Image not available
Illustrative purposes only
G9EK-1-UTU DC12
Power Relay, SPST-NO, 12 VDC, 120 A, G9EK-1 Series, Flange, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON ELECTRONIC COMPONENTS
- Product type: Power Relays
- SVHC: No SVHC (25-Jun-2025)
- Coil Type: Non Latching
- Coil Voltage: 12VDC
- Product Range: G9EK-1 Series
- Relay Mounting: Flange
- Coil Resistance: 48ohm
- Contact Current: 120A
- Relay Terminals: Screw
- Contact Material: -
- Contact Voltage VAC: -
- Contact Voltage VDC: 500V
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 112.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **DC Power Relays G9EK-1**
## **Gasless High-capacity DC Power Relay that achieves carbon neutrality.**
- Achieves 500 VDC, 120 A high capacity with bidirectional switching performance without the need of gas filling and sealed structure of the switching section.
- A compact relay (64.2 x 86 x 47.7 mm (H x W x L)) capable of switching 500 A at 400 VDC max.
- Achieves industry-leading* low power consumption. Contributes to energy saving of customer's system.
- Vibration and impact resistant performance that can be installed in mobility.
- Certified by UL, TUV.
- Based on OMRON investigation in October 2024
Refer to " **DC Power Relays Common Precautions** ".
## **Model Number Legend**
G9EK-
— — — — 1 2 3 4
**1. Number of Poles**
1: 1 pole
**2. Contact Form** Blank: SPST-NO
**3. Special Functions**
Blank: Standard
U: Low voltage operation
**4. Approved standard** Blank: Standard UTU: UL, TUV certification
## **List of Models**
|**Models**|Terminals|Terminals|Contact form|Coil rated voltage|Model|
|---|---|---|---|---|---|
||Coil terminals|Contact terminals||||
|**Switching/current**<br>**conduction models**|Connector|Screw terminals|SPST-NO|12 VDC|G9EK-1-U|
||Connector|Screw terminals|SPST-NO|12 VDC|G9EK-1-UTU|
**Note: 1.** Mating Connector Part No.6098-2456, 6098-0593 (SUMITOMO), NO.7283-1020, 7183-2414 (YAZAKI)
**1** omrRon ~~a~~
**G9EK-1**
## **Ratings**
## **Coil**
|**Item**<br>**Model**|Rated voltage|Rated current<br>(mA)|Rated current<br>(mA)|Coil resistance<br>(Ω)|Must-operate<br>voltage<br>(V)|Must-release<br>voltage<br>(V)|Maximum<br>voltage<br>(V)|Power<br>consumption<br>(W)|
|---|---|---|---|---|---|---|---|---|
|**G9EK-1-U**|12 VDC|333||36|6.5 Max|0.6 Min|16|Approx. 4|
|**G9EK-1-UTU**|12 VDC|250||48|9.0 Max|0.6 Min|16|Approx. 3|
|**Note: 1.** The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%<br>**Note: 2.** The figures for the operating characteristics are for a coil temperature of 23°C<br>**Note: 3.** The figures for the maximum voltage that can be applied to the relay coil and at 23°C within 10 minutes.<br>**Contacts**<br>**Item**<br>G9EK-1-U / G9EK-1-UTU<br>**Rated load (resistive load)**<br>120 A at 500 VDC<br>**Rated carry current**<br>120 A<br>**Maximum switching voltage**<br>500 VDC<br>**Maximum switching current**<br>120 A|||||||||
|**Item**|||G9EK-1-U / G9EK-1-UTU||||||
|**Rated load (resistive load)**|||120 A at 500 VDC||||||
|**Rated carry current**|||120 A||||||
|**Maximum switching voltage**|||500 VDC||||||
|**Maximum switching current**|||120 A||||||
## **Characteristics**
|**Item**<br>**Model**|**Item**<br>**Model**|G9EK-1-U / G9EK-1-UTU|
|---|---|---|
|**Contact resistance *1**||30 mΩmax. (0.4 mΩtypical)|
|**Contact voltage drop**||0.2 V max. (for a current of 120 A)|
|**Operate time**||50 ms max. (Coil rated voltage not including bounce time)|
|**Release time**||30 ms max. (Coil rated voltage without absorb coil surge)|
|**Insulation**<br>**resistance *2**|**Between coil and contacts**|1000 MΩmin.|
||**Between contacts of the same polarity**|1000 MΩmin.|
|**Dielectric**<br>**strength**|**Between coil and contacts**|2500 VAC 1 min|
||**Between contacts of the same polarity**|2500 VAC 1 min|
|**Impulse withstand voltage *3**||4000 V|
|**Vibration**<br>**resistance**|**Destruction**|33 Hz Acceleration: 45 m/s2|
||**Malfunction**|10 to 500 Hz Acceleration: 45 m/s2|
|**Shock**<br>**resistance**|**Destruction**|490 m/s2(pulse duration: 11 ms)|
||**Malfunction (Energized)**|980 m/s2(pulse duration: 11 ms detection time: 10μs)|
||**Malfunction (De-energized)**|107.8 m/s2(pulse duration: 11 ms detection time: 10μs)|
|**Mechanical endurance *4**||200,000 ops. min.|
|**Electrical endurance (resistive load) *5**||(1) 120 A at 500 VDC (1000 operations min.)<br>(2) 60 A at 500 VDC (6000 operations min.)|
|**Short-time carry current**||Refer the Carry Current vs Energizing Time Graph|
|**Maximum interruption current**||500 A at 400 VDC (1 operations min.)|
|**Ambient operating temperature**||-40 to 70°C (without freezing or condensation)|
|**Ambient operating humidity**||5% to 85%|
|**Weight(Including accessories)**||Approx.340g/ Approx.310g|
**Note:** Unless otherwise specified, the above values are the initial values at an ambient temperature of 23°C and ambient pressure of 1 atm. In addition, these are values obtained under each condition in a single test, and do not guarantee values that can be obtained under combined conditions of each rating value and performance value (for example, maximum interruption after electrical endurance, maximum interruption after mechanical endurance, etc.).
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
*2. The insulation resistance was measured with a 1000-VDC megohmmeter.
*3. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 x 50 μ s).
*4. The mechanical endurance was measured at a switching frequency of 3,600 operations/hr.
*5. The electrical endurance was measured at a switching frequency of 60 operations/hr.
The switching performance and interruption performance were measured with varistor connected to absorb coil surge.
**2**
**G9EK-1**
**Engineering Data**
## **G9EK-1-U Switching/Current Conduction Models** ~~PT~~
## **Maximum Switching Capacity**
**==> picture [142 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
1000<br>100<br>10<br>1 a<br>10 100 1000<br>Switching voltage (V)<br>Switching current (A)<br>**----- End of picture text -----**<br>
## **Carry Current vs Energizing Time**
## **Electrical Endurance (Switching Performance)**
**==> picture [324 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
10000 100000<br>10000<br>1000<br>1000<br>100<br>100<br>10<br>10 1<br>10 100 1000 10 100 1000<br>Switching current (A) Carry Current (A)<br>Operations Energizing time (s)<br>**----- End of picture text -----**<br>
## **Must-operate Voltage and Must-release Voltage Distributions**
**==> picture [148 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Time Characteristic Distributions<br>**----- End of picture text -----**<br>
**==> picture [326 x 409] intentionally omitted <==**
**----- Start of picture text -----**<br>
35 35<br>Must-operate voltage Operate time<br>30 | | | fe Must-release voltage FT 30 fT | tT | | y= Release time<br>25 ee 25 Pt | | | | |<br>20 PE 20 Pt tT tT TT | Et<br>15 Po 15 Bee Tee<br>10 ee 10 PP it | | Ee<br>5 Pe eee 5 Pt ity | | EE<br>0 0 Pi) 20 40 ee 60 80 100 0 0.0 PP 5.0 uP 10.0 RE 15.0 ET 20.0 25.0 30.0<br>Percentage of rated voltage (%) Time (ms)<br>Vibration Malfunction Vibration Resistance<br>100 10.0<br>90 8.0<br>80 To Unconfirmed area 6.0 SS Must-operate voltage Must-release voltage<br>4.0<br>7060 eTOn on Coon 2.00.0 pdes<br>50 -2.0<br>40 Or0 eeeoooel -4.0 ae<br>-6.0<br>30<br>0 -8.0 po<br>20 a Confirmed area -10.0 Po<br>10 0 TT Start After test<br>0 eB Characteristics are measured after vibration at the frequency<br>1 10 100 1000 of 33Hz, 45m/s [2] is applied to the test piece (not energized) in<br>Frequency (Hz) vertical direction for 4 hours and in each left, right, front and<br>back directions for 2 hours.<br>Shock Malfunction Shock Resistance<br>10.0<br>8.0<br>1000 Z 6.0 Must-operate voltage<br>Must-release voltage<br>800 4.0<br>Y' 600 X' 2.0<br>400 0.0<br>200 Energized -2.0<br>0 Deenergized<br>-4.0<br>-6.0<br>X Y'<br>-8.0<br>-10.0<br>Start After test<br>Z'<br>Characteristics were measured after applying a shock<br>of 490 m/s [2] to the test piece 3 times each in 6<br>directions along 3 axes. The percentage rate of<br>change is the average value for all of the samples.<br>Number of Relays Number of Relays<br>2)Acceleration (m/s Rate of change (%)<br>Rate of change (%)<br>**----- End of picture text -----**<br>
## **Vibration Malfunction**
## **Shock Malfunction**
**3**
**G9EK-1**
(Unit: mm)
**Dimensions** For CAD information, please visit our website, which is noted on the last page. CAD Data marked products, 2D drawings and 3D CAD models are available.
## **G9EK-1-U**
## **G9EK-1-UTU**
**==> picture [503 x 405] intentionally omitted <==**
**----- Start of picture text -----**<br>
79.7 ELECTRIC SCHEMATIC<br> 2-6.3-dia.±0.1 (COLLAR INSIDE) 67 TERMINAL 2PLACES 6.5-dia. HOLE<br>49 AND M6-NUT t: 5 mm 3<br>1<br>2<br>47.7 35 17 4<br>1<br>2<br>71<br>86 16 (TERMINAL)<br>Mounting Hole Dimensions<br>10 85 (TERMINAL) 43 (TOP VIEW)<br> 3 (TERMINAL) Two, M6 or 6.5-dia. holes<br>A<br>(INCLUDING 64.2 (INCLUDING 60.3 [+0.6] - 0.4 67±0.1<br>COLLAR) 17.8 COLLAR)<br>38.1<br> 35±0.1<br>TOLERANCE UNLESS SPECIFIED MATING CONNECTOR<br>DIMENSION TOLERANCE SUMITOMO 6098-2456, 6098-0593<br>10 or lower ±0.3 YAZAKI 7283-1020, 7183-2414<br>10 to 50 mm ±0.5<br>50 or higher ±1<br>4 3<br>Detail view A<br>**----- End of picture text -----**<br>
## **Approval Standard**
**UL/C-UL Certificated: (File No. E41515)**
|**UL/CUL Cifid**<br>**Fil N E41515**|**UL/CUL Cifid**<br>**Fil N E41515**|**UL/CUL Cifid**<br>**Fil N E41515**|**UL/CUL Cifid**<br>**Fil N E41515**|**UL/CUL Cifid**<br>**Fil N E41515**|
|---|---|---|---|---|
|**- ertcate:**<br> **(e o.)**|||||
|**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Number of test operations**|
|**G9EK-1-UTU**|SPST-NO(1a)|12 VDC|500 VDC 60A (Resistive)|6,000|
||||500 VDC 120A (Resistive)|1,000|
|**EN/IEC, TÜV Certificated:**<br>**(Certificate No. 50695311)**|||||
|**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Number of test operations**|
|**G9EK-1-UTU**|SPST-NO(1a)|12 VDC|500 VDC 120A (Resistive)|1,000|
|**G9EK-1-UTU**|||||
|**Creepage distance (required value)**<br>||8.0 mm min. (IEC) /8.0 m|m min. (UL)||
|**Clearance (required value)**<br>||5.5 mm min. (IEC) /5.5 m|m min. (UL)||
|**Insulation material group**<br>I||IIa|||
|**Type of insulation**|**coil-contact circuit**<br>|Basic (500 V, OV-cat.III, Pollution degree 3, up to 2,000 m above sea level|||
|**Type of interruption**<br>||Micro disconnection|||
|**Rated insulation voltage**<br>||500 V|||
|**Rated voltage system**<br>||500 V|||
|**Category of protection (IEC61810-1)**<br>||RTI|||
|**Flammability class (UL94)**<br>||V-0|||
|**Coil insulation system (UL)**<br>||Class F|||
**4**
**G9EK-1**
## **Precautions**
## **Please refer to** _**Safety Precautions for DC Power Relays**_ **for correct use.**
## **WARNING**
Take measures to prevent contact with charged parts when using the Relay for high voltages. ~~A~~ This relay is a high-voltage and high-current type. Do not apply a contact voltage or current in excess of the rated values given in the data sheet. Do not exceed the specified number of switching operations. Otherwise, it may result in abnormal heat generation, smoke generation, or fire. Use only within the specified operating conditions.
13. The distance between crimp terminals or other conductive parts will be reduced and insulation properties will be lowered if wires are laid in the same direction from the contact terminals. Use insulating coverings, do not wire in the same direction, and take other measures as required to maintain insulation properties.
14. Use either a varistor, or a diode plus Zener diode as a protective circuit against reverse surge in the relay coil. (Each relay type uses a different voltage method such as Varistor voltage and Zener voltage, so please contact OMRON sales representative. Please perform adequate performance tests with your equipment.) Using a diode alone will reduce the switching characteristics.
15. When wiring to the contact terminals, use screws which are longer than 8mm + the thickness of the material being fastened + the washer of the screw. Apply torque after the screws are placed.
16. When wiring to the contact terminals, avoid overloading the terminals and wires.
Recommended Wire Size
- **Precautions for Correct Use Model Model Size G9EK-1-U** 30 mm[2] or more
- Refer to the relevant catalog for common precautions. ~~————————————~~ 1. Be sure to tighten all screws to the appropriate torque given **G9EK-1-UTU** 30 mm[2] or more below. Loose screws may result in burning due to abnormal heat 17. This Relay is limited for mounting direction due to the specification generation during energization.
17. This Relay is limited for mounting direction due to the specification of operation voltage.
- M8 screws: 8.82 to 9.80 N·m
Do not use in any other direction except as indicated in below chart. There is a risk of reduced operational lifetime for failuret to observe this warning.
- M6 screws: 3.92 to 4.90 N·m
- M5 screws: 1.57 to 2.35 N·m
- M4 screws: 0.98 to 1.37 N·m
Upper side Contact terminal ty Coil terminal (Connector) an
- M3.5 screws: 0.75 to 1.18 N·m
2. Do not drop or disassemble this Relay. Not only may the Relay fail to meet the performance specifications, it may also result in damage, electric shock, or burning.
3. Do not use these Relays in strong magnetic fields of 800 A/m or higher (e.g., near transformers or magnets). The arc discharge that occurs during switching may be bent by the magnetic field, resulting in flashover or insulation faults.
4. This Relay is a device for switching high DC voltages. If it is used for voltages exceeding the specified range, it may not be possible to interrupt the load and burning may result. In order to prevent fire spreading, use a configuration in which the current load can be interrupted in the event of emergencies.
- In order to ensure safety of the system, replace the Relay on a regular basis.
5. If the Relay is used for no-load switching, the contact resistance may increase and so confirm correct operation under the actual operating conditions.
6. With this Relay, if the rated voltage (or current) is continuously applied to the coil and contacts, and then turned OFF and immediately ON again, the coil temperature, and consequently the coil resistance, will be higher than usual. This means that the must operate voltage will also be higher than usual, exceeding the rated value (“hot start”). In this case, take the appropriate countermeasures, such as reducing the load current or restricting the energizing time or ambient operating temperature.
7. The ripple percentage for DC relays can cause fluctuations in the must-operate voltage or humming. For this reason, reduce the ripple percentage in full-wave rectified power supply circuits by adding a smoothing capacitor. Ensure that the ripple percentage is less than 5%.
8. Ensure that a voltage exceeding the specified maximum voltage is not continuously applied to the coil. Abnormal heating in the coil may shorten the lifetime of the insulation coating.
18. Confirm acceptability for safety critical applications by appropriate testing or contact Omron.
19. When a relay is used outside the recommended conditions, there is no way for Omron to predict the failure mode or results of the failure. Omron will remain blameless for the results of applying relays outside of the recommended parameters described in this catalog.
20. Durability will vary depending on the customer's usage environment and conditions. Even if the number of opening and closing cycles is small, if the product is used under complex conditions, be sure to check the actual product or contact your OMRON sales.
9. Do not use the Relay at a switching voltage or current greater than the specified maximum values. Doing so may result in arc discharge interruption failure or burning due to abnormal heating in the contacts.
10. The contact ratings are for resistive loads. The electrical endurance with inductive loads is inferior to that of resistive loads. Confirm correct operation under the actual operating conditions.
11. Do not use the Relay in locations where water, solvents, chemicals, or oil may come in contact with the case or terminals. Doing so may result in deterioration of the case resin or abnormal heating due to corrosion or contamination of the terminals. Also, if electrolyte adheres to the output terminals, electrolysis may occur between the output terminals, resulting in corrosion of the terminals or wiring disconnections.
12. Be sure to turn OFF the power and confirm that there is no residual voltage before replacing the Relay or performing wiring.
**5** omrRON ~~a~~
Please check each region's Terms & Conditions by region website.
## **OMRON Corporation Device & Module Solutions Company**
## **Regional Contact**
**Americas Europe** https://components.omron.com/us https://components.omron.com/eu **Asia-Pacific China** https://components.omron.com/ap https://components.omron.com.cn **Korea Japan** https://components.omron.com/kr https://components.omron.com/jp
© OMRON Corporation 2023-2025 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice.
**Cat. No. J269-E1-05** 1025 (0823)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.