G6C-2117P-US-DC12
Power Relay, SPST-NO, SPST-NC, 12 VDC, 8 A, G6C Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 12VDC
- Product Range: G6C Series
- Relay Mounting: Through Hole
- Coil Resistance: 720ohm
- Contact Current: 8A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPST-NO, SPST-NC
| Delivery and price | |
|---|---|
| Units per pack | 60 |
| Price | 4.72 € |
| Current stock | 25+ |
| Lead time | 9 days |
G6C PCB Power Relay G 6 C ## **Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A** - SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and output that satisfy the needs for space-saving. - Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H). - Low power consumption: 200 mW. - Ultrasonically cleanable models is available. - Exclusive P6C model for sockets is now available. ## **RoHS Compliant** ## ■ **Model Number Legend** G6C-@ - @@ @@@-@- @-@-@ 1 2 3 4 5 6 7 8 9 ## **1. Relay Function** None: Single-side stable - U : Single-winding latching K : Double-winding latching ## **2. Contact Form** - 11: SPST-NO (1a) - 21: SPST-NO (1a) + SPST-NC (1b) ## **3. Contact Type** - 1: Single ## **4. Enclosure rating** - 4: Fully sealed - 7: Flux protection ## **5. Terminal Shape** - P: PCB terminals Socket mounting Terminals ## **6. Contact Material** None: Standard (Ag-alloy (Cd free)) FD : AgSnIn Contacts (Suitable for DC inductive load with high inrush current) ## **7. Approved Standards** US: UL/CSA ## **8. Washability** None: Standard model (not compatible with ultrasonically cleanable models) - U : For ultrasonically cleanable ## **9. Mounting** None: Mounted directly to PCB P6C : Mounted to Socket ## ■ **Application Examples** Ideal for output applications of control equipments C: Self-clinching PCB **1** G6C **PCB Power Relay** G 6 C ## ■ **Ordering Information** ## ● **Standard Models (UL, CSA certified)** |||Relay Function|Single-side stable|Single-side stable|Single-winding latching|Single-winding latching|Double-winding latching|Double-winding latching|Minimun<br>packing<br>unit| |---|---|---|---|---|---|---|---|---|---| |Enclosure<br>rating|Contact form|Terminals|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|| |Flux<br>protection|SPST-NO (1a)|Straight PCB|**G6C-1117P-US**|3 VDC|**G6CU-1117P-US**|3 VDC|**G6CK-1117P-US**|3 VDC|100 pcs/<br>tray| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||−||6 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||24 VDC|| ||||**G6C-1117P-FD-US**|5 VDC|**G6CU-1117P-FD-US**|5 VDC|**G6CK-1117P-FD-US**|−|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||−|| |||Self-clinching<br>PCB|<br>**G6C-1117C-US**|3 VDC|−|−|**G6CK-1117C-US**|−|| |||||5 VDC||−||−|| |||||12 VDC||−||12 VDC|| |||||24 VDC||−||24 VDC|| ||SPST-NO (1a) +<br>SPST-NC (1b)|<br>Straight PCB|**G6C-2117P-US**|3 VDC|**G6CU-2117P-US**|3 VDC|**G6CK-2117P-US**|3 VDC|| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||6 VDC||6 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||24 VDC|| ||||**G6C-2117P-FD-US**|5 VDC|**G6CU-2117P-FD-US**|5 VDC|**G6CK-2117P-FD-US**|5 VDC|| |||||12 VDC||12 VDC||−|| |||||24 VDC||24 VDC||24 VDC|| |||Self-clinching<br>PCB|<br>**G6C-2117C-US**|3 VDC|**G6CU-2117C-US**|−|**G6CK-2117C-US**|3 VDC|| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||−||−|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||−||24 VDC|| ||||||||||| |||Relay Function|Single-side stable||Single-winding latching||Double-winding latching||Minimun<br>packing<br>unit| |Enclosure<br>rating|Contact form|Terminals|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|| |Fully<br>sealed|SPST-NO (1a)|Straight PCB|**G6C-1114P-US**|3 VDC|**G6CU-1114P-US**|3 VDC|**G6CK-1114P-US**|3 VDC|100 pcs/<br>tray| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||6 VDC||6 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||24 VDC|| ||||**G6C-1114P-FD-US**|5 VDC|**G6CU-1114P-FD-US**|5 VDC|**G6CK-1114P-FD-US**|5 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||24 VDC|| |||Self-clinching<br>PCB|<br>**G6C-1114C-US**|3 VDC|**G6CU-1114C-US**|−|**G6CK-1114C-US**|3 VDC|| |||||5 VDC||−||5 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||−||24 VDC|| ||SPST-NO (1a) +<br>SPST-NC (1b)|<br>Straight PCB|**G6C-2114P-US**|3 VDC|**G6CU-2114P-US**|3 VDC|**G6CK-2114P-US**|3 VDC|| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||6 VDC||6 VDC|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||24 VDC||24 VDC|| ||||**G6C-2114P-FD-US**|5 VDC|**G6CU-2114P-FD-US**|5 VDC|**G6CK-2114P-FD-US**|−|| |||||12 VDC||12 VDC||−|| |||||24 VDC||24 VDC||24 VDC|| |||Self-clinching<br>PCB|<br>**G6C-2114C-US**|3 VDC|**G6CU-2114C-US**|−|**G6CK-2114C-US**|−|| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||−||6 VDC|| |||||12 VDC||−||12 VDC|| |||||24 VDC||−||24 VDC|| Note. When ordering, add the rated coil voltage to the model number. Example: G6C-1117P-US DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. **2** G6C **PCB Power Relay** G 6 C ## ● **Ultrasonically Cleanable Models (UL, CSA certified)** |||Relay Function|Single-side stable|Single-side stable|Single-winding latching|Single-winding latching|Double-winding|latching|Minimun<br>packing<br>unit| |---|---|---|---|---|---|---|---|---|---| |Enclosure<br>rating|Contact form|Terminals|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|Model|Rated coil<br>voltage|| |Fully sealed|SPST-NO (1a)|Straight PCB|**G6C-1114P-US-U**|3 VDC|**G6CU-1114P-US-U**|−|**G6CK-1114P-US-U**|−|100 pcs/<br>tray| |||||5 VDC||5 VDC||5 VDC|| |||||6 VDC||−||−|| |||||12 VDC||12 VDC||12 VDC|| |||||24 VDC||−||24 VDC|| |||Self-clinching<br>PCB|**G6C-1114C-US-U**|12 VDC|−|−|−|−|| |||||24 VDC||−||−|| ||SPST-NO (1a) +<br>SPST-NC (1b)|<br>Straight PCB|**G6C-2114P-US-U**|5 VDC|−|−|**G6CK-2114P-US-U**|5 VDC|| |||||12 VDC||−||12 VDC|| |||||24 VDC||−||−|| |||Self-clinching<br>PCB|**G6C-2114C-US-U**|5 VDC|−|−|−|−|| |||||12 VDC||−||−|| |||||24 VDC||−||−|| Note. When ordering, add the rated coil voltage to the model number. Example: G6C-1114P-US-U DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ## ● **Connecting Sockets (Sold Separately)** |Applicable relays|Model|Minimun packing unit| |---|---|---| |G6C-2114P-US-P6C<br>G6C-2117P-US-P6C<br>G6C-1114P-US-P6C<br>G6C-1117P-US-P6C<br>G6CU-2114P-US-P6C<br>G6CU-2117P-US-P6C<br>G6CU-1114P-US-P6C<br>G6CU-1117P-US-P6C|**P6C-06P**|20 pcs/tube| |G6CK-2114P-US-P6C<br>G6CK-2117P-US-P6C<br>G6CK-1114P-US-P6C<br>G6CK-1117P-US-P6C|**P6C-08P**|| |Removal Tool|**P6B-Y1**|1| |Hold-down Clips|**P6B-C2**|| Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket. 2. When using by combining sockets, the rated current will be 5A due to its rated switching current. **3** G6C **PCB Power Relay** G 6 C ## ■ **Ratings** ## **Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)** |Item|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must operate<br>voltage<br>(V)|Must release<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power<br>consumption<br>(mW)| |---|---|---|---|---|---|---| |Rated voltage|||% of rated voltage|||| |3 VDC|67|45|70% max.|10% min.|160%<br>(at 23°C)|Approx. 200| |5 VDC|40|125||||| |6 VDC|33.3|180||||| |12 VDC|16.7|720||||| |24 VDC|8.3|2,880||||| ## **Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)** |Item|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must set<br>voltage<br>(V)|Must reset<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---| |Rated voltage||||||Set coil<br>(mW)|Reset coil<br>(mW)| ||||% of rated voltage||||| |3 VDC|67|45|70% max.|70% max.|160%<br>(at 23°C)|200|200| |5 VDC|40|125|||||| |6 VDC|33.3|180|||||| |12 VDC|16.7|720|||||| |24 VDC|8.3|2,880|||||| ## **Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)** |Item|Rated current (mA)|Rated current (mA)|Coil resistance (Ω)|Coil resistance (Ω)|Must set<br>voltage<br>(V)|Must reset<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---|---|---| |Rated voltage|Set coil|Reset coil|Set coil|Reset coil||||Set coil<br>(mW)|Reset coil<br>(mW)| ||||||% of rated voltage||||| |3 VDC|93.5|93.5|32.1|32.1|70% max.|70% max.|130%<br>(at 23°C)|280|280| |5 VDC|56.0|56.0|89.3|89.3|||||| |6 VDC|46.7|46.7|129|129|||||| |12 VDC|23.3|23.3|514|514|||||| |24 VDC|11.7|11.7|2,056|2,056|||||| - Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. - 2.The operating characteristics are measured at a coil temperature of 23°C. - 3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ## **Contact** |Contact Form<br>Rated load<br>Item|SPST-NO (1a)|SPST-NO (1a)|SPST-NO (1a) + SPST-NC (1b)|SPST-NO (1a) + SPST-NC (1b)| |---|---|---|---|---| ||Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)|Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)| ||10 A (8 A) at 250 VAC<br>10 A (10 A) at 30 VDC|5 A (5 A) at 250 VAC<br>5 A (5 A) at 30 VDC|8 A (8 A) at 250 VAC<br>8 A (8 A) at 30 VDC|3.5 A (3.5 A) at 250 VAC<br>3.5 A (3.5 A) at 30 VDC| |Contact type|Single|||| |Contact material|Ag-Alloy (Cd free)|||| |Rated carry current|10 A (10 A)||8 A (8 A)|| |Max. switching voltage|380 VAC, 125 VDC|||| |Max. switching current|10 A (10 A)||8 A (8 A)|| Note. The values shown in parentheses ( ) are for -FD models only. **4** G6C **PCB Power Relay** G 6 C ## ■ **Characteristics (Including models for ultrasonically cleanable)** |Item<br>Classification<br>Si|Item<br>Classification<br>Si|ngle-side Stable|Single-windingLatching<br>D|ouble-windingLatching|Note. The given values are initial values.<br>*1.<br>Measurement conditions: 5 VDC, 1 A, voltage<br>drop method.<br>*2.<br>Testing conditions: measured with a 500 VDC<br>megohmmeter (at 250 VDC between set/reset<br>coil).<br>*3.<br>This value was measured at a switching<br>frequency of 120 operations/min.| |---|---|---|---|---|---| |Contact resistance *1||30 mΩmax.|||| |Operate(set)time||10 ms max.|||| |Release(reset)time||10 ms max.|||| |Min. setpulse width||−|20 ms(at 23°C)||| |Min. resetpulse width||−|20 ms(at 23°C)||| |Insulation<br>resistance *2|Between coil and<br>contacts|1,000 MΩmin.|||| ||Between contacts of the<br>samepolarity|1,000 MΩmin.|||| ||Between contacts of<br>differentpolarity|1,000 MΩmin. (SPST-NO, SPST-NC)|||| ||Between set and reset<br>coils|−|−|1,000 MΩmin.|| |Dielectric<br>strength|Between coil and<br>contacts|2,000 VAC 50/60Hz for 1min|||| ||Between contacts of the<br>samepolarity|1,000 VAC 50/60Hz for 1min|||| ||Between contacts of<br>differentpolarity|2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC)|||| ||Between set and reset<br>coils|−|−|250 VAC 50/60Hz for<br>1min|| |Vibration<br>resistance|Destruction<br>10|to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)|||| ||Malfunction<br>10|to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)|||| |Shock<br>resistance|Destruction|1,000 m/s2|||| ||Malfunction|100 m/s2|||| |Durability|Mechanical|50,000,000 operations min.(at 18,000 operations/hr)|||| ||Electrical|100,000 operation min.(at 1,800 operations/hr under rated load)|||| |Failure rate(P level) (reference value)*3||10 mA at 5 VDC|||| |Ambient operatingtemperature||-25°C to 70°C(with no icingor condensation)|||| |Ambient operatinghumidity||5% to 85%|||| |Weight||Approx. 5.6g|||| ## ■ **Engineering Data** ## ● **Maximum Switching Capacity** **==> picture [334 x 358] intentionally omitted <==** **----- Start of picture text -----**<br> G6C-1114 @ -US G6C-1114 @ -FD-US<br>G6C-1117 @ -US G6C-1117 @ -FD-US<br>50 50<br>30 30<br>AC resistive load AC resistive load<br>10 10<br>7 8<br>5 5<br>3 DC resistive load AC inductive 3 AC inductive<br>load 2 DC resistive load load<br>DC inductive load (cosφ = 0.4) (cosφ = 0.4)<br>1 (L/R = 7 ms) 1 DC inductive load<br>0.7 0.7 (L/R = 7 ms)<br>0.5 0.5<br>0.3 0.3<br>0.2 0.2<br>0.1 0.1<br>1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000<br>Switching voltage (V) Switching voltage (V)<br>G6C-2114 @ -US G6C-2114 @ -FD-US<br>G6C-2117 @ -US G6C-2117 @ -FD-US<br>50 50<br>30 30<br>AC resistive load AC resistive load<br>10 10<br>8 8<br>5 5<br>3 3<br>2 DC resistive load AC inductive 2 AC inductive<br>1 DC inductive load (L/R = 7 ms) load(cosφ = 0.4) 1 DC resistive load load(cosφ = 0.4)<br>0.7 0.7 DC inductive load<br>0.5 0.5 (L/R = 7 ms)<br>0.3 0.3<br>0.2 0.2<br>0.1 0.1<br>1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000<br>Switching voltage (V) Switching voltage (V)<br>Switching current (A) Switching current (A)<br>Switching current (A) Switching current (A)<br>**----- End of picture text -----**<br> **5** **PCB Power Relay** ## G6C ## ● **Durability** ## **G6C-1114** @ **-US, G6C-2114** @ **-US G6C-1117** @ **-US, G6C-2117** @ **-US** ## **G6C-1114** @ **-FD-US, G6C-2114** @ **-FD-US G6C-1117** @ **-FD-US, G6C-2117** @ **-FD-US** **==> picture [529 x 532] intentionally omitted <==** **----- Start of picture text -----**<br> 500 500<br>G6C-2114@-FD-US<br>300 300 G6C-2117@-FD-US<br>250 VAC resistive G6C-1114@-FD-US<br>30 VDC resistive G6C-1117@-FD-US<br>100 G6C-2114 G6C-2117 @ @ -US -US 100 250 VAC resistive<br>250 VAC resistive G6C-1114@-US G6C-1114@<br>50 30 VDC resistive G6C-1117@-US 50 -FD-US<br>30 30 VDC resistive250 VAC resistive 30 G6C-FD-US-1117@<br>30 VDC resistive<br>10 10<br>531 (L/R = 7 ms) 30 VDC inductive(cosG6C-2117250 VAC inductiveG6Cφ-2114 = 0.4)@@--USUS (L/R = 7 ms)(cos 30 VDC inductiveG6C-1114 G6C-1117250 VAC inductiveφ = 0.4) @ @ -US -US 531 G6C-2114 G6C-2117 (L/R = 7 ms) 250 VAC inductive (cos30 VDC inductive φ = 0.4)@ @ -FD-US -FD-US (L/R = 7 ms)30 VDC inductive ( 250 VAC inductive G6C-1117G6C cosφ -1114 = 0.4 @@ ) -FD-US-FD-US<br>0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11<br>Switching current (A) Switching current (A)<br>● Ambient Temperature vs. ● Ambient Temperature vs Must<br>Maximum Coil Voltage Operate and Must Release voltages<br>200 100 Sample: Must operate voltage<br>G6C-114P-US Must release voltage<br>180 Number of Relays: max.<br>80 5 pcs X<br>G 160 min.<br>6 140 60<br>C 130<br>120<br>40<br>max.<br>100 X<br>20 min.<br>80<br>60 0<br>10 20 23 30 40 50 60 70 80 90 -40 -20 0 20 40 60 80<br>Ambient temperature (°C) Ambient temperature (°C)<br>Note. The maximum coil voltage refers to the<br>maximum value in a varying range of<br>operating power voltage, not a continuous<br>voltage.<br>● Shock Malfunction ● Magnetic Interference (between Relays)<br>Energized (a contact) Y600 De-energized (b contact) Y600 3<br>2<br>400 400<br>X Z X Z<br>600 200 400 600 600 200 400 600 1 max.<br>400 400<br>200 200 200 200 X<br>200 200 0 min.<br>200 200 500 200 200 400 l2 Sample<br>400 600 400 600 -1<br>Z'600 400 X' Z'600 400 X' l1<br>Shock direction<br>-2<br>X X'<br>600 600 Y<br>Y' Unit: m/s [2] Y' Unit: m/s [2] Z -3 (Mounting pitch)<br>Z' Initial l1=2.54a l1=5.08a l1=7.62a<br>Y' l2=5.08a l2=7.62a l2=10.16a<br>(coil)<br>4 operations)Durability (× 10 4 operations)Durability (x 10<br>Maximum coil voltage (%) Must Operate and Must Release voltages (%)<br>Change rate on the basis of rated value (OV) (%)<br>**----- End of picture text -----**<br> ## ● **Magnetic Interference (between Relays)** Sample: G6C-2114P-US DC24V Number of Relays: 6 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: 100 m/s[2] **6** G6C **PCB Power Relay** ## ■ **Dimensions** **==> picture [526 x 525] intentionally omitted <==** **----- Start of picture text -----**<br> Flux Protection Model<br>PCB Mounting Holes Terminal Arrangement/<br>(Straight PCB) (Bottom View) Internal Connections<br>G6C- @ 117P (-FD) -US P| 20 max.(19.9)* Po 15 max(14.9)*. Tolerance: ±0.1 (Bottom View)<br>1-pole<br>10 max. 2.54<br>0.3 (9.9)* Four, 1.1-dia. holes<br>1-pole<br>2.54<br>Ter 8, =I 3.5 COLEEEE<br>1 3 4<br>0.65<0.7> 0.9<1.0> <0.50.4> −<br>0.9<1.0><br>. 10.16 7.62 L 1.11 1 0.16 : C eCe 4 + |<br>(2.4) 8<br>* Average value C OPE oO<br>Dimensions in pointed brackets < > are<br>for the Relay mounted to Socket (-P6C). ok 1 0.16 7 .62<br>(1.1)<br>Flux Protection Model<br>2-pole<br>(Self-clinching PCB) 2.54<br>G6C- @ 117C-US 20 max.(19.9)* 15 max.(14.9)* 2. so 54 Six, 1.1-dia. holes , 2-pole<br>1 3 4<br>10 max. −<br>0.3 (9.9)*<br>3.2 3.5 (0.8)* (2.4) 8 + 6 5<br>(1.0)*<br>0.65 0.9 0.5<br>0.9<br>10.16 7.62 H 1.11 1 0.16 a ok 1 0.16 7 .62 Note: Check carefully the coil G<br>(1.1) polarity of the Relay.<br>6<br>* Average value<br>C<br>Fully Sealed Model PCB Mounting Holes Terminal Arrangement/<br>(Straight PCB) G6C- @ 114P (-FD) -US Pe 20 max.(19.9)* P| 15 max.(14.9)* 10 max. 1-pole2.54 (Bottom View)Tolerance: ±0.1Four, 1.1-dia. holes Internal Connections (Bottom View)1-pole<br>0.3 (9.9)* 2.54<br>a a 3.5 | a e e ne ey 1 − 3 4<br>0.65<0.7> 0.9<1.0> 0.9<1.0> <0.4>0.5 +<br>(2.4) 8<br>10.16 1.11 1 0.16<br>7.62<br>* Average value oe 1 0.16 7 .62<br>Dimensions in pointed brackets < > are (1.1)<br>for the Relay mounted to Socket (-P6C).<br>2-pole<br>Fully Sealed Model<br>2.54<br>(Self-clinching PCB) 20 max. 15 max. Six, 1.1-dia. holes<br>G6C- @ 114C-US — (19.9)* (14.9)* 2. we 54 | 2-pole<br>1 3 4<br>10 max. −<br>0.3 (9.9)*<br>Be 3.2 3.5 (0.8)* (1.0)* ss ES (2.4) 8 + 6 5<br>0.65 0.9 0.5<br>10.16 0.9 1.11 1 0.16 Note: Check carefully the coil<br>ae UE 7.62 Eh bee 1 0.16 7 .62 polarity of the Relay.<br>* Average value (1.1)<br>Note: Orientation marks are indicated as follows:<br>**----- End of picture text -----**<br> **7** G6C **PCB Power Relay** ## **Flux Protective** **==> picture [522 x 536] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Mounting Holes Terminal Arrangement/<br>Single-winding Latching Model (Bottom View) Internal Connections<br>(Straight PCB) 20 max. 15 max. Tolerance: ±0.1 (Bottom View)<br>G6CU- @ 117P (-FD) -US Pe (19.9)* Po (14.9)* 1-pole<br>10 max. 2.54<br>P | PF 0.3 (9.9)* Four, 1.1-dia. holes 1-pole<br>2.54<br>3.5 1 3 4<br>− +<br>0.65<0.7 > 0.9<1.0> 0.5<br>0.9<1.0> <0.4> S R<br>Ge e 10.16 e 7.62 1.11 1 0.16 casita (2.4) ee 8 + −<br>* Average value<br>S: Set coil<br>Dimensions in pointed brackets < > ok 1 0.16 7 .62 R: Reset coil<br>are for the Relay mounted to Socket (-P6C). (1.1)<br>Flux Protective<br>2-pole<br>Single-winding Latching Model 2.54<br>(Self-clinching PCB) — 20 max. 15 max. yr Six, 1.1-dia. holes | 2-pole<br>G6CU- @ 117C-US (19.9)* (14.9)* 2.54<br>1 3 4<br>− +<br>10max.<br>0.3 (9.9)* S R<br>3.2 3.5 (0.8)* (2.4) 8 + − 6 5<br>(1.0)*<br>0.65 0.9 0.9 0.5 Note: Check carefully the coil<br>10.16 1.11 1 0.16 1 0.16 7 .62<br>ee 7.62 | HEE (1.1) polarity of the Relay.<br>G * Average value<br>6<br>C Fully Sealed Model PCB Mounting Holes Terminal Arrangement/<br>Single Latching Models 20 max. 15 max. (Bottom View)Tolerance: ±0.1 Internal Connections (Bottom View)<br>(Straight PCB) (19.9)* (14.9)* 1-pole<br>G6CU- @ 114P (-FD) -US Pe i “|_, 2.54<br>10 max. Four, 1.1-dia. holes<br>0.3 (9.9)* 1-pole<br>2.54<br>1 3 4<br>3.5 − +<br>0.5<br>0.65<0.7> 0.9<1.0> <0.4> S R<br>0.9<1.0><br>+ −<br>10.16 7.62 1.11 1 0.16 (2.4) 8<br>U \ * Average value LTT TT Tt yt ty | S: Set coil<br>Dimensions in pointed brackets < > are ok 1 0.16 7 .62 R: Reset coil<br>for the Relay mounted to Socket (-P6C). (1.1)<br>Fully Sealed Model<br>Single Latching Models 2-pole<br>(Self-clinching PCB) 2.54 Six, 1.1-dia. holes<br>G6CU- @ 114C-US 20 max. 15 max. 2-pole<br>_ (19.9)* _ (14.9)* 2. fon 54 e |<br>1 3 4<br>− +<br>10 max.<br>0.3 (9.9)* S R<br>3.2 3.5 (0.8)* (2.4) 8 + − 6 5<br>(1.0)*<br>0.65 0.9 0.9 0.5 Note: Check carefully the coil<br>10.16 1.11 1 0.16 1 0.16 7 .62<br>| i Ci" A 7.62 RA 4 a Heesa (1.1) Ld polarity of the Relay.<br>* Average value<br>**----- End of picture text -----**<br> Note: Orientation marks are indicated as follows: **8** G6C **PCB Power Relay** G 6 C ## **Flux Protective** **==> picture [510 x 546] intentionally omitted <==** **----- Start of picture text -----**<br> Double-winding Latching Model<br>PCB Mounting Holes Terminal Arrangement/<br>(Straight PCB) 20 max. 15 max. (Bottom View) Internal Connections<br>G6CK- @ 117P (-FD) -US (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)<br>PS - | __, 1-pole<br>10 max. 2.54<br>0.3 (9.9)* Six, 1.1-dia. holes<br>1-pole<br>2.54<br>0.9 3.5 1 2 3 4<br><1.0> − −<br>0.65<0.7> 0.5<br>0.9<1.0> 0.9<1.0> <0.4> S R<br>10.16 7.62 1.11 1 0.16 (2.4) 8 + 7 +<br>* Average value<br>S: Set coil<br>Dimensions in pointed brackets < > are 2.54 So a 7 .62 7 .62 R: Reset coil oO<br>for the Relay mounted to Socket (-P6C). (1.1)<br>Flux Protective 2-pole<br>2.54<br>Double-winding Latching Model Eight, 1.1-dia. holes<br>2-pole<br>(Self-clinching PCB) 20 max. 15 max. 2.54 Tr |<br>G6CK- @ 117C-US (19.9)* (14.9)* 1 − 2 − 3 4<br>10 max. S R<br>0.3 (9.9)*<br>+ +<br>(2.4) 8 7 6 5<br>3.2 3.5 (0.8)*<br>0.65 0.9 0.9 0.9 0.5 (1.0)* 7 .62 7 .62 Note: Check carefully the coil<br>Ge rt 10.16 7.62 1.11 1 0.16 Heer 2.54 (1.1) polarity of the Relay.<br>* Average value<br>Fully Sealed<br>Double-winding Latching Model<br>PCB Mounting Holes Terminal Arrangement/<br>(Straight PCB) 20 max. 15 max. (Bottom View) Internal Connections<br>G6CK- @ 114P (-FD) -US (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)<br>P| _ “|__<br>10 max. 1-pole<br>0.3 (9.9)* 2.54<br>Six, 1.1-dia. holes<br>3.5 1-pole<br>0.9 2.54<br>0.65<0.7> <1.0>0.9<1.0> 0.9<1.0> <0.4>0.5 1 − 2 − 3 4<br>O o 10.16 1.11 1 0.16 ee. S R<br>7.62<br>* Average valueDimensions in pointed brackets < > are Cie} LEC (2.4) 8 + 7 +<br>for the Relay mounted to Socket (-P6C).<br>7 .62 7 .62 S: Set coil<br>Oe ah 2.54 (1.1) R: Reset coil<br>Fully Sealed<br>Double-winding Latching Model<br>(Self-clinching PCB) 2-pole2.54<br>G6CK- @ 114C-US 20 max. 15 max. Eight, 1.1-dia. holes 2-pole<br>fC (19.9)* en (14.9)* 2. iP 54<br>1 2 3 4<br>10 max. − −<br>> 0.3 (9.9)* ee ec oe S R<br>3.2 3.5 + +<br>(0.8)* (2.4) 8 7 6 5<br>0.9 (1.0)*<br>0.65 0.9 0.5<br>al * Average value10.16 0.97.62 : 1.11 1 0.16 - EE 2.54 7 .62 7 .62 (1.1) Note: polarity of the Relay. Check carefully the coil<br>**----- End of picture text -----**<br> Note: Orientation marks are indicated as follows: **9** G6C **PCB Power Relay** ## ■ **Connecting Sockets Dimensions** **Socket for single-winding latching/single-side a table Models** P6C-06P **==> picture [518 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> 23.2max. PCB Mounting Holes<br>(23)* (BOTTOM VIEW)<br>Tolerance: [±0.1 mm]<br>15max.(14.9)* ig 3.1 2.54 Six, 1.1-dia. holes<br>2.54<br>(2.4)<br>10.8max.<br>(10.6)* 7.5<br>3.5<br>0.8 0.4 (2.61) 10.16 7 .62<br>m t 10.16 7.62 +. 4<br>* Average value 10.16 [±0.1]<br>Socket for double-winding latching Models<br>P6C-08P<br>23.2max.(23)* PCB Mounting Holes<br>(BOTTOM VIEW)<br>Tolerance: [±0.1 mm]<br>ao<br>G6 15max.(14.9)* 3.1 2.54 Eight, 1.1-dia. holes<br>C<br>2.54<br>(Apt es SrES EE SR ED T a<br>10.8max. (2.4)<br>we (10.6)* 7.5 rete<br>3.5<br>0.8 0.4 (2.61) 7 .62 7 .62<br>a es: * Average value 2.54 7.62 7.62 10.16 [±0.1] 2.54 + 4<br>Note: Orientation marks are indicated as follows:<br>**----- End of picture text -----**<br> **10** G6C **PCB Power Relay** G 6 C ## ■ **Removal Tool** ## **P6B-Y1** ## ■ **Hold-down Clips** ## **P6B-C2** ## ■ **Approved Standards** - ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. **UL Recognized** (File No. E41643) **CSA Certified** (File No. LR31928) |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6C ( )|1|3 to 24 VDC|10 A, 250 VAC (General use) 80°C<br>10 A, 30 VDC (Resistive) 80°C<br>1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C<br>1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models)|6,000| ||||530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC (Pilot Duty) 80°C|6,000| ||||12 LRA, 2.2 FLA, 30 VDC 80°C|30,000<br>1,000 (-FD Models)| ||2||8 A, 250 VAC (General use) 80°C<br>8 A, 30 VDC (Resistive) 80°C<br>1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C<br>1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C<br>600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models)|6,000| ||||530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C<br>43.2 VA, 30 VDC (Pilot Duty) 80°C|6,000| ||||12 LRA, 2.2 FLA, 30 VDC 80°C|30,000<br>1,000 (-FD Models)| **EN/IEC, VDE Certified** (Certificate No. 40014439) |Model|Number of<br>poles|Coil ratings|Contact ratings|Approved switching<br>operations| |---|---|---|---|---| |G6C ( )|1|3, 5, 6, 12, 24 VDC|10 A, 250 VAC (cosφ= 1) 40°C<br>5 A, 250 VAC(cosφ= 0.4)40°C|20,000| ||2|• Single-stable:<br>3, 5, 6, 12, 24 VDC|7 A, 250 VAC (cosφ= 1) 40°C<br>3.5 A, 250 VAC (cosφ= 0.4) 40°C|| ## **EN/IEC, TÜV Certified** (Registration No. R50158249) |Model|Number of<br>poles|Coil ratings|Contact ratings|Approved switching<br>operations| |---|---|---|---|---| |G6C ( )|1|• Single-stable:<br>3, 5, 6, 12, 24 VDC<br>• Latching:<br>3, 5, 6, 12, 24 VDC|10 A, 250 VAC (cosφ= 1) 40°C<br>5 A, 250 VAC (cosφ= 0.4) 40°C<br>10 A, 30 VDC(L/R = 0 ms)40°C|20,000| ||2||8 A, 250 VAC (cosφ= 1) 40°C<br>3.5 A, 250 VAC (cosφ= 0.4) 40°C<br>8 A, 30 VDC(L/R = 0 ms)40°C|| **11** G6C **PCB Power Relay** ## ■ **Precautions** - **Please refer to “PCB Relays Common Precautions” for correct use.** ## Correct Use G 6 C ## ● **Mounting** - Do not reverse the polarity of the coil (+, −). - When mounting more than two relays side by side, keep the gap between Relays as shown below to ensure a good heat dissipation. It may result in malfunction if heat is not dissipated smoothly from the Relay. **==> picture [113 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> 2.54 mm ×<br>3 pitch min.<br>between<br>terminals<br>2.54 mm × 2 pitch min. between terminals<br>**----- End of picture text -----**<br> ## ● **Sockets** **==> picture [62 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> 17 mm max. for sockets<br>7.5 mm<br>**----- End of picture text -----**<br> - When mounting the Relay, make sure to insert the Relay terminals perpendicularly and correctly into the socket contact pin. - Hold-down clips (for mounting and removal) are also available. - The P6C model has a flux-resistant construction. Do not wash it down with water. - The max. carry current of sockets is 5A. - Not applicable to the self-clinching type. - **Double-winding Latching Circuit** - It is recommended to perform wiring of No.1 and No.2 of the negative (-) terminal as COM wiring, in order to improve the operation stability for Double-winding Latching. ## ● **Using SPDT contact of the SPST-NO+SPST-NC Relay** - Do not construct a circuit so that overcurrent and burning occur if the NO, NC and SPDT contacts are shortcircuited with the SPST-NO+SPST-NC Relay. Arcing may generate shortcircuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. - **Other precautions** - This Relay is a Power Relay which is suitable for power load switching. Do not use the G6C for signal purposes such as micro load switching under 10 mA. **==> picture [63 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> (+)<br>+ 8 + 7<br>S R<br>− 1 − 2<br>COM<br>**----- End of picture text -----**<br> Please check each region's Terms & Conditions by region website. ## **OMRON Corporation Electronic and Mechanical Components Company** ## **Regional Contact** **Americas Europe** https://www.components.omron.com/ http://components.omron.eu/ **Asia-Pacific China** https://ecb.omron.com.sg/ https://www.ecb.omron.com.cn/ **Korea Japan** https://www.omron-ecb.co.kr/ https://www.omron.co.jp/ecb/ © OMRON Corporation 2007-2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. K018-E1-11** 0318(0207)(O) **12**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →