FMA-500-T1-40W-GV
Air Flow Sensor, FMA Series, Filtration Air Restriction, Analog, 1/8-27 NPT, 40in H2O, Vacuum Gage
- Manufacturer: AMPHENOL ADVANCED SENSORS
- Product type: Pressure Switches
- Flow Rate:-; Flow Rate Max:-; Pressure Max:10000Pa; Supply Voltage DC Min:4.75V; Supply Voltage DC Max:5.25V; Accuracy %:2.5%; Port Size:-; Product Range:FMA Series; SVHC:No SVHC (15-J
- SVHC: No SVHC (07-Jul-2017)
- Accuracy %: 2.5%
- Deadband Max: -
- Deadband Min: -
- Pressure Type: Vacuum Gauge
- Product Range: NovaSensor FMA Series
- Pressure Port Size: 1/8"-27
- Pressure Port Type: NPT Female
- Supply Voltage Max: 5.25V
- Supply Voltage Min: 4.75V
- Contact Configuration: -
- Supply Voltage DC Max: 5.25V
- Supply Voltage DC Min: 4.75V
- Switching Current Max: -
- Switching Voltage Max: -
- Operating Pressure Max: 40Inch-H2O
- Operating Pressure Min: -
- Operating Temperature Max: 125°C
- Operating Temperature Min: -40°C
- Transducer Connection / Termination: Connector
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 79.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Filtration Air FMA Series Restriction Sensor For improved air filtration system performance, the NovaSensor FMA Series of Filtration Air Restriction (FAR) Sensors accurately measures pressure loss across a variety of air filtration devices utilizing high accuracy NPA piezoresistive technology in a low-profile form factor that is easy to install and maintenance-free. With configurable thresholds, the FMA Series can be easily installed for use in a variety of applications, including commercial and automotive HVAC and industrial air filters, engine air filtration systems and rooftop units exposed to pressure or vacuum environments. With hydrophobic reference port and sealed connection system, it can also be used in a variety of harsh environmental conditions. The FMA Series is available in multiple positive or vacuum pressure ranges, mating with an integrated AMPSEAL 16 (3-way) electrical connector (Drawing No. C-776402-1-GEN) and a 1/8-27 NPT female pressure connection port. ## Applications ## Features - Engine Air Filter Restriction - Cabin Pressure - HVAC Pressure - Exhaust Pressure - Industrial Filters - Supply Voltage: 5VDC - Linear Output: 0.5V to 4.5V (Ratiometric) - Diagnostic Features (Bridge Connection Checks, Bridge Short Detection, Power Loss Detection) - Temperature-Compensated - Sealed AMP Electrical Connector - Multiple Pressure Ranges Available (Vacuum and Pressure) - Fast Response Time - REACH & RoHS Compliant **Amphenol Advanced Sensors** ## Technical Specifications ## **Electrical** |Supply Voltage (VDD)(1)|5 VDC +/-5%| |---|---| |Supply Current|5 mA Max| |Output Voltage (VO)<br>(Ratiometric)|0.5 to 4.5 V (10% to 90% VDD)| |Output Impedance|250 Ohms Max| |Over Voltage|28 V Momentary Contact| |Reverse Voltage|28 V Momentary Contact| |ESD Rating|Contact: 8 kV; Air: 15 kV| |EMC Compliance|RE (150 kHz - 3.2 GHz)<br>CI (30 Hz - 50 kHz)<br>BCI (10 kHz - 400 MHz)<br>RI (100 kHz - 3.2 GHz)| |Accuracy|+/- 2.5% FSO| |---|---| |Resolution|0.12% FSO| |Compensated Temp Range|0°C to 80°C<br>0°C to 60°C for 5”H2O| |Proof Pressure|2X Full Pressure| |Burst Pressure|3X Full Pressure| |Vibration|20-2000Hz AT 11.5 Grms| |OperatingTempRange|-40°C to 125°C| |Storage TempRange|-55°C to 150°C| |Start-UpTime|10 ms| |Response Time|< 2 ms| |Intended Media|Clean DryAir| |ClampLimits Upper/Lower|92.5% to 7.5% VDD| |Diagnostic Limits Upper/Lower|97.5% to 2.5% VDD| |Pressure Ranges Available|5” H2O<br>10” H2O(2)<br>40” H2O<br>1 PSI(2)<br>5 PSI| [1] Use 5 VDC +/- 2.5% for 5” H2O [2] Contact factory for additional custom pressure ranges. ## Connector Pin Out and Port Thread **2** ## Transfer Function **==> picture [333 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> (90% VDD) 4.5 ppannannnnnnnnnnnn nanan nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nn nnn nnn ===<br>FSO<br>VDD: Power Supply Voltage<br>4<br>Vo: Sensor Output Voltage<br>Zero: Sensor Output Voltage at Zero-scale Pressure<br>z 3.5<br>FSO: Sensor Output Voltage at Full-scale Pressure<br>ay<br>°<br>><br>e€<br>8 2.5<br>eZ<br>2<br>815<br>1<br>Zero<br>(10% VDD) 0.5 +------<% Lower clipping limit<br>**----- End of picture text -----**<br> ## Transfer Function Parameters |**Parameter**|**Unit**|**Typical**|**Output**| |---|---|---|---| |**Upper Clipping Limit**<br>**Lower Clipping Limit**<br>**Upper Diagnostic Level**|VDD<br>VDD<br>VDD|92.5%<br>7.5%<br>97.5%|4.625 V<br>0.375 V<br>4.875 V| |**Lower Diagnostic Level**|VDD|2.5%|0.125 V| **3** ## Ordering Information **FMA Code Description** 500 Analog Amplified Output, 5.0 VDC Excitation, Calibrated **Code Description** T1 Pressure Port, 1/8-27 NPT Female **Code Description** 05W 5 in H2O (1.25 kPa) 10W 10 in H2O (2.5 kPa)* 40W 40 in H2O (10 kPa) 001 1 PSI (7 kPa)* 005 5 PSI (35 kPa) **Code Description** GV Vacuum Gage GP Positive Gage FMA _____ _____ _____ _____ - Typical Order Number *Contact factory for additional custom pressure ranges. ## **Amphenol Advanced Sensors** www.amphenol-sensors.com © 2019 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. **AAS-920-707E - 05/2019**
Updated at June 9, 2026
Amphenol Advanced Sensors is a leading innovator in sensor technologies and measurement solutions, serving the highly regulated and demanding needs of the transportation, medical, and industrial markets. Through its renowned legacy brands—including Thermometrics for temperature sensing, NovaSensor for pressure, and Telaire for air quality—the company delivers a diverse portfolio of critical components designed to provide accurate environmental data for real-time decision-making. The core of this manufacturer's offering focuses heavily on highly reliable circuit protection and transducer components. Engineers will find an extensive selection of temperature sensing and compensation NTC thermistors, alongside a comprehensive range of high-performance pressure sensors and transducers. These precision-engineered devices are essential for ensuring thermal stability, accurate fluid measurement, and reliable operational feedback in complex commercial and industrial applications. Beyond these primary lines, the selection includes vital power management devices such as inrush current limiting (ICL) NTC thermistors and PTC thermistors engineered to safeguard sensitive electronics. The portfolio is further complemented by specialized temperature sensors, light sensors, and dataloggers, providing a robust, integrated suite of measurement and protection solutions for modern hardware design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →