Image not available
Illustrative purposes only
FE514.650AB3C
COUNTER, PRESET, 24VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: IVO
- Product type:
- No. of Digits / Alpha:6; Digit Height:4.5mm; Supply Voltage Min:21.6VDC; Supply Voltage Max:26.4VDC; Panel Cutout Height:51mm; Panel Cutout Width:51mm; Operating Temperature Min:0°C; Operating Tem
- Digit Height: 4.5mm
- Product Range: -
- Panel Cutout Width: 51mm
- Supply Voltage Max: 26.4VDC
- Supply Voltage Min: 21.6VDC
- Panel Cutout Height: 51mm
- No. of Digits / Alpha: 6
- Operating Temperature Max: 60°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 89.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button** ## **FE504, FE514, FE524** ## **Features** - **Preset counter with one preset** - - - - **Adding** - **Display 6-digits** - **With reset button** FE504 - Socket box ## **Technical data - electrical ratings** FE514 - Front panel with screw mount **==> picture [131 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> =<br>**----- End of picture text -----**<br> |Voltage supply|24/110 VAC ±10 % (50/60 Hz)| |---|---| ||230 VAC +6/-10 % (50/60 Hz)| ||24 VDC ±10 %| |Ripple residue|<48 %| |Nominal frequency|50 / 60 Hz| |Pulse ratio|1:1| |Service life|VDC - 100 million impulses| ||VAC - 50 million impulses| |Preset|1preset| |Output contact|Change-over contact by micro-| ||switch, one-pole| |Switchingcapacity|100 VA / 30 W| |Limit switch service life|1 million switchingcycles| |Spark extinguisher|Recommended for inductive| ||load| |Standard|Protection class II| |DIN EN 61010-1|Overvoltage category II| ||Pollution degree 2| |Emitted interference|DIN EN 61000-6-4| |Interference immunity|DIN EN 61000-6-2| www.baumer.com/motion 1 # **Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button** ## **FE504, FE514, FE524** ## **Technical data - mechanical design** |Display|White numbers on black| |---|---| |Number of digits|6-digits| |Digit height|4.5 mm| |Count mode|1 impulse = 1 count| |Step-by-stepswitching|Addingin 2 half steps| |Measuringrange|999 999| |Reset|Manual byreset button| |Operatingtemperature|0...+60 °C| |Storingtemperature|-20...+70 °C| |Relative humidity|80 % non-condensing| |Protection DIN EN 60529|IP 41| |Connection|Soldering pins(fat)| |Weight approx.|160g| |Material|Housing: Noryl PPO, black| |**FE504**|| |Housingtype|Socket box| |Mounting|Socket box| |Dimensions W x H x L|50 x 50 x 88.1 mm| |Cutout dimensions|50 x 50 mm| |Installation depth|88.3 mm| |**FE514**|| |Housingtype|Built-in housing| |Mounting|Frontpanel with 2 screws| |Dimensions W x H x L|60 x 75 x 61.3 mm| |Cutout dimensions|51 x 51 mm| |Installation depth|79.7 mm| |**FE524**|| |Housingtype|Built-in housing| |Mounting|Frontpanel with springclips| |Dimensions W x H x L|53.2 x 53.2 x 61 mm| |Cutout dimensions|51 x 51 mm| |Installation depth|79.7 mm| ## **Connection diagram** ||||||||||| |---|---|---|---|---|---|---|---|---|---| ||||||||||| ||||||||||| |3<br>4||21||20|||22||| ||||||||||| ||||||||||| ||||||||||| |+<br>(-)|-<br>(+)||||||||| |Voltage|||End||contact||||| |**Trigger level**|||||||||| |**Max. counting speed**||||||**10pulses/s**|||| |Voltage|||||||24/110 VAC ±10 %||| ||||||||230 VAC +6/-10 %||| |Power|||||||3 VA||| |Min.pulse duration|||||||50 ms||| |Min.pulse interval|||||||50 ms||| |Switch on|time(at 25||||°C)||100 %||| |**Max. counting speed**||||||**20**|**pulses/s**||| |Voltage|||||||24 VDC ±10 %||| |Power|||||||2 W||| |Min.pulse duration|||||||25 ms||| |Min.pulse interval|||||||25 ms||| |Switch on|time(at 25||||°C)||100 %||| ## **Accessories** **Front panels for FE504** Z 100.02A Front panel with transparent protective cover, for socket box 50 x 50 mm |**Accessories**<br>**Frontpanels**<br>Z 100.02A|**for FE504**<br>Front panel with transparent protective cover,<br>for socket box 50 x 50 mm| |---|---| |**Front frames**|**for FE504**| |Z 102.01A|Front frame with knob lock provided on| ||transparent cover| |Z 102.02A|Front frame with cylinder lock provided on| ||transparent cover| |Z 107.02A|Front frame, insertion cutout 50 x 50 mm| www.baumer.com/motion 2 **Preset counters electromechanic 1 preset, adding** ## **Display 6-digits, manual reset button** ## **FE504, FE514, FE524** **Part number Socket box FE504. 650B C** Display C 6-digits 999 999 Voltage B3 24 VDC B5 24 VAC B8 110 VAC B9 230 VAC Reset 650B With reset button **Front panel with screw mount FE514. 650A C** Display C 6-digits 999 999 Voltage B3 24 VDC B5 24 VAC B8 110 VAC B9 230 VAC Reset 650A With reset button **Front panel with spring clips mount** **FE524. 650B C** Display C 6-digits 999 999 Voltage B3 24 VDC B5 24 VAC B8 110 VAC B9 230 VAC Reset 650B With reset button www.baumer.com/motion 3 # **Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button** ## **FE504, FE514, FE524** ## **Dimensions** ## **FE504 socket box** **==> picture [242 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> 49.6 6.5<br>20.7 67.4<br>49.6<br>**----- End of picture text -----**<br> ## **FE514 front panel with 2 screws** **==> picture [242 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 30 6.5<br>4.85 50.3 61.3 2.7<br>60<br>12.35 6<br>75 50.3 63<br>**----- End of picture text -----**<br> ## **FE524 front panel with spring clip** **==> picture [242 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> 53.2 6.5<br>1.45 50.3 6<br>18.4 61.3 2.7<br>1.45<br>53.2 50.3<br>**----- End of picture text -----**<br> www.baumer.com/motion 4
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →