FLN-EMSS0000105
Flexi Loop, Node, EMSS, 5 Pin M12 Female Connector, FLN Series
- Manufacturer: SICK
- Product type: Industrial Switch Accessories
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 65.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
FLN-EMSS0000105 Flexi Loop **SAFE SERIES CONNECTION / SAFETY CONTROLLERS** **FLN-EMSS0000105 | Flexi Loop** SAFE SERIES CONNECTION / SAFETY CONTROLLERS **==> picture [423 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Ordering information| |Type|Part no.| |FLN-EMSS0000105|1061711| |Other models and accessories|www.sick.com/Flexi_Loop| |irs|lili...| **----- End of picture text -----**<br> ## CE Ws ## Detailed technical data ## Safety-related parameters **==> picture [484 x 376] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Safety integrity level|SIL 3 (IEC 61508)| |Category|Category 4 (EN ISO 13849)| |Performance level|PL e (EN ISO 13849)| |PFHD (mean probability of a dangerous fail-|0.76 x 10|[-9]|(EN ISO 13849)| |ure per hour)| |TM (mission time)|20 years (EN ISO 13849)| |Functions| |Diagnostic and monitoring functions| |Cross-circuit|Monitoring via Flexi Loop node| |Short-circuit|Monitoring via Flexi Loop node| |Discrepancy errors|Monitoring via Flexi Loop node| |Sequence errors|Monitoring via Flexi Loop node| |Interfaces| |Connection usage| |Safety device connection|For dual-channel equivalent electro-mechanical safety switch (EMSS)| |Flexi Loop input|To connect to a Flexi Loop predecessor node or to connect the Flexi Loop line to the Flexi Soft| |safety controller.| |Flexi Loop output|To connect to a Flexi Loop successor node or to terminate the Flexi Loop line with the Flexi| |Loop terminator.| |Connection type| |Safety device connection|Female connector M12, 5-pin| |Flexi Loop input|Male connector M12, 5-pin| |Flexi Loop output|Female connector M12, 5-pin| |Number of non-safe inputs|0| |Number of non-safe outputs|0| **----- End of picture text -----**<br> ## Functions ## Interfaces ## Electrical data ## Operating data **==> picture [277 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Protection class|III (EN 61140)| |Type of supply voltage|PELV or SELV| |Supply voltage Vs|24 V DC (16.8 V DC ... 30 V DC)| **----- End of picture text -----**<br> **Product data sheet | 2024-03-01 04:19:48 Subject to change without notice** **2 SAFE SERIES CONNECTION | SICK** **FLN-EMSS0000105 | Flexi Loop** SAFE SERIES CONNECTION / SAFETY CONTROLLERS |**Power consumption**|55 mA| |---|---| |EMSS interface|| |**Test pulse interval**|40 ms| |**Test pulse width**|12 ms| |**Test pulse current via the switch contacts**|3 mA ... 6.2 mA| |Mechanical data|| |**Dimensions (W x H x D)**|68.15 mm x 48 mm x 18 mm| |**Weight**|28 g (± 5 %)| |Ambient data|| |**Enclosure rating**|IP65 (EN 60529)<br>IP67 (EN 60529)| |**Ambient operating temperature**|–25 °C ... +55 °C| |**Storage temperature**|–25 °C ... +70 °C| |Classifications|| |**eCl@ss 5.0**|27371990| |**eCl@ss 5.1.4**|27371990| |**eCl@ss 6.0**|27371819| |**eCl@ss 6.2**|27371819| |**eCl@ss 7.0**|27371819| |**eCl@ss 8.0**|27371819| |**eCl@ss 8.1**|27371819| |**eCl@ss 9.0**|27371819| |**eCl@ss 10.0**|27371819| |**eCl@ss 11.0**|27371819| |**eCl@ss 12.0**|27371819| |**ETIM 5.0**|EC001449| |**ETIM 6.0**|EC001449| |**ETIM 7.0**|EC001449| |**ETIM 8.0**|EC001449| |**UNSPSC 16.0901**|41113704| **2024-03-01 04:19:48 | Product data sheet Subject to change without notice** **SAFE SERIES CONNECTION | SICK** **3** **FLN-EMSS0000105 | Flexi Loop** SAFE SERIES CONNECTION / SAFETY CONTROLLERS ## Dimensional drawing (Dimensions in mm (inch)) OSSD, EMSS **==> picture [195 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> ~<br>en<br>LIE<br>dt<br>10.75 45 12.4<br>(0.42) (1.77) (0.49)<br>15.2 (0.6) M12x 1 Ø 18<br>(Ø 0.71)<br>48<br>(1.89)<br>36.5 (1.44)<br>11.5 (0.45) 11.5 (0.45)<br>**----- End of picture text -----**<br> PIN assignment |||||||||||||||||||||||||||||||||||||||1|1|2|| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||||||||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||||||||4||3|EMSS| |||||||||||||||||||||||||||||||||||||||||5|| |3<br>5<br>4<br>2<br>1<br>4<br>5<br>3<br>1<br>2<br>FL_OUT<br>FL_IN<br>The FL_IN pin assignment is only relevant for the first loop node in a safe series connection when connected to Flexi Soft. Addition-<br>col~~Oto! ~~ae)|||||||||||||||||||||||||||||||||||||||||| |al Flexi Loop nodes are connected to FL_OUT using standardized cables with M12 plug connectors.||||||||||||||||||||||||||al Flexi Loop nodes are connected to FL_OUT using standardized cables with M12 plug connectors.|||||||||||||||| |**Con-**||**Pin**||**Sig-**|||||||||||**Description**|||||||||||||||||||||||||**Col-**|| |**nec-**||||**nal**||||||||||||||||||||||||||||||||||||**or-cod-**|| |**tion**||||||||||||||||||||||||||||||||||||||||**ed**|| |||||||||||||||||||||||||||||||||||||||||**con-**|| |||||||||||||||||||||||||||||||||||||||||**nect-**|| |||||||||||||||||||||||||||||||||||||||||**ing**|| |||||||||||||||||||||||||||||||||||||||||**cable**|| |FL_IN||1||VDC|||||||||24 V supply voltage||||||||||||||24 V supply voltage|||||||||||||Brown|| |||2||DA-||||Output to Flexi Soft input In +1||||||||||||||||||||Output to Flexi Soft input In +1|||||||||Output to Flexi Soft input In +1|||White|| |||||TA_OUT|||||||||||||||||||||||||||||||||||||| |||3||GND|||||||||GND supply voltage||||||||||||||GND supply voltage|||||||||||||Blue|| |||4|SAFE_OUT|||||||||Safe cut-off signal, out-|||||||||||||||||||||Safe cut-off signal, out-|||||||Black|| |||||||||||||put to Flexi Soft input In||||||||||||put to Flexi Soft input In||||put to Flexi Soft input In|||||||||||||| |||5||DA-||||Input from Flexi Soft output Xn|||||||||||||||||||||Input from Flexi Soft output Xn||||||||Input from Flexi Soft output Xn|||Gray|| |||||TA_IN|||||||||||||||||||||||||||||||||||||| |EMSS||1|EMSS1_A|||||||||||Switching contact||||||||||||Switching contact||||||||||||||Brown|| |||||||||||||||1, connection A|||||||||||||||||1, connection A||||||||||| |||2|EMSS1_B|||||||||||Switching contact||||||||||||Switching contact||||||||||||||White|| |||||||||||||||1, connection B|||||||||||||||||1, connection B||||||||||| |||3|EMSS2_A|||||||||||Switching contact||||||||||||Switching contact||||||||||||||Blue|| |||||||||||||||2, connection A|||||||||||||||||2, connection A||||||||||| |||4|EMSS2_B|||||||||||Switching contact||||||||||||Switching contact||||||||||||||Black|| |||||||||||||||2, connection B|||||||||||||||||2, connection B||||||||||| **4 SAFE SERIES CONNECTION | SICK** **Product data sheet | 2024-03-01 04:19:48 Subject to change without notice** **FLN-EMSS0000105 | Flexi Loop** SAFE SERIES CONNECTION / SAFETY CONTROLLERS |**Con-**|**Pin**|**Pin**||**Sig-**||**Description**|**Col-**| |---|---|---|---|---|---|---|---| |**nec-**||||**nal**|||**or-cod-**| |**tion**|||||||**ed**| ||||||||**con-**| ||||||||**nect-**| ||||||||**ing**| ||||||||**cable**| ||5|EMSS2_A||||Switching contact|Gray| |||||||2, connection A|| |EMSS pin 3 and EMSS pin 5 can be used as alternatives.||||EMSS pin 3 and EMSS pin 5 can be used as alternatives.|||| |||The colors listed apply when using pre-|||||| |||||assembled cables (no guarantee).|||| ## Recommended accessories Other models and accessories www.sick.com/Flexi_Loop **Brief description Type Part no.** ~~ee~~ Mounting brackets and plates 1 piece, Flexi Loop fixing clip C-Fix bracket 2068830 3 ~~|~~ **2024-03-01 04:19:48 | Product data sheet Subject to change without notice** **SAFE SERIES CONNECTION | SICK** **5** ## SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” ## WOrldWIde preSenCe: Contacts and other locations www.sick.com SICK AG | Waldkirch | Germany | www.sick.com
Updated at June 9, 2026
SICK is a globally recognized leader in factory and logistics automation technology, renowned for engineering advanced sensors and developing innovative digital services. Driven by a commitment to high precision, reliability, and versatility, the company provides the foundational components required to transform traditional manufacturing processes into intelligent, self-optimizing systems that adapt autonomously using real-time data. Our comprehensive selection of SICK products is heavily focused on their industry-leading sensing technologies. We offer a robust portfolio of light sensors designed to deliver exceptional accuracy and performance in demanding industrial environments. Furthermore, our extensive range features high-quality proximity sensors and switches, providing the dependable object detection essential for automated production, packaging, and material handling applications. To ensure seamless integration of these advanced sensor networks, our offering is complemented by specialized connectivity solutions such as SICK fiber optic lead assemblies. From consumer goods and electronics to logistics and automotive manufacturing, SICK delivers the cutting-edge automation technology necessary to maximize operational efficiency and maintain continuous, reliable performance across diverse industrial sectors.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →