FCB100US36
AC/DC Open Frame Power Supply (PSU), ITE, Household & Medical, 1 Output, 100W @ 10CFM, 80 W
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: FCB100 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.6A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Household & Medical
- Power Rating (Forced Cooling): 100W @ 10CFM
- Power Rating (Convection Cooling): 80W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 27.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## FCB100 Series
## 80W **CONVECTIONCOOLED** 100W **FANCOOLED**
## AC-DC POWER SUPPLIES
The FCB100 is a series of open frame AC-DC power supplies designed for medical devices (including BF), industrial electronics, ITE & household applications. The FCB100 is compliant with class B conducted & radiated emissions, can be used in both class I & class II installations and the wide 80VAC to 264VAC operating input range makes it ideal for both home healthcare applications and in hospital use.
With both convection and fan cooled ratings, extremely low emissions and safety & EMC certification for global use, the FCB100 benefits system designers with easy integration into a wide range of applications across multiple end markets
## **Applications**
## **Features**
- 80W convection cooled
- 100W fan cooled
**==> picture [135 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical Household Industrial<br>Appliances Electronics<br>**----- End of picture text -----**<br>
- 4” x 2” footprint, low 1.25” profile
- Class I & Class II applications
- Medical (BF), ITE & household approvals
- Class B conducted & radiated emissions
- Input Range 80 to 264VAC
## ~~**Dim**~~ **ensions**
- <0.3W no load input power
- Regulated single outputs from 12 to 48VDC
4.00” x 2.00” x 1.25” (101.6 x 50.8 x 31.8mm)
- Short circuit, overvoltage & overload protection
- -25°C to +70°C operating temperature
## **Models & Ratings**
|Model Number<br>FCB100US12|Output Power<br>100W|Output Voltage<br>12.0VDC|Convection cooled (40°C)<br>7.5A|Convection cooled (50°C)<br>6.7A|
|---|---|---|---|---|
|FCB100US15||15.0VDC|6.0A|5.3A|
|FCB100US19||19.0VDC|4.7A|4.2A|
|FCB100US24||24.0VDC|4.0A|3.5A|
|FCB100US36||36.0VDC|2.6A|2.4A|
|FCB100US48||48.0VDC|2.0A|1.8A|
AC-DC POWER SUPPLIES
## FCB100 Series
## **Input**
**==> picture [540 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br>
|Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons|
|---|---|---|---|---|---|
|Input Voltage|80||264|VAC|Derate from 100% at 90VAC to 90% at 85VAC and 80% at 80VAC|
|Input Frequency|47||63|Hz||
|Input Current - Full Load||1.8/1.1||A rms|115/230VAC full load|
|No Load Input Power|||0.3|W||
|Inrush Current|||60|A|At 264VAC, cold start 25°C|
|Earth Leakage Current|||270|μA||
|Input Protection|Internal T3.15A/300VAC fuse ftted in line and neutral|||||
## **Output**
**==> picture [540 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br>
|Characteristc<br>|Minimum<br>|Typical|Maximum<br>|Units<br>|Notes & Conditons|
|---|---|---|---|---|---|
|Output Voltage|12||48|VDC||
|Initial Set Accuracy|||1.5|%|At 50% load|
|Minimum Load|No minimum load required|||||
|Line Regulation|||±0.5|%|90-264VAC|
|Load Regulation|||±1|%||
|Start Up Delay|||2|s||
|Start Up Rise Time|||50/150|ms|≥0°C/<-10°C|
|Overshoot|||5|%||
|Hold Up Time|8|14||ms|At full load and 115/230VAC|
|Transient Response|||4|%|Deviation, recovery within 1% in less than 500μs for a 25%<br>load change|
|Ripple & Noise|||1|%|0°C to 70°C|
|Overvoltage Protection|110||150|%Vnom|Recycle input to reset|
|Overload Protection|110||175|%||
|Short Circuit Protection|Trip and restart (hiccup mode)|||||
|Patient Leakage Current|||95|μA||
|Overtemperature Protection|Measured internally, recycle input to reset|||||
|Temperature Coeffcient|||0.02|%/°C||
## **General**
|Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons|
|---|---|---|---|---|---|
|Effciency||87||%|Model dependant|
|Isolation: Input to Output<br>Input to Ground<br>Output to Ground|4000|||VAC|2 x MOPP|
||1500||||1 x MOPP|
||1500||||1 x MOPP|
|Switching Frequency|22||70|kHz||
|Power Density|||10|W/in3||
|Mean Time Between Failure||390||khrs|MIL-HDBK-217F, 25°C GB.|
|Weight||0.35 (160)||lb (g)||
2
AC-DC POWER SUPPLIES
## FCB100 Series
## **EMC: Emissions**
**==> picture [539 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br>
|Phenomenon|Standard|Test Level|Criteria|Notes & Conditons|
|---|---|---|---|---|
|Conducted|EN55032, EN55011|Class B|||
|Radiated|EN55032, EN55011|Class B|||
|Harmonic Current|EN61000-3-2|Class A|||
|Voltage Flicker|EN61000-3-3||||
## **EMC: Immunity**
**==> picture [536 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Phenomenon Standard Test Level Criteria Notes & Conditions<br>EN55024<br>**----- End of picture text -----**<br>
|Phenomenon|Standard<br>EN55024|Test Level|Criteria|Notes & Conditons|
|---|---|---|---|---|
|ITE|EN55035<br>EN55014-2|As below|As below||
|ESD Immunity|EN61000-4-2|4|A|±8kV contact / ±15kV air discharge|
|Radiated Immunity|EN61000-4-3|3|A||
|EFT|EN61000-4-4|3|A||
|Surge|EN61000-4-5|Installation class 3|A||
|Conducted|EN61000-4-6|3|A||
|Magnetic Fields|EN61000-4-8|4|A||
|Dips and Interruptions|EN61000-4-11<br>(100VAC/60Hz)|100% (0VAC) for 8.4ms|A|Pout = 85W|
|||100% (0VAC) for 16.7ms|B||
|||60% (40VAC) for 200ms|B||
|||30% (70VAC) for 500ms|A|Pout = 60W|
|||20% (80VAC) for 5000ms|A||
|||100% (0VAC) for 5000ms|B||
||EN61000-4-11<br>(115VAC/60Hz)|100% (0VAC) for 8.4ms|A||
|||100% (0VAC) for 16.7ms|B||
|||60% (40VAC) for 200ms|B||
|||30% (70VAC) for 500ms|A|Pout = 60W|
|||20% (80VAC) for 5000ms|A||
|||100% (0VAC) for 5000ms|B||
||EN61000-4-11<br>(240VAC/50Hz)|100% (0VAC) for 10ms|A||
|||100% (0VAC) for 20ms|A||
|||60% (96VAC) for 200ms|A||
|||30% (168VAC) for 500ms|A||
|||20% (192VAC) for 5000ms|A||
|||100% (0VAC) for 5000ms|B||
||EN60601-1-2<br>(100VAC/50Hz)|100% (0VAC) for 10ms|A|Pout = 65W|
|||100% (0VAC) for 20ms|A|Pout = 40W|
|||60% (96VAC) for 100ms|A|Pout = 20W|
|||30% (168VAC) for 500ms|A|Pout = 60W|
|||100% (0VAC) for 5000ms|B||
||EN60601-1-2<br>(240VAC/50Hz)|100% (0VAC) for 10ms|A||
|||100% (0VAC) for 20ms|A||
|||60% (96VAC) for 100ms|A||
|||30% (168VAC) for 500ms|A||
|||100% (0VAC) for 5000ms|B||
3
AC-DC POWER SUPPLIES
## FCB100 Series
## **Environmental**
**==> picture [539 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br>
|Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons|
|---|---|---|---|---|---|
|Operating Temperature|-25||+70|°C|Derate linearly from 80W at +50°C to 40W at<br>+70°C (12, 15, 19V models), Convection cooled<br>Derate linearly from 85W at +50°C to 45W at<br>+70°C (24, 36, 48V models), Convection cooled<br>Derate linearly from 100W at +50°C to 50W at<br>+70°C, Fan cooled|
|Storage Temperature|-40||+85|°C||
|Cooling|Convection/Fan cooled (see models and ratings)|||||
|Humidity|||95|%RH|Non-condensing|
|OperatingAltitude|||4000/5000|m|Medical/ITE and Household|
|Shock|IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes|||||
|Vibration|IEC68-2-6, 2g, 10Hz to 500kHz, 10 mins/cycle, 60 mins each cycle|||||
## **Safety Approvals**
|Certfcaton|Standard|Notes & Conditons|
|---|---|---|
||||
|CB Report|IEC60950-1, IEC62368-1, IEC60335|Audio/Video, Information and Communication<br>Technology Equipment, Household and Similar<br>Appliances (report only)|
||IEC60601-1|Medical|
|UL|UL62368-1|Audio/Video, Information and Communication<br>Technology Equipment|
||ANSI/AAMI ES60601-1|Medical|
|EN|EN62368-1|Audio/Video, Information and Communication<br>Technology Equipment - Pending|
||EN60601-1|Medical|
|CE|Meets all applicable directives||
|UKCA|Meets all applicable legislation||
||||
|Isolaton|Standard|Notes & Conditons|
|Primary to Secondary|2 x MOPP (Means of Patient Protection)|IEC60601-1 Ed.3|
|Primary to Earth|1 x MOPP (Means of Patient Protection)||
|Secondary to Earth|1 x MOPP (Means of Patient Protection)||
||||
4
AC-DC POWER SUPPLIES
## FCB100 Series
## **Mechanical Details**
**==> picture [469 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.0 (101.6)<br>0.13 (3.2) - 2x 3.75 (95.3) - 2x<br>1.25 (31.8)<br>0.22 (5.7)<br>1.75<br>(44.5) - 2x<br>2.0 J1 Pin 1<br>(50.8)<br>Pin 1 S| | J2 {_<br>0.97 0.98<br>(24.5) (25.0)<br>0.13 (3.2) - 2x J3 6.35 (0.25) jk 0.22 0.12 (3.0) |<br>faston ground tab<br>(5.6) SMD component height<br>0.33 (8.5)<br>4 x 20.156 (3.96) mounting holes<br>0.2 (5.0) 20.312 (7.92) clearance top and bottom<br>**----- End of picture text -----**<br>
**==> picture [398 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
ee Input Connector J1 ee Output Connector J2 =e J3 Connector<br>Pin Function Pin Function Pin Function<br>1 N 1 Return 6.35 faston E<br>2 No connection 2 Return<br>3 +Vout<br>3 L<br>4 +Vout<br>Mates with MOLEX housing 09-65-3031, Mates with MOLEX housing 09-65-2048,<br>MOLEX series 5194 crimp terminals. MOLEX series 5194 crimp terminals.<br>**----- End of picture text -----**<br>
**Notes:**
1. Dimensions in inches (mm).
3. Tolerances x.xx = ±0.02, .xxx = ±0.010.
2. Weight: 0.35lbs (160g)
27 July 2021
5
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →