Image not available
Illustrative purposes only
FAZ-D5/1-SP
CIRCUIT BREAKER, THERMAL MAGNETIC, 1P, 5A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 1 Pole
- Product Range: FAZ Series
- Current Rating: 5A
- Voltage Rating VAC: 277VAC
- Voltage Rating VDC: 48VDC
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 34.63 € |
| Current stock | 10+ |
| Lead time | 7 days |
## **Overcurrentswitch,5A,1p,typeDcharacteristic** **Partno. FAZ-D5/1 Articleno. 278577 CatalogNo. FAZ-D5/1** ## Similar to illustration ## **Delivery program** |**Deliveryyprogramrogramgramram**|||| |---|---|---|---| |Basic function|||Miniature circuit-breakers| |Number of poles|||1 pole| |Tripping characteristic|||D| |Application|||Switchgear for industrial and advanced commercial applications| |Rated current|In|A|5| |Rated switching capacity acc. to IEC/EN 60947-2||kA|15| |Product range|||FAZ| ## **Technicaldata** |**Technicaldata**|**Technicaldata**|||| |---|---|---|---|---| |**Electrical**||||| ||Standards|||IEC/EN 60947‐2| |||||IEC/EN 60898| ||Rated operational voltage|Ue|V|| |||Ue|V AC|240/415| ||Rated switching capacity acc. to IEC/EN 60947-2||kA|15| ## **DesignverificationasperIEC/EN61439** |**DesignverificationasperIEC/EN61439gnverificationasperIEC/EN61439nverificationasperIEC/EN61439perIEC/EN61439erIEC/EN61439**|||| |---|---|---|---| |Technical data for design verification|||| |Rated operational current for specified heat dissipation|In|A|5| |Heat dissipation per pole, current-dependent|Pvid|W|0| |Equipment heat dissipation, current-dependent|Pvid|W|1.7| |Static heat dissipation, non-current-dependent|Pvs|W|0| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-40| |Operating ambient temperature max.||°C|75| ||||linear, per +1 °C, results in a 0.5% reduction of current carrying capacity| |IEC/EN 61439 design verification|||| |10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verification of thermal stability of enclosures|||Meets the product standard's requirements.| |10.2.3.2 Verification of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |10.2.3.3 Verification of resistance of insulating materials to abnormal heat<br>and fire due to internal electric effects|||Meets the product standard's requirements.| |10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| 04/12/2017 278577 - HPL-ED2017 V31.0 EN 1 / 2 |10.9 Insulation properties|||| |---|---|---|---| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifications for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifications for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leaflet (IL) is observed.| ## **TechnicaldataETIM6.0** Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01 [AAB905011]) |**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**| |---|---|---|---| |Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)|||| |Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01<br>[AAB905011])|||| |Release characteristic|||D| |Number of poles (total)|||1| |Number of protected poles|||1| |Nominal rated current||A|5| |Nominal rated voltage||V|230| |Rated short-circuit breaking capacity Icn EN 60898 at 230 V||kA|10| |Rated short-circuit breaking capacity Icn EN 60898 at 400 V||kA|10| |Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V||kA|15| |Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V||kA|15| |Voltage type|||AC| |Current limiting class|||3| |Frequency||Hz|50 - 60| |Concurrently switching N-neutral|||No| |Suitable for flush-mounted installation|||No| |Over voltage category|||3| |Pollution degree|||2| |Width in number of modular spacings|||1| |Built-in depth||mm|70.5| |Additional equipment possible|||Yes| |Degree of protection (IP)|||IP20| ## **Approvals** |**Approvals**|||| |---|---|---|---| |Product Standards|||IEC/EN 60947-2; IEC/EN 60898; UL 1077; CSA-C22.2 No. 235; CE marking| |UL File No.|||E177451| |UL Category Control No.|||QVNU2, QVNU8| |CSA File No.|||204453| |CSA Class No.|||3215-30| |North America Certification|||UL recognized, CSA certified| |Conditions of Acceptability|||Supplementary Protector only| |Suitable for|||Branch Circuits; not as BCPD| |Current Limiting Circuit-Breaker|||No| |Max. Voltage Rating|||277 VAC; 48 VDC| |Degree of Protection|||IEC: IP20; UL/CSA Type: -| Eaton Industries GmbH http://www.eaton.eu © 04/2017 by Eaton Industries GmbH 278577 - HPL-ED2017 V31.0 EN 04/12/2017 2 / 2
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →