Image not available
Illustrative purposes only
G6RL-14-ASI-DC6
Power Relay, SPDT, 6 VDC, 8 A, G6RL Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 6VDC
- Product Range: G6RL Series
- Relay Mounting: Through Hole
- Coil Resistance: 163ohm
- Contact Current: 8A
- Relay Terminals: PC Pin
- Contact Material: Silver Tin Indium
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 300 |
| Price | 5.25 € |
| Current stock | 100+ |
| Lead time | 30 days |
G6RL PCB Power Relay G 6 R L ## **Low-profile 12.3 mm height power relay with maximum switching of 10A** - Low profile: 12.3 mm in height - Max. switching capacity: 2,500 VA (NO) - Dielectric strength: 5 kV - Clearance and creepage distance: 10 mm. - Models with high shock resistance (250 m/s[2] ) are available. - Models for P1 load (2 x 200 W lamps parallel to ignition transformer) are available. ## **RoHS Compliant** ## ■ **Model Number Legend** ## **G6RL-** @ @ @ - @ - @ ~~TTT~~ 1 2 3 4 5 **1. Number of Poles 4. Contact material** 1: 1-pole None: Standard (Ag-alloy, Cd free) **2. Contact Form** ASI: AgSnIn None: SPDT (1c) **5. Special Functions** A: SPST-NO (1a) PL: P1 load ## ■ **Application Examples** • Boilers ~~—EEEE~~ - PLCs - I/O ports - Timers - Temperature controllers ## **3. Enclosure rating** None: Flux protection - 4: Fully sealed ## ■ **Ordering Information** |**Classification**|**Terminal Shape**|**Contact form**|**Enclosure rating**|**Model**|**Rated coil voltage**|**Minimum packing unit**| |---|---|---|---|---|---|---| |Standard|PCB terminals|SPST-NO (1a)|Flux protection|**G6RL-1A**<br>**G6RL-1A-ASI**|3 VDC<br>5 VDC<br>6 VDC<br>12 VDC<br>24 VDC<br>48 VDC|100 pcs/tray| |P1 Load||||**G6RL-1A-ASI-PL**||| |Standard|||Fully sealed|**G6RL-1A4-ASI**||| |||SPDT (1c)|Flux protection|**G6RL-1**<br>**G6RL-1-ASI**||| |P1 Load||||**G6RL-1-ASI-PL**||| |Standard|||Fully sealed|**G6RL-14-ASI**||| Note. When ordering, add the rated coil voltage to the model number . Example: G6RL-1A DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@VDC. ## ■ **Ratings** ## ● **Coil** ## **Standard, P1 Load (-PL type)** |**Rated Voltage**<br>**(VDC)**|**Rated current**<br>**(mA)**|**Coil resistance**<br>**(**Ω**)**|**Must operate voltage**<br>**(V)**|**Must release voltage**<br>**(V)**|**Max. voltage**<br>**(V)**|**Power consumption**<br>**(mW)**| |---|---|---|---|---|---|---| ||||**% of rated voltage**|||| |**3**|73.3|40|70% max.|10% min.|150%<br>(at 23°C)|Approx. 220| |**5**|44|113||||| |**6**|36.7|163||||| |**12**|18.3|654||||| |**24**|9.2|2618||||| |**48**|5|9600||||Approx. 240| Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. **1** **PCB Power Relay** G 6 R L ## G6RL ## ● **Contacts** |||| |---|---|---| |**Contact resistance *1**||100 mΩmax.| |**Operate time**||10 ms max.| |**Release time**||5 ms max.| |**Insulation resistance *2**||1,000Ωmin.| |**Dielectric strength**|**Between coil and contacts**|5,000 VAC, 50/60 Hz for 1 min| ||**Between contacts of the same polarity**|1,000 VAC, 50/60 Hz for 1 min| |**Impulse withstand voltage**|**Between coil and contacts**|10kV (1.2×50μs)| |**Insulation distance**|**Between coil and contacts**|Clearance: 10 mm, Creepage: 10 mm| |**Vibration resistance**|**Destruction**|10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)| ||**Malfunction**|10 to 55 to 10 Hz, 0.825 mm single amplitude (1.65 mm double amplitude) when energized<br>10 to 55 to 10 Hz, 0.4 mm single amplitude (0.8 mm double amplitude) when de-energized.| |**Shock resistance**|**Destruction**|1,000 m/s2| ||**Malfunction**|NO: 200 m/s2, NC: 50 m/s2| |**Endurance**|**Mechanical**|10,000,000 operations min. (at 18,000 operations/h)| ||**Electrical**|G6RL-1(A)<br>50,000 operations min. (NO) at 250 VAC, 8A (resistive load)<br>50,000 operations min. (NC) at 250 VAC, 8A (resistive load)<br>50,000 operations min. at 24 VDC, 5A (resistive load)<br>(at 600 operations/h)<br>G6RL-1(A)-ASI-(PL)<br>100,000 operations min. (NO) at 250 VAC, 10A (resistive load)<br>100,000 operations min. at 250 VAC, 8A (resistive load)<br>50,000 operations min. at 30 VDC, 5A (resistive load)<br>(at 1,800 operations/h)<br>G6RL-1(A)4-ASI<br>50,000 operations min. (NO) at 250 VAC, 8A (resistive load)<br>50,000 operations min. (NC) at 250 VAC, 8A (resistive load)<br>50,000 operations min. at 24 VDC, 5A (resistive load)<br>(at 1,800 operations/h)| |**Failure rate (P level) (reference value) *3**||10 mA at 5 VDC| |**Ambient operating temperature**||-40°C to 85°C (with no icing or condensation)| |**Ambient operating humidity**||5% to 85%| |**Weight**||Approx. 7.8 g| Note. The given values are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. - *3. This value was measured at a switching frequency of 120 operations/min. **2** G6RL **PCB Power Relay** G 6 R L ## ■ **Engineering Data** ## **G6RL-1(A)(4)-(ASI)-(PL)** ## **G6RL-1(A)(4)-(ASI)-(PL)** ## **G6RL-1(A)** **==> picture [511 x 378] intentionally omitted <==** **----- Start of picture text -----**<br> ● Maximum Switching Capacity ● Durability ● Ambient Temperature vs. Maximum<br>Coil Voltage<br>100 1,000 200<br>50 AC resistive load (N.O.) 500 250 VAC inductive load(cos φ = 0.4) 180<br>G6RL-1(220 mW)<br>DC resistive load AC resistive load (N.C.)<br>300<br>160<br>10 250 VAC resistive load (N.O.) 150<br>5 140<br>100<br>120<br>1 50 24 VDC resistive load<br>100<br>0.5 30<br>80<br>0.1 10 60<br>1 3 5 10 30 50 100 300 500 1,000 0 2 4 6 8 10 -40 20 23 30 40 50 60 70 80 90 100<br>Switching voltage (V) Switching current (A) Ambient temperature (°C)<br>Note The "maximum coil voltage" is the maximum<br>voltage that can be applied to the Relay coil.<br>G6RL-1(A)(4) G6RL-1(A)(4)-(ASI)-(PL)<br>● Ambient Temperature vs. Must ● Shock Malfunction<br>Operate or Must Release Voltage<br>120 Y<br>Sample: G6RL 24 VDC Must operate voltage 980<br>Number of relays: 5 pcs Must release voltage NO contact<br>100<br>X Z<br>80 X max.min. 980 NC contact 980 Sample:Number of Relays: 5 pcsG6RL-1 24 VDC<br>Test Conditions: The value at which malfunction<br>60 occurred was measured after<br>98 294 applying shock to the test piece<br>3 times each in 6 directions<br>40 max. 980Z’ X’ along 3 axes.<br>X Standard value: 200m/s [2] (NO)<br>20 min. Shock direction 50m/s [2] (NC)<br>980 Unit: m/s [2] X’ X<br>Y’ Y Z<br>0<br>−40 −20 0 20 40 60 80 100 Z’<br>Y’<br>Ambient temperature (°C)<br>Switching current (A) 3)No. of operation (x10 Maximum coil voltage (%)<br>On the basis of rated voltage (%)<br>**----- End of picture text -----**<br> ## ■ **Dimensions** (Unit: mm) **==> picture [511 x 300] intentionally omitted <==** **----- Start of picture text -----**<br> G6RL-1A<br>G6RL-1A-ASI<br>PCB Mounting Holes Terminal Arrangement/Internal<br>G6RL-1A4-ASI (Bottom View) Connections<br>(Bottom View)<br>(2.9) 18.9±0.1 5±0.1<br>28.5 max. 10.0 max. (1.7)<br>1 2<br>5 3<br>Four, 1.3±0.1 dia. holes<br>0.4 0.24 0.4 0.8 0.8 (Indicates average<br>dimensions.)<br>G6RL-1<br>G6RL-1-ASI<br>PCB Mounting Holes Terminal Arrangement/<br>G6RL-14-ASI (Bottom View) Internal Connections<br>(Bottom View)<br>(1.5) 18.9±0.1 3.2±0.1<br>28.5 max. 10.0 max. 3.2±0.1<br>(1.7)<br>1 2<br>4 3<br>5<br>Five, 1.3±0.1 dia. holes<br>0.4 0.40.24 0.4 0.8 0.8 (Indicates average dimensions.)<br>3.2 12.3 max. 0.17.62±<br>3.2 0.17.62±<br>12.3 max.<br>**----- End of picture text -----**<br> **3** G6RL **PCB Power Relay** G 6 R L ## ■ **Approved Standards** The approval ratings for overseas models are different from the performance values determined individually. Confirm the values before use. ## ● **UL Recognized: (File No. E41643)** |**Models**|**Contact from**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |---|---|---|---|---| |G6RL-1A|SPST-NO (1a)|3 to 48 VAC|10 A, 250 VAC (NO) (Resistive) 85°C<br>8 A, 250 VAC (Resistive) 85°C<br>5 A, 30 VDC (Resistive) 85°C|6,000| |G6RL-1|SPDT (1c)|||| |G6RL-1A(4)-ASI|SPST-NO (1a)|||| |G6RL-1(4)-ASI|SPDT (1c)|||| ## ● **EN/IEC, VDE Certified: (EN61810-1) (Certificate No. C266)** |**Models**|**Contact from**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |---|---|---|---|---| |G6RL-1A-(ASI)|SPST-NO (1a)|3, 5, 6, 12, 24, 48 VDC|10 A, 250 VAC (NO) 85°C|10,000| |G6RL-1-(ASI)|SPDT (1c)||8 A, 250 VAC 85°C|30,000| ||||5 A , 30 VDC 85°C|50,000| |G6RL-1A4-ASI|SPST-NO (1a)|3, 5, 6, 12, 24, 48 VDC|10 A, 250 VAC (NO) 85°C|10,000| |G6RL-14-ASI|SPDT (1c)||8 A, 250 VAC 85°C|| ||||5 A, 30 VDC 85°C|| ## ● **EN/IEC, VDE Certified: (EN 60947-5-1) (Certificate No. C266)** |**Models**|**Contact ratings**|**Number of test operations**| |---|---|---| |G6RL-1(A)(4)|AC15 (NO)<br>AC240,<br>3 A, cosϕ0.3, Room temperaure|6,000| ||DC13<br>DC125,<br>0.22A, 165ms, Room temperaure|| ||DC13<br>DC250,<br>0.1A, 150ms, Room temperaure|| |G6RL-1(A)-ASI|AC15<br>AC240,<br>3 A, cosϕ0.3, Room temperaure|| ||DC13<br>DC125,<br>0.22A, 165ms, Room temperaure|| ||DC13<br>DC250,<br>0.1A, 150ms, Room temperaure|| |G6RL-1(A)4-ASI|AC15<br>AC240,<br>3 A, cosϕ0.3, Room temperaure|| ||DC13<br>DC125,<br>0.22A, 165ms, Room temperaure|| ## ● **EN/IEC, VDE (60947-4-1) (Certificate No. C266)** |**Models**|**Contact ratings**<br>|**Number of test operations**| |---|---|---| |G6RL-1(A)<br>G6RL-1(A)-ASI|AC1 AC250V <br>8 A 85°C<br>|6,000| ||AC3 AC250V <br>2 A 85°C<br>|| ||DC1 DC24V <br>5 A 85°C<br>|| ||DC3 DC24V <br>2 A 85°C|| ## ● **EN/IEC, VDE (EN60730-1) (Certificate No. 40021033)** |**Models**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |---|---|---|---| |G6RL-1(A)|3, 5, 6, 12, 24, 48 VDC|2 (2) A AC250V<br>65°C|100,000| |||6 (4) A (NC) AC250V<br>65°C|| |||8 (4) A (NO) AC250V<br>85°C|| |G6RL-1(A)-ASI||2 (2) A AC250V<br>65°C|| |||6 (4) A (NC) AC250V<br>65°C|| |||8 (4) A (NO) AC250V<br>85°C|| ## ● **EN/IEC** |**Models**|**CE Marking**|**Applicable Safety Category**|**Applicable Safety Category**|**Basic Requirements of Machinery Directive/Low-voltage Directive**|**Basic Requirements of Machinery Directive/Low-voltage Directive**|**Basic Requirements of Machinery Directive/Low-voltage Directive**| |---|---|---|---|---|---|---| |||||**Applicable Standard No.**||**Application Standard No.**| |G6RL|−|1||EN61810-1||−| |Note. Basic requirements of EMC directives (EMI standard No., EMS standard No., Certification Body, File No., Applicable time) … not applicable.||||||| |**Creepage distance**|||10 mm|||| |**Clearance distance**|||10 mm|||| |**Insulation material group**|||IIIa|||| |**Rated Insulation Voltage**|||250 V|||| |**Pollution degree**|||3||2|| |**Rated voltage system**|||250 V||400 V|| |**Overvoltage category**|||III||II|| |**Tracking Index of relay base**|||PTI 250 V min. (housing parts)|||| |**Flammability class according to UL94**|||V-0|||| |**Ball pressure test (IEC 60695-10-2)**|||170°C|||| **4** G6RL **PCB Power Relay** G 6 R L ## ■ **Precautions** - **Please refer to "PCB Relays Common Precautions" for correct use.** ## Correct Use - The G6RL are net intended to be used in automotive applications (including two wheel vehicles). - If the product is used in the following applications, consult your OMRON sales representative to check the necessary items according to the specification sheets. Also make sure the product is used within the specified ratings and performance ranges with an ample margin and implement safety measures, such as designing a safety circuit, to minimize danger should the product fail. - a. Outdoor use, uses involving potential chemical contamination or electrical interference. - b. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, safety equipment, and equipment that could present a risk to human life or body. - c. Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems. - Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. - Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. **Note: Do not use this document to operate the Unit.** **OMRON Corporation Electronic and Mechanical Components Company** **Contact: www.omron.com/ecb** **Cat. No. K133-E1-07** 0316(0207)(O) **5**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →