G6D-4-SB
SHORT BAR, TERMINAL RELAY
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Other Relay Accessories
- For Use With: G6D-F4B/G3DZ-F4B Series Terminal Relays
- Accessory Type: Short Bar
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 1.24 € |
| Current stock | 10+ |
| Lead time | 7 days |
CSM_G6D-F4B_G3DZ-F4B_DS_E_5_5 ## **Terminal Relay G6D-F4B/G3DZ-F4B** ## **Easy-to-use, Space-saving Terminal Relay with Four-point Output** - Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) - Each terminal circuit (with coil or contact) is independent from one another. - Short Bar ensures easy connection of common and adjacent terminals. - Provided with a terminal cover that prevents electric-shock accidents. - Relay and MOS FET relay models are available. - LED operation indicator. - Built-in diode absorbs coil surge. - Mounts either on DIN track or screws. - Tool for easy mounting or removal of Relays provided. - UL, CSA, and VDE certification for standard models (VDE: G6D-F4B only). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. ## **Model Number Structure** ## ■ **Model Number Legend** ## **G6D/G3DZ-** @@ **1 2** **1. Terminal Form** - F: Flat type **2. Number of Relays Mounted** 4B: 4 ## **Orderin Information g** ~~SSS~~ **When your order, specify the rated voltage.** ## ■ **List of Models** |**Output**|**Contact configuration**|**Model**|**Rated voltage**| |---|---|---|---| |Relay output|SPST-NO×4|G6D-F4B|12 VDC| ||||24 VDC| |Power MOS FET relay out-<br>put||G3DZ-F4B|12 VDC| ||||24 VDC| **Note:** When ordering add the rated coil voltage to the model number. Example: G6D-F4B 24 VDC Rated coil voltage **1** **G6D-F4B/G3DZ-F4B** ## **S ecifications p** ## ■ **Ratings** ## **Coil Ratings (per G6D Relay)** |**Rated voltage**|**Rated current**|**Coil resistance**|**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Max. voltage**|**Power**<br>**consumption**| |---|---|---|---|---|---|---| |12 VDC|18.7 mA|720Ω|70% max.<br>(see note 1)|10% min.|130%|Approx. 200 mW| |24 VDC|10.5 mA|2,880Ω||||| - **Note: 1.** The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down. **2.** Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%. **3.** Operating characteristics were measured at a coil temperature of 23°C. **4.** The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. **5.** The rated current includes the terminal’s LED current. ## **Contact Ratings (per G6D Relay)** |**Item**|**Resistive load (cos**φ**= 1)**| |---|---| |**Rated load**|3 A at 250 VAC, 3 A at 30 VDC| |**Rated carry current**|5 A| |**Max. switching voltage**|250 VAC, 30 VDC| |**Max. switching current**|5 A| |**Max. permissible capacity (reference value)**|1,250 VA, 150 W| |**Error rate (reference value) (see note)**|5 VDC, 10 mA| **Note:** This value is for a switching frequency of 120 times per minute. ## ■ **Power MOS FET Relay Specifications** ## **Input (per G3DZ Power MOS FET Relay)** |**Rated voltage**|**Operating voltage**|**Must operate**<br>**voltage level**|**Must release**<br>**voltage level**|**Input impedance**|**Rated current**| |---|---|---|---|---|---| |12 VDC|9.6 to 14.4 VDC|9.6 VDC max.|1 VDC min.|2 kΩ±20%|8.0 mA±20%| |24 VDC|19.2 to 28.8 VDC|19.2 VDC max.||4 kΩ±20%|8.2 mA±20%| **Note:** The rated current includes the terminal’s LED current. ## **Output (per G3DZ Power MOS FET Relay)** |**Load voltage**|**Load current**|**Inrush current**| |---|---|---| |3 to 264 VAC<br>3 to 125 VDC|100μto 0.3 A|6 A (10 ms)| **Note:** There is no output polarity for the G3DZ. **2** **G6D-F4B/G3DZ-F4B** ## ■ **Characteristics** |■**Characteristics**|| |---|---| |**Item**|**G6D-F4B**| ||**Relay output**| |**Contact resistance (see note 2)**|100 mΩmax.| |**Must operate time (see note 3)**|10 ms max.| |**Release time (see note 3)**|10 ms max.| |**Insulation resistance**|1,000 MΩmin. (at 500 VDC)| |**Dielectric strength**|2,000 VAC, 50/60 Hz for 1 min between coil and contacts.| ||1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity| ||750 VAC, 50/60 Hz for 1 min between contacts of same polarity| |**Impulse withstand voltage (between**<br>**coil and contacts)**|4,000 V (1.2×50μs)| |**Vibration resistance**|Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)<br>Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude(1.5-mm double amplitude)| |**Shock resistance**|Destruction: 500 m/s2<br>Malfunction: 100 m/s2| |**Endurance**|Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)<br>Electrical:<br>100,000 operations min. (3 A at 250 VAC, resistive load)<br>100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr)| |**Ambient temperature**|Operating: –25°C to 55°C (with no icing)| |**Ambient humidity**|Operating: 45% to 85%| |**Weight**|Approx. 65g| **Note: 1.** The above values are initial values. **2.** Measurement condition: 1 A at 5 VDC **3.** Ambient temperature condition: 23°C |**Item**|**G3DZ-F4B**| |---|---| ||**Power MOS FET relay output**| |**Must operate time**|10 ms max.| |**Release time**|15 ms max.| |**Output ON-resistance**|2.4Ωmax.| |**Leakage current at OFF state**|10μA max. (at 125 VDC)| |**Insulation resistance**|100 MΩmin. (at 500 VDC)| |**Dielectric strength**|2,000 VAC, 50/60 Hz for 1 min between input and output terminals| ||1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity| |**Vibration resistance**|Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude(1.5-mm double amplitude)| |**Shock resistance**|Destruction: 500 m/s2| |**Ambient temperature**|Operating: –25°C to 55°C (with no icing)| |**Ambient humidity**|Operating: 45% to 85%| |**Weight**|Approx. 65g| **3** **G6D-F4B/G3DZ-F4B** ## **En ineerin Data g g** ## **Maximum Switching Power** ## **Endurance** ## **G6D-F4B** **==> picture [165 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> 500<br>300 Li | ty | ty yt<br>100 PCP PLLLLLL<br>250 VAC/30 VDC resistive load<br>50 NSS EAN op<br>30 [ [NONUZT]<br>rN NEE | Et td<br>10 LINN| Et tt<br>——_——_——————————a<br>5 250 VAC/30 VDC inductive load =<br>3 Yr (cos | φ = 0.4, L/R = 7 ms) | | | ft ft fe4<br>0 1 PPP 2 3 4 5 6 PPT 7 8 9 10<br>Switching current (A)<br> operations)<br>4<br>Endurance (x10<br>**----- End of picture text -----**<br> **==> picture [196 x 334] intentionally omitted <==** **----- Start of picture text -----**<br> COI Cn<br>TE<br>PEE<br>Sooo<br>3, — DC resistive load AC resistive load imal<br>a ee Pee<br>eT<br>oy a a a ||<br>05SSE<br>0.3)PPa TT<br>et 0 LUTTIME3 5 10 TUTINE30 50 100 TUTTI250 500<br>Switching voltage (V)<br> Load Current vs.<br>Ambient Temperature<br>1T<br>08 || . rr } re ee<br>06|— | = T7744<br>| |<br>; Z<br>’<br>—2 —20 o 20 40 55.60 ao (100<br>Ambient temperature (°C)<br>4<br>Switching current (A)<br>Endurance (x10<br>Load current (A)<br>Inrush current (A. Peak)<br>**----- End of picture text -----**<br> ## |a **Load Current vs. Inrush Current Resistivity: Non-repetitive Ambient Temperature** Keep the inrush current to half the rated value if it occurs repetitively. **G3DZ-F4B** **==> picture [76 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Energizing time (ms)<br>**----- End of picture text -----**<br> **4** **G6D-F4B/G3DZ-F4B** ## **Dimensions** **Note:** All units are in millimeters unless otherwise indicated. ## **G6D-F4B G3DZ-F4B** **==> picture [379 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Dimensions<br>16, M3 Phillips<br>: head screws Two, 4 dia. holes or M3.5 screw holes<br>8.7<br>4 3 2 1 Terminal Arrangement/<br>Internal Connections<br>8 7 6 5 (Top View)<br>IN 1 2 3 4 Input side 4 8 3 7 2 6 1 5<br>68 max. R Y 1 R Y 2 R Y 3 R Y 4 76±0.3<br>OUT 1 2 3 4<br>12 11 10 9 Output side<br>12 11 10 9<br>16 15 14 13 c e<br>E 16 15 14 13<br>8.7<br>31 max. 35 max. 23±0.3 Note1 : Make sure that the polarity of<br>Tool for removing relays. the input terminal is correct.<br>Note2 : There is no output polarity for<br>the G6D-F4B and G3DZ-F4B.<br>**----- End of picture text -----**<br> ## ■ **Accessories (Order Separately)** ## **G6D-4-SB Short Bar** |**Applicable model**|**Model**| |---|---| |**G6D-F4B**|G6D-4-SB| |**G3DZ-F4B**|| ## **Relay Mounting Products** ~~ee~~ |**Name**<br>~~ee~~|**Model**<br>~~ee~~| |---|---| |Mounting track<br>PFP-100N<br>PFP-50N<br>PFP-100N2|PFP-100N| ||PFP-50N| ||PFP-100N2| |End plate<br>PFP-M|PFP-M| |PFP-S|PFP-S| ## **Short Bar** ~~_~~ ## **Short Bar** |**Applicable Terminal Relay**<br>~~_~~|**Model**| |---|---| |G6D-F4B<br>G6D-4-SB<br>G3DZ-F4B|G6D-4-SB| ## **Replacement Relays** |**Applicable Terminal**<br>**Relay**|**Model**|**Rated voltage**| |---|---|---| |G6D-F4B|G6D-1A-ASI|12 VDC<br>24 VDC| |G3DZ-F4B|G3DZ-2R6PL|12 VDC<br>24 VDC| **Note:** Error rate (P level) for the G6D-1A-ASI is 5 V at 10 mA and that for the G6D-1A-AP is 5 V at 1 mA. **5** **G6D-F4B/G3DZ-F4B** ## **Safet Precautions y** Refer to _Safety Precautions for All Relays_ . ## **Wiring** Be sure to turn OFF the power when wiring the Unit and do not touch the charged terminals of the Unit. Otherwise, an electric shock may result. Do not apply overvoltage to the input terminals. Otherwise, the Unit may malfunction or burn. ## **Relay Models** Do not connect the Unit to loads exceeding the rated switching power (switching voltage or current). Otherwise, faulty insulation, contact weld, or faulty contact of Relays, or damage to Relays may result, or the Relays may malfunction or burn. The life of Relays varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Unit in locations with inflammable gas. Otherwise, a fire or explosion due to the heat of the Relays or sparks from the Relays may result when they are switched. ## **SSR Output (Power MOS FET Relay Model)** Do not connect the Unit to loads consuming a total current exceeding the rated output current of the Unit. Otherwise, the output element of the Unit may be damaged and a short or open-circuit malfunction may result. If the Unit is connected to a DC inductive load, connect a diode to the Unit to protect the Unit from counter-electromotive voltage, otherwise the counter-electromotive voltage may damage the output element and a short or open-circuit malfunction may result. ## ■ **Correct Use** ## **Mounting** When mounting two or more Units, reduce the current and ON duty and provide an appropriate distance between the Units so that the ambient temperature will not exceed 55°C. ## **Relay Replacement** Use the Relay Removal Tool provided with the Unit to dismount a Relay. Be sure to turn OFF the power to the Unit before replacing a Relay. When mounting a Relay, insert the Relay vertically so that the relay terminals will come in contact with the socket contact pins properly. Do not mount Relays that are different to one another in voltage. ## **Wiring** Pay utmost attention not to make mistakes with the polarity of the input terminals. ## **Coil Voltage** Make sure not to impose voltage exceeding the permissible voltage on the coil continuously. Do not connect any inductive load in parallel to the coil input as shown in the following example or power supply with a surge voltage. Otherwise, the surge absorption diode will be damaged. ## **Do Not Use the Following Circuit** Coil surge Inductive load G6D coil absorption diode fn ## **Handling** Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction. Make sure that all the Relays are properly mounted before use. ## **Screw Tightening Torque** Tighten each terminal screw to a torque described below. M3 terminal screw: 0.4 to 0.56 N·m. M3.5 terminal screw: 0.78 to 1.18 N·m. Tighten each mounting screw to a torque of 0.59 to 0.98 N·m. ## **Installation Environment** Do not install the Unit in the following locations. Otherwise, damage to the Unit may result or the Unit may malfunction. Locations with direct sunlight. Locations with an ambient temperature range not within –25°C to 55°C. Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 45% to 85%. Locations with corrosive or inflammable gas. Locations with excessive dust, salinity, or metal powder. Locations with vibration or shock affecting the Unit. Locations with water, oil, or chemical sprayed on the Unit. ## **Disassembly, Repair, and Modification** Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction. ## **Mounted Relays** Relays and SSRs cannot be mounted together. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. ~~Pe~~ To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. **6** ~~a~~ ## Terms and Conditions Agreement ## Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. **In the interest of product improvement, specifications are subject to change without notice.** ## **OMRON Corporation** ## **Industrial Automation Company** 2017.3 **http://www.ia.omron.com/** (c)Copyright OMRON Corporation 2017 All Right Reserved.
Updated at February 9, 2023
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →