picture [529 x 375] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note: Mounting points A should be connected<br>together for optimum EMI performance<br>5.0 (127.0) 1.49<br>(37.8)<br>0.2 (5.72) 4.55 (115.57)<br>Q3 0.40<br>T1 (10.2)<br>A<br>+ M3 Screw<br>J1 [2] 1 - 0.5 (12.6)<br>3.0 era<br>C6<br>(76.2) 2<br>1.84 2.55 Q1 C23 1 J3 1.7<br>(46.7) (64.77) C6 35 4J4 1.18 (44.8)<br>1 2<br>0.61 (29.8)<br>A L3 (beneath heatsi nk ) A (15.6)<br>0.22 (5.72) 0.15 (3.8)<br>0.20 (5.1) 0.25 faston SMD Component height<br>ground tab M3 screw terminal bus bar<br>4 x ø.156 (3.96) mounting hole 0.18<br>ø.312 (7.92) clearance top and bottom (4.6) Standard on 12/15 V models<br>Optional on all other models,<br>add suffix ‘-S’ e.g. GCS350PS24-S<br>0.20 0.29<br>(5.1) (7.4)<br>1 6 12<br>J2<br>J2<br>6<br>12 J3(61.0)2.4 1 12 7J3<br>135 42J4 135 42J4 (40.6)1.6<br>6 Position single row 12 Position dual row<br>Standard on 24/28/48/56 V models Optional on 12/15 V models, add suffix<br>‘-J’ e.g. GCS350PS12-J<br>+<br>-<br>**----- End of picture text -----**<br>
|Input Connector J1|Input Connector J1|||Output Connector|Output Connector|Output Connector|Output Connector||Fan Connector J3|Fan Connector J3||Signal Connector J4|Signal Connector J4|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Molex pn. 09-65-2038|Molex pn. 09-65-2038|||6 position J2||6 position J2|12 position J2||Molex pn. 22-04-1021|||JST PN B10B-PHDSS||
|Pin|Function|||Molex pn. 09-65-2068|Molex pn. 09-65-2068||Molex pn. 39-28-8120||Pin|Function||Pin|Function|
|1|Line|||Pin|Function||Pin<br>Function||1|Fan +(12 V)||1|+Sense|
|2|Neutral|||1|+V1||1-3<br>RTN||2|Fan -||2|-Sense|
|||||2|+V1||4-6<br>+V1|||||3|XP Internal Use|
|||||3|+V1||7-9<br>RTN|||||4|Inhibit LO|
|||||4|RTN||10-12<br>+V1|||||5|Inhibit HI|
|||||5|RTN|||||||6|N/C|
|~~**Notes**~~||||6|RTN|||||||7<br>8|N/C<br>N/C|
|1. All dimensions in inches (mm).||||||4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates|4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates||4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates||4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates|9|N/C|
|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp|10|N/C|
1. All dimensions in inches (mm).
4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. 12 position dual row J2 mates with Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals.
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. Weight: 0.65 lbs (0.29 kg)
**www.xppower.com**
9
**GCS Series**
XP Power
**AC-DC Power Supplies**
## **Covered (-C)**
**==> picture [335 x 347] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.39<br>4.72 (120.0)<br>(10.0) 4 x M3 x 0.5 THD<br>0.12 (3.0) max<br>0.93 screw penetration<br>(23.7)<br>— ——<br>8<br>5.50 ±0.05<br> (139.7, ±1.27)<br>3.48, ±0.05<br>(88.5, ±1.27)<br>ee . | |<br>(60.7)2.39 Fe E (67.0)2.64<br>U noeae Arl 0.85<br>aloP a petaeycesCS anee e | (21.6)<br>0.25 Faston 0.45 0.43 | 0.45<br>Ground Tab (11.4) (10.8) [ _ | (11.4)<br>a :<br>seETOee A n | 1.70 |<br>a (43.2)<br>rae | bonolQu&U L]APUESLItalHalaia |<br>noaEGaristeeeSe e saeaioe e iroes —@ | l. |<br>a n ;<br> * é<br>—-—- a _ — ‘<br>————<br>r —f<br>|<br>4 x M3 x 0.5 THD | : 1.96<br>screw penetration0.12 (3.0) max | | (50.0)<br>7 a a _<br>is [—_] 0.76<br>|_| (19.3)<br>0.39 -—-—- Ue<br>(10.0) 4.72 (120.0) —<br>J1 12 1<br>J2<br>6<br>1 2 J3<br>10<br>1 2 J4<br>**----- End of picture text -----**<br>
**==> picture [434 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Connector J1 Output Connector J2 Fan Connector J3 Signal Connector J4<br>Molex pn. 09-65-2038 Molex pn. 09-65-2068 Molex pn. 22-04-1021 JST PN B10B-PHDSS<br>Pin Function Pin Single Output Pin Function Pin Single Output<br>1 Line 1 +V1 1 Fan +(12 V) 1 +Sense<br>2 Neutral 2 +V1 2 Fan - 2 -Sense<br>3 +V1 3 XP Internal Use<br>4 RTN 4 Inhibit LO<br>5 RTN 5 Inhibit HI<br>6 RTN 6 N/C<br>7 N/C<br>8 N/C<br>PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with 9 N/C<br>10 N/C<br>**----- End of picture text -----**<br>
## ~~**Notes**~~
1. All dimensions in inches (mm).
PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP).
3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn.
5. Weight: 1.05 lbs (0.48 kg)
**www.xppower.com**
10
**GCS Series**
XP Power
**AC-DC Power Supplies**
## **Top Fan (-TF)**
**==> picture [342 x 377] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.39<br>(10.0) 4.72 (120.0)<br>ee 2 x M3 x 0.5 THD<br>0.93 0.12 (3.0) max screw<br>(23.7) penetration<br>i i ©<br>)<br>5.5 (139.7)<br>SO ) I |<br>3.48<br>E T N | (88,5)<br>2.64<br>2.39 a, S i j (67.0)<br>(60.7) E:<br>0.85<br>. (21.6)<br>0.25 FastonGround Tab (11.4)0.45 (10.8)0.43 (11.4)0.45<br>a a ~ O o (57.8)2.2<br>1.7<br>area sage ed<br>ec aS (43.2)<br>@ HeeSssnneereeiNSORCR e eaeetetcere [4] i [ OK] lr:feet [ aan] : [ ee] [.] fet| Ecaeael L U 1 KLAR |<br>- f _ :a<br>a — 3<br>:<br>4 x M3 x 0.5 THD<br>0.12 (3.0) max | 1.96<br>screw penetration (50.0)<br>|<br>0.76<br>on<br>a_ i$—} (19.3)<br>0.39<br>(10.0) 4.72 (120.0)<br>J1 12 1<br>J2<br>6<br>1 2 J3<br>10<br>1 2 J4<br>**----- End of picture text -----**<br>
||Input Connector J1|Input Connector J1||Output Connector J2|Output Connector J2||Fan Connector J3|Fan Connector J3||Signal Connector J4|Signal Connector J4|
|---|---|---|---|---|---|---|---|---|---|---|---|
||Molex pn. 09-65-2038|||Molex pn. 09-65-2068|||Molex pn. 22-04-1021|||JST PN B10B-PHDSS||
|Pin||Function||Pin|Single Output||Pin|Function||Pin|Single Output|
|1||Line||1|+V1||1|Fan +(12 V)||1|+Sense|
|2||Neutral||2|+V1||2|Fan -||2|-Sense|
|||||3|+V1|||||3|XP Internal Use|
|||||4|RTN|||||4|Inhibit LO|
|||||5|RTN|||||5|Inhibit HI|
|||||6|RTN|||||6|N/C|
|||||||||||7|N/C|
|||||||||||8|N/C|
|1. All dimensions in inches (mm).|1. All dimensions in inches (mm).|1. All dimensions in inches (mm).<br>PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with|||||PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with|||9|N/C|
|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)<br>Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.|10|N/C|
## ~~**Notes**~~
1. All dimensions in inches (mm).
PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP).
3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn.
5. Weight: 1.15 lbs (0.52 kg)
**www.xppower.com**
11
**GCS Series**
XP Power
**AC-DC Power Supplies**
## Mechanical Details ~~a~~
**End Fan (-EF) GCS150/180/250**
**==> picture [489 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.35 (161.3)<br>0.43<br>(10.8)<br>1.90<br>(48.2)<br>ie ies<br>(88.5)3.48 i i 2.63 _ _<br>(66.9)<br>0.84 1.10<br>= (21.5) 8 ol ali [27.8]<br>5.50 (139.7) tL 0.45 (11.4) | 0.45 (11.4)<br>2 x M3 x 0.5 THD 0.25 Faston (Right Angle) Ground Tab<br>0.12 (3.0) max<br>screw penetration<br>1.70<br>0.93 (43.2)<br>(23.7)<br>0.39 (10.0) 4.72 (120.0)<br>4 x M3 x 0.5 THD<br>{<br>0.76 0.12 (3.0) max<br>(19.3) o8 screw penetration<br>1.96<br>(50.0)<br>0.39<br>(10.0) _|po) 4.72 (120.0) |<br>J4 2 1<br>10<br>J3 1 2<br>6<br>J2<br>1 21 J1<br>**----- End of picture text -----**<br>
**==> picture [434 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Connector J1 Output Connector J2 Fan Connector J3 Signal Connector J4<br>Molex pn. 09-65-2038 Molex pn. 09-65-2068 Molex pn. 22-04-1021 JST PN B10B-PHDSS<br>Pin Function Pin Single Output Pin Function Pin Single Output<br>1 Line 1 +V1 1 Fan +(12 V) 1 +Sense<br>2 Neutral 2 +V1 2 Fan - 2 -Sense<br>3 +V1 3 XP Internal Use<br>4 RTN 4 Inhibit LO<br>5 RTN 5 Inhibit HI<br>6 RTN 6 N/C<br>7 N/C<br>8 N/C<br>PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with 9 N/C<br>10 N/C<br>**----- End of picture text -----**<br>
## ~~**Notes**~~
1. All dimensions in inches (mm).
PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals.
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP).
3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn.
5. Weight: 1.30 lbs (0.59 kg)
**www.xppower.com**
12
XP Power
**AC-DC Power Supplies**
## **GCS Series**
## **End Fan (-EF) GCS350**
**==> picture [481 x 416] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.68 (17.3) 6.00 (152.4) 1.75 (44.4)<br>0.56 (14.2) 0.24 (6.0) 0.70<br>(17.7)<br>0.99<br>1.48 (25.1)<br>1.75<br>(37.7)<br>(44.4)<br>Ce t> , =a 0.50 (12.6) Perl<br>3.50<br>(88.9)<br>Oe i s 2.02 ees<br>1.42 (51.2)<br>0.86 (36.2)<br>(21.9)<br>| Oa Lo 1 [ 7 * |<br>Input Terminal Block 0.25 (6.4) Tt M3 Screw<br>Dinkle P/N DT-2C-A02W-03<br>0.68 (17.2) 4.72 (120.0)<br>0.88 (22.3)<br>2 X M3 X 0.5 THD<br>0.12 (3.0) Max screw penetration<br>0.68 (17.2) 4.72 (120.0)<br>0.75 (18.9)<br>fi[e sie<br>S | * | 2.00 (50.8)<br>| kg<br>4 X M3 X 0.5 THD<br>0.12 (3.0) Max screw penetration<br>**----- End of picture text -----**<br>
|Output Connector|Output Connector|Output Connector<br>Output Connector||Fan Connector J3||
|---|---|---|---|---|---|
|6 position J2||12 position J2||Molex pn. 22-04-1021||
|Molex pn. 09-65-2068|Molex pn. 09-65-2068<br>Molex pn. 39-28-8120|||Pin<br>Function||
|Pin|Function|Pin<br>Function||1<br>Fan +(12 V)||
|1|+V1|1-3<br>RTN||2<br>Fan -||
|2|+V1|4-6<br>+V1||||
|3|+V1|7-9<br>RTN||||
|4|RTN|10-12<br>+V1||||
|5|RTN|||||
|6|RTN|||||
||4. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both|4. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both||||
|2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)||with Molex series 5194 crimp terminals. 12 position dual row J2 mates with||||
|||Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals.||||
|||J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802||J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802||
|||crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST||||
|||SPHD-001T-P0.5 crimp terminals.||||
|Input Connector J1|
|---|
|Dinkle PN|
|DJ-26-AD2W-03|
|Pin<br>Function|
|1<br>Line|
|2<br>Neutral|
|3|
|~~**Notes**~~|
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. Weight: 0.65 lbs (0.29 kg)
|Signal Connector J4|Signal Connector J4|
|---|---|
|JST PN B10B-PHDSS||
|Pin|Function|
|1|+Sense|
|2|-Sense|
|3|XP Internal Use|
|4|Inhibit LO|
|5|Inhibit HI|
|6|N/C|
|7|N/C|
|8|N/C|
|9|N/C|
|10|N/C|
**www.xppower.com**
13
**GCS Series**
XP Power
**AC-DC Power Supplies**
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations.
|Temperature Measurements|Temperature Measurements|
|---|---|
|Component|Max Temperature °C|
|T1 Coil|120 ° C|
|L3 Coil|120 ° C|
|Q1 Body|120 ° C|
|Q3 Body|120 ° C|
|C6|105 ° C|
|C23|105 ° C|
## -- Service Life
The estimated service life of the GCS Series is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative service life in 24/7 operation.
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature.
## **Estimated Service Life vs Component Temperature**
**==> picture [528 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
GCS150/180 GCS250 GCS350<br>185000<br>120000 70000 165000<br>100000 60000 145000<br>80000 50000 125000<br>40000 105000<br>60000 85000<br>30000<br>40000 20000 6500045000<br>20000 10000 25000<br>0 0 5000<br>105 95 85 75 65 55 105 95 85 75 65 55 105 95 85 75 65 55<br>SF C6 Temperature (°C) = C6 Temperature (°C) C6 Temperature (°C)<br>GCS150/180 GCS250 GCS350<br>185000 185000<br>185000<br>165000 165000<br>165000<br>145000 145000<br>145000<br>125000 125000<br>125000<br>105000 105000<br>105000<br>85000 85000<br>85000<br>65000 65000<br>65000<br>45000 45000<br>45000<br>25000 25000<br>25000<br>5000 5000<br>5000 105 95 85 75 65 55 105 95 85 75 65 55<br>105 95 85 75 65 55<br>C23 Temperature (°C) C23 Temperature (°C)<br>C23 Temperature (°C)<br>Lifetime (Hrs) Lifetime (Hrs) Lifetime (Hrs)<br>Lifetime (Hrs) Lifetime (Hrs)<br>Lifetime (Hrs)<br>**----- End of picture text -----**<br>
**www.xppower.com**
20 July 2022
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →