FX29K0-100A-0050-L
LOAD CELL SENSOR, 50LB, 5.5V
- Manufacturer: TE CONNECTIVITY
- Product type: Force Sensors & Load Cells
- Load Capacity: 50lb
- Product Range: FX29 Series
- Supply Voltage: 5.5V
- Operating Temperature Max: 50°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 32.83 € |
| Current stock | 10+ |
| Lead time | 7 days |
te.com ## FX29 ## Compact Compression Load Cell Versatile Miniature Force Sensor mV, Amplified, and Digital Outputs Low Power Consumption Rugged Microfused Sensing Element Stainless Steel Enclosure Several Load Ranges ## Features - Compact Design - mV or Amplified Analog Outputs - Optional I[2] C Digital Interface - High Over Range Capability ## Applications - Medical Infusion Pumps - Analog & Digital Scales - Fitness & Exercise Equipment TE Connectivity’s (TE) FX29 is a compact compression load cell that offers exceptional price-to-performance in a robust sensor package. Optimized for embedded force sensing applications from disposable medical devices to durable appliances and exercise equipment. The FX29 allows design flexibility with mV, amplified, and digital output options. The FX29 incorporates the high reliability Microfused technology and is offered in ranges from 10lbf to 200lbf (50N to 1000N). Microfused technology provides excellent span and zero stability, outstanding cycle life, superior resolution, high over-range capabilities, and an unamplified span sensitivity of 20mV/V. The FX29 utilizes a two-piece construction of stainless steel materials. The combination of a metal injection molded flexure and micro miniaturized MEMS strain gauges allows flexibility of force range options for a lower cost sensor. These improvements over previous load cell designs give the FX29 more precise dimensional control and better performance. - Payload Weighing - Power Tools - Robotics - Surgical & Dental Tools - Battery Powered Devices - Manufacturing Equipment CLICK HERE[›] **CONNECT WITH A SPECIALIST** TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 1 FX29 Compact Compression Load Cell ## Absolute Maximum Ratings (Analog)[ (1)] |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Supply voltage|Vdd|||6.0|V|Analog mV Output| |||||5.25|V|Analog 0.5-4.5V Output| |Storage temperature|TS|-40||+85|°C|| |Compressive load|Lmax|||2.5X|Rated|| |ESD||-4.0||4.0|kV|Human Body Model| (1) Maximum limits the device will withstand without damage ## **Standard Load Ranges** |**Pounds-Force(lbf)**|**Newtons(N)**| |---|---| |10|50| |25|125| |50|250| |100|500| |200|1000| ## Electrical Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Supply voltage (Vsupply)|Vdd|1.00||6.0|V|mV Output only| |||4.75||5.25|V|0.5-4.5V Output only| |Operating current|Idd|||3|mA|0.5-4.5V Output only| |Input resistance|Rin|2.4|3.0|3.6|kΩ|mV Output only| |Output resistance|Rout|1.76|2.2|2.64|kΩ|mV Output only| |Rise time|Tr|||2.0|ms|10% to 90%| |Maximum output current|Io|2.2|||mA|0.5-4.5V Output only| |Output short circuit duration|Ts|||∞|seconds|0.5-4.5V Output only| |Insulation resistance||50|||MΩ|@250VDC| |Bandwidth||||1.0|kHz|| TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 2 FX29 Compact Compression Load Cell ## Operating Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Zero offset1||-15||15|mV/V|mV Output only| |||300|500|700|mV|0.5-4.5V Output only| |Full scale span1||16|20|24|mV/V|mV Output only| |||3800|4000|4200|mV|0.5-4.5V Output only| |Non-linearity||-1||1|%Span|BFSL| |Hysteresis||-0.8||0.8|%Span|| |Zero repeatability||-0.8||0.8|%Span|| |Span repeatability||-0.8||0.8|%Span|| |Thermal shift for zero||-0.05||0.05|%Span/°C|Reference to 25°C, over<br>compensated temperature| |Thermal shift for span||-0.05||0.05|%Span/°C|| |Cycle life||1E+6||||0 to full scale cycles| |Deflection at rated load||||0.03|mm|| |Weight|||6.0||grams|Without ribbon cable| (1) Span and zero offset are ratiometric to power supply voltage ## Environmental Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Compensated temperature<br>range|To|0||50|°C|0.5-4.5V Output only| |Storage temperature|Ts|-40||85|°C|| |Ambient humidity||0||85|%RH|Non-condensing| |EMI/RFI/ESD protection||IEC61000-4-2 (8kVair/4kVcontact)<br>IEC61000-4-3 (3V/m)<br>EN55032 Class A||||mV Output only| |Ingress protection|IP|43||||| |Media compatibility||External exposed surfaces: 17-4 and 304<br>stainless steel||||Excluding cable &<br>connector| TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 3 FX29 Compact Compression Load Cell ## Schematic Diagram – mV output (Analog) Block Diagram – 0.5 to 4.5V output (Analog) **==> picture [87 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> Vdd<br>Vsuprcy<br>ANALOG<br>OUTPUT OWNIZACHire™<br>**----- End of picture text -----**<br> TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 4 FX29 Compact Compression Load Cell ## Absolute Maximum Ratings (Digital)[ (1)] |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Supply voltage||||5.50|V|| |Storage temperature|TS|-40||+85|°C|| |Compressive load|Lmax|||2.5X|Rated|| |ESD||-4.0||4.0|kV|Human Body Model| (1) Maximum limits the device will withstand without damage ## Standard Load Ranges |**Pounds-Force(lbf)**|**Newtons(N)**| |---|---| |10|50| |25|125| |50|250| |100|500| |200|1000| ## Electrical Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Supply voltage (Vsupply)|Vdd|2.7||5.5|V|| |Operating current|Idd|||3|mA|| |Sleep mode current|Islp||0.5|5|µA|| |Insulation resistance||50|||MΩ|@250VDC| TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 5 FX29 Compact Compression Load Cell ## Force Operating Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Zero offset||300|1000|1700|Counts|Base10| |Full scale span||14300|15000|15700|Counts|Base10| |Non-linearity||-1||1|%Span|BFSL| |Hysteresis||-0.8||0.8|%Span|| |Zero repeatability||-0.8||0.8|%Span|| |Span repeatability||-0.8||0.8|%Span|| |Thermal shift for zero||-0.05||0.05|%Span/°C|Reference to 25°C, over<br>compensated temperature| |Thermal shift for span||-0.05||0.05|%Span/°C|| |Cycle life||1E+6||||0 to full scale cycles| |A/D resolution|||14||Bits|| |Response time||||3|mS|4MHz, non-sleep mode| |||||8.4|mS|4MHz, sleep mode| |Deflection at rated load||||0.03|mm|| |Weight|||6.0||grams|Without ribbon cable| ## Environmental Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) |**Parameter**|**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Compensated temperature<br>range|To|0||50|°C|| |Storage temperature|Ts|-40||85|°C|| |Ambient humidity||0||85|%RH|Non-condensing| |Ingress protection|IP|43||||| |Media compatibility||External exposed surfaces: 17-4 and 304<br>stainless steel||||Excluding cable &<br>connector| TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 6 FX29 Compact Compression Load Cell Block Diagram – I[2] C Digital Output (Digital) **==> picture [20 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> SDA<br>SCL<br>**----- End of picture text -----**<br> TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 7 FX29 Compact Compression Load Cell ~~a~~ ## Force Output Graph (Digital) |**%Output**|**Counts(decimal)**|**Counts(hex)**| |---|---|---| |0%|1000|0x3E8| |5%|1700|0x6A4| |10%|2400|0x960| |50%|8000|0x1F40| |90%|13600|0x3520| |95%|14300|0x37DC| |100%|15000|0x3A98| ## I[2] C Typical Circuit Note: only one pair of pull up resistors are needed for multiple sensing devices. TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 8 FX29 Compact Compression Load Cell ## I[2] C Interface |I[2]C Interface|I[2]C Interface|||||| |---|---|---|---|---|---|---| |**Parameter**<br>**Symbol**||**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |SCLK clock frequency|FSCL|100||400|kHz|| |Start condition hold time relative to<br>SCL edge|tHOSTA<br>~~|~~<br>~~ee~~|0.1<br>|<br>~~ee~~||<br>~~ee~~|~~ff~~<br>~~ee~~|µS<br>~~ff~~<br>~~ee~~|| |Minimum SCL clock low width1|tLOW<br>~~ee~~|0.6<br>~~ee~~|~~ee~~|~~ee~~|µS<br>~~ee~~|| |Minimum SCL clock high width1|tHIGH<br>~~ee ~~|0.6<br> ~~ee~~|~~ee ~~|~~ee~~|µS<br>~~ee~~|| |Start condition startup time relative to<br>SCL edge|tSUSTA<br>~~|~~|0.1<br>||||~~ff~~|µS<br>~~ff~~|| |Data hold time on SDA relative to SCL<br>edge|tHDDAT|0|||µS|| |Data setup time on SDA relative to<br>SCL edge|tSUDAT|0.1|||µS|| |Stop condition setup time on SCL|tSUSTO|0.1|||µS|| |Bus free time between stop and start<br>condition|tBUS<br>~~|~~|2<br>||||~~|~~|µS<br>~~|~~|| ## I[2] C Interface Timing Diagram ## Digital Input and Output Parameters (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) |**Parameter**<br>**Symbol**|**Parameter**<br>**Symbol**|**Min**|**Typ**|**Max**|**Units**|**Notes/Conditions**| |---|---|---|---|---|---|---| |Input high voltage|VIH|0.8||1.0|x Vdd|| |Input low voltage|VIL|0.0V||0.2|x Vdd|| |Output low level|||||x Vdd|| |Load capacitance @ SDA||||200|pF|@400 kHz| |Input capacitance (each pin)||||10|pF|| TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 9 FX29 Compact Compression Load Cell ## I[2] C Measurement Packet Read Sequence TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 10 FX29 Compact Compression Load Cell ## General Working Mode TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 11 FX29 Compact Compression Load Cell ## ~~Te~~ ## Outline Drawing and Connections TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 12 FX29 Compact Compression Load Cell ~~a~~ ## Mounting Recommendation The sensor can be put into a simple slot fixture for load testing. The load should be applied to the spherical face of center boss. Recommended to stick the sensor with double face 3M adhesive or glue. Some feature to clamp the sensor from top to down can be optional. See below for reference: NOTE: Clamping force may shift the zero reading slightly. Re-zero if needed. Below table shown the Zero change difference when loaded 5 Lbf from the top. (For reference only) |**Load Range **|10L|25L|50L|100L| |---|---|---|---|---| |**Changing for reference**|±0.5%FS|±0.4%FS|±0.35%FS|±0.25%FS| Dimension for reference: TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 13 **==> picture [519 x 431] intentionally omitted <==** **----- Start of picture text -----**<br> FX29<br>Compact Compression Load Cell<br>Ordering Information<br>– – –<br>FX29 X X XXX X XXXX X<br>Output Signal Measurement Units<br>Code Output Output Type L Pounds-force (lbf)*<br>2 20 mV/V* mV N Newtons<br>3 0.5 – 4.5V* Amplified<br>J I [2] C Digital<br>Load Range<br>(None Sleep)<br>LBF Newtons<br>K I [2] C (Sleep)* Digital<br>0010* 0050<br>— I [2] C Address | = 0025* 0125<br>Code Device Address (hex) 0050* 0250<br>X Analog Output* 0100* 0500<br>0 0x28* 0200 * 1000<br>1 0x36 (MACHINING)<br>2 0x46<br>3 0x48<br>4 0x51<br>Cable & Connector<br>Code Cable and Connector<br>Cable Length A 4-wire ribbon cable without connector<br>Code Length B 4-wire ribbon cable with connector*<br>040 40 mm* Note: For digital output, ensure custom cable<br>100 100 mm* length does not exceed 1 meter.<br>= XXX Custom Length<br>*Sensor features shown in bold are typically stocked by our distribution partners, or available with short lead times from the<br>factory depending on availability. Contact customer service for details.<br>**----- End of picture text -----**<br> ## **Caution:** For the digital sensor. User can change the address along with the guide as below link. **Please notice, any data changed by users means users give up the quality assurance terms. TE will not guarantee the sensor performance any more.** https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7FDIGITAL_MODEL S_CHANGING_I2C_SLAVE_ADDRES%7FA1%7Fpdf%7FEnglish%7FENG_SS_DIGITAL_MODELS_CHANGING_I2C_SLAVE_ADDRES_A1 .pdf%7FCAT-PTT0015 TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 14 FX29 Compact Compression Load Cell ## REVISION HISTORY |REVISION HISTORY|||| |---|---|---|---| |**Revision Number**|**Change Description**|**Date**|**Approval**| |A3|Minor corrections ;|06/24/2019|MH| |A4|Correct pin numerical to be same as connector|07/29/2020|MH| |A5|Mounting Recommendation and Caution added;|10/27/2020|MH| ## CLICK HERE[›] ## **CONNECT WITH A SPECIALIST** **NORTH AMERICA EUROPE ASIA** Tel +1 800 522 6752 Tel +31 73 624 6999 Tel +86 0400 820 6015 ## **te.com/sensors** Microfused, Measurement Specialties (MEAS), TE Connectivity, TE, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2020 TE Connectivity Corporation. All Rights Reserved. TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 15
Updated at February 9, 2023
TE Connectivity is a globally recognized engineering and manufacturing leader, specializing in highly reliable connectivity and sensing solutions. Renowned for innovation and durability, their components are engineered to perform in the most demanding environments, supporting critical advancements in industrial equipment, data communications, and automotive systems. Our extensive selection of TE Connectivity products is anchored by their industry-leading connector portfolio. We carry a comprehensive array of terminal blocks and accessories, including wire-to-board, pluggable, standard, and barrier configurations, alongside robust backplane connectors designed to ensure secure and efficient power and data transmission in complex circuit designs. Beyond physical connections, TE Connectivity is a premier manufacturer of precision sensors, antennas, and electromechanical switching components. Our inventory features a wide variety of RF antennas and highly accurate pressure, temperature, and force transducers. Additionally, we provide an expansive range of TE's dependable relays, encompassing automotive, power, and signal variants, alongside essential passive components like shielding gaskets and RF inductors to fully support your engineering requirements.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →