- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: FDLC-80
- Output Current: 2.1A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 80W
- Input Voltage Max: 295V
- Input Voltage Min: 180V
- Output Voltage Max: 54VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 18.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**FDLC - 80 series** 80W Constant Power Mode LED Driver ## ■ ## **IP67** ■ ## ■ ~ ℃ ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:FDLC-80-SPEC 2019-01-22_ **FDLC - 80 series** ## 80W Constant Power Mode LED Driver ## **SPECIFICATION** ## **MODEL** |**MODEL**<br>**OUTPUT CURRENT**<br>**CONSTANT POWER**<br>**OUTPUT**<br>**SET UP TIME**<br>**Note.3**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms/230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>**REGION**<br>**OUTPUT VOLTAGE**<br>**Note.2**<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>COLD START 50A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>260<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>10 units (circuit breaker of type B) / 17 units (circuit breaker of type C) at 230VAC<br>℃<br>℃<br>℃<br>180 ~ 295VAC 254 ~ 417VDC<br><0.5W<br>30 ~ 54V<br>**FDLC-80**<br>1000~ 2100mA<br>80W<br>60V<br>90%<br>0.5A / 230VAC 0.4A/277VAC<br>**WORKING TEMP.**<br>Compliance to EN55015, EN61000-3-2 Class C (load<br>60%) ; EN61000-3-3,GB17743,GB17625.1<br>≧<br>,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-30 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±0.03%/<br>(0 ~ 50<br>)<br>℃<br>℃<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>498.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>151*53*31.5mm (L*W*H)<br>0.454Kg; 24pcs / 11.9Kg / 0.73CUFT<br>Shut down output voltage, recovers automatically after fault condition is removed<br>THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-30 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>PF<br>0.95/230VAC, PF<br>0.90/277VAC@full load<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>EN61347-1,EN61347-2-13 Independent, EN62384,GB19510.1,GB19510.14,EAC TP TC 004,IP67 approved<br>i<br>ee<br>~~se~~<br>ee<br>~~Ge~~<br>~~ee~~<br>re<br>~~se~~<br>ee~~SS~~<br>~~eG~~<br>ee<br>ee<br>Re<br>ee<br>re<br>~~eG~~<br>aee<br>a<br>a<br>ee<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 _ of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|**MODEL**<br>**OUTPUT CURRENT**<br>**CONSTANT POWER**<br>**OUTPUT**<br>**SET UP TIME**<br>**Note.3**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms/230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>**REGION**<br>**OUTPUT VOLTAGE**<br>**Note.2**<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>COLD START 50A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>260<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>10 units (circuit breaker of type B) / 17 units (circuit breaker of type C) at 230VAC<br>℃<br>℃<br>℃<br>180 ~ 295VAC 254 ~ 417VDC<br><0.5W<br>30 ~ 54V<br>**FDLC-80**<br>1000~ 2100mA<br>80W<br>60V<br>90%<br>0.5A / 230VAC 0.4A/277VAC<br>**WORKING TEMP.**<br>Compliance to EN55015, EN61000-3-2 Class C (load<br>60%) ; EN61000-3-3,GB17743,GB17625.1<br>≧<br>,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-30 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±0.03%/<br>(0 ~ 50<br>)<br>℃<br>℃<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>498.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>151*53*31.5mm (L*W*H)<br>0.454Kg; 24pcs / 11.9Kg / 0.73CUFT<br>Shut down output voltage, recovers automatically after fault condition is removed<br>THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-30 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>PF<br>0.95/230VAC, PF<br>0.90/277VAC@full load<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>EN61347-1,EN61347-2-13 Independent, EN62384,GB19510.1,GB19510.14,EAC TP TC 004,IP67 approved<br>i<br>ee<br>~~se~~<br>ee<br>~~Ge~~<br>~~ee~~<br>re<br>~~se~~<br>ee~~SS~~<br>~~eG~~<br>ee<br>ee<br>Re<br>ee<br>re<br>~~eG~~<br>aee<br>a<br>a<br>ee<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 _ of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|**FDLC-80**| |---|---|---| ||**OUTPUT CURRENT**<br>i<br>ee|1000~ 2100mA| ||**CONSTANT POWER**<br>i<br>ee|80W| ||**REGION**<br>**OUTPUT VOLTAGE**<br>**Note.2**<br>ee<br>~~se~~<br>ee|30 ~ 54V<br>~~se~~| ||**OPEN CIRCUIT VOLTAGE(max.)**<br>~~se~~<br>ee<br>~~Ge~~|60V<br>~~se~~<br>~~Ge~~| ||**CURRENT TOLERANCE**<br>ee<br>~~Ge~~|±5.0%<br>~~Ge~~| ||**SET UP TIME**<br>**Note.3**<br>~~ee~~|500ms/230VAC<br>~~ee~~| ||**VOLTAGE RANGE**<br>~~ee~~<br>re<br>~~SS~~|(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC 254 ~ 417VDC<br>~~ee~~<br>~~SS~~| ||**FREQUENCY RANGE**<br>re<br>~~SS~~|47 ~ 63Hz<br>~~SS~~| ||**POWER FACTOR (Typ.)**<br>re<br>~~SS~~|PF<br>0.95/230VAC, PF<br>0.90/277VAC@full load<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>~~SS~~| ||**TOTAL HARMONIC DISTORTION**<br>~~SS~~|THD< 20%(@load 60%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>~~SS~~| ||**EFFICIENCY (Typ.)**<br>~~se~~<br>ee~~SS~~|90%<br>~~se~~<br>~~SS~~| ||**AC CURRENT (Typ.)**<br>~~se~~<br>ee~~SS~~|0.5A / 230VAC 0.4A/277VAC<br>~~se~~<br>~~SS~~| ||**INRUSH CURRENT(Typ.)**<br>ee~~SS~~|COLD START 50A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>260<br>Per NEMA 410<br>μ<br>;<br>~~SS~~| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>~~SS~~|10 units (circuit breaker of type B) / 17 units (circuit breaker of type C) at 230VAC<br>~~SS~~| ||**LEAKAGE CURRENT**<br>~~SS~~|<0.75mA / 277VAC<br>~~SS~~| ||~~SS~~|<0.5W<br>~~SS~~| ||**SHORT CIRCUIT**<br>~~SS~~<br>~~eG~~<br>ee|Hiccup mode, recovers automatically after fault condition is removed<br>~~SS~~<br>~~eG~~| ||**OVER TEMPERATURE**<br>~~eG~~<br>ee|Shut down output voltage, recovers automatically after fault condition is removed<br>~~eG~~| ||**WORKING TEMP.**<br>ee<br>ee|Tcase=-30 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃| ||**MAX. CASE TEMP.**<br>ee<br>Re|Tcase=+90℃| ||**WORKING HUMIDITY**<br>ee<br>Re<br>ee|20 ~ 95% RH non-condensing| ||**STORAGE TEMP., HUMIDITY**<br>Re<br>ee<br>re|-30 ~ +80<br>, 10 ~ 95% RH<br>℃| ||**TEMP. COEFFICIENT**<br>ee<br>re|±0.03%/<br>(0 ~ 50<br>)<br>℃<br>℃| ||**VIBRATION**<br>re|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes| ||**SAFETY STANDARDS**|EN61347-1,EN61347-2-13 Independent, EN62384,GB19510.1,GB19510.14,EAC TP TC 004,IP67 approved| ||**WITHSTAND VOLTAGE**<br>~~eG~~<br>a|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>~~eG~~| ||**ISOLATION RESISTANCE**<br>~~eG~~<br>aee|I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~eG~~| ||**EMC EMISSION**<br>aee|Compliance to EN55015, EN61000-3-2 Class C (load<br>60%) ; EN61000-3-3,GB17743,GB17625.1<br>≧<br>,EAC TP TC 020| ||**EMC IMMUNITY**<br>ee|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV),EAC TP TC 020| ||**MTBF**<br>a|498.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃| ||**DIMENSION**<br>a<br>a<br>ee|151*53*31.5mm (L*W*H)| ||**PACKING**<br>℃<br>℃<br>℃<br>0.454Kg; 24pcs / 11.9Kg / 0.73CUFT<br>ee<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 _ of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>6. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|| _File Name:FDLC-80-SPEC 2019-01-22_ **FDLC - 80 series** ## 80W Constant Power Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [461 x 598] intentionally omitted <==** **----- Start of picture text -----**<br> PWM fosc : 45~130KHz<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & SWITCHING & -V<br>RECTIFIERS FILTER<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>FG<br>DEFAULT OUTPUT CURRENT<br>※ I-V Operation Area<br>FDLC-80<br>1000mA,54V 1480mA,54V<br>54V<br>52V<br>50V<br>1000mA,48V<br>48V<br>46V<br>44V<br>42V<br>40V<br>2100mA,38V<br>38V FDLC-80<br>36V<br>34V<br>32V<br>30V<br>1000mA,30V 1600mA,30V 2100mA,30V<br>28V<br>26V<br>24V<br>22V<br>20V<br>800mA 1000mA 1200mA 1400mA 1600mA 1800mA 2000mA 2200mA<br>Current<br>High Performance Region Operational Region<br>Voltage<br>**----- End of picture text -----**<br> ## **DEFAULT OUTPUT CURRENT** _File Name:FDLC-80-SPEC 2019-01-22_ **FDLC - 80 series** 80W Constant Power Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [506 x 374] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>-30 -20 -10 0 15 30 50 60 70 (HORIZONTAL) -30 -20 0 20 45 55 65 75 90 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ 54V 1480mA, Tcase at 80℃<br>100<br>1.00<br>90<br>0.95<br>80<br>70 0.90 277<br>230<br>60 0.85<br>50 0.80<br>40<br>0.75<br>60% 70% 80% 90% 100%<br>180 190 200 210 220 230 240 250 260 270 280 295<br>INPUT VOLTAGE (V) 60Hz LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** FDLC-80 series possess superior working efficiency that up to 90% can be reached in field applications. **==> picture [240 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 54V 1480mA, Tcase at 80℃<br>19.00%<br>17.00%<br>15.00%<br>277<br>13.00%<br>230<br>11.00%<br>9.00%<br>7.00%<br>5.00%<br>60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> **==> picture [99 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 54V 1480mA, Tcase at 80℃<br>**----- End of picture text -----**<br> **==> picture [249 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> 91%<br>90%<br>89%<br>277<br>88% 230<br>87%<br>86%<br>85%<br>60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:FDLC-80-SPEC 2019-01-22_ **FDLC - 80 series** 80W Constant Power Mode LED Driver ## **AC input voltage drop vs. output current characteristics** **==> picture [267 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> AC input drop 10% 8% 5% 3%<br>Io drop <13% <11% <6% <3%<br>NOTE: Output current will return to the rated value within 50ms<br>**----- End of picture text -----**<br> ## **MECHANICAL SPECIFICATION** **==> picture [468 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> CASE NO.:246A Unit:mm<br>151<br>142<br>140<br>300±20 127 300±20<br>tc<br>37<br>AC/N(Blue)<br>AC/L(Brown) +V(Red)<br>-V(Black)<br>PE (Green-Yellow) H05RN 1.0mm²*3C 4xψ4.5 H05RN 1.0mm²*2C<br>4xψ7.5<br>� tc : Max. Case Temperature<br>34.29<br>◎ Note: Please connect the case to FG for the complete EMC deliverance.<br>INSTALLATION MANUAL<br>Please refer to : http://www.meanwell.com/manual.html<br>7<br>24.5 43 53<br>31.5<br>12.63<br>**----- End of picture text -----**<br> _File Name:FDLC-80-SPEC 2019-01-22_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →