Image not available
Illustrative purposes only
G7L-2A-P-CB DC12
Power Relay, DPST-NO, 12 VDC, 20 A, G7L Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON ELECTRONIC COMPONENTS
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 12VDC
- Product Range: G7L Series
- Relay Mounting: Through Hole
- Coil Resistance: 75ohm
- Contact Current: 20A
- Relay Terminals: PC Pin
- Contact Material: Silver Tin Indium
- Contact Voltage VAC: 220V
- Contact Voltage VDC: -
- Contact Configuration: DPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 11.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **General Purpose Relay G7L** - Ideally suited for high-inrush fluid pump controls: pool/spa, water processing, emergency, chemical industry, etc. - High-capacity, high-withstand voltage relay with no contact chattering for momentary voltage drops up to 50% of rated voltage. - UL Class B construction standard. - Wide-range AC-activated coil that handles 100 to 120 VAC at either 50 or 60 Hz. - Miniature hinge for maximum switching capacity, particularly for inductive loads. - Flame resistant materials (UL94V-0-qualifying) used for all insulation material. - Quick-connect, screw, and PCB terminals available. - Standard models are UL, CSA, and TUV approved; VDE/IEC 950 versions are now available. Meet pollution degree 3, Material Group II & III. ## **Orderin Information g** To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB- _AC100/120_ ). |**Type**<br>~~ee~~|**Contact form**<br>~~ee~~|**Model**<br>~~ee~~<br>~~ee~~|**Model**<br>~~ee~~<br>~~ee~~|**Model**<br>~~ee~~<br>~~ee~~| |---|---|---|---|---| |||**Quick-connect terminal**<br>~~ee~~<br>~~ee~~|**Screw terminal**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**PCB terminal**<br>~~ee~~<br>~~ee~~| |E bracket (see note 1)<br>~~en~~|SPST-NO<br>~~en~~|**G7L-1A-T-CB**<br>~~en~~<br>~~ee~~|**G7L-1A-B-CB**<br>~~ee~~<br>~~en~~<br>~~ee~~|**—**<br>~~en~~<br>~~ee~~| ||DPST-NO<br>~~en~~|**G7L-2A-T-CB**<br>~~en~~<br>~~ee~~<br>~~es ee~~|**G7L-2A-B-CB**<br>~~en~~<br>~~ee~~<br>~~ee~~|**—**<br>~~en~~<br>~~ee~~| |E bracket (see note 1)<br>(with test button)<br>~~ee~~|SPST-NO<br>~~ee~~|**G7L-1A-TJ-CB**<br>~~ee~~<br>~~ee~~<br>~~es ee~~|**G7L-1A-BJ-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~<br>~~ee~~| ||DPST-NO<br>~~ee~~|**G7L-2A-TJ-CB**<br>~~ee~~<br>~~es ee~~<br>~~es ee~~|**G7L-2A-BJ-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~| |Upper bracket<br>~~ee~~|SPST-NO<br>~~ee~~|**G7L-1A-TUB-CB**<br>~~es ee~~<br>~~ee~~<br>~~es ee~~|**G7L-1A-BUB-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~| ||DPST-NO<br>~~ee~~|**G7L-2A-TUB-CB**<br>~~ee~~<br>~~es ee~~<br>~~es ee~~|**G7L-2A-BUB-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~| |Upper bracket<br>(with test button)<br>~~ee~~|SPST-NO<br>~~ee~~|**G7L-1A-TUBJ-CB**<br>~~es ee~~<br>~~ee~~<br>~~es ee~~|**G7L-1A-BUBJ-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~| ||DPST-NO<br>~~ee~~|**G7L-2A-TUBJ-CB**<br>~~ee~~<br>~~es ee~~<br>~~ee~~|**G7L-2A-BUBJ-CB**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**—**<br>~~ee~~| |PCB mounting<br>~~es~~|SPST-NO<br>~~es~~|**—**<br>~~es ee~~<br>~~es~~<br>~~ee~~|**—**<br>~~ee~~<br>~~es~~<br>~~ee~~|**G7L-1A-P-CB**<br>~~es~~| ||DPST-NO<br>~~es~~|**—**<br>~~es~~<br>~~ee~~|**—**<br>~~es~~<br>~~ee~~|**G7L-2A-P-CB**<br>~~es~~| General Purpose Relay **G7L** 305 ## ■ **Model Number Legend** **G7L-** ❏❏ **-** ❏❏❏❏ - **1 2 3 4 5 6** **1. Contact form** - 1A:SPST-NO - 2A:DPST-NO ## **3. Mounting construction** No symbol:E bracket type UB:Upper bracket type **5. 80: VDE approved version** (includes UL, CSA and TÜV) ## **6. CB: Class B insulation** ## **2. Terminal shape** - T:Quick-connect terminals P:PCB terminals **4. Special functions** No symbol:Without test button J:With test button **7. Rated coil voltage** - B:Screw terminals ## ■ **Accessories** **Quick-connect Terminals** |**Description**<br>~~—~~|**Model**<br>~~—~~|**Model**<br>~~—~~|**Model**<br>~~—~~|**Model**<br>~~—~~|**Model**| |---|---|---|---|---|---| ||**Contact form**<br>~~—~~||||| ||**SPST-NO**<br>~~—~~||**DPST-NO**||| |E-brackets<br>~~—~~|G7L-1A-T<br>~~—~~|G7L-1A-TJ|G7L-2A-T|G7L-2A-TJ|**R99-07G5D**| |Track mountingadaptor<br>~~—~~|||||**P7LF-D**| |Front connectingsocket<br>~~—~~|||||**P7LF-06**| |**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Description**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-T<br>G7L-1A-TJ<br>G7L-2A-T<br>G7L-2A-TJ<br>Track mountingadaptor<br>Front connectingsocket<br>~~—~~|**Model**<br>**R99-07G5D**<br>**P7LF-D**<br>**P7LF-06**|**Model**<br>**R99-07G5D**<br>**P7LF-D**<br>**P7LF-06**| |---|---|---|---|---|---|---|---|---|---|---| |**Note:**A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.<br>~~—~~|||||||||A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.|| |**Screw Terminals**||||||||||| |**Note:**The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.<br>**Specifications**<br>■**Contact Data**<br>**Description**<br>**Model**<br>**Model**<br>**Contact form**<br>**SPST-NO**<br>**DPST-NO**<br>E-brackets<br>G7L-1A-B<br>G7L-1A-BJ<br>G7L-2A-B<br>G7L-2A-BJ<br>**R99-07G5D**<br>Track mountingadaptor<br>**P7LF-D**<br>Terminal Cover<br>**P7LF-C**<br>~~—|~~||||||||||| |**Load**<br>**G7L-1A-T, G7L-1A-B**|**G7L-1A-T, G7L-1A-B**||**G7L-2A-T, G7L-2A-B**|**G7L-2A-T, G7L-2A-B**|||||**G7L-1A-P, G7L-2A-P**|| |**Resistive load**|**Inductive load**||**Resistive load**|**Inductive load**|||**Resistive load**<br>**Inductive load**|||| |**(cos**φ**= 1)**|**(cos**φ**= 0.4)**||**(cos**φ**= 1)**|**(cos**φ**= 0.4)**||**= 0.4)**||**(cos**φ**= 1)**||**(cos**φ**= 0.4)**| |**Rated load**<br>30 A, 220 VAC|25 A, 220 VAC||||||20 A, 220 VAC|20 A, 220 VAC|20 A, 220 VAC|| |**Contact material**<br>AgSnIn||||||||||| |**Carry current**<br>30 A|||25 A||||20 A|20 A||| |**Max. operating voltage**<br>250 VAC||||||||||| |**Max. operating current**<br>30 A|||25 A||||20 A|20 A||| |**Max. switching capacity** 6,600 VA|5,500 VA||||||4,400 VA||4,400 VA|| |**Min. permissible load**<br>100 mA, 5 VDC (please inquire for lower minimum rating)||||||||||| **Note:** P level: λ 60 = 0.1 x 10[-6] operation. ## ■ **Coil Internal Circuit** **DC operating coil AC operating coil** General Purpose Relay **G7L** 306 ## ■ **Coil Data** ## **AC** **Rated voltage Rated current Resistance Must operate Must release Max. voltage Power (V) (mA) (** Ω **) % of rated voltage consumption** 6 283 18.90 75% max. 15% min. 110% max. Approx.1.70 12 142 75 to 2.50 VA 24 71 303 50 34 1,310 100/120 17.00/20.40 5,260 75 volts 18 volts 132 volts 200/240 8.50/10.20 21,000 150 volts 36 volts 264 volts **DC Rated voltage Rated current Resistance Must operate Must release Max. voltage Power (V) (mA) (** Ω **) % of rated voltage consumption** 6 317 18.90 75% max. 15% min. 110% max. Approx.1.90 W 12 158 75 24 79 303 48 40 1,220 100 19 5,260 ~~==~~ **Note: 1.** The rated current and coil resistance are measured at a coil temperature of 23 ° C (73 ° F) with tolerances of +15%/-20% for AC rated current and ± 15% for DC coil resistance. **2.** Performance characteristic data are measured at a coil temperature of 23 ° C (73 ° F). ## ■ **Characteristics** |■**Characteristics**|■**Characteristics**|| |---|---|---| |**Contact resistance**||50 mΩmax.| |**Operate time**||30 ms max.| |**Release time**||30 ms max.| |**Max. operating**<br>**frequency**|**Mechanical**|1,800 operations/hour| ||**Electrical**|1,800 operations/hour(under rated load)| |**Insulation resistance**||1,000 MΩmin.(at 500 VDC)| |**Dielectric strength**||4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts| |||2,000 VAC, 50/60 Hz for 1 minute between contacts of samepole| |||2,000 VAC, 50/60 Hz for 1 minute between contacts of differentpoles(DPST-NO type)| |**Impulse withstand voltage**||Between coil and contact: 10,000 V min./12,000 V typ.(impulse wave used: 1.20 x 50μs)| |**Vibration**|**Mechanical**<br>**durability**|10 to 55 Hz; 1.50 mm (0.06 in) double amplitude| ||**Malfunction**<br>**durability**|10 to 55 Hz; 1.50 mm (0.06 in) double amplitude| |**Shock**|**Mechanical**<br>**durability**|1,000 m/s2(approx. 100 G)| ||**Malfunction**<br>**durability**|1,000 m/s2(approx.10 G)| |**Life expectancy**|**Mechanical**|1,000,000 operations min. (at 1,800 operations/hour)| ||**Electrical**|100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)| |**Ambient temperature**||-25°to 60°C (-13°to 140°F)| |**Humidity**||35% to 85% RH| |**Weight**||Quick-connect terminal type: approx. 90g(3.17 oz)| |||PCB terminal type: approx. 100g(3.52 oz)| |||Screw terminal type: approx. 120g(4.23 oz)| **Note:** Data shown are of initial value. General Purpose Relay **G7L** 307 ## ■ **Characteristic Data** ## **Maximum switching capacity** **==> picture [119 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> 3020<br>AC inductive load<br>(cosy = 0.4)<br>5enea SCsO OO<br>se |<br>ia<br>1LE<br>10 30 50 70 100<br>Switching voltage (V)<br>Switching current (A)<br>**----- End of picture text -----**<br> ## **Electrical service life** **==> picture [126 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> 1.000PT Sf<br>EAS 220 VAC resistive load<br>700 LAN 7 i<br>s00f<br>300TNNN.<br>20VRC<br>rofeone 2) |<br>50 6 a 5 RRND10.15 OC<br>Switching current (A)<br>operations)<br>3<br>Service life (x 10<br>**----- End of picture text -----**<br> ## **Dimensions** Unit: mm (inch) ## ■ **Relays** ## **G7L-1A-T (E Bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-2A-T (E Bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) * E bracket must be ordered separately. General Purpose Relay **G7L** 308 **G7L-1A-TJ (E Bracket Attached)*** ## **Terminal arrangement/ Internal connections** (Top view) ## **Mounting holes** (Bottom view) ## **G7L-2A-TJ** ## **(E Bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-1A-TUB** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-2A-TUB** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) *E bracket must be ordered separately. General Purpose Relay **G7L** 309 Unit: mm (inch) ## **G7L-1A-TUBJ** **Terminal arrangement/ Internal connections** (Top view) ## **Mounting holes** (Bottom view) ## **G7L-2A-TUBJ** **Terminal arrangement/ Internal connections** (Top view) ## **Mounting holes** (Bottom view) ## **G7L-1A-B** ## **(E bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) ## **Mounting holes** (Bottom view) ## **G7L-2A-B** ## **(E bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) — **Mounting holes** (Bottom view) - E bracket must be ordered separately. General Purpose Relay **G7L** 310 **G7L-1A-BJ (E bracket Attached)*** ## **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-2A-BJ (E bracket Attached)*** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-1A-BUB** **==> picture [86 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal arrangement/<br>Internal connections<br>(Top view)<br>**----- End of picture text -----**<br> **Mounting holes** (Bottom view) ## **G7L-2A-BUB** **Terminal arrangement/ Mounting holes Internal connections** (Bottom view) (Top view) - E bracket must be ordered separately. General Purpose Relay **G7L** 311 Unit: mm (inch) ## **G7L-1A-BUBJ** **Terminal arrangement/ Internal connections** (Top view) ## **Mounting holes** (Bottom view) ## **G7L-2A-BUBJ** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-1A-P** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) ## **G7L-2A-P** **Terminal arrangement/ Internal connections** (Top view) **Mounting holes** (Bottom view) **==> picture [30 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> 4<br>**----- End of picture text -----**<br> General Purpose Relay **G7L** 312 ## ■ **Accessories** ## **E bracket R99-07G5D** **Mounting holes** (Bottom view) ## **Adaptor P7LF-D** **Mounting holes** (Bottom view) ## **Front connecting socket P7LF-06** **Mounting holes** (Bottom view) **Note: 1.** To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket. **2.** The P7LF-06 is panel or track mountable. General Purpose Relay **G7L** 313 Unit: mm (inch) ## **Cover P7LF-C** **Note:** P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals. ## **Mounting track** **==> picture [425 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> PFP-100N, PFP-50N PFP-100N2<br>(Conforming to EN 50022) (Conforming to EN 50022)<br>ee<br>— =<br>— =S— 16<br>7.3±0.15<br>4.5<br>4.5 a | a | a<br>PoEP ytPt 35±0.3 ee 27±0.15 35±0.3 [27 ] 24 am] 29.2<br>ee 15 25 10 25 1000 (500)* a 25 10 25 * | 15 (5) 1 PE 15 25 tt 10 25 1000±4 re 25 10 25 15 | 1 1.5<br>* The figure in parenthesis is for PFP-50N.<br>**----- End of picture text -----**<br> **Note: 1.** It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used. **2.** L = Length PFP-100N L = 1 m (39.00 in) PFP-50N L = 50 cm (19.60 in) PFP-100N2 L = 1 m (39.00 in) ## **End plate PFP-M** ## **Spacer** ## **PFP-S** General Purpose Relay **G7L** 314 ## ■ **Approvals** **UL Recognized (File No. E41643) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40** ° **C** |**Type**|**Contact form**|**Terminal type**|**Contact ratings**| |---|---|---|---| |G7L-1A-T-CB<br>G7L-1A-TJ-CB<br>G7L-1A-TUB-CB<br>G7L-1A-TUBJ-CB|SPST-NO|Quick-connect|30 A, 277 VAC, General Use, 100,000 ops<br>1.5 kW, 120 VAC, Tungsten, 6,000 ops<br>1.5 HP, 120 VAC, 6,000 ops<br>3 HP, 277 VAC, 6,000 ops<br>20 FLA/120 LRA, 120 VAC, 30,000 ops<br>17 FLA/102 LRA, 265 VAC, 30,000 ops<br>TV-10, 120 VAC, 25,000 ops| |G7L-1A-B-CB<br>G7L-1A-BJ-CB<br>G7L-1A-BUB-CB<br>G7L-1A-BUBJ-CB||Screw|| |G7L-1A-P-CB||PCB|| |G7L-2A-T-CB<br>G7L-2A-TJ-CB<br>G7L-2A-TUB-CB<br>G7L-2A-TUBJ-CB|DPST-NO|Quick-connect|| |G7L-2A-B-CB<br>G7L-2A-BJ-CB<br>G7L-2A-BUB-CB<br>G7L-2A-BUBJ-CB||Screw|| |G7L-2A-P-CB||PCB|| **Note:** Contact Omron for actual ratings marked on G7L relays ## **TÜV (File No. R9251551)** |**Type**|**Contact form**|**Coil ratings**|**Terminal type**|**Contact ratings**| |---|---|---|---|---| |G7L-1A-T-CB<br>G7L-1A-TJ-CB<br>G7L-1A-TUB-CB<br>G7L-1A-TUBJ-CB|SPST-NO|6, 12, 24, 48,<br>100, 110, 200,<br>220 VDC|Quick-connect|25 A, 240 VAC, (cosφ= 1)| |||||25 A, 240 VAC, (cosφ= 0.4)| |G7L-1A-B-CB<br>G7L-1A-BJ-CB<br>G7L-1A-BUB-CB<br>G7L-1A-BUBJ-CB||12, 24, 50,<br>100/120, 200/240<br>VAC|Screw|30 A, 240 VAC, (cosφ= 1)| |||||25 A, 240 VAC, (cosφ= 0.4)| |||||30 A, 240 VAC, (cosφ= 0.4)| |G7L-1A-P-CB|||PCB|20 A, 240 VAC, (cosφ= 1)| |||||20 A, 240 VAC, (cosφ= 0.4)| |G7L-2A-T-CB<br>G7L-2A-TJ-CB<br>G7L-2A-TUB-CB<br>G7L-2A-TUBJ-CB|DPST-NO||Quick-connect|25 A, 240 VAC, (cosφ= 1)| |||||25 A, 240 VAC, (cosφ= 0.4)| |G7L-2A-B-CB<br>G7L-2A-BJ-CB<br>G7L-2A-BUB-CB<br>G7L-2A-BUBJ-CB|||Screw|25 A, 240 VAC, (cosφ= 1)| |||||25 A, 240 VAC, (cosφ= 0.4)| |G7L-2A-P-CB|||PCB|20 A, 240 VAC, (cosφ= 1)| |||||20 A, 240 VAC, (cosφ= 0.4)| ## **VDE recognized type (Licence no. 1530 UG)** **Note: 1.** Please consult OMRON for details of VDE approvals. **2.** The G7L relay conforms to the following standards: Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83 DIN VDE 0435 Teil 201 A1/05. 90 DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81 DIN EN 60 950/VDE 0805/11. 93 EMC: prEN 50082-2, EN 55022 **3.** The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics individually defined in this catalog. **4.** In the interest of product improvement, specifications are subject to change. **5.** Suffix T130 rated at 130 ° C **6.** Pollution degree 3, Material Group II & III. General Purpose Relay **G7L** 315 ## **Precautions** ## ■ **Handling** - To preserve initial performance, do not drop or otherwise subject the power relay to shock. - The case is not designed to be removed during normal handling and operation. Doing so may affect performance. - Use the power relay in a dry environment free from excessive dust, SO2, H2S, or organic gas. - Do not allow a voltage greater than the maximum allowable coil voltage to be applied continuously. ## ■ **Operating Coil** - As a rule, either a battery or a DC power supply with a maximum 5% ripple is used for the operating voltage for DC relays. Before using a rectified AC supply, confirm that the ripple is not greater than 5%. Ripple greater than this can lead to variations in the operating and reset voltages. As excessive ripple can generate beats, the insertion of a smoothing capacitor is recommended as shown below. - Do not use the power relay outside of specified voltages and currents. - Do not allow the ambient operating temperature to exceed the specified limit. ## ■ **Installation** - Although there are not specific limits on the installation site, it should be as dry and dust-free as possible. - PCB terminal-equipped relays weigh approximately 100 g. Be sure that the PCB is strong enough to support them. We recommend dual-side through-hole PCBs to reduce solder cracking from heat stress. - Quick-connect terminals can be connected to fast on receptacle #250 and positive-lock connectors. - Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force. ## ■ **Cleaning PCB Terminals** - PCB terminals have semi-sealed construction which prevents flux from entering the relay base. It is recommended that the user should apply a tape seal over the vent hole prior to wave soldering or cleaning. The tape should then be removed after processing. - When driving a transistor, check the leakage current and connect a bleeder resistor if necessary. - Momentary voltage drops on coil input voltage should not exceed one second duration after contact mating with no shock or vibration. ## ■ **Applications** - Compressors for package air conditioners and heater switching controllers - Switching controllers for power tools or motors - Power controllers for water heaters - Power controllers for dryers - Lamp control, motor drivers, and power supply switching in copy machines, facsimiles, and other OA equipment - Lighting controllers - Power controllers for packers or food processing equipment - Magnetron control in microwaves ## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.** To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. General Purpose Relay **G7L** 316 ## **Read and Understand This Catalog** Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## **Warranty and Limitations of Liability** ## **WARRANTY** OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ## **LIMITATIONS OF LIABILITY** OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. **Application Considerations SUITABILITY FOR USE** OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. **PROGRAMMABLE PRODUCTS** OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. **Disclaimers CHANGE IN SPECIFICATIONS** Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. ~~_~~ **DIMENSIONS AND WEIGHTS** Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. **PERFORMANCE DATA** Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. **ERRORS AND OMISSIONS** The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. ~~a~~ **OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS** • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com **OMRON CANADA, INC. • HEAD OFFICE OMRON ARGENTINA • SALES OFFICE** Toronto, ON, Canada • 416.286.6465 • 866.986.6766 Cono Sur • 54.11.4783.5300 www.omron247.com **OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE OMRON CHILE • SALES OFFICE** São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br Santiago • 56.9.9917.3920 **OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE OTHER OMRON LATIN AMERICA SALES** Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com 54.11.4783.5300 **OMRON EUROpE B.V.** Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu J J055-E3-04 06/09 Note: Specifications are subject to change. © 2010 Omron Electronics LLC
Updated at April 1, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →