G2RV-SL700-AC110
RELAY, SPDT, 250VAC, 30VDC, 6A
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Power Relays
- Contact; RELAY, SPDT, 250VAC, 30VDC, 6A; Contact Configuration:SPDT; Coil Voltage:110VAC; Contact Current:6A; Product Range:G2RV Series; Relay Mounting:Socket; Coil Type:Non Latching; Cont
- SVHC: No SVHC (17-Dec-2014)
- Coil Type: Non Latching
- Coil Voltage: 110VAC
- Product Range: G2RV Series
- Relay Mounting: Socket
- Coil Resistance: -
- Contact Current: 6A
- Relay Terminals: Quick Connect
- Contact Material: Silver Tin Indium
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: 30VDC
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 18.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Slim Relay G2RV** ## **The only truly industrial 6 mm relay** **==> picture [70 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Test switch type<br>**----- End of picture text -----**<br> **==> picture [83 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> No test switch type<br>**----- End of picture text -----**<br> - Lockable test switch models now available. - Large plug-in terminals for reliable connection. - LED indicator and mechanical flag for status indication. - Input type with gold plated contacts available. - Transparent housing allows inspection of contact condition. - Slim width to save space. - Push-in terminals and accessories for easy wiring. - Lloyd’s approval **==> picture [200 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> LR<br>PATENTED<br>**----- End of picture text -----**<br> ## **Features** ## ■ **Test switch operation** **==> picture [493 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> Protection cover: lock Protection cover: unlock<br>v ry<br>Protection cover open<br>it |< |<br>Protection cover close<br>a — ><br>|omron | = ee |omron ' =<br>Contact normal position Contact operated position<br>(ON state)<br>**----- End of picture text -----**<br> ## **OMRON Lockable test switch can be used in this way:** When the protection cover (located directly over the test switch) is closed, the test switch is retained in normal position (OFF state) by the protection cover. After opening the protection cover, the test switch can be unlocked. The test switch can then be moved to the operated position (ON state). After using the test switch, move it to the normal position (OFF state) and close the protection cover to prevent unwanted operation of the test switch. * Please check Precautions (Page. 17 : Precaution of test switch operation) when using test switch. ## **Application of test switch:** Example: Checking operation of Relays and sequence circuits. Slim Relay **G2RV** 1 ## **Model Number Structure** ## ■ **Model Number Legend** **G2RV-SL** @ @ @ **-** @ **-** @ **1 2 3 4 5 6** ## **1. Auxiliary Type Designation** SL: Slim relay and socket combination **2. Wire Connection** - 7: Screw terminals - 5: Push-in terminals **3. Relay LED** - 0: Without LED ## **4. Relay Test switch** - 0: No test switch type - 1: Test switch type **5. Contact form** - AP: Input type Blank: Standard type **6. Input Voltage** **Note:** LED indicator available on socket. ## **Orderin Information g** ## ■ **List of Models** |■**List of Models**|■**List of Models**||||||| |---|---|---|---|---|---|---|---| |**Classification**||**Enclosure**<br>**rating**|**Input**<br>**voltage**|**Type of**<br>**connection**|**Test**<br>**switch**|**Contact form (SPDT)**|| |||||||**Standard type**|**Input type**| |Plug-in terminals|General-purpose|Unsealed|AC/DC|Screw terminals|No|G2RV-SL700|G2RV-SL700-AP| ||||||Yes|G2RV-SL701|---| |||||Push-in terminals|No|G2RV-SL500|G2RV-SL500-AP| ||||||Yes|G2RV-SL501|---| ## **Relay and Socket Combinations** ## **No test switch type** |**Input voltage**|**Contact form (SPDT)**|**Contact form (SPDT)**|**Contact form (SPDT)**|**Contact form (SPDT)**| |---|---|---|---|---| ||**Standard type (No test switch type)**||**Input type (No test switch type)**|| ||**Screw terminals**|**Push-in terminals**|**Screw terminals**|**Push-in terminals**| |12 VDC|G2RV-SL700 12 VDC|G2RV-SL500 12 VDC|G2RV-SL700-AP 12 VDC|G2RV-SL500-AP 12 VDC| |24 VDC|G2RV-SL700 24 VDC|G2RV-SL500 24 VDC|G2RV-SL700-AP 24 VDC|G2RV-SL500-AP 24 VDC| |24 VAC/DC|G2RV-SL700 24 VAC/DC|G2RV-SL500 24 VAC/DC|G2RV-SL700-AP 24 VAC/DC|G2RV-SL500-AP 24 VAC/DC| |48 VAC/DC|G2RV-SL700 48 VAC/DC|G2RV-SL500 48 VAC/DC|G2RV-SL700-AP 48 VAC/DC|G2RV-SL500-AP 48 VAC/DC| |110 VAC|G2RV-SL700 110 VAC|G2RV-SL500 110 VAC|G2RV-SL700-AP 110 VAC|G2RV-SL500-AP 110 VAC| |230 VAC|G2RV-SL700 230 VAC|G2RV-SL500 230 VAC|G2RV-SL700-AP 230 VAC|G2RV-SL500-AP 230 VAC| ## **Test switch type** |**Input voltage**|**Contact form (SPDT)**|**Contact form (SPDT)**|**Contact form (SPDT)**|**Contact form (SPDT)**| |---|---|---|---|---| ||**Standard type (Test switch type)**||**Input type (Test switch type)**|| ||**Screw terminals**|**Push-in terminals**|**Screw terminals**|**Push-in terminals**| |24 VDC|G2RV-SL701 24 VDC|G2RV-SL501 24 VDC|---|---| |24 VAC/DC|G2RV-SL701 24 VAC/DC|G2RV-SL501 24 VAC/DC|---|---| Slim Relay **G2RV** 2 ## **S ecifications p** ## ■ **Input Ratings** |**Rated voltage**|**Rated current*1**|**Rated current*1**|**Rated current*1**|**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Power consumption**|**Power consumption**|**Input voltage**| |---|---|---|---|---|---|---|---|---| ||**AC**||**DC**|**% of rated voltage**||**AC (VA)**<br>**Approx.**|**DC (mW)**<br>**Approx.**|**% of rated voltage**| ||**50 Hz**|**60 Hz**||||||| |12 VDC|---|---|27.2 mA|80%|10%|---|300 mW|±10%| |24 VDC|---|---|13.3 mA|||---|300 mW|| |24 VAC/DC|21.1 mA|22.5 mA|13.0 mA|||0.5 VA|300 mW|| |48 VAC/DC|8.5 mA|9.0 mA|5.2 mA|||0.4 VA|250 mW|| |110 VAC|7.1 mA|7.5 mA|---|||0.8 VA|---|| |230 VAC|7.3 mA|7.9 mA|---|||1.7 VA|---|| *1)Rated currents are measured at 23 degrees Celsius (ambient) ## ■ **Contact Ratings** |**Item**|**Standard type (G2RV-SL700, 500, 701, 501)**|**Standard type (G2RV-SL700, 500, 701, 501)**|**Input type (G2RV-SL700-AP, 500-AP)*2**| |---|---|---|---| |**Number of poles**|1 pole||| |**Load**|Resistive load<br>(cosφ= 1)|Inductive load<br>(cosφ= 0.4, L/R = 7 ms)|Resistive load<br>(cosφ= 1)| |**Rated load**|6 A at 250 VAC;<br>6 A at 30 VDC|2.5 A at 250 VAC;<br>2 A at 30 VDC|50 mA at 30 VAC;<br>50 mA at 36 VDC| |**Rated carry current**|6 A||50 mA| |**Max. switching voltage**|400 VAC, 125 VDC||30 VAC, 36 VDC| |**Max. switching current**|6 A||50 mA| |**Max. switching power**|1,500 VA<br>180 W|500 VA<br>60 W|——| |**Failure rate (reference value)*1**|10 mA at 5 VDC (P level)||1 mA at 100 mVDC (P level)| |*1) P level:λ60= 0.1 × 10-6/operation<br>*2) If a gold layer is destroyed, contact ratings of standard type are applicable.<br>■**Characteristics**|||| |**Item**|**Standard type (G2RV-SL700, 500, 701, 501)**||**Input type (G2RV-SL700-AP, 500-AP)**| |**Contact resistance**|100 mΩmax.||| |**Operate (set) time**|20 ms max.||| |**Release time**|40 ms max.||| |**Max. operating frequency**|Mechanical: 18,000 operations/hr<br>Electrical: 1,800 operations/hr (under rated load)||| |**Insulation resistance**|1,000 MΩmin. (at 500 VDC)||| |**Dielectric strength**|4,000 VAC, 50/60 Hz for 1 min between coil and contacts*;<br>1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity||| |**Vibration resistance**|Destruction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)<br>Malfunction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)||| |**Shock resistance**|Destruction: 1,000 m/s2<br>Malfunction: 200 m/s2when energized; 100 m/s2when not energized||| |**Endurance**|Mechanical: 5,000,000 operations min.<br>Electrical: 100,000 Typical;<br>NO 70,000 operations min. ;<br>NC 50,000 operations min.||Mechanical: 5,000,000 operations min.<br>Electrical: 5,000,000 operations min.| |**Ambient temperature**|Operating: –40°C to 55°C (with no icingor condensation)||| |**Ambient humidity**|Operating: 5% to 85%||| |**Weight**|Approx. 35g||| |**Overvoltage category**|III||| |**Pollution degree**|2||| |**Contact material**|AgSnIn||AgSnIn + Gold Plating| |**Creepage distance**|7.0 mm||| |**Clearance distance**|5.5 mm||| **Note:** Values in the above table are the initial values. Slim Relay **G2RV** 3 ## ■ **Approved Standards** ## **UL 508 (File No. E41643)** |**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Operations**| |---|---|---|---|---| |G2RV-SL Series|SPDT|12 to 48 VDC<br>24 to 230 VAC|250 VAC 6 A (Resistive Load)<br>30 VDC 6 A (Resistive Load)<br>400 VAC 2 A (Resistive Load)|6,000| ## **IEC/VDE (EN 61810)** |**Contact form**|**Coil ratings**|**Contact ratings**|**Operations**| |---|---|---|---| |SPDT|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|250 VAC 6 A (Resistive Load)<br>30 VDC 6 A (Resistive Load)<br>400 VAC 2 A (Resistive Load)|50,000<br>50,000<br>6,000| ## **Lloyd's (File No. 07/10027 (E2))** |**Model**|**Contact form**|**Coil ratings**|**Contact ratings**| |---|---|---|---| |G2RV-SL Series|SPDT|12, 24 VDC<br>24, 48 VAC/DC<br>110, 230 VAC|250 VAC 6 A (Resistive load)<br>250 VAC 2.5 A (PF0.4)<br>30 VDC 6 A (Resistive load)<br>30 VDC 2 A (L/R=7ms)| ## **En ineerin Data g g** ## ■ **Endurance** ## **Switching capacity of DC resistive load** **==> picture [509 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 1000 10,0<br>30VDC resistive load<br>250VAC resistive load<br>1,0<br>100<br>30VDC inductive load<br>(L/R=7ms) 250VAC inductive load<br>(cos ϕ = 0.4)<br>0,1<br>10 20 60 100 140 180 220<br>0 2 4 6 Switching voltage (VDC)<br>Switching current (A)<br>3 operations)<br>DC Breaking Current (A)<br>Endurance (× 10<br>**----- End of picture text -----**<br> ## **Typical Operating and Release Time** |**Model number**|**Operating time (typical)**|**Release time (typical)**| |---|---|---| |G2RV-SL7@@/5@@DC12|5 ~ 7 ms|5 ~ 8 ms| |G2RV-SL7@@/5@@DC24|5 ~ 7 ms|6 ~ 9 ms| |G2RV-SL7@@/5@@AC/DC24|5 ~ 7 ms|17 ~ 22 ms| |G2RV-SL7@@/5@@AC/DC48|5 ~ 7 ms|22 ~ 30 ms| |G2RV-SL7@@/5@@AC110|12 ~ 15 ms|22 ~ 30 ms| |G2RV-SL7@@/5@@AC230|12 ~ 15 ms|22 ~ 30 ms| Slim Relay **G2RV** 4 ## **Accessories** ## ■ **PLC Interface P2RVC-8-** @ **-F** **Contact form Relay PLC Interface** Standard type G2RV-SL70@ series P2RVC-8-O-F Input type G2RV-SL700-AP series P2RVC-8-I-F ## **P2RVC-8-O-F (for G2RV-SL70** @ **series only)** ## **List of Models** |**Model number**|**Description**|**Connection**| |---|---|---| |P2RVC-8-O-F|PLC Output Interface for 8x<br>G2RV-SL70@-series<br>PNP - type|Ribbon cable connector<br>10 Pole, IEC603/1| ## **Specifications** ## **Electrical schematic P2RVC-8-O-F** |**Input**|**Rated voltage**|30 VAC/VDC max.| |---|---|---| ||**Current capacity**|0.5 A per channel| |||2.0 A total current, power supply<br>terminal| |**Characteristics**|**Ambient**<br>**temperature**|Operating: 0 to 55°C<br>Storage:<br>−20 to 85°C| ||**Overvoltage**<br>**category**|III| ||**Pollution degree**|2| ## **P2RVC-8-I-F (for G2RV-SL700-AP series only)** ## **List of Models** |**Model number**|**Description**|**Connection**| |---|---|---| |P2RVC-8-I-F|PLC Output Interface for 8x<br>G2RV-SL700-series<br>PNP - type|Ribbon cable connector<br>10 Pole, IEC603/1| ## **Specifications** |**Input**|**Rated voltage**|30 VAC/VDC max.| |---|---|---| ||**Current capacity**|0.5 A per channel| |||2.0 A total current, power supply<br>terminal| |**Characteristics**|**Ambient**<br>**temperature**|Operating: 0 to 55°C<br>Storage:<br>−20 to 85°C| ||**Overvoltage**<br>**category**|III| ||**Pollution degree**|2| ## **Electrical schematic P2RVC-8-I-F** **==> picture [10 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> 11<br>12<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 5 ## ■ **Cables for PLC Interface P2RVC-8-** @ **-F** ## **Cables selection List** |■**Cables for PLC Interface P2RVC-8-**<br>**Cables selection List**|■**Cables for PLC Interface P2RVC-8-**<br>**Cables selection List**| |---|---| |**Output**|| |**Model number**|**To be used for(combined with P2RVC-8-O-F)**| |P2RV-4-100C|CJ1W-OD232/OD262| |P2RV-4-200C|CJ1W-OD232/OD262| |P2RV-4-300C|CJ1W-OD232/OD262| |P2RV-4-500C|CJ1W-OD232/OD262| |P2RV-A100C|Universal(stranded wires)| |P2RV-A200C|Universal(stranded wires)| |P2RV-A300C|Universal(stranded wires)| |P2RV-A500C|Universal(stranded wires)| |P2RV-A050C-OMR GRT1|GRT1-OD8(G)-1| |P2RV-A100C-OMR GRT1|GRT1-OD8(G)-1| |P2RV-A050C-OMR NX|NX-OD4256| |P2RV-A100C-OMR NX|NX-OD4256| |P2RV-200C-SIM S7/300|6ES7 322-1BL00-0AA0, 32DO| |P2RV-250C-SIM S7/300|6ES7 322-1BL00-0AA0,32DO| |P2RV-300C-SIM S7/300|6ES7 322-1BL00-0AA0, 32DO| |P2RV-500C-SIM S7/300|6ES7 322-1BL00-0AA0, 32DO| |P2RV-200C-SIM S7/400|6ES7422-1BL00-0AA0 & 6ES7422-7BL00-0AB0, 32DO| |P2RV-250C-SIM S7/400|6ES7422-1BL00-0AA0 & 6ES7422-7BL00-0AB0, 32DO| |P2RV-300C-SIM S7/400|6ES7422-1BL00-0AA0 & 6ES7422-7BL00-0AB0, 32DO| |P2RV-500C-SIM S7/400|6ES7422-1BL00-0AA0 & 6ES7422-7BL00-0AB0, 32DO| ||**Input**| |---|---| |**Model number**|**To be used for(combined with P2RVC-8-I-F)**| |P2RV-4-100IFC|CJ1W-ID231/ID233/ID261| |P2RV-4-100IMC|CJ1W-ID233/ID262| |P2RV-4-200IFC|CJ1W-ID231/ID233/ID261| |P2RV-4-200IMC|CJ1W-ID233/ID262| |P2RV-4-300IFC|CJ1W-ID231/ID233/ID261| |P2RV-4-300IMC|CJ1W-ID233/ID262| |P2RV-4-500IFC|CJ1W-ID231/ID233/ID261| |P2RV-4-500IMC|CJ1W-ID233/ID262| |P2RV-A100C|Universal(stranded wires)| |P2RV-A200C|Universal(stranded wires)| |P2RV-A300C|Universal(stranded wires)| |P2RV-A500C|Universal(stranded wires)| |P2RV-A050IC-OMR GRT1|GRT1-ID8-1| |P2RV-A100IC-OMR GRT1|GRT1-ID8-1| |P2RV-A050IC-OMR NX|NX-ID4442| |P2RV-A100IC-OMR NX|NX-ID4442| |P2RV-200C-SIM S7/300|6ES7 321-1BL00-0AA0, 32DI| |P2RV-250C-SIM S7/300|6ES7 321-1BL00-0AA0,32DI| |P2RV-300C-SIM S7/300|6ES7 321-1BL00-0AA0, 32DI| |P2RV-500C-SIM S7/300|6ES7 321-1BL00-0AA0, 32DI| |P2RV-200C-SIM S7/400|6ES7421-1BL00-0AA0 & 6ES7421-1BL01-0AA0, 32DI| |P2RV-250C-SIM S7/400|6ES7421-1BL00-0AA0 & 6ES7421-1BL01-0AA0, 32DI| |P2RV-300C-SIM S7/400|6ES7421-1BL00-0AA0 & 6ES7421-1BL01-0AA0, 32DI| |P2RV-500C-SIM S7/400|6ES7421-1BL00-0AA0 & 6ES7421-1BL01-0AA0, 32DI| ## **P2RV-4-** @@@ **C P2RV-4-** @@@ **IMC P2RV-4-** @@@ **IFC** Cable to connect CJ1 to 4 × P2RVC-8-@-F ## **List of Models** |**I/O**|**Model number**|**Cable length**|**Interface unit**|**PLC Connection**|**Connectors**| |---|---|---|---|---|---| |Output|P2RV-4-100C|1.0 m|P2RVC-8-O-F<br>× 4|OMRON PLC<br>CJ1 Series: MIL|MIL40 - MIL10<br>× 4| ||P2RV-4-200C|2.0 m|||| ||P2RV-4-300C|3.0 m|||| ||P2RV-4-500C|5.0 m|||| |Input|P2RV-4-100IMC|1.0 m|P2RVC-8-I-F<br>× 4|OMRON PLC<br>CJ1 Series: MIL|MIL40 - MIL10<br>× 4| ||P2RV-4-200IMC|2.0 m|||| ||P2RV-4-300IMC|3.0 m|||| ||P2RV-4-500IMC|5.0 m|||| |Input|P2RV-4-100IFC|1.0 m|P2RVC-8-I-F<br>× 4|OMRON PLC<br>CJ1 Series:<br>Fujitsu|FCN40 -MIL10<br>× 4| ||P2RV-4-200IFC|2.0 m|||| ||P2RV-4-300IFC|3.0 m|||| ||P2RV-4-500IFC|5.0 m|||| P2RV-4-@@@C/P2RV-4-@@@IMC **==> picture [511 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> 10 9 CN1 10 9 CN1<br><7] 120 19 CN2 <7] 102 19 CN2<br>1 2 B1 A1<br>2 1 2 1<br>10 9 CN3 10 9 CN3<br>39 40 (45) B20 A20<br>2 1 (45) 2 1<br>10 9 CN4 10 9 CN4<br>Cable length as indicated Cable length as indicated<br>D @@@by model number. = length in centimeters f (300) 2 a 1 by model number. @@@ = length in centimeters e (300) 2 1<br>P2RV-4-@@@C/P2RV-4-@@@IMC P2RV-4-@@@IFC<br>CN1 CN1<br>CN2 CN2<br>CN3 CN3<br>CN4 CN4<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 6 **4 × 10 pole IDC mounting to 4 × P2RVC-8-** @ **-F** **==> picture [510 x 457] intentionally omitted <==** **----- Start of picture text -----**<br> P2RV-4-@@@C CN1<br>CN1 CN2 CN3 CN4<br>1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 by model number.Cable length as indictad@@@ = length in centimeters CN2<br>CN3<br>Split into 4 sections<br>40 38 36 34 32 30 28 26 22 24 39 37 35 33 31 29 27 25 21 23 20 18 16 14 12 10 8 6 2 4 19 17 15 13 11 9 7 5 1 3 Length = 30 cm CN4<br>TT TTT ATT TT #@— < —<br>P2RV-4-@@@IMC<br>CN1 CN2 CN3 CN4<br>1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10<br>40 38 36 34 32 30 28 26 NC 24 39 37 35 33 31 29 27 25 NC 23 20 18 16 14 12 10 8 6 NC 4 19 17 15 13 11 9 7 5 NC 3<br>IIT AUT TAT TTT<br>P2RV-4-@@@IFC<br>CN1 CN2 CN3 CN4<br>1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10<br>A1 A2 A3 A4 A5 A6 A7 A8 NC A9 A10 A11 A12 A13 A14 A15 A16 A17 NC A18 B1 B2 B3 B4 B5 B6 B7 B8 NC B9 B10 B11 B12 B13 B14 B15 B16 B17 NC B18<br>HUTT HUT TAT TTT<br>40 pole IDC mounting to Omron PLC CJ1-OD232<br>Technical data<br>Control line AWG28/0.08 mm [2] , tin-plated copper<br>Diameter cable 10.7 mm (one end splits into 4 sections: A, B, C, D)<br>Operating voltage 60 VDC<br>Continuous current per signal wire 0.5 A<br>Max. total current, 4 bytes, each 1.0 A<br>Test voltage 0.5 KV, 50 Hz, 1 min<br>—S=> Operating temperature range -20°C to +50°C<br>P2RV-A @@@ C<br>Cable, single sided 10 pole IDC connector, to connect to P2RVC-8-@-F<br>40 Pole<br>**----- End of picture text -----**<br> **List of Models I/O Model number Cable length Interface unit PLC interface Connectors** Universal P2RV-A100C 1.0 m P2RVC-8-@-F - MIL10 - (Output/ P2RV-A200C 2.0 m No connector Input) P2RV-A300C 3.0 m P2RV-A500C 5.0 m ~~EEF FTI~~ 2O **==> picture [260 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2 1<br>10 9 (45)<br>10<br>Cable length as indicated (2)<br>by model number.<br>@@@ = length in centimeters (70) (10)<br>?P?R<br>?T<br>?V<br>?X<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 7 ## **10 pole IDC mounting to P2RVC-8-** @ **-F** > 10 e ~~e~~ b0€02C—C ~~a~~ GRAY / BLACK > 9 TF ~~S~~ s ~~f~~ GRAY / RED 8 ORANGE / BLACK > 7 e ~~o~~ ORANGE / RED 6 GREEN / BLACK > 5 v ~~0~~ 2 00—0—0—_ s ~~l~~ GREEN / RED > 4 -—T ~~TE~~ PINK / BLACK > 3 ———————-eeoe-————s.:a ~~2E~~ PINK / RED > 2 ~~a~~ 4 BLUE / BLACK 1 BLUE / RED **==> picture [95 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> Cable length as indictad<br>by model number.<br>@@@ = length in centimeters<br>Outer isolation removed<br>10 Pole<br>**----- End of picture text -----**<br> ## **Technical data** |**Technical data**|| |---|---| |**Control line**|AWG26/0.14 mm2, tin-plated copper| |**Diameter cable**|7.6 mm| |**Operating voltage**|60 VDC| |**Continuous currentper signal wire**|0.5 A| |**Max. total current**|1.0 A| |**Test voltage**|0.5 KV, 50 Hz, 1 min| |**Operating temperature range**|-20°C to +50°C| ## **P2RV-A** @@@ **C-OMR GRT1 P2RV-A** @@@ **IC-OMR GRT1** ## **List of Models** |**I/O**|**Model number**<br>**len**|**Cable**<br>**length**|**Cable**<br>**th**<br>**Interface unit**|**PLC interface**| |---|---|---|---|---| |Output|P2RV-A050C-OMR GRT1<br>0.5 m|0.5 m|P2RVC-8-O-F|OMRON Smart<br>slice I/O module<br>GRT1 Series<br>GRT1-OD8(G)-1| ||P2RV-A100C-OMR GRT1<br>1.0 m|1.0 m||| |Input|P2RV-A050IC-OMR GRT1<br>0.5 m|0.5 m|P2RVC-8-I-F|OMRON Smart<br>slice I/O module<br>GRT1 Series<br>GRT1-ID9(G)-1| ||P2RV-A100IC-OMR GRT1<br>1.0 m|1.0 m||| **==> picture [381 x 229] intentionally omitted <==** **----- Start of picture text -----**<br> A1<br>B1<br>2 1<br>f ooaq)- N o S S l s — A Z z q i Zs<br>10 9 (45) A6<br>Cable length as indicated B6<br>by model number. (45)<br>@@@ = length in centimeters<br>10 pole IDC mounting to P2RVC-8- @ -F<br>P2RV-A@@@C-OMR GRT1 P2RV-A@@@IC-OMR GRT1<br>1 X K A1 1 9 B6<br>2 e o B1 2 e o A6<br>3 X K A2 3 4 B4<br>4 e S B2 4 e o A4<br>5 D o A4 5 X K B3<br>6 > S B4 6 X K A3<br>7 e o A5 7 e o B1<br>8 X K B5 8 a 9 A1<br>9 NC 9 B2<br>10 B6 10 NC<br>?P?R<br>?T<br>?V<br>?X<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 8 ## **P2RV-A** @@@ **C-OMR NX P2RV-A** @@@ **IC-OMR NX** ## **List of Models** |**I/O**|**Model number**<br>**Cable**<br>**len**|**Cable**<br>**length**|**Interface unit**|**PLC interface**| |---|---|---|---|---| |Output|P2RV-A050C-OMR GRT1<br>0.5 m|0.5 m|P2RVC-8-O-F|OMRON I/O<br>module NX<br>Series| ||P2RV-A100C-OMR GRT1<br>1.0 m|1.0 m||| |Input|P2RV-A050IC-OMR GRT1<br>0.5 m|0.5 m|P2RVC-8-I-F|| ||P2RV-A100IC-OMR GRT1<br>1.0 m|1.0 m||| **==> picture [249 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> B1 A1<br>2 1<br>b l l e — = 5 as<br>10 9 (45)<br>Cable length as indicated = tS B6 IER A6<br>by model number. (45)<br>@@@ = length in centimeters<br>?P<br>?R<br>?T<br>?V<br>?X<br>**----- End of picture text -----**<br> ## **10 pole IDC mounting to P2RVC-8-** @ **-F** **==> picture [332 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> P2RV-A@@@C-OMR NX P2RV-A@@@IC-OMR NX<br>1 > A1 1 > B7<br>2 >> B1 2 A7<br>3 a A3 3 e s B5<br>4 o d B3 4 > A5<br>5 > A5 5 > B3<br>6 > B5 6 > A3<br>7 > A7 7 > B1<br>8 > B7 8 >— A1<br>9 NC 9 B8<br>10 —————— B8 10 detente eee e eee e eee eee eee eeeeeeeeeeeeeeeeeeeeeee e s NC<br>**----- End of picture text -----**<br> ## **P2RV-** @@@ **C-SIM S7/** @ **00** Cables to connect Siemens S7/300 or S7/400 to 4 × P2RVC-8-@-F ## **List of Models** |**List of Models**||| |---|---|---| |**Model number**|**Cable length**|**PLC type**| |P2RV-200C-SIM S7/300|2.0 m|Siemens S7/300<br>4x1 Byte| |P2RV-250C-SIM S7/300|2.5 m|| |P2RV-300C-SIM S7/300|3.0 m|| |P2RV-500C-SIM S7/300|5.0 m|| |P2RV-200C-SIM S7/400|2.0 m|Siemens S7/400<br>4x1 Byte| |P2RV-250C-SIM S7/400|2.5 m|| |P2RV-300C-SIM S7/400|3.0 m|| |P2RV-500C-SIM S7/400|5.0 m|| Slim Relay **G2RV** 9 ## ■ **Single Relays for Maintenance** ## **Model Number Legend** **G2RV-** @ **-** @ @ @ **-** @ **-** @ **1 2 3 4 5 6** ## **1. Number of Poles** - 1: 1 pole ## **2. Terminals** - S: Plug-In ## **3. Relay LED** Blank: Without LED ## **4. Relay Test switch** Blank: No test switch - I: Test switch ## **5. Contact Material** Blank: AgSnIn - AP: AgSnIn hard gold-plated ## **6. Rated Coil Voltage** 11 VDC, 21 VDC, 48 VDC ## **List of Models** ## **G2RV-1-SI** ## **G2RV-1-S** |**Model number**|**Replacement for**| |---|---| |G2RV-1-S 11 VDC|G2RV-SL700/500 12 VDC| |G2RV-1-S 21 VDC|G2RV-SL700/500 24 VDC| ||G2RV-SL700/500 24 VAC/DC| |G2RV-1-S 48 VDC|G2RV-SL700/500 48 VAC/DC| ||G2RV-SL700/500 110 VAC| ||G2RV-SL700/500 230 VAC| |G2RV-1-S-AP 11 VDC|G2RV-SL700/500-AP 12 VDC| |G2RV-1-S-AP 21 VDC|G2RV-SL700/500-AP 24 VDC| ||G2RV-SL700/500-AP 24 VAC/DC| |G2RV-1-S-AP 48 VDC|G2RV-SL700/500-AP 48 VAC/DC| ||G2RV-SL700/500-AP 110 VAC| ||G2RV-SL700/500-AP 230 VAC| |G2RV-1-SI 21 VDC|G2RV-SL701/501 24 VDC| ||G2RV-SL701/501 24 VAC/DC| ## ■ **Cross bars** ## **Model Number Legend** **P2RVM -** @ @ **1 2** **2. Color** ## **1. Number of Poles** 020: 2 poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black < 100: 10 poles \. 200: 20 poles **List of Models Specification Model number Poles Color** Max current 32 A P2RVM-020@ 2 (EN60947-7-1 section 8.3.3 / 1991) P2RVM-030@ 3 Red (R) Max. Voltage 400 VAC P2RVM-040@ 4 Blue (S) Max. Voltage 250 VAC P2RVM-100@ 10 Black (B) when cutting Cross-bar without using separation P2RVM-200@ 20 ~~=~~ plate or end-bracket ~~==5~~ @ select color: R = Red, S=Blue, B=Black ■ **Plastic Labels for G2RV Sockets Model number Box quantity Color** R99-15 for G2RV 1 piece = 1 sheet = 120 labels White ~~[_ 1~~ Slim Relay **G2RV** 10 ## ■ **Labels (Stickers) for G2RV Sockets** |**Model number**|**Box quantity**|**Color**| |---|---|---| |R99-16 for G2RV|1 piece = 1 sheet = 484 labels<br>(stickers)|White| ## ■ **Separating Plates** |**Model number**|**Description**| |---|---| |P2RV-S|Provides isolation between adjacent relays to<br>achieve 400 V isolation.| Slim Relay **G2RV** 11 ## **Dimensions** **Note:** All units are in millimeters unless otherwise indicated. ## **Complete Unit** **G2RV-SL700 G2RV-SL700-AP** **==> picture [422 x 330] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement<br>Input circuit<br>12<br>11<br>14<br>106.7 max.<br>12<br>83<br>70.9 A2 11<br>47.2 A1 14<br>6.2 max. 26.1<br>24 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>12<br>A2<br>11<br>35 A1<br>14<br>92.7 max.<br>Other Coil Voltage<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>A2<br>Five, 88.9 7.1<br>M2.5 × 6 99.2 A1<br>12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br> ## **G2RV-SL701** **==> picture [429 x 333] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement<br>Input circuit<br>12<br>11<br>14<br>109.7 max.<br>12<br>83<br>A2 11<br>70.9<br>47.2 A1 14<br>6.2 max. 26.1<br>24 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>12<br>A2<br>11<br>35 92.7 max. 14 A1<br>Other Coil Voltage<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>Five, 88.9 A2<br>M2.5 × 6 102.2 7.1<br>A1<br>12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 12 **G2RV-SL500 G2RV-SL500-AP** **Dimensions** **==> picture [97 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Arrangement<br>**----- End of picture text -----**<br> **==> picture [426 x 314] intentionally omitted <==** **----- Start of picture text -----**<br> Input circuit<br>12<br>11<br>14<br>106.7 max.<br>12<br>82.9<br>69.8 A2 11<br>46 A1 14<br>6.2 max. 24.6<br>24 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>12<br>A2<br>11<br>35 97.4 max. 14 A1<br>Other Coil Voltage<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>A2<br>88.9 7.1<br>A1<br>99.2<br>12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br> **==> picture [202 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> G2RV-SL501 Dimensions<br>**----- End of picture text -----**<br> **==> picture [432 x 331] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement<br>Input circuit<br>12<br>11<br>14<br>109.7 max.<br>12<br>82.9<br>69.8 A2 11<br>6.2 max. 46<br>A1 14<br>24.6<br>24 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>12<br>A2<br>11<br>35 97.4 max. 14 A1<br>Other Coil Voltage<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>88.9 A2<br>102.2 7.1<br>A1<br>12 V DC<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 13 ## **Single Relay** ## **G2RV-1-S G2RV-1-S-AP** **==> picture [227 x 201] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2 max. 30.5 max.<br>33 max.<br>16.2<br>1.8 0.5 2.4<br>3.5<br>5.04 5.04<br>22 3<br>**----- End of picture text -----**<br> **==> picture [64 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> Input circuit<br>14 11 12 A1 A2<br>Terminal Arrangement/<br>Internal Connections<br>(Bottom View)<br>**----- End of picture text -----**<br> ## **G2RV-1-SI** **==> picture [239 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2 max. 30.5 max.<br>36 max.<br>16.2<br>1.8 0.5<br>2.4<br>3.5<br>5.04<br>22 3<br>5.04<br>**----- End of picture text -----**<br> **==> picture [64 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Input circuit<br>14 11 12 A1 A2<br>Terminal Arrangement/<br>Internal Connections<br>(Bottom View)<br>**----- End of picture text -----**<br> Slim Relay **G2RV** 14 **Installation** ## ■ **Tools** G2RV-SL70@ series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G2RV-SL50@ series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. ## **Applicable Screwdriver** - Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) - Flat-blade, Parallel-tip 2.5 dia. (3.0 mm max.) ● Flat-blade, Flared-tip ## **Cannot be used.** Examples: FACOM AEF.2.5×75E (AEF. 3×75E) VESSEL No. 9900-(-)2.5×75 (No. 9900-(-)3×100) WAGO 210-119 WIHA 260/2.5×40 (260/3×50) - *Chamfering the tip of the driver improves insertion when used as an exclusive tool. ## **P2RVC-8-O-F (for G2RV-SL70** @ **series only)** ## **List of Models** |**Model number**|**Description**|**Connection**| |---|---|---| |P2RVC-8-O-F|PLC Output Interface for 8x<br>G2RV-SL70@-series<br>PNP - type|Ribbon cable connector<br>10 Pole, IEC603/1| ## ■ **Applicable Wires** ## **Applicable Wire Sizes** ## **G2RV-SL700 Series** ## **Box clamp technology** |**Box clamp technology**||| |---|---|---| |**Wire type**|**Applicable wire size**|**Stripping length**| |Stranded without ferrules|0.5 - 2.5 mm2|7 mm| |Stranded with ferrules and plastic collar|0.5 - 2.5 mm2|7 mm| |Stranded with ferrules without plastic collar|0.5 - 2.5 mm2|7 mm| |Solid|0.5 - 2.5 mm2|7 mm| ## **G2RV-SL500 Series** ## **Push-in technology** |**Push-in technology**||| |---|---|---| |**Wire type**|**Applicable wire size**|**Stripping length**| |Stranded without ferrules|0.5 - 2.5 mm2|12 mm| |Stranded with ferrules and plastic collar|0.5 - 2.5 mm2|12 mm| |Stranded with ferrules without plastic collar|0.5 - 2.5 mm2|12 mm| |Solid|0.5 - 2.5 mm2|12 mm| Slim Relay **G2RV** 15 ## ■ **Wiring** Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G2RV-SL700 series, 12 mm for a G2RV-SL500 series. **==> picture [172 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> G2RV-SL700<br>7 mm<br>G2RV-SL500<br>12 mm<br>Fig. 1 Exposed Conductor Length<br>**----- End of picture text -----**<br> ## **- Wiring Procedure for G2RV SL500 series** **==> picture [75 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> Screwdriver hole<br>Wire connection hole<br>**----- End of picture text -----**<br> ● **Wiring** **==> picture [69 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> ● Removing<br>**----- End of picture text -----**<br> Wire (2 ~~. Le~~ Insert the specified screwdriver into the release hole. Insert the exposed conductor into the connection hole. No other tools are required. Removing wire. **Note:** In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire. Removing screwdriver. Slim Relay **G2RV** 16 **Precautions** ## **Precautions for Connection** - Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. - Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. - Do not pour water or cleansing agents on the product. Doing so may result in electric shock. - Do not use the socket in locations subject to solvents or alkaline chemicals. - Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. - Do not dispose the product in fire. ## **Removing from Mounting Rail** To remove the socket from the mounting rail, insert the tip of D screwdriver in the fixture rail, and move it in the direction shown ~~7~~ below. ~~D~~ - Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. ## **Precaution for Operation of Test switch** ## ■ **Tool: G2RV-SL701/501 series: 2.5 mm width Flat-Blade screwdriver should be used for operation of test switch.** **•** Insert the screwdriver along the hole wall as shown below. — Screwdriver - If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. - Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. ## **General Precautions** - Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. - Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. - Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. - Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) > ● Flat-blade, Parallel-tip oo, i) 2.5 dia. (3.0 mm max.) ● Flat-blade, Flared-tip **Cannot be used.** ## ■ **Cautions:** - When you operate a test switch, please turn off electrical power supply. - After you have finished to operate a test switch, return the test switch to its original state - Do not use test switch as a switch. - Durability of test switch operation is more than 100 times. - Please avoid to use the latching lever by ON state with carry current in long time, more than 24 hours to maintain the initial performance for operation checking. ## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.** To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J11E-EN-07 **In the interest of product improvement, specifications are subject to change without notice.** Slim Relay **G2RV** 17
Updated at June 7, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →