G05R
High Voltage DC/DC Converter, Proportional, Positive Output, Adjustable, 1.5 W, 3 mA
- Manufacturer: XP POWER
- Product type:
- SVHC: No SVHC (15-Jan-2018)
- Polarity: Positive Output
- Power Rating: 1.5W
- Product Range: G Series
- Output Current Max: 3mA
- Output Voltage Max: 500V
- Output Voltage Min: 0V
- Input Voltage DC Max: 12V
- Input Voltage DC Min: 700mV
- Power Supply Mounting: Through Hole
- DC / DC Converter Output Type: Adjustable
- High Voltage Power Supply Type: Proportional
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 112.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
## G Series ## 1.5W **CONVECTION COOLED** ## DC-HVDC CONVERTER The G Series is a line of miniature high voltage converters that provide up to 6kV output, positive or negative, in a compact PCB mount package. The isolated output is directly proportional to the input, and is linear from approximately 0.7 volts in. Excellent filtering techniques and a low noise quasi-sinewave oscillator provide clean, reliable DC to HV DC conversion with low ripple and low EMI/RFI. The isolated output allows for user selectable output polarity. When the optional center-tap pin is grounded, the unit provides both positive and negative outputs from one compact, low cost module. The pin pattern used on this model has become an industry standard for high voltage modules. The G Series units are component level converters that are easy to integrate, low cost, and come with decades of field proven reliability. ## **Typical Applicati** ~~**on**~~ **s** ## **Features** - Mass Spectrometry - Output Voltages from 100V to 6kV - Output Voltage Proportional to Input - Low Turn-on Voltage 0.7VDC - Input to Output Isolation - Electrostatic Chucks - Electrophoresis - Capacitor Charging • Particle C ~~ounte~~ r - Ignition/Spark - Sustaining Ion Pumps - Dual Output Models - No Minimum Load ## **Dimensions** - 3 Year Warranty **1.50 x 1.50 x 0.63" (38.1 x 38.1 x 16.0mm)** ## **Block Diagram** **==> picture [505 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>1<br>(+) Output<br>(+) In<br>+ 5<br>] RECTIFIER & i.<br>OSCILLATOR Center Tap (for Dual Output option)<br>MULTIPLIER<br>2<br>(-) In Transformer 4 (-) Output<br>**----- End of picture text -----**<br> DC-HVDC CONVERTER ## G Series ## **Input** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage|0.7||12|VDC|| |Input Current, No Load|||175|mA|See Models and Ratings Table.| |Input Current, Full Load|||400|mA|See Models and Ratings Table.| ## **Output** **==> picture [540 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|||6000|VDC|See Models & Ratings table| |Output Current|||15|mA|See Models & Ratings table| |Output Voltage Tolerance||±3||%|At Max Vout, Full Load| |Minimum Load|No minimum load required||||| |Regulation|Unregulated, Output is proportional to Input. Unloaded output voltage is typically 10% higher than unloaded.||||| |Ripple and Noise|0.1||2.0|%|See Models & Ratings table| |Response Time||15||msec|0 to Max Vout, Full Load [G01 to G60]| ## **Environmental** **==> picture [539 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Operating Temperature|-10||+60|°C|Case temperature| |Storage Temperature|-25||+90|°C|| |Cooling|Natural convection||||| |Humidity|||95|%RH|Non-condensing| ## **General** |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Isolation: Input to Output|||3500|V|<±3500 Bias| |Switching Frequency|60||190|kHz|Stable frequency over entire output voltage range| |Construction|Case material is Diallyl Phthalate (DAP). UL 94 V-0 rated solid vacuum encapsulation||||| |Mean Time Between Failure|2.29|||Mhrs|Bellcore TR 332| ## Notes: 1. Maximum rated output current is available at maximum rated output voltage and derates linearly as input voltage is decreased. 2. Output voltage is load dependent. Under light or no-load conditions, reduce the input voltage so maximum rated output voltage is not exceeded. 3. Specifications after 30 minute warm-up, full load, at 25°C unless otherwise indicated. 4. Proper thermal management techniques are required to maintain safe case temperature at maximum power output. 5. Ripple specification for center-tapped units applies to the voltage between the positive and negative output terminals. 6. Models G40, G50 & G60 do not have internal bleeder resistors on the output. Provisions must be made externally to discharge the output capacitors. 2 DC-HVDC CONVERTER ## G Series ## **Safety Approvals** |Safety Agency|Standard|Notes & Conditons| |---|---|---| |UL|IEC/UL/CSA/EN 62368|| |CE|Meets all applicable directives|| |RoHS|RoHS 2 and 3 Directive (2011/65/EU)|Where applicable| ## **External EMI/RFI Shield** **==> picture [273 x 218] intentionally omitted <==** **----- Start of picture text -----**<br> 4-40 solderable<br>grounding stud 2.40<br>2 places (61.0) ø 0.140 (3.56) thru<br>2 places<br>0.300<br>(7.62) 0.300<br>(7.62) 1.60<br>(40.6)<br>0.80 0.20<br>(20.3) (5.1)<br>2.000<br>(50.80)<br>1.60<br>(40.6)<br>0.31<br>(7.9)<br>HIGH 0.68<br>VOLTAGE (17.3)<br>0.40<br>(10.2)<br>**----- End of picture text -----**<br> An AB suffix is used to indicate an added external EMI/RFI Shield as shown above. These five-sided aluminum enclosures feature a durable, non-conductive black anodized finish. On models with outputs of 3kV or higher, special care must be taken to ensure adequate spacing and insulation between the metal can and the high voltage output. Single sided layout, encapsulation, or conformal coating may be required. Case grounding studs must be connected to ground. Case ground is not connected to (-) Input. Specifications subject to change without notice. 3 DC-HVDC CONVERTER ## G Series ## **Models & Ratings** **==> picture [540 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> input Current<br>Model Number Output Voltage Output Current [(1)] Ripple<br>No Load Full Load<br>**----- End of picture text -----**<br> |Model Number|Output Voltage|Output Current(1)|input Current<br>No Load<br>Full Load|input Current<br>No Load<br>Full Load|Ripple| |---|---|---|---|---|---| |G01|0 to 100V|15mA|<100mA|<250mA|<1.75%| |G01CT|0 to +/-50V|15mA|<100mA|<250mA|<1.75%| |G02|0 to 200V|7.5mA|<100mA|<250mA|<0.75%| |G02CTAB|0 to +/-100V|7.5mA|<100mA|<250mA|<0.75%| |G03|0 to 300V|5mA|<100mA|<250mA|<0.75%| |G03CTAB|0 to +/-150V|5mA|<100mA|<250mA|<0.75%| |G04|0 to 400V|3.75mA|<100mA|<250mA|<0.75%| |G04CTR|0 to +/-200V|3.75mA|<100mA|<250mA|<0.75%| |G05|0 to 500V|3mA|<100mA|<250mA|<0.1%| |G06|0 to 600V|2.5mA|<100mA|<250mA|<0.1%| |G10|0 to 1000V|1.5mA|<100mA|<250mA|<0.1%| |G12|0 to 1200V|1.25mA|<150mA|<275mA|<0.1%| |G12AB|0 to 1200V|1.25mA|<150mA|<275mA|<0.1%| |G12CTR|0 to +/-600V|1.25mA|<150mA|<275mA|<0.1%| |G15|0 to 1500V|1mA|<125mA|<275mA|<0.5%| |G15AB|0 to 1500V|1mA|<125mA|<275mA|<0.5%| |G20|0 to 2000V|0.75mA|<165mA|<275mA|<0.5%| |G25|0 to 2500V|0.6mA|<125mA|<275mA|<1%| |G25AB|0 to 2500V|0.6mA|<125mA|<275mA|<1%| |G25CT|0 to +/-1250V|0.6mA|<125mA|<275mA|<1%| |G30|0 to 3000V|0.5mA|<125mA|<300mA|<2%| |G30AB|0 to 3000V|0.5mA|<125mA|<300mA|<2%| |G30CT|0 to +/-1500V|0.5mA|<125mA|<300mA|<2%| |G40|0 to 4000V|0.37mA|<125mA|<300mA|<1%| |G40RAB|0 to 4000V|0.37mA|<125mA|<300mA|<1%| |G50|0 to 5000V|0.3mA|<125mA|<300mA|<2%| |G50AB|0 to 5000V|0.3mA|<125mA|<300mA|<2%| |G50CT|0 to +/-2500V|0.3mA|<125mA|<300mA|<2%| |G60|0 to 6000V|0.25mA|<125mA|<300mA|<2%| |G60RAB|0 to 6000V|0.25mA|<125mA|<300mA|<2%| |G60CT|0 to +/-3000V|0.25mA|<125mA|<300mA|<2%| |G60CTAB|0 to +/-3000V|0.25mA|<125mA|<300mA|<2%| |GPMT|0 to 1250V|0.35mA|<35mA|<75mA|<0.05%| Notes: 1. All orderable part numbers are listed above. 2. CT indicates dual output, center tap. Negative side will be ~10% larger than positive side w.r.t. the center tap pin. 3. AB suffix indicates external shield, see Mechanicals. 4. R suffix is used as a RoHS indicator for legacy models. 5. Model GPMT is rated for 0.4375 Watts. 4 DC-HVDC CONVERTER ## G Series ## **Mechanical Details** G01 to G40 G01CT to G12CT **==> picture [34 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Top View<br>**----- End of picture text -----**<br> PCB Layout **==> picture [409 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> * Optional<br>1.50 0.15 1.200 dual output<br>(38.1) (3.8) (30.48) (center tap)<br>4<br>2 1.000<br>1.50 0.800 *5<br>(25.40)<br>(38.1) (20.32) 0.500<br>1<br>3 (12.70)<br>0.63 0.20<br>(16.0) (5.1)<br>0.35<br>0.25<br>(8.9)<br>(6.4)<br>0.031 Ø PC pin Recommended<br>(0.79) *5 places hole & pad O.D. size:<br>Ø0.052 (1.32 ) & Ø0.082 (2.08 )<br>*5 places<br>HIGH<br>VOLTAGE<br>**----- End of picture text -----**<br> G50 to G60 G25CT to G60CT Top View PCB Layout **==> picture [540 x 212] intentionally omitted <==** **----- Start of picture text -----**<br> * Optional<br>1.50 0.15 1.200 dual output<br>(38.1) (3.8) (30.48) (center tap)<br>4<br>2<br>1.50 0.800 *5 1.200<br>(38.1) (20.32) 0.600 (30.48)<br>1<br>3 (15.24)<br>0.63 0.20<br>(16.0) (5.1)<br>0.35 0.15<br>(8.9) (3.8) Pin Function<br>0.031 Ø PC pin 1 (+) Input<br>(0.79) 5 places Recommended 2 (-) Input<br>hole & pad O.D. size:<br>3 (+) Output<br>Ø0.052 (1.32) & Ø0.082 (2.08)<br>*5 places 4 (-) Output<br>5 Dual Output/Center Tap (Optional)<br>HIGH<br>VOLTAGE<br>**----- End of picture text -----**<br> Notes: 1. All dimensions are in inches (mm) 2. Weight 1.5oz (43g) 3. Tolerance: X.XX±0.02 (0.51) 4. Pin Tolerance: ±0.005 (0.127) Specifications subject to change without notice. 5 DC-HVDC CONVERTER ## G Series ## **Application Notes** Positive Output Negative Output **==> picture [177 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> +Vin 1 3 +Vout<br>-Vin 2 4<br>**----- End of picture text -----**<br> **==> picture [202 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> +Vin 1 3<br>-Vin 2 4 -Vout<br>**----- End of picture text -----**<br> Dual Output **==> picture [177 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> +Vin 1 3 +Vout<br>5<br>-Vin 2 4 -Vout<br>**----- End of picture text -----**<br> Typical Output vs. Input Voltage **==> picture [354 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>110<br>100<br>80<br>No Load<br>60<br>Full Load<br>40<br>20<br>0<br>0 10 20 30 40 50 60 70 80 90 100<br>Input Voltage (%)<br>Output Voltage (%)<br>**----- End of picture text -----**<br> 6 24 Jan 2022
Updated at April 22, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →