Image not available
Illustrative purposes only
GBK1420
GROUND BAR KIT
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Circuit Breaker Accessories
- For Use With:Type CH Loadcenters & Circuit Breakers; Accessory Type:Ground Bar; Product Range:- 47K8369
- SVHC: No SVHC (17-Dec-2015)
- For Use With: Type CH Loadcenters & Circuit Breakers
- Product Range: -
- Accessory Type: Ground Bar
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 48.26 € |
| Current stock | 10+ |
| Lead time | 30 days |
Loadcenters ## **BR Renovation and CH Loadcenters** ## **5 Loadcenters** |**Loadcenters**||**1**| |---|---|---| |Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-2**|**1**| |Product History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Type CH Family. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-2**<br>**V12-T5-2**|**2**| |Type BR Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Product History Time Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-2**<br>**V12-T5-3**|**3**| |Replacement Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Type CH Replacement Parts and Mechanical Interlocks. . . . . . . . .|**V12-T5-4**<br>**V12-T5-4**|**4**| |Type CH Vintage Replacement Covers . . . . . . . . . . . . . . . . . . . . . .<br>Type BR Replacement Parts and Covers . . . . . . . . . . . . . . . . . . . .|**V12-T5-12**<br>**V12-T5-14**|**5**| |Classified Replacement Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Type CL and CHQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-24**<br>**V12-T5-24**|**6**| |Type CHNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Type CTL and CHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-24**<br>**V12-T5-24**|**7**| |Technology Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Renovation Loadcenter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-25**<br>**V12-T5-25**|**8**| |Plug-On Neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Retrofit Interiors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-26**<br>**V12-T5-27**|**9**| |Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Further Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-29**<br>**V12-T5-30**|**10**| |Pricing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V12-T5-30**|**11**| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-1** Loadcenters 5 ## **Product Description** Loadcenters are enclosed assemblies used for power **2** distribution and circuit protection in residential, commercial and light **3** industrial applications. The assembly consists of an enclosure, an interior **4** assembly and a cover. The interior assembly consists **5** of a backpan where the bus assembly is mounted. Incoming power is **6** terminated at main lugs or a main circuit breaker. Load circuit protection is provided **7** by molded-case circuit breakers that plug onto the bus assembly. Loadcenters are used on services providing no more than 240 Vac, and are available with bus rated from 40 to 600A. Loadcenter covers are available as surface, flush or combination. ## **Product History** ## **Type CH Family** Eaton’s electrical business began manufacturing the CH series of loadcenters and circuit breakers in 1962. Changes have occurred over the years due to code changes, UL[®] listed requirements and product enhancements. Three major design changes occurred in 1969, 1982 and 1995. The 3/4-inch wide feeder circuit breakers, silver flash plated copper bus, sandalwood (tan) painted box and industryleading warranties have been the trademarks of this premium product through the years. ## **Type BR Family** With the acquisition of Westinghouse’s Distribution and Control Business Unit (DCBU) in 1994, Eaton gained the circuit breaker and loadcenter manufacturing and marketing operations of Westinghouse. Prior to 1989, these products were manufactured by Westinghouse’s Bryant subsidiary in Bridgeport, CT. The products from this facility bore the Westinghouse and Bryant nameplates. In 1988, Westinghouse purchased Challenger Electric, redesigned the product, and moved all production from Bridgeport to Jackson, MS. As Eaton integrated the product lines in 1995, all loadcenter production shifted to the Lincoln, IL, facility. ## **Type CH Loadcenter** **==> picture [100 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> “Tangential” Center Knockout for<br>easier installation<br>Single Keyhole Mounting<br>Just one keyhole at top and bottom<br>for easier mounting and leveling.<br>Unique Sandalwood Finish<br>Immediately recognizable,<br>aesthetically appealing, scratch-<br>resistant powder coating.<br>**----- End of picture text -----**<br> Extra 1.50-Inch (38.1 mm) Knockout for Bundling Provides for easier installation, less installation time. Top or Bottom Feed ■ Straight-in wiring saves labor and material ■ Only one panel for either application— no modifications necessary Commercial Grade Main Breaker ■ 35 kAIC series rated main breaker in 150 and 200A loadcenters ■ 42 and 100 kAIC series ratings available Drywall Marking on Enclosure Indicates proper mounting depth for flush applications. One-Piece Silver Flash Plated Copper Bus Provides superior conductivity throughout the entire product line. **==> picture [497 x 241] intentionally omitted <==** **----- Start of picture text -----**<br> Separately Packaged Covers<br>■ Full line of “true” surface and<br>Commercial Grade Main Breaker<br>combination covers<br>■ 35 kAIC series rated main breaker in<br>■ Built-in flush leveling feature<br>150 and 200A loadcenters<br>■ Choice of circuit identification by<br>■ 42 and 100 kAIC series ratings available<br>breaker labels or circuit directory<br>Drywall Marking on Enclosure Neutral Design<br>Indicates proper mounting depth for (for styles as indicated)<br>flush applications. ■ Bonding strap is easily removable<br>for sub-panel applications<br>providing a ground and neutral<br>One-Piece Silver Flash Plated Copper Bus ■ Factory-bonded for service<br>Provides superior conductivity throughout the entrance applications providing<br>entire product line. a split neutral<br>■ Ample additional 2/0 lugs<br>provided; no kits necessary<br>■ 200% size neutral<br>Steel Backpan<br>■ Provides positive, reliable breaker mounting<br>■ One-piece designed for stability<br>Convertible Styles Available /<br>■ Uses field-installable main breaker or main ? Improved Endwall Knockouts<br>lug kits<br>Larger KOs are balanced to enhance<br>■ Flexible inventory—same breaker is used in installed appearance and to ease<br>loadcenter and circuit breaker enclosures use of existing wiring.<br>**----- End of picture text -----**<br> **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-2** Loadcenters 5 ## **GBK14** ## **Replacement Ground Bar Kits** **Description (See Legend)** |||||||**1**| |---|---|---|---|---|---|---| ||||**Length**|**Ordering**|**Catalog**|**1**| |||dssssds|**Inches (mm)**<br>2.54 (64.5)|**Quantity**1<br>1|**Number**<br>**GBK5**2|**2**| |||dssssdsj<br>dssssdssssss|3.59 (91.2)<br>4.29 (109.0)|1<br>1|**GBK520**2<br>**GBK10**2|**3**| |||dssssdssssssj|5.34 (135.6)|1|**GBK1020**2|| |||f<br>d<br>f<br>f<br>f<br>k<br>f<br>d<br>f<br>k<br>f<br>f<br>f<br>k<br>f|4.61 (117.1)|1|**GBK13**2|**4**| |||dssssdssssssssss|5.69 (144.5)|1|**GBK14**2|| ||dssssdssssssssssj||6.74 (171.2)|1|**GBK1420**2|**5**| |dssssdsssssssssssssssss|||8.14 (206.8)|1|**GBK21**2|| |dssssdsssssssssssssssssj|||9.19 (233.4)|1|**GBK2120**2|**6**| |ssssssssdssssssdsssssss|||7.94 (201.7)|1|**CH9GP21**34|| |f|k|f<br>d<br>f<br>k<br>f<br>f<br>f<br>k<br>f<br>d<br>f<br>k<br>f<br>f<br>f<br>k<br>f|5.78 (146.8)|1|**BRGBK39512**56|**7**| |||sssss|1.84 (46.7)|1|**GB4NM**7|| ## **Ground Bar Legend** - s = (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al j = (1) #6–2/0 Cu/Al = (1) 1/0–14 or (3) #10–12 Cu/Al = (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al - d = Mounting hole ## **Product History Time Line** **Originally a Cutler-Hammer Product—3/4-Inch Non-Interchangeable Product Line** Door latch is tan plastic, twin neutrals, CH8_S or F. (Blank is 1 letter indicating box size, i.e., B, C, E, J, K.) ~~_—LE oe ee~~ Metal latch, single neutral, CH7_S or F. (Blank is 2 letters indicating box size, i.e., BB, CC, JJ, KK.) ~~— ee ee~~ 2 ~~EE ee~~ Cover catalog numbers CH7_S or F. (Blank is 1 letter indicating box size, i.e., B, C, D, 3, G, J, K.) ~~— LETTE LE LL~~ ## **Originally a Westinghouse Product—1-Inch Interchangeable Product Line** ## _**Notes**_ - 1 Must be purchased in multiples of ordering quantities indicated. - 2 Distance between mounting holes is 1.75 inches (44.5 mm). - 3 For single- and three-phase 400 A loadcenters. - 4 Distance between mounting holes is 2.40 inches (61.0 mm). - 5 For single- and three-phase 400 and 600 A applications. - 6 Distance between mounting holes is 2.34 inches (59.5 mm). - 7 For non-metallic enclosures. Snaps into molded base. - 8 CH and BR are the current product designations. CH1, CH2, BR1, BR2 and BR3 are used only to identify previous generations of the product described in the replacement capabilities chart above. These are not actual product designations. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-3** Loadcenters 5 Type CH ## **Replacement Capabilities** ## **Replacement Capabilities** **5** |**Type**|**Type**||**Loadcenter Generations**|**Loadcenter Generations**|||||| |---|---|---|---|---|---|---|---|---|---| |**Part**1|||**CH**|**CH1**|**CH2**|**BR**|**BR1**|**BR2**|**BR3**| |Breakers|||■|■|■|■|■|■|■| |Surge arresters|||■|■|■|■|■|■|■| |Covers|||■|■||■|■||| |Deadfronts (NEMA®3R)|||■|■||■|■||| |Door assemblies (NEMA 3R)|||■|■||■|■||| |MCB kits|||■|■||■|■||| |Neutral bars|||■|■|■|■|■|■|■| |Ground bars|||■|■|■|■|■|■|■| |Breaker accessories|||■|■|■|■|■|■|■| |Labels|||■|■|■|■|■|■|■| |Lugs|||■|■||■|■||| |Door locks|||■|■|■|■|||| |Door latches|||■|||■|||| |Paint|||■|■|■|■|■|■|■| |Closure plates<br>Hubs|||■<br>■|■<br>■|■|■<br>■|■<br>■|■|■| |Spare parts kit<br>Whole house AC surge protection|||■<br>■|■|■|■<br>■|■|■|■| |||**Type CH Replacement Parts**|||||||| |||**Description**||||**Ordering Quantity**|**Ordering Quantity**2|**Catalog Number**|| |**CHSF2125**||Subfeed lug blocks—two-pole, 125 A, 3/4-inch (19.1 mm) spaces needed||Subfeed lug blocks—two-pole, 125 A, 3/4-inch (19.1 mm) spaces needed||1||**CHSF2125**|| |**CHSF3125**||Subfeed lug blocks—three-pole, 125 A, 3/4-inch (19.1 mm) spaces needed||||1||**CHSF3125**|| |**NL20**||Neutral/ground lug—add-on neutral or ground lug||||1||**NL20**|| |**NL30**<br>**NL300**<br>Be||||||1<br>1||**NL30**<br>**NL300**|| ||@001||||||||| |**CHFP**||Filler plates—3/4-inch (19.1 mm) space circuit breaker space||||25||**CHFP**|| ## _**Notes**_ 1 Catalog number of loadcenter required to obtain correct part. - 2 Must be purchased in multiples of ordering quantities indicated. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-4** Loadcenters 5 Type CH |||**Type CH Replacement Parts, continued**<br>**Description**|**Ordering Quantity**1|**Catalog Number**|**1**| |---|---|---|---|---|---| |CSR main circuit breaker filler plate (with hardware)<br>**CSRFP**<br>aa|||1|**CSRFP**|**2**<br>**3**| |~~Se~~|**TDL**<br>~~Se~~|Door lock—12–42 circuits, and 100–225 A<br>~~Se~~|1|**TDL**|**4**<br>**5**| |**SPCSW**||Sandlewood spray paint|1|**SPCSW**|| ||||||**6**| ||||||**7**| ||**SPC61**|ANSI-61 light gray touchup paint for outdoor loadcenters|1|**SPC61**|**8**| |:|||||**9**<br>**10**| ||Isolated neutral assembly (computer circuits)<br>**BINA**<br>~~=~~||1|**BINA**|**11**<br>**12**| ||**TCD**|Circuit directory—adhesive backed|10|**TCD**|| ||||||**13**| |Cover screws<br>**LCCS**<br>~~=~~|||25|**LCCS**|**14**<br>**15**<br>**16**| |**CHRLS**||Cover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only|1|**CHRLS**|| |HH|||||**17**| |||Cover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only|1|**CHRLS (white version)**|**18**| ||||||**18**| |||**_Note_**|||| |||1Must be purchased in multiples of ordering quantities indicated.|||**19**| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-5** Loadcenters 5 Type CH **5** ~~—_~~ **6** ||||**Type CH Replacement Parts, continued**<br>**Description**|**Ordering Quantity**1|**Catalog Number**| |---|---|---|---|---|---| |**CHMS**|||Circuit marking strip (next to breakers)|1|**CHMS**| |**CHBL**<br>**SRL**|||Circuit identification label (preprinted breaker labels next to breakers)<br>Series rated caution label|10<br>25|**CHBL**<br>**SRL**| |**CHNS**<br>=:|||Branch circuit numbering strip|25|**CHNS**| |Ee|||||| |**BSSUSE**|||Bonding strap with screw|20|**BSSUSE**| |es|es||||| |**CH125RB**|||125 A retainer bracket for sub-fed devices|1|**CH125RB**| |—|Sa||||| |**CH3RLATCH**|||Replacement lock 400 A devices<br>Replacement latch for NEMA 3R—four circuits and above|1<br>1|**52-2751**<br>**CH3RLATCH**| |=-ou|=-ou|T|**_Note_**<br>Lock for vintage CH7 cover|1|**CH9FL**| ||||1Must be purchased in multiples of ordering quantities indicated.||| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-6** Loadcenters 5 Type CH ## **Breaker Replacement Accessories** ||**Breaker Replacement Accessories**||| |---|---|---|---| |||**Ordering**|**Catalog**| ||**Description**|**Quantity**1|**Number**| |**CHHT**|**Handle Ties**2||| |a),|Handle tie bar for physically joining the handles of two adjacent single-pole Type CH circuit breakers (molded plastic handle cover)|25|**CHHT**| |**CHPL**|**Handle Lockoffs **34||| |ye|Padlockable device for locking the handle of single-, two- or three-pole Type CH circuit breakers (escutcheon mounted)5|1|**CHPL**| |**CHPLGF**|Padlockable device for locking the handle of a single-, two- or three-pole Type CHGFI circuit breaker (escutcheon mounted)5|1|**CHPLGF**| |**CCPL**|Padlockable device for locking the handle of main circuit breaker Types CC and CCH into the ON or OFF position.(screw mounted)6|1|**CCPL**| |**MCBPL**|Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon mounted)5|1|**MCBPL**| |**CHLO**|**Handle Lockdogs **47||| |& 2 & «6|Device used to secure handle in ON or OFF position for single-pole Type CH circuit breakers (handle mounted)8|10|**CHLO**| |**CH125RB**|**Hold-Down Kits **9||| ||Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers. For 6–24 circuit 125 A single- and three-phase,|1|**CH125RB**| ||12–42 circuit single-phase 225 A and 24–42 circuit three-phase 225 A MLO Type CH loadcenters||| |a:<br>_™~<br>*|||| |**CH125RB24**|Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers for 2–4 circuit MLO CH loadcenters.|1|**CH125RB24**| **5** ## _**Notes**_ - 1 Must be purchased in multiples of ordering quantities indicated. - 2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker. - 3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position. - 4 Requires one additional pole space. - 5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront. - 6 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw. - 7 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle lockdogs are not padlockable devices. - 8 Handle mounted: device mounted above or below handle using spring pressure. - 9 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g). **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-7** Loadcenters 5 Type CH **5 6** ~~mm 08,~~ ## **Breaker Replacement Accessories, continued** ||**Breaker Replacement Accessories, continued**||| |---|---|---|---| |||**Ordering**|**Catalog**| ||**Description**|**Quantity**1|**Number**| |**CH9MB270**|**Mounting Bases**||| |E|Mounting base for two-pole Type CH circuit breaker—70 A maximum|1|**CH9MB270**| |**CCL300**<br>**MCBL300**<br>~~08,~~|**Main Breaker Lug Kits**<br>Types CC and CCH main breaker lug kit (2) 300 kcmil<br>Type CSR main breaker lug kit (2) 300 kcmil|1<br>1|**CCL300**<br>**MCBL300**| |**Mechanical Interlock**<br>Type CH for two-, three- and four-pole breakers<br>**CHML**<br>"e||10|**CHML**| |**CHPLOFF**|Type CH for two-, three- and four-pole breakers|10|**CHPLOFF**| |Type CH for two-, three- and four-pole breakers<br>**CHPLOFFA**<br>~~2~~||10|**CHPLOFFA**| |ee|||| ||CH 3/4-inch loadcenter and breaker accessories, handle lockdog|10|**CHL1P**| |||10|**CHL2P**| ## _**Note**_ 1 Must be purchased in multiples of ordering quantities indicated. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-8** Loadcenters 5 Type CH ## _**Renewal Parts List for Type CH Loadcenter Covers and Deadfronts**_ ## **Single-Phase with Main Circuit Breaker** |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**|**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |---|---|---|---|---|---|---|---|---|---| |**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**|**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**| |**CH1420B100B**|CH8BF|CH8BS|—|—|**CH30B125R**|—|—|CH3RDOOR10|CH3RDF6| |**CH1420B100R**|— —|—|CH3RDOOR5|CH3RDF4|**CH3242B200J**|CH8JF|CH8JS|—|—| |**CH14B100B**|CH8BF|CH8BS|—|—|**CH3242B200R**|—|—|CH3RDOOR12|CH3RDF9| |**CH14B100R**|—|—|CH3RDOOR5|CH3RDF4|**CH32B150J**|CH8JF|CH8JS|—|—| |**CH1824B100C**|CH8CF|CH8CS|—|—|**CH32B150R**|—|—|CH3RDOOR12|CH3RDF9| |**CH1824B100R**|—|—|CH3RDOOR8|CH3RDF5|**CH32B200J**|CH8JF|CH8JS|—|—| |**CH18B100C**|CH8CF|CH8CS|—|—|**CH32B200R**|—|—|CH3RDOOR12|CH3RDF9| |**CH18B100R**|—|—|CH3RDOOR8|CH3RDF5|**CH32B225J**|CH8JF|CH8JS|—|—| |**CH20H100C**|CH8CF|CH8CS|—|—|**CH32B225R**|—|—|CH3RDOOR12|CH3RDF9| |**CH20H100R**|—|—|CH3RDOOR7|CH3RDF5|**CH32H150L**|CH8LF|CH8LS|—|—| |**CH22B100C**|CH8CF|CH8CS|—|—|**CH32H150R**|—|—|CH3RDOOR6|CH3RDF10| |**CH22B100R**|—|—|CH3RDOOR7|CH3RDF5|**CH32H200L**|CH8LF|CH8LS|—|—| |**CH22B125C**|CH8CF|CH8CS|—|—|**CH32H200R**|—|—|CH3RDOOR6|CH3RDF11| |**CH22B125R**|—|—|CH3RDOOR8|CH3RDF5|**CH42B200K**|CH8KF|CH8KS|—|—| |**CH24B150E**|CH8EF|CH8ES|—|—|**CH42B200R**|—|—|CH3RDOOR13|CH3RDF10| |**CH24B150R**|—|—|CH3RDOOR11|CH3RDF7|**CH42B225K**|CH8KF|CH8KS|—|—| |**CH24B200E**|CH8EF|CH8ES|—|—|**CH42B225R**|—|—|CH3RDOOR13|CH3RDF10| |**CH24B200R**|—|—|CH3RDOOR11|CH3RDF7|**CH42H200L**|CH8LF|CH8LS|—|—| |**CH28H100D**|CH8DF|CH8DS|—|—|**CH42H200R**|—|—|CH3RDOOR6|CH3RDF11| |**CH28H100R**|—|—|CH3RDOOR9|CH3RDF6|**CH42H225L**|CH8LF|CH8LS|—|—| |**CH28H125D**|CH8DF|CH8DS|—|—|**CH42H225R**|—|—|CH3RDOOR6|CH3RDF11| |**CH28H125R**|—|—|CH3RDOOR9|CH3RDF6|**CH42PM300**|CH7PMF (flush)|CH7PMS|—|—| |**CH30B100D**|CH8DF|CH8DS|—|—|**CH42PM400**|CH7PMF (flush)|CH7PMS|—|—| |**CH30B100R**|—|—|CH3RDOOR10|CH3RDF6|**CH8B150RF**|—|—|CH3RDOOR11|CH3RDF7| |**CH30B125D**|CH8DF|CH8DS|—|—|**CH8B200RF**|—|—|CH3RDOOR11|CH3RDF7| **5** **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-9** Loadcenters 5 ## Type CH ## **Single-Phase with Main Lugs** **5** |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**|**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |---|---|---|---|---|---|---|---|---|---| |**Number**<br>**CH4L125RP**|**Covers**<br>—|**Covers**<br>—|**Covers**<br>CH3RDOOR2|**Deadfronts**<br>CH3RDF2|**Number**<br>**CH2L125SP**|**Covers**<br>—|**Covers**<br>CH82S|**Covers**<br>—|**Deadfronts**<br>—| |**CH12L125B**<br>**CH12L125R**|CH8BF<br>—|CH8BS<br>—|—<br>CH3RDOOR5|—<br>CH3RDF4|**CH2L40FP**<br>**CH2L40RP**|—<br>—|—<br>—|—<br>BKRCVR|—<br>—| |**CH12L200D**<br>**CH12L200R**|CH8DF<br>—|CH8DS<br>—|—<br>CH3RDOOR9|—<br>CH4RDF6|**CH2L40SP**<br>**CH2L70FP**|—<br>—|—<br>—|—<br>—|—<br>—| |**CH1624L125B**<br>**CH1624L125R**|CH8BF<br>—|CH8BS<br>—|—<br>CH3RDOOR5|—<br>CH3RDF4|**CH2L70RP**<br>**CH2L70SP**|—<br>—|—<br>—|BKRCVR<br>—|—<br>—| |**CH16L125B**|CH8BF|CH8BS|—|—|**CH3242L225D**|CH8DF|CH8DS|—|—| |**CH16L125R**|—|—|CH3RDOOR5|CH3RDF4|**CH3242L225R**|—|—|CH3RDOOR11|CH3RDF6| |**CH16L200D**|CH8DF|BH8DS|—|—|**CH32L150D**|CH8DF|CH8DS|—|—| |**CH16L200R**|—|—|CH3RDOOR11|CH3RDF6|**CH32L150R**|—|—|CH3RDOOR11|CH3RDF6| |**CH20L125C**|CH8CF|CH8CS|—|—|**CH32L225D**|CH8DF|CH8DS|—|—| |**CH20L125R**|—|—|CH3RDOOR8|CH3RDF5|**CH32L225R**|—|—|CH3RDOOR11|CH3RDF6| |**CH24L125C**|CH8CF|CH8CS|—|—|**CH42L225G**|CH8GF|CH8GS|—|—| |**CH24L125R**|—|—|CH3RDOOR8|CH3RDF5|**CH42L225R**|—|—|CH3RDOOR12|CH3RDF8| |**CH24L150D**|CH8DF|CH8DS|—|—|**CH42PL400**|CH7PF (flush)|CH7PS|—|—| |**CH24L150R**|—|—|CH3RDOOR11|CH3RDF6|**CH4L125FP**|CH84F (flush)|—|—|—| |**CH24L225D**|CH8DF|CH8DS|—|—|**CH4L125SP**|—|CH84S|—|—| |**CH24L225R**|—|—|CH3RDOOR11|CH3RDF6|**CH8L125FP**|CH88F (flush)|—|—|—| |**CH2L125FP**|CH82F (FLUSH)|—|—|—|**CH8L125RP**|—|—|CH3RDOOR4|CH3RDF3| |**CH2L125RE2P**|—|—|—|—|**CH8L125SP**|—|CH88S|—|—| |**CH2L125RP**|—|—|CH3RDOOR1|CH3RDF1|||||| ## **Single-Phase Convertible** |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |---|---|---|---|---| |**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**| |**CH22N125C**|CH8CF|CH8CS|—|—| |**CH22N125R**|—|—|—|—| |**CH32N200J**|CH8JF|CH8JS|—|—| |**CH32N200R**|—|—|CH3RD00R12|CH3RDF9| |**CH42N225K**|CH8KF|CH8KS|—|—| |**CH42N225R**<br>**CH8N200RF**|—<br>—|—<br>—|—<br>—|—<br>CH3RDF7| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-10** Loadcenters 5 **5** ## Type CH ## **Three-Phase with Main Circuit Breakers** ## **Three-Phase with Main Lugs** |**Catalog**<br>**Number**<br>**Combination**<br>**Covers**<br>**Surface**<br>**Covers**<br>**NEMA 3R**<br>**Covers**<br>**NEMA 3R**<br>**Deadfronts**<br>**CH30B3150L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH30B3150R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH30B3200L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH30B3200R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH30B3225L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH30B3225R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH30H3200L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH30H3200R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH424PM300**<br>CH7PMF (flush)<br>CH7PMS<br>—<br>—<br>**CH424PM400**<br>CH7PMF (flush)<br>CH7PMS<br>—<br>—<br>**CH42B3200L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH42B3200R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH42B3225L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH42B3225R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH42H3200L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH42H3200R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11<br>**CH42H3225L**<br>CH8LF<br>CH8LS<br>—<br>—<br>**CH42H3225R**<br>—<br>—<br>CH3RDOOR6<br>CH3RDF11|**Catalog**<br>**Number**<br>**Combination**<br>**Covers**<br>**Surface**<br>**Covers**<br>**NEMA 3R**<br>**Covers**<br>**NEMA 3R**<br>**Deadfronts**| |---|---| ||**CH12L3125B**<br>CH8BF<br>CH8BS<br>—<br>—| ||**CH12L3125R**<br>—<br>—<br>CH3RDOOR5<br>CH3RDF4| ||**CH18L3125C**<br>CH8CF<br>CH8CS<br>—<br>—| ||**CH18L3125R**<br>—<br>—<br>CH3RDOOR8<br>CH3RDF5| ||**CH24L3125C**<br>CH8CF<br>CH8CS<br>—<br>—| ||**CH24L3125R**<br>—<br>—<br>CH3RDOOR8<br>CH3RDF5| ||**CH24L3225D**<br>CH8DF<br>CH8DS<br>—<br>—| ||**CH24L3225R**<br>—<br>—<br>CH3RDOOR11<br>CH3RDF6| ||**CH30L3150D**<br>CH8DF<br>CH8DS<br>—<br>—| ||**CH30L3150R**<br>—<br>—<br>CH3RDOOR11<br>CH3RDF6| ||**CH30L3225D**<br>CH8DF<br>CH8DS<br>—<br>—| ||**CH30L3225R**<br>—<br>—<br>CH3RDOOR11<br>CH3RDF6| ||**CH424PL400**<br>CH7PF (flush)<br>CH7PS<br>—<br>—| ||**CH42L3225R**<br>—<br>—<br>CH3RDOOR12<br>CH3RDF8| ||**CH42L3225G**<br>CH8GF<br>CH8GS<br>—<br>—| ||**CH6L3125FP**<br>CH86F (flush)<br>—<br>—<br>—| ||**CH6L3125RP**<br>—<br>—<br>CH3RDOOR3<br>CH3RDF3| ||**CH6L3125SP**<br>—<br>CH86F<br>—<br>—| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-11** Loadcenters 5 Type CH ## _**Renewal Parts List for Vintage Type CH Loadcenter Covers and Deadfronts**_ **5** **Single-Phase with Main Circuit Breaker** ## **Single-Phase with Main Lugs** |**Catalog**<br>**Number**<br>**Surface**<br>**Covers**<br>**Flush**<br>**Covers**<br>**Surface Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**Flush Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**CH22CCM100N**<br>CH7CCS<br>CH7CCF<br>CH7CCSM<br>CH7CCFM<br>**CH30JJM150N**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH30JJM200N**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH40KKM200N**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH14BBM100**<br>CH7BBS<br>CH7BBF<br>CH7BBSM<br>CH7BBFM<br>**CH14BBM100R**<br>—<br>—<br>—<br>—<br>**CH18CCM100**<br>CH7CCS<br>CH7CCF<br>—<br>—<br>**CH18CCM100R**<br>—<br>—<br>—<br>—<br>**CH22CCM125**<br>CH7CCS<br>CH7CCF<br>—<br>—<br>**CH22CCM125R**<br>—<br>—<br>—<br>—<br>**CH20JJM150**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH20JJM150R**<br>—<br>—<br>—<br>—<br>**CH20JJM200**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH20JJM200R**<br>—<br>—<br>—<br>—<br>**CH24JJM150**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH24JJM150R**<br>—<br>—<br>—<br>—<br>**CH24JJM200**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH24JJM200R**<br>—<br>—<br>—<br>—<br>**CH30JJM150**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH30JJM150R**<br>—<br>—<br>—<br>—<br>**CH30JJM200**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH30JJM200R**<br>—<br>—<br>—<br>—<br>**CH30KKM225**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH30KKM225R**<br>—<br>—<br>—<br>—<br>**CH40KKM200**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH40KKM200R**<br>—<br>—<br>—<br>—<br>**CH42KKM225**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH42KKM225R**<br>—<br>—<br>—<br>—<br>**CH42PM300**<br>CH7PMS<br>CH7PMF<br>—<br>—<br>**CH42PM400**<br>CH7PMS<br>CH7PMF<br>—<br>—<br>**CH20CCM100H2**<br>CH7CCS<br>CH7CCF<br>—<br>—<br>**CH20CCM100H2R**<br>—<br>—<br>—<br>—<br>**CH26EEM125H2**<br>CH7EES<br>CH7EEF<br>—<br>—<br>**CH26EEM125H2R**<br>—<br>—<br>—<br>—<br>**CH20CCM100H4**<br>CH7CCS<br>CH7CCF<br>—<br>—<br>**CH20CCM100H4R**<br>—<br>—<br>—<br>—<br>**CH26EEM100H4**<br>CH7EES<br>CH7EEF<br>—<br>—<br>**CH26EEM100H4R**<br>—<br>—<br>—<br>—<br>**CH26EEM125H4**<br>CH7EES<br>CH7EEF<br>—<br>—<br>**CH26EEM125H4R**<br>—<br>—<br>—<br>—<br>**CH30JJM150H**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH30JJM150HR**<br>—<br>—<br>—<br>—<br>**CH30JJM200H**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH30JJM200HR**<br>—<br>—<br>—<br>—<br>**CH40KKM200H**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH40KKM200HR**<br>—<br>—<br>—<br>—<br>**CH42KKM225H**<br>CH7KKS<br>CH7KKF<br>—<br>—<br>**CH42KKM225HR**<br>—<br>—<br>—<br>—<br>**CH1420BBM100**<br>CH7BBS<br>CH7BBF<br>—<br>—<br>**CH1420BBM100R**<br>—<br>—<br>—<br>—<br>**CH1824CCM100**<br>CH7CCS<br>CH7CCF<br>—<br>—<br>**CH1824CCM100R**<br>—<br>—<br>—<br>—<br>**CH3040JJM200**<br>CH7JJS<br>CH7JJF<br>—<br>—<br>**CH3040JJM200**<br>—<br>—<br>—<br>—|**Catalog**<br>**Number**<br>**Surface**<br>**Covers**<br>**Flush**<br>**Covers**<br>**Surface Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**Flush Covers**<br>**w/ Mechanical**<br>**Interlock**| |---|---| ||**CH2S**<br>—<br>—<br>—<br>—| ||**CH2F**<br>—<br>—<br>—<br>—| ||**CH2R**<br>—<br>—<br>—<br>—| ||**CH2AS**<br>—<br>—<br>—<br>—| ||**CH2AF**<br>—<br>—<br>—<br>—| ||**CH2AR**<br>—<br>—<br>—<br>—| ||**CH2BS**<br>—<br>—<br>—<br>—| ||**CH2BF**<br>—<br>—<br>—<br>—| ||**CH2BR**<br>—<br>—<br>—<br>—| ||**CH4S**<br>—<br>—<br>—<br>—| ||**CH4F**<br>—<br>—<br>—<br>—| ||**CH4R**<br>—<br>—<br>—<br>—| ||**CH8S**<br>—<br>—<br>—<br>—| ||**CH8F**<br>—<br>—<br>—<br>—| ||**CH8R**<br>—<br>—<br>—<br>—| ||**CH12BB**<br>CH7BBS<br>CH7BBF<br>CH7BBSM<br>CH7BBFM| ||**CH12BBR**<br>—<br>—<br>—<br>—| ||**CH12EE200**<br>CH7EES<br>CH7EEF<br>—<br>—| ||**CH12EE200R**<br>—<br>—<br>—<br>—| ||**CH16BB**<br>CH7BBS<br>CH7BBF<br>CH7BBSM<br>CH7BBFM| ||**CH16BBR**<br>—<br>—<br>—<br>—| ||**CH16EE200**<br>CH7EES<br>CH7EEF<br>—<br>—| ||**CH16EE200R**<br>—<br>—<br>—<br>—| ||**CH20CC**<br>CH7CCS<br>CH7CCF<br>CH7CCSM<br>CH7CCFM| ||**CH20CCR**<br>—<br>—<br>—<br>—| ||**CH24CC**<br>CH7CCS<br>CH7CCF<br>CH7CCSM<br>CH7CCFM| ||**CH24CCR**<br>—<br>—<br>—<br>—| ||**CH24EE150**<br>CH7EES<br>CH7EEF<br>CH7EESM<br>CH7EEFM| ||**CH24EE150R**<br>—<br>—<br>—<br>—| ||**CH24EE225**<br>CH7EES<br>CH7EEF<br>—<br>—| ||**CH24EE225R**<br>—<br>—<br>—<br>—| ||**CH30EE**<br>CH7EES<br>CH7EEF<br>CH7EESM<br>CH7EEFM| ||**CH30EER**<br>—<br>—<br>—<br>—| ||**CH30EE225**<br>CH7EES<br>CH7EEF<br>—<br>—| ||**CH30EE225R**<br>—<br>—<br>—<br>—| ||**CH42GG**<br>CH7GGS<br>CH7GGF<br>CH7GGSM<br>CH7GGFM| ||**CH42GGR**<br>—<br>—<br>—<br>—| ||**CH42PL400**<br>CH7PS<br>CH7PF<br>—<br>—| ||**CH48S**<br>—<br>—<br>—<br>—| ||**CH48F**<br>—<br>—<br>—<br>—| ||**CH48R**<br>—<br>—<br>—<br>—| ||**CH816S**<br>—<br>—<br>—<br>—| ||**CH816F**<br>—<br>—<br>—<br>—| ||**CH816R**<br>—<br>—<br>—<br>—| ||**CH1624BB**<br>CH7BBS<br>CH7BBF<br>—<br>—| ||**CH1624BBR**<br>—<br>—<br>—<br>—| ||**CH3042EE225**<br>CH7EES<br>CH7EEF<br>—<br>—| ||**CH3042EE225R**<br>—<br>—<br>—<br>—| ||| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-12** Loadcenters 5 Type CH **5** ## **Three-Phase with Main Lugs** ## **Three-Phase with Main Circuit Breaker** |**Catalog**<br>**Number**<br>**Surface**<br>**Covers**<br>**Flush**<br>**Covers**<br>**Surface Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**Flush Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**CH64S**<br>—<br>—<br>—<br>—<br>**CH64R**<br>—<br>—<br>—<br>—<br>**CH124BB**<br>CH7BBS<br>CH7BBF<br>CH7BBSM<br>CH7BBFM<br>**CH124BBR**<br>—<br>—<br>—<br>—<br>**CH184CC**<br>CH7CCS<br>CH7CCF<br>CH7CCSM<br>CH7CCFM<br>**CH184CCR**<br>—<br>—<br>—<br>—<br>**CH244CC**<br>CH7CCS<br>CH7CCF<br>CH7CCSM<br>CH7CCFM<br>**CH244CCR**<br>—<br>—<br>—<br>—<br>**CH244EE225**<br>CH7EES<br>CH7EEF<br>CH7EESM<br>CH7EEFM<br>**CH244EE225R**<br>—<br>—<br>—<br>—<br>**CH304EE**<br>CH7EES<br>CH7EEF<br>CH7EESM<br>CH7EEFM<br>**CH304EER**<br>—<br>—<br>—<br>—<br>**CH304EE225**<br>CH7EES<br>CH7EEF<br>—<br>—<br>**CH304EE225R**<br>—<br>—<br>—<br>—<br>**CH424GG225**<br>CH7GGS<br>CH7GGF<br>CH7GGSM<br>CH7GGFM<br>**CH424GG225R**<br>—<br>—<br>—<br>—<br>**CH424PL400**<br>CH7PS<br>CH7PF<br>—<br>—|**Catalog**<br>**Number**<br>**Surface**<br>**Covers**<br>**Flush**<br>**Covers**<br>**Surface Covers**<br>**w/ Mechanical**<br>**Interlock**<br>**Flush Covers**<br>**w/ Mechanical**<br>**Interlock**| |---|---| ||**CH304JJM150**<br>CH7JJS<br>CH7JJF<br>—<br>—| ||**CH304JJM150R**<br>—<br>—<br>—<br>—| ||**CH304JJM200**<br>CH7JJS<br>CH7JJF<br>—<br>—| ||**CH304JJM200R**<br>—<br>—<br>—<br>—| ||**CH304LLM225**<br>CH7LLS<br>CH7LLF<br>—<br>—| ||**CH424KKM200**<br>CH7KKS<br>CH7KKF<br>—<br>—| ||**CH424KKM200R**<br>—<br>—<br>—<br>—| ||**CH424LLM225**<br>CH7LLS<br>CH7LLF<br>—<br>—| ||**CH424PM300**<br>CH7PMS<br>CH7PMF<br>—<br>—| ||**CH424PM400**<br>CH7PMS<br>CH7PMF<br>—<br>—| ||**CH304JJM200H**<br>CH7JJS<br>CH7JJF<br>—<br>—| ||**CH304JJM200HR**<br>—<br>—<br>—<br>—| ||**CH424KKM200H**<br>CH7KKS<br>CH7KKF<br>—<br>—| ||**CH424KKM200HR**<br>—<br>—<br>—<br>—| ||**CH424LLM225H**<br>CH7LLS<br>CH7LLF<br>—<br>—| ||| ## **Type CH Loadcenter Interior Assemblies** |**Catalog**|**Ampere**|**Maximum Number 1.00-Inch (25.4 mm)**|**Maximum Number 1.00-Inch (25.4 mm)**|**UL File**|**Main Terminal Wire Size Range**|**Standard**| |---|---|---|---|---|---|---| |**Number**|**Rating**|**Spaces**|**Single-Pole**|**Reference**|**(per phase) Cu/Al 60ºC or 75ºC**|**Package Quantity**| |**Single-Phase,**|**Single-Row**|**Breaker Mounting—Copper Bus 120/24 Vac, Three-Wire**||||| |**CH9MB270**|70|2|2|E8741|(1) #8–#2 AWG Cu/Al|1| |**CH2L125INT**|125|2|2|E8741|(1) 2/0–#6 AWG Cu/Al|20| |**Single-Phase,**|**Double-Row Breaker Mounting—Copper Bus 120/240 Vac, Three-Wire**|||||| |**CH4L125INT**|125|4|4|E8741|(1) 2/0–#14 AWG Cu/Al|20| |**CH8L125INT**|125|8|8|E8741|(1) 2/0–#6 AWG Cu/Al|20| |**CH12L125INT**|125|12|12|E8741|(1) 2/0–#6 AWG Cu/Al|20| |**CH16L125INT**|125|16|16|E8741|(1) 2/0–#6 AWG Cu/Al|20| |**CH12L200INT**|200|12|12|E8741|(1) 300 kcmil–#4 AWG Cu/Al|20| |**CH16L200INT**|200|16|16|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**CH24L225INT**|225|24|24|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**CH32L225INT**|225|32|32|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**CH42L225INT**|225|42|42|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**Three-Phase, Double-Row**||**Breaker Mounting—Copper Bus 208Y/120 Vac, Four-Wire—240**|||**Vac, Three-Wire—120/240 Vac,**|**Four-Wire Delta**| |**CH12L3125INT**|125|12|12|E8741|(1) 2/0–#6 AWG Cu/Al|10| |**CH18L3125INT**|125|18|18|E8741|(1) 2/0–#6 AWG Cu/Al|10| |**CH24L3125INT**|125|24|24|E8741|(1) 2/0–#6 AWG Cu/Al|10| |**CH24L3225INT**|225|24|24|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**CH30L3225INT**|225|30|30|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| |**CH42L3225INT**|225|42|42|E8741|(1) 300 kcmil–#4 AWG Cu/Al|10| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-13** Loadcenters 5 ## Type BR **5** |||**Type BR Replacement Parts and Covers**<br>**Number**<br>**Ampere**<br>**Number of 1.00-Inch (25.4 mm)**|**Type BR Replacement Parts and Covers**<br>**Number**<br>**Ampere**<br>**Number of 1.00-Inch (25.4 mm)**|**Wire Size Range**|**Ordering**||**Catalog**| |---|---|---|---|---|---|---|---| |||**of Poles**<br>**Rating**|**Spaces Needed**|**Cu/Al 60 °C or 75 °C**|**Quantity**|**Quantity**1|**Number**| |**BRSF125**||**Main and Subfeed Lug Blocks**|||||| |||2<br>125|2|#8–2/0|1||**BRSF125**| |**BRSF150**||150|2|#8–2/0|1||**BRSF150**2| |**BRS225**||225|4|#2–300 kcmil|1||**BRS225**| |**3BRSF150**||3<br>150|3|#8–2/0|1||**3BRSF150**2| |**3BRSF225**||225|6|#2–300 kcmil|1||**3BRS225**| |**BRL200**||**Main Lugs**|||||| |**NL20**||Two-pole, 200 A stud mounted (includes deadfront filler plate)<br>Neutral/ground lug||#1–300 kcmil<br>#2/0 maximum|1<br>1||**BRL200**<br>**NL20**| |||Add-on neutral or ground lug|||||| ||||||||| |**NL30**||Neutral/ground lug||#3/0 maximum|1||**NL30**| ||Be|Add-on neutral or ground lug|||||| |Neutral/ground lug<br>Add-on neutral or ground lug<br>300 kcmil maximum<br>1<br>**NL300**<br>**Filler Plates**<br>1.00-inch (25.4 mm) circuit breaker space<br>25<br>**BRFP**<br>**NL300**<br>**BRFP**<br>@201~~Pe~~|||||||| |Saad|**BRFP**<br>Saad|BW main circuit breaker space (with hardware)|||1|**BWFP**<br>~~a~~|| |||**_Notes_**|||||| |||1Must be purchased in multiples of ordering quantities indicated.|||||| |||2#8–2/0 wire size range is 75 °C rated only.|#8–2/0 wire size range is 75 °C rated only.||||| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-14** Loadcenters 5 Type BR ||||**Type BR Replacement Parts and Covers, continued**|**Type BR Replacement Parts and Covers, continued**|||| |---|---|---|---|---|---|---|---| ||||**Number**<br>**Ampere**|**Number of 1.00-Inch (25.4 mm)**|**Wire Size Range**|**Ordering**|**Catalog**| ||||**of Poles**<br>**Rating**|**Spaces Needed**|**Cu/Al 60 °C or 75 °C**|**Quantity**1|**Number**| |**TDL**|||**Filler Plates, continued**||||| ||BE||Door lock —12–42 circuits, and 100–225 A|||1|**TDL**| ||||Door lock—4–8 circuits, 12 5A|||1|**CH9FL**| ||**SPC61**||ANSI-61 light gray touchup paint for current loadcenters|||1|**SPC61**| ||**BINA**||Isolated neutral assembly (computer circuits)|||1|**BINA**| |**TCD**|||Circuit directory—adhesive backed|||10|**TCD**| ||EE||||||| ||**LCCS**||Cover screws|||25|**LCCS**| |**BRRL**|||Cover replacement latch (gray) 14-5/16 (363.5 mm) wide loadcenters only|||1|**BRRL**| |**BRMS**|||Circuit marking strip (next to breaker)|||10|**BRMS**| |**CHBL**|||Circuit identification label (preprinted breaker labels)|||25|**CHBL**| ||=|=3|||||| ||7|———=|||||| |**SRL**|||Series rated caution label|||25|**SRL**| |**BSSUSE**|||Bonding strip with screw|||1|**BSSUSE**| ||||**_Note_**||||| ||||1Must be purchased in multiples of ordering quantities indicated.||||| **5** **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-15** 5 Type BR **5** ~~7~~ ## Loadcenters ## _**Mechanical Interlock Cover**_ Covers mechanically interlock two breakers—Type BW or BWH main breaker with a Type BR branch breaker. |**BR4040B200**|**Mechanical Interlock Covers**|**Mechanical Interlock Covers**| |---|---|---| ||**Fits Loadcenter**<br>**Catalog Number**|**Mechanical Interlock Panel Cover**<br>**Catalog Number**| ||**BR816B200RF**|**BR3RDF5M**| ||**BR2040B200R**|**BR3RDF11M**| ||**BR3040B200R**<br>**BR3RDF12M**<br>**BR4040B200R**<br>**BR3RDF13M**<br>**BR2040B200**<br>**BRCOV20D1FM**<br>~~OO~~|| ||**BR3040B200**|**BRCOV30G1FM**| ||**BR4040B200**|**BRCOV40L1FM**| ## **Replacement Breaker Accessories** ||**Replacement Breaker Accessories**||| |---|---|---|---| ||**Description**|**Ordering**<br>**Quantity**1|**Catalog**<br>**Number**| |**BHT**<br>Ped|**Handle Ties**2<br>Handle tie bar for physically joining the handles of two adjacent single-pole Type BR circuit breakers (metal cylinder pin type)<br>.o~~ooooooOOOOOO~~<br>~~ee~~<br>Ped|10<br>~~ee~~|**BHT**<br>~~ee~~| |**THOW**|Handle tie bar for joining two independent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD<br>duplex circuit breakers|10|**THOW**| |**THS1**<br>~~SF~~|Handle tie bar for joining two adjacent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD duplex circuit breakers<br>~~SF~~|10<br>~~SF~~|**THS1**<br>~~SF~~| |---|---|---|---| |**BRLW**|**Handle Lockoffs**3||| |<|Padlockable device for locking the handle of single-, two- or three-pole Type BR Circuit Breakers and single-pole of a Type BD Duplex<br>or one independent outside pole of a Type BQ or BQC Quadplex circuit breakers (escutcheon mounted)4|10|**BRLW**| |**BRLW1**<br>ry|Padlockable device for locking the handle of a single-pole Type BR circuit breaker.(handle mounted)4|10|**BRLW1**| ||**_Notes_**||| - 1 Must be purchased in multiples of ordering quantities indicated. 2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker. - 3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position. - 4 Handle mounted: device mounted directly to the handle by the use of a set screw. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-16** Loadcenters 5 Type BR ## **Replacement Breaker Accessories, continued** |||**Replacement Breaker Accessories, continued**||| |---|---|---|---|---| ||||**Ordering**|**Catalog**| |||**Description**|**Quantity**1|**Number**| |**BRLW2**||**Handle Lockoffs, continued**2||| ||3|Padlockable device for locking the handle of a two- and three-pole Type BR circuit breaker (handle mounted)3|10|**BRLW2**| |Fg||||| |**BRDL1**||Padlockable device for locking the handle of a single-pole Type BD Duplex, BQ or BQC Quadplex breaker (handle mounted)3|10|**BRDL1**| |**BRQLW**||Padlockable device for locking the handle of the two center poles and the two outer poles of a two-pole Types BQ and BQC quadplex|10|**BRQLW**| |||circuit breakers (escutcheon mounted)4||| ||EE<br>atteum<br>Ft|||| |**CCPL**||Padlockable device for locking the handle of main circuit breaker Types CC and CHH into the ON or OFF position (screw mounted)5|1|**CCPL**| |**MCBPL**||Padlockable device for locking the handle of main breaker Types BW and BWH into the ON or OFF position (escutcheon mounted)4|1|**MCBPL**| |**BHLW**||**Handle Lockdog**6||| |||Device used to secure handle in ON or OFF position for single-, two- or three-pole Type BR circuit breakers and single-pole of Type BD|10|**BHLW**| |||duplex and one independent outside pole of Type BQ or BQC Quadplex circuit breakers (escutcheon mounted)3||| |**BHLW1**||Device used to secure handle in ON or OFF position for single-pole Type BR circuit breakers (handle mounted)3|10|**BHLW1**| |‘em||||| ||**BHLW2**|Device used to secure handle in ON or OFF position for two- and three-pole Type BR circuit breakers (handle mounted)3|10|**BHLW2**| ||as<br>23<br>Bg|||| |||**_Notes_**||| |||1Must be purchased in multiples of ordering quantities indicated.||| |||2Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.||| |||3Handle mounted: device mounted directly to the handle by the use of a set screw.||| **5** - 4 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront. 5 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw. - 6 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle Lockdogs are not padlockable devices. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-17** Loadcenters 5 Type BR **5** ~~mtd~~ **6** ## **Replacement Breaker Accessories, continued** |||**Replacement Breaker Accessories, continued**||| |---|---|---|---|---| ||||**Ordering**|**Catalog**| |||**Description**|**Quantity**1|**Number**| |**BHGW**||**Handle Lockdog, continued**2||| |**HLW1**iW||Device used to secure handle in ON or OFF position for single-pole Type GFCB ground fault circuit breakers (handle mounted)3<br>Device used to secure handle in ON or OFF position for one independent outside pole of Types BQ and BQC Quadplex or single-pole|10<br>10|**BHGW**<br>**HLW1**| |~~mtd~~|~~mtd~~|Type BD duplex circuit breakers (handle mounted)3<br>~~mtd~~||| ||**BRHDB**|**Hold-Down Kits**4||| |||Hold-down retainer kit for three-pole Type BR circuit breakers in S3100 and 3100R loadcenters only|1|**BRHDB**| |**BREQS125**||Hold-down screw kit for two-pole Type BR circuit breakers in single-phase MLO loadcenters through 125 A|1|**BREQS125**| |**BRHDK125**||Hold-down screw kit for two-pole Type BR circuit breakers in MLO loadcenters 150–225 A (single-phase only)|1|**BRHDK125**| |**BJHDS**||Hold-down screw kit for two-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225 A|1|**BJHDS**| |**BJHDS3P**||Hold-down screw kit for three-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225 A|1|**BJHDS3P**| ||I|||| ||**CCL300**|**Main Breaker Lug Kits**||| |**_Notes_**<br>Types CC and CHH main breaker lug kit (2) 300 kcmil<br>1<br>**CCL300**<br>Types BW/BWH main breaker lug kit (2) 300 kcmil<br>1<br>**MCBL300**<br>**Mechanical Interlock**<br>Types BR for two-, three- and four-pole breakers<br>10<br>**BRML**<br>**MCBL300**<br>**BRML**<br>‘8.~~wo~~||||| |||1Must be purchased in multiples of ordering quantities indicated.||| 2 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle Lockdogs are not padlockable devices. - 3 Handle mounted: device mounted directly to the handle by the use of a set screw. - 4 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g). **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** **V12-T5-18** CA08100014E—October 2016 www.eaton.com Loadcenters 5 Type BR **5** ## _**Renewal Parts for Type BR Loadcenter Covers and Deadfronts**_ ## **Single-Phase with Main Circuit Breakers** |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**|**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |---|---|---|---|---|---|---|---|---|---| |**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**|**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**| |**B4242DFN**|315-003-28|—|—|—|**BR2040B150R**|—|—|BR3RDOOR8|BR3RDF11| |**B4242DR1N**|—|—|Not available|—|**BR2040B200**|BRCOVC35|—|—|—| |**B4242DSN**|—|315-003-27|—|—|**BR2040B200R**|—|—|BR3RDOOR9|BR3RDF11| |**B4242EFN**|315-003-28|—|—|—|**BR2040H200**|BRCOVC35|—|—|—| |**B4242ESN**|—|315-003-27|—|—|**BR2430B150**|BRCOVC40|—|—|—| |**BR1020B100RF**|—|—|BR3RDOOR2|BR3RDF1|**BR2440B200**|BRCOVC41|—|—|—| |**BR1212B100**|BRCOVC12|—|—|—|**BR3030BC100**|BRCOVC59|||| |**BR1220B100**|BRCOVC12|—|—|—|**BR3030B150**|BRCOVC40|—|—|—| |**BR1224B100R**||—|BR3RDOOR2|BR3RDF1|**BR3030B150R**|—|—|BR3RDOOR10|BR3RDF12| |**BR1224B100SFG**|47-37466|||47-37469|**BR3030BC150**|BRCOVC40|—|—|—| |**BR1616B100**|BRCOVC16|—|—|—|**BR3040B150**|BRCOVC40|—|—|—| |**BR1620B100**|BRCOVC16|—|—|—|**BR3040B200**|BRCOVC41|—|—|—| |**BR1624B100**|BRCOVC16|—|—|—|**BR3040B200R**|—|—|BR3RDOOR11|BR3RDF12| |**BR1624B100R**|—|—|BR3RDOOR3|BR3RDF2|**BR3040H200**|BRCOVC41|—|—|—| |**BR1624B125**|BRCOVC17|—|—|—|**BR304242F**|315-003-28|—|—|—| |**BR1630B150**|BRCOVC29|—|—|—|**BR304242S**|—|315-003-27|—|—| |**BR1632B200**|BRCOVC31|—|—|—|**BR4040B200**|BRCOVC44|—|—|—| |**BR2020B100**|BRCOVC22|—|—|—|**BR4040BC200**|BRCOVC44|—|—|—| |**BR2024B100R**|—|—|BR3RDOOR4|BR3RDF4|**BR4040B200R**|—|—|BR3RDOOR12|BR3RDF13| |**BR2024B125**|BRCOVC23|—|—|—|**BR4040H200**|BRCOVC44|—|—|—| |**BR2024B125R**|—|—|BR3RDOOR4|BR3RDF4|**BR4242B225**|BRCOVC53 (2)|—|—|—| |**BR2024H100**|BRCOVC22|—|—|—|**BR4242B225R**|—|—|BR3RDOOR13|BR3RDF15| |**BR2030B150**|BRCOVC32|—|—|—|**BR48B200RF**|—|—|BR3RDOOR15|BR3RDF14| |**BR2030B150R**|—|—|BR3RDOOR8|BR3RDF11|**BR816B100**|BRCOVC10|—|—|—| |**BR2030H150**|BRCOVC32|—|—|—|**BR816B150RF**|—|—|BR3RDOOR5|BR3RDF5| |**BR2040B150**|BRCOVC40|—|—|—|**BR816B200RF**|—|—|BR3RDOOR6|BR3RDF5| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-19** 5 ## Loadcenters ## Type BR **5** ## **Convertible** |**Convertible**||||| |---|---|---|---|---| |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**| |**3BR1224N125**|BRCOVC20|—|—|—| |**3BR1224N125R**|—|—|BR3RDOOR29|BR3RDF2| |**3BR1224N125S**|—|BRCOVS20|—|—| |**3BR3030N100**|BRCOVC37|—|—|—| |**3BR3030N100R**|—|—|BR3RDOOR30|—| |**3BR3030N100S**|—|BRCOVS37|—|—| |**BR1224N125**|BRCOVC13|—|—|—| |**BR1224N125R**|—|—|BR3RDOOR2|BR3RDF1| |**BR1224NC125R**|||BR3RDOOR2|| |**BR1224N200**|BRCOVC30|—|—|—| |**BR1224N200R**|—|—|BR3RDOOR6|BR3RDF5| |**BR1624N125**|BRCOVC17|—|—|—| |**BR1624N125R**|—|—|BR3RDOOR3|BR3RDF2| |**BR1632N200**|BRCOVC31|—|—|—| |**BR1632N200SFG**|||47-37460|47-37375| |**BR2024N125**|BRCOVC23|—|—|—| |**BR2024N125R**|—|—|BR3RDOOR4|BR3RDF4| |**BR2040N200**|BRCOVC35|—|—|—| |**BR2040N200R**<br>**BR2440N200**|—<br>BRCOVC41|—<br>—|BR3RDOOR9<br>—|BR3RDF11<br>—| |**BR3040N200**<br>**BR3040N200R**|BRCOVC41<br>—|—<br>—|—<br>BR3RDOOR11|—<br>BR3RDF12| |**BR4040N200**<br>**BR4040N200R**|BRCOVC44<br>—|—<br>—|—<br>BR3RDOOR12|—<br>BR3RDF13| |**BR816N200RF**<br>**BR4040NL200G**|—<br>BRCOVC44 + BWFP|—<br>—|BR3RDOOR6<br>—|BR3RDF5<br>—| ## **Manufactured Housing Loadcenters Single-Phase with Main Circuit Breaker** |**Catalog**|**Cover**|| |---|---|---| |**Number**|**Number**|| |**BR1020B100GK**|MBCOVC10|| |**BR1020B100PK**|MBCOVC10|| |**BR1220B100GK**|MBCOVC11|| |**BR1220B100PK**|MBCOVC11|| |**BR1224B100PK**|MBCOVC24|| |**BR1224B100GK**|MBCOVC24|| |**BR1224B100GK**|MBCOVC25|1| |**BR1224B150GK**|MBCOVC12|| |**BR1224B150PK**|MBCOVC12|| |**BR1630B150GK**|MBCOVC13|| |**BR1630B150PK**|MBCOVC13|| |**BR1224B200GK**|MBCOVC14|| |**BR1224B200PK**|MBCOVC14|| |**BR1632B200GK**|MBCOVC15|| |**BR1632B200PK**|MBCOVC15|| |**BR2040B200GK**|MBCOVC16|| |**BR2040B200PK**|MBCOVC16|| |**BR1020B100PKW**|MBCOVC17|1| |**BR1220B100PKW**|MBCOVC18|1| |**BR1224B100PKW**|MBCOVC25|1| |**BR1224B150PKW**|MBCOVC19|1| |**BR1630B150PKW**|MBCOVC20|1| |**BR1224B200PKW**|MBCOVC21|1| |**BR1632B200PKW**|MBCOVC22|1| |**BR2040B200PKW**|MBCOVC23|1| ## _**Note**_ > 1 These covers are painted white (standard color is gray). **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-20** Loadcenters 5 Type BR **5** **Single-Phase with Main Lugs** |**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**|**Catalog**|**Combination**|**Surface**|**NEMA 3R**|**NEMA 3R**| |---|---|---|---|---|---|---|---|---|---| |**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**|**Number**|**Covers**|**Covers**|**Covers**|**Deadfronts**| |**1224DRIN**|—|—|Not available|—|**BR24L70RP**|—|—|Not available|—| |**1224DSN**|—|Not available|—|—|**BR24L70SGP**|—|Not available|—|—| |**2442DSN**|—|Not available|—|—|**BR24L70SP**|—|Not available|—|—| |**2460FGNM**|—|—|—|—|**BR1224L125RIS**|BRCOVC66|||| |**2460FNM**|—|—|—|—|**BR1224L125RISBP**|BRCOVC66|||| |**2460RNM**|—|—|—|—|**BR2024L125RIS**|BRCOVC66|||| |**2460SGNM**|—|—|—|—|**BR3040L200**|BRCOVC36|—|—|—| |**2460SNM**|—|—|—|—|**BR3040L200G**|BRCOVC36|—|—|—| |**4242DFN**|315-003-06|—|—|—|**BR3040L200R**|—|—|BR3RDOOR9|BR3RDF8| |**4242DRIN**|—|Not available|—|—|**BR4040L200**|BRCOVC42|—|—|—| |**4242DSN**|—|315-003-05|—|—|**BR4040L200R**|—|—|BR3RDOOR11|BR3RDF9| |**4242ESN**|—|315-003-05|—|—|**BR4242L225**|BRCOVC45|—|—|—| |**BR1212L125**|BRCOVC11|—|—|—|**BR4242L225R**|—|—|BR3RDOOR14|BR3RDF10| |**BR1224L125**|BRCOVC11|—|—|—|**BR48L125FDP**|BRCOVC62 (flush)|—|—|—| |**BR1224L125DG**|BRCOVC11|—|—|—|**BR48L125FGP**|BRCOVC63 (flush)|—|—|—| |**BR1224L125G**|BRCOVC11|—|—|—|**BR48L125FP**|BRCOVC61 (flush)|—|—|—| |**BR1224L125R**|—|—|BR3RDOOR1|BR3RDF3|**BR48L125RP**|—|—|BR3RDOOR26|BR3RDF22| |**BR1224L200**|BRCOVC15|—|—|—|**BR48L125SGP**|—|BRCOVS60|—|—| |**BR1224L200R**|—|—|BR3RDOOR7|BR3RDF6|**BR48L125SP**|—|BRCOVS59|—|—| |**BR1616L125**|BRCOVC14|—|—|—|**BR612L125FDGP**|BRCOVC08|—|—|—| |**BR1624L125**|BRCOVC14|—|—|—|**BR612L125FDP**|BRCOVC08|—|—|—| |**BR1624L125G**|BRCOVC14|—|—|—|**BR612L125FGP**|BRCOVC63|—|—|—| |**BR1624L125R**|—|—|BR3RDOOR2|BR3RDF1|**BR612L125FP**|BRCOVC08|—|—|—| |**BR1630L150**|BRCOVC25|—|—|—|**BR612L125RP**|—|—|BR3RDOOR27|BR3RDF23| |**BR2020L125**|BRCOVC18|—|—|—|**BR612L125SDGP**|—|BRCOVS08|—|—| |**BR2024L125**|BRCOVC18|—|—|—|**BR612L125SDP**|—|BRCOVS08|—|—| |**BR2024L125G**|BRCOVC18|—|—|—|**BR612L125SGP**|—|BRCOVS60|—|—| |**BR2024L125R**|—|—|BR3RDOOR3|BR3RDF2|**BR612L125SP**|—|BRCOVS59|—|—| |**BR2030L150**|BRCOVC25|—|—|—|**BR816L125FDGP**|BRCOVC64 (flush)|—|—|—| |**BR2040L200**|BRCOVC25|—|—|—|**BR816L125FDP**|BRCOVC64 (flush)|—|—|—| |**BR2040L200G**|BRCOVC25|—|—|—|**BR816L125FGP**|BRCOVC09|—|—|—| |**BR2040L200R**|—|—|BR3RDOOR6|BR3RDF7|**BR816L125FP**|BRCOVC09|—|—|—| |**BR2424L125**|BRCOVC24|—|—|—|**BR816L125RP**|||BR3RDOOR28|BR3RDF23| |**BR2424L125G**|BRCOVC24|—|—|—|**BR816L125SDGP**||BRCOVS61|—|—| |**BR2440L200**|BRCOVC33|—|—|—|**BR816L125SDP**|—|BRCOVS61|—|—| |**BR24L125FP**|BRCOVC60 (FLUSH)|—|—|—|**BR816L125SGP**||BRCOVS09|—|—| |**BR24L125RP**|—|—|BR3RDOOR25|BR3RDF21|**BR816L125SP**||BRCOVS09|—|—| |**BR24L125RSE2P**|—|—|—|BR3RDF21|**BR816L200RF**|—|—|BR3RDOOR7|BR3RDF6| |**BR24L125RSEP**|—|—|—|BR3RDF21|**BR816LC125FDP**|BRCOVC64 (flush)|—|—|—| |**BR24L125SP**|—|BRCOVS62|—|—|**TT120FLGNM**|—|—|—|—| |**BR24L70FGP**|Not available|—|—|—|**TT120SLGNM**|—|—|—|—| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-21** Loadcenters 5 **5** ## Type BR ## **Three-Phase with Main Lugs** ## **Three-Phase with Main Circuit Breaker** |**Catalog**<br>**Number**<br>**Combination**<br>**Covers**<br>**Surface**<br>**Covers**<br>**NEMA 3R**<br>**Covers**<br>**NEMA 3R**<br>**Deadfronts**<br>**31836DFN**<br>Not available<br>—<br>—<br>—<br>**31836DR1N**<br>—<br>—<br>Not available<br>—<br>**31836DSN**<br>—<br>Not available<br>—<br>—<br>**32442DSN**<br>—<br>Not available<br>—<br>—<br>**34242DFN**<br>315-003-06<br>—<br>—<br>—<br>**34242DR1N**<br>—<br>—<br>Not available<br>—<br>**34242DSN**<br>—<br>315-003-05<br>—<br>—<br>**34242EFN**<br>315-003-06<br>—<br>—<br>—<br>**34242ESN**<br>—<br>315-003-05<br>—<br>—<br>**3BR1224L125**<br>BRCOVC21<br>—<br>—<br>—<br>**3BR1224L125R**<br>—<br>—<br>BR3RDOOR29<br>BR3RDF2<br>**3BR1224L125S**<br>—<br>BRCOVS21<br>—<br>—<br>**3BR1224L200**<br>BRCOVC34<br>—<br>—<br>—<br>**3BR1224L200R**<br>—<br>—<br>BR3RDOOR16<br>BR3RDF7<br>**3BR1224L200S**<br>—<br>BRCOVS34<br>—<br>—<br>**3BR1836L150**<br>BRCOVC27<br>—<br>—<br>—<br>**3BR1836L150R**<br>—<br>—<br>BR3RDOOR17<br>BR3RDF7<br>**3BR1836L150S**<br>—<br>BRCOVS27<br>—<br>—<br>**3BR1836L200**<br>BRCOVC34<br>—<br>—<br>—<br>**3BR1836L200R**<br>—<br>—<br>BR3RDOOR16<br>BR3RDF7<br>**3BR1836L200S**<br>—<br>BRCOVS34<br>—<br>—<br>**3BR2442L150**<br>BRCOVC39<br>—<br>—<br>—<br>**3BR2442L150R**<br>—<br>—<br>BR3RDOO18<br>BR3RDF16<br>**3BR2442L150S**<br>—<br>BRCOVS39<br>—<br>—<br>**3BR2442L200**<br>BRCOVC43<br>—<br>—<br>—<br>**3BR2442L200S**<br>—-<br>BRCOVS43<br>—<br>—<br>**3BR3042L200**<br>BRCOVC43<br>—<br>—<br>—<br>**3BR3042L200R**<br>—<br>—<br>BR3RDOO19<br>BR3RDF18<br>**3BR3042L200S**<br>—<br>BRCOVS43<br>—<br>—<br>**3BR4242L200**<br>BRCOVC48<br>—<br>—<br>—<br>**3BR4242L200R**<br>—<br>—<br>BR3RDOOR21<br>BR3RDF20<br>**3BR4242L200S**<br>—<br>BRCOVS48<br>—<br>—<br>**3BR4242L225**<br>BRCOVC49<br>—<br>—<br>—<br>**3BR4242L225R**<br>—<br>—<br>BR3RDOOR24<br>BR3RDF20<br>**3BR4242L225S**<br>—<br>BRCOVS49<br>—<br>—|**Catalog**<br>**Number**<br>**Combination**<br>**Covers**<br>**Surface**<br>**Covers**<br>**NEMA 3R**<br>**Covers**<br>**NEMA 3R**<br>**Deadfronts**| |---|---| ||**3B4242DFN**<br>315-003-28<br>—<br>—<br>—| ||**3B4242DR1N**<br>—<br>—<br>Not available<br>—| ||**3B4242DSN**<br>—<br>315-003-27<br>—<br>—| ||**3B4242EFN**<br>315-003-28<br>—<br>—<br>—| ||**3B4242ESN**<br>—<br>315-003-27<br>—<br>—| ||**3BR1224B100**<br>BRCOVC19<br>—<br>—<br>—| ||**3BR1224B100R**<br>—<br>—<br>BR3RDOOR29<br>BR3RDF2| ||**3BR1224B100S**<br>—<br>BRCOVS19<br>—<br>—| ||**3BR1224H100**<br>BRCOVC19<br>—<br>—<br>—| ||**3BR1224H100S**<br>—<br>BRCOVS19<br>—<br>—| ||**3BR3042B125**<br>BRCOVC54<br>—<br>—<br>—| ||**3BR3042B125S**<br>—<br>BRCOVS54<br>—<br>—| ||**3BR3042B150**<br>BRCOVC55<br>—<br>—<br>—| ||**3BR3042B150R**<br>—<br>—<br>BR3RDOOR20<br>BR3RDF17| ||**3BR3042B150S**<br>—<br>BRCOVS55<br>—<br>—| ||**3BR3042B200**<br>BRCOVC56<br>—<br>—<br>—| ||**3BR3042B200R**<br>—<br>—<br>BR3RDOOR21<br>BR3RDF17| ||**3BR3042B200S**<br>—<br>BRCOVS56<br>—<br>—| ||**3BR3042H150**<br>BRCOVC55<br>—<br>—<br>—| ||**3BR3042H150S**<br>—<br>BRCOVS55<br>—<br>—| ||**3BR3042H200**<br>BRCOVC56<br>—<br>—<br>—| ||**3BR3042H200S**<br>—<br>BRCOVS56<br>—<br>—| ||**3BR4242B200**<br>BRCOVC57<br>—<br>—<br>—| ||**3BR4242B200R**<br>—<br>—<br>BR3RDOOR22<br>BR3RDF19| ||**3BR4242B200S**<br>—<br>BRCOVS57<br>—<br>—| ||**3BR4242B225**<br>BRCOVC58<br>—<br>—<br>—| ||**3BR4242B225R**<br>—<br>—<br>BR3RDOOR23<br>BR3RDF19| ||**3BR4242B225S**<br>—<br>BRCOVS58<br>—<br>—| ||**3BR4242H200**<br>BRCOVC57<br>—<br>—<br>—| ||**3BR4242H200S**<br>—<br>BRCOVS57<br>—<br>—| ||| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-22** Loadcenters 5 Type BR ## **Replacement Interior Assembly** ## **Type BR Loadcenter Interior Assemblies** ## **BR Loadcenter Interior Assembly** |**BR Loadcenter**<br>**Interior Assembly**|**Type BR Loadcenter Interior Assemblies**|**Type BR Loadcenter Interior Assemblies**|**Type BR Loadcenter Interior Assemblies**||||| |---|---|---|---|---|---|---|---| |**Interior Assembly**|**Ampere**|**Maximum Number 1.00-Inch (25.4 mm)**|**Maximum Number 1.00-Inch (25.4 mm)**|**UL File**|**Main Terminal Size**|**Standard**|**Catalog**| ||**Rating**|**Spaces**|**Single Poles**|**Reference**|**(Per Phase)**|**Package Quantity**|**Number**| ||**Single-Phase Single Row Breaker Mounting—Aluminum Bus—120/240 Vac, Three-Wire**||||||| ||70|2|4|—|(1) #8–#2 AWG Cu/Al|20|**24INT70B**| |125<br>2<br>4<br>E8741<br>(1) 1/0–#14 AWG Cu<br>2/0–12 AWG All<br>20<br>**24INT125B**<br>125<br>6<br>12<br>E52977<br>(1) 2/0–#14 AWG Cu/Al<br>20<br>**612INT125SRB**<br>**Single-Phase Double Row Breaker Mounting—Aluminum Bus—120/240 Vac, Three-Wire**<br>~~(ee~~<br>_|||||||| ||125|4|8|E8741|(1) 2/0–#14 AWG Cu/Al|20|**48INT125B**| ||125|6|12|E8741|(1) 2/0–#14 AWG Cu/Al|20|**612INT125B**| ||125|8|16|E8741|(1) 2/0–#14 AWG Cu/Al|20|**816INT125B**| ||125|12|12|E52977|(1) 2/0–#14 AWG Cu/Al|20|**1212INT125B**| ||125|12|24|E52977|(1) 2/0–#14 AWG Cu/Al|20|**1224INT125B**| ||125|16|24|E52977|(1) 2/0–#14 AWG Cu/Al|20|**1624INT125B**| ||125|20|24|E52977|(1) 2/0–#14 AWG Cu/Al|10|**2024INT125B**| ||125|24|24|E52977|(1) 2/0–#14 AWG Cu/Al|10|**2424INT125B**| ||200|8|16|E52977|(1) 300 kcmil–#1 AWG Cu/Al|20|**816INT200B**| ||200|12|24|E52977|(1) 300 kcmil–#1 AWG Cu/Al|20|**1224INT200B**| ||200|30|40|E52977|(1) 300 kcmil–#1 AWG Cu/Al|10|**3040INT200B**| ||200|42|42|E52977|(1) 300 kcmil–#1 AWG Cu/Al|10|**4242INT225B**| ||**Single-Phase Double Row Breaker Mounting—Copper Bus—120/240 Vac, Three-Wire**||||||| ||125|8|16|E5297|(1) 2/0–#14 AWG Cu/Al|20|**816INT125BC**| ||125|12|12|E5297|(1) 2/0–#14 AWG Cu/Al|20|**1212INT125BC**| ||200|12|24|E5297|(1) 300 kcmil–#1 AWG Cu/Al|20|**1224INT200BC**| ||**Three-Phase Double Row Breaker Mounting—Aluminum Bus—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—**||||||| ||**120/240 Vac, Four-Wire Delta**|**120/240 Vac, Four-Wire Delta**|||||| ||125|12|34|E52977|(1) 2/0–#8 AWG Cu/Al|10|**1224INT3125B**| ||150|18|36|E52977|(1) 300 kcmil–#2 AWG Cu/Al|10|**1836INT3150B**| ||150|24|42|E52977|(1) 300 kcmil–#2 AWG Cu/Al|10|**2442INT3150B**| ||200|30|42|E52977|(1) 300 kcmil–#2 AWG Cu/Al|10|**3042INT3200B**| ||225|42|42|E52977|(1) 300 kcmil–#2 AWG Cu/Al|10|**4242INT3225B**| ||**Three-Phase Double Row Breaker Mounting—Copper Bus—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—**|**Three-Phase Double Row Breaker Mounting—Copper Bus—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—**|||||| ||**120/240 Vac, Four-Wire Delta**<br>125|**120/240 Vac, Four-Wire Delta**<br>12|24|E52977|(1) 2/0–#8 AWG Cu/Al|10|**1224INT3125BC**| ||200|12|24|E52977|(1) 300 kcmil–#2 AWG Cu/Al|10|**1224INT3200BC**| **5** **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-23** Loadcenters 5 Replacement Breakers **5** ## **Product Description** Eaton UL classified replacement circuit breakers are available in both 3/4-inch Type CHQ and 1.00-inch Type CL, single- and two-pole configurations. These breakers are classified as direct replacements by Underwriters Laboratories. In addition to a UL listing, they also come with a 15-year warranty. ## **Specified vs. UL Classified** Specified breakers are listed by the manufacturer of the panelboard for use in a particular panel. This doesn’t mean that the panelboard manufacturer produced the specified breaker; it merely means that the panelboard manufacturer has tested the breaker in the panel. In fact, through the years, Eaton has manufactured thousands of breakers for other panelboard manufacturers. UL classified breakers are produced by one manufacturer for use in place of the breakers specified on the panelboard. Like specified breakers, UL classified breakers have been tested in the panels for which they are approved. ## **Testing** Classified breakers are tested extensively in numerous General Electric[®] , Siemens[®] , Murray[®] , Thomas & Betts[®] , Square D[®] and CrouseHinds[®] panels. The tests are conducted with witnesses from Underwriters Laboratories and involve short circuit, temperature and insertion/withdrawal applications. This level of testing ensures that the breakers meet identified standards and have been found suitable by UL for the specified purpose. ## **Understanding Classified Breaker Terminology** _**Definitions**_ — **Specified Circuit Breaker** Each manufacturer lists the brands of circuit breakers that can be used in their panelboards. Often, manufacturers will not list competitors as specified, even though they are suitable replacements. ## **Classified Circuit Breaker** — A breaker that is considered suitable, by a qualified thirdparty organization, for use in another manufacturer’s panelboard. **Listed Breaker** —The listing of a circuit breaker is by an independent third party. Eaton classified breakers are listed by UL. **Labeled Breaker** —A breaker with a label affixed by an independent third party. ## _**Non-CTL Plug-On Replacement Circuit Breakers, Type CHNT 10 kAIC, 120/240 Vac**_ For use as replacement in loadcenters built prior to 1968 and within the current style loadcenters as indicated in the loadcenter section. ## **3/4-Inch (19.1 mm) per Pole 120 Vac, Non-CTL 10 kAIC** |||**Single-Pole Requires**<br>**One 3/4-Inch (19.1 mm) Space**|**Single-Pole Requires**<br>**One 3/4-Inch (19.1 mm) Space**| |---|---|---|---| |||**10 per Shelf Carton**|| |**Ampere**<br>**Rating**<br>**Wire Size Range**<br>**Cu/Al 60ºC or 75°C**<br>**Catalog Number**<br>15–15<br>#14–8<br>**CHNT1515**12<br>120/240 Vac<br>120/240 Vac<br>~~=~~|||| |15–20|#14–8|**CHNT1520**12|| |20–20|#14–8|**CHNT2020**12|| ## _**CTL Plug-On Circuit Breakers, Type CHT Twin 10 kAIC, 120/240 Vac**_ All circuit breakers have rejection feature. Use only with loadcenters marked for use with CHT breakers. ## **Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC** |**Type CH and CHT**|**Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC**|**Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC**|**Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC**| |---|---|---|---| |**Circuit Breakers**<br>**Mounted in Twin**<br>**Breaker Panel**|||**Single-Pole Requires**<br>**One 3/4-Inch (19.1 mm) Space**| ||||**10 per Shelf Carton**| ||||**Catalog Number**| ||**Ampere**<br>**Rating**|**Wire Size Range**<br>**Cu/Al 60ºC or 75°C**|120/240 Vac<br>120/240 Vac| ||15–15|#14–8|**CHT1515**12| ||15–20|#14–8|**CHT1520**12| ||20–20|#14–8|**CHT2020**12| ## _**Notes**_ 1 Switching duty rated. 2 HACR rated. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-24** Loadcenters 5 Type CH ## **Type CH Renovation Loadcenter** ## **Product Description** Eaton’s Renovation Loadcenter is designed for the service contractor. With the addition of a fivecircuit terminal block factory mounted in the top left corner of the loadcenter, the service contractor can terminate short-circuit wires instead of having to use expensive wire nuts. Also, the Renovation Loadcenter incorporates a twin-stacked neutral design that places the neutral and ground terminations higher in the loadcenter. Both of these features were added without increasing any size from a standard loadcenter. These features will eliminate the need for wire nuts and make for a much neater installation. There is a provision to field mount a second five-circuit terminal block (RN5TB) in the top right corner of the loadcenter. Choose amongst Eaton’s Type CH breaker family for use in the Renovation Panel. **5** ## **Product Selection** ## _**Renewal Parts List for Type CH Renovation Loadcenter Covers and Deadfronts**_ **Renovation Panel Single-Phase, Three-Wire—120/240 Vac—Factory-Bonded Stacked Split Neutral** |||**Max.**|||||**Cover**| |---|---|---|---|---|---|---|---| |||**Number**|||**Wire Size**||**Catalog Number**2| |**Main**|**Main**|**3/4-Inch**|||**Range Cu/Al**|**Loadcenter**|| |**Breaker**|**Ampere**|**(19.1 mm)**|**Enclosure**|**Box**|**60 or 70ºC for**|**Catalog**|| |**Type**|**Rating**|**of Poles**|**Type**|**Size**|**Main Breakers**|**Number**|**Combination Surface**| |CH<br>100<br>20<br>Indoor<br>C<br>#6–1/0<br>**CH22B100CRN**<br>**CH8CFF**<br>**CH8CS**<br>CSH<br>150<br>32<br>Indoor<br>J<br>#2–300 kcmil<br>**CH32B150JRN**<br>**CH8JF**<br>**CH8JS**<br>CSH<br>200<br>32<br>Indoor<br>J<br>#2–300 kcmil<br>**CH32B200JRN**<br>**CH8J**<br>**CH8JS**<br>—~~———————~~|||||||| |CSH|200|42|Indoor|K|#2–300 kcmil|**CH42B200KRN**|**CH8KF**<br>**CH8KS**| ## _**Branch Circuit Breakers (CH)**_ See Volume 1—Residential and Light Commercial, CA08100002E, Tab 1. ## **Renovation Loadcenter** |**Renovation Loadcenter**|| |---|---| |**Description**|**Catalog Number**| |Five-circuit terminal block kit|**RN5TB**| |Ground bar kits (two maximum per panel)|(See**Page** **V12-T5-4**)| ## _**Notes**_ > 1 100A main breaker is rated 10 kAIC. > 2 Combination style covers may be used in surface or flush applications. All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-25** 5 **5** ~~|~~ ## Loadcenters ## Type CH ## **Plug-On Neutral Loadcenter** ## **Product Description** Code changes and higher safety standards are leading to more arc fault and ground fault circuit interrupter installations. Eaton offers a unique product solution that enables a direct connection of the breaker to the neutral bar, eliminating the need for wiring a pigtail. ## **Features and Benefits** - Time savings up to 25% per AFCI/GFCI installation - Eliminates nuisance tripping due to loose pigtail connections - Clean gutter space - Easier troubleshooting due to less wiring - Backed by a limited lifetime warranty ## **Product Selection** **Plug-On Neutral Loadcenter** ## **Main Breaker Plug-On Neutral Loadcenters** |||**Max.**||||||**Cover**|| |---|---|---|---|---|---|---|---|---|---| |**Main**|**Main**|**Number**|**Max.**|||||**Catalog Number**|| |**Breaker**<br>**Type**|**Ampere**<br>**Rating**|**3/4-Inch**<br>**Circuits**|**Number**<br>**of Poles**|**Enclosure**<br>**Type**|**Box**<br>**Size**|**Wire Size**<br>**Range Cu/Al**|**Catalog**<br>**Number**|**Combination**|**Surface**| |CSH 35|100|24|24|Indoor|E|#2–300 kcmil|**CH24BPN100E**|**CH8EF**|**CH8ES**| |kAIC|200|32|32|Indoor|J|#2–300 kcmil|**CH32BPN200J**|**CH8JF**|**CH8JS**| ||200|42|42|Indoor|K|#2–300 kcmil|**CH42BPN200K**|**CH8KF**|**CH8KS**| ||200|60|1201|Indoor|N|#2–300 kcmil|**CH60BPN200N**|**CH8NF**|**—**| ## **Main Lug Only/Convertible Plug-On Neutral Loadcenters—With Factory Installed Main Lugs** ||**Max.**||||||**Wire Size**|**Cover**|| |---|---|---|---|---|---|---|---|---|---| |**Max.**|**Number**||||**Wire Size**|**Main**|**Range**|**Catalog Number**|**Catalog Number**| |**Ampere**|**3/4-Inch**|**Enclosure**|**Box**|**Catalog**|**Range for**|**Breaker**|**For Main**||| |**Rating**|**Poles**|**Type**|**Size**|**Number**|**Main Lug**|**Kit**|**Breaker**|**Combination**|**Surface**| |125|24|Indoor|E|**CH24NLPN125E**|#6–300 kcmil|**CSH2100N**|#2–300 kcmil|**CH8NLEF**|**CH8NLES**| |||||||**CSH2125N**|||| |225|32|Indoor|J|**CH32NLPN225J**|#6–300 kcmil|**CSH2125N**|#2–300 kcmil|**CH8NLJF**|**CH8NLJS**| |||||||**CSH2200N**|||| |||||||**CSH2100N**|||| |225|42|Indoor|K|**CH42NLPN225K**|#6–300 kcmil|**CSH2125N**|#2–300 kcmil|**CH8NLKF**|**CH8NLKS**| |||||||**CSH2150N**|||| |||||||**CSH2200N**|||| ## _**Note**_ 1 Requires the use of type CHNT breakers. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-26** Loadcenters 5 Type CH ## **Type CH Retrofit Interior Kits** _**Type CH Retrofit Adjustable Interior**_ ## **Features and Benefits** _**Upgrading Existing Electrical Infrastructure is Simple**_ - Replaces vintage brands that have hard to find, expensive replacement breakers - Allows safety upgrade to arc fault and ground fault breakers - Maximizes number of circuits available with compact design - Meets 2008 NEC wire bending requirements - Eco-friendly in asbestosfilled environments - Exclusive design ## _**Save Time and Money Throughout the Installation**_ ## **Standards and Certifications** Interiors are UL Recognized under UL 67, Panelboard standard. ## **Product Selection** To select the retrofit kit: 1. From the existing box size determine which retrofit groups are suitable (may be more than one). 2. Use type of interior, number of phases, and type of main to find the selection chart. ## **Retro Size Groups** 3. Select part number from chart (if main breaker, replace XXX with specific amp rating). 4. Note that the overlap of the existing wall is the retro cover size **3** minus the existing box size. If specific **4** measurements are needed, communicate that you need a custom **5** trim size. 5. Contact the Lincoln Flex Center at 800-330-6479 for pricing, lead-times and order entry instructions. - Uses existing panel box and wires - Eliminates expensive drywall/paint repair _**Type CH Retrofit Interior Collar and Assembly with Trim**_ ## **Product Description** Replacing existing loadcenters and panelboards can be a time consuming and expensive job. CH retrofit kits can be the solution to save time and money. The kit consists of a standard trim to fit the interior, a picture frame trim to fit the existing box, and a field-adjustable interior assembly that includes neutral and ground bars. These are especially applicable when the existing box is flush mounted in drywall, plaster or block wall. The existing box, and many times existing wiring, can remain. - Saves 2–3 hours compared to a complete panel changeout—get off the job faster - Eliminates precise measurements with field-adjustable kit ## _**Detailed Product Guide**_ All standard retrofit kits are suitable for a range of existing box sizes: - Box width ranging from 14.50 to 22.00 inches (368.3 to 558.8 mm) - Box depth ranging from 4.25 inches (108.0 mm) for CH to 6.00 inches (152.4 mm) - Box height ranging from 21.00 to 45.00 inches (533.4 to 1143.0 mm) For box dimensions outside of these ranges, contact the Lincoln Flex Center at 800-330-6479. Be sure to provide the existing incoming line wire size. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-27** 5 ## Loadcenters ## Type CH ## **Retrofit Stocking Kits (BR and CH Kits Available)**[12] Five recommended groups: existing box height determines retro group size. **5** ||**Retrofit**<br>**Kit Interior**|**Collar**<br>**Catalog**|**Cover**<br>**Catalog**|**Existing Enclosure**|**Parameters—Inches (mm)**|**Parameters—Inches (mm)**|**Existing Box Height**<br>**Determines Retro**| |---|---|---|---|---|---|---|---| |**Description**|**Catalog Number**|**Number**|**Number**|**Height**|**Width**|**Depth**|**Size Group—Inches (mm)**| |**BR-Aluminum Bus/CH-Copper**|**Bus**||||||| |BR 125A MLO 12/24 circuit retro kit|**RAABR12L125**|Included|Included|14.00–18.00|10.50–12.50|3.50–5.25|Retro size AA/size| |||||(355.6–457.2)|(266.7–317.5)|(88.9–133.35)|14.00–21.00 (355.6–533.4)| |BR 100A MCB 10/20 circuit retro kit|**RAABR10B100**|Included|Included|14.00–18.00|10.50–12.50|3.50–5.25|Retro size AA/size| |||||(355.6–457.2)|(266.7–317.5)|(88.9–133.35)|14.00–21.00 (355.6–533.4)| |BR 125A MLO 12/24 circuit retro kit|**RAABR12L125A**|Included|Included|14.00–21.00<br>(355.6–533.4)|10.50–15.50<br>(266.7–393.7)|3.50–5.25<br>(88.9–133.35)|Retro size AA/size<br>14.00–21.00 (355.6–533.4)| |BR 100A MCB 10/20 circuit retro kit|**RAABR10B100A**|Included|Included|14.00–21.00<br>(355.6–533.4)|10.50–15.50<br>(266.7–393.7)|3.50–5.25<br>(88.9–133.35)|Retro size AA/size<br>14.00–21.00 (355.6–533.4)| |CH interior 125A MCB 22 circuits|**RACH22B125I**|**RACHFRAME**|**CH8CF**|21.00–30.00|13.00–22.00|4.25–6.00|Retro size A/size| |||||(533.4–762.0)|(330.2–558.8)|(108.0–152.4)|21.00–30.00 (533.4–762.0)| |CH interior 125A MLO 24 circuits|**RACH24L125I**|**RACHFRAME**|**CH8CF**|21.00–30.00|13.00–22.00|4.25–6.00|Retro size A/size| |||||(533.4–762.0)|(330.2–558.8)|(108.0–152.4)|21.00–30.00 (533.4–762.0)| |CH interior 150A MCB 24 circuits|**RBCH24B150I**|**RACHFRAME**|**CH8EF**|29.00–36.00|13.00–22.00|4.25–6.00|Retro size B/size| |||||(736.6–914.4)|(330.2–558.8)|(108.0–152.4)|29.00–36.00 (736.6–914.4)| |CH interior 225A MLO 32 circuits|**RBCH32L225I**|**RACHFRAME**|**CH8DF**|29.00–36.00<br>(736.6–914.4)|13.00–22.00<br>(330.2–558.8)|4.25–6.00<br>(108.0–152.4)|Retro size B/size<br>29.00–36.00 (736.6–914.4)| |CH interior 200A MCB 32 circuits|**RCCH32B200I**|**RCCHFRAME**|**CH8JF**|34.00–41.00|13.00–22.00|4.25–6.00|Retro size C/size| |||||(863.3–1041.4)|(330.2–558.8)|(108.0–152.4)|34.00– 41.00 (863.3–1041.4)| |CH interior 225A MLO 42 circuits|**RCCH42L225I**|**RCCHFRAME**|**CH8GF**|34.00–41.00|13.00–22.00|4.25–6.00|Retro size C/size| |CH interior 200A MCB 42 circuits|**RDCH42B200I**|**RDCHFRAME**|**CH8KF**|(863.3–1041.4)<br>37.00–45.00|(330.2–558.8)<br>13.00–22.00|(108.0–152.4)<br>4.25–6.00|34.00– 41.00 (863.3–1041.4)<br>Retro size D/size| |||||(939.8–1143.0)|(330.2–558.8)|(108.0–152.4)|37.00–45.00 (939.8–1143.0)| |CH interior 225A MLO 42 circuits|**RDCH42L225I**|**RDCHFRAME**|**CH8KF**|37.00–45.00|13.00–22.00|4.25–6.00|Retro size D/size| |||||(939.8–1143.0)|(330.0–558.8)|(108.0–152.4)|37.00–45.00 (939.8–1143.0)| ## _**Notes**_ > 1 Other options are available. > 2 CH retrofit interiors and collar cartons are color coded to ensure accuracy of kit. **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-28** Loadcenters 5 Type CH ## **Surge Panel** ## _**Factory-Installed Surge Protection**_ ## **Product Description** - Includes a CHSPULTRA and a two-pole 15A circuit breaker Eaton’s Type CH Surge Loadcenter includes a factory-mounted and wired surge suppressor device. There is a knockout in the cover that allows the user to view the status indication lights on the surge suppressor. The CH Surge Loadcenter reduces the surge current, helping to protect sensitive home electronic equipment. - Increases the effectiveness of surge protection due to reduced lead length - A modified deadfront allows for easy viewing of indicating lights ## _**Surge Ready**_ - Provides a mounting provision for CHSPULTRA - A modified deadfront allows for easy viewing of indicating lights Save labor by installing a factorymounted surge protective device. ## **Replacement Covers for Surge Panels** ## **Surge Panel** **5** |**Catalog Number**|**Cover Number**|**Replacement Module**| |---|---|---| |**CHSUR22B100D**|CHPC8DF|CHSPT2ULTRA| |**CHSUR24L125D**|CHPC8DF|CHSPT2ULTRA| |**CHPC22B100D**|CHPC8DF|CHSPT2ULTRA| |**CHPC24L125D**|CHPC8DF|CHSPT2ULTRA| |**CHPC12L125C**|CHPC8CF|CHSPT2ULTRA| |**CHPC30B100J**|CHPC8JF|CHSPT2ULTRA| |**CHPC32L150J**|CHPC8JF|CHSPT2ULTRA| |**CHSUR32B150L**|CHPC8B32LF|CHSPT2ULTRA| |**CHSUR32B200L**|CHPC8B32LF|CHSPT2ULTRA| |**CHSUR32L225L**|CHPC8B32LF|CHSPT2ULTRA| |**CHPC32B125L**|CHPC8B32LF|CHSPT2ULTRA| |**CHPC32B150L**|CHPC8B32LF|CHSPT2ULTRA| |**CHPC32B200L**|CHPC8B32LF|CHSPT2ULTRA| |**CHPC32N200L**|CHPC8B32LF|CHSPT2ULTRA| |**CHSUR42B200L**|CHPC8B42LF|CHSPT2ULTRA| |**CHPC42B150L**|CHPC8B42LF|CHSPT2ULTRA| |**CHPC42B200L**|CHPC8B42LF|CHSPT2ULTRA| |**CHPC42N200L**|CHPC8B42LF|CHSPT2ULTRA| |**CHSUR42L225L**|CHPC8L42LF|CHSPT2ULTRA| |**CHPC42L225L**|CHPC8L42LF|CHSPT2ULTRA| **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-29** Loadcenters 5 Type CH **5** ## **Further Information** |**Publication**|| |---|---| |**Number**|**Description**| |CA08100002E|Volume 1—Residential and Light Commercial Catalog, Tab 1| |CA08100011E|Volume 9—OEM Product Guide| ## **Pricing Information** _Price and Availability Digest_ (PAD) Vista/VISTALINE™ Discount Symbol 22CD **Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions** CA08100014E—October 2016 www.eaton.com **V12-T5-30**
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →