G6B-1114P-FD-US-DC24
Power Relay, SPST-NO, 24 VDC, 5 A, G6B Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: G6B Series
- Relay Mounting: Through Hole
- Coil Resistance: 2.88kohm
- Contact Current: 5A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 90 |
| Price | 3.03 € |
| Current stock | 1000+ |
| Lead time | 30 days |
G6B PCB Power Relay G 6 B ## **High Capacity and High Dielectric Strength Miniature Relay with Fully Sealed Construction in 5 A (8 A) SPST-NO(1a), SPST-NO+SPST-NC(1a1b), DPST-NO(2a), DPST-NC(2b) Types** - P6B model for connecting sockets are available. - High insulation with dielectric strength of 3,000VAC between coil and contacts (impulse withstand voltage of 6 kV). - Standard model conforms to UL/CSA standards. - AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) are available. (-FD type) - Ultrasonic cleanable models are available. (-U type) - Operation indicator & built-in surge absorption diode models are available. (-ND type) - 2-Pole type available. - High-reliability models are available. G6B-1184P-US model (The relay used in Terminal Relay G6B-48BND) **RoHS Compliant** ~~[~~ ## ~~ee~~ ■ **Application Examples** • Ideal for output applications of control equipments ## ■ **Model Number Legend** ## G6B @- @@@@@-@ **-** @-@-@-@-@ - **-** 1 2 3 4 5 6 7 8 9 10 11 ## **4. Enclosure rating** ## **1. Relay Function** None: Single-side stable 4: Fully sealed - U : Single-winding latching (G6B @ -1114 models only) - 7: Flux protection ## **5. Terminal Shape** - K : Double-winding latching (G6B @ -1114 models only) - P: Straight PCB terminals Socket mounting terminals - C: Self-clinching PCB ## **2. Contact Form** - 21: SPST-NO + SPST-NC ## **6. Contact material** - 22: DPST-NO None: Standard (Ag-alloy (Cd free)) - 20: DPST-NC FD : AgSnIn contact (Suitable for DC inductive load with high inrush current) - 11: SPST-NO ## **3. Classification** - 1: Standard ## **7. Coil Polarity** - 7: High-capacity None: 5, 6 Terminal (+), 1, 2 Terminal (-) - 8: Single crossbar - 1 : 5, 6 Terminal (-), 1, 2 Terminal (+) ## **8. Operation Indicator Diode Availability** None: Standard ND : Operation indicator & coil surge absorption diode (for -1177 type only) ## **9. Approved Standards** US: UL/CSA ## **10. Washability** None: Standard U : For ultrasonically cleanable ## **11. Mounting** None: Mounted directly to PCB P6B : Mounted to Socket **1** G6B **PCB Power Relay** G 6 B ## ■ **Ordering Information** ## ● **Standard Models (UL, CSA certified)** |Number<br>of poles||Contact material|Contact material|Standard (Ag-alloy (Cd free))|Standard (Ag-alloy (Cd free))|AgSnIn contact|AgSnIn contact|Minimum<br>packing unit| |---|---|---|---|---|---|---|---|---| ||Relay Function|Contact form|Terminals|Model|Rated coil voltage|Model|Rated coil voltage|| |1-pole|Single-side<br>stable|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6B-1114P-US**|5, 6, 12, 24 VDC|**G6B-1114P-FD-US**|5, 6, 12, 24 VDC|100<br>pcs/tray| ||||Self-clinching<br>PCB|**G6B-1114C-US**|5, 6, 12, 24 VDC|**G6B-1114C-FD-US**|12, 24 VDC|| |||SPST-NO (1a)<br>(High-capacity)|Straight PCB|**G6B-1174P-US**|5, 6, 12, 24 VDC|**G6B-1174P-FD-US**|5, 6, 12, 24 VDC|20<br>pcs/tube| ||||Self-clinching<br>PCB|**G6B-1174C-US**|5, 12, 24 VDC|**G6B-1174C-FD-US**|5, 12, 24 VDC|| |||SPST-NO (1a)<br>(High-reliability )|Straight PCB|**G6B-1184P-US**|5, 12, 24 VDC|---|---|100<br>pcs/tray| ||||Self-clinching<br>PCB|---|---|---|---|| ||Single-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BU-1114P-US**|5, 6, 12, 24 VDC|**G6BU-1114P-FD-US**|5, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6BU-1114C-US**|12 VDC|---|---|| ||Double-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BK-1114P-US**|5, 6, 12, 24 VDC|**G6BK-1114P-FD-US**|5, 6, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6BK-1114C-US**|5, 6, 12, 24 VDC|**G6BK-1114C-FD-US**|24 VDC|| ||Single-side<br>stable|SPST-NO (1a)<br>(Built-in high-<br>capacity operation<br>indicator & diode)|Straight PCB|**G6B-1177P-ND-US**|5, 12, 24 VDC|**G6B-1177P-FD-ND-US**|5, 12, 24 VDC|| ||||<br>Self-clinching<br>PCB|**G6B-1177C-ND-US**|5, 12, 24 VDC|**G6B-1177C-FD-ND-US**|12, 24 VDC|| |2-pole|Single-side<br>stable|SPST-NO (1a)+<br>SPST-NC (1b)<br>(Standard)|Straight PCB|**G6B-2114P-US**|5, 6, 12, 24 VDC|**G6B-2114P-FD-US**|5, 6, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6B-2114C-US**|5, 12, 24 VDC|**G6B-2114C-FD-US**|5, 12 VDC|| |||DPST-NO (2a)<br>(Standard)|Straight PCB|**G6B-2214P-US**|5, 6, 12, 24 VDC|**G6B-2214P-FD-US**|5, 6, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6B-2214C-US**|5, 12, 24 VDC|**G6B-2214C-FD-US**|5, 12, 24 VDC|| |||DPST-NC (2b)<br>(Standard)|Straight PCB|**G6B-2014P-US**|5, 6, 12, 24 VDC|**G6B-2014P-FD-US**|5, 6, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6B-2014C-US**|5, 6, 12, 24 VDC|**G6B-2014C-FD-US**|12, 24 VDC|| Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened. ## ● **Models for Reverse Coil Polarity** |Number<br>of poles||Contact material|Contact material|Standard (Ag-alloy (Cd free))|Standard (Ag-alloy (Cd free))|AgSnIn contact|AgSnIn contact|Minimum<br>packing unit| |---|---|---|---|---|---|---|---|---| ||Relay Function|Contact form|Terminals|Model|Rated coil voltage|Model|Rated coil voltage|| |1-pole|Single-side<br>stable|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6B-1114P-1-US**|5, 6, 12, 24 VDC|**G6B-1114P-FD-1-US**|24 VDC|100<br>pcs/tray| ||||Self-clinching<br>PCB|---|---|---|---|| |||SPST-NO (1a)<br>(High-capacity)|Straight PCB|**G6B-1174P-1-US**|5, 12, 24 VDC|---|---|20<br>pcs/tube| ||||Self-clinching<br>PCB|---|---|---|---|| ||Single-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BU-1114P-1-US**|5, 12 VDC|---|---|100<br>pcs/tray| ||||Self-clinching<br>PCB|---|---|---|---|| ||Double-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BK-1114P-1-US**|5, 6, 12, 24 VDC|---|---|| ||||Self-clinching<br>PCB|---|---|---|---|| |2-pole|Single-side<br>stable|SPST-NO (1a)+<br>SPST-NC (1b)<br>(Standard)|Straight PCB|**G6B-2114P-1-US**|5, 6, 12, 24 VDC|**G6B-2114P-FD-1-US**|12, 24 VDC|| ||||Self-clinching<br>PCB|---|---|---|---|| |||DPST-NO (2a)<br>(Standard)|Straight PCB|**G6B-2214P-1-US**|5, 12, 24 VDC|---|---|| ||||Self-clinching<br>PCB|---|---|---|---|| Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened. **2** G6B **PCB Power Relay** G 6 B ## ● **Models for Ultrasonically Cleanable** |Number<br>of poles||Contact material|Contact material|Standard (Ag-alloy (Cd free))|Standard (Ag-alloy (Cd free))|AgSnIn contact|AgSnIn contact|Minimum<br>packing unit| |---|---|---|---|---|---|---|---|---| ||Relay Function|Contact form|Terminals|Model|Rated coil voltage|Model|Rated coil voltage|| |1-pole|Single-side<br>stable|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6B-1114P-US-U**|5, 6, 12, 24 VDC|**G6B-1114P-FD-US-U**|6, 12, 24 VDC|100<br>pcs/tray| ||||Self-clinching<br>PCB|**G6B-1114C-US-U**|5, 12, 24 VDC|---|---|| ||Single-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BU-1114P-US-U**|24 VDC|---|---|| ||||Self-clinching<br>PCB|---|---|---|---|| ||Double-winding<br>latching|SPST-NO (1a)<br>(Standard)|Straight PCB|**G6BK-1114P-US-U**|5, 6, 12, 24 VDC|**G6BK-1114P-FD-US-U**|12, 24 VDC|| ||||Self-clinching<br>PCB|**G6BK-1114C-US-U**|24 VDC|---|---|| |2-pole|Single-side<br>stable|SPST-NO (1a)+<br>SPST-NC (1b)<br>(Standard)|Straight PCB|**G6B-2114P-US-U**|5, 12, 24 VDC|**G6B-2114P-FD-US-U**|5, 12, 24 VDC|| ||||Self-clinching<br>PCB|---|---|---|---|| |||DPST-NO (2a)<br>(Standard)|Straight PCB|**G6B-2214P-US-U**|5, 6, 12, 24 VDC|**G6B-2214P-FD-US-U**|5, 12, 24 VDC|| ||||Self-clinching<br>PCB|**G6B-2214C-US-U**|12, 24 VDC|---|---|| |||DPST-NC (2b)<br>(Standard)|Straight PCB|**G6B-2014P-US-U**|5, 12, 24 VDC|**G6B-2014P-FD-US-U**|5, 12, 24 VDC|| ||||Self-clinching<br>PCB|---|---|---|---|| Note: When ordering, add the rated coil voltage to the model number. Example: G6B-1114P-US DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ## ● **Connecting Sockets (Sold Separately)** |Applicable relay|Model|Minimum ordering unit| |---|---|---| |G6B-1114P(-FD)-US-P6B<br>G6B-1174P(-FD)-US-P6B<br>G6B-1177P(-FD)-ND-US-P6B<br>G6BU-1114P-US-P6B|**P6B-04P**|20 pcs| |G6BK-1114P-US-P6B|**P6B-06P**|| |G6B-2114P-US-P6B<br>G6B-2214P-US-P6B<br>G6B-2014P-US-P6B|**P6B-26P**|| |Removal Tool|**P6B-Y1**|1 pcs| |Hold-down Clips|**P6B-C2**|| - Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However, when used with the P6B-04P socket models, the allowable current is derated to 5 A. - 2.The P6B sockets are designed to be used with G6B- @@@@ P(-FD)-US-P6B relays. Only use G6B relays that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B" from their model numbers with the sockets. - 3.The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models since they have different heights. - 4.Products with UL/CSA certification marks will be supplied for orders of standard models. **3** G6B **PCB Power Relay** G 6 B ## ■ **Ratings** - **Coil: 1-Pole, Single-side Stable Type** (Including models for ultrasonically cleanable) |Item<br>Rated voltage|Rated current<br>(mA)|Coil resistance<br>(Ω)|<br>Must operate<br>voltage (V)|Must release<br>voltage (V)|Max. voltage<br>(V)|Power consumption<br>(mW)| |---|---|---|---|---|---|---| ||||% of rated voltage|||| |5 VDC|40|125|70% max.|10% min.|160%<br>(at 23°C)|Approx. 200| |6 VDC|33.3|180||||| |12 VDC|16.7|720||||| |24 VDC|8.3|2,880||||| - **Coil: 2-Pole, Single-side Stable Type** (Including models for ultrasonically cleanable) |Item<br>Rated voltage|Rated current<br>(mA)|Coil resistance<br>(Ω)|<br>Must operate<br>voltage (V)|Must release<br>voltage (V)|Max. voltage<br>(V)|Power consumption<br>(mW)| |---|---|---|---|---|---|---| ||||% of rated voltage|||| |5 VDC|60|83.3|80% max.|10% min.|140%<br>(at 23°C)|Approx. 300| |6 VDC|50|120||||| |12 VDC|25|480||||| |24 VDC|12.5|1,920||||| - **Coil: Single-winding Latching Type** (Including models for ultrasonically cleanable) |Item<br>Rated voltage|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must set<br>voltage (V)|Must reset<br>voltage (V)|Max. voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---| ||||% of rated voltage|||Set coil<br>(mW)|Reset coil<br>(mW)| |5 VDC|40|125|70% max.|70% max.|160%<br>(at 23°C)|200|200| |6 VDC|33.3|180|||||| |12 VDC|16.7|720|||||| |24 VDC|8.3|2,880|||||| - **Coil: Double-winding Latching Type** (Including models for ultrasonically cleanable) |Item<br>Rated voltage|Rated current (mA)|Rated current (mA)|Coil resistance (Ω)|Coil resistance (Ω)|Must set voltage<br>(V)|Must reset voltage<br>(V)|Max. voltage<br>(V)|Power consumption|Power consumption| |---|---|---|---|---|---|---|---|---|---| ||Set coil|Reset coil|Set coil|Reset coil|% of rated voltage|||Set coil<br>(mW)|Reset coil<br>(mW)| |5 VDC|56|56|89.2|89.2|70% max.|70% max.|130%<br>(at 23°C)|280|280| |6 VDC|46.8|46.8|128.5|128.5|||||| |12 VDC|23.3|23.3|515|515|||||| |24 VDC|11.7|11.7|2,060|2,060|||||| - **Coil: Operation Indicator Model** (Flux-resistant type. Do not wash down with water.) |Item<br>Rated voltage|Rated current<br>(mA)|Coil resistance<br>(Ω)|<br>Must operate<br>voltage (V)|Must release<br>voltage (V)|Max. voltage<br>(V)|Power consumption<br>(mW)| |---|---|---|---|---|---|---| ||||% of rated voltage|||| |5 VDC|43|116|70% max.|10% min.|130%<br>(at 23°C)|Approx. 200| |12 VDC|19.7|610||||Approx. 240| |24 VDC|11.3|2,120||||Approx. 275| - Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.The operating characteristics are measured at a coil temperature of 23°C. - 3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ## ● **Contacts** |Model|G6B-1114P(-FD)(-1)-US<br>G6BU-1114P(-FD)(-1)-US<br>G6BK-1114P(-FD)(-1)-US<br>G6B-1114C(-FD)-US<br>G6BU-1114C-US<br>G6BK-1114C(-FD)-US|G6B-1114P(-FD)(-1)-US<br>G6BU-1114P(-FD)(-1)-US<br>G6BK-1114P(-FD)(-1)-US<br>G6B-1114C(-FD)-US<br>G6BU-1114C-US<br>G6BK-1114C(-FD)-US|G6B-1174P(-FD)(-1)-US<br>G6B-1177P(-FD)-ND-US<br>G6B-1174C(-FD)-US<br>G6B-1177C(-FD)-ND-US|G6B-1174P(-FD)(-1)-US<br>G6B-1177P(-FD)-ND-US<br>G6B-1174C(-FD)-US<br>G6B-1177C(-FD)-ND-US|G6B-1184P-US|G6B-1184P-US|G6B-2114P(-FD)(-1)-US<br>G6B-2214P(-FD)(-1)-US<br>G6B-2014P(-FD)-US<br>G6B-2114C(-FD)-US<br>G6B-2214C(-FD)-US<br>G6B-2014C(-FD)-US|G6B-2114P(-FD)(-1)-US<br>G6B-2214P(-FD)(-1)-US<br>G6B-2014P(-FD)-US<br>G6B-2114C(-FD)-US<br>G6B-2214C(-FD)-US<br>G6B-2014C(-FD)-US| |---|---|---|---|---|---|---|---|---| |Load<br>Item|Resistive load<br>|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)|<br>Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)|<br>Resistive load<br>|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)|<br>Resistive load|Inductive load<br>(cosφ= 0.4; L/R = 7 ms)| |Contact type|Single||||Single crossbar||Single|| |Contact material|Ag-Alloy (Cd free)||||Au-alloy + Ag (Cd free)||Ag-Alloy (Cd free)|| |Rated load|5 A (3 A) at 250 VAC<br>5 A (3 A) at 30 VDC|2 A (2 A) at 250 VAC<br>2 A (2 A) at 30 VDC|8 A (5 A) at 250 VAC<br>8 A (5 A) at 30 VDC|2 A (2 A) at 250 VAC<br>2 A (2 A) at 30 VDC|2 A at 250 VAC<br>2 A at 30 VDC|0.5 A at 250 VAC<br>0.5 A at 30 VDC|5 A (3 A) at 250 VAC<br>5 A (3 A) at 30 VDC|1.5 A (1.5 A) at 250 VAC<br>1.5 A (1.5 A) at 30 VDC| |Rated carry current|5 A (5 A)||8 A (5 A)||2A||5 A (5 A)|| |Max. switching voltage|380 VAC, 125 VDC|||||||| |Max. switching current|5 A (5 A)||8 A (5 A)||2A||5 A (5 A)|| Note 1. The values in the parentheses ( ) are for -FD models only. - 2.Use the -FD type for inductive load and switching load which contact roughening is small. **4** G6B **PCB Power Relay** G 6 B ## ■ **Characteristics** |Model|Model|G6B-1114P(-FD)(-1)-US<br>G6B-1174P(-FD)(-1)-US<br>G6B-1114C(-FD)-US<br>G6B-1174C(-FD)-US|G6BU-1114P(-FD)(-1)-US<br>G6BU-1114C-US|G6BK-1114P(-FD)(-1)-US<br>G6BK-1114C(-FD)-US|G6B-1177P(-FD)-ND-US<br>G6B-1177C(-FD)-ND-US|G6B-1184P-US|G6B-2114P(-FD)(-1)-US<br>G6B-2214P(-FD)(-1)-US<br>G6B-2014P(-FD)(-1)-US<br>G6B-2114C(-FD)-US<br>G6B-2214C(-FD)-US<br>G6B-2014C(-FD)-US| |---|---|---|---|---|---|---|---| |Item<br>Classification||Single-side stable|Single-winding<br>latching|Double-winding<br>latching|Built-in operation indicator<br>& surge absorption diode|<br>Single-side stable|Single-side stable| |Contact resistance *1||30 mΩmax.||||50 mΩmax.|30 mΩmax.| |Operate(set)time||10 ms max.|||||| |Release(reset)time||10 ms max.|||||| |Min. setpulse width||−|15 ms(at 23°C)||−||| |Min. resetpulse width||−|15 ms(at 23°C)||−||| |Insulation resistance *2||1,000 MΩmin.|||||| |Dielectric<br>strength|Between coil and<br>contacts|3,000 VAC, 50/60 Hz for 1 min||2,000 VAC,<br>50/60 Hz for 1 min|3,000 VAC, 50/60 Hz for 1 min||| ||Between contacts<br>of the samepolarity|1,000 VAC, 50/60 Hz for 1 min|||||| ||Between contacts<br>of differentpolarity|−|||||2,000 VAC,<br>50/60 Hz for 1 min| ||Between set and<br>reset coils|−||250 VAC,<br>50/60 Hz for 1 min|−||| |Impulse withstand voltage<br>(between coil and contacts)||6 kV 1.2×50μs|4.5 kV 1.2×50μs||6 kV 1.2×50μs|−|6 kV 1.2×50μs| |Vibration<br>resistance|Destruction|10 to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)|||||| ||Malfunction|10 to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)|||||| |Shock<br>resistance|Destruction|1,000 m/s2|||||| ||Malfunction|100 m/s2|300 m/s2||100 m/s2||| |Durability|Mechanical|50,000,000 operations min.(at 18,000 operations/hr)|||||| ||Electrical|100,000 operation min.(at 1,800 operations/hr under rated load)|||||| |Failure rate<br>(reference|(P level)<br>value)*3|10 mA at 5 VDC||||1 mA at 1 VDC|10 mA at 5 VDC| |Ambient operatingtemperature||-25°C to 70°C(with no icingor condensation)|||||| |Ambient operatinghumidity||5% to 85%|||||| |Weight||Approx. 3.5 to 4.6g|Approx. 3.5g|Approx. 3.7g|Approx. 5.4g|Approx. 3.5g|Approx. 4.5g| - Note 1. The values here are initial values. - 2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water. *1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.(Except the location between set/reset coil) - *3. This value was measured at a switching frequency of 120 operations/min. **5** G6B **PCB Power Relay** ## ■ **Engineering Data** **==> picture [547 x 392] intentionally omitted <==** **----- Start of picture text -----**<br> ● Maximum Switching Current G6B-2114P-US<br>G6B-1114P-US G6B-1174P-US G6B-2214P-US<br>G6B-1174P-FD-US G6B-2014P-US<br>40 100 100<br>20 50 50<br>30 30<br>10 AC resistive load G6B-2114P-FD-USG6B-2214P-FD-US AC inductive load<br>AC resistive load G6B-2014P-FD-US (cosφ = 0.4)<br>5 108 10 AC resistive<br>3 AC 5 5 load<br>21 DC inductive load (L/R = 7 ms) inductive loadcosφ = 0.4 32 DC resistive load AC 1.532<br>1 inductive 1 AC<br>0.5 DC resistive load 0.5 load 0.5 DC resistive load resistive load<br>0.3 DC inductive load<br>0.3 0.3<br>0.2 DC inductive load<br>(L/R = 7 ms)<br>0.1 0.1 0.1<br>0 3 5 10 20 30 100 300 500 0 3 5 10 30 50 100 380 1,000 0 3 5 10 30 50 100 300 500 1,000<br>Switching voltage (V) Switching voltage (V) Switching voltage (V)<br>● Ambient Temperature vs.<br>● Durability Maximum Coil Voltage<br>G6B-1114P-US G6B-2114P(-FD)-US G6B-1114P-US G6B-2114P-US<br>G6B-1174P-US G6B-2214P(-FD)-US G6B-1174P-US G6B-2214P-US<br>G6B-1174P-FD-US G6B-2014P(-FD)-US G6B-1174P-FD-US G6B-2014P-US<br>G 1,000 1,000 200<br>B6 500300 G6B-1114P-US250 VAC/30 VDC resistive load 500300 G6B-2114PG6B-2214P(-FD)-USG6B-2014P(-FD)-US(-FD)-US 180 G6B-1114P-US<br>G6B-1174P-FD-US 250 VAC/30 VDC resistive load 250 VAC/30 VDC inductive load(cosφ = 0.4, L/R = 7 ms) 160 G6B-1174P-USG6B-1174P-FD-US<br>100 100<br>G6B-1174P-US G6B-2114P-US<br>50 250 VAC/30 VDC 50 G6B-2214P-US 140<br>resistive load G6B-2014P-US<br>30 30 250 VAC/30 VDC resistive load 130<br>120<br>110<br>10 10<br>Higher 100 G6B-2114P-US<br>5 G6B-1114P-US capacity 5 G6B-2114P-FD-US G6B-2214P-US<br>G6B-1174P-FD-US G6B-2214P-FD-US G6B-2014P-US<br>3 G6B-1174P-US 3 G6B-2014P-FD-US 80<br>250 VAC/30 VDC inductive load 250 VAC resistive load<br>(cosφ = 0.4, L/R = 7 ms)<br>1 1 60<br>0 1 2 3 4 5 6 7 8 9 10 0 1 1.5 2 3 4 5 6 7 8 9 10 0 20 23 30 40 50 60 70 80 90<br>Switching current (A) Switching current (A) Ambient temperature (°C)<br>Switching current (A) Switching current (A) Switching current (A)<br>4 operations) 4 operations)<br>Maximum coil voltage (%)<br>Durability (x10 Durability (x10<br>**----- End of picture text -----**<br> Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage. **==> picture [511 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> ● Ambient Temperature vs. Must ● Mutual Magnetic Interference<br>Operate and Must Release Voltage<br>G6B-1114P-US G6B-1114P-US G6B-1114P-US<br>100 Must operate voltage Must operate voltage<br>Sample: Must operate voltage Must release voltage Must release voltage<br>80 G6B-1114P-USNumber of Relays: 5 pcs Must release voltagemax. 2.54 mm +1.0 Initial stage Test +1.0 Initial stage Test<br>X +0.5 +0.5<br>min.<br>0 2.54 mm 0<br>60 Sample<br>−0.5 −0.5<br>De-energized −1.0 Average value Sample −1.0 Average value<br>40 max. De-energized<br>X Sample +1.0 Initial stage Test +1.0 Initial stage Test<br>min.<br>+0.5 +0.5<br>20<br>Sample<br>0 0<br>0 Energized −0.5 −0.5<br>−40 −20 0 20 40 60 80<br>−1.0 Average value Energized −1.0 Average value<br>Ambient temperature (°C)<br>Change rate on the basis of initial value (%) Change rate on the basis of initial value (%)<br>Must-operate/must-release voltage (%)<br>Change rate on the basis of initial value (%) Change rate on the basis of initial value (%)<br>**----- End of picture text -----**<br> **6** **PCB Power Relay** G 6 B ## G6B ## ● **Shock Malfunction** **==> picture [303 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> Y Y<br>1,000<br>Energized Energized<br>300<br>X Z X Z<br>400 1,000 1,000<br>300<br>100 600<br>200<br>200<br>100<br>300 400 1,000 1,000<br>Z' X' Z' X'<br>300<br>Unit: m/s [2] 1,000 Unit: m/s [2]<br>Y' Y'<br>**----- End of picture text -----**<br> **==> picture [125 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> Y<br>1,000 Reset<br>Set<br>X Z<br>1,000 1,000<br>700<br>1,000 1,000<br>Z' X'<br>1,000 Unit: m/s [2]<br>Y'<br>**----- End of picture text -----**<br> Sample: G6B-1174P-US G6B-1174P-FD-US Sample: G6B-1114P-US Number of Relays: 12 pcs **==> picture [148 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> Sample: G6BK-1114P-US<br>Number of Relays: 12 pcs<br>Test Conditions: The value at which<br>malfunction occurred was measured after<br>applying shock to the Shock direction<br>test piece 3 times each X X'<br>in 6 directions along 3 Y<br>Z<br>axes.<br>Standard value: Z'<br>300 m/s [2] Y' (Coil)<br>40 Sample: G6B-2114P-US<br> G6B-2214P-US<br> G6B-2014P-US<br>30 Test: the variation of operating voltage is<br>measured based on coil cold start at 23°C, during<br>which rated voltage is applied to the coil with rated<br>20 contact current (5A), and left<br>for 1 hour each under different<br>ambient temperatures.<br>10<br>120% applied<br>0 110% applied<br>100% applied<br>−10<br>−20<br>−50 −40 −20 0 20 40 60 80 100<br>Ambient temperature (°C)<br>Rate of variability (%)<br>**----- End of picture text -----**<br> **==> picture [142 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> Test Conditions: Shock is applied in ±X, ±Y,<br>and ±Z directions three times each with without<br>energizing the Relays Shock direction<br>to check the number of X X'<br>Y<br>malfunctions.<br>Requirement: None malfuction 100 m/smalfuction 100 m/s [[2]] ZZ'Z'<br>Y' (Coil)<br>**----- End of picture text -----**<br> **==> picture [326 x 235] intentionally omitted <==** **----- Start of picture text -----**<br> Test Conditions: Shock is applied in ±X, ±Y, Test Conditions: Shock is applied in ±X, ±Y,<br>and ±Z directions three times each with without and ±Z directions three times each with without<br>energizing the Relays Shock direction energizing the Relays Shock direction<br>to check the number of X X' to check the number of X X'<br>malfunctions. Y malfunctions. Y<br>Requirement: None ZZ' ZZ'Z'<br>malfuction 100 m/s [2] Requirement: None malfuction 100 m/smalfuction 100 m/s [[2]]<br>Y' (Coil) Y' (Coil)<br>Hot Start<br>40 Sample: G6B-1114P-US 40 Sample: G6B-1174P-US<br>30 G6B-1174P-FD-US Number of Relays: 10 pcsTest: the variation of operating voltage is measured 30 Test: the variation of operating voltage is measured based on cold start at 23voltage is applied to the coil with rated contact °C, during which rated<br>based on cold start at 23°C, during which rated current (8A), and left for 1 hour<br>voltage is applied to the coil with rated each under different ambient<br>20 contact current (5A), and left for 1 20 temperatures.<br>hour each under different<br>ambient<br>10 temperatures. 120% applied 10 120% applied<br>110% applied<br>110% applied 100% applied<br>0 100% applied 0<br>−10 −10<br>−20 −20<br>−50 −40 −20 0 20 40 60 80 100 −50 −40 −20 0 20 40 60 80 100<br>Ambient temperature (°C) Ambient temperature (°C)<br>Rate of variability (%) Rate of variability (%)<br>**----- End of picture text -----**<br> ## ● **Hot Start** ## ■ **Dimensions** **(Unit: mm)** **==> picture [344 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> 1-pole Single-side Stable Models (SPST-NO(1a))<br>Straight PCB 10 max.<br>G6B-1114P(-FD)(-1)-US (9.8)*<br>G6B-1184P-US 10 max.<br>(9.8)* 0.3<br>3.5<br>0.85 0.9<br><0.9> <1.0><br>0.9<1.0> 0.5<0.4><br>20 max.<br>0.5 (19.9)*<br>2.54<br>* Average value<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket. 2.54<br>Self-clinching PCB<br>G6B-1114C(-FD)-US<br>10 max.0 max.x.<br>**----- End of picture text -----**<br> **PCB Mounting Holes Terminal Arrangement/** (BOTTOM VIEW) **Internal Connections** Tolerance: ±0.1 mm (BOTTOM VIEW) **==> picture [190 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> Four, 1.1-dia. holes<br>(1.2) 1<br>3 4<br>6<br>Note: Check carefully the coil<br>1 0.16 7 .62 polarity of the Relay. Polarity in<br>(1.1) the parenthesis is the models for<br>reverse coil polarity.<br>**----- End of picture text -----**<br> **==> picture [174 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> 10 max.0 max.x.<br>(9.8)*<br>10 max.<br>(9.8)* 0.3 (1.0)<br>3.2 3.5<br>0.85 0.9 (0.8)<br>0.9 0.5<br>20 max.<br>0.5 (19.9)*<br>* Average value<br>**----- End of picture text -----**<br> Note: Orientation marks are indicated as follows: **7** G6B **PCB Power Relay** ## **1-pole Single-side Stable Models (SPST-NO(1a)) Straight PCB G6B-1174P(-FD)(-1)-US** **==> picture [516 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> Straight PCB 10 max.<br>G6B-1174P(-FD)(-1)-US (9.9)*<br>12.5 max.<br>(12.45)* 0.65<br>PCB Mounting Holes Terminal Arrangement/<br>3.5 (BOTTOM VIEW) Internal Connections<br><0.9>0.85 <1.0>0.9 Tolerance: ±0.1 mm (BOTTOM VIEW)<br>0.9<1.0> 0.5<0.4><br>20.2 max .<br>2.54<br>0.45 (20.0)* Four, 1.1-dia. holes<br>* Average value<br>Dimensions in pointed brackets < > are for the 2.54<br>Relay mounted to Socket. (1.2) 1<br>3 4<br>Self-clinching PCB 6<br>G6B-1174C(-FD)-US Note: Check carefully the coil<br>10 max.(9.9)* 1 0.16 7 .62 polarity of the Relay. Polarity in<br>(1.2) the parenthesis is the models for<br>12.5 max. reverse coil polarity.<br>(12.45)* 0.65 (1.0) Note: Orientation marks are indicated as follows:<br>3.2 3.5<br>0.85 0.9 (0.8)<br>0.9 0.5<br>20.2 max.<br>0.45 (20.0)*<br>* Average value<br>**----- End of picture text -----**<br> ## **1-pole Single-winding Latching Model (SPST-NO(1a))** G **Straight PCB** 6 **G6BU-1114P(-1)-US** B **==> picture [298 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> Straight PCB 10 max.<br>G6BU-1114P(-1)-US (9.8)*<br>10 max.<br>(9.8)* 0.3<br>3.5<br>0.85 0.9<br><0.9> <1.0><br>0.9<1.0> 0.5<0.4><br>20 max.<br>0.5 (19.9)* * Average value<br>Dimensions in pointed brackets < > are for the<br>Relay mounted to Socket.<br>Self-clinching PCB<br>G6BU-1114C-US<br>10 max.<br>(9.8)*<br>10 max.<br>(9.8)* 0.3 (1.0)<br>3.5 3.2<br>0.85 0.9 (0.8)<br>0.9 0.5<br>20 max.<br>0.5 (19.9)* * Average value<br>**----- End of picture text -----**<br> **PCB Mounting Holes Terminal Arrangement/** (BOTTOM VIEW) **Internal Connections** Tolerance: ±0.1 mm (BOTTOM VIEW) **==> picture [211 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> 2.54<br>Four, 1.1-dia. holes<br>2.54<br>(1.2) 1<br>3 4<br>S R<br>6<br>Note: Check carefully the coil<br>polarity of the Relay. Polarity in<br>1 0.16 7 .62 the parenthesis is the models<br>(1.1) for reverse coil polarity.<br>S: Set coil<br>R: Reset coil<br>**----- End of picture text -----**<br> Note: Orientation marks are indicated as follows: ## **1-pole Double-winding Latching Model (SPST-NO(1a)) Straight PCB G6BK-1114P(-FD)(-1)-US** **==> picture [512 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> 10 max.<br>G6BK-1114P(-FD)(-1)-US (9.8)*<br>10 max.(9.8)* 0.3 PCB Mounting Holes Terminal Arrangement/<br>(BOTTOM VIEW) Internal Connections<br>3.5 Tolerance: ±0.1 mm (BOTTOM VIEW)<br>0.85 0.9<br><0.9>0.85 <0.9> <1.0> 0.9<1.0> 0.5<0.4><br>20 max. 2.54 Six, 1.1-dia. holes<br>0.5 (19.9)* * Average value<br>2.54<br>Dimensions in pointed brackets < > are for the (1.2) 1 2<br>Relay mounted to Socket. S R [3] 4<br>6 5<br>Self-clinching PCB<br>Note: Check carefully the coil<br>G6BK-1114C(-FD)-US 10 max. polarity of the Relay. Polarity in<br>(9.8)* 2.54 7 .62 7 .62 the parenthesis is the models<br>(1.1) for reverse coil polarity.<br>10 max. S: Set coil<br>(9.8)* 0.3 (1.0) R: Reset coil<br>3.5 3.2 Note: Orientation marks are indicated as follows:<br>0.85 0.85 0.9 (0.8)<br>0.9 0.5<br>20 max.<br>0.5 (19.9)* * Average value<br>**----- End of picture text -----**<br> **8** G6B **PCB Power Relay** G 6 B **==> picture [514 x 732] intentionally omitted <==** **----- Start of picture text -----**<br> 1-pole Single-side stable Models (SPST-NO (1a)) (Built-in high capacity operation indicator & surge absorption diode)<br>Straight PCB<br>G6B-1177P(-FD)-ND-US 0.45 20.2 max(20)* .<br>3.7<br>1.7<br>10 max.<br>(9.9)*<br>LED<br>1.6<br>0.3<br>15 max.<br>(14.8)*<br>0.65 PCB Mounting Holes Terminal Arrangement/<br>(BOTTOM VIEW) Internal Connections<br>3.5 Tolerance: ±0.1 mm (BOTTOM VIEW)<br>0.85 0.9<br><0.9> <1.0><br>0.9<1.0> 0.5<0.4> 2.54 Four, 1.1-dia. holes<br>10.16 7.62 7.62<br>* Average value<br>Dimensions in pointed brackets < > are for the 2.54 1 3 4<br>Relay mounted to Socket. 7.62<br>6<br>Self-clinching PCB (1.2) Note: Check carefully the<br>G6B-1177C(-FD)-ND-US 0.45 20.2 max. (1.11) 10.16 7 .62 coil polarity of the Relay.<br>(20)*<br>3.7<br>Note: The G6B-1177P-ND-US model has a flux-resistant<br>1.7 construction. Do not wash it down with water. Pay<br>10 max. attention to the polarity of the coil since the LED and<br>(9.9)* surge absorption diode are built-in.<br>LED<br>1.6<br>0.3<br>15 max.<br>(14.8)*<br>0.65 (1.0)<br>3.5 3.2<br>0.85 0.9 (0.8)<br>0.9 0.5<br>1 0.16 7 .62 7.62<br>* Average value<br>2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b), DPST-NO (2a), DPST-NC(2b))<br>Straight PCB 20 max.<br>G6B-2114P(-FD)(-1)-US (19.9)*<br>G6B-2214P(-FD)(-1)-US 11 max.<br>G6B-2014P(-FD)-US (10.9)*<br>PCB Mounting Holes Terminal Arrangement/<br>(BOTTOM VIEW) Internal Connections<br>Tolerance: ±0.1 mm (BOTTOM VIEW)<br>11 max.<br>(10.9)*<br>2.54 Six, 1.1-dia. holes<br>3.5 G6B-2114<br>0.9<0.8> 0.4<0.3> 2.54 1 3 4<br>1 0.16 7 .62 7.62 7.62<br>* Average value<br>Dimensions in pointed brackets < > are for the 8 6 5<br>Relay mounted to Socket. (1.7)<br>(1.11) 1 0.16 7 .62 G6B-2014<br>Self-clinching PCB 1 3 4<br>G6B-2114C(-FD)-US 20 max.<br>G6B-2214C(-FD)-US (19.9)* 8 6 5<br>G6B-2014C(-FD)-US<br>11 max. G6B-2214<br>(10.9)*<br>1 3 4<br>8 6 5<br>11 max. Note: Check carefully the coil<br>(10.9)* (1.0) polarity of the Relay. Polarity in<br>the parenthesis is the models<br>3.5 3.2 for reverse coil polarity.<br>(0.8)<br>0.8 0.3<br>1 0.16 7 .62 7.62<br>* Average value<br>**----- End of picture text -----**<br> **9** G6B **PCB Power Relay** ## ■ **Connecting Sockets Dimensions** **Socket for 1-pole Single-winding Latching Model and Single-side Stable Model P6B-04P** 23.2 max. **==> picture [172 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 23.2 max.<br>(23)*<br>10 max.<br>(9.9)* 3.1<br>10.1 max.<br>(10)* 7<br>3.5<br>0.8 0.4<br>1 0.16 7.62 7.62<br>* Average value<br>**----- End of picture text -----**<br> **==> picture [150 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Mounting Holes<br>(BOTTOM VIEW)<br>Tolerance: ±0.1 mm<br>2.54 Four, 1.1-dia. holes<br>2.54<br>(1.2)<br>(2.71) 1 0.16 7 .62<br>**----- End of picture text -----**<br> **Socket for 1-pole Double-winding Latching Model P6B-06P** 23.2 max. **==> picture [545 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> P6B-06P 23.2 max. PCB Mounting Holes<br>(23)* (BOTTOM VIEW)<br>Tolerance: ±0.1 mm<br>10 max.<br>(9.9)* 3.1 2.54 Six, 1.1-dia. holes<br>G 2.54<br>6 10.1 max. (1.2)<br>B (10)* 7<br>3.5<br>(2.71) 7 .62 7 .62<br>0.8 0.4 2.54<br>2.54 7.62 7.62 7.62<br>* Average value<br>Socket for Double-pole Single-side Stable<br>P6B-26P<br>**----- End of picture text -----**<br> **==> picture [147 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Mounting Holes<br>(BOTTOM VIEW)<br>Tolerance: ±0.1 mm<br>2.54 Six, 1.1-dia. holes<br>2.54<br>(1.6)<br>(2.61) 1 0.16 7 .62<br>**----- End of picture text -----**<br> **==> picture [172 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 23.2 max.<br>(23)*<br>11 max.<br>(10.8)* 3.1<br>10.1 max.<br>(10)* 7<br>3.5<br>0.8 0.4<br>1 0.16 7.62 7.62<br>* Average value<br>**----- End of picture text -----**<br> ## ■ **Removal Tool** ## **P6B-Y1** ## ■ **Hold-down Clips** **P6B-C2** ## ■ **Related Products** The G6B-4 Terminal Relay series with 4-point output is also available. For details, contact your OMRON sales representative. **10** G6B **PCB Power Relay** G 6 B ## ■ **Approved Standards** - The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. **UL Recognized:** ## (File No. E41643) |Model|Contact<br>form|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6B-1114P(-FD)(-1)-US<br>G6B-1114C(-FD)-US|1|3 to 24<br>VDC|5 A, 250 VAC (General Use) 80°C|6,000| ||||5 A, 30 VDC (Resistive) 80°C|| ||||1/8HP, 250 VAC 80°C|1,000| ||||1/6HP, 250 VAC 80°C|| |G6B-1174P(-FD)(-1)-US<br>G6B-1174C(-FD)-US|1|3 to 24<br>VDC|8 A, 277 VAC (General Use) 80°C|30,000| ||||8 A, 30 VDC (Resistive) 80°C|6,000| |G6B-1184P-US|1|3 to 24<br>VDC|2 A, 250 VAC (General Use) 80°C|| ||||2 A, 30 VDC (Resistive) 80°C|| |G6B-2114P(-FD)(-1)-US<br>G6B-2214P(-FD)(-1)-US<br>G6B-2014P(-FD)-US<br>G6B-2114C(-FD)-US<br>G6B-2214C(-FD)-US<br>G6B-2014C(-FD)-US|2|3 to 24<br>VDC|5 A, 250 VAC (General Use) 80°C|| ||||5 A, 30 VDC (Resistive) 80°C|| ## **CSA Certified:** (File No. LR31928) |Model|Contact<br>form|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6B-1114P(-FD)(-1)-US<br>G6B-1114C(-FD)-US|1|3 to 24<br>VDC|5 A, 250 VAC (General Use) 80°C|6,000| ||||5 A, 30 VDC (Resistive) 80°C|| ||||1/6HP, 250 VAC 80°C|1,000| ||||360 W, 120 VAC tungsten 80°C|6,000| |G6B-1174P(-FD)(-1)-US<br>G6B-1174C(-FD)-US|1|3 to 24<br>VDC|8 A, 277 VAC (General Use) 80°C|30,000| ||||8 A, 30 VDC (Resistive) 80°C|6,000| |G6B-2114P(-FD)(-1)-US<br>G6B-2214P(-FD)(-1)-US<br>G6B-2014P(-FD)-US<br>G6B-2114C(-FD)-US<br>G6B-2214C(-FD)-US<br>G6B-2014C(-FD)-US|2|3 to 24<br>VDC|5 A, 250 VAC (General Use) 80°C|| ||||5 A, 30 VDC (Resistive) 80°C|| ## **EN/IEC, TÜV Certified:** (Registration No. R50158246) |Model|Contact<br>form|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6B-1114P(-1)-US<br>G6B-1114C-US|1|5, 6, 12, 24<br>VDC|5 A, 250 VAC (cosφ= 1) at 70°C|20,000| ||||2 A, 250 VAC(cosφ= 0.4) at 70°C|| ||||5 A, 30 VDC (L/R = 0 ms) at 70°C|| |G6B-1174P(-1)-US<br>G6B-1174C-US|1|5, 6, 12, 24<br>VDC|8 A, 250 VAC (cosφ= 1) at 70°C|| ||||2 A, 250 VAC (cosφ= 0.4) at 70°C|| ||||8 A, 30 VDC (L/R = 0 ms) at 70°C|| |G6B-2114P(-1)-US<br>G6B-2214P(-1)-US<br>G6B-2014P-US<br>G6B-2114C-US<br>G6B-2214C-US<br>G6B-2014C-US|2|5, 6, 12, 24<br>VDC|5 A, 250 VAC (cosφ= 1) at 70°C|| ||||1.5 A, 250 VAC (cosφ= 0.4) at 70°C|| ||||5 A, 30 VDC (L/R = 0 ms) at 70°C|| |G6B-1114P-FD(-1)-US<br>G6B-1114C-FD-US|1|5, 6, 12, 24<br>VDC|3 A, 250 VAC (cosφ= 1) at 70°C|10,000| ||||3 A, 30 VDC (L/R = 0 ms) at 70°C|| |G6B-1174P-FD(-1)-US<br>G6B-1174C-FD-US|1|5, 6, 12, 24<br>VDC|5 A, 250 VAC (cosφ= 1) at 70°C|| ||||2 A, 250 VAC (cosφ= 0.4) at 70°C|| ||||5 A, 30 VDC (L/R = 0 ms) at 70°C|| |G6B-2114P-FD(-1)-US<br>G6B-2214P-FD(-1)-US<br>G6B-2014P-FD-US<br>G6B-2114C-FD-US<br>G6B-2214C-FD-US<br>G6B-2014C-FD-US|2|5, 6, 12, 24<br>VDC|1.5 A, 250 VAC (cosφ= 0.4) at 70°C|| ||||3 A, 30 VDC (L/R = 0 ms) at 70°C|| **11** G6B **PCB Power Relay** ## ■ **Precautions** - **Please refer to “PCB Relays Common Precautions” for correct use.** ## Correct Use ## ● **Mounting** - When installing more than two Relays side by side on a PCB, keep the gaps as shown below. It may cause a malfunction if heat is not dissipated smoothly from the Relay. **==> picture [129 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Pitch:<br>2.54 mm × 2 min.<br>between terminals<br>Pitch: 2.54 mm × 2 min.<br>between terminals<br>**----- End of picture text -----**<br> - No specified mounting direction. - **Mounting Height of Sockets and Precautions** **==> picture [173 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> G * 19.5 mm max. for<br>6 *17 mm max. G6B-1174P-FD-US,<br>B 7 mm max. G6B-1174P-US models and 22 mm max. for<br> G6B-1177P-FD-ND-US,<br> G6B-1177P-ND-US models.<br>• Hold-down clips (for mounting and<br>removal) are also available.(For P6B-<br>C2 model) However, it is not suitable<br>for G6B-1174P and G6B-1177P<br>models.<br>**----- End of picture text -----**<br> - Removal tool is also available. (For P6B-Y1 model) However, it is not suitable for G6B-1177P model. - **Inhibit Circuit of the G6B-1177P(-FD)-ND-US Model** - Do not use under conditions in which a surge is included in the power supply, such as when an inductive load is connected in parallel to the coil. Doing so will cause damage to the installed (or built-in) coil surge absorbing diode. **==> picture [125 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> Inductive load L G6BCoil Coil surge absorption diode<br>**----- End of picture text -----**<br> ## ● **Using SPDT contact of the SPST-NO+SPST-NC Relay** - Do not construct a circuit so that - overcurrent and burning occur if the NO, NC and SPDT contacts are short-circuited with the - SPST-NO+SPST-NC Relay.Arcing may generate short-circuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. ## ● **Other precautions** - The P6B model has a flux-resistant construction. Do not wash it down with water. - Perform wiring of No.1 and No. 2 of the X terminal as COM for doublewinding latching as shown below. The operation stability improves by doing this. **==> picture [50 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> 6 5<br>S R<br>1 2<br>COM<br>**----- End of picture text -----**<br> - Check carefully the coil polarity (+ and -) of the Relay G6B-1177P(-FD)-ND-US. Do not reverse the polarity when connecting. Otherwise the built-in coil surge absorption diode may be damaged. - This Relay is a Power Relay which is suitable for power load switching. Do not use the G6B for signal purposes such as micro load switching under 10 mA. > • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. > • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. **Note: Do not use this document to operate the Unit.** **OMRON Corporation Electronic and Mechanical Components Company** **Contact: www.omron.com/ecb** **Cat. No. K021-E1-16** 0118(0207)(O) **12**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →