Image not available
Illustrative purposes only
G2RL-1A-E2-CV-HA DC12
POWER RELAY, SPST-NO, 12VDC, 23A, TH
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON ELECTRONIC COMPONENTS
- Product type: Power Relays
- Contact Configuration:SPST-NO; Coil Voltage:12VDC; Contact Current:23A; Product Range:G2RL Series; Relay Mounting:Through Hole; Coil Type:-; Contact Voltage VAC:2 02AH4160
- Coil Type: -
- Coil Voltage: 12VDC
- Product Range: G2RL Series
- Relay Mounting: Through Hole
- Coil Resistance: 360ohm
- Contact Current: 23A
- Relay Terminals: Solder
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 3.04 € |
| Current stock | 50+ |
| Lead time | 30 days |
## G2RL-1A-E2-CV-HA **PCB Power Relay** - **Compact single pole Relay for High Current Load Switching &** - **G 2 R High Ambient Temperature L I • High current 23 A switching surpassing standard G2RL models. E2 • Meets ambient operating temperature requirements of 105°C • Low profile; 16.7 mm max. in height.** - **G • Reinforced insulation between coil and contact with 10 kV Impulse voltage. 2 R • Conforms to EN60335-1 of Safety of Household appliances. L • Clearance and creepage distances: 8 mm / 8 mm min. I • Coil insulation system: Class F (UL1446)** - **1 A** ~~[~~ **RoHS Compliant** - **I E 2 Model Number Legend I C V G2RL-** @ @ @ **-** @ **-** @ **-** @ **I 1 2 3 4 5 6 H A 1. Number of pole 4. Classification** 1: 1 Pole E2: High-capacity at 23 A **2. Contact Form 5. Special Requirement** A: SPST-NO (1a) CV: Ambient operating temperature 105°C **3. Enclosure Rating 6. Market Code** None: Flux protection HA: Home Appliance according to IEC/EN60335-1 ## **Application Examples** - **Home appliances • Cooking top, Microwave Oven • Industrial use** - **HVAC** ## **Ordering Information** |**Classification**<br>**Contact form**<br>**Enclosure rating**|**Model**|**Rated coil voltage**|**Minimum packing unit**| |---|---|---|---| |High-capacity &<br>High-temperature<br>SPST-NO (1a)<br>Flux protection|**G2RL-1A-E2-CV-HA**|5 VDC<br>12 VDC<br>24 VDC|100 pcs. / tray| |**Note: 1.**When ordering, add the rated coil voltage to the model number.|||| |Example: G2RL-1A-E2-CV-HA DC5|||| |However, the notation of the coil voltage on the product case will be marked as@@VDC.<br>Rated coil voltage<br>~~“L_~~|||| |**Note: 2.**Place your order in tray (100 pcs./tray) units.|||| ## **Ratings** ## ● **Coil Ratings** |**Item**<br>**Rated voltage**|**Rated current**<br>**(mA)**|**Coil resistance**<br>**(**Ω**)**|**Must-operate voltage**<br>**(V)**|**Must-release voltage**<br>**(V)**|**Max. voltage (V)**|**Power consumption**<br>**(mW)**| |---|---|---|---|---|---|---| ||||**% of rated voltage**|||| |**5 VDC**|80.0|62.5|75% max.|10% min.|130%<br>(at 23°C)|Approx. 400| |**12 VDC**|33.3|360||||| |**24 VDC**|16.7|1,440||||| **Note: 1.** The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. **Note: 2.** The operating characteristics are measured at a coil temperature of 23°C. **Note: 3.** The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ## ● **Contact** |**Classification**<br>**Item**<br>**Model**|**High-capacity & High-temperature type (resistive load)**| |---|---| ||**G2RL-1A-E2-CV-HA**| |**Contact type**|Single| |**Contact material**|Ag-Alloy (Cd free)| |**Rated load**|23 A at 250 VAC| |**Rated carry current**|23 A| |**Max. switching voltage**|250 VAC| |**Max. switching current**|23 A| **1** G2RL-1A-E2-CV-HA **PCB Power Relay** **G 2 R L I E 2** **G 2 R L I 1 A I E 2 I C V I H A** ## **Characteristics** |**Classification**|**Classification**|**High-capacity & High-temperature type**| |---|---|---| |**Item**<br>**Model**||**G2RL-1A-E2-CV-HA**| |**Contact resistance*1**||100 mΩmax.| |**Operate time**||15 ms max.| |**Release time**||5 ms max.| |**Insulation resistance*2**||1,000 MΩmin.| |**Dielectric strength**|**Between coil and contacts**|5,000 VAC, 50/60 Hz for 1 min| ||**Between contacts of the**<br>**same polarity**|1,000 VAC, 50/60 Hz for 1 min| |**Impulse withstand voltage**||10 kV (1.2 × 50 µs)| |**Vibration resistance**|**Destruction**|10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)| ||**Malfunction**|10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)| |**Shock resistance**|**Destruction**|1,000 m/s2| ||**Malfunction**|Energized: 100 m/s2, De-energized: 100 m/s2| |**Durability**|**Mechanical**|20,000,000 operations (18,000 operation per hour)| ||**Electrical*3**<br>**(resistive load)**|100,000 operations at 250 VAC, 23 A, at 105°C (1s ON / 9s OFF)| |**Ambient operating temperature**||-40°C to 105°C (with no icing or condensation)| |**Ambient operating humidity**||5% to 85% (with no icing or condensation)| |**Weight**||Approx. 12 g| **Note:** Values in the above table are the initial values at 23°C. - *1. Measurement conditions: 5 VDC, 1 A, voltage drop method - *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 360 operations per hour. ## **Engineering Data** ## ● **Maximum Switching Capacity** **==> picture [149 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> 25<br>23<br>20<br>15<br>10<br>5<br>0<br>0 50 100 150 200 250 300<br>Switching voltage (V)<br>Switching current (A)<br>**----- End of picture text -----**<br> ## ● **Ambient Temperature vs. Maximum Coil Voltage** **==> picture [155 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> 200<br>180<br>150<br>130<br>100<br>50<br>0<br>0 20 23 40 60 80 100 105 120<br>Ambient Temperature (°C)<br>Maximum coil voltage (% of rated)<br>**----- End of picture text -----**<br> **Note:** The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. ## ● **Shock Malfunction** ## ● **Ambient Temperature vs. Must Operate and Must Release Voltage** **==> picture [429 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> Y 1,000 Test conditions: Shock is applied 100 Must operate voltage<br>in ±X, ±Y, and ±Z directions three 90 Must release voltage<br>times each with without energizing 80 max.<br>X' Z the Relays to check the number of 70 X<br>1,000 1,000 malfunctions. min.<br>Requirement: None malfuction 60<br>100 m/s [2] 50 max.<br>130 40 min.X<br>30<br>1,000 1,000 Shock direction 20<br>Z' X X X' 10<br>Y<br>0<br>Z 0 20 40 60 80 100 120<br>Z' Ambient Temperature (°C)<br>Y'1,000 Unit: m/s [2] Y'<br>Maximum coil voltage (% of rated)<br>**----- End of picture text -----**<br> **2** G2RL-1A-E2-CV-HA **PCB Power Relay** **(Unit: mm)** **G 2 R L I E 2** **G 2 R L I 1 A I E 2 I C V I H A** ## **Dimensions** ## **G2RL-1A-E2-CV-HA** **==> picture [413 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Mounting Holes Terminal Arrangement/<br>(Bottom View) Internal Connections<br>12.7 max. 5 Six, 1.3-dia. holes (Bottom View)<br>29 max.(28.8)* (12.5)* (2.5) 1 3 4<br>7.5<br>16.7 max.<br>(16.5)* 8 6 5<br>(2.3) 20 (No coil polarity)<br>3.5 0. 5 0.5 0.8<br>0.5<br>* Average value<br>**----- End of picture text -----**<br> ## **Approved Standards** **UL Recognized: (File No. E41643)** **CSA Certified: (File No. LR31928)** |**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |---|---|---|---|---| |G2RL-1A-E2-CV-HA|SPST-NO (1a)|5 to 24 V|23 A, 250 VAC (Resistive) 105°C|100,000| |**EN/IEC, TÜV:**<br>**(Certisfied/No.*****)**||||| |**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |G2RL-1A-E2-CV-HA|SPST-NO (1a)|5 to 24 V|23 A, 250 VAC (cosφ=1) 105°C|100,000| |||||| |**Creepage distance**||8 mm min.||| |**Clearance distance**||8 mm min.||| |**Insulation material group**||IIIa||| |**Type of insulation coil-contact**<br>**open contact circuit**||Reinforced<br>Micro disconnection||| |**Rated insulation voltage**||250 V||| |**Pollution degree**||3||| |**Rated voltage system**||250 V||| |**Over voltage category**||III||| |**Category of protection according to IEC61810-1**||RTII (flux protection)||| |**Glow wire according to IEC 60335-1**||GWT 750°C min. (IEC 60695-2-11/GWFI 850°C min (IEC 60695-2-12)||| |**Tracking Index of relay base**||PTI 250 V min. (housing parts)||| |**Flammability class according to UL94**||V-0||| |**Coil Insulation system**||F Class (UL 1446)||| ## **Precautions** ## ● **Please refer to** _**PCB Relays Common Precautions**_ **for correct use.** ## **Electrical Appliance and Material Safety Law (Japan)** The G2RL-1A-E2 series is not compliant with the Electrical Appliance and Material Safety Law of Japan. Please pay careful attention to select a suitable relay for the application. - Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. - Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. ## **OMRON Corporation** ## **Electronic and Mechanical Components Company** ## **Regional Contact** **Americas Europe** https://www.components.omron.com/ http://components.omron.eu/ **Asia-Pacific China** https://ecb.omron.com.sg/ https://www.ecb.omron.com.cn/ **Korea Japan** https://www.omron-ecb.co.kr/ https://www.omron.co.jp/ecb/ © OMRON Corporation 2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. K315-E1-01** 1218(1218)(O) **3**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →