G3RV-SL700-A DC24
Solid State Relay, SPST, 2 A, 24 VDC, DIN Rail, Screw
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type:
- SVHC: To Be Advised
- Product Range: G3RV-SL Series
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.45 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Solid State Relays G3RV**
## **Slimmest OMRON plug-in SSR with maximum width 6.2 mm**
- Long electrical life and high speed switching
- Large plug-in terminals for reliable connection
- G3RV-D (DC load) models can manage resistive loads of 100 µA to 3.0 A
- LED indicator for visible operation checking
- Convenient quick electrical connections possible with G3RV push-in models and cross bar connectors
- Low power consumption for energy savings
- G3RV is cUL listed when correct relay is matched with the G3RV Socket
## **Model Number Structure**
## ■ **Model Number Legend**
**G3RV-SL** @ @ @ **-** @ **1 2 3 4**
**1. Basic Model Name** G3RV: Solid State Relay
## **2. Auxiliary Type Designation**
SL: Slim Solid State Relay and socket combination
**4. Output voltage specifications** A(L): AC Output .. TRIAC
- *A: with Zero cross function AL: without Zero cross function
- D: DC Output .. MOS FET
**3. Wire Connection**
- 700: Screw Terminals
- 500: Push-in (screwless) terminals
## **Orderin Information g**
## ■ **List of Models**
|**Classification**|**Classification**|**Enclosure rating**|**Input voltage**|**Type of connection**|**Contact form**|
|---|---|---|---|---|---|
||||||**SPST**|
|Plug-in terminals|General-purpose|Unsealed|AC/DC|Screw terminals|G3RV-SL700|
|||||Push-in terminals|G3RV-SL500|
## **SSR and Socket Combinations**
|**Input voltage**|**Screw terminals**|**Push-in terminals**|
|---|---|---|
|12 VDC|G3RV-SL700-D 12VDC|G3RV-SL500-D 12VDC|
||G3RV-SL700-A(L) 12VDC|G3RV-SL500-A(L) 12VDC|
|24 VDC|G3RV-SL700-D 24VDC|G3RV-SL500-D 24VDC|
||G3RV-SL700-A(L) 24VDC|G3RV-SL500-A(L) 24VDC|
|24 VAC/DC|G3RV-SL700-D 24VAC/DC|G3RV-SL500-D 24VAC/DC|
||G3RV-SL700-A(L) 24VAC/DC|G3RV-SL500-A(L) 24VAC/DC|
|48 VAC/DC|G3RV-SL700-D 48VAC/DC|G3RV-SL500-D 48VAC/DC|
||G3RV-SL700-A(L)48VAC/DC|G3RV-SL500-A(L)48VAC/DC|
|110 VAC|G3RV-SL700-D 110VAC|G3RV-SL500-D 110VAC|
||G3RV-SL700-A(L)110VAC|G3RV-SL500-A(L)110VAC|
|230 VAC|G3RV-SL700-D 230VAC|G3RV-SL500-D 230VAC|
||G3RV-SL700-A(L) 230VAC|G3RV-SL500-A(L) 230VAC|
Solid State Relays **G3RV**
1
**S ecifications p**
## ■ **Ratings (at an Ambient Temperature of 25°C)**
## **Input**
## **G3RV-SL700/500-A Series**
|**Rated voltage**|**Rated current**|**Rated current**|**Rated current**|**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Input voltage**|
|---|---|---|---|---|---|---|
||**AC**||**DC**|||**% of rated voltage**|
||**50 Hz**|**60 Hz**|||||
|12 VDC|---|---|15 mA|10.8V|1V|±10%|
|24 VDC|---|---|12 mA|21.6V|||
|24 VAC/DC|20 mA|21 mA|11 mA|21.6V|||
|48 VAC/DC|10 mA|11 mA|6 mA|43.2V|||
|110 VAC|7.5 mA|8.2 mA|---|99V|||
|230 VAC|7.3 mA|8.6 mA|---|207V|||
|**G3RV-SL700/500-AL Series**|||||||
|**Rated voltage**|**Rated current**|||**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Input voltage**|
||**AC**||**DC**|||**% of rated voltage**|
||**50 Hz**|**60 Hz**|||||
|12 VDC|---|---|15 mA|10.8V|1V|±10%|
|24 VDC|---|---|12 mA|21.6V|||
|24 VAC/DC|20 mA|21 mA|11 mA|21.6V|||
|48 VAC/DC|10 mA|11 mA|6 mA|43.2V|||
|110 VAC|7.5 mA|8.2 mA|---|99V|||
|230 VAC|7.3 mA|8.6 mA|---|207V|||
|**G3RV-SL700/500-D Series**|||||||
|**Rated voltage**|**Rated current**|||**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Input voltage**|
||**AC**||**DC**|||**% of rated voltage**|
||**50 Hz**|**60 Hz**|||||
|12 VDC|---|---|8 mA|10.8V|1V|±10%|
|24 VDC|---|---|4.5 mA|21.6V|||
|24 VAC/DC|10.7 mA|11.1 mA|4.3 mA|21.6V|||
|48 VAC/DC|9.6 mA|10.2 mA|6 mA|43.2V|||
|110 VAC|6.8 mA|7.5 mA|---|99V|||
|230 VAC|6.8 mA|8.1 mA|---|207V|||
## **Output**
|**Output**|||
|---|---|---|
|**Item**|**G3RV-SL700/500-A(L)**|**G3RV-SL700/500-D**|
|**Rated load voltage**|AC100~240V (50/60Hz)|DC5~24V|
|**Load voltage range**|AC75~264V (50/60Hz)|DC3~26.4V|
|**Load current**|0.1~2A (Ta=40°C)|100µA~3A (Ta=40°C)|
|**Inrush current**|30A (60Hz/1cycle)|30A (60Hz/1cycle)|
|**Permissible I2t ; Joule Integral**<br>**(Reference value)**|15A2s|9A2s|
|**Application load capacity**|400W<br>(Output voltage: AC200V)|72W<br>(Output voltage: DC24V)|
Solid State Relays **G3RV**
2
## ■ **Characteristics**
|■**Characteristics**||||
|---|---|---|---|
|**Item**|**G3RV-SL700/500-A**|**G3RV-SL700/500-AL**|**G3RV-SL700/500-D**|
|**Operate time**|1/2 of load power source cycle<br>+ 1 ms max.|1 ms max.|6 ms max.|
|**Release time**|40 ms max.|20 ms max.|60 ms max.|
|**Output ON voltage drop**|1.6 V rms max.||0.9 V max.|
|**Leakage current**|5 mA max. (at 200 VAC 50/60Hz)||10 µA max. (at 24VDC)|
|**Insulation resistance**|100 MΩmin. (at 500 VDC)|||
|**Dielectric strength**|AC2500V 50/60 Hz for 1 min between input and output|||
|**Vibration resistance**|Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude|||
|**Shock resistance**|300m/s2|||
|**Ambient temperature**|Storage: -30~+100°C (with no icing or condensation)<br>Operating: -30~+55°C (with no icingor condensation)|||
|**Ambient humidity**|45~85%RH|||
|**Weight**|Approx. 38g|||
|**Pollution degree**|2|||
|**Degree of protection according**<br>**to IEC 60529**|IP20|||
|**Rated Impulse Withstand**<br>**Voltage**|4.0kV / III|||
|**Load category**|LC-A||DC-12|
|**Overload Current Profile**|1.5Ie 1.1Ue<br>5s ON, 10s OFF, 10cycles|||
|**Rated insulation Voltage**|240V|||
## ■ **Approved Standards**
## **UL 508 (File No. E64562)**
|**Model**|**Input ratings**|**Contact ratings**|
|---|---|---|
|G3RV-SL700/500-D Series|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|24 VDC 3 A (Resistive Load) at 25°C|
|G3RV-SL700/500-A(L) Series|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|240 VAC 2 A (Resistive Load) at 25°C|
## **IEC/TUV (EN 62314)**
|**IEC/TUV (EN 62314)**||
|---|---|
|**Input ratings**|**Contact ratings**|
|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|24 VDC 3 A (Resistive Load)|
|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|240 VAC 2 A (Resistive Load)|
Solid State Relays **G3RV**
3
## **En ineerin Data g g**
## ■ **Load current derating curves**
## **- - G3RV SL700/500 A(L) Series**
Mounting Distance 10mm
**==> picture [88 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Distance 0mm<br>**----- End of picture text -----**<br>
## **- - G3RV SL700/500 D Series**
Mounting Distance 10mm
Mounting Distance 0mm
## ■ **One Cycle Surge Current: Non-repetitive**
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents.
## **- - G3RV SL700/500 A(L) Series**
## **- - G3RV SL700/500 D Series**
Solid State Relays **G3RV**
4
## **Accessories**
## ■ **PLC Interface (for G2RV-SL700 & G3RV-SL700 series only)**
## **List of Models**
|**List of Models**|||
|---|---|---|
|**Model number**|**Description**|**Connection**|
|P2RVC-8-O-F|PLC Output Interface for 8x<br>G2RV-SL700 & G3RV-SL700 series<br>PNP - type|Ribbon cable connector<br>10 Pole, IEC603/1|
## **Specifications**
|**Input**|**Rated voltage**<br>**Current capacity**|30 VAC/VDC max.|
|---|---|---|
|||0.5 A per channel|
|||2.0 A total current, power supply terminal|
|**Characteristics**|**Ambient temperature**<br>**Overvoltage category**<br>**Pollution degree**|Operating: 0 to 55°C<br>Storage:<br>−20 to 85°C|
|||III|
|||2|
## **Electrical schematic P2RVC-O-8-F**
Solid State Relays **G3RV**
5
## ■ **SSR for Maintenance (Replacement SSRs)**
## **Model Number Legend**
## **G3RV-** @ @ @ @
**1 2 3 4**
## **1. Output voltage specifications**
- D: DC Output
- 2: AC Output
## **2. Rated Current**
- 02: AC Output 2A
- 03: DC Output 3A
## **3. Terminals**
- S: Plug-In
## **4. Zero cross function**
Blank: with Zero cross function
- L : without Zero cross function
## **List of Models**
|**Isolation**|**Movement**<br>**indication**|**Rated input**<br>**voltage**<br>**(Socket)**|**Output**<br>**(SSR)**|**Zero cross**<br>**function**|**Rated**<br>**output**<br>**load***|**Model Number**|**Replacement for**|
|---|---|---|---|---|---|---|---|
|Phototriac|Yes (Green)|DC12V|AC|Yes|2A at 100<br>to 240VAC|G3RV-202S DC12|G3RV-SL700/500-A DC12|
|||DC24V||||G3RV-202S DC24|G3RV-SL700/500-A DC24|
|||AC/DC24V|||||G3RV-SL700/500-A AC/DC24|
|||AC/DC48V|||||G3RV-SL700/500-A AC/DC48|
|||AC110V||||G3RV-202S DC48|G3RV-SL700/500-A AC110|
|||AC230V|||||G3RV-SL700/500-A AC230|
|||DC12V||No||G3RV-202SL DC12|G3RV-SL700/500-AL DC12|
|||DC24V||||G3RV-202SL DC24|G3RV-SL700/500-AL DC12|
|||AC/DC24V|||||G3RV-SL700/500-AL AC/DC24|
|||AC/DC48V|||||G3RV-SL700/500-AL AC/DC48|
|||AC110V||||G3RV-202SL DC48|G3RV-SL700/500-AL AC110|
|||AC230V|||||G3RV-SL700/500-AL AC230|
|Photocoupler||DC12V|DC|---|3A at 5 to<br>24 VDC|G3RV-D03SL DC12|G3RV-SL700/500-D DC12|
|||DC24V||||G3RV-D03SL DC24|G3RV-SL700/500-D DC24|
|||AC/DC24V|||||G3RV-SL700/500-D AC/DC24|
|||AC/DC48V||||G3RV-D03SL DC48|G3RV-SL700/500-D AC/DC48|
|||AC110V|||||G3RV-SL700/500-D AC110|
|||AC230V|||||G3RV-SL700/500-D AC230|
- *different by ambient temperature.
Please refer to 4 pages of characteristic data “ ■ Load current derating curves” for the details.
Solid State Relays **G3RV**
6
## ■ **Cross bars**
## **Model Number Legend**
## **P2RVM -** @ @
**1 2 Number of Poles 2. Color** 020: 2 poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black 100: 10 poles 200: 20 poles
**1. Number of Poles 2. Color**
## **List of Models**
|**Model number**|**Poles**|**Quantity**|**Color**|
|---|---|---|---|
|P2RVM-020@|2|60 pcs / box (minimum order)|Red (R)<br>Blue (S)<br>Black (B)|
|P2RVM-030@|3|60 pcs / box (minimum order)||
|P2RVM-040@|4|60 pcs / box (minimum order)||
|P2RVM-100@|10|20 pcs / box (minimum order)||
|P2RVM-200@|20|20 pcs / box (minimum order)||
@ select color: R = Red, S = Blue, B = Black
## **Specification**
|**Specification**||
|---|---|
|Max current<br>(EN60947-7-1 section 8.3.3 / 1991)|32A|
|Max. Voltage|400 VAC|
|Max. Voltage<br>when cutting Cross-bar without using separation<br>plate or end-bracket|250 VAC|
## ■ **Plastic Labels for G2RV/G3RV Sockets**
**Model number Box quantity Color** R99-15 for G2RV 5 sheets × 120 labels = White 600 labels (minimum order) ~~ee ee~~
## ■ **Labels (Stickers) for G2RV/G3RV Sockets**
|**Model number**|**Box quantity**|**Color**|
|---|---|---|
|R99-16 for G2RV|10 sheets×484 labels =<br>4,840 labels (minimum order)|White|
Solid State Relays **G3RV**
7
## ■ **Separating Plates**
|**Model number**|**Quantity**|**Description**|
|---|---|---|
|P2RV-S<br>50 plates|50 plates|Provides isolation between<br>adjacent relays to achieve<br>400 V isolation.|
## **Dimensions**
**Note:** All units are in millimeters unless otherwise indicated.
## **Complete Unit**
## **G3RV-SL700**
**==> picture [53 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input circuit<br>**----- End of picture text -----**<br>
**==> picture [378 x 377] intentionally omitted <==**
**----- Start of picture text -----**<br>
106.7 max.<br>83<br>70.9<br>47.2<br>6.2 max. 26.1<br>so, | (OTR 1S<br>24 V DC Other Input Voltage<br>35 Terminal Arrangement/ Terminal Arrangement/<br>Internal Connections Internal Connections<br>92.7 max. (Top View) (Top View)<br>i]<br>Five, 88.9 7.1<br>M2.5 × 6 99.2 r e<br>| “CoH<br>i @—+6<br>1 @ ><br>12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br>
Solid State Relays **G3RV**
8
## **G3RV-SL500**
## **Input circuit**
**==> picture [509 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
106.7 max.<br>82.9<br>69.8<br>46<br>6.2 max. 24.6<br>24 V DC Other Input Voltage<br>Terminal Arrangement/ Terminal Arrangement/<br>35 Internal Connections Internal Connections<br>97.4 max. (Top View) (Top View)<br>88.9 7.1<br>99.2<br>**----- End of picture text -----**<br>
**==> picture [72 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br>
## **Solid State Relay**
## **G3RV-D03SL G3RV-202S(L)**
**==> picture [171 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
���������<br>���<br>��� ��<br>���� �<br>�������<br>����<br>���<br>��������<br>**----- End of picture text -----**<br>
**==> picture [71 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input circuit<br>G3RV-D03SL<br>**----- End of picture text -----**<br>
**==> picture [122 x 77] intentionally omitted <==**
## **G3RV-202S(L)**
**==> picture [122 x 77] intentionally omitted <==**
**==> picture [72 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal Arrangement/<br>Internal Connections<br>(Bottom View)<br>**----- End of picture text -----**<br>
Solid State Relays **G3RV**
9
**Installation**
## ■ **Tools**
G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables.
G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables.
## **Applicable Screwdriver**
- Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
- Flat-blade, Parallel-tip
- 2.5 dia. (3.0 mm max.)
- Flat-blade, Flared-tip
**Cannot be used.**
Examples: FACOM AEF.2.5 × 75E (AEF. 3 × 75E) VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100) WAGO 210-119 WIHA 260/2.5 × 40 (260/3 × 50)
- *Chamfering the tip of the driver improves insertion when used as an exclusive tool.
## ■ **Applicable Wires**
## **Applicable Wire Sizes**
## **G3RV-SL700 Series**
## **Box clamp technology**
|**Box clamp technology**|||
|---|---|---|
|**Wire type**|**Applicable wire size**|**Stripping length**|
|Stranded without ferrules|0.5 - 1.5 mm2|7 mm|
|Stranded with ferrules and plastic collar|0.5 - 1.5 mm2|7 mm|
|Stranded with ferrules without plastic collar|0.5 - 1.5 mm2|7 mm|
|Solid|0.5 - 1.5 mm2|7 mm|
## **G3RV-SL500 Series**
## **Push-in technology**
|**Push-in technology**|||
|---|---|---|
|**Wire type**|**Applicable wire size**|**Stripping length**|
|Stranded without ferrules|0.5 - 1.5 mm2|12 mm|
|Stranded with ferrules and plastic collar|0.5 - 1.5 mm2|12 mm|
|Stranded with ferrules without plastic collar|0.5 - 1.5 mm2|12 mm|
|Solid|0.5 - 1.5 mm2|12 mm|
## **Tightening torque**
## **G3RV-SL700 Series: 0.4Nm**
Solid State Relays **G3RV**
10
## ■ **Wiring**
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series.
**==> picture [172 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
G3RV-SL700<br>7 mm<br>G3RV-SL500<br>12 mm<br>Fig. 1 Exposed Conductor Length<br>**----- End of picture text -----**<br>
**- Wiring Procedure for G3RV SL500 series**
Screwdriver hole Wire connection hole
● **Wiring**
**==> picture [69 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
● Removing<br>**----- End of picture text -----**<br>
Wire (2 ~~. Le~~ Insert the specified screwdriver into the release hole.
Insert the exposed conductor into the connection hole.
No other tools are required.
Removing wire.
**Note:** In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire.
Removing screwdriver.
Solid State Relays **G3RV**
11
## **Precautions**
## **Precautions for Connection**
- Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation.
- Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit.
- If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator.
- Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly.
## **General Precautions**
- Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance.
- Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator.
- Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock.
- Do not pour water or cleansing agents on the product. Doing so may result in electric shock.
- Do not use the socket in locations subject to solvents or alkaline chemicals.
- Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration.
- Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks.
- Insert the screwdriver along the hole wall as shown below. ecece
- Do not dispose the product in fire.
## **Removing from Mounting Rail**
To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. ~~—~~
**==> picture [32 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Screwdriver<br>**----- End of picture text -----**<br>
Solid State Relays **G3RV**
12
## **Definition of Precautionary Information**
Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate **WARNING** injury, or may result in serious injury or death. Additionally there may be significant property damage.
**CAUTION** A potentially hazardous situation by misuse, may result in property damage only accident.
- Handling
- Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and burning.
- Do not install G3RV Relay with bent terminals into the socket. Doing so could lead to poor electrical connection and hazardous conditions.
- Be sure to mount G3RV's with clean hands. Performing mounting with oil stained hands or coated with metal powder could result in hazardous outcomes.
- Mounting
## **CAUTION**
Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's terminal (Charging part) while the power supply turned on.
The G3RV may occasionally rupture in case of a short circuit.
To protect against short-circuit accident, install a protective device, such as a quick-burning fuse or a circuit breaker or the like, on the power supply.
Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's main circuit terminals immediately after the power is turned OFF. The internal snubber circuit is charged. * 202S,SL,G3RV-A(L) Type only
Minor hazard by burns may occasionally occur. Do not touch the G3RV or the heat sink either while the power supply is ON, or immediately after the power is turned OFF. The G3RV and the heat sink will be hot.
## **Precautions for Safe Use**
- Shipping
When shipping the G3RV, be sure to avoid the following:
- Conditions where the G3RV is exposed to water.
- High ambient temperatures and humidity.
- Be sure to mount the G3RV in the specified orientation. Mounting the G3RV in a different orientation could lead to abnormal heat generation causing output elements to short leading to burning.
- G3RV's are SSR's and generate heat. Be sure to control ambient temperature in setting where G3RV is used. If mounted in an enclosed space, install a fan to insure G3RV is properly ventilated.
- Be sure that the G3RV clicks into place when mounting it to DIN Track. The G3RV may fall if it is not mounted correctly.
- Wiring
- Use a wire an adequate size for current to be applied. Abnormal heating of wire may cause burning.
- Do not use any wires with damaged sheaths. These may cause electric shock.
- Confirm that wiring to G3RV Socket is not used in pipe or duct for high voltage power supply. Using a wire in pipe or duct connected to high voltage power supply will generate induction causing malfunction or damage.
- Be sure to conduct wiring with the power supply turned OFF. Touching the terminals when they are charged may occasionally result in minor electric shock.
- Using
- Select a load within the rated range. Inappropriate load may cause misoperation, trouble or burning.
- Select the power supply within the rated frequency range. Inappropriate power frequency may cause misoperation, trouble or burning.
- Inadequate packaging
Failure to avoid these conditions while shipping G3RV will lead to damage, malfunction, or deterioration.
- Operating and Storage Locations
Do not use or store the G3RV in the locations listed below. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics.
- Locations subject to rain or water drops.
- Locations subject to exposure to water, or oil, or chemicals.
- Locations subject to high temperatures or high humidity.
- Locations subject to ambient temperatures outside the range from -30 to +100 centigrade.
## **Precautions for Correct Use**
- G3RV uses electronics parts inside, so that any dropping, vibration, and physical shock beyond the standard level should be prevented. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics.
- Be sure to use tightening torque of 0.4 N·m for screw terminal G3RV. Failure to do so could result in short circuit failure and burning.
- Be sure to use proper voltage/current to G3RV input and output terminals. Failure to do so could result in short circuit failure and burning.
- Locations subject to relative humidity outside the range 45% to 85%.
- Locations subject to corrosive or flammable gases.
- Locations subject to dust (especially iron dust) or salts.
- Locations subject to barrier.
- Locations subject to static electricity or other forms of noise.
- Locations subject to strong electromagnetic fields.
- Locations subject to possible exposure to radioactivity.
Solid State Relays **G3RV** 13
## ● Mounting
## <Ventilation Outside the Control Panel>
<SSR Mounting Pitch (Panel Mounting)>
**==> picture [135 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Duct<br>60mm min.<br>SEEEE<br>SSR<br>Arh<br>Vertical<br>direction<br>SGr==<br>30mm min.<br>80mm min.<br>**----- End of picture text -----**<br>
**==> picture [175 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Be aware of air flow<br>Duct<br>Ventllation<br>outlet<br>SSR SSR SSR<br>Air inlet<br>**----- End of picture text -----**<br>
- If the air inlet or outlet has a filter, clean the filter regularly to prevent it from clogging and ensuring efficient flow of air.
- Do no locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel.
- A heat exchanger, if used, should be located in front of the G2RVs to ensure the efficiency of the heat exchanger.
- Please monitor the ambient temperature of the G3RV's. The rated load current is measured at 25°C ambient temperature.
- A G3RV uses semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To the restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the G3RVs and thus increase reliability.
- (Generally, each 10°C reduction in temperature will double the expected life.)
- EMI
- This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference.
## **Suitability for Use**
## <Relations between SSR and duct (Depth of duct)>
**==> picture [229 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Duct Depth Counter measure(1) Counter measure(2)<br>The recommended width is<br>Duct or air flow obstruction 1/2 as large as the depth of SSR or less Duct or air flow obstruction<br>“4 x a | 4 Pu<br>Z,—1 The depth of SSR Duct or air flow obstruction Air flow<br>Vertical direction Metal base<br>SSR SSR SSR<br>gZ—| Duct or air flow obstruction Za Duct or air flow } Duct or air flow obstruction |<br>obstruction<br>Do not surrounded the SSR Use a short duct in If the height of the ducts<br>with the duct in the depth the depth direction. can not be lowered, place<br>direction, or otherwise the the SSR or a metal base so<br>heat radiation of the S5R that they are not<br>will be adversely affected. surrounded by the ducts.<br>**----- End of picture text -----**<br>
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.**
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J180-E 2 -02
**In the interest of product improvement, specifications are subject to change without notice.**
Solid State Relays **G3RV**
14
Updated at June 10, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →