G6RN-1-DC6
Power Relay, Miniature, SPDT, 6 VDC, 8 A, G6RN Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 6VDC
- Product Range: G6RN Series
- Relay Mounting: Through Hole
- Coil Resistance: 164ohm
- Contact Current: 8A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 120 |
| Price | 2.17 € |
| Current stock | 100+ |
| Lead time | 30 days |
G6RN PCB Power Relay **==> picture [546 x 731] intentionally omitted <==** **----- Start of picture text -----**<br> Miniature Power Relay for<br>Switching 8 A<br>• Low-profile height of 15 mm (approx. 60% the height of the Omron<br>G2R model).<br>• Capable of switching with 8 A at 250 VAC despite its small size.<br>• High sensitivity with 220mW power consumption.<br>• Offers high insulation with insulation distance of 8 mm and impulse<br>withstand voltage of 10kV between coil and contacts.<br>• Satisfies ambient operating temperature requirement of 85°C.<br>• Standard model conforms to VDE standards.<br>RoHS Compliant<br>■ Model Number Legend ■ Application Examples<br>G6RN- @@ • Control equipments<br>—1 —2 ■ Characteristics G<br>1. — Number of Poles 2. Contact Form 6<br>R<br>1: 1-pole None: SPDT (1c) Contact resistance *1 100 m Ω max. N<br>A: SPST-NO (1a) Operate time _F 15 ms max.<br>Release time 5 ms max.<br>■ Ordering Information Insulation resistance *2Between 1,000 M Ω min.<br>coil and 4,000 VAC, 50/60 Hz for 1 min<br>Classification Enclosure rating Contact form Terminal shape Model Rated coil voltage packinMinimun g unit Dielectric contactsBetween<br>5, 6, 12 VDC strength contacts of<br>SPST-NO (1a) G6RN-1A 1,000 VAC, 50/60 Hz for 1 min<br>PCB 24 VDC the same<br>Standard Fully sealed terminals 5, 6, 12 VDC 20 pcs/tube polarity<br>SPDT (1c) G6RN-1<br>24 VDC Impulse withstand<br>voltage (between coil 10,000 V (1.2 x 50 μ s)<br>Note. When ordering, add the rated coil voltage to the model number. and contacts)<br>Example: G6RN-1A DC5 Between<br>[a] =e Rated coil voltage Insulation coil and Clearance: 8 mm,<br>However, the notation of the coil voltage on the product case will be marked as @@ VDC. distance contacts Creepage: 8 mm<br>10 to 55 to 10 Hz, 0.75 mm<br>Destruction single amplitude<br>■ Ratings Vibration (10 to 55 to 10 Hz1.5 mm double amplitude)<br>● Coil resistance NO: 0.75 mm single amplitude<br>Malfunction (1.5 mm double amplitude)<br>Item Must operate Must release Max. NC: 0.4 mm single amplitude<br>Rated Coil Power<br>voltage voltage voltage (0.8 mm double amplitude)<br>current resistance (V) (V) (V) consumption Destruction 1,000 m/s [2]<br>(mA) ( Ω ) (mW) Shock<br>Rated voltage % of rated voltage resistance Malfunction NO: 100 m/s [2]<br>5 VDC 43.9 114 NC:: 50 m/s [2]<br>12 VDC6 VDC 18.336.6 655164 70% max. 10% min. (at 23°C)150% Approx. 220 Mechanical 10,000,000 operations min. (at 36,000 operations/hr)<br>— 24 VDC 9.2 2,620 50,000 operations min.<br>(8 A at 250 VAC, resistive load)<br>Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of±10%. Durability Electrical *3 50,000 operations min. (5 A at 30 VDC, resistive load)<br>*2. The operating characteristics are measured at a coil temperature of 23°C. (at 360 operations/hr under<br>*3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. rated load)<br>● Contacts Failure rate (P level) 10 mA at 5 VDC<br>(reference value) *4<br>Load Resistive load Ambient operating -40°C to 85°C (with no icing or<br>Item temperature condensation)<br>Contact type Single Ambient operating 5% to 85%<br>Contact material Ag-Alloy + gold plating humidity<br>(Cd free) Weight Approx. 9 g<br>8 A at 250 VAC<br>Rated load Note. The data given above are initial values.<br>5 A at 30 VDC<br>*1. Measurement conditions: 5 VDC, 1 A, voltage drop<br>Rated carry 8 A method.<br>current *2. Measurement conditions: The insulation resistance<br>Max. switching 250 VAC, 30 VDC was measured with a 500 VDC megohmmeter at the<br>voltage same locations as the dielectric strength was<br>Max. switching 8 A measured.<br>current *3. Test conditions: With diode<br>*4. This value was measured at a switching frequency of<br>120 operations/min.<br>aaa<br>1<br>**----- End of picture text -----**<br> G6RN **PCB Power Relay** ## ■ **Engineering Data** ## ● **Maximum Switching Capacity** ## ● **Durability** **==> picture [154 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> ● Ambient Temperature vs.<br>Maximum Coil Voltage<br>200<br>180<br>160<br>150<br>140<br>130<br>120<br>110<br>100<br>80<br>0<br>-40 20 23 30 0 40 50 60 70 80 90 100<br>Ambient Temperature (°C)<br>Note. The maximum coil voltage refers to the<br>maximum value in a varying range of operating<br>power voltage, not a continuous voltage.<br>Maximum coil voltage (%)<br>**----- End of picture text -----**<br> **==> picture [466 x 346] intentionally omitted <==** **----- Start of picture text -----**<br> 100 200<br>250 VAC resistive load<br>50 30 VDC resistive load<br>30 50 180<br>10 DC resistive load AC resistive load 30 160<br>8 150<br>5<br>140<br>3 10 130<br>120<br>1 5 110<br>0.5 3 100<br>0.3<br>80<br>0.1 0 3 5 10 30 50 100 250 500 10 2 4 6 8 10 -40 20 23 30 0 40<br>Switching Voltage (V) Switching Current (A)<br>Note.<br>● Ambient Temperature vs. ● Shock Malfunction<br>Maximum Coil Voltage G6RN-1<br>100 Sample: G6RN-1 12 VDC Must operate voltageMust release voltage contact A Y 1,000 Sample: G6RN-1 24 VDCNumber of Relays: 5 pcs<br>G 80 Number of Relays: 5 pcs Test conditions: The value at which<br>6 max. X Z malfunction occurred was measured<br>R X 1,000 1,000 after applying shock to the test piece 3<br>N 60 min. contact B [88.2] times each in 6 directions along 3 axes.Standard value: 100m/s50m/s [2] at contact B [2] at contact A,<br>40<br>1,000 1,000<br>Z' X'<br>max.<br>X<br>20 min. Shock direction<br>X X'<br>1,000 Unit: m/s [2] Y<br>Y' Z<br>0 Z'<br>-40 -20 0 20 40 60 80 100<br>Y'<br>Ambient Temperature (°C)<br>4 operations)<br>Switching current (A) Maximum coil voltage (%)<br>Durability (x 10<br>Operate/Release voltage (percentage of rated value) (%)<br>**----- End of picture text -----**<br> ## ■ **Dimensions** **==> picture [512 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> G6RN-1 PCB Mounting Holes Terminal Arrangement/<br>(Bottom View) Internal Connections<br>10 [±0.5] (Bottom View)<br>28.5 [±0.5] Five, 1.3-dia. holes<br>(1.19) 1 2<br>15 [±0.5] 3.5 7.62 [±0.1]<br>0.5<br>(1.19) 5 4 3<br>1 9 3.2 3.2 7.62 (1.6) 19 [±0.1] 3.2 [±0.1] 3.2 [±0.1] (1.5) (No coil polarity)<br>G6RN-1A PCB Mounting Holes Terminal Arrangement/<br>(Bottom View) Internal Connections<br>28.5 [±0.5] 10 [±0.5] Four, 1.3-dia. holes (Bottom View)<br>(1.19) 1 2<br>15 [±0.5] 3.5 7.62 [±0.1]<br>0.5<br>(1.19) 5 3<br>19 5. 1 7.62 (1.6) 19 [±0.1] 5.1 [±0.1] (2.8) (No coil polarity)<br>**----- End of picture text -----**<br> **2** G6RN **PCB Power Relay** G 6 R N ## ■ **Approved Standards** - The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. - **UL Recognized** (File No. E41515) **CSA Certified** (File No. 31928) |Model<br>Number<br>poles|of|Coil ratings|||Contact ratings|Number of test<br>operations|| |---|---|---|---|---|---|---|---| |G6RN-1<br>1||5 to 24 VDC||8 A, 250 VAC 85°C<br>8 A, 30 VDC 85°C||6,000|| |**EN/TÜV Certified**|(Certificate No. 6135)||||||| |Model<br>Number<br>poles|of|Coil ratings|||Contact ratings|Approved switching<br>operations|| |G6RN-1<br>G6RN-1A<br>1||5, 6, 12, 24 VDC||8 A, 250 VAC (Resistive)<br>85°C||10,000|| ||||||||| |**Creepage distance**|||||8 mm||| |**Clearance distance**|||||8 mm||| |**Insulation material group**|||||IIIa||| |**Rated Insulation voltage**|||||250 V||| |**Pollution degree**|||||2||| |**Rated voltage system**|||||250 V||| |**Overvoltage category**|||||III||| |**Tracking Index of relay base**|||||PTI 250 V min. (housing|parts)|| |**Flammability class according to UL94**|||||V-0||| |**Ball pressure test (IEC 60695-10-2)**|||||160°C||| ## ■ **Precautions** - **Please refer to “PCB Relays Common Precautions” for correct use.** - Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. - Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. **Note: Do not use this document to operate the Unit.** **OMRON Corporation Electronic and Mechanical Components Company** **Contact: www.omron.com/ecb** **Cat. No. J182-E1-04** 1116(0207)(O) **3**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →