- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (21-Jan-2025)
- Product Range: GB10 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 9V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 10W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 9.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SL POWER GB10 SERIES**
12 Watts Single Output Medical & Industrial Grade
Advanced Energy’s SL Power GB10 series of open-frame AC-DC power supplies comprises six single output models. All models feature medical safety approvals and accept a universal input of 90 to 264 VAC. These compact switch-mode power supplies feature output overvoltage, overload protection, with short-circuit protection on the output. GB10 series power supplies provide 12 Watts of output power with free air convection cooling.
## **AT A GLANCE**
## **Total Power**
**12 Watts**
**Input Voltage**
**90 to 264 VAC**
**# of Outputs**
**Single**
## **SPECIAL FEATURES**
- 1.6” x 3.38” x 1.0”
- (40.6 mm x 85.8 mm x 25.4 mm)
## **SAFETY**
- CSA/IEC/EN/UL62368-1
- CSA/IEC/EN/UL60601-1, 3.2 Ed.
- 12 W Open Frame Power Supply Convection Cooled
- Universal Input 90 to 264 VAC
- <0.1 W No Load Input Power
- Meets Class B Radiated & Conducted EMI, with margin
- Meets Heavy Industrial and IEC60601-1-2 4th Edition Levels of EMC
- >10 Year E-cap Life
- >1,000,000 Hours MTBF
- 3 Year Warranty
Note: Consult Factory for compliance information.
@2023 Advanced Energy Industries, Inc.
**GB10**
## **ELECTRICAL SPECIFICATIONS**
**==> picture [479 x 424] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input<br>Input Ra nge 90 to 264 VAC, 47 to 63 Hz, 1Ø<br>Input Current 0.45 A @ 115 VAC, 0.22 A @ 230 VAC<br>Inrush Current 40 A max., cold start @ 264 VAC input<br>Input Fuses 3.15 A, 250 VAC fuses provided in both line & neutral<br>Leakage Current<br>Input to Earth <500 μA @ 264 VAC, 60 Hz, NC; <1 mA @ 264 VAC, 60 Hz, SFC<br>Output to Earth <100 μA @ 264 VAC, 60 Hz, NC; <500 μA @ 264 VAC, 60 Hz, SFC<br>Efficiency 88% typical<br>Isolation Voltage<br>Input/Ground: 1500 VAC (1 MOPP)<br>Input/Output: 4000 VAC (2 MOPP)<br>Output/Ground: 1500 VAC (1 MOPP)<br>Output<br>Maximum Power 10 to 12 W continuous. See "Ordering Information" for specific voltage model ratings<br>Power Factor >0.9, 230 VAC, 80% to 100% load, 25OC ambient<br>Output Voltage See "Ordering Information"<br>Total Load Regulation See "Ordering Information"<br>Turn On Time <800 ms<br>Hold-up Time 20 ms @ 100 VAC, full load, “K” and ”C” input options<br>10 ms @ 100 VAC, full load, “P” input options<br>Transient Response 500 μs typ. for return to within 0.5% of nominal output voltage, 50% load step from 5% to 100% of rated load,<br>∆ i/ ∆ t <0.2 A/μs. Max voltage deviation = 3.5%<br>Reliability<br>MTBF >1,000,000 hours, full load, 110 VAC & 220 VAC input, 25OC ambient, per telcordia 332 issue 6, stress method<br>E-Cap Life >10 years life based on calculations at 115 VAC/60Hz & 230 VAC/50Hz, ambient 25OC at 24 hrs/day, 365<br>days/year, 6 power up cycles/day<br>Protection<br>Input Fuse 3.15 A / 250 V internal fuse in both line & neutral<br>Overtemperature Protection Will shutdown upon an overtemperature condition, auto-recovery<br>Short circuit Protection Hiccup mode<br>Overload Protection 130% to 160% of rated output current value. Hiccup mode.<br>Overvoltage Protection 120% to 150% of nominal output voltage. Hiccup Mode.<br>**----- End of picture text -----**<br>
## **ENVIRONMENTAL SPECIFICATIONS**
**==> picture [479 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating: 0.003 g/Hz, 1.5 grms overall, 3 axes, 10 min/axis, 1Hz to 500Hz<br>Vibration Non-operating: random waveform, 3 mins/axis, 3 axes and sine waveform, vib. frequency/acceleration:<br>10Hz to 500Hz/1g, sweep rate of 1 octave/minutes, vibration time of 10 sweeps/axes, 3 axes<br>Operating: Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total<br>Shock Non-operating: Half-sine waveform, impact acceleration of 50g, pulse duration of 6ms, number of shocks: 3<br>for each of the 3 axis<br>Operating Temperature -20°C to +70°C, see derating curve for operation above 50°C<br>Storage Temperature -40°C to +85°C<br>Cooling Convection<br>Relative Humidity 5% to 95%, non-condensing<br>**----- End of picture text -----**<br>
**2 advancedenergy.com**
**GB10**
## **DERATING CURVE**
## **EMI/EMC COMPLIANCE**
|Conducted Emissions|EN55032, EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin type, at 115VAC and 230VAC|
|---|---|
|Radiated Emissions|EN55032, EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin type, at 115VAC and 230VAC|
|Electro-Static Discharge (ESD)<br>Immunity on Power Ports|EN55024/IEC61000-4-2, Level 4: ±8kV contact, ±15kV air, Criteria A IEC60601-1-2 4th Edition, Table 4|
|Radiated RF EM Fields Susceptibility<br>3|EN55022/EN61000-4-3, 10V/m, 80MHz to 2.7GHz, 80% AM at 1 kHz IEC60601-1-2 4th Edition, Table 4|
|Electrical Fast Transients (EFT)/Bursts|EN55024/IEC61000-4-4, Level 4, ±4.4kV, 100Khz rep rate, 40A, Criteria A IEC60601-1-2 4th Edition, Table 5|
|Surges, Line to Line (DM) and Line to<br>Ground (CM)|EN55024/IEC61000-4-5, Level 4, ±2kV DM, ±4kV CM, Criteria A Surpasses IEC60601-1-2 4th Edition<br>requirements|
|Conducted RF Immunity|EN55022/IEC61000-4-6, 3.6V/m – Level 4, (0.15MHz to 80MHz; and 12V/m) in ISM and amateur radio<br>bands between 0.15MHz and 80MHz, 80% AM at 1KHz IEC60601-1-2 4th Edition, Table 5|
|Line Surge Immunity|EN55024/IEC61000-4-5, Level 3, 1 kV diff., 2 kV common-mode, criteria A<br>1<br>Level 4, 2 kV diff., 4 kV common-mode, criteria B<br>1|
|Conducted RF Immunity|EN55022/IEC61000-4-6, Level 4, 3 V/m, 0.15 to 80 MHz; and 10 V/m in ISM and amateur radio bands<br>between 0.15 and 80 MHz, 80%AM at 1 kHz, criteria A<br>1|
|Power Frequency Magnetic Field<br>Immunity|EN55024/IEC1000-4-8, Level 4: 30A/m, 50Hz/60Hz, IEC60601-1-2 4th Edition, Table 4|
|Voltage Dip Immunity|EN55024/IECEN61000-4-11:<br>--100% dip for 10ms, at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°, 100% dip for 20ms, 0°, Criteria A<br>(Criteria B for “P” option)<br>--100% dip for 5000ms (250/300 cycles), Criteria B<br>--60% dip for 100ms, Criteria B<br>--30% dip for 500ms, Criteria A<br>IEC60601-1-2 4<br>thEdition, Table 5|
|Line Harmonic Emissions|EN55011/EN61000-3-2, class A|
|Flicker Test|EN61000-3-3|
Notes:
1. The power supply is considered a component which will be installed into a final equipment.
2. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing or for usage under special environments.
**advancedenergy.com 3**
**GB10**
## **ORDERING INFORMATION**
**==> picture [479 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model Output Maximum Maximum Ripple & Line Load Input Class/ Output<br>Number2 Voltage Load Power Noise1 Regulation Regulation Termination Termination<br>GB10S05K01 5.0 V 2.0 A 10.0 W 75 mV pk-pk ± 1% ± 5%<br>Class I (Grounded)<br>GB10S07K01 7.5 V 1.3 A 10.0 W 75 mV pk-pk ± 1% ± 5%<br>input, 3-pin 4-pin AMP/Molex<br>GB10S09K01 9.0 V 1.0 A 10.0 W 90 mV pk-pk ± 1% ± 5% AMP/Molex type type connector<br>GB10S12K01 12.0 V 1.0 A 12.0 W 120 mV pk-pk ± 1% ± 5% connector. Change for “K” and “C”<br>“K” to “C” for Class versions<br>GB10S15K01 15.0 V 0.8 A 12.0 W 150 mV pk-pk ± 1% ± 5%<br>II input<br>GB10S24K01 24.0 V 0.5 A 12.0 W 240 mV pk-pk ± 1% ± 5%<br>**----- End of picture text -----**<br>
Notes:
1. Ripple & noise are measured at 20 MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 μF & 47 μF parallel capacitor.
- 2 . Other output voltages available, consult factory.
3. All specifications are typical at 230 VAC, full load, at 25°C ambient unless noted.
## **PIN ASSIGNMENTS**
**==> picture [479 x 205] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connector GB10<br>PIN 1 AC Line<br>PIN 2 N/C<br>Input Connector ("K" version) PIN 3 Ground<br>PIN 4 N/C<br>PIN 5 AC Neutral<br>PIN 1 AC Line<br>PIN 2 N/C<br>Input Connector ("C" version) PIN 3 N/C<br>PIN 4 N/C<br>PIN 5 AC Neutral<br>PIN 1 +Vout<br>PIN 2 +Vout<br>DC Output Connector<br>PIN 3 -Vout<br>PIN 4 -Vout<br>**----- End of picture text -----**<br>
## **CONNECTORS**
**==> picture [477 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connector Mating Connector<br>Input Connector TE/AMP P/N 640445-5 TE/AMP P/N 640250-5. Terminals: 770476-1<br>DC Output Connector TE/AMP P/N 640445-4 TE/AMP P/N 640250-4. Terminals: 770476-1<br>**----- End of picture text -----**<br>
**4 advancedenergy.com**
**GB10**
## **MECHANICAL DRAWING**
Notes:
1. All dimensions in mm
2. Dimension: 1.60” x 3.23” x 1.04” (40.0mm x 82.0mm x 26.5mm)
3. Weight: 100 g
**advancedenergy.com 5**
**==> picture [596 x 270] intentionally omitted <==**
## **ABOUT ADVANCED ENERGY**
Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes.
Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power.
## **TRUST**
For international contact information, visit advancedenergy.com.
powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832
Specifications are subject to change without notice. Not responsible for errors or omissions. ©2025 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc.
ENG-GB10-04.03.25
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →