G6CK-2114P-US-DC12
Power Relay, SPST-NO, SPST-NC, 12 VDC, 8 A, G6C Series, Through Hole, Latching Dual Coil
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Latching Dual Coil
- Coil Voltage: 12VDC
- Product Range: G6C Series
- Relay Mounting: Through Hole
- Coil Resistance: 514ohm
- Contact Current: 8A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPST-NO, SPST-NC
| Delivery and price | |
|---|---|
| Units per pack | 36 |
| Price | 8.68 € |
| Current stock | 100+ |
| Lead time | 30 days |
G6C PCB Power Relay G 6 C ## **Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A** - SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and output that satisfy the needs for space-saving. - Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H). - Low power consumption: 200 mW. - Ultrasonically cleanable models is available. - Exclusive P6C model for sockets is now available. ## **RoHS Compliant** ## ■ **Model Number Legend** G6C-@ - @@ @@@-@-@-@-@ 1 2 3 4 5 6 7 8 9 ## **1. Relay Function** None: Single-side stable - U : Single-winding latching - K : Double-winding latching ## **2. Contact Form** - 11: SPST-NO (1a) - 21: SPST-NO (1a) + SPST-NC (1b) **3. Contact Type** - 1: Single ## **4. Enclosure rating** - 4: Fully sealed - 7: Flux protection **5. Terminal Shape** - P: PCB terminals Socket mounting Terminals ## **6. Contact Material** None: Standard (Ag-alloy (Cd free)) FD : AgSnIn Contacts (Suitable for DC inductive load with high inrush current) ## **7. Approved Standards** US: UL/CSA ## **8. Washability** None: Standard model - (not compatible with ultrasonically cleanable models) - U : For ultrasonically cleanable ## **9. Mounting** None: Mounted directly to PCB P6C : Mounted to Socket ## ■ **Application Examples** Ideal for output applications of control equipments **1** G6C **PCB Power Relay** ## ■ **Ordering Information** ## ● **Standard Models (UL, CSA certified)** |G<br>6<br>C||Relay<br>Function|Single-side stable|Single-side stable|Single-winding latching|Single-winding latching|Double-winding latching<br> <br>Model<br>Rated coil<br>voltage|Double-winding latching<br> <br>Model<br>Rated coil<br>voltage|Double-winding latching<br> <br>Model<br>Rated coil<br>voltage|Minimun<br>packing unit| |---|---|---|---|---|---|---|---|---|---|---| ||Enclosure<br>rating|Contact<br>form|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|Model|||| ||Flux protection|<br>SPST-NO<br>(1a)|**G6C-1117P-US**|3 VDC|**G6CU-1117P-US**|3 VDC|**G6CK-1117P-US**|3 VDC<br>5 VDC<br>6 VDC<br>12 VDC<br>24 VDC<br>3 VDC<br>5 VDC<br>6 VDC<br>12 VDC<br>24 VDC||100 pcs/<br>tray| |||||5 VDC||5 VDC||||| |||||6 VDC||−||||| |||||12 VDC||12 VDC||||| |||||24 VDC||24 VDC||||| |||<br>SPST-NO<br>(1a) +<br>SPST-NC<br>(1b)|**G6C-2117P-US**|3 VDC|**G6CU-2117P-US**|3 VDC|**G6CK-2117P-US**|||| |||||5 VDC||5 VDC||||| |||||6 VDC||6 VDC||||| |||||12 VDC||12 VDC||||| |||||24 VDC||24 VDC||||| ||Fully sealed|SPST-NO<br>(1a)|**G6C-1114P-US**|3 VDC|**G6CU-1114P-US**|3 VDC|**G6CK-1114P-US**|3 VDC<br>5 VDC<br>6 VDC<br>12 VDC<br>24 VDC<br>3 VDC<br>5 VDC<br>6 VDC<br>12 VDC<br>24 VDC||100 pcs/<br>tray| |||||5 VDC||5 VDC||||| |||||6 VDC||6 VDC||||| |||||12 VDC||12 VDC||||| |||||24 VDC||24 VDC||||| |||SPST-NO<br>(1a) +<br>SPST-NC<br>(1b)|**G6C-2114P-US**|3 VDC|**G6CU-2114P-US**|3 VDC|**G6CK-2114P-US**|||| |||||5 VDC||5 VDC||||| |||||6 VDC||6 VDC||||| |||||12 VDC||12 VDC||||| |||||24 VDC||24 VDC||||| ||||||||||CONTACT:<br>TV-5<br>8A 250VAC<br>8A 30VDC<br>COIL:24VDC<br>24VDC<br>MADE IN<br>JAPAN<br>G6C-2114P<br>-US|| Note1.When ordering, add the rated coil voltage to the model number. Example: G6C-1117P-US DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models). **==> picture [130 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> G6C-1117P G6C-2114P<br>-US CONTACT: -US CONTACT:<br>TV-5 TV-5<br>24VDC 10A 250VAC 24VDC 8A 250VAC<br>MADE IN 10A 30VDC MADE IN 8A 30VDC<br>JAPAN COIL:24VDC JAPAN COIL:24VDC<br>**----- End of picture text -----**<br> ## ● **Ultrasonically Cleanable Models (UL, CSA certified)** ||Relay<br>Function|Single-side stable|Single-side stable|Single-winding latching|Single-winding latching|Double-winding latching<br> <br>Model<br>Rated coil<br>voltage|Double-winding latching<br> <br>Model<br>Rated coil<br>voltage|Minimun<br>packing unit| |---|---|---|---|---|---|---|---|---| |Enclosure<br>rating|Contact<br>form|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|Model||| |Fully sealed|SPST-NO<br>(1a)|**G6C-1114P-US-U**|3 VDC|**G6CU-1114P-US**|−|**G6CK-1114P-US**|−<br>5 VDC<br>−<br>12 VDC<br>24 VDC<br>−<br>5 VDC<br>−<br>12 VDC<br>−|100 pcs/<br>tray| ||||5 VDC||5 VDC|||| ||||6 VDC||−|||| ||||12 VDC||12 VDC|||| ||||24 VDC||−|||| ||SPST-NO<br>(1a) +<br>SPST-NC<br>(1b)|**G6C-2114P-US-U**|−|**G6CU-2114P-US**|−|**G6CK-2114P-US**||| ||||5 VDC||−|||| ||||−||−|||| ||||12 VDC||−|||| ||||24 VDC||−|||| Note1.When ordering, add the rated coil voltage to the model number. Example: G6C-1114P-US-U DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models). **==> picture [130 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> G6C-1117P G6C-2114P<br>-US CONTACT: -US CONTACT:<br>TV-5 TV-5<br>24VDC 10A 250VAC 24VDC 8A 250VAC<br>MADE IN 10A 30VDC MADE IN 8A 30VDC<br>JAPAN COIL:24VDC JAPAN COIL:24VDC<br>**----- End of picture text -----**<br> ## ● **Connecting Sockets (Sold Separately)** |Applicable relays|Model|Minimun packing unit| |---|---|---| |G6C-2114P-US-P6C<br>G6C-2117P-US-P6C<br>G6C-1114P-US-P6C<br>G6C-1117P-US-P6C<br>G6CU-2114P-US-P6C<br>G6CU-2117P-US-P6C<br>G6CU-1114P-US-P6C<br>G6CU-1117P-US-P6C|**P6C-06P**|20 pcs/tube| |G6CK-2114P-US-P6C<br>G6CK-2117P-US-P6C<br>G6CK-1114P-US-P6C<br>G6CK-1117P-US-P6C|**P6C-08P**|| |Removal Tool|**P6B-Y1**|1| |Hold-down Clips|**P6B-C2**|| Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket. 2. When using by combining sockets, the rated current will be 5A due to its rated switching current. **2** G6C **PCB Power Relay** G 6 C ## ■ **Ratings** ## **Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)** |Item|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must operate<br>voltage<br>(V)|Must release<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power<br>consumption<br>(mW)| |---|---|---|---|---|---|---| |Rated voltage|||% of rated voltage|||| |3 VDC|67|45|70% max.|10% min.|160%<br>(at 23°C)|Approx. 200| |5 VDC|40|125||||| |6 VDC|33.3|180||||| |12 VDC|16.7|720||||| |24 VDC|8.3|2,880||||| ## **Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)** |Item|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must set<br>voltage<br>(V)|Must reset<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---| |Rated voltage||||||Set coil<br>(mW)|Reset coil<br>(mW)| ||||% of rated voltage||||| |3 VDC|67|45|70% max.|70% max.|160%<br>(at 23°C)|200|200| |5 VDC|40|125|||||| |6 VDC|33.3|180|||||| |12 VDC|16.7|720|||||| |24 VDC|8.3|2,880|||||| ## **Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)** |Item|Rated current (mA)|Rated current (mA)|Coil resistance (Ω)|Coil resistance (Ω)|Must set<br>voltage<br>(V)|Must reset<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---|---|---| |Rated voltage|Set coil|Reset coil|Set coil|Reset coil||||Set coil<br>(mW)|Reset coil<br>(mW)| ||||||% of rated voltage||||| |3 VDC|93.5|93.5|32.1|32.1|70% max.|70% max.|130%<br>(at 23°C)|280|280| |5 VDC|56.0|56.0|89.3|89.3|||||| |6 VDC|46.7|46.7|129|129|||||| |12 VDC|23.3|23.3|514|514|||||| |24 VDC|11.7|11.7|2,056|2,056|||||| - Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.The operating characteristics are measured at a coil temperature of 23°C. - 3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ## **Contact** |Contact Form<br>Rated load<br>Item|SPST-NO (1a)|SPST-NO (1a)|SPST-NO (1a) + SPST-NC (1b)|SPST-NO (1a) + SPST-NC (1b)| |---|---|---|---|---| ||Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)|Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)| ||10 A (8 A) at 250 VAC<br>10 A (10 A) at 30 VDC|5 A (5 A) at 250 VAC<br>5 A (5 A) at 30 VDC|8 A (8 A) at 250 VAC<br>8 A (8 A) at 30 VDC|3.5 A (3.5 A) at 250 VAC<br>3.5 A (3.5 A) at 30 VDC| |Contact type|Single|||| |Contact material|Ag-Alloy (Cd free)|||| |Rated carry current|10 A (10 A)||8 A (8 A)|| |Max. switching voltage|380 VAC, 125 VDC|||| |Max. switching current|10 A (10 A)||8 A (8 A)|| Note. The values shown in parentheses ( ) are for -FD models only. **3** G6C **PCB Power Relay** G 6 ## ■ **Characteristics (Including models for ultrasonically cleanable)** C |■**Characteristics(Incl**|■**Characteristics(Incl**|**uding models fo**|**r ultrasonically cle**|**anable)**| |---|---|---|---|---| |Item<br>Classification||Single-side Stable|Single-windingLatching|Double-windingLatching| |Contact resistance *1||30 mΩmax.||| |Operate(set)time||10 ms max.||| |Release(reset)time||10 ms max.||| |Min. setpulse width||−|20 ms(at 23°C)|| |Min. resetpulse width||−|20 ms(at 23°C)|| |Insulation<br>resistance *2|Between coil and<br>contacts|1,000 MΩmin.||| ||Between contacts of the<br>samepolarity|1,000 MΩmin.||| ||Between contacts of<br>differentpolarity|1,000 MΩmin. (SPST-NO, SPST-NC)||| ||Between set and reset<br>coils|−|−|1,000 MΩmin.| |Dielectric<br>strength|Between coil and<br>contacts|2,000 VAC 50/60Hz for 1min||| ||Between contacts of the<br>samepolarity|1,000 VAC 50/60Hz for 1min||| ||Between contacts of<br>differentpolarity|2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC)||| ||Between set and reset<br>coils|−|−|250 VAC 50/60Hz for<br>1min| |Vibration<br>resistance|Destruction|10 to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)||| ||Malfunction|10 to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)||| |Shock<br>resistance|Destruction|1,000 m/s2||| ||Malfunction|100 m/s2||| |Durability|Mechanical|50,000,000 operations min.(at 18,000 operations/hr)||| ||Electrical|100,000 operation min.(at 1,800 operations/hr under rated load)||| |Failure rate(P level) (reference value)*3||10 mA at 5 VDC||| |Ambient operatingtemperature||-25°C to 70°C(with no icingor condensation)||| |Ambient operatinghumidity||5% to 85%||| |Weight||Approx. 5.6g||| Note. The given values are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Testing conditions: measured with a 500 VDC megohmmeter (at 250 VDC between set/reset coil). *3. This value was measured at a switching frequency of 120 operations/min. ## ■ **Engineering Data** ## ● **Maximum Switching Capacity G6C-1114P-US G6C-1117P-US** **==> picture [512 x 358] intentionally omitted <==** **----- Start of picture text -----**<br> G6C-1114P-US G6C-1114P-FD-US G6C-2114P-US<br>G6C-1117P-US G6C-1117P-FD-US G6C-2117P-US<br>50 50 50<br>30 30 30<br>AC resistive load AC resistive load AC resistive load<br>10 10 10<br>7 8 8<br>5 5 5<br>3 DC resistive load AC inductive load 32 DC resistive load AC inductive load 32 DC resistive load AC inductive<br>1 DC inductive load (L/R = 7 ms) (cosφ = 0.4) 1 DC inductive load (cosφ = 0.4) 1 DC inductive load (L/R = 7 ms) load(cosφ = 0.4)<br>0.7 0.7 (L/R = 7 ms) 0.7<br>0.5 0.5 0.5<br>0.3 0.3 0.3<br>0.2 0.2 0.2<br>0.1 0.1 0.1<br>1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000<br>Switching voltage (V) Switching voltage (V) Switching voltage (V)<br>G6C-2114P-FD-US<br>G6C-2117P-FD-US<br>50<br>30<br>AC resistive load<br>10<br>8<br>5<br>3<br>2 AC inductive<br>load<br>1 DC resistive load (cosφ = 0.4)<br>0.7 DC inductive load<br>0.5 (L/R = 7 ms)<br>0.3<br>0.2<br>0.1<br>1 3 5 7 10 30 50 100 250 380 1,000<br>Switching voltage (V)<br>Switching current (A) Switching current (A) Switching current (A)<br>Switching current (A)<br>**----- End of picture text -----**<br> ## **G6C-2114P-FD-US** ## **G6C-2117P-FD-US** **4** **PCB Power Relay** G 6 C ## G6C ## ● **Durability** **G6C-1114P-US, G6C-2114P-US G6C-1117P-US, G6C-2117P-US** ## **G6C-1114P-FD-US, G6C-2114P-FD-US G6C-1117P-FD-US, G6C-2117P-FD-US** **==> picture [329 x 532] intentionally omitted <==** **----- Start of picture text -----**<br> 500 500<br>G6C-2114P-FD-US<br>300 300 G6C-2117P-FD-US<br>250 VAC resistive G6C-1114P-FD-US<br>30 VDC resistive G6C-1117P-FD-US<br>100 G6C-2114P-US G6C-2117P-US 100 250 VAC resistive<br>250 VAC resistive G6C-1114P-US G6C-1114P<br>50 30 VDC resistive G6C-1117P-US 50 -FD-US<br>30 250 VAC resistive30 VDC resistive 30 G6C-FD-US-1117P<br>30 VDC resistive<br>10 10<br>531 G6CG6C-2117P-US250 VAC inductive(cos30 VDC inductive (L/R = 7 ms) φ-2114P = 0.4)-US G6C-1114P-US G6C-1117P-US250 VAC inductive(cos 30 VDC inductive (L/R = 7 ms)φ = 0.4) 531 G6C-2114P-FD-US G6C-2117P-FD-US250 VAC inductive (cos30 VDC inductive (L/R = 7 ms)φ = 0.4) G6CG6C-1117P-FD-US250 VAC inductive (30 VDC inductive (L/R = 7 ms)cosφ -1114P = 0.4) -FD-US<br>0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11<br>Switching current (A) Switching current (A)<br>● Ambient Temperature vs. ● Ambient Temperature vs Must<br>Maximum Coil Voltage Operate and Must Release voltages<br>200 100<br>Sample: Must operate voltage<br>G6C-114P-US Must release voltage<br>180 Number of Relays: max.<br>80 5 pcs X<br>160 min.<br>60<br>140<br>130<br>120<br>40<br>max.<br>100 X<br>20 min.<br>80<br>60 0<br>10 20 23 30 40 50 60 70 80 90 -40 -20 0 20 40 60 80<br>Ambient temperature (°C) Ambient temperature (°C)<br>Note. The maximum coil voltage refers to the<br>maximum value in a varying range of<br>operating power voltage, not a continuous<br>voltage.<br>● Shock Malfunction<br>Energized De-energized<br>(a contact) Y600 (b contact) Y600<br>400 400<br>X Z X Z<br>600 600 600 600<br>200 400 200 400<br>400 400<br>200 200 200 200<br>200 200<br>200 200 500 200 200 400<br>400 600 400 600<br>Z' X' Z' X'<br>600 400 600 400<br>Shock direction<br>X X'<br>600 600 Y<br>Y' Unit: m/s [2] Y' Unit: m/s [2] Z<br>Z'<br>Y'<br>(coil)<br>4 operations)Durability (× 10 4 operations)Durability (x 10<br>Maximum coil voltage (%) Must Operate and Must Release voltages (%)<br>**----- End of picture text -----**<br> **Operate and Must Release voltages** ## **Magnetic Interference (between Relays)** **==> picture [146 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>2<br>1 max.<br>X<br>0 min.<br>l2 Sample<br>-1<br>l1<br>-2<br>(Mounting pitch)<br>-3<br>Initial l1=2.54a l1=5.08a l1=7.62a<br>l2=5.08a l2=7.62a l2=10.16a<br>Change rate on the basis of rated value (OV) (%)<br>**----- End of picture text -----**<br> Sample: G6C-2114P-US DC24V Number of Relays: 6 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: 100 m/s[2] **5** G6C **PCB Power Relay** ## ■ **Dimensions** ## **Flux Protection Model** **G6C-** @ **117P-US** **==> picture [96 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> G<br>6<br>C Fully Sealed Model<br>G6C- @ 114P-US<br>**----- End of picture text -----**<br> **==> picture [411 x 480] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Mounting Holes Terminal<br>(Bottom View) Arrangement/<br>Tolerance: ±0.1 Internal Connections<br>1-pole (Bottom View)<br>2.54<br>Four, 1.1-dia. holes<br>1-pole<br>2.54<br>1 3 4<br>−<br>20 max. 15 max.<br>(19.9)* (14.9)*<br>+<br>(2.4) 8<br>10 max.<br>0.3 (9.9)*<br>1 0.16 7 .62<br>3.5 (1.1)<br>0.65<0.7> 0.9<1.0> <0.50.4> 2-pole 2.54<br>10.160.9<1.0> 1.11 1 0.16 Six, 1.1-dia. holes<br>7.62 2-pole<br>2.54<br>* Average value 1 3 4<br>−<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket(-P6C).<br>+<br>(2.4) 8 6 5<br>1 0.16 7 .62 Note: Check carefully the coil<br>(1.1) polarity of the Relay.<br>Note: Orientation mark is indicated as follows:<br>PCB Mounting Holes Terminal Arrangement/<br>1-pole (Bottom View) Internal Connections<br>Tolerance: ±0.1 (Bottom View)<br>2.54<br>Four, 1.1-dia. holes 1-pole<br>2.54<br>1 3 4<br>−<br>20 max. 15 max. +<br>(2.4) 8<br>(19.9)* (14.9)*<br>10 max. 1 0.16 7 .62<br>0.3 (9.9)* (1.1)<br>2-pole<br>3.5 2.54<br>0.65<0.7> 0.9<1.0> 0.9<1.0> <0.4>0.5 2.54 Six, 1.1-dia. holes 2-pole<br>10.16 1.11 1 0.16<br>7.62 1 3 4<br>* Average value −<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket(-P6C). +<br>(2.4) 8 6 5<br>1 0.16 7 .62 Note: Check carefully the coil<br>(1.1) polarity of the Relay.<br>**----- End of picture text -----**<br> **6** G6C **PCB Power Relay** **==> picture [545 x 489] intentionally omitted <==** **----- Start of picture text -----**<br> Flux Protective PCB Mounting Holes Terminal<br>Single-winding Latching Model 1-pole (Bottom View)Tolerance: ±0.1 Arrangement/Internal Connections<br>G6CU- @ 117P-US 2.54<br>Four, 1.1-dia. holes<br>1-pole<br>2.54<br>1 3 4<br>− +<br>S R<br>20 max. 15 max.<br>(19.9)* (14.9)* (2.4) 8 + −<br>10 max. S: Set coil<br>0.3 (9.9)* 1 0.16 7 .62 (1.1) R: Reset coil<br>3.5<br>0.65<0.7> 0.9<1.0> 0.5 2-pole<br>0.9<1.0> <0.4> 2.54<br>10.16 7.62 1.11 1 0.16 Six, 1.1-dia. holes 2-pole<br>* Average value 2.54<br>1 3 4<br>Dimensions in pointed brackets < > are for the − +<br>Relay mounted to Socket(-P6C). S R<br>(2.4) 8 + − 6 5<br>1 0.16 7 .62 Note: Check carefully the coil<br>(1.1) polarity of the Relay.<br>Fully Sealed Model PCB Mounting Holes Terminal<br>Single Latching Models 1-pole (Bottom View)Tolerance: ±0.1 Arrangement/Internal Connections G6<br>G6CU- @ 114P-US 2.54 C<br>Four, 1.1-dia. holes<br>1-pole<br>2.54<br>1 3 4<br>− +<br>S R<br>20 max. 15 max.<br>(19.9)* (14.9)* (2.4) 8 + −<br>10 max. S: Set coil<br>0.3 (9.9)* 1 0.16 7 .62 R: Reset coil<br>(1.1)<br>3.5<br>0.5 2-pole<br>0.65<0.7> 0.9<1.0> <0.4><br>0.9<1.0> 2.54<br>10.16 7.62 1.11 1 0.16 Six, 1.1-dia. holes 2-pole<br>* Average value 2.54<br>1 3 4<br>Dimensions in pointed brackets < > are for the − +<br>Relay mounted to Socket(-P6C). S R<br>(2.4) 8 + − 6 5<br>1 0.16 7 .62 Note: Check carefully the coil<br>(1.1) polarity of the Relay.<br>**----- End of picture text -----**<br> Note: Orientation marks are indicated as follows: **7** G6C **PCB Power Relay** **==> picture [512 x 481] intentionally omitted <==** **----- Start of picture text -----**<br> Flux Protective PCB Mounting Holes Terminal Arrangement/<br>Double-winding Latching Model 1-pole (Bottom View)Tolerance: ±0.1 Internal Connections (Bottom View)<br>G6CK- @ 117P-US<br>2.54<br>Six, 1.1-dia. holes<br>1-pole<br>2.54<br>1 2 3 4<br>− −<br>S R<br>20 max. 15 max. + +<br>(2.4) 8 7<br>(19.9)* (14.9)*<br>S: Set coil<br>10 max. 2.54 7 .62 7 .62 R: Reset coil<br>0.3 (9.9)* (1.1)<br>0.9 3.5 2-pole<br>0.65<0.7> <1.0>0.9<1.0> 0.9<1.0> <0.4>0.5 2.54 Eight, 1.1-dia. holes<br>10.16 7.62 1.11 1 0.16 2-pole<br>2.54<br>* Average value 1 2 3 4<br>− −<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket(-P6C). S R<br>+ +<br>(2.4) 8 7 6 5<br>7 .62 7 .62 Note: Check carefully the coil<br>2.54 (1.1) polarity of the Relay.<br>Fully Sealed PCB Mounting Holes Terminal Arrangement/<br>(Bottom View) Internal Connections<br>Double-winding Latching Model 1-pole Tolerance: ±0.1 (Bottom View)<br>G6CK- @ 114P-US 2.54<br>Six, 1.1-dia. holes<br>1-pole<br>2.54<br>1 2 3 4<br>− −<br>S R<br>20 max. (19.9)* 15 max. (14.9)* (2.4) 8 + 7 +<br>S: Set coil<br>0.3 10 max. (9.9)* 2.54 7 .62 7 .62 (1.1) R: Reset coil<br>3.5<br>0.9 2-pole<br>0.65<0.7> <1.0>0.9<1.0> 0.9<1.0> <0.4>0.5 2.54 Eight, 1.1-dia. holes<br>10.16 7.62 1.11 1 0.16 2-pole<br>2.54<br>* Average value 1 2 3 4<br>− −<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket(-P6C). S R<br>+ +<br>(2.4) 8 7 6 5<br>7 .62 7 .62 Note: Check carefully the coil<br>2.54 (1.1) polarity of the Relay.<br>**----- End of picture text -----**<br> **==> picture [151 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> G Double-winding Latching Model<br>6<br>G6CK- @ 114P-US<br>C<br>**----- End of picture text -----**<br> **8** G6C **PCB Power Relay** ## ■ **Connecting Sockets Dimensions** **Socket for single-winding latching/single-side a table Models** P6C-06P **==> picture [515 x 307] intentionally omitted <==** **----- Start of picture text -----**<br> 23.2max. PCB Mounting Holes<br>(23)* (BOTTOM VIEW)<br>Tolerance: [±0.1 mm]<br>15max.(14.9)* oc 3.1 2.54 Six, 1.1-dia. holes<br>2.54<br>(2.4)<br>10.8max.<br>(10.6)* 7.5<br>3.5<br>0.8 0.4 (2.61) 10.16 7 .62<br>10.16 7.62<br>* Average value 10.16 [±0.1]<br>Socket for double-winding latching Models<br>23.2max.(23)* PCB Mounting Holes<br>(BOTTOM VIEW)<br>Tolerance: [±0.1 mm]<br>15max.(14.9)* 3.1 2.54 Eight, 1.1-dia. holes G6<br>C<br>2.54<br>(Ae es SrES EE SR EE T a<br>10.8max. (2.4)<br>(10.6)* 7.5 m. .<br>3.5<br>0.8 0.4 (2.61) 7 .62 7 .62<br>mee * Average value 2.54 7.62 7.62 10.16 [±0.1] 2.54 + 4<br>**----- End of picture text -----**<br> **Socket for double-winding latching Models** P6C-08P Note: Orientation marks are indicated as follows: **9** G6C **PCB Power Relay** ## ■ **Removal Tool** ## **P6B-Y1** ## ■ **Hold-down Clips** ## **P6B-C2** ## ■ **Approved Standards** ● The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. **UL Recognized** (File No. E41643) G 6 C |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6C ( )|1|3 to 24 VDC|10 A, 250 VAC 80°C<br>10 A, 30 VDC 80°C<br>1/6 HP 250 VAC, 1/4 HP, 125 VAC 80°C<br>1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC,(Tungsten)80°C|6,000| ||||530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC(Pilot Duty)80°C|| ||||12 LRA, 2.2 FLA 30 VDC 80°C|30,000| ||2||8 A, 250 VAC 80°C<br>8 A, 30 VDC 80°C<br>1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C<br>1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC(Tungsten)80°C|6,000| ||||530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC(Pilot Duty)80°C|| ||||12 LRA, 2.2 FLA, 30 VDC 80°C|30,000| **CSA Certified** (File No. LR31928) |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6C ( )|1|3 to 24 VDC|10 A, 250 VAC 80°C<br>10 A, 30 VDC 80°C<br>1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C<br>1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC,(Tungsten)80°C|6,000| ||||530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC(Pilot Duty)80°C|| ||2||8 A, 250 VAC 80°C<br>8 A, 30 VDC 80°C<br>1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C<br>1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC(Tungsten)80°C|| ||||530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC(Pilot Duty)80°C|| **EN/IEC, VDE Certified** (Certificate No. 40014439) |Model|Number of<br>poles|Coil ratings|Contact ratings|Approved<br>switching<br>operations| |---|---|---|---|---| |G6C ( )|1|3, 5, 6, 12, 24 VDC|10 A, 250 VAC (cosφ= 1) 40°C<br>5 A, 250 VAC(cosφ= 0.4)40°C|20,000| ||2|• Single-stable:<br>3, 5, 6, 12, 24 VDC|7 A, 250 VAC (cosφ= 1) 40°C<br>3.5 A, 250 VAC (cosφ= 0.4) 40°C|| |**EN/IEC,**|**TÜV Certified**<br> (Registration No. R50158249)|||| |Model|Number of<br>poles|Coil ratings|Contact ratings|Approved<br>switching<br>operations| |G6C ( )|1|• Single-stable:<br>3, 5, 6, 12, 24 VDC<br>• Latching:<br>3, 5, 6, 12, 24 VDC|10 A, 250 VAC (cosφ= 1) 40°C<br>5 A, 250 VAC (cosφ= 0.4) 40°C<br>10 A, 30 VDC(L/R = 0 ms)40°C|20,000| ||2||8 A, 250 VAC (cosφ= 1) 40°C<br>3.5 A, 250 VAC (cosφ= 0.4) 40°C<br>8 A, 30 VDC(L/R = 0 ms)40°C|| **10** G6C **PCB Power Relay** ## ■ **Precautions** - **Please refer to “PCB Relays Common Precautions” for correct use.** ## Correct Use ## ● **Mounting** - Do not reverse the polarity of the coil (+, −). - When mounting more than two relays side by side, keep the gap between Relays as shown below to ensure a good heat dissipation. It may result in malfunction if heat is not dissipated smoothly from the Relay. **==> picture [114 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> 2.54 mm ×<br>3 pitch min.<br>between<br>terminals<br>2.54 mm × 2 pitch min. between terminals<br>**----- End of picture text -----**<br> ## ● **Sockets** **==> picture [63 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> 17 mm max. for sockets<br>7.5 mm<br>**----- End of picture text -----**<br> - When mounting the Relay, make sure to insert the Relay terminals perpendicularly and correctly into the socket contact pin. - Hold-down clips (for mounting and removal) are also available. - The P6C model has a flux-resistant construction. Do not wash it down with water. - The max. carry current of sockets is 5A. ## ● **Double-winding Latching Circuit** - It is recommended to perform wiring of No.1 and No.2 of the negative (-) terminal as COM wiring, in order to improve the operation stability for Double-winding Latching. - **Using SPDT contact of the SPST-NO+SPST-NC Relay** - Do not construct a circuit so that overcurrent and burning occur if the NO, NC and SPDT contacts are shortcircuited with the SPST-NO+SPST-NC Relay. Arcing may generate shortcircuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. ## ● **Other precautions** - This Relay is a Power Relay which is suitable for power load switching. Do G 6 - not use the G6C for signal purposes C such as micro load switching under 10 mA. **==> picture [63 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> (+)<br>+ 8 + 7<br>S R<br>− 1 − 2<br>COM<br>**----- End of picture text -----**<br> - Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. - Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. **Note: Do not use this document to operate the Unit.** ## **OMRON Corporation** **Contact: www.omron.com/ecb** **Electronic and Mechanical Components Company** **Cat. No. K018-E1-09** 0316(0207)(O) **11**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →