Image not available
Illustrative purposes only
GB40S12K01
AC/DC Open Frame Power Supply (PSU), ITE, Industrial & Medical, 1 Output, 40 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: GB40 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.4A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 13.75 € |
| Current stock | 25+ |
| Lead time | 30 days |
40W Single Output **GB40 Family** Medical & Industrial Grade ## **FEATURES AND BENEFITS** **==> picture [25 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> Medical<br>Industrial<br>**----- End of picture text -----**<br> 40W Open Frame and PCB-mount Power Supply 2.0” x 4.0” x 1.0” Package Universal Input 90-264VAC <0.1W No Load Input Power Approved to CSA/EN/IEC/UL62368-1 Meets Heavy Industrial and IEC60601-1-2 4[th] Edition Levels of EMC Approved to CSA/EN/IEC/UL60601-1, 3[rd] Edition E-cap Life of >8 Years >1,000,000 Hours MTBF 3 Year Warranty Meets Class B Radiated & Conducted EMI, with Margin Note: *Consult Factory for compliance information. ## **MODEL SELECTION** **==> picture [560 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |Rated|Output|Ripple &|Line|Load|Input|Output| |Model Number|[2]|Volts| |Current|Power|Noise|[1]|Regulation|Regulation|Class/Termination|Termination| |GB40S05K01|5.0V|5.0A|25W|75mV pk-pk|±1%|±5%|Class I (Grounded) input,| |4-pin AMP/Molex type| |GB40S09K01|9.0V|4.0A|36W|90mV pk-pk|±1%|±5%|connector for “K” and “C”| |Change “K” to “C” for|versions| |GB40S12K01|12.0V|3.4A|40W|120mV pk-pk|±1%|±5%| |class II input| |GB40S18K01|18.0V|2.22A|40W|120mV pk-pk|±1%|±5%|Change “K” to “P” for PCB| |mount pins, class I input|PCB mount pins for| |GB40S24K01|24.0V|1.7A|40W|240mV pk-pk|±1%|±5%| |“P” and “V” versions| |GB40S48K01|48.0V|0.83A|40W|480mV pk-pk|±1%|±5%|mount pins”, class II input| **----- End of picture text -----**<br> Note: 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 2. Other output voltages available, consult factory. 3. All specifications are typical at 230VAC, full load, at 25°C ambient unless noted. ## **INPUT** ## **OUTPUT** **==> picture [246 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Input Voltage and| |100-240VAC, ±10%, 47-63Hz, 1Ø| |Frequency| |Input Current|115VAC: 1.2A, 230VAC: 0.6A| |Inrush Current|264VAC, cold start: will not exceed 40A peak| |Input Fuses|3.15A, 250VAC fuse in both line and neutral| |Earth Leakage Current|<500UA@264VAC,|60Hz,|NC| |(Input to Ground)|<1mA@264VAC,|60Hz,|SFC| |Earth Leakage Current|<100uA@264VAC,|60Hz,|NC| |(Output to Ground)| |Efficiency|>88%, typical| |Power Factor|0.9, min., 230VAC, 80-100% load vector, 25°C| |ambient| **----- End of picture text -----**<br> **==> picture [278 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Turn On Time|<700ms| |Hold-Up Time|20ms/100VAC at full load| |25W-40W continuous – See models chart for specific| |Output Power| |voltage model ratings| |Output Voltage|See models chart| |500|U|s resp. time for return to w/in 0.5% of final| |value for any 50% load step from 5% to 100% of| |Transient Response| |rated|load, Ai/At<0.2A/us| |Max voltage deviation is +/-3.5%| |Regulation|See models chart| **----- End of picture text -----**<br> Note: All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted. Note: All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted. GB40 Datasheet v0420 Copyright © 2020 SL Power Electronics Corp. All rights reserved. Page 1 40W Single Output Medical & Industrial Grade ## **GB40 Family** **PROTECTION SAFETY** Overtemperature Will shutdown upon an overtemperature condition, ITE/Industrial Safety EN/IEC/UL62368-1 Protection Auto-recovery Medical Safety EN/IEC/UL60601-1, 3[rd] edition 130% to 160% of rated output current value, Overload Protection Hiccup mode Short Circuit Protection Hiccup mode **EMI/EMC COMPLIANCE** 120% to 150% of nominal output voltage, Overvoltage Protection Hiccup Mode ~~—~~ EN55032, EN55011/CISPR11 Class B, FCC Part Conducted Emissions 15.107, Class B: 6db margin type, at 115 and 230VAC EN55032, EN55011/CISPR11 Class B, FCC Part **RELIABILITY** Radiated Emissions 15.109, Class B: 3db margin type, at 115 and 230VAC >1,000,000 hours, full load, 110 & 220VAC input, Electro-Static Discharge EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, MTBF 25°C amb., per telcordia 332 issue 6, stress method (ESD) Immunity on +/- 15kV air, Criteria A Power Ports IEC60601-1-2, 4[th] edition, Table 4 >8 year life based on calculations at 115VAC/60Hz E-cap Life & 230VAC/50Hz, ambient 25°C at 24 hrs per day, Radiated RF EM Fields EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, ~~—~~ 365 days/year, 6 power up cycles per day Susceptibility 80% AM at 1kHz IEC60601-1-2, 4[th] edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, Electrical Fast **ISOLATION SPECIFICATIONS** 100Khz rep rate, 40A, Criteria A Transients (EFT)/Bursts IEC60601-1-2, 4[th] edition, Table 5 Input-Output : 4000VAC (2 MOPP) Surges, Line to Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, Isolation Input-Ground : 1500VAC (1 MOPP) (Diff Mode) and Line to +/-4kV CM, Criteria A Output-Ground : 1500VAC (1 MOPP) GND (CMN Mode) Surpasses IEC60601-1-2, 4[th] edition requirements Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: TBD EN55022/IEC61000-4-6, 3.6V/m – Level 4, (0.15 to ~~—_~~ Conducted Disturbances 80Mhz; and 12V/m) in ISM and amateur radio bands Induced by RF Fields between 0.15Mhz and 80Mhz, 80% AM at 1KHz IEC60601-1-2, 4[th] edition, Table 5 **ENVIRONMENT** Rated Power Frequency EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60Hz Magnetic Fields IEC60601-1-2, 4[th] edition, Table 4 -25 ~ +70°C, see derating curve for operation above Operating Temperature 60°C EN55024/IECEN61000-4-11: StorageTemperature -40°C ~ +85°C --100% dip for 10ms, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20ms, 0 deg., Cooling Convection Voltage Interruptions, Criteria A Dips, Sags & Surges --100% dip for 5000 ms (250/300 cycles), Criteria B Relative Humidity 5% to 90%, Non-condensing --60% dip for 100ms, Criteria B Operating: 0.003g/Hz, 1.5grms overall, 3 axes, --30% dip for 500ms, Criteria A 10 min/axis, 1-500Hz IEC60601-1-2, 4[th] edition, Table 5 Non-Oper.: random waveform, 3 minutes per axis, 3 Vibration Harmonic Current axes and sine waveform, vib. frequency/acceleration: EN55011/EN61000-3-2, Class A Emissions 10-500Hz/1g, sweep rate of 1 octave/minutes, vibration time of 10 sweeps/axes, 3 axes Flicker Test EN61000-3-3 Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks Note: 1. The power supply is considered a component which will be installed into a final equipment. total The final equipment must be re-confirmed that it still meets EMC directives. Shock Non-Operating: Half-sine waveform, impact 2. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult°C ambient unless noted. ConsultC ambient unless noted. Consult acceleration of 50G, pulse duration of 6ms, factory for information regarding testing for or usage under special environments. Number of shocks: 3 for each of the three axis 48.3 x 101.6 x 25mm 2.0 x 4.0 x 0.97 inch (Height is from top of tallest Dimensions component to max. component pin protrusion on the bottom) Weight 110g ~~_~~ Note: Same dimensions for PCB & Pin Variants. GB40 Datasheet v0420 Copyright © 2020 SL Power Electronics Corp. All rights reserved. - Note: 1. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 2. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult°C ambient unless noted. ConsultC ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Page 2 40W Single Output Medical & Industrial Grade ## **GB40 Family** ## **DERATING CURVE** **==> picture [368 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C)<br>Output Power (% of rated)<br>**----- End of picture text -----**<br> ## **MECHANICAL DRAWING** ## **Mounting hole diameter: 3.2mm (0.125”) 4 places** GB40 Datasheet v0819 Copyright © 2019 SL Power Electronics Corp. All rights reserved. Page 3 ## **GB40 Family** ## 40W Single Output Medical & Industrial Grade ## **CONNECTOR AND TERMINATION INFORMATION** |Version<br>Connector Pinout<br>Connector Type/Part No.<br>Input Connections|Connector Pinout<br>Connector Type/Part No.<br>Output Connections| |---|---| |Open Frame:<br>“K”, “C”<br>Connector:<br>Pin 1: AC LINE<br>an;SPaUND<br>TE/AMPP/N 640445-5 (2pinsremoved<br>Pin 5: AC NEUTRAL|Pin 1: +Vout<br>Pin 2: +Vout<br>Pin 3: -Vout<br>Pin 4: -Vout<br>Connector:<br>TE/AMP P/N 640445-4<br>Mating Connector:<br>TE/AMP P/N 640250-4,<br>Pins= 770476-1| |PCB Mount:<br>“P”, “V”<br>Pin 1: AC Line<br>Pin 2: GND<br>Pin 3: AC Neutral<br>Pencom PI3207 or equivalent|Pin 4: +Vout<br>Pin 5: +Vout<br>Pin 6: -Vout<br>Pin 7: -Vout<br>Pencom PI3207 or equivalent| Disclaimer : The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. GB40 Datasheet v0420 Copyright © 2020 SL Power Electronics Corp. All rights reserved. Page 4
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →