Image not available
Illustrative purposes only
FLS400-1348-TF
AC/DC Enclosed Power Supply (PSU), Top Fan, ITE, 1 Outputs, 400 W, 48 VDC, 8.3 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EOS POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: FLS400 Series
- No. of Outputs: 1Outputs
- Output Power Max: 400W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8.3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 109.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
**ITE Grade FLS400 Watt AC-DC Power Supplies** ee EO: ## **400 Watt** - l 400 Watts Forced Cooled - l Efficiency up to 90% - l -40 to 70 degree operating temperature - l High power density : 23.70W/inch[3] - l Thermal Shut-Down feature / Dual fusing - l 2.56m Hours, Telcordia -SR332-issue 3 MTBF The New FLS400 Series is designed to work with Forced air cooling. This is a highly efcient power supply that can deliver up to 400 W with air. This new series comes with two options. ie. Casing with Side Fan and Top Fan. ## ~~**400 Watts**~~ |**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**1| |---|---|---|---|---| |||||| |FLS400-1312<br>FLS400-1315|with JST Connector<br>with JST Connector<br>12V<br>15V|25A<br>20A|0.0A<br>0.0A|5%<br>5%| |FLS400-1324|with JST Connector<br>24V|16.70A|0.0A|2%| |FLS400-1330|with JST Connector<br>30V|13.30A|0.0A|2%| |FLS400-1348<br>FLS400-1358|with JST Connector<br>with JST Connector<br>48V<br>58V|8.30A<br>6.90A|0.0A<br>0.0A|2%<br>2%| For Top FAN vesrion add “TF” Ex. FLS400-1324-TF For Side FAN version add “SF” Ex. FLS400-1324-SF ## ~~**Pin Connection**~~ |~~**Pin Connection**~~||| |---|---|---| |J1 (Input)|PIN 1|AC LINE| ||PIN 2|NOT FITTED| ||PIN 3|AC NEUTRAL| |J2 (Output)|PIN 1,2,3|V1 +VE| ||~~PIN 4,5,6~~|~~V1 -VE~~| |Self clinching nut||Earth| |(J9)|PIN 1|+VS (Remote Sense)| |Signal Connector|PIN 2|-VS (Remote Sense)| ~~**www.eospower.com**~~ ~~4EM-21-295 1 39-DE60-49855-002 / A~~ **ITE Grade AC-DC Power Supplies** **FLS400 Watt** ## Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 2. Specifications are for nominal input voltage, 25°C unless otherwise stated. 3. 400W with Forced cooling at 115 VAC to 264VAC. 4. Combine Output Power of Main Output, Fan supply should not exceed 400 W. 5. Output ripple can be more than 2 % of the output voltage. ## **Input** |**Input**|**Input**|**Input**|**Input**|**Input**|**Input**|**Input**|**Input**| |---|---|---|---|---|---|---|---| ||**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|| ||Input Voltage|85||264|VAC|De-rate linearly from 100% at 115VAC to 70% at 85VAC|| ||Input Frequency|47||63|Hz||| ||Input Current|||6.3|A||| ||Inrush Current|||75|A||| |Power Factor||exceeds 0.95 at Full Load|||||| ## ~~**Output**~~ ~~**Characteristic Minimum Typical Maximum Units Notes & Conditions**~~ Output Power 400 ~~W es ssQQ Oe GG~~ Hold-up Time 8mS ~~At 230 VAC GO~~ Line Regulation +/-0.5% Load Regulation +/-0.5% e ~~sGG~~ a Output Voltage Adjustability ~~GG~~ +/-3% Rise Time 55 ~~ms esGG~~ Set Point Tolerance +/-1% ~~ee Ge ee~~ Over Current Protection ~~GG~~ > 105% ~~ee~~ Over Voltage Protection 110 to 140% ~~Cs~~ Transient Response ~~Qe~~ 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms ## ~~**General**~~ |~~**General**~~|~~**General**~~| |---|---| |**Characteristic Minimum Typical Maximum Units Notes & Conditions**|| |Efficiency<br>90%|At 230 VAC| |Mean Time BetweenFailure<br>2.56m Hours|Telcordia -SR332-issue 3| |<br>Isolation: Input to Output<br>Input to Ground<br>4000<br>2500|~~ITAV~~<br>~~VDC~~| |Leakage Current<br>300 uA Typical|| ~~**www.eospower.com**~~ ~~4EM-21-295 2 39-DE60-49855-002 / A~~ ## **FLS400 Watt** ## **ITE Grade AC-DC Power Supplies** ## **Efficiency Vs Load** ## **Environmental** ||**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**| |---|---|---|---|---|---|---|---| ||**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|| ||Operating Temperature|-40||70|°C|-40 to 0 startup is guaranteed with spec deviation.<br>70°C (Derated)|| ||Storage Temperature|-40||85|°C||| ||Relative Humidity|5||95|%|RH, non-condensing|| ||Operating Altitude|||16,000|ft||| ||Short Circuit Protection||Hiccup mode||||| ||<br>Switching Frequency||PFC – 70 to 130 KHz ,PWM – 50-80 KHz||||| ||Cooling|||||Inbuilt Fans for cooling|| ||||||||| **www.eospower.com** ~~4EM-21-295 3 39-DE60-49855-002 / A~~ **ITE Grade FLS400 Watt AC-DC Power Supplies** i. ## **Mechanical Specifications** AC Input Connector (J1) TE Connectivity: 647676-3 Mating: 1-1123722-3 ; Crimp: 1123721-2 DC Output Connector (J2) TE Connectivity: 647676-6 Mating: 1-1123722-6 ; Crimp: 1123721-2 Earth Ø4.25 Self clinching nut, (PEM S-M3-0-ZI) or Equivalent Dimensions CK with Top Fan 123.7 x 77.2 x 82.3 approx mm CK with Side Fan 135 x 109 x 50 mm Weight 700 gm approx ## **EMC: Emissions** **==> picture [496 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Phenomenon|Standard Test Level Notes & Conditions| |Conducted|EN 55032|Level B|CISPR22-B, FCC PART15-B| |Radiated|EN 55032|Level A|Level B with external core| |(King core K5B RC 25x12x15-M or Equivalent| |in input cable)| **----- End of picture text -----**<br> ## ~~**EMC: Immunity**~~ **==> picture [438 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Phenomenon Standard Test Level Criteria Notes & Conditions| |Input CurrMedical D|e|nt Harmonicsvice EMC|EN 61000-3-2|Class A| |VL|o|w Voltage PSU EMCltage Fluctuaton and Flicker|EN 61000-3-3|compliance| |ESD ImmunityESD Immunity|EN 61000-4-2|Level 3|A| |Radiated Field ImmunityRadiated Immunity|EN 61000-4-3|Level 3|A| |Electrical Fast Transient ImEFT/Burst|munity|EN61000-4-4|Level 3|A| |Surge ImmunitySurge|EN 61000-4-5|Level 3|A| |Conducted ImmunityConducted Immunity|EN61000-4-6|Level 3|A| |Magnetc Field Immunity|EN61000-4-8|Level 3|A| |Voltage dips, interruptons|EN61000-4-11|A & B| **----- End of picture text -----**<br> ## ~~**Safety Approvals**~~ **==> picture [434 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Safety Agency|[Safety Standard]|Notes & Conditions| |CB|IEC 62368-1:2018| |Nemko|EN 62368-1:2020;A11| |ITAV| |UL|UL62368-1 ED 3.0| |CSA|CAN/CSA C22.2 No. 62368-1:19| |CE Mark|Complies with LVD Directve| **----- End of picture text -----**<br> ~~4EM-21-295 4 39-DE60-49855-002 / A~~ ~~**www.eospower.com**~~ ## **ITE Grade FLS400 Watt AC-DC Power Supplies** ee EO: ## **Derating Curve** De-rate linearly from 100% at 115VAC to 70% at 85VAC ## **Derating Curve** Forced air cooled load: 400W up to 40 °C. De-rate by 1.66% / °C above 40°C till 70°C 4EM-21-295 5 39-DE60-49855-002 / A **www.eospower.com** **ITE Grade FLS400 Watt AC-DC Power Supplies** ee EO: ## **Derating Curve** Forced air cooled load: 300W up to 40 °C. De-rate by 1.66% / °C above 40°C 4EM-21-295 6 39-DE60-49855-002 / A **www.eospower.com** ## **ITE Grade FLS400 Watt AC-DC Power Supplies** ee EO: ## **Mechanical Drawing** **==> picture [170 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Cover kit with Top FAN<br>**----- End of picture text -----**<br> 4EM-21-295 7 39-DE60-49855-002 / A **www.eospower.com** **ITE Grade FLS400 Watt AC-DC Power Supplies** ee EO: ## **Mechanical Drawing** ## **Cover kit with Side FAN** **www.eospower.com** 4EM-21-295 8 39-DE60-49855-002 / A
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →