G3DZ-F4PU DC24
MOSFET RELAY, 4PST-NO, 24VDC, 0.3A, SKT
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: MOSFET Solid State Relays
- Load Type: AC / DC
- Contact Form: 4PST-NO (4 Form A)
- Load Current: 300mA
- Product Range: G3DZ Series
- Relay Mounting: DIN Rail
- Relay Terminals: Screw
- Load Voltage Max: 264V
- Isolation Voltage: 2kV
- On State Resistance Max: 2.4ohm
- MOSFET Relay Package Style: Module
- Off State Leakage Current Max: 10µA
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 141.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
**New Product** ## **Terminal Relay G6D-F4PU/G3DZ-F4PU (Push-In Plus Technology) G6D-F4B/G3DZ-F4B (Screw Terminal)** ## **Model with Push-In Plus technology Added to Terminal Relays with Four-point Output Lineup** **==> picture [107 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> G6D-F4PU G6D-F4B<br>G3DZ-F4PU G3DZ-F4B<br>**----- End of picture text -----**<br> - Realized 5 A rating by optimal designs for wide variety of applications (Push-In Plus technology). - Push-In Plus terminal enables work reduction and requires no retightening. - Short Bars (order separately) ensure easy common wiring and crossover wiring to adjacent terminal relays. - Double wire method enables branch wiring (Push-In Plus technology) - Each relay has independent coils and contacts for PLC output compatible (both NPN and PNP). - Mechanical Relay models and power MOS FET relay models (for high frequency contact ratings) are available. - LED operation indicator, diode for coil surge absorption, and tools for easy removal of relays are included as standard equipment. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. **Refer to** _**Safety Precautions**_ **on page 12.** - UL and CSA certification for standard models. - VDE certification for Screws terminal, TÜV certification for Push-In Plus terminal. IP20 protection code for Push-In Plus models. ## **Features (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology))** **==> picture [125 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Pursuing High Usability<br>**----- End of picture text -----**<br> **==> picture [237 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Short Bars enable common wiring<br>Easy common wiring with Short Bars<br>Tools for<br>removal J eroee one<br>FUTUR UUUUUUUUUeUeld<br>A |<br>LED operation Independent circuit for PLC output<br>indicator in both NPN and PNP<br>*<br>Branch wiring with double wire<br>method<br>**----- End of picture text -----**<br> **==> picture [260 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Slimmer Width Yet Larger Power Supply Capacity<br>**----- End of picture text -----**<br> **==> picture [221 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> Rated load: 3A Rated load: 5A Rated load: 5A<br>capacity byapprox.currentLarger width bySlimmerapprox.<br>67% 30%<br>ces »> <€ aad<br>Width: 31 mm Width: 31 mm Width: 43 mm<br>G6D-F4B G6D-F4PU G6B-4BND<br>(Screw) (Push-In Plus technology) (Screw)<br>NEW<br>**----- End of picture text -----**<br> **==> picture [143 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Wide Variety of Application<br>**----- End of picture text -----**<br> **Applicable to Various Number of I/O Points** **==> picture [138 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Short Hight for Installation in Narrow Spaces<br>**----- End of picture text -----**<br> **==> picture [499 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> G2RV-SR G6D-F4PU<br>a =<br>Ei:<br>1 point 4 point<br>Operating panel of each device, etc.<br>- ia. P G2RV-SR G70V<br>~. _—= =7 = ——— i | Tn :<br>8 point 16 point<br>| ™s f=<br>Connector terminal box, etc. Control box, etc.<br> Value Design for Panel<br>Our shared concept “Value Design for Panel” for the specifications of products used in control panels (hereinafter called “Value Design”) will create new<br>value to your control panels. Combining multiple products that share the Value Design concept will further increase the value provided to control panels.<br>**----- End of picture text -----**<br> **==> picture [102 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Connector terminal box, etc.<br>**----- End of picture text -----**<br> - Value Design for Panel **1** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Ordering Information** ## **When your order, specify the rated voltage.** ## **Main unit** ## **Model with Push-In Plus technology** |Mounted Relay type|Contact form|Model|Operation coil ratings| |---|---|---|---| |Mechanical Relay|SPST x 4<br>(1NO x 4)|**G6D-F4PU**|12 VDC| ||||24 VDC| |Power MOS FET relay||**G3DZ-F4PU**|12 VDC| ||||24 VDC| ## **Model with Screw Terminal** |Mounted Relay type|Contact form|Model|Operation coil ratings| |---|---|---|---| |Mechanical Relay models|SPST x 4<br>(1NO x 4)|**G6D-F4B**|12 VDC| ||||24 VDC| |Power MOS FET relay||**G3DZ-F4B**|12 VDC| ||||24 VDC| ## **Accessories (Order Separately)** ## � **Connection socket (single sales available)** ## **G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology)** |Model|Operation coil ratings| |---|---| |**P6DF-F4PU**|12 VDC| ||24 VDC| ## **G6D-F4B/G3DZ-F4B (Models with Screw terminal)** |Model|Operation coil ratings| |---|---| |**P6DF-F4B**|12 VDC| ||24 VDC| **Note: 1.** Connection socket P6DF-F4B as a single part is not certified by safety standards individually. **2.** Single socket which does not mount a relay (with cover). ## � **Short Bar (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology))** |Pitch|Applicable models|Number of<br>poles|Color|Model*1| |---|---|---|---|---| |7.75 mm|G6D-F4PU<br>G3DZ-F4PU<br>P6DF-F4PU|2|Red (R)<br>Blue (S)<br>Yellow (Y)|**PYDN-7.75-020**@| |||3||**PYDN-7.75-030**@| |||4||**PYDN-7.75-040**@| |||20||**PYDN-7.75-200**@| **Note:** Use the Short Bars for crossover wiring within one Socket or between Sockets. - *1. Replace the box (@) in the model number with the code for the covering color. Selection of the box (@): R=Red, S=Blue, Y=Yellow ## � **Short Bar (G6D-F4B/G3DZ-F4B (Model with Screw Terminal))** |Applicable Terminal<br>Relay Model|Model| |---|---| |G6D-F4B|**G6D-4-SB**| |G3DZ-F4B|| **2** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Replacement Relay (G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology))** Applicable Terminal Relay Model Model Operation coil ratings 12 VDC G6D-F4PU/G6D-F4B **G6D-1A-ASI** 24 VDC 12 VDC G3DZ-F4PU/G3DZ-F4B **G3DZ-2R6PL** 24 VDC **==> picture [355 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> G3DZ-F4PU/G3DZ-F4B G3DZ-2R6PL<br>24 VDC<br>Parts for DIN Track Mounting<br>Appearance Type Model<br>(gq<br>1 m PFP-100N<br>DIN Tracks<br>0.5 m PFP-50N<br>Al<br>|<br>End Plate *1 PFP-M<br>=<br>Spacer PFP-S<br>~~<br>*1. When mounting support rail, please use End Plate (Model PFP-M).<br>**----- End of picture text -----**<br> **3** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B Ratings/Specifications** ## **Ratings** ## � **Relay Specification** **Coil Ratings (per G6D Relay)** |Operation<br>coil rating|Operation<br>coil rating|Rated<br>current<br>(mA)|Coil<br>resistance<br>(Ω)|Must<br>operate<br>voltage<br>(V)|Must<br>release<br>voltage<br>(V)|Max.<br>voltage<br>(V)|Power<br>consump<br>tion<br>(mW)| |---|---|---|---|---|---|---|---| |DC|12|18.7|720|70%<br>max.*|10%<br>min.|130%|Approx.<br>200| ||24|10.5|2,880||||| - **Note: 1.** Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±20%. **2.** Performance characteristic data are measured at a coil temperature of 23°C. **3.** The maximum allowable voltage is the maximum value of the operating voltage for the relay coil operating power supply. There is no continuous allowance. **4.** The rated current includes the terminal’s LED current. - The must operate voltage is 75% or less of the rated voltage if the relay is mounted in the upside down. ## **Contact Ratings (per G6D Relay)** ## **G6D-F4PU (Model with Push-In Plus technology)** |Item<br>Load|Resistive load (cosφ= 1)| |---|---| |Rated load|5 A at 250 VAC, 5 A at 30 VDC| |Rated carry current|5 A| |Max. switching voltage|250 VAC, 30 VDC| |Max. switching current|5 A| |Max. switching capacity<br>(reference value)|1,250 VA, 150 W| ## **G6D-F4B (Model with Screw terminal)** |Item<br>Load|Resistive load (cosφ= 1)| |---|---| |Rated load|3 A at 250 VAC, 3 A at 30 VDC| |Rated carry current|5 A| |Max. switching voltage|250 VAC, 30 VDC| |Max. switching current|5 A| |Max. switching capacity<br>(reference value)|1,250 VA, 150 W| ## **Characteristics** ||Model|G6D-F4PU<br>(Model with Push-In Plus technology)| |---|---|---| |Item||Relay output| |Contact resis|tance*1|100 mΩmax.| |Operate time|*2|10 ms max.| |Release time|*2|10 ms max.| |Insulation res|istance|1,000 MΩmin. (at 500 VDC)| |Dielectric<br>strength|Between coil and<br>contacts|2,000 VAC, 50/60 Hz for 1 min| ||Between contacts<br>of the same polarity|750 VAC, 50/60 Hz for 1 min| |Shock resista<br>(between coil|nce voltage<br>and contacts)|4,000 V (1.2 × 50μs)| |Vibration re-<br>sistance|Destruction|10 to 55 to 10 Hz, 0.75-mm single amplitude<br>(1.5-mm double amplitude)| ||Malfunction|10 to 55 to 10 Hz, 0.75-mm single amplitude<br>(1.5-mm double amplitude)| |Shock<br>resistance|Destruction|500 m/s2| ||Malfunction|100 m/s2| |Endurance|Mechanical|20,000,000 operations min.<br>(switching frequency: 18,000 operations/hr)| ||Electrical*2|70,000 operations min.<br>(5 A at 250 VAC, resistive load)<br>70,000 operations min.<br>(5 A at 30 VDC, resistive load)<br>(at 1,800 switching frequencies/hr)| |Failure rate P<br>(reference va|Level<br>lue*3)|10 mA at 5 VDC| |Ambient operating temperature,<br>Ambient storage temperature||-25 to 55°C (with no icing)| |Ambient operating humidity||45% to 85%| |LED color||Yellow| |Sealing||IP20| |Weight||Approx. 95 g| **Note:** The data shown above are initial values. - *1. Measurement condition: 1 A at 5 VDC - *2. Ambient temperature condition: 23°C - *3. This value is measured at 120 switching frequencies/min. ||Model|G6D-F4B<br>(Model with Screw terminal)| |---|---|---| |Item||Relay output| |Contact resis|tance*1|100 mΩmax.| |Operate time|*2|10 ms max.| |Release time|*2|10 ms max.| |Insulation res|istance|1,000 MΩmin. (at 500 VDC)| |Dielectric<br>strength|Between coil and<br>contacts|2,000 VAC, 50/60 Hz for 1 min| ||Between contacts<br>of the same polarity|750 VAC, 50/60 Hz for 1 min| |Shock resista<br>(between coil|nce voltage<br>and contacts)|4,000 V (1.2 × 50μs)| |Vibration re-<br>sistance|Destruction|10 to 55 to 10 Hz, 0.75-mm single amplitude<br>(1.5-mm double amplitude)| ||Malfunction|10 to 55 to 10 Hz, 0.75-mm single amplitude<br>(1.5-mm double amplitude)| |Shock<br>resistance|Destruction|500 m/s2| ||Malfunction|100 m/s2| |Endurance|Mechanical|20,000,000 operations min.<br>(switching frequency: 18,000 operations/hr)| ||Electrical*2|200,000 operations min.<br>(3 A at 250 VAC, resistive load)<br>200,000 operations min.<br>(3 A at 30 VDC, resistive load)<br>(at 1,800 switching frequencies/hr)| |Failure rate P<br>(reference va|Level<br>lue*3)|10 mA at 5 VDC| |Ambient operating temperature,<br>Ambient storage temperature||-25 to 55°C (with no icing)| |Ambient operating humidity||45% to 85%| |LED color||Yellow| |Sealing||---| |Weight||Approx. 65 g| **Note:** The data shown above are initial values. - *1. Measurement condition: 1 A at 5 VDC - *2. Ambient temperature condition: 23°C - *3. This value is measured at 120 switching frequencies/min. **4** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Ratings** ## � **Power MOS FET Relay Specifications Input (per G3DZ Power MOS FET Relay)** |Rated<br>voltage|Rated<br>voltage|Operating<br>voltage|Must<br>operate<br>voltage level|Must<br>release<br>voltage level|Input<br>impedance|Rated<br>current| |---|---|---|---|---|---|---| |DC|12|9.6 to 14.4<br>VDC|9.6 VDC<br>max.|1 VDC min.|2 kΩ ±20%|8.0 mA<br>±20%| ||24|19.2 to<br>28.8 VDC|19.2 VDC<br>max.||4 kΩ±20%|8.2 mA<br>±20%| **Note:** The rated current includes the terminal’s LED current. ## **Output (per G3DZ Power MOS FET Relay)** |Rated operating<br>voltage|Load voltage<br>range|Load current|Inrush current<br>resistance| |---|---|---|---| |5 to 240 VAC<br>5 to 100 VDC|3 to 264 VAC<br>3 to 125 VDC|100μto 0.3 A|6 A (10 ms)| **Note:** There is no output polarity for the G3DZ. ## **Characteristics** |Model|G3DZ-F4PU<br>(Model with Push-In Plus technology)| |---|---| |Item|Power MOS FET relay output| |Must operate time|10 ms max.| |Release time|15 ms max.| |Output ON-resistance|2.4Ωmax.| |Leakage current at OFF state|10μA max. (at 125 VDC)| |Insulation resistance|100 MΩmin. (at 500 VDC)| |Dielectric strength between I/O|2,000 VAC, 50/60 Hz for 1 min| |Vibration resistance|10 to 55 to 10 Hz, 0.75-mm single<br>amplitude (1.5-mm double amplitude)| |Shock resistance|500 m/s2| |Ambient operating temperature,<br>Ambient storage temperature|-25 to 55°C (with no icing)| |Ambient operating humidity|45% to 85%| |LED color|Yellow| |Sealing|IP20| |Weight|Approx. 95 g| |Model|G3DZ-F4B<br>(Model with Screw terminal)| |---|---| |Item|Power MOS FET relay output| |Must operate time|10 ms max.| |Release time|15 ms max.| |Output ON-resistance|2.4Ωmax.| |Leakage current at OFF state|10μA max. (at 125 VDC)| |Insulation resistance|100 MΩmin. (at 500 VDC)| |Dielectric strength between I/O|2,000 VAC, 50/60 Hz for 1 min| |Vibration resistance|10 to 55 to 10 Hz, 0.75-mm single<br>amplitude (1.5-mm double amplitude)| |Shock resistance|500 m/s2| |Ambient operating temperature,<br>Ambient storage temperature|-25 to 55°C (with no icing)| |Ambient operating humidity|45% to 85%| |LED color|Yellow| |Sealing|---| |Weight|Approx. 65 g| **5** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Ratings for Safety Standard Certification** The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. ## **G6D-F4PU/G3DZ-F4PU** ## � **UL-certified Models (File No. E41515)** |Model|Standard<br>number|Category|Listed/<br>Recognition<br>Classification|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---|---|---|---| |G6D-F4PU|UL508|NRNT/7|Listed|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>30 VDC<br>Load Current, General Use and Resistive<br>5 A at 40°C|Mechanical<br>20,000,000 operations min.<br>(at 18,000 switching<br>frequencies/hr)<br>Electrical<br>70,000 operations (5 A at 250<br>VAC, resistive load)<br>70,000 operations (5 A at 30<br>VDC, resistive load)<br>(at 1,800 switching<br>frequencies/hr)| |G3DZ-F4PU||||||Rated load voltage<br>5-240 VAC<br>5-100 VDC<br>Load Current, General Use and Resistive<br>0.3 A at 55°C|---| |P6DF-F4PU||SWIV2|Recognition|||Contact terminal<br>5 A, 250 V|---| ## � **CSA-certified Models (File No. LR35535)** |Model|Standard number|Class number|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---|---|---| |P6DF-F4PU|C22.2 NO. 14|CLASS 3211 07<br>CLASS 3211 87|12 VDC<br>24 VDC|4|Contact terminal<br>5 A, 250 V|---| ## � **TÜV Rheinland Certification (Certification No.R50429253)** |Model|Operating<br>Coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |G6D-F4PU|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>30 VDC<br>Load Current, General Use and Resistive<br>5 A at 40°C|Mechanical<br>1,000,000 operations<br>(at 18,000 switching<br>frequencies/hr)<br>Electrical<br>70,000 operations (5 A at 250<br>VAC, resistive load)<br>70,000 operations (5 A at 30<br>VDC, resistive load)<br>(at 1,800 switching<br>frequencies/hr)| ## � **TÜV Rheinland Certification (Certification No.R50429249)** |Model|Operating<br>Coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |G3DZ-F4PU|12 VDC<br>24 VDC|4|Rated load voltage<br>5-240 VAC<br>5-100 VDC<br>Load Current, General Use and Resistive<br>0.3 A at 55°C|---| ## � **TÜV Rheinland Certification (Certification No.50429224)** |Model|Operating<br>Coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |P6DF-F4PU|12 VDC<br>24 VDC|4|Contact terminal<br>5 A, 250 V|---| **6** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **G6D-F4B/G3DZ-F4B** ## � **UL-certified Models (File No. E87929)** |Model|Standard<br>number|Category|Listed/<br>Recognition<br>Classification|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---|---|---|---| |G6D-F4B|UL508|SWIV2|Recognition|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>30 VDC<br>Load Current<br>5 A, Resistive|---| |G3DZ-F4B||||||Rated load voltage<br>3-264 VAC<br>3-125 VDC<br>Load Current<br>0.3 A|---| ## � **CSA-certified Models (File No. LR35535)** |Model|Standard number|Class number|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---|---|---| |G6D-F4B|C22.2 NO. 14|CLASS 3211 07<br>CLASS 3211 87|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>30 VDC<br>Load Current<br>5 A, Resistive|---| |G3DZ-F4B|||||Rated load voltage<br>3-264 VAC<br>3-125 VDC<br>Load Current<br>0.3 A, Resistive|---| ## � **VDE Certification (Certification No.40017757)** |Model|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |G6D-F4B|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>24 VDC<br>Load Current<br>3 A|---| ## � **VDE Certification (Certification No.40046252)** |Model|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |G3DZ-F4B|12 VDC<br>24 VDC|4|Rated load voltage<br>5-240 VAC<br>5-100 VDC<br>Load Current<br>0.3 A|---| ## � **VDE Certification (Certification No.40046241)** |Model|Operating<br>coil ratings|Number<br>of poles|Contact ratings|Certified number of operations| |---|---|---|---|---| |P6DF-F4B|12 VDC<br>24 VDC|4|Rated load voltage<br>250 VAC<br>Load Current<br>0.3 A|---| **7** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Engineering Data** ## **Engineering Data** ## � **G6D-F4PU** **Maximum Switching Capacity** **==> picture [155 x 349] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>50<br>30<br>10<br>5<br>3<br>DC resistive load AC resistive<br>load<br>1<br>0.5<br>0.3<br>0.1<br>0 3 5 10 30 50 100 250 500<br>Switching voltage (V)<br>Load Current vs. Ambient Temperature<br>(Product specification)<br>5<br>4<br>3<br>2<br>1<br>0<br>-25 -20 0 20 40 55 60 80 100<br>Ambient temperature (˚C)<br>Switching current (A)<br>Load current (A)<br>**----- End of picture text -----**<br> ## **Load Current vs. Ambient Temperature (Product specification)** ## � **G6D-F4B** **Maximum Switching Capacity** **==> picture [154 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>50<br>30<br>10<br>5<br>3<br>DC resistive load AC resistive<br>load<br>1<br>0.5<br>0.3<br>0.1<br>0 3 5 10 30 50 100 250 500<br>Switching voltage (V)<br>Switching current (A)<br>**----- End of picture text -----**<br> ## **Endurance Curve** **==> picture [160 x 533] intentionally omitted <==** **----- Start of picture text -----**<br> 500<br>300<br>100<br>50 250 VAC, 30 VDC, Resistive load<br>30<br>10<br>5 250 VAC, 30 VDC, Inductive load<br>(cosФ=0.4 L/R=7 ms)<br>3<br>0 1 2 3 4 5 6 7 8 9 10<br>Switching current (A)<br>Load Current vs. Ambient Temperature<br>(Specifications with UL and TÜV<br>certification)<br>5<br>4<br>3<br>2<br>1<br>0<br>-25-20 0 20 40 55 60 80 100<br>Ambient temperature (˚C)<br>Endurance Curve<br>500<br>300<br>100<br>50 250 VAC, 30 VDC, Resistive load<br>30<br>10<br>5 250 VAC, 30 VDC, Inductive load<br>(cosФ=0.4 L/R=7 ms)<br>3<br>0 1 2 3 4 5 6 7 8 9 10<br>Switching current (A)<br>4Operation times (× 10 times)<br>Load current (A)<br>4Operation times (× 10 times)<br>**----- End of picture text -----**<br> **Load Current vs. Ambient Temperature (Specifications with UL and TÜV certification)** ## **Endurance Curve** **8** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## � **G3DZ-F4PU** ## **Load Current vs. Ambient Temperature Inrush current resistance** **==> picture [341 x 379] intentionally omitted <==** **----- Start of picture text -----**<br> Non-repetitive<br>(Keep the inrush current to below the inrush current resistance<br>value (i.e., below the broken line) if it occurs repetitively.)<br>1 10<br>0.8<br>8<br>0.6 6<br>0.4<br>4<br>0.3<br>0.2 2<br>0-25 -20 0 20 40 55 60 80 100 0 5 10 30 50 100 300 500 1,000 3,000 5,000<br>Ambient temperature (˚C) Energizing time (ms)<br>� G3DZ-F4B<br>Load Current vs. Ambient Temperature Inrush current resistance<br>Non-repetitive<br>(Keep the inrush current to below the inrush current resistance<br>value (i.e., below the broken line) if it occurs repetitively.)<br>1 10<br>0.8<br>8<br>0.6 6<br>0.4 4<br>0.3<br>0.2 2<br>0 0<br>-25 -20 0 20 40 55 60 80 100 5 10 30 50 100 300 500 1,000 3,000 5,000<br>Ambient temperature (˚C) Energizing time (ms)<br>Load current (A) Inrush current (A.Peak)<br>Load current (A) Inrush current (A.Peak)<br>**----- End of picture text -----**<br> **Note:** These data are actual measured values that were sampled from the production line and prepared in graph format, and are for reference purposes only. A relay is manufactured by mass production, and as a basic rule must be used with allowance made for a certain amount of deviation. **Note:** These data are actual measured values that were sampled from the production line and prepared in graph format, and are for reference purposes only. A relay is manufactured by mass production, and as a basic rule must be used with allowance made for a certain amount of deviation. **9** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** **Dimensions** **(Unit: mm)** ## **Main unit** ## **G6D-F4PU** ## **G3DZ-F4PU** **==> picture [418 x 303] intentionally omitted <==** **----- Start of picture text -----**<br> LED operation indicator<br>2-4 dia. or 2-M3.5<br>IN side 48 +- 37 +- 26 +- 15 +-<br>90.4 max. 108±0.3 1 2 3 4<br>100 max.<br>OUT side<br>12 11 10 9<br>16 15 14 13<br>Note: 1. Pay utmost attention not to make<br>mistakes with the polarity of the<br>Mounting Hole input terminals.<br>Tool for easy removal of relays 31 max. 30 Dimensions 2. There is no output polarity for<br>33.6 Note: Pull out the G6D-F4PU/G3DZ-F4PU.<br>= = 35 max. hooks to mount<br>the Relay with<br>Terminal Connection Examples screws.<br>4 - 3 - 2 - 1 -<br>8 + 7 + 6 + 5 +<br>272 9 |<br>12 11 10 9<br>16 15 14 13 AC (DC power supply is<br>also available.)<br>L4 L3 L2 L1<br>**----- End of picture text -----**<br> - **Note: 1.** Pay utmost attention not to make mistakes with the polarity of the input terminals. **2.** There is no output polarity for G6D-F4PU/G3DZ-F4PU. ## **G6D-F4B** **==> picture [509 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Hole Dimensions<br>G3DZ-F4B LED operation indicator 16-M3 Phillips screw 2-4 dia. or 2-M3.5 Terminal Arrangement/Internal<br>Connection Diagram<br>8.7 (Top View)<br>4 3 2 1<br>8 7 6 5 IN side 48 +- 37 +- 26 +- 15 +-<br>IN 1 2 3 4<br>; ea t | Gage<br>68 max. RY1 RY2 RY3 RY4 76±0.3 1 2 3 4<br>OUT OUT side<br>12 11 10 9<br>12 11 10 9 16 15 14 13<br>16 15 14 13<br>e e o8 [1 || ae<br>8.7 Note: 1. Pay utmost attention not to make<br>mistakes with the polarity of the<br>es 31 max. a 35 max. t |i : 23 4! ±0.3 aay<br>input terminals.<br>Tool for easy removal of relays 2. There is no output polarity for<br>G6D-F4B/G3DZ-F4B.<br>Terminal Connection Examples<br>4 - 3 - 2 - 1 -<br>8 + 7 + 6 + 5 +<br>72 9 |<br>12 11 10 9<br>16 15 14 13 AC (DC power supply is<br>also available.)<br>L4 L3 L2 L1<br>**----- End of picture text -----**<br> **10** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Accessories (Order Separately)** ## � **Short Bars** ## **PYDN-7.75-** @@ **(7.75 mm)** |**ort Bars**<br>||||||||| |---|---|---|---|---|---|---|---|---| |**N-7.75-**@@|3.9<br>1.57<br>12<br>18.5<br>**(7.75 mm)**|0<br>|Pitch|Applicable model|Number<br>of poles|<br>L (Length)|Color|Model*| ||||7.75 mm|G6D-F4PU<br>G3DZ-F4PU<br>P6DF-F4PU|2|15.1|Red (R)<br>Blue (S)<br>Yellow (Y)|**PYDN-7.75-020**@| |~~L~~<br>25||||||||| ||||||3|22.85||**PYDN-7.75-030**@| ||||||4|30.6||**PYDN-7.75-040**@| ||||||20|154.6||**PYDN-7.75-200**@| ||||*Replace the box (@) in the model||number with the code for the cove|||ring color Selection of t| * Replace the box (@) in the model number with the code for the covering color. Selection of the box (@): R=Red, S=Blue, Y=Yellow **Note:** Use the Short Bars for crossover wiring within one Socket or between Sockets. ## � **Short Bars** ## **G6D-4-SB** **==> picture [80 x 41] intentionally omitted <==** **==> picture [212 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> 7.62 7.62 7.62<br>5.7<br>3.7<br>5<br>9.6<br>(28.56) 2.6<br>**----- End of picture text -----**<br> ## � **Parts for DIN Track Mounting** **DIN Tracks PFP-100N PFP-50N** **==> picture [258 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> 7.3 [±0.15]<br>4.5<br>35 [±0.3] 27 [±0.15]<br>1 5 25 10 25 25 10 25 15 (5)* 1<br>1,000 (500)* * () indicates the dimension of PFP-50N.<br>**----- End of picture text -----**<br> ## **End Plate** **==> picture [305 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> 1 0<br>PFP-M 6.2<br>1.8<br>M4 × 8<br>Pan head<br>screw 1<br>50 35.5 35.3<br>1.8<br>11.5<br>1 0 1.3<br>M4 Spring washer 4.8<br>**----- End of picture text -----**<br> ## **Spacer** **PFP-S** **==> picture [110 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> 16<br>5 1 2<br>34.8<br>44.3<br>16.5<br>**----- End of picture text -----**<br> **11** ## **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **Safety Precautions** ## **Be sure to read the Common Precautions for All Relays in the website.** ## **Warning Indications** |**Precautions**<br>**for Safe Use**|Supplementary comments on what to do or<br>avoid doing, to use the product safely.| |---|---| |**Precautions**<br>**for Correct**<br>**Use**|Supplementary comments on what to do or<br>avoid doing, to prevent failure to operate,<br>malfunction, or undesirable effects on product<br>performance.| ## **Precautions for Safe Use** ## � **Transport** - Do not transport the I/O Relay Terminal under the following locations. Doing so may occasionally result in damage, malfunction, or deterioration of performance characteristics. - Locations subject to water or oil - Locations subject to high temperature or high humidity - Locations subject to condensation as the result of rapid changes in temperature. - Do not transport a Socket when it is not packaged. Damage or failure may occur. ## � **Operating and Storage Environments** - Do not use or store the I/O Relay Terminal in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. - Locations subject to rainwater or water splashes. - Locations subject to exposure to water, oil, or chemicals. - Locations subject to high temperature or high humidity. - Storage at locations subject to ambient temperatures outside the range -25 to 55°C - Usage at locations subject to ambient temperatures outside the range -25 to 55°C - Locations subject to relative humidity outside the range 45% to 85% - Locations subject to condensation as the result of rapid changes in temperature. - Locations subject to corrosive or flammable gases. - Locations subject to dust, salts, or iron, or locations where there is salt damage - Locations subject to direct sunlight. - Locations subject to shock or vibration. ## � **Installation and Mounting** - Mount the I/O Relay Terminal in the specified direction. Otherwise excessive heat generated by the I/O Relay Terminal may occasionally cause burning. ## � **Installation and Wiring** - Use wires that are suited to the load current and voltage. Otherwise, excessive heat generated by the wires may cause burning or may cause the wire covering to melt, possibly leading to electric shock. - Do not use wires with a damaged outer covering. it may result in electric shock or ground leakage.it may result in electric shock or ground leakage. - Do not wire any wiring in the same duct or conduit as power or high-tension lines. Inductive noise may damage the I/O Relay Terminal or cause it to malfunction. - Do not apply a voltage or current that exceeds the rating to any terminal. Doing so may result in failure or burning. - Do not use a deforming Short Bars. Doing so may result in damage, malfunction, or deterioration of performance characteristics. ## � **Push-In Plus Terminal** - Do not wire anything to the release holes. - Do not tilt or twist the screwdriver while it is inserted into a release hole on the terminal. The terminal may be damaged. - Insert a flat-blade screwdriver into the release holes at an angle. The terminal may be damaged if you insert the screwdriver straight in. - Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. - Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. - Do not insert more than one wire into each terminal insertion hole. - To prevent wire materials from smoking or ignition, confirm wire ratings and use the wiring materials given in the following table. |Recommended wires|Stripping length<br>(Ferrules not used)| |---|---| |0.5 to 1.5 mm2/AWG20 to 16|8 mm| ## � **Application** - Select a load within the rated values. Not doing so may result in malfunction, failure, or burning. - The G6D may occasionally rupture if short-circuit current flows. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. - Use a power supply within the rated frequencies. Otherwise, malfunction, failure, or burning may occasionally occur. - Minor electrical shock may occasionally occur if you touch the power charging area such as the terminal wiring area. Always turn OFF the power supply before performing wiring. ## **Mounting Directions** - Mount the I/O Relay Terminal firmly to a DIN Track. Otherwise, the I/O Relay Terminal may fall off. - Do not handle the I/O Relay Terminal with oily or dusty (especially iron dust) hands. - Make sure that there is no excessive ambient temperature rise due to the heat generation of the I/O Relay Terminal. If the I/O Relay Terminal is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. **12** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** - Insert Short Bars so that the protrusion part of a Short Bar comes to the wire insertion side. If the Short Bar is inserted in the upside down direction, the Short Bar may not be inserted securely. **==> picture [214 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> NG OK<br>**----- End of picture text -----**<br> ## **Precautions for Correct Use** - Do not drop the Socket or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. - Use a power supply with low noise. ## � **G6D-F4PU/G3DZ-F4PU (Model with Push-In Plus technology)** ## **1. Connecting Wires to the Push-In Plus Terminal Part Names of the Terminal** **==> picture [62 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> Short bar insertion hole<br>Release hole<br>Terminal (insertion) hole<br>**----- End of picture text -----**<br> ## **Connecting Wires with Ferrules and Solid Wires** ## � **Recommended Ferrules and Crimp Tools** ## **Recommended ferrules** |<br>**wire**<br>**Ferrules**<br>**Conductor**<br>**length**<br>**(mm)**<br>**(mm2)**<br>**(AWG)**|<br>**wire**<br>**Ferrules**<br>**Conductor**<br>**length**<br>**(mm)**<br>**(mm2)**<br>**(AWG)**|**Stripping**<br>**length**<br>**[mm]**<br>**(Ferrules**<br>**used)**<br>**Recommended ferrules**<br>**Manufactured**<br>**by Phoenix**<br>**Contact**<br>**Manufactured**<br>**by**<br>**Weidmuller**<br>**Manufactured**<br>**by Wago**|**Stripping**<br>**length**<br>**[mm]**<br>**(Ferrules**<br>**used)**<br>**Recommended ferrules**<br>**Manufactured**<br>**by Phoenix**<br>**Contact**<br>**Manufactured**<br>**by**<br>**Weidmuller**<br>**Manufactured**<br>**by Wago**| |---|---|---|---| |**(mm2)**|||**ed**<br>**er**<br>**Manufactured**<br>**by Wago**| |0.25|24<br>8<br>10|10 AI0,25-8<br>H0.25/12|FE-0.25-8N-YE| |||12 AI0,25-10<br>---|---| |0.34|22<br>8<br>10|10 AI0,34-8<br>H0.34/12|FE-0.34-8N-TQ| |||12 AI0,34-10<br>---|---| |0.5|20<br>8<br>10|10 AI0,5-8<br>H0.5/14|FE-0.5-8N-WH| |||12 AI0,5-10<br>H0.5/16|FE-0.5-10N-WH| |0.75|18<br>8<br>10|10 AI0,75-8<br>H0.75/14|FE-0.75-8N-GY| |||12 AI0,75-10<br>H0.75/16|FE-0.75-10N-GY| |1/1.25|18/17<br>8<br>10|10 AI1-8<br>H1.0/14|FE-1.0-8N-RD| |||12 AI1-10<br>H1.0/16|FE-1.0-10N-RD| |1.25/1.5|17/16<br>8<br>10|10 AI1,5-8<br>H1.5/14|FE-1.5-8N-BK| |||12 AI1,5-10<br>H1.5/16|FE-1.5-10N-BK| - **Note: 1.** Make sure that the outer diameter of the wire coating is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. **2.** Make sure that the ferrule processing dimensions conform to the following figures. 8 to 10 mm 1.9 mm max. 2.6 mm max. Insert the solid wire or ferrule straight into the terminal until the end strikes the terminal. **==> picture [39 x 39] intentionally omitted <==** **==> picture [80 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Release hole<br>Terminal (insertion) hole<br>Ferrules or solid wires<br>**----- End of picture text -----**<br> - If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. ## **Connecting Stranded Wires** Use the following procedure to connect the wires to the terminal. **1.** Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10° and 15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. **2.** With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal. **3.** Remove the flat-blade screwdriver from the release hole. **==> picture [204 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> (1) (3) Flat-blade screwdriver (3) (1)<br>10° to 15°<br>(2)<br>(2) Stranded wires<br>**----- End of picture text -----**<br> ## **Checking Connections** - After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal. - To prevent short circuits, insert the stripped part of a stranded or solid wire or the conductor part of a ferrule until it is hidden inside the terminal insertion hole. - If you use recommended ferrules, part of the conductor may be visible after the ferrule is inserted into the terminal, but the product insulation distance will still be satisfied. **3.** Wires of AWG24 to AWG22/0.25 mm[2] to 0.34 mm[2] are not certified by UL standard. **4.** Do not connect a ferrule for the applicable wires (AWG17 to AWG16/1.25 mm[2] to 1.5 mm[2] ) with an adjacent terminal insertion hole. **13** **G6D-F4PU/G3DZ-F4PU/G6D-F4B/G3DZ-F4B** ## **2. Removing Wires from the Push-In Plus Terminal** Use the following procedure to remove wires from the terminal. The same method is used to remove stranded wires, solid wires, and ferrules. **1.** Hold a flat-blade screwdriver at an angle and insert it into the release hole. **2.** With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. **3.** Remove the flat-blade screwdriver from the release hole. **==> picture [161 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> Flat-blade screwdriver<br>(1) (3)<br>(3) (1)<br>10° to 15°<br>(2) (2)<br>Wire<br>**----- End of picture text -----**<br> ## **Recommended Flat-blade Screwdriver** Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. ## � **Relay Replacement** - Use the Relay Removal Tool provided with the Unit to dismount a Terminal Relay. - Always turn OFF the power supply before replacing Relays. - When mounting Relays, take care to vertically insert the sockets of relays into the contact pins properly. - Relays with other models or other voltages cannot be mounted together. **==> picture [40 x 32] intentionally omitted <==** The following table shows manufacturers and models as of 2018/Dec. **==> picture [127 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Side Front<br>2.5 mm dia.<br>0.4 mm 2.5 mm<br>**----- End of picture text -----**<br> |Model|Manufacturer| |---|---| |ESD 0,40×2,5|Wera| |SZS 0,4×2,5<br>SZF 0-0,4×2,5*|Phoenix Contact| |0.4×2.5×75 302|Wiha| |AEF.2,5×75|Facom| |210-719|Wago| |SDIS 0.4×2.5×75|Weidmuller| |9900 (-2.5 × 75)|Vessel| - OMRON’s exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4×2,5 (manufactured by Phoenix Contact). **==> picture [57 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Example: G6D-F4PU<br>**----- End of picture text -----**<br> ## � **Removing the Terminal Cover (G6D-F4B)** Hold the base side of the terminal cover as shown in the diagram, and remove the terminal cover by pulling it in upward. **==> picture [80 x 52] intentionally omitted <==** ## � **Mountable Relays** Relays and SSRs cannot be mounted together. **14** ## **Terms and Conditions Agreement** ## **Read and understand this catalog.** Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## **Warranties.** (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## **Limitation on Liability; Etc.** OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## **Suitability of Use.** Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## **Programmable Products.** Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## **Performance Data.** Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## **Change in Specifications.** Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## **Errors and Omissions.** Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. **OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN** **Contact: www.ia.omron.com** _**Regional Headquarters**_ **OMRON EUROPE B.V.** Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 **OMRON ASIA PACIFIC PTE. LTD.** No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 **OMRON ELECTRONICS LLC** 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 © OMRON Corporation 2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. J228-E1-01** **OMRON (CHINA) CO., LTD.** Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China CSM_1_1_0319 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 0319(0319)
Updated at February 9, 2023
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →