Image not available
Illustrative purposes only
FX3U-232ADP-MB
MODBUS Communication Adapter, FX3U, 1 Channel, RS-232, 74 mm x 17.6 mm x 90 mm, MELSEC-F Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MITSUBISHI
- Product type: Controller Accessories
- SVHC: No SVHC (15-Jan-2018)
- Product Range: MELSEC FX3U
- Current Rating: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 273.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
## FX3U-232ADP-MB FX3U-485ADP-MB # Explore the Possibilities! rN th ~ Le **FX Modbus** New ## **Modbus Serial Communication Adapter** **==> picture [552 x 323] intentionally omitted <==** **----- Start of picture text -----**<br> Enabling the FX3U PLC to be a Master or N:N Networking Computer Link<br>Station1 Station2<br>Slave on to your Modbus network! RS-485 RS-485 RS-485<br>Also supports all previous serial FX-485PC-IF<br>communication functions including<br>FX3U-485-ADP-MB FX3U-485-ADP-MB<br>N:N Networking, Computer Link, Inverter<br>communication, RS and RS2 instructions, etc. Inverter communication FX3U-485-ADP-MB RS and RS2 instructions<br>Inverter Bar-code reader<br>Inverter<br>*For detailed information on all other supported<br>serial communication functions, refer to the FX Series<br>“gh LU: User’s Manual - Data Communication Edition ge ae oe a Printer FX3U-485-ADP-MB<br>Oe Modbus Specifications - —<br>System Configuration Communication Specifications<br>Item Specifications<br>Communicationadapter Special adapterconnection board Communication Adapter Communication BoardExpansion/ PLC Channels per PLC FX3U-232ADP-MB1 ChannelFX3U-485ADP-MB<br>FX3U-CNV-BD Communication Interface RS-232C RS-485<br>FX3U-485ADP-MB FX3U-485-BD FX3U Transmission Speed 300, 600, 1200, 2400, 4800, 9600, or 19200 bps<br>+ + + FX3U-232-BD V2.40 or Transmission Data Length 7-bit or 8-bit<br>FX3U-232ADP-NB FX3U-422-BD Higher Specifications Stop Bit 1-bit or 2-bit<br>FX3U-USB-BD Transmission Distance Up to 15m (49’2") Up to 500m (1640’5")<br>Communication Protocol RTU or ASCII<br>Number of Slaves 1 Slave 16 Slaves<br>In the case of RS-232C In the case of RS-485 Number of Functions 14 (+14 Diagnostic functions)<br>Jp == 15m (49’ 2") - \- [$l!] 500m (1640 ’ 5 " ) MasterFunction Number of Simultaneously Executable InstructionsMaximum Write Data 123 words or 1968 coils1 Instruction<br>FX PLC FX PLC FX PLC FX PLC FX PLC Maximum Read Data 125 words or 2000 coils<br>Master station Slave station Master station Slave station Slave station<br>No. 1 (01H) No. 1 (01H) No. 16 (10H) Number of Functions 14 (+14 Diagnostic functions)<br>Number of Simultaneous<br>units17 SlaveFunction Acceptable Request 1 Request Message<br>Messages<br>Station Number 1 to 247<br>Special External Dimensions 90 (H) x 17.6 (W) x 74 (D) [mm]<br>[eect a ee | Adapter Weight 80g<br>**----- End of picture text -----**<br> Note: Modbus Slave Nodes do not need to be numbered in any specific order ## _**Modbus Communication Setup**_ Modbus serial communication parameters and communication execution are setup easily within the ladder program using GX Developer. The FX3U Modbus Master uses a new dedicated command, ADPRW, to communicate with Modbus Slaves on the network. **==> picture [314 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> *Master Function requires GX Developer Version 8.45X or Higher<br>Command Slave Command Code<br>input Node Command Parameters<br>(normally ON) Address Code<br>FNC276 S • S1 • S2 • S3 • S4 • / D •<br>ADPRW<br>=<br>Command Parameters<br>depending on the<br>Command Code<br>= = Command Code<br>Slave Node Address<br>00H to 10H (0 to 16)<br>**----- End of picture text -----**<br> **==> picture [191 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Command List<br>Read Coils Return Bus Communication Error Count<br>Read Discrete Inputs Return Bus Exception Error Count<br>Read Holding Registers Return Slave Message Count<br>Read Input Registers Return Slave No Response Count<br>Write Single Coil Return Slave NAK Count<br>Write Single Register Return Slave Busy Count<br>Read Exception Status Return Bus Character Overrun Count<br>Return Query Data Get Comm. Event Counter<br>Restart Communication Option Get Comm. Event Log<br>Return Diagnostic Register Write Multiple Coils<br>Change ASCII Input Delimiter Write Multiple Registers<br>Force Listen Only Mode Report Slave ID<br>Clear Counters and Diagnostic Register Mask Write Register<br>Return Bus Message Count Read/Write Multiple Registers<br>**----- End of picture text -----**<br> ## aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN New publication, effective Aug.2007 Specifications subject to change without notice. HIME-L009A0708 Printed in Japan (MEE)
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →