Image not available
Illustrative purposes only
G6DN-1A-SL DC5
Power Relay, SPST-NO, 5 VDC, 5 A, G6DN Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 5VDC
- Product Range: G6DN Series
- Relay Mounting: Through Hole
- Coil Resistance: 227ohm
- Contact Current: 5A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 120 |
| Price | 2.32 € |
| Current stock | 1000+ |
| Lead time | 9 days |
G6DN PCB Power Relay G 6 D N ## **SPST Slim Power Relay for 5 A switching** - Slim 5-mm width and miniature size. (20 × 5.08 × 12.5 mm) - High switching capability 5 A (250 VAC and 30 VDC), and high contact reliability by crossbar-twin contact. - Low power consumption 110 mW. - Meets application standards EN61010-1 and EN61010-2-201 for reinforced insulation (CTI 600 V min. and Rated insulation voltage 300 V). - Actualize electrical durability 100 Kops (-L type) ## ■ **Model Number Legend** ## G6DN- @@@ - @ — — — — 1 2 3 4 **1. Number of Poles 3. Enclosure Rating** 1: 1-pole None: Fully sealed None: Fully sealed ## ■ **Application Examples** - Programmable Controller output - Temperature Controller - Building Automation - Output of control system **2. Contact Form 4. Classification** A: SPST-NO (1a) None: Standard (E-LIFE 80 Kops) L: High durability type (E-LIFE 100 Kops) SL: General purpose ## ■ **Ordering Information** |Classification|Contact form|Enclosure rating|Terminal shapes|Model|Minimum packing unit| |---|---|---|---|---|---| |Standard|SPST-NO (1a)|Fully sealed|PCB terminal|G6DN-1A|25 pcs/ tube| |High durability||||G6DN-1A-L|| |General purpose||||G6DN-1A-SL|100pcs/tray| Note. When ordering, add the rated coil voltage to the model number. Example: G6DN-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packaging will be marked as @@ VDC. Example: G6DN-1A 5VDC ## ■ **Ratings** ## ● **Coil** |Classification<br>Rated voltage|Classification<br>Rated voltage|Rated current<br>(mA)|Coil resistance<br>(Ω)|Must operate voltage (V)|Must release voltage (V)|Max. voltage (V)|Power consumption<br>(mW)| |---|---|---|---|---|---|---|---| |||||% of rated voltage|||| |Standard|4.5 VDC|24.4|184|70% max. *|5% min.|160%|Approx. 110| ||5 VDC|22.0|227||||| ||12 VDC|9.2|1,309||||| ||24 VDC|4.6|5,236||||| |High durability|5 VDC|36.0|139||||Approx. 180| ||12 VDC|15.0|800||||| ||24 VDC|7.5|3,200||||| |General purpose|5 VDC|22.0|227||||Approx. 110| ||12 VDC|9.2|1,309||||| ||24 VDC|4.6|5,236||||| Note. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. * Operating voltage is less than 72% when the relay is sideways and the marking is right way. ## ● **Contacts** ||Resistive load|Inductive load (cosφ= 0.4, L/R = 7 ms)| |---|---|---| |Contact Type|Cross bar twin|| |Contact material|Ag-Alloy and Au plating *|| |Rated load|5 A at 250 VAC<br>5 A at 30 VDC|2 A at 250 VAC<br>2 A at 30 VDC| |Rated carry current|5 A|| |Max. switching voltage|277 VAC, 125 VDC|| |Max. switching current|5 A|| * Au plating is applied to stationary contact. **1** G6DN **PCB Power Relay** G 6 D N ## ■ **Characteristics** |||Standard|High durability|General purpose| |---|---|---|---|---| |Contact resistance||100 mΩmax.||| |Operate time||10 ms max.||| |Release time||5 ms max.||| |Insulation resistance||1,000 MΩmin. (at 500 VDC)||| |Dielectric strength|Between coil and<br>contacts|3,000 VAC, 50/60 Hz for 1 min||| ||Between contacts of<br>the same polarity|750 VAC, 50/60 Hz for 1 min||| |Surge withstand<br>voltage|Between coil and<br>contacts|6 kV (1.2✕50μs)||| |Vibration resistance|Destruction|10 to 55 to 10 Hz, 2.5 mm single amplitude (5.0 mm double amplitude)||| ||Malfunction|10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)||| |Shock resistance|Destruction|1,000 m/s2||| ||Malfunction|100 m/s2||| |Durability|Mechanical|20,000,000 operations min. (at 18,000 operations/hr)||| ||Electrical|100,000 operations min.<br>(3 A at 250 VAC,<br>3 A at 30 VDC Resistive load)<br>80,000 operations min.<br>(5 A at 250 VAC,<br>5 A at 30 VDC Resistive load)<br>100,000 operations min.<br>(2 A at 250 VAC,<br>2 A at 30 VDC Inductive load)|100,000 operations min.<br>(5 A at 250 VAC, Resistive load)<br>100,000 operations min.<br>(5 A at 30 VDC, Resistive load)<br>200,000 operations min.<br>(2 A at 250 VAC, Inductive load)<br>200,000 operations min.<br>(2 A at 30 VDC, Inductive load)|50,000 operations min.<br>(5 A at 250 VAC, Resistive load)<br>50,000 operations min.<br>(5 A at 30 VDC, Resistive load)<br>100,000 operations min.<br>(2 A at 250 VAC, Inductive load)<br>100,000 operations min.<br>(2 A at 30 VDC, Inductive load)| |Failure rate (P level) (reference value) *||0.1 mA at 0.1 VDC||| |Ambient temperature|Operating|-40°C to +90°C (with no icing or condensation)||| |Humidity||5% RH to 85% RH||| |Weight||Approx. 3 g||| Note 1. Values in the above table are initial values. Note 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. Note 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC. * This value was measured at a switching frequency of 120 operations/min. **2** G6DN **PCB Power Relay** G 6 D N ## ■ **Engineering Data** - **Maximum Switching Capacity** ## ● **Durability** - **Ambient Temperature vs. Maximum Coil Voltage** **==> picture [511 x 420] intentionally omitted <==** **----- Start of picture text -----**<br> ● G6DN-1A, G6DN-1A-L ● G6DN-1A ● G6DN-1A, G6DN-1A-L<br>50 500 200<br>30 a 300 -—}—_|__|<br>180<br>ee nemnnees Mott ttt td C LL ELL EE<br>100<br>10 | || ees 160<br>5 AC resistive load 50<br>2.53 SHS tem) = 2530 See 250 VAC/30 VDC Resistive load SSS 140126 Le<br>PEE EHEC Ce 120 ptt ee<br>1 DC resistive load 10<br>0.40.5 eySS Nlee 5 Sees 250 VAC/30 VDCInductive load ——<—<—<—$<_———— 100 6 TT<br>0.3 3<br>80<br>SH ee<br>0.1 1 OE 3 5 10 CIT 30 100 125 277 500 1,000 0 1 Perererer))~=6o 2 3 4 5 6 7 8 9 10 600 LEE 23 30 40 ETE 50 60 70 80 90 100<br>Switching voltage (V) Switching current (A) Ambient temperature (°C)<br>Note. The maximum coil voltage refers to the<br>maximum voltage in a varying range of<br>operating power voltage, not a continuous<br>voltage.<br>● Ambient Temperature vs. Must ● Shock Malfunction<br>Operate and Must Release Voltages<br>G6DN-1A, G6DN-1A-L<br>90 Y1,000 Energized<br>80 TL LLLLLIL 800 ! Sample: G6DN-1A<br>70 PT max. X1,000 600 De-energized 1,000Z Number of Relays: 5 pcsTest conditions: Impose a shock in the ±X,<br>X 400 ±Y, and ±Z directions three times each with<br>60 Ss min . 200 the Relay energized to check the shock<br>50 values that cause the Relay to malfunction.<br>ae | Standard:100 m/s [2]<br>40 aT<br>30 Z' X'<br>PPT ETT) 1,000 hock 1,000<br>max.<br>20 a X —<br>10 eS — min. 1,000 ~ Y' Shock directionUnit: m/s [2]<br>0 Pree Y X _. X'<br>−60 −40 −20 0 20 40 60 80 100 Z<br>Ambient temperature (°C) Z'<br>Y' ‘C8<br>Coil terminals<br>4 operations)<br>Switching current (A) Durability (x10 Maximum coil voltage (%)<br>Must operate and must release voltage (ratio of rated voltage) (%)<br>**----- End of picture text -----**<br> ## ● **G6DN-1A, G6DN-1A-L** ● **Ambient Temperature vs. Must Operate and Must Release Voltages G6DN-1A, G6DN-1A-L** ## ■ **Dimensions** ## **G6DN-1A(-L)** **==> picture [403 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 5.08 max. PCB Mounting Holes Terminal Arrangement/<br>20 max. (5.05)* (Bottom View) Internal Connections<br>(19.97)* (Bottom View)<br>7.62± [0.1]<br>12.5 max. 7.62± [0.1] Four, 1.1-dia. holes<br>(12.45)* 2.54± [0.1]<br>1 2 5 8<br>3.3<br>Two, 0.4-dia. t 0.2 t 0.26 2-0.8 1.28 (1.32) (1.28) (No coil polarity)<br>7.62 7.62<br>2.54 1.32<br>**----- End of picture text -----**<br> * Average value ## **G6DN-1A-SL** **==> picture [391 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> 5.08 max. PCB Mounting Holes Terminal Arrangement/<br>20 max. (Bottom View) Internal Connections<br>7.62± [0.1] (Bottom View)<br>12.5 max. 7.62± [0.1] Four, 1.1-dia. holes<br>2.54± [0.1]<br>1 2 5 8<br>3.3<br>2-t0.3<br>2-0.5 t 0.2 t 0.26 2-0.8 1.28 (1.32) (1.28) (No coil polarity)<br>7.62 7.62<br>2.54 1.32<br>**----- End of picture text -----**<br> **3** **PCB Power Relay** G 6 D N ## G6DN ## ■ **Approved Standards** - The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this datasheet. **UL/C-UL-approved models** (File No. E41515) |Model|Contact form|Coil ratings|Contact ratings|Operations| |---|---|---|---|---| |G6DN-1A(-SL)|SPST-NO|4.5 to 24 VDC|5 A at 277 VAC (Resistive) 95°C|6,000| ||||5 A at 30 VDC (Resistive) 90°C|6,000| ||||3A, 250V ac, Resistive 85°C|100,000| ||||1/10 hp 125 VAC 95°C|1,000| ||||1/10 hp 277 VAC 95°C|1,000| ||||D300 120 VAC/240 VAC 95°C|6,000| ||||C300 120 VAC/240 VAC 95°C|6,000| ||||R300 125 VDC/250 VDC 95°C|6,000| |G6DN-1A-L|SPST-NO|5 to 24 VDC|5 A 250 VAC (Resistive) 95°C|100,000| ||||2 A 250 VAC (General Use) 95°C|100,000| ||||2 A 30 VDC (General Use) 95°C|100,000| ||||1/10 hp 120 VAC 40°C|6,000| ||||C300 120 VAC/240 VAC 95°C|6,000| ||||D150 120 VAC 95°C|6,000| ||||R150 125 VDC 95°C|6,000| Note. CSA certification CSA 22.2 No.14 can be recognized by C-UL. ## **VDE (EN61810-1)** (Certificate No. 40042696) |Model|Contact form|Coil ratings|Coil ratings|Contact ratings|Operations| |---|---|---|---|---|---| |G6DN-1A-SL|SPST-NO|5, 12, 24 VDC||5 A at 250 VAC (cosφ= 1.0) 90°C|10,000| |||||5 A at 30 VDC (L/R = 0 ms) 90°C|10,000| ||||||| |Clearance distance|||3.5 m|m min.|| |Creepage distance|||3.6 m|m min.|| |Type of insulation coil-contact circuit<br>open contact circuit|||Basic|(PD.2)|| ||||Micro|disconnection|| |Rated Insulation voltage|||300 V||| |Pollution degree|||2||| |Rated voltage system|||250 V||| |Over voltage category|||II||| |Category of protection according to IEC 61810-1|||RT III|(Sealed)|| |Insulation material group|||I||| |Tracking resistance according to IEC 60112|||CTI 600 V min.||| |Flammability class according to UL94|||V-0||| |Coil insulation system according to UL|||Class B||| ## ■ **Precautions** ● **Please refer to “PCB Relays Common Precautions” for correct use.** **4** G6DN **PCB Power Relay** G 6 D N Please check each region's Terms & Conditions by region website. ## **OMRON Corporation Electronic and Mechanical Components Company** ## **Regional Contact** **Americas Europe** https://www.components.omron.com/ http://components.omron.eu/ **Asia-Pacific China** https://ecb.omron.com.sg/ https://www.ecb.omron.com.cn/ **Korea Japan** https://www.omron-ecb.co.kr/ https://www.omron.co.jp/ecb/ © OMRON Corporation 2018-2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. K276-E1-08** 0218(1115) **5**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →