Image not available
Illustrative purposes only
FAZ-D30/3-NA
CIRCUIT BREAKER, THERMAL MAGNETIC, 3P, 30A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Thermal Magnetic Circuit Breakers
- Product Range:FAZ Series; Current Rating:30A; No. of Poles:3 Pole; Voltage Rating VDC:-; Voltage Rating VAC:480V; Circuit Breaker Mounting:DIN Rail 52M9070
- Voltage Rating VAC: 480V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 217.76 € |
| Current stock | 50+ |
| Lead time | 30 days |
## Miniature Circuit Breakers and Supplementary Protectors
## **Miniature Circuit Breakers and Supplementary Protectors**
|**1.1**|**Industrial Circuit Breakers**<br>QUICKLAG®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|**1**|
|---|---|---|---|
||QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW. . . . . . . . . . .|**V4-T1-5**|**1**|
||QUICKLAG Plug-On Ground Fault and Equipment Protectors,<br>Types QPHGFT, QPHGFT, QPGFEP, QPHGFEP. . . . . . . . . . . . . . . . .|**V4-T1-8**|**1**|
||Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . .|**V4-T1-11**<br>**V4-T1-14**|**1**|
||Bolt-On Ground Fault and Equipment Protectors,<br>Types QBGFT, QBHGFT, QBGFEP, QBHGFEP. . . . . . . . . . . . . . . . . .|**V4-T1-17**|**1**|
||Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . .|**V4-T1-20**|**1**|
||Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,|||
||QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|**1**|
||Cable-In/Cable-Out Ground Fault and Equipment Protectors,|||
||Types QCGFT, QCHGFT, QCGFEP, QCHGFEP. . . . . . . . . . . . . . . . . .|**V4-T1-28**|**1**|
||Solenoid-Operated, Remote-Controlled Latching|||
||Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . . . . . . . . . . . . .|**V4-T1-31**|**1**|
||Solenoid Operator—Remote-Controlled Latching for|||
||Type GHBS, GBHS and GHQRSP Breakers . . . . . . . . . . . . . . . . . . .|**V4-T1-34**|**1**|
||International Rated Types HQP, BA, QC, GFMB, GFXBC. . . . . . . . . . .|**V4-T1-37**||
||Special Application Breakers, Types HQP, BA, QC . . . . . . . . . . . . . . .|**V4-T1-40**|**1**|
|**1.2**|**UL 489 DIN Rail Miniature Circuit Breakers**||**1**|
||FAZ-NA Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-49**||
||||**1**|
|**1.3**|**UL 1077 DIN Rail Supplementary Protectors**|||
||FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-67**|**1**|
|**1.4**|**UL 1053 DIN Rail RCCB**||**1**|
||UL 1053 DIN Rail RCCB 480/277 Vac . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-87**||
||UL 1053 DIN Rail RCCB 208Y/120 Vac . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-93**|**1**|
Learn Online
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-1**
## Revision notes
Volume 4—Circuit Protectors, CA08100005E
Tab 1—Miniature Circuit Breakers and Supplementary Protectors
|**Revision date**||**Section**|**Change page(s)**|**Description**|
|---|---|---|---|---|
|11/30/2016||1.3|V4-T1-70|Content edit|
**==> picture [140 x 45] intentionally omitted <==**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Miniature Circuit Breakers and Supplementary Protectors**
## **Contents**
## _**Description**_
Quick Reference
## **QUICKLAG**
## **Quick Reference**
**Eaton’s QUICKLAG Industrial Circuit Breakers**[1] **Plug-In, Bolt-On, Cable-In/Cable-Out**
|**Eaton’s QUICKLAG Industrial Circuit Breakers**|**Eaton’s QUICKLAG Industrial Circuit Breakers**|**Eaton’s QUICKLAG Industrial Circuit Breakers**|**Eaton’s QUICKLAG Industrial Circuit Breakers**|**Eaton’s QUICKLAG Industrial Circuit Breakers**[1] **Plug-In, Bolt-On, Cable-In/Cable-Out**|**Plug-In, Bolt-On, Cable-In/Cable-Out**|**Plug-In, Bolt-On, Cable-In/Cable-Out**|**Plug-In, Bolt-On, Cable-In/Cable-Out**|**Plug-In, Bolt-On, Cable-In/Cable-Out**||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Continuous**|||||**Interrupting Ratings rms Symmetrical Amperes**||**Interrupting Ratings rms Symmetrical Amperes**|||||
|**Circuit**<br>**Breaker**|**Circuit Breaker**|**Ampere**<br>**Rating**|**Number**<br>**of**|||**Federal**<br>**Spec.**|**Vac Ratings**|||**Vdc Ratings**2|||**Page**|
|**Type**|**Type Code**|**at 40°C**|**Poles**|**Vac**|**Vdc**|**W-C-375b**|**120**|**120/240**|**240**|**24–48**|**62.5**|**80**|**Number**|
|HQP|P|10–70|1|120/240|24, 48, 62.5|10a, 11a, 12a|—|10,000|—|5000|3|—|**V4-T1-6**|
|HQP|P|10–125|2|120/240|24, 48, 80|10a, 12a|—|10,000|—|5000|5000|5000|**V4-T1-6**|
|HQP|P|10–100|2, 3|240|—|10b, 11b, 12b|—|—|10,000|—|—|—|**V4-T1-6**|
|QPHW|P|15–70|1|120/240|24, 48, 62.5|14a|—|22,000|—|5000|3|—|**V4-T1-6**|
|QPHW|P|15–125|2|120/240|24, 48, 80|14a|—|22,000|—|5000|5000|5000|**V4-T1-6**|
|QPHW|P|15–100|2, 3|240|—|14b|—|—|22,000|—|—|—|**V4-T1-6**|
|QHPX|P|15–70|1|120/240|24, 48, 62.5|—|—|42,000|—|5000|3|—|**V4-T1-7**|
|QHPX|P|15–100|2|120/240|24, 48, 80|—|—|42,000|—|5000|5000|5000|**V4-T1-7**|
|QHPX|P|15–100|3|240|—|—|—|—|42,000|—|—|—|**V4-T1-7**|
|QHPW|P|15–30|1|120/240|24, 48, 62.5|15a|—|65,000|—|5000|3|—|**V4-T1-7**|
|QHPW|P|15–30|2|120/240|24, 48, 80|15a|—|65,000|—|5000|5000|5000|**V4-T1-7**|
|QHPW|P|15–20|3|240|—|15b|—|—|65,000|—|—|—|**V4-T1-7**|
|QPGFT|P, GF|15–40|1|120|—|10a, 11a, 12a|10,000|—|—|—|—|—|**V4-T1-9**|
|QPGFT|P, GF|15–50|2|120/240|—|10a, 11a, 12a|—|10,000|—|—|—|—|**V4-T1-9**|
## _**Notes**_
> 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
> 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL® listed.
> 3 62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Circuit Breaker Type Codes: **P** Plug-In; **B** Bolt-On; **C** Cable-In/Cable-Out; **GF** Ground Fault, 5 mA; **GFEP** Ground Fault, 30 mA.
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see **Pages V4-T1-31** to **V4-T1-36** .
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-2**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**Eaton’s QUICKLAG Industrial Circuit Breakers**[1] **Plug-In, Bolt-On, Cable-In/Cable-Out, continued**
|**Eaton’s**|**QUICKLAG In**|**dustrial Cir**|**cuit Brea**|**kers**1 **P**|**ug-In, Bolt**|**-On, Cable-I**|**n/Cable-Out, co**|**n/Cable-Out, co**|**ntinued**|**ntinued**|**ntinued**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Continuous**|||||**Interrupting Ratings**||**rms Symmetrical Amperes**|||||
|**Circuit**<br>**Breaker**|**Circuit Breaker**|**Ampere**<br>**Rating**|**Number**<br>**of**|||**Federal**<br>**Spec.**|**Vac Ratings**|||**Vdc Ratings**2|||**Page**|
|**Type**|**Type Code**|**at 40°C**|**Poles**|**Vac**|**Vdc**|**W-C-375b**|**120**|**120/240**|**240**|**24–48**|**62.5**|**80**|**Number**|
|QPHGFT|P, GF|15–30|1|120|—|10a, 11a, 12a|22,000|—|—|—|—|—|**V4-T1-9**|
|QPHGFT|P, GF|15–50|2|120/240|—|10a, 11a, 12a|—|22,000|—|—|—|—|**V4-T1-9**|
|QPGFEP|P, GFEP|15–40|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-9**|
|QPGFEP|P, GFEP|15–50|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-9**|
|QPHGFEP|P, GFEP|15–30|1|120|—|—|22,000|—|—|—|—|—|**V4-T1-9**|
|BABRSP|B|15–30|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-12**|
|BABRSP|B|15–30|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-12**|
|BRRP|P|15–30|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-32**|
|BRRP|P|15–30|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-32**|
|CLRP|P|15–30|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-32**|
|CLRP|P|15–30|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-32**|
|BAB|B|10–70|1|120/240|24, 48, 62.5|10a, 11a, 12a|—|10,000|—|5000|3|—|**V4-T1-12**|
|BAB|B|10–125|2|120/240|24, 48, 80|10a, 12a|—|10,000|—|5000|5000|5000|**V4-T1-12**|
|BAB|B|10–100|2, 3|240|—|10b, 11b, 12b|—|—|10,000|—|—|—|**V4-T1-12**|
|BABRP|B|15–30|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-32**|
|BABRP|B|15–30|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-32**|
|QBAF|B, AF|15–20|1, 2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-15**|
|QBCAF|B, AF, GF|15–20|1, 2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-15**|
|QBHW|B|15–70|1|120/240|24, 48, 62.5|14a|—|22,000|—|5000|3|—|**V4-T1-12**|
|QBHW|B|15–125|2|120/240|24, 48, 80|14a|—|22,000|—|5000|5000|5000|**V4-T1-12**|
|QBHW|B|15–100|2, 3|240|—|14b|—|—|22,000|—|—|—|**V4-T1-12**|
|HBAX|B|15–70|1|120/240|24, 48, 62.5|—|—|42,000|—|5000|3|—|**V4-T1-13**|
|HBAX|B|15–100|2|120/240|24, 48, 80|—|—|42,000|—|5000|5000|5000|**V4-T1-13**|
|HBAX|B|15–100|3|240||—|—|—|42,000|—|—|—|**V4-T1-13**|
|HBAW|B|15–30|1|120/240|24, 48, 62.5|15a|—|65,000|—|5000|3|—|**V4-T1-13**|
|HBAW|B|15–30|2|120/240|24, 48, 80|15a|—|65,000|—|5000|5000|5000|**V4-T1-13**|
|HBAW|B|15–20|3|240|—|15b|—|—|65,000|—|—|—|**V4-T1-13**|
|QBGFT|B, GF|15–40|1|120|—|10a, 11a, 12a|10,000|—|—|—|—|—|**V4-T1-18**|
|QBGFT|B, GF|15–50|2|120/240|—|10a, 11a, 12a|—|10,000|—|—|—|—|**V4-T1-18**|
|QBHGFT|B, GF|15–30|1|120|—|10a, 11a, 12a|22,000|—|—|—|—|—|**V4-T1-18**|
|QBHGFT|B, GF|15–30|1|120/240|—|10a, 11a, 12a|—|22,000|—|—|—|—|**V4-T1-18**|
|QBGFEP|B, GFEP|15–40|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-18**|
|QBGFEP|B, GFEP|15–50|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-18**|
|QBHGFEP|B, GFEP|15–30|1|120|—|—|22,000|—|—|—|—|—|**V4-T1-18**|
|QBHGFEP|B, GFEP|15–30|2|120/240|—|—|22,000|22,000|—|—|—|—|**V4-T1-18**|
|QC|C|10–70|1|120/240|24, 48, 62.5|10a, 11a, 12a|—|10,000|—|5000|3|—|**V4-T1-41**|
|QC|C|10–100|2|120/240|24, 48, 80|10a, 12a|—|10,000|—|5000|5000|5000|**V4-T1-41**|
|QC|C|10–100|2, 3, 4|240|—|10b, 11b, 12b|—|—|10,000|—|—|—|**V4-T1-41**|
|QCD|C|10–60|1, 2|120/240|24, 48, 62.5|—|10,000|10,000|—|3000|3000|—|**V4-T1-23**|
|QCD|C|10–100|2, 3|240|24, 48, 62.5|—|—|10,000|—|3000|3000|—|**V4-T1-23**|
|QCF|C|10–60|1, 2|120/240|24, 48, 62.5|—|10,000|10,000|—|3000|3000|—|**V4-T1-42**|
**1**
## _**Notes**_
> 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
> 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed.
> 3 62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Circuit Breaker Type Codes: **P** Plug-In; **B** Bolt-On; **C** Cable-In/Cable-Out; **GF** Ground Fault, 5 mA; **GFEP** Ground Fault, 30 mA. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see **Pages V4-T1-31** to **V4-T1-36** .
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-3**
Miniature Circuit Breakers and Supplementary Protectors
1.1
## Industrial Circuit Breakers
**1**
**Eaton’s QUICKLAG Industrial Circuit Breakers**[1] **Plug-In, Bolt-On, Cable-In/Cable-Out, continued**
|||**Continuous**|||||**Interrupting Ratings**|**Interrupting Ratings**|**rms Symmetrical Amperes**|**rms Symmetrical Amperes**|**rms Symmetrical Amperes**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Circuit**<br>**Breaker**|**Circuit**<br>**Breaker**|**Ampere**<br>**Rating**|**Number**<br>**of**|||**Federal**<br>**Spec.**|**Vac Ratings**|||**Vdc Ratings**2|||**Page**|
|**Type**|**Type Code**|**at 40°C**|**Poles**|**Vac**|**Vdc**|**W-C-375b**|**120**|**120/240**|**240**|**24–48**|**62.5**|**80**|**Number**|
|QCF|C|15–20|1, 2|120/240|24, 48, 62.5|—|22,000|—|—|3000|3000|—|**V4-T1-27**|
|QCF<br>QCR|C<br>C|15–30<br>10–60|2, 3<br>1, 2|240<br>120/240|24, 48, 62.5<br>24, 48, 62.5|—<br>—|—<br>10,000|10,000<br>10,000|—<br>—|3000<br>3000|3000<br>3000|—<br>—|**V4-T1-27**<br>**V4-T1-27**|
|QCR|C|15–20|1, 2|120/240|24, 48, 62.5|—|22,000|—|—|3000|3000|—|**V4-T1-27**|
|QCR|C|15–30|2, 3|240|24, 48, 62.5|—|—|10,000|—|3000|3000|—|**V4-T1-27**|
|QCHW|C|15–70|1|120/240|24, 48, 62.5|14a|—|22,000|—|5000|3|—|**V4-T1-22**|
|QCHW|C|15–100|2|120/240|24, 48, 80|14a|—|22,000|—|5000|5000|5000|**V4-T1-22**|
|QCHW|C|15–100|2, 3|240|—|14b|—|—|22,000|—|—|—|**V4-T1-22**|
|QHCX<br>QHCX|C<br>C|15–70<br>15–100|1<br>2|120/240<br>120/240|24, 48, 62.5<br>24, 48, 80|—<br>—|—<br>—|42,000<br>42,000|—<br>—|5000<br>5000|3<br>5000|—<br>5000|**V4-T1-22**<br>**V4-T1-22**|
|QHCX|C|15–100|3|240|—|—|—|—|42,000|—|—|—|**V4-T1-22**|
|QHCW|C|15–30|1|120/240|24, 48, 62.5|15a|—|65,000|—|5000|3|—|**V4-T1-22**|
|QHCW|C|15–30|2|120/240|24, 48, 80|15a|—|65,000|—|5000|5000|5000|**V4-T1-22**|
|QHCW|C|15–20|3|240|—|15b|—|—|65,000|—|—|—|**V4-T1-22**|
|QCGFT|C, GF|15–40|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-29**|
|QCGFT<br>QCHGFT|C, GF<br>C, GF|15–50<br>15–30|2<br>1|120/240<br>120|—<br>—|—<br>—|—<br>22,000|10,000<br>—|—<br>—|—<br>—|—<br>—|—<br>—|**V4-T1-29**<br>**V4-T1-29**|
|QCHGFT|C, GF|15–30|2|120/240|—|—|—|22,000|—|—|—|—|**V4-T1-29**|
|QCGFEP|C, GFEP|15–40|1|120|—|—|10,000|—|—|—|—|—|**V4-T1-29**|
|QCGFEP|C, GFEP|15–50|2|120/240|—|—|—|10,000|—|—|—|—|**V4-T1-29**|
|QCHGFEP<br>QCHGFEP|C, GFEP<br>C, GFEP|15–30<br>15–30|1<br>2|120<br>120/240|—<br>—|—<br>—|22,000<br>—|—<br>22,000|—<br>—|—<br>—|—<br>—|—<br>—|**V4-T1-29**<br>**V4-T1-29**|
## _**Notes**_
> 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
> 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed.
> 3 62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Circuit Breaker Type Codes: **P** Plug-In; **B** Bolt-On; **C** Cable-In/Cable-Out; **GF** Ground Fault, 5 mA; **GFEP** Ground Fault, 30 mA.
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see **Pages V4-T1-31** to **V4-T1-36** .
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-4**
1.1
Industrial Circuit Breakers
## Miniature Circuit Breakers and Supplementary Protectors
## **QUICKLAG Type HQP Single-Pole**
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**||**1**|
|**_Description_**|**_Page_**||
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|**1**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-6**|**1**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-7**||
|QUICKLAG Plug-On Ground Fault and Equipment<br>Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|**1**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types|**V4-T1-11**|**1**|
|QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Ground Fault and Equipment Protectors,|**V4-T1-14**|**1**|
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP. . . . . .|**V4-T1-17**||
|Cable-In/Cable-Out Types QC, QCD, QCHW,||**1**|
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**||
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,<br>QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|**1**|
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||**1**|
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . .|**V4-T1-31**|**1**|
|Solenoid Operator—Remote Controlled Latching for|||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . . .|**V4-T1-34**|**1**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**||
|Special Application Breakers, Types HQP, BA, QC. . . .|**V4-T1-40**|**1**|
## **QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW**
## **Product Description**
- All products 15–100A are HACR rated
- Switching duty rated for 120 Vac fluorescent light applications
## **Standards and Certifications**
- Built and listed to UL 489
- All products UL and CSA[®] listed
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-5**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1**
## **Product Selection**
## **QUICKLAG Type HQP Single-Pole**
## **QUICKLAG Type: HQP 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**240 Vac**|**Three-Pole**<br>**240 Vac**|
|---|---|---|---|---|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|10|**HQP1010**|**HQP2010**|**—**|**HQP3010H**3|
|15<br>20|**HQP1015**12<br>**HQP1020**12|**HQP2015**<br>**HQP2020**|**HQP2015H**<br>**HQP2020H**|**HQP3015H**<br>**HQP3020H**|
|25<br>**HQP1025**<br>**HQP2025**<br>**HQP2025H**<br>**HQP3025H**<br>30<br>**HQP1030**<br>**HQP2030**<br>**HQP2030H**<br>**HQP3030H**<br>35<br>**HQP1035**<br>**HQP2035**<br>**HQP2035H**<br>**HQP3035H**<br>40<br>**HQP1040**<br>**HQP2040**<br>**HQP2040H**<br>**HQP3040H**<br>~~a~~|||||
|45<br>50|**HQP1045**<br>**HQP1050**|**HQP2045**<br>**HQP2050**|**HQP2045H**<br>**HQP2050H**|**HQP3045H**<br>**HQP3050H**|
|55<br>60|**HQP1055**<br>**HQP1060**|**HQP2055**<br>**HQP2060**|**HQP2055H**<br>**HQP2060H**|**HQP3055H**<br>**HQP3060H**|
|70<br>80|**HQP1070**<br>**—**|**HQP2070**<br>**HQP2080**|**HQP2070H**<br>**HQP2080H**|**HQP3070H**<br>**HQP3080H**|
|90<br>100|**—**<br>**HQP1100**|**HQP2090**<br>**HQP2100**|**HQP2090H**<br>**HQP2100H**|**HQP3090H**<br>**HQP3100H**|
|110<br>125|**—**<br>**—**|**HQP2110**<br>**HQP2125**|**—**<br>**—**|**—**<br>**—**|
|150|**—**|**HQP2150**|**—**|**—**|
## **QUICKLAG Type: HQP Non-Automatic Switches**
|**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**240 Vac**|**Three-Pole**<br>**240 Vac**|
|---|---|---|---|---|
|**at 40°C**<br>50|**Catalog Number**<br>**HQP1050N**|**Catalog Number**<br>**—**|**Catalog Number**<br>**HQP2050N**|**Catalog Number**<br>**HQP3050N**|
|60<br>100|**HQP1060N**<br>**HQP1100N**|**—**<br>**—**|**HQP2060N**<br>**HQP2100N**|**HQP3060N**<br>**HQP3100N**|
## **QUICKLAG Type: QPHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**120/240 Vac**<br>**Catalog Number**|**120/240 Vac**<br>**Catalog Number**|**240 Vac**<br>**Catalog Number**|**240 Vac**<br>**Catalog Number**|
|15<br>20|**QPHW1015**1<br>**QPHW1020**1|**QPHW2015**<br>**QPHW2020**|**QPHW2015H**<br>**QPHW2020H**|**QPHW3015H**<br>**QPHW3020H**|
|25<br>30|**QPHW1025**<br>**QPHW1030**|**QPHW2025**<br>**QPHW2030**|**QPHW2025H**<br>**QPHW2030H**|**QPHW3025H**<br>**QPHW3030H**|
|35<br>40|**QPHW1035**<br>**QPHW1040**|**QPHW2035**<br>**QPHW2040**|**QPHW2035H**<br>**QPHW2040H**|**QPHW3035H**<br>**QPHW3040H**|
|45<br>50|**QPHW1045**<br>**QPHW1050**|**QPHW2045**<br>**QPHW2050**|**QPHW2045H**<br>**QPHW2050H**|**QPHW3045H**<br>**QPHW3050H**|
|55<br>60|**QPHW1055**<br>**QPHW1060**|**QPHW2055**<br>**QPHW2060**|**QPHW2055H**<br>**QPHW2060H**|**QPHW3055H**<br>**QPHW3060H**|
|70|**QPHW1070**|**QPHW2070**|**QPHW2070H**|**QPHW3070H**|
|80|**—**|**QPHW2080**|**QPHW2080H**|**QPHW3080H**|
|90|**—**|**QPHW2090**|**QPHW2090H**|**QPHW3090H**|
|100|**—**|**QPHW2100**|**QPHW2100H**|**QPHW3100H**|
|110|**—**|**QPHW2110**|**—**|**—**|
|125|**—**|**QPHW2125**|**—**|**—**|
## _**Notes**_
1 Switching duty rated for 120 Vac fluorescent light applications.
> 2 For special low-magnetic breaker, order **HQP1015L1** or **HQP1020L1** .
3 Not UL listed.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-6**
Industrial Circuit Breakers
## Miniature Circuit Breakers and Supplementary Protectors
## 1.1
**QUICKLAG Type: QHPX 42,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**QHPX1015**1|**QHPX2015**|**—**|**QHPX3015H**|
|20|**QHPX1020**1|**QHPX2020**|**—**|**QHPX3020H**|
|25|**QHPX1025**|**QHPX2025**|**—**|**QHPX3025H**|
|30|**QHPX1030**|**QHPX2030**|**—**|**QHPX3030H**|
|35|**QHPX1035**|**QHPX2035**|**—**|**QHPX3035H**|
|40|**QHPX1040**|**QHPX2040**|**—**|**QHPX3040H**|
|45|**QHPX1045**|**QHPX2045**|**—**|**QHPX3045H**|
|50|**QHPX1050**|**QHPX2050**|**—**|**QHPX3050H**|
|55|**QHPX1055**|**QHPX2055**|**—**|**QHPX3055H**|
|60|**QHPX1060**|**QHPX2060**|**—**|**QHPX3060H**|
|70|**QHPX1070**|**QHPX2070**|**—**|**QHPX3070H**|
|80|**—**|**QHPX2080**|**—**|**QHPX3080H**|
|90|**—**|**QHPX2090**|**—**|**QHPX3090H**|
|100|**—**|**QHPX2100**|**—**|**QHPX3100H**|
**1**
## **QUICKLAG Type: QHPW 65,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**QHPW1015**1|**QHPW2015**|**—**|**QHPW3015H**|
|20|**QHPW1020**1|**QHPW2020**|**—**|**QHPW3020H**|
|25|**QHPW1025**|**QHPW2025**|**—**|**—**|
|30|**QHPW1030**|**QHPW2030**|**—**|**—**|
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Number**|**Carton**|**Approximate**||
|---|---|---|---|
|**of Poles**|**Quantity**|**Weight Lbs (kg)**|**Dimensions**|
|1|24|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|2|12|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|3|8|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
## _**Note**_
> 1 Switching duty rated for 120 Vac fluorescent light applications.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-7**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## ~~Mi~~ **1 QUICKLAG Type QPGFT Single-PoleGround Fault Circuit Breaker**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .<br>Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-9**<br>**V4-T1-10**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-10**<br>**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types<br>QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,|**V4-T1-20**|
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Cable-In/Cable-Out Ground Fault and Equipment|**V4-T1-24**|
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**<br>Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC<br>Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-37**<br>**V4-T1-40**|
## **QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP**
## **Product Description**
## **Standards and Certifications**
- Built and listed to UL 489
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- 5 mA trip sensitivity
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- Built and tested to UL 943
## _**QUICKLAG Ground Fault Equipment Protectors**_
- 30 mA trip sensitivity
## _**QUICKLAG Ground Fault Equipment Protectors**_
- Built and listed to UL 1053
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-8**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
## **Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type: QUICKLAG Type QPGFT Single-Pole QPGFT 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QPGFT1015**|**QPGFT2015**|
|20|**QPGFT1020**|**QPGFT2020**|
|25|**QPGFT1025**|**QPGFT2025**|
|30|**QPGFT1030**|**QPGFT2030**|
|40|**QPGFT1040**|**QPGFT2040**|
|50|**—**|**QPGFT2050**|
## **QUICKLAG Type: QPHGFT 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QPHGF1015**|**QPHGF2015**|
|20|**QPHGF1020**|**QPHGF2020**|
|25|**QPHGF1025**|**QPHGF2025**|
|30|**QPHGF1030**|**QPHGF2030**|
## **Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type: QPGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QPGFEP1015**|**QPGFEP2015**|
|20|**QPGFEP1020**|**QPGFEP2020**|
|25|**QPGFEP1025**|**QPGFEP2025**|
|30|**QPGFEP1030**|**QPGFEP2030**|
|40|**QPGFEP1040**|**QPGFEP2040**|
|50|**—**|**QPGFEP2050**|
## **QUICKLAG Type: QPHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QPHGFEP1015**|**QPHGFEP2015**|
|20|**QPHGFEP1020**|**QPHGFEP2020**|
|25|**QPHGFEP1025**|**QPHGFEP2025**|
|30|**QPHGFEP1030**|**QPHGFEP2030**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-9**
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
## 1.1
**Special Application Ground Fault Circuit Protectors—5 mA Sensitivity 1 QUICKLAG Type: QPGFT 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**120 Vac**<br>**Catalog Number**|**120/240 Vac**<br>**Catalog Number**|
|15<br>20|**QPGFT1015W1**<br>**QPGFT1020W1**|**QPGFT2015W1**<br>**QPGFT2020W1**|
|25<br>30|**QPGFT1025W1**<br>**QPGFT1030W1**|**QPGFT2025W1**<br>**QPGFT2030W1**|
|40<br>50|**—**<br>**—**|**QPGFT2040W1**<br>**QPGFT2050W1**|
|15|**QPGFT1015W2**|**—**|
|20|**QPGFT1020W2**|**—**|
|25|**QPGFT1025W2**|**—**|
|30|**QPGFT1030W2**|**—**|
**Special Application Ground Fault Circuit Protectors—30 mA Sensitivity QUICKLAG Type: QPGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**120 Vac**<br>**Catalog Number**|**120/240 Vac**<br>**Catalog Number**|
|15|**QPGFEP1015W1**|**QPGFEP2015W1**|
|20|**QPGFEP1020W1**|**QPGFEP2020W1**|
|25|**QPGFEP1025W1**|**QPGFEP2025W1**|
|30|**QPGFEP1030W1**|**QPGFEP2030W1**|
|40<br>50|**—**<br>**—**|**QPGFEP2040W1**<br>**QPGFEP2050W1**|
|15|**QPGFEP1015W2**|—|
|20|**QPGFEP1020W2**|—|
|25|**QPGFEP1025W2**|—|
|30|**QPGFEP1030W2**|—|
## **Wiring Diagram**
**Bell Alarm and Auxiliary Contact Schematic**
|Ground<br>Fault<br>Breaker|Blue Wire<br>Red Wire<br>Black Wire<br>Blue<br>Red<br>NC<br>NO|
|---|---|
||NC|
||Red<br>NO|
Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)—contacts change state when breaker trips. Auxiliary Switch (W2)—contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided.
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Number**|**Carton**|**Approximate**||
|---|---|---|---|
|**of Poles**<br>1|**Quantity**<br>24|**Weight Lbs (kg)**<br>11.00 (5.0)|**Dimensions**<br>12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)|
|2|5|5.00 (2.3)|15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3)|
_**Note**_
Shipped individually or in carton quantities.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-10**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **QUICKLAG Type BAB Single-Pole**
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**||**1**|
|**_Description_**|**_Page_**||
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|**1**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**||
|QUICKLAG Plug-On Ground Fault and Equipment||**1**|
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**||
|Bolt-On Types BAB, QBHW, HBAX, HBAW<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-12**|**1**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types|**V4-T1-13**|**1**|
|QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Ground Fault and Equipment Protectors,|**V4-T1-14**|**1**|
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP. . . . . .|**V4-T1-17**||
|Cable-In/Cable-Out Types QC, QCD, QCHW,||**1**|
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**||
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,<br>QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|**1**|
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||**1**|
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . .|**V4-T1-31**|**1**|
|Solenoid Operator—Remote Controlled Latching for|||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . . .|**V4-T1-34**|**1**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**||
|Special Application Breakers, Types HQP, BA, QC. . . .|**V4-T1-40**|**1**|
## **Bolt-On Types BAB, QBHW, HBAX, HBAW**
## **Standards and Certifications**
## **Product Description**
- All products 15–100A are HACR rated
- Built and listed to UL 489
- All products UL and
- ● Switching duty rated CSA listed for 120 Vac fluorescent light applications
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-11**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1** ~~—__~~
## **Product Selection**
## **QUICKLAG Type: BA 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
## **QUICKLAG Type BAB Single-Pole**
|**Single-Pole**||||||
|---|---|---|---|---|---|
|**Single-Pole**|**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**240 Vac**|**Three-Pole**<br>**240 Vac**|
||**at 40°C**<br>**Catalog Number**<br>**Catalog Number**<br>10<br>**BAB1010**<br>**BAB2010**<br>15<br>**BAB1015**12<br>**BAB2015**<br>20<br>**BAB1020**12<br>**BAB2020**<br>~~ee~~|||**Catalog Number**<br>**Catalog Number**<br>**BAB2010H**3<br>**BAB3010H**3<br>**BAB2015H**<br>**BAB3015H**<br>**BAB2020H**<br>**BAB3020H**<br>~~——-—-==~~||
||25<br>30|**BAB1025**<br>**BAB1030**|**BAB2025**<br>**BAB2030**|**BAB2025H**<br>**BAB2030H**|**BAB3025H**<br>**BAB3030H**|
|35<br>**BAB1035**<br>**BAB2035**<br>**BAB2035H**<br>**BAB3035H**<br>40<br>**BAB1040**<br>**BAB2040**<br>**BAB2040H**<br>**BAB3040H**<br>45<br>**BAB1045**<br>**BAB2045**<br>**BAB2045H**<br>**BAB3045H**<br>50<br>**BAB1050**<br>**BAB2050**<br>**BAB2050H**<br>**BAB3050H**<br>~~FO~~||||||
||55<br>60|**BAB1055**<br>**BAB1060**|**BAB2055**<br>**BAB2060**|**BAB2055H**<br>**BAB2060H**|**BAB3055H**<br>**BAB3060H**|
||70<br>80|**BAB1070**<br>**—**|**BAB2070**<br>**BAB2080**|**BAB2070H**<br>**BAB2080H**|**BAB3070H**<br>**BAB3080H**|
||90<br>100|**—**<br>**BAB1100**|**BAB2090**<br>**BAB2100**|**BAB2090H**<br>**BAB2100H**|**BAB3090H**<br>**BAB3100H**|
||110<br>125|**—**<br>**—**|**BAB2110**<br>**BAB2125**|**—**<br>**—**|**—**<br>**—**|
## **QUICKLAG Type: BA Non-Automatic Switches**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**120/240 Vac**<br>**Catalog Number**|**120/240 Vac**<br>**Catalog Number**|**240 Vac**<br>**Catalog Number**|**240 Vac**<br>**Catalog Number**|
|50<br>60|**BAB1050N**<br>**BAB1060N**|**—**<br>**—**|**BAB2050N**<br>**BAB2060N**|**BAB3050N**<br>**BAB3060N**|
|100|**BAB1100N**|**—**|**BAB2100N**|**BAB3100N**|
## **QUICKLAG Type: QBHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**240 Vac**|**Three-Pole**<br>**240 Vac**|
|---|---|---|---|---|
|**at 40°C**<br>15|**Catalog Number**<br>**QBHW1015**1|**Catalog Number**<br>**QBHW2015**|**Catalog Number**<br>**QBHW2015H**|**Catalog Number**<br>**QBHW3015H**|
|20<br>25|**QBHW1020**1<br>**QBHW1025**|**QBHW2020**<br>**QBHW2025**|**QBHW2020H**<br>**QBHW2025H**|**QBHW3020H**<br>**QBHW3025H**|
|30<br>35|**QBHW1030**<br>**QBHW1035**|**QBHW2030**<br>**QBHW2035**|**QBHW2030H**<br>**QBHW2035H**|**QBHW3030H**<br>**QBHW3035H**|
|40<br>45|**QBHW1040**<br>**QBHW1045**|**QBHW2040**<br>**QBHW2045**|**QBHW2040H**<br>**QBHW2045H**|**QBHW3040H**<br>**QBHW3045H**|
|50<br>55|**QBHW1050**<br>**QBHW1055**|**QBHW2050**<br>**QBHW2055**|**QBHW2050H**<br>**QBHW2055H**|**QBHW3050H**<br>**QBHW3055H**|
|60<br>70|**QBHW1060**<br>**QBHW1070**|**QBHW2060**<br>**QBHW2070**|**QBHW2060H**<br>**QBHW2070H**|**QBHW3060H**<br>**QBHW3070H**|
|80|**—**|**QBHW2080**|**QBHW2080H**|**QBHW3080H**|
|90|**—**|**QBHW2090**|**QBHW2090H**|**QBHW3090H**|
|100|**—**|**QBHW2100**|**QBHW2100H**|**QBHW3100H**|
|110|**—**|**QBHW2110**|**—**|**—**|
|125|**—**|**QBHW2125**|**—**|**—**|
## _**Notes**_
1 Switching duty rated for 120 Vac fluorescent light applications.
> 2 For special low-magnetic breaker, order **BAB1015L1** or **BAB1020L1** .
3 Not UL listed.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-12**
1.1
Industrial Circuit Breakers
**1**
## Miniature Circuit Breakers and Supplementary Protectors
**QUICKLAG Type: HBAX 42,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**HBAX1015**1|**HBAX2015**|**—**|**HBAX3015H**|
|20|**HBAX1020**1|**HBAX2020**|**—**|**HBAX3020H**|
|25|**HBAX1025**|**HBAX2025**|**—**|**HBAX3025H**|
|30|**HBAX1030**|**HBAX2030**|**—**|**HBAX3030H**|
|35|**HBAX1035**|**HBAX2035**|**—**|**HBAX3035H**|
|40|**HBAX1040**|**HBAX2040**|**—**|**HBAX3040H**|
|45|**HBAX1045**|**HBAX2045**|**—**|**HBAX3045H**|
|50|**HBAX1050**|**HBAX2050**|**—**|**HBAX3050H**|
|55|**HBAX1055**|**HBAX2055**|**—**|**HBAX3055H**|
|60|**HBAX1060**|**HBAX2060**|**—**|**HBAX3060H**|
|70|**HBAX1070**|**HBAX2070**|**—**|**HBAX3070H**|
|80|**—**|**HBAX2080**|**—**|**HBAX3080H**|
|80|**—**|**HBAX2080**|**—**|**HBAX3080H**|
|90|**—**|**HBAX2090**|**—**|**HBAX3090H**|
|100|**—**|**HBAX2100**|**—**|**HBAX3100H**|
## **QUICKLAG Type: HBAW 65,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**HBAW1015**1|**HBAW2015**|**—**|**HBAW3015H**|
|20|**HBAW1020**1|**HBAW2020**|**—**|**HBAW3020H**|
|25|**HBAW1025**|**HBAW2025**|**—**|**—**|
|30|**HBAW1030**|**HBAW2030**|**—**|**—**|
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Number**|**Carton**|**Approximate**||
|---|---|---|---|
|**of Poles**|**Quantity**|**Weight Lbs (kg)**|**Dimensions**|
|1|24|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|2|12|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|3|8|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
## _**Note**_
> 1 Switching duty rated for 120 Vac fluorescent light applications.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-13**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1** ~~I~~
## **Bolt-On Arc Fault Circuit Interrupter QUICKLAG Types QBAF, QBCAF**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**<br>Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**_Page_**<br>**V4-T1-2**<br>**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types|**V4-T1-11**|
|QBAF, QBCAF<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-15**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Ground Fault and Equipment Protectors,|**V4-T1-16**|
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,<br>QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-40**|
## **Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF**
## **Product Description**
- All products HACR rated
## **Features, Benefits and Functions**
- 10 and 22 kAIC rating at 120V and 120/240V
## **Standards and Certifications**
- Built and listed to UL 489
- UL File E7819 for QBAF
- Single-pole AFCI
- HID ratings for HID (High Intensity Discharge) lighting
- All models are HACR rated
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-14**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
## _**QBCAF and QBAF Type AFCIs**_
Effective immediately, Eaton AFCIs are available for use in Sumter panels with a 22 kAIC rating. This higher rated breaker will allow us to win jobs where AFCIs are specified at higher than 10 kAIC. This breaker provides standard thermal-
magnetic protection of
branch circuits. This product will have the same form, fit and function of the current bolt-on AFCI (QBCAF and QBAF Type). Product scope is below. These breakers are in Bid Manager™ for Pow-RLine 1a, Pow-R-Line 1a-LX,
Pow-R-Line 3a and Pow-RLine 4a panelboards. For series rated combinations, continue to use the less expensive 10 kAIC QBCAF and QBAF offerings.
Breakers can also be ordered from Vista.
## **1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**
|**QBHCAF**|**1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**|**1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**|**1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**|**1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**|**1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter**|
|---|---|---|---|---|---|
|||**kAIC**|**Ampere**|||
||**Poles**|**Rating**|**Rating**|**Configuration**|**Catalog Number**|
||**Type QBCAF Combination AFCI**|**Type QBCAF Combination AFCI**||||
||Single-pole|10 kAIC|15|Combination AFCI|**QBCAF1015**|
||||20|Combination AFCI|**QBCAF1020**|
|||22 kAIC|15|Combination AFCI|**QBHCAF1015**|
||||20|Combination AFCI|**QBHCAF1020**|
||**Type QBAF Branch Feeder AFCI**|||||
||Single-pole|10 kAIC|15|Branch Feeder AFCI|**QBAF1015**|
||||20|Branch Feeder AFCI|**QBAF1020**|
|||22 kAIC|15|Branch Feeder AFCI|**QBHAF1015**|
||||20|Branch Feeder AFCI|**QBHAF1020**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-15**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Wiring Diagrams**
## **Single-Pole 120V Load Application Sourced by 120/240 Vac**
**==> picture [194 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
120/240 Vac<br>Source<br>N A B<br>Line B<br>Single-Pole<br>Neutral<br>120V<br>Neutral Duplex<br>Receptacle<br>Equipment Ground<br>**----- End of picture text -----**<br>
## **Single-Pole Shared Neutral with Multi-Duplex Receptacle Application**
**==> picture [194 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
120/240 Vac<br>Source<br>N A B<br>Line B<br>Two-Pole<br>Neutral Two 120V<br>Duplex<br>Neutral Receptacles<br>Line A<br>Equipment Ground<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-16**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **QUICKLAG Type QBGFT Single-Pole Ground Fault Circuit Breaker**
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**||**1**|
|**_Description_**|**_Page_**||
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|**1**|
|QUICKLAG Plug-On Ground Fault and Equipment|||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|**1**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . .|**V4-T1-11**||
|Bolt-On Arc Fault Circuit Interrupter Types<br>QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|**1**|
|Bolt-On Ground Fault and Equipment Protectors,<br>Types QBGFT, QBHGFT, QBGFEP, QBHGFEP||**1**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-18**||
|Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-19**|**1**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-19**||
|Cable-In/Cable-Out Types QC, QCD, QCHW,||**1**|
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**||
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,<br>QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|**1**|
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||**1**|
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . .|**V4-T1-31**|**1**|
|Solenoid Operator—Remote Controlled Latching for|||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . . .|**V4-T1-34**|**1**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**||
|Special Application Breakers, Types HQP, BA, QC. . . .|**V4-T1-40**|**1**|
## **Bolt-On Ground Fault and Equipment Protectors, Types QBGFT, QBHGFT, QBGFEP, QBHGFEP**
## **Product Description**
## **Standards and Certifications**
- Built and tested to UL 489
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- 5 mA trip sensitivity
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- Built and tested to UL 943
## _**QUICKLAG Ground Fault Equipment Protectors**_
- 30 mA trip sensitivity
## _**QUICKLAG Ground Fault Equipment Protectors**_
- Built and tested to UL 1053
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-17**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1**
## **Product Selection**
## **QUICKLAG Type QBGFT Single-Pole**
## **Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type: QBGFT 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**120 Vac**<br>**Catalog Number**|**120/240 Vac**<br>**Catalog Number**|
|~~Se~~|||
|15|**QBGFT1015**|**QBGFT2015**|
|20<br>**QBGFT1020**<br>**QBGFT2020**<br>~~I~~|||
|25|**QBGFT1025**|**QBGFT2025**|
|~~es~~|||
|30|**QBGFT1030**|**QBGFT2030**|
|40|**QBGFT1040**|**QBGFT2040**|
|50|**—**|**QBGFT2050**|
## **QUICKLAG Type: QBHGFT 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**<br>15<br>~~SS~~|**120 Vac**<br>**Catalog Number**<br>**QBHGF1015**|**120/240 Vac**<br>**Catalog Number**<br>**QBHGF2015**|
|20|**QBHGF1020**|**QBHGF2020**|
|25|**QBHGF1025**|**QBHGF2025**|
|30|**QBHGF1030**|**QBHGF2030**|
## **Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type: QBGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**<br>15<br>20<br>~~SS~~|**120 Vac**<br>**Catalog Number**<br>**QBGFEP1015**<br>**QBGFEP1020**|**120/240 Vac**<br>**Catalog Number**<br>**QBGFEP2015**<br>**QBGFEP2020**|
|25|**QBGFEP1025**|**QBGFEP2025**|
|30|**QBGFEP1030**|**QBGFEP2030**|
|40|**QBGFEP1040**|**QBGFEP2040**|
|50|**—**|**QBGFEP2050**|
## **QUICKLAG Type: QBHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**<br>**at 40°C**<br>15<br>~~ee~~|**120 Vac**<br>**Catalog Number**<br>**QBHGFEP1015**<br>~~ee~~|**120/240 Vac**<br>**Catalog Number**<br>**QBHGFEP2015**<br>~~ee~~|
|20|**QBHGFEP1020**|**QBHGFEP2020**|
|25|**QBHGFEP1025**|**QBHGFEP2025**|
|30|**QBHGFEP1030**|**QBHGFEP2030**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-18**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**Special Application Ground Fault Circuit Protectors—5 mA Sensitivity QUICKLAG Type: QBGFT 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)**
**1**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QBGFT1015W1**|**QBGFT2015W1**|
|20|**QBGFT1020W1**|**QBGFT2020W1**|
|25|**QBGFT1025W1**|**QBGFT2025W1**|
|30|**QBGFT1030W1**|**QBGFT2030W1**|
|40|**—**|**QBGFT2040W1**|
|50|**—**|**QBGFT2050W1**|
|15|**QBGFT1015W2**|**—**|
|20|**QBGFT1020W2**|**—**|
|25|**QBGFT1025W2**|**—**|
|30|**QBGFT1030W2**|**—**|
**Special Application Ground Fault Circuit Protectors—30 mA Sensitivity QUICKLAG Type: QBGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)**
|**Continuous**|**Single-Pole**|**Two-Pole**|
|---|---|---|
|**Ampere Rating**|**120 Vac**|**120/240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|
|15|**QBGFEP1015W1**|**QBGFEP2015W1**|
|20|**QBGFEP1020W1**|**QBGFEP2020W1**|
|25|**QBGFEP1025W1**|**QBGFEP2025W1**|
|30|**QBGFEP1030W1**|**QBGFEP2030W1**|
|40|**—**|**QBGFEP2040W1**|
|50|**—**|**QBGFEP2050W1**|
|15|**QBGFEP1015W2**|—|
|20|**QBGFEP1020W2**|—|
|25|**QBGFEP1025W2**|—|
|30|**QBGFEP1030W2**|—|
## **Wiring Diagram**
## **Bell Alarm and Auxiliary Contact Schematic**
|Ground<br>Fault<br>Breaker|Blue Wire<br>Red Wire<br>Black Wire<br>Blue<br>Red<br>NC<br>NO|
|---|---|
||NC|
||Red<br>NO|
Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)—contacts change state when breaker trips. Auxiliary Switch (W2)—contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided.
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Shipping Data**|||
|---|---|---|
|**Number of Poles**|**Approximate Weight Lbs (kg)**|**Dimensions**|
|1|11.00 (5.0)|12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)|
|2|5.00 (2.3)|15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3)|
## _**Note**_
Shipped individually or in carton quantities.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-19**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **QUICKLAG Type QC Single-Pole**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types||
|QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-21**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-23**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|
|Cable-In/Cable-Out Ground Fault and Equipment||
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||
|Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-40**|
## **Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW**
## **Product Description**
- All products 10–100A are HACR rated
- Switching duty rated for 120 Vac fluorescent light applications only
## **Standards and Certifications**
- Built and listed to UL 489
- All products UL and CSA listed
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-20**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
**QUICKLAG Type QC Single-Pole**
## **QUICKLAG Type: QC 10,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**<br>**Ampere Rating**<br>**at 40°C**<br>5<br>10<br>15<br>20<br>25<br>30<br>35|**Continuous**<br>**Ampere Rating**<br>**at 40°C**<br>5<br>10<br>15<br>20<br>25<br>30<br>35|**Single-Pole**<br>**120/240 Vac**<br>**Catalog Number**<br>**QC1005**1<br>**QC1010**<br>**QC1015**2<br>**QC1020**2<br>**QC1025**<br>**QC1030**<br>**QC1035**|**Two-Pole**<br>**120/240 Vac**<br>**Catalog Number**<br>**QC2005**1<br>**QC2010**<br>**QC2015**<br>**QC2020**<br>**QC2025**<br>**QC2030**<br>**QC2035**|**Two-Pole**<br>**240 Vac**<br>**Catalog Number**<br>**—**<br>**QC2010H**1<br>**QC2015H**<br>**QC2020H**<br>**QC2025H**<br>**QC2030H**<br>**QC2035H**|**Three-Pole**<br>**240 Vac**<br>**Catalog Number**<br>**—**<br>**QC3010H**1<br>**QC3015H**<br>**QC3020H**<br>**QC3025H**<br>**QC3030H**<br>**QC3035H**|**Four-Pole**<br>**240 Vac**<br>**Catalog Number**<br>**—**<br>**—**<br>**QC4015H**<br>**QC4020H**<br>**QC4025H**<br>**QC4030H**<br>**QC4035H**|
|---|---|---|---|---|---|---|
||40|**QC1040**|**QC2040**|**QC2040H**|**QC3040H**|**QC4040H**|
||45|**QC1045**|**QC2045**|**QC2045H**|**QC3045H**|**QC4045H**|
||50|**QC1050**|**QC2050**|**QC2050H**|**QC3050H**|**QC4050H**|
||55|**QC1055**|**QC2055**|**QC2055H**|**QC3055H**|**QC4055H**|
||60|**QC1060**|**QC2060**|**QC2060H**|**QC3060H**|**QC4060H**|
||70|**QC1070**|**QC2070**|**QC2070H**|**QC3070H**|**QC4070H**|
||70|**—**|**QC2080**|**QC2080H**|**QC3080H**|**QC4080H**|
||90|**—**|**QC2090**|**QC2090H**|**QC3090H**|**QC4090H**|
||100|**QC1100**|**QC2100**|**QC2100H**|**QC3100H**|**QC4100H**|
## **QUICKLAG Type: QC Non-Automatic Switches**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|**Four-Pole**|
|---|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|50|**QC1050N**|**—**|**QC2050N**|**QC3050N**|**—**|
|60|**QC1060N**|**—**|**QC2060N**|**QC3060N**|**—**|
|100|**QC1100N**|**—**|**QC2100N**|**QC3100N**|**—**|
## _**Notes**_
1 Not UL listed.
2 Switching duty rated for 120 Vac fluorescent light applications only.
For special low-magnetic breaker, order **QC1015L1** or **QC1020L1** .Non-automatic switches, see **Page V4-T1-42.**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-21**
Miniature Circuit Breakers and Supplementary Protectors
1.1
## Industrial Circuit Breakers
## **1**
## **QUICKLAG Type: QCHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|**Four-Pole**|
|---|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**QCHW1015**1|**QCHW2015**|**QCHW2015H**|**QCHW3015H**|**QCHW4015H**|
|20|**QCHW1020**1|**QCHW2020**|**QCHW2020H**|**QCHW3020H**|**QCHW4020H**|
|25|**QCHW1025**|**QCHW2025**|**QCHW2025H**|**QCHW3025H**|**QCHW4025H**|
|30|**QCHW1030**|**QCHW2030**|**QCHW2030H**|**QCHW3030H**|**QCHW4030H**|
|35|**QCHW1035**|**QCHW2035**|**QCHW2035H**|**QCHW3035H**|**QCHW4035H**|
|40|**QCHW1040**|**QCHW2040**|**QCHW2040H**|**QCHW3040H**|**QCHW4040H**|
|45|**QCHW1045**|**QCHW2045**|**QCHW2045H**|**QCHW3045H**|**QCHW4045H**|
|50|**QCHW1050**|**QCHW2050**|**QCHW2050H**|**QCHW3050H**|**QCHW4050H**|
|55|**QCHW1055**|**QCHW2055**|**QCHW2055H**|**QCHW3055H**|**QCHW4055H**|
|60|**QCHW1060**|**QCHW2060**|**QCHW2060H**|**QCHW3060H**|**QCHW4060H**|
|70|**QCHW1070**|**QCHW2070**|**QCHW2070H**|**QCHW3070H**|**QCHW4070H**|
|70|**—**|**QCHW2080**|**QCHW2080H**|**QCHW3080H**|**QCHW4080H**|
|90|**—**|**QCHW2090**|**QCHW2090H**|**QCHW3090H**|**QCHW4090H**|
|100|**—**|**QCHW2100**|**QCHW2100H**|**QCHW3100H**|**QCHW4100H**|
## **QUICKLAG Type: QHCX 42,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|**Four-Pole**|
|---|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**QHCX1015**1|**QHCX2015**|**—**|**QHCX3015H**|**—**|
|20|**QHCX1020**1|**QHCX2020**|**—**|**QHCX3020H**|**—**|
|25|**QHCX1025**|**QHCX2025**|**—**|**QHCX3025H**|**—**|
|30|**QHCX1030**|**QHCX2030**|**—**|**QHCX3030H**|**—**|
|35|**QHCX1035**|**QHCX2035**|**—**|**QHCX3035H**|**—**|
|40|**QHCX1040**|**QHCX2040**|**—**|**QHCX3040H**|**—**|
|45|**QHCX1045**|**QHCX2045**|**—**|**QHCX3045H**|**—**|
|50|**QHCX1050**|**QHCX2050**|**—**|**QHCX3050H**|**—**|
|55|**QHCX1055**|**QHCX2055**|**—**|**QHCX3055H**|**—**|
|60|**QHCX1060**|**QHCX2060**|**—**|**QHCX3060H**|**—**|
|70|**QHCX1070**|**QHCX2070**|**—**|**QHCX3070H**|**—**|
|70|**—**|**QHCX2080**|**—**|**QHCX3080H**|**—**|
|90|**—**|**QHCX2090**|**—**|**QHCX3090H**|**—**|
|100|**—**|**QHCX2100**|**—**|**QHCX3100H**|**—**|
## **QUICKLAG Type: QHCW 65,000A Interrupting Capacity Thermal-Magnetic Breakers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|**Four-Pole**|
|---|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|15|**QHCW1015**1|**QHCW2015**|**—**|**QHCW3015H**|**—**|
|20|**QHCW1020**1|**QHCW2020**|**—**|**QHCW3020H**|**—**|
|25|**QHCW1025**|**QHCW2025**|**—**|**—**|**—**|
|30|**QHCW1030**|**QHCW2030**|**—**|**—**|**—**|
## _**Notes**_
1 Switching duty rated for 120 Vac fluorescent light applications only. Non-automatic switches, see **Page V4-T1-42.**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-22**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## _**QUICKLAG Type QCD Miniature Circuit Breakers**_
- QCD breakers are used ● Flexible power feed primarily in HVAC and connection: industrial applications. wire size, position
- Single-, two- and three-pole options
- Same breaker size for entire rating range
- Modular construction
- Modular construction ● Field mountable DIN mounted accessories: (symmetrical rail 35 x finger shroud proof, quick 7.5 DIN/EN 50 022) connect terminals
- DIN mounted (symmetrical rail 35 x
- QCD same profile as ● Other accessories: Type QCR jumper unit
|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**<br>**QUICKLAG Type QCD**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**<br>**QUICKLAG Type QCD**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**<br>**QUICKLAG Type QCD**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|**QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|
|---|---|---|---|---|---|---|
|**Miniature Circuit**<br>**Breaker**||**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|||**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|||**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|||10|**QCD1010**|**QCD2010**|**—**|**—**|
|||15|**QCD1015**|**QCD2015**|**QCD2015H**|**QCD3015H**|
|||20|**QCD1020**|**QCD2020**|**QCD2020H**|**QCD3020H**|
|||25|**QCD1025**|**QCD2025**|**QCD2025H**|**QCD3025H**|
|||30|**QCD1030**|**QCD2030**|**QCD2030H**|**QCD3030H**|
|||35|**QCD1035**|**QCD2035**|**QCD2035H**|**QCD3035H**|
|||40|**QCD1040**|**QCD2040**|**QCD2040H**|**QCD3040H**|
|||45|**QCD1045**|**QCD2045**|**QCD2045H**|**QCD3045H**|
|||50|**QCD1050**|**QCD2050**|**QCD2050H**|**QCD3050H**|
|||55|**QCD1055**|**QCD2055**|**QCD2055H**|**QCD3055H**|
|||60|**QCD1060**|**QCD2060**|**QCD2060H**|**QCD3060H**|
|||70|**—**|**QCD2070**|**QCD2070H**|**QCD3070H**|
|||80|**—**|**QCD2080**|**QCD2080H**|**QCD3080H**|
|||90|**—**|**QCD2090**|**QCD2090H**|**QCD3090H**|
|||100|**—**|**QCD2090**|**QCD2090H**|**QCD3100H**|
||||**—**|**QCD2100**|**QCD2100H**|**—**|
## **QUICKLAG Type QCD Non-Automatic Switches**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|60|**—**|**—**|**QCD2060NA**|**—**|
|100|**—**|**—**|**—**|**—**|
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Number**|**Carton**|**Approximate**||
|---|---|---|---|
|**of Poles**|**Quantity**|**Weight Lbs (kg)**|**Dimensions**|
|1|24|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|2|12|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|3|8|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-23**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
**==> picture [183 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH<br>**----- End of picture text -----**<br>
**==> picture [90 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single-Pole Two-Pole<br>QCR (Rear-Mounted Breakers)<br>**----- End of picture text -----**<br>
**==> picture [89 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single-Pole Two-Pole<br>QCF (Front-Mounted Breakers)<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types||
|QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||
|QCRH, QCFH||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-25**|
|QCR and QCF Options and Accessories . . . . . . .|**V4-T1-27**|
|Cable-In/Cable-Out Ground Fault and Equipment||
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||
|Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-40**|
## **Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH**
## **Product Description**
Eaton Type QCR circuit breakers have as a standard feature provisions for 35 mm DIN rail rear mounting with a spring-loaded release. Optional clips for individual mounting are available as a separate accessory.
Type QCF have two threaded steel inserts to facilitate front mounting with #6–32 steel screws. The clamp type terminals are accessible from the rear of the breaker so that cables can be accessed without removal of the breaker from the front cover.
## **Application Description**
QCR and QCF circuit breakers are only 1/2-inch (12.7 mm) wide per pole and are excellent for general purpose industrial applications where space savings is required.
## **Features, Benefits and Functions**
- 1/2-inch (12.7 mm) wide per pole
- Cable-in/cable-out
- Black cases with black handles
- Three position handle: ON, Tripped (center), OFF
- Thermal-magnetic protection
## **Standards and Certifications**
- Built and listed to UL 489
- UL File No. E7819
- CSA File No. LR48907
- Type QCR and QCF circuit breakers are UL listed circuit breakers that are suitable for use as branch circuit protectors
- All ratings 15–60A are HACR rated
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-24**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
## **QCR Breaker Catalog Numbers**[1234]
|**Cable-In/Cable-Out,**|**QCR Breaker Catalog Numbers**|**QCR Breaker Catalog Numbers**|**QCR Breaker Catalog Numbers**[1234]|||
|---|---|---|---|---|---|
|**1/2-Inch Wide**|**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**120/240 Vac**|**Two-Pole**<br>**240 Vac** 5|**Three-Pole**|
||**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
||**QCR Breaker 10 kAIC Interrupting Ratings**|||||
||10|**QCR1010**|**QCR2010**|**—**|**—**|
|||**QCR1010T**|**QCR2010T**|**—**|**—**|
|||**—**|**QCR2010P**|**—**|**—**|
||15|**QCR1015**6|**QCR2015**|**QCR2015H**|**QCR3015H**|
|||**QCR1015T**6|**QCR2015T**|**QCR2015HT**|**QCR3015HT**|
|||**—**|**QCR2015P**|**—**|**—**|
||20|**QCR1020**6|**QCR2020**|**QCR2020H**|**QCR3020H**|
|||**QCR1020T**6|**QCR2020T**|**QCR2020HT**|**QCR3020HT**|
|||**—**|**QCR2020P**|**—**|**—**|
||25|**QCR1025**|**QCR2025**|**QCR2025H**|**QCR3025H**|
|||**QCR1025T**|**QCR2025T**|**QCR2025HT**|**QCR3025HT**|
|||**—**|**QCR2025P**|**—**|**—**|
||30|**QCR1030**|**QCR2030**|**QCR2030H**|**QCR3030H**|
|||**QCR1030T**|**QCR2030T**|**QCR2030HT**|**QCR3030HT**|
|||**—**|**QCR2030P**|**—**|**—**|
||35|**QCR1035**|**QCR2035**|**—**|**—**|
|||**—**|**QCR2035P**|**—**|**—**|
||40|**QCR1040**|**QCR2040**|**—**|**—**|
|||**—**|**QCR2040P**|**—**|**—**|
||45|**QCR1045**|**QCR2045**|**—**|**—**|
|||**—**|**QCR2045P**|**—**|**—**|
||50|**QCR1050**|**QCR2050**|**—**|**—**|
|||**—**|**QCR2050P**|**—**|**—**|
||55|**QCR1055**|**QCR2055**|**—**|**—**|
|||**—**|**QCR2055P**|**—**|**—**|
||607|**QCR1060**|**QCR2060**|**—**|**—**|
|||**—**|**QCR2060P**|**—**|**—**|
||**QCR Breaker 22 kAIC Interrupting Ratings**|||||
||15|**QCRH1015**6|**QCRH2015**|**—**|**—**|
|||**QCRH1015T**6|**QCRH2015T**|**—**|**—**|
||20|**QCRH1020**6|**QCRH2020**|**—**|**—**|
|||**QCRH1020T**6|**QCRH2020T**|**—**|**—**|
## _**Notes**_
- 1 Standard breaker terminals are box type lugs.
- 2 Breakers with **T** Catalog Number Suffix are suitable for line and load side ring terminal connection (#10–32 plus/minus terminal screw provided).
- 3 Breakers with **P** Catalog Number Suffix are suitable for terminating two 10 AWG Quick-Connect Type Terminals per phase on breaker load side.
- 4 Breakers with Shunt Trip (extra pole required on breaker right-hand side) are available on single-, two- and three-pole. Contact the Customer Support Center at 1-800-356-1243.
- 5 Breakers with **H** Catalog Suffix have 240 Vac construction.
- 6 All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications.
- 7 60/75°C Cu/Al wire on all ratings except 60A, which requires Cu only conductor.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-25**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1 Cable-In/Cable-Out, 1/2-Inch Wide**
## **QCF Breaker Catalog Numbers**[123]
||**Continuous**<br>**Ampere Rating**<br>**at 40°C**|**Single-Pole**<br>**120/240 Vac**<br>**Catalog Number**|**Two-Pole**<br>**120/240 Vac**<br>**Catalog Number**|**Two-Pole**<br>**240 Vac** 4<br>**Catalog Number**|**Three-Pole**<br>**Catalog Number**|
|---|---|---|---|---|---|
||**QCF Breaker 10 kAIC Interrupting Ratings**||**QCF Breaker 10 kAIC Interrupting Ratings**|||
||10|**QCF1010**|**QCF2010**|**—**|**—**|
|||**QCF1010T**|**QCF2010T**|**—**|**—**|
||15|**QCF1015**5|**QCF2015**|**QCF2015H**|**QCF3015H**|
|||**QCF1015T**5|**QCF2015T**|**QCF2015HT**|**QCF3015HT**|
||20|**QCF1020**5|**QCF2020**|**QCF2020H**|**QCF3020H**|
|||**QCF1020T**5|**QCF2020T**|**QCF2020HT**|**QCF3020HT**|
||25|**QCF1025**|**QCF2025**|**QCF2025H**|**QCF3025H**|
|||**QCF1025T**|**QCF2025T**|**QCF2025HT**|**QCF3025HT**|
||30|**QCF1030**|**QCF2030**|**QCF2030H**|**QCF3030H**|
||35|**QCF1030T**<br>**QCF1035**|**QCF2030T**<br>**QCF2035**|**QCF2030HT**<br>**—**|**QCF3030HT**<br>**—**|
||40|**QCF1040**|**QCF2040**|**—**|**—**|
||45|**QCF1045**|**QCF2045**|**—**|**—**|
||50|**QCF1050**|**QCF2050**|**—**|**—**|
||55|**QCF1055**|**QCF2055**|**—**|**—**|
|606||**QCF1060**|**QCF2060**|**—**|**—**|
||**QCF Breaker 22 kAIC Interrupting Ratings**<br>15<br>**QCFH1015**5||**QCF Breaker 22 kAIC Interrupting Ratings**<br>**QCFH2015**|**—**|**—**|
|||**QCFH1015T**5|**QCFH2015T**|**—**|**—**|
||20|**QCFH1020**5|**QCFH2020**|**—**|**—**|
|||**QCFH1020T**5|**QCFH2020T**|**—**|**—**|
## _**Notes**_
- 1 Standard breaker terminals are box type lugs.
- 2 Breakers with **T** Catalog Number Suffix are suitable for line and load side ring terminal connection
- (#10–32 plus/minus terminal screw provided).
- 3 Breakers with Shunt Trip Attachment (extra pole required on breaker right-hand side) are available. Contact the Customer Support Center.
- 4 Breakers with **H** Catalog Suffix have 240 Vac construction.
- 5 All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications.
- 6 60/75°C Cu/Al wire on all ratings except 60A, which requires Cu only conductor.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-26**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **QCR and QCF Options and Accessories**
## _**QCR and QCF Standard Box Terminals**_
Factory-installed line and load side breaker terminal to accommodate14 AWG to 4 AWG wire.
## **Standard Box Terminals**
## _**QCR Quick-Connect Terminals**_
Factory-installed two-prong quick-connect terminal on breaker load side suitable for terminating two 10 AWG wire with insulated slip-on terminals as shown. Line side terminal is the standard type. **Catalog Suffix “P”**
## **Available QCR and QCF Breaker Accessories**
_**QCR and QCF Ring or Spade Lug Terminals (10 to 30A Ratings Only)**_
**Catalog** Factory-installed line and load **Description Number** Steel mounting clip **QCRMTGFT** mounts QCR breaker if individual mounting is required. Quantity two spade type terminal as shown. required for single- and twopole and four required for three-pole breakers. Removable padlock **QCRFPL1P** device for single-pole QCR or QCF breaker. ~~—~~ Removable padlock **QCRFPLMP** device for multi-pole QCR or QCF breaker. Padlock bracket assem- **QCRFLOFF** bly for QCR or QCF ~~a~~ single- or multi-pole breakers (OFF only). Padlock bracket for **QCRPLOFF** QCR, lock-off only.
Factory-installed line and load side terminals each equipped with a #10–32 screw suitable for terminating one 10 AWG wire with insulated ring or spade type terminal as shown.
**Catalog Suffix “T”**
## **Technical Data and Specifications**
- Single-, two- and three-pole
- 10 kAIC at 120/240 Vac, 10–60A
- 22 kAIC at 120/240 Vac, 15–20A
- 10 kAIC at 240 Vac, 10–30A
- 3 kAIC at 62.5 Vdc (single-pole)
- 3 kAIC at 130 Vdc (two poles in series)
- Normal operating environment:
- 0–40°C
- 5–95% humidity (noncondensing)
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-27**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1** ~~__~~
**==> picture [102 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
QUICKLAG Type QCGFT Single-Pole<br>Ground Fault Circuit Breaker<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types||
|QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|
|Cable-In/Cable-Out Ground Fault and Equipment||
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-29**|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-30**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-30**|
|Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-40**|
## **Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**
## **Product Description**
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- 5 mA trip sensitivity
## _**QUICKLAG Ground Fault Equipment Protectors**_
- 30 mA trip sensitivity
## **Standards and Certifications**
## _**QUICKLAG Ground Fault Circuit Breakers, Class A GFCI**_
- Built and tested to UL 943
## _**QUICKLAG Ground Fault Equipment Protectors**_
- Built and tested to UL 1053
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-28**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
**QUICKLAG Type QCGFT Single-Pole Ground Fault Circuit Breaker**
## **Breaker Catalog Numbers**
||**Continuous**<br>**Ampere Rating**|**Single-Pole**<br>**120 Vac**|**Two-Pole**<br>**120/240 Vac**|
|---|---|---|---|
||**at 40°C**|**Catalog Number**|**Catalog Number**|
||**Ground Fault Circuit Breakers—5 mA Sensitivity**|||
||**QUICKLAG Type: QCGFT 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|||
||15|**QCGFT1015**|**QCGFT2015**|
||20|**QCGFT1020**|**QCGFT2020**|
||25|**QCGFT1025**|**QCGFT2025**|
||30|**QCGFT1030**|**QCGFT2030**|
||40|**QCGFT1040**|**QCGFT2040**|
||50|**—**|**QCGFT2050**|
||**QUICKLAG Type: QCHGFT 22,000A Interrupting Capacity Thermal-Magnetic Breakers**|||
||15|**QCHGFT1015**|**QCHGFT2015**|
||20|**QCHGFT1020**|**QCHGFT2020**|
||25|**QCHGFT1025**|**QCHGFT2025**|
||30|**QCHGFT1030**|**QCHGFT2030**|
||**Ground Fault Equipment Protectors—30 mA Sensitivity**|||
||**QUICKLAG Type: QCGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers**|||
||15|**QCGFEP1015**|**QCGFEP2015**|
||20|**QCGFEP1020**|**QCGFEP2020**|
||25|**QCGFEP1025**|**QCGFEP2025**|
||30|**QCGFEP1030**|**QCGFEP2030**|
||40|**QCGFEP1040**|**QCGFEP2040**|
||50|**—**|**QCGFEP2050**|
||**QUICKLAG Type: QCHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers**|||
||15|**QCHGFEP1015**|**QCHGFEP2015**|
||20|**QCHGFEP1020**|**QCHGFEP2020**|
||25|**QCHGFEP1025**|**QCHGFEP2025**|
||30|**QCHGFEP1030**|**QCHGFEP2030**|
||**Special Application Ground Fault Circuit Protector—5 mA Sensitivity**|||
||**QUICKLAG Type: QCGFT 10,000A Interrupting Capacity with Bell Alarm (W1) or**|||
||**Auxiliary Switch (W2)**|||
||15|**QCGFT1015W1**|**QCGFT2015W1**|
||20|**QCGFT1020W1**|**QCGFT2020W1**|
||25|**QCGFT1025W1**|**QCGFT2025W1**|
||30|**QCGFT1030W1**|**QCGFT2030W1**|
||40|**—**|**QCGFT2040W1**|
||50|**—**|**QCGFT2050W1**|
||15|**QCGFT1015W2**|—|
||20|**QCGFT1020W2**|—|
||25|**QCGFT1025W2**|—|
||30|**QCGFT1030W2**|—|
||**Special Application Ground Fault Equipment Protectors—30 mA Sensitivity**|||
||**QUICKLAG Type: QCGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or**||**QUICKLAG Type: QCGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or**|
||**Auxiliary Switch (W2)**|||
||15|**QCGFEP1015W1**|**QCGFEP2015W1**|
||20|**QCGFEP1020W1**|**QCGFEP2020W1**|
||25|**QCGFEP1025W1**|**QCGFEP2025W1**|
||30|**QCGFEP1030W1**|**QCGFEP2030W1**|
||40|**—**|**QCGFEP2040W1**|
||50|**—**|**QCGFEP2050W1**|
||15|**QCGFEP1015W2**|**—**|
||20|**QCGFEP1020W2**|**—**|
||25|**QCGFEP1025W2**|**—**|
|30||**QCGFEP1030W2**|**—**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-29**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Wiring Diagram**
## **Bell Alarm and Auxiliary Contact Schematic**
|Ground<br>Fault<br>Breaker|Blue Wire<br>Red Wire<br>Black Wire<br>Blue<br>Red<br>NC<br>NO|
|---|---|
Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)—contacts change state when breaker trips. Auxiliary Switch (W2)—contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided.
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Number**<br>**of Poles**|**Carton**<br>**Quantity**|**Approximate**<br>**Weight Lbs (kg)**|**Dimensions**|
|---|---|---|---|
|1<br>2|20<br>5|11.00 (5.0)<br>5.00 (2.3)|12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)<br>15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3)|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-30**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **BABRP and BABRSP Breakers— Single- and Two-Pole**
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**||**1**|
|**_Description_**|**_Page_**||
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|**1**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**||
|QUICKLAG Plug-On Ground Fault and Equipment||**1**|
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**||
|Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types|**V4-T1-11**|**1**|
|QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Ground Fault and Equipment Protectors,|**V4-T1-14**|**1**|
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP. . . . . .<br>Cable-In/Cable-Out Types QC, QCD, QCHW,|**V4-T1-17**|**1**|
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**||
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||**1**|
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**||
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||**1**|
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP||**1**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-32**||
|Technical Data and Specifications. . . . . . . . . . . .|**V4-T1-33**|**1**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-33**||
|Solenoid Operator—Remote Controlled Latching for||**1**|
|Type GHBS, GBHS and GHQRSP Breakers. . . . . . . .|**V4-T1-34**||
|International Rated Types HQP, BA, QC, GFMB, GFXBC<br>Special Application Breakers, Types HQP, BA, QC. . . .|**V4-T1-37**<br>**V4-T1-40**|**1**|
## **Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP**
## **Product Description**
The BABRP and BABRSP are bolt-on branch circuit breakers designed for use in panelboards. The BRRP is a plug-on branch circuit breaker designed for use in loadcenters not manufactured with breakers with a 1-inch wide format and are listed on the “Compatibility list for Classified Applications”— Pub. 26271. In addition to providing conventional branch circuit protection, they include a unique solenoid-operated mechanism that provides for efficient breaker pulse-on and pulse-off operation when used with a suitable controller like Eaton’s Pow-R-Command™ lighting control system. These breakers can also be controlled by pushbutton or a PLC unit.
## **Application Description**
Eaton’s BABRP, BABRSP, BRRP and CLRP breakers are remotely operated molded case circuit breakers ideally suited for lighting control applications or energy management applications.
## **Features, Benefits and Functions**
- Bolt-on line-side terminal ● Handle permits manual (BABRP, BABRSP— switching when control Type BA) power is lost
- Plug-on line-side terminal ● Mechanical trip indicator (BRRP—Type BR, CLRP— ● 15 and 20A breakers SWD Type CL) (switching duty) rated
- Cable connected load-side ● HID ratings for HID (high terminal intensity discharge) lighting
- Four-position control terminal
- All models HACR rated
- Status feedback of control
- ● Bi-metal assembly for circuit (BABRSP) thermal overload ● Series rated (BABRP, protection
- Series rated (BABRP, BABRSP only)
- Fast-acting short-circuit protection
- BRRP series rated same as BR breakers
- Arc-chute assembly for ● BABRP, BABRSP same fast-acting arc extinction as BA breakers
- Three-position handle: OFF, TRIP (Center), ON
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-31**
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
## 1.1
## **1**
## **Product Selection**
## **QUICKLAG Type QCGFT Single-Pole Ground Fault Circuit Breaker**
## **BABRP UL 489 and CSA 22.2 Interrupting Ratings**
||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|
|---|---|---|---|---|
|**Number**<br>**of Poles**|**Ampere**<br>**Rating**1|**Vac (50/60 Hz)**<br>**120**<br>**120/240 **|**277/480**|**Catalog**<br>**Number**|
|1|15|10,000 —|—|**BABRP1015**|
||20|10,000 —|—|**BABRP1020**|
||25|10,000 —|—|**BABRP1025**|
||30|10,000 —|—|**BABRP1030**|
|2|15|—<br>10,000|—|**BABRP2015**|
||20|—<br>10,000|—|**BABRP2020**|
||25|—<br>10,000|—|**BABRP2025**|
||30|—<br>10,000|—|**BABRP2030**|
## **BABRP and BABRSP Wire Harness**
|**Description**|**Catalog**<br>**Number**|
|---|---|
|This 60-inch (1524.0 mm) wire pigtail provides<br>a connection from a single BABRP’s control plug to|**SLBKRPTL1**|
|a customer’s pushbutton, relay or PLC. Each box||
|contains 12 pigtails. Wires are 22 AWG, 600V.<br>Order in multiples of 12.||
## **BABRSP UL 489 and CSA 22.2 Interrupting Ratings**
|**Number**|**Interrupting Capacity (Symmetrical Amperes)**<br>**Ampere**<br>**Vac (50/60 Hz)**|**Interrupting Capacity (Symmetrical Amperes)**<br>**Ampere**<br>**Vac (50/60 Hz)**|**Interrupting Capacity (Symmetrical Amperes)**<br>**Ampere**<br>**Vac (50/60 Hz)**|**Interrupting Capacity (Symmetrical Amperes)**<br>**Ampere**<br>**Vac (50/60 Hz)**|**Interrupting Capacity (Symmetrical Amperes)**<br>**Catalog**|
|---|---|---|---|---|---|
|**of Poles**|**Rating**1|**120**|**120/240 **|**277/480**|**Number**|
|1|15|10,000|—|—|**BABRSP1015**|
||20|10,000|—|—|**BABRSP1020**|
||25|10,000|—|—|**BABRSP1025**|
||30|10,000|—|—|**BABRSP1030**|
|2|15<br>20|—<br>—|10,000<br>10,000|—<br>—|**BABRSP2015**<br>**BABRSP2020**|
||25|—|10,000|—|**BABRSP2025**|
||30|—|10,000|—|**BABRSP2030**|
## **BRRP UL 489 and CSA 22.2 Interrupting Ratings**
||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|
|---|---|---|---|---|
|**Number**|**Ampere**|**Vac (50/60 Hz)**|**Vac (50/60 Hz)**|**Catalog**|
|**of Poles**|**Rating**|**120**|**120/240**|**Number**|
|1|15|10,000|—|**BRRP115**|
||20|10,000|—|**BRRP120**|
||25|10,000|—|**BRRP125**|
||30|10,000|—|**BRRP130**|
|2|15|—|10,000|**BRRP215**|
||20|—|10,000|**BRRP220**|
||25|—|10,000|**BRRP225**|
||30|—|10,000|**BRRP230**|
## **CLRP UL 489 and CSA 22.2 Interrupting Ratings**
||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|
|---|---|---|---|---|
|**Number**|**Ampere**|**Vac (50/60 Hz)**|**Vac (50/60 Hz)**|**Catalog**|
|**of Poles**|**Rating**|**120**|**120/240**|**Number**|
|1|15|10,000|—|**CLRP115**|
||20|10,000|—|**CLRP120**|
||25|10,000|—|**CLRP125**|
||30|10,000|—|**CLRP130**|
|2|15|—|10,000|**CLRP215**|
||20|—|10,000|**CLRP220**|
||25|—|10,000|**CLRP225**|
||30|—|10,000|**CLRP230**|
## _**Note**_
> 1 Continuous current rating at 40°C.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-32**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Technical Data and Specifications**
## _**Solenoid Operating Data**_
## _**Operation**_
- Power requirements: 24 Vac/dc (20.4V minimum– 30V maximum)
- Tripping system—the BABRP, BABRSP, BRRP and CLRP circuit breakers have a permanent trip unit that contains a factory preset thermal (overload) trip element in each pole
- Controlled signal: +AC/DC 8 ms minimum with zero cross, 300 ms maximum
- Operating mechanism— the BABRP, BABRSP, BRRP and CLRP circuit breakers have an over-center toggle mechanism that provides quick-make, quick-break operation. The operating mechanism is trip free. An internal cross-bar provides a common tripping of all multi-pole circuit breakers
- AC: 1.3 cycles minimum, 18 cycles or 300 ms maximum
- DC: 8 ms minimum, 300 ms maximum
- Maximum duty cycle of 6 OPEN/CLOSE cycles per minute
- Current draw: open 1A, close 3/4A
- Blue wire: power input (see power requirements)
## _**Operating/Application Data**_
- Ambient temperature: 0 to 40°C
- Black wire: remote opening
- Red wire: remote closing
- Nominal pulse magnitude: 24 Vac/dc
- Yellow wire: feedback status from power input, maximum 0.50A draw (BABRSP only)
- Frequency: 50/60 Hz
- Maximum breaker cycling: 6 operations per minute
## **Wiring Diagrams**
## **Control Circuit for the BABRP and BABRSP**
**==> picture [205 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
BABRP BABRSP<br>Remote Remote<br>Contact Contact<br>Load Line Load Line<br>Breaker Breaker<br>Contact Contact<br>RM RM<br>RM RM BKR<br>b a b a a<br>On Off Remote On Off Remote<br>Coil Coil Status Coil Coil Status<br>Red Black Yellow Blue Red Black Yellow Blue<br>**----- End of picture text -----**<br>
- Tolerance: +10% to –15% of nominal voltage
- Humidity: 0 to 95% noncondensing
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-33**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **GHBS and GHQRSP**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types||
|QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|
|Cable-In/Cable-Out Ground Fault and Equipment||
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||
|Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-35**|
|Technical Data and Specifications . . . . . . . . . . . .|**V4-T1-36**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-36**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC . . .|**V4-T1-40**|
## **Solenoid Operator—Remote-Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers**
## **Product Description**
Eaton’s GHBS, GBHS and GHQRSP circuit breakers are bolt-on branch circuit breakers designed for use in 277/480 Vac panelboards. In addition to providing conventional branch circuit protection, they include a unique solenoid-operated mechanism that provides for efficient breaker pulse-on and pulse-off operation when used with a suitable controller like Eaton’s Pow-R-Command lighting control system.
## **Features, Benefits and Functions**
- Bolt-on line-side terminal
- Cable-connected load-side terminal
- Status switch—remote status and breaker status available from internal auxiliary switches
- Bi-metal assembly for thermal overload protection
- Fast-acting short-circuit protection
- Arc-runner and arc-chute assembly for fast-acting arc extinction
- Visual indication of the remotely operated contact’s position (open, closed or trip)
- Remote override handle permits manual switching when control power is lost
- 15 and 20A breakers SWD (switching duty) rated.
- 15 and 20A breakers HID rated for HID (High intensity discharge) lighting
- All models HACR rated
- Series rated with various Eaton main circuit breakers
- Three-position breaker handle: OFF, TRIP (Center), ON
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-34**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
## **GHBS UL 489 Interrupting Ratings**
|**GHBS—Single-Pole**|**GHBS UL 489 Interrupting Ratings**|**GHBS UL 489 Interrupting Ratings**|**GHBS UL 489 Interrupting Ratings**||||
|---|---|---|---|---|---|---|
|||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**||||
||**Number**|**Ampere**|**Vac (50/60 Hz)**||||
||**of Poles**|**Rating** 1|**120**|**240**|**277/480**|**Catalog Number**|
||1|15|65,000|—|14,000|**GHBS1015D**|
|||20|65,000|—|14,000|**GHBS1020D**|
|||30|65,000|—|14,000|**GHBS1030D**|
||2|15|—|65,000|14,000|**GHBS2015D**|
|||20|—|65,000|14,000|**GHBS2020D**|
|||30|—|65,000|14,000|**GHBS2030D**|
## **GBHS CSA 22.2 Interrupting Ratings (Not UL Listed)**
||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**||
|---|---|---|---|
|**Number**|**Ampere**|**Vac (50/60 Hz)**||
|**of Poles**|**Rating**1|**347/600**|**Catalog Number**|
|1|15|10,000|**GBHS1015D**|
||20|10,000|**GBHS1020D**|
|2|15|10,000|**GBHS2015D**|
||20|10,000|**GBHS2020D**|
## **GHQRSP UL 489 and CSA 22.2 Interrupting Ratings**
||**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|**Interrupting Capacity (Symmetrical Amperes)**|||
|---|---|---|---|---|---|---|
|**Number**|**Ampere**|**Vac (50/60 Hz)**|||||
|**of Poles**|**Rating**1|**120**|**120/240**|**277**|**480Y/277**|**Catalog Number**2|
|1|15|65,000|65,000|14,000|14,000|**GHQRSP1015**|
||20|65,000|65,000|14,000|14,000|**GHQRSP1020**|
||30|65,000|65,000|14,000|14,000|**GHQRSP1030**|
|2|15|65,000|65,000|14,000|14,000|**GHQRSP2015**|
||20|65,000|65,000|14,000|14,000|**GHQRSP2020**|
||30|65,000|65,000|14,000|14,000|**GHQRSP2030**|
## _**Notes**_
1 Continuous current rating at 40°C.
2 All UL listed circuit breakers are HID (high intensity discharge) rated.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-35**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Technical Data and Specifications**
## _**Solenoid Operating Data**_
- Red wire: remote closing
- Yellow wire: feedback status from power input, maximum 0.50A draw
- Power requirements: 24 Vac/dc (20.4V minimum– 30V maximum)
- Controlled signal: +AC/ DC 8 ms minimum with zero cross, 300 ms maximum
## _**Operation**_
- Mechanism manually operated by external handle allowing ON, OFF and RESET operation. Handle assumes a center TRIP position after performing protective response.
- AC: 1.3 cycles minimum, 18 cycles or 300 ms maximum
- DC: 8 ms minimum, 300 ms maximum
- Maximum duty cycle of 6 OPEN/CLOSE cycles per minute
## _**Operating/Application Data**_
- Ambient temperature: 0–40°C
- Current draw: open 1A, close 3/4A
- Frequency: 48–62 Hz
- Humidity: 0–95% noncondensing
- Blue wire: power input (see power requirements)
- Black wire: remote opening
## **Terminal Type**
|**Circuit Breaker**<br>**Type**|**Circuit Breaker**<br>**Amperes**|**Screw**<br>**Head Type**|**Terminal**<br>**Type**|**Range**|
|---|---|---|---|---|
|GHQRSP|15–20|Slotted|Clamp|#14–#4 AWG|
## **Wiring Diagrams**
**Typical Single-Pole Circuit Breaker Schematic Diagram for GHBS and GBHS Breakers**
**==> picture [167 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit Breaker<br>Solenoid<br>a<br>Common Solenoid Auxiliary<br>AMP Inc. 1/2 Cycle<br>Conductor<br>Maximum<br>Plug 1 28 Vac<br>Pulse Source<br>28 Vac<br>Circuit Breaker<br>Open/Closed<br>Status<br>**----- End of picture text -----**<br>
**Typical Single-Pole Circuit Breaker Schematic Diagram for GHQRSP Breakers**
**==> picture [132 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
GHQRSP<br>Remote Breaker<br>Contact Contact<br>Load Line<br>Status On Off Power<br>Coil Coil Input<br>Yellow Red Black Blue<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Dimensions per Pole**
|**Dimensions per Pole**||||
|---|---|---|---|
|**Circuit Breaker Type**|**Width**|**Height**2|**Length**3|
|GHQRSP|1.00 (25.4)|4.63 (117.6)|2.81 (71.4)|
|**_Notes_**||||
- 1 Purchase separate AMP Inc. conductor plug #640426-3.
- 2 Excluding line terminal.
- 3 Excluding handle.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-36**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**==> picture [55 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
International Rated<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**|||
|---|---|---|
|**Contents**||**1**|
|**_Description_**|**_Page_**||
|Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|**1**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**||
|QUICKLAG Plug-On Ground Fault and Equipment||**1**|
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**||
|Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . .<br>Bolt-On Arc Fault Circuit Interrupter Types|**V4-T1-11**|**1**|
|QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Bolt-On Ground Fault and Equipment Protectors,|**V4-T1-14**|**1**|
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP. . . . . .<br>Cable-In/Cable-Out Types QC, QCD, QCHW,|**V4-T1-17**|**1**|
|QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**||
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||**1**|
|QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**||
|Cable-In/Cable-Out Ground Fault and Equipment<br>Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP**V4-T1-28**||**1**|
|Solenoid-Operated, Remote-Controlled Latching<br>Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . .|**V4-T1-31**|**1**|
|Solenoid Operator—Remote Controlled Latching for<br>Type GHBS, GBHS and GHQRSP Breakers. . . . . . . .|**V4-T1-34**|**1**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-38**|**1**|
|Technical Data and Specifications. . . . . . . . . . . .|**V4-T1-39**||
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Special Application Breakers, Types HQP, BA, QC. . . .|**V4-T1-39**<br>**V4-T1-40**|**1**|
## **International Rated Types HQP, BA, QC, GFMB, GFXBC Product Description Standards and Certifications**
## _**QUICKLAG International Circuit QUICKLAG International Circuit Breakers Breakers**_
- Bolt-on Type BA
## _**QUICKLAG International Ground Fault Circuit Breakers**_
- Plug-on Type GFMB
- Cable-in/cable-out Type GFXBC
- Built and test certified to BS3871, Pt. 1
- 50/60 Hz, 40°C
## _**QUICKLAG International Ground Fault Circuit Breakers**_
- Built and test certified to BS3871, Pt. 1; BS3871, Section 31-C; BS4293
- 50/60 Hz, 40°C; 30 mA sensitivity
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-37**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **Product Selection 1** ~~ee~~
## **BAB**
## **Breaker Catalog Numbers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|
|**Ampere Rating**<br>**at 40°C**|**240/415 Vac**<br>**Catalog Number**|**240/415 Vac**<br>**Catalog Number**|**240/415 Vac**<br>**Catalog Number**|
|**3000A Interrupting Capacity (M3) Bolt-On Thermal-Magnetic Circuit Breakers**|**3000A Interrupting Capacity (M3) Bolt-On Thermal-Magnetic Circuit Breakers**|**3000A Interrupting Capacity (M3) Bolt-On Thermal-Magnetic Circuit Breakers**||
|10|**BAB1010E**|**BAB2010E**|**BAB3010E**|
|15|**BAB1015E**|**BAB2015E**|**BAB3015E**|
|16<br>20|**—**<br>**BAB1020E**|**—**<br>**BAB2020E**|**—**<br>**BAB3020E**|
|25|**BAB1025E**|**BAB2025E**|**BAB3025E**|
|30|**BAB1030E**|**BAB2030E**|**BAB3030E**|
|32|**—**|**—**|**—**|
|40|**BAB1040E**|**BAB2040E**|**BAB3040E**|
|50|**BAB1050E**|**BAB2050E**|**BAB3050E**|
|60<br>70|**BAB1060E**<br>**BAB1070E**|**BAB2060E**<br>**BAB2070E**|**BAB3060E**<br>**BAB3070E**|
|90|**—**|**BAB2090E**|**BAB3090E**|
|100|**—**|**BAB2100E**|**BAB3100E**|
|**6000A Interrupting Capacity (M6) Bolt-On Thermal-Magnetic Circuit Breakers**|**6000A Interrupting Capacity (M6) Bolt-On Thermal-Magnetic Circuit Breakers**|**6000A Interrupting Capacity (M6) Bolt-On Thermal-Magnetic Circuit Breakers**||
|15|**BAB1015HE**|**BAB2015HE**|**BAB3015HE**|
|20|**BAB1020HE**|**BAB2020HE**|**BAB3020HE**|
|25|**BAB1025HE**|**BAB2025HE**|**BAB3025HE**|
|30|**BAB1030HE**|**BAB2030HE**|**BAB3030HE**|
|40|**BAB1040HE**|**BAB2040HE**|**BAB3040HE**|
|50|**BAB1050HE**|**BAB2050HE**|**BAB3050HE**|
|60|**BAB1060HE**|**BAB2060HE**|**BAB3060HE**|
|70<br>90|**BAB1070HE**<br>**—**|**BAB2070HE**<br>**BAB2090HE**|**BAB3070HE**<br>**BAB3090HE**|
|100|**—**|**BAB2100HE**|**BAB3100HE**|
## **Breaker Catalog Numbers—Ground Fault Single-Pole 30 mA Sensitivity**
|**Continuous**<br>**Ampere Rating**|**240/415 Vac**|
|---|---|
|**at 40°C**<br>**Catalog Number**<br>**3000A Interrupting Capacity (M3) Plug-On Thermal-Magnetic Circuit Breakers**||
|10|**GFMB110B2**|
|15|**GFMB115B2**|
|16|**GFMB116B2**|
|20|**GFMB120B2**|
|25|**GFMB125B2**|
|30|**GFMB130B2**|
|32|**GFMB132B2**|
|40|**GFMB140B2**|
## _**Note**_
For other 240/415V applications, please contact the Customer Support Center at 1-800-356-1243.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-38**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Technical Data and Specifications**
## **Interrupting Ratings**
|**Ratings**|**Suffix E**|**Suffix HE**|
|---|---|---|
|**International Circuit**|**Breakers**||
|NEMA®|10,000 AIC|10,000 AIC|
|120/240 Vac|||
|BS3871 220/380,|3000 AIC|6000 AIC|
|240/415 Vac|||
|**International Ground Fault Circuit Breakers**|||
|BS3871 220/380,|3000 AIC||
|240/415 Vac|||
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Shipping Data**||
|---|---|
|**Miniature**<br>**Circuit Breaker**|**Number**<br>**of Poles**<br>**Standard Carton**<br>**Quantity**<br>**Approximate Carton**<br>**Weight Lbs (kg)**<br>**Approximate**<br>**Standard Carton**|
|QUICKLAG Type B|1<br>24<br>9.00 (4.1)<br>12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
||2<br>12<br>9.00 (4.1)<br>12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
||3<br>8<br>9.00 (4.1)<br>12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|**QUICKLAG Ground**|**Fault**|
|Type P—All|1<br>20<br>11.00 (5.0)<br>12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)|
|Types B and C—All|1<br>20<br>11.00 (5.0)<br>12.50 x 7.00 x 5.50 (317.5 x 177.8 x 139.7)|
|Types P and B—All|2<br>5<br>5.00 (2.3)<br>12.50 x 6.00 x 4.50 (317.5 x 152.4 x 114.3)|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-39**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1 QUICKLAG Type P Switching Neutral**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-2**|
|QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW|**V4-T1-5**|
|QUICKLAG Plug-On Ground Fault and Equipment||
|Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP|**V4-T1-8**|
|Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . .|**V4-T1-11**|
|Bolt-On Arc Fault Circuit Interrupter Types||
|QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-14**|
|Bolt-On Ground Fault and Equipment Protectors,||
|Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .|**V4-T1-17**|
|Cable-In/Cable-Out Types QC, QCD, QCHW,||
|QHCX, QHCW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-20**|
|Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,||
|QCRH, QCFH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-24**|
|Cable-In/Cable-Out Ground Fault and Equipment||
|Protectors, Types QCGFT, QCHGFT, QCGFEP, QCHGFEP|**V4-T1-28**|
|Solenoid-Operated, Remote-Controlled Latching||
|Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . .|**V4-T1-31**|
|Solenoid Operator—Remote Controlled Latching for||
|Type GHBS, GBHS and GHQRSP Breakers . . . . . . .|**V4-T1-34**|
|International Rated Types HQP, BA, QC, GFMB, GFXBC|**V4-T1-37**|
|Special Application Breakers, Types HQP, BA, QC||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-41**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-43**|
|Factory Modifications and Installed Terminals . .|**V4-T1-46**|
|Technical Data and Specifications . . . . . . . . . . . .|**V4-T1-47**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V4-T1-48**|
## **Special Application Breakers, Types HQP, BA, QC**
## **Product Description**
## _**Breakers**_
- Plug-on Type HQP: 10–30A, single- and two-pole, 10 kAIC
- Bolt-on Type BA: 10–30A, single- and two-pole, 10 kAIC
- Cable-in Type QC: 10–30A, single- and two-pole, 10 kAIC
Switching neutral QUICKLAG breakers available in singleand two-pole configurations, plus neutral pole for applications in accordance with NEC[®] 514.5, 240.22 and 380.2. A single-pole device takes two pole spaces, and a two-pole device takes three pole spaces.
## _**QUICKLAG HID (High Intensity Discharge) Breakers**_
- Plug-on Type HQP: 15–60A, single- and two-pole, 10 kAIC
- Bolt-on Type BA: 15–60A, single- and two-pole, 10 kAIC
- Cable-in Type QC: 15–60A, single- and two-pole, 10 kAIC
Breakers designed specifically for use with high intensity discharge (HID) lighting applications. (UL listed as standard lighting breakers.)
## _**Molded Case Switches—Nonautomatic QUICKLAG Molded Case Switch**_
- Plug-on Type HQP: 50, 60,100A, single-, two- and three-pole
- Bolt-on Type BA: 50, 60,100A, single-, two- and three-pole
- Cable-in Type QC: 50, 60,100A, single-, two- and three-pole
## **Standards and Certifications**
- All products UL and CSA listed
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-40**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Product Selection**
**QUICKLAG Type P Switching Neutral**
## **Breaker Catalog Numbers**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|**QUICKLAG Type: HQP Switching Neutral Thermal-Magnetic Breakers**|**QUICKLAG Type: HQP Switching Neutral Thermal-Magnetic Breakers**|**QUICKLAG Type: HQP Switching Neutral Thermal-Magnetic Breakers**|||
|10|**HQP2010B**|**HQP3010B**|**—**|**—**|
|15|**HQP2015B**|**HQP3015B**|**—**|**—**|
|20|**HQP2020B**|**HQP3020B**|**—**|**—**|
|25|**HQP2025B**|**HQP3025B**|**—**|**—**|
|30|**HQP2030B**|**HQP3030B**|**—**|**—**|
|**QUICKLAG Type: BA Switching Neutral Thermal-Magnetic Breakers**|**QUICKLAG Type: BA Switching Neutral Thermal-Magnetic Breakers**||||
|10|**BAB2010C**|**BAB3010C**|**—**|**—**|
|15|**BAB2015C**|**BAB3015C**|**—**|**—**|
|20|**BAB2020C**|**BAB3020C**|**—**|**—**|
|25|**BAB2025C**|**BAB3025C**|**—**|**—**|
|30|**BAB2030C**|**BAB3030C**|**—**|**—**|
|**QUICKLAG Type: QC Switching Neutral Thermal-Magnetic Breakers**|**QUICKLAG Type: QC Switching Neutral Thermal-Magnetic Breakers**||||
|10|**QC2010B**|**QC3010B**|**—**|**—**|
|15|**QC2015B**|**QC3015B**|**—**|**—**|
|20|**QC2020B**|**QC3020B**|**—**|**—**|
|25|**QC2025B**|**QC3025B**|**—**|**—**|
|30|**QC2030B**|**QC3030B**|**—**|**—**|
|**QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers**|**QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers**||**QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers**|**QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers**|
|15|**HQP1015D**|**HQP2015D**|**—**|**—**|
|20|**HQP1020D**|**HQP2020D**|**—**|**—**|
|25|**HQP1025D**|**HQP2025D**|**—**|**—**|
|30|**HQP1030D**|**HQP2030D**|**—**|**—**|
|35|**HQP1035D**|**HQP2035D**|**—**|**—**|
|40|**HQP1040D**|**HQP2040D**|**—**|**—**|
|50|**HQP1050D**|**HQP2050D**|**—**|**—**|
|60|**HQP1060D**|**HQP2060D**|**—**|**—**|
|**QUICKLAG Type: BA HID (High Intensity Discharge) Thermal-Magnetic Breakers**|**QUICKLAG Type: BA HID (High Intensity Discharge) Thermal-Magnetic Breakers**||||
|15|**BAB1015D**|**BAB2015D**|**—**|**—**|
|20|**BAB1020D**|**BAB2020D**|**—**|**—**|
|25|**BAB1025D**|**BAB2025D**|**—**|**—**|
|30|**BAB1030D**|**BAB2030D**|**—**|**—**|
|35|**BAB1035D**|**BAB2035D**|**—**|**—**|
|40|**BAB1040D**|**BAB2040D**|**—**|**—**|
|50|**BAB1050D**|**BAB2050D**|**—**|**—**|
|60|**BAB1060D**|**BAB2060D**|**—**|**—**|
|**QUICKLAG Type: QC HID (High Intensity Discharge) Thermal-Magnetic Breakers**|**QUICKLAG Type: QC HID (High Intensity Discharge) Thermal-Magnetic Breakers**||||
|15|**QC1015D**|**QC2015D**|**—**|**—**|
|20|**QC1020D**|**QC2020D**|**—**|**—**|
|25|**QC1025D**|**QC2025D**|**—**|**—**|
|30|**QC1030D**|**QC2030D**|**—**|**—**|
|35|**QC1035D**|**QC2035D**|**—**|**—**|
|40|**QC1040D**|**QC2040D**|**—**|**—**|
|50|**QC1050D**|**QC2050D**|**—**|**—**|
|60|**QC1060D**|**QC2060D**|**—**|**—**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-41**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **1**
## **Breaker Catalog Numbers, continued**
|**Continuous**|**Single-Pole**|**Two-Pole**|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
|**Ampere Rating**|**120/240 Vac**|**120/240 Vac**|**240 Vac**|**240 Vac**|
|**at 40°C**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|**QUICKLAG Type:**|**HQP Non-Automatic Switches**||||
|50|**HQP1050N**|**—**|**HQP2050N**|**HQP3050N**|
|60|**HQP1060N**|**—**|**HQP2060N**|**HQP3060N**|
|100|**HQP1100N**|**—**|**HQP2100N**|**HQP3100N**|
|**QUICKLAG Type:**|**BA Non-Automatic Switches**||||
|50|**BAB1050N**|**—**|**BAB2050N**|**BAB3050N**|
|60|**BAB1060N**|**—**|**BAB2060N**|**BAB3060N**|
|100|**BAB1100N**|**—**|**BAB2100N**|**BAB3100N**|
|**QUICKLAG Type:**|**QC Non-Automatic Switches**||||
|50|**QC1050N**|**—**|**QC2050N**|**QC3050N**|
|60|**QC1060N**|**—**|**QC2060N**|**QC3060N**|
|100|**QC1100N**|**—**|**QC2100N**|**QC3100N**|
|**QUICKLAG Type:**|**QCD Non-Automatic Switches**||||
|60|**—**|**—**|**QCD2060NA**|**—**|
|100|**—**|**—**|**—**|**—**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-42**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **Accessories**[1]
**1**
||||**Handle Locks: Non-Padlockable**2|||
|---|---|---|---|---|---|
||||**Description**|**Order in Multiples of**|**Catalog Number**|
|**QL1NPL**|||QUICKLAG Type P, B, C—single-pole|10|**QL1NPL**|
||a|||||
|**QL23NPL**|||QUICKLAG Type P, B, C—two- and three-pole|10|**QL23NPL**|
||Do<br>a|||||
||||**Handle Locks: Padlockable**2|||
||||**Description**|**Order in Multiples of**|**Catalog Number**|
|**QL1PL**|||QUICKLAG Type P, B, C—single-pole|10|**QL1PL**|
||M<br>l<br>,|||||
|**QL123PL**|||QUICKLAG Type P, B and ground fault—single-, two- and three-pole|10|**QL123PL**|
|**QC123PL**|||QUICKLAG Type C —single-, two- and three-pole|10|**QC123PL**|
||ait|iv.||||
||||QUICKLAG Type P, B—single-, two- and three-pole (off only)|10|**QL123PLOFF**|
||||QUICKLAG Type C—single-, two- and three-pole (off only)|10|**QC123PLOFF**|
||||**_Notes_**|||
||||1See**Page** **V4-T1-27**for QCR and QCF accessories.|||
||||2Can lock in ON or OFF position.|||
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-43**
Miniature Circuit Breakers and Supplementary Protectors
1.1
## Industrial Circuit Breakers
|**1**|||**Mounting Hardware**<br>**Description**|**Order in Multiples of**|**Catalog Number**|
|---|---|---|---|---|---|
|**1**|**QCFCLIP**||QUICKLAG Type C face mounting clip|24|**QCFCLIP**|
|**1**<br>**1**<br>**1**||.<br>'||||
|**1**|**QC1FP**||QUICKLAG Type C face mounting plate—single-pole|10|**QC1FP**|
|**1**<br>**1**<br>**1**||t<br>‘||||
|**1**||||||
||**QC2FP**||QUICKLAG Type C face mounting plate—two-pole|10|**QC2FP**|
|**1**||—||||
|**1**<br>**1**<br>**1**||t.€<br>a<br>.||||
|**1**|**QC3FP**||QUICKLAG Type C face mounting plate—three-pole|10|**QC3FP**|
|**1**<br>**1**<br>**1**<br>**1**||*<br>c*<br>0<br>¢}<br>cr,|QUICKLAG Type C face mounting plate and lock-off (off only)—two-pole1|10|**QC2FPLOFF**|
|**1**|||QUICKLAG Type C face mounting plate and lock-off (off only)—three-pole|10|**QC3FPLOFF**|
||**QCBCLIP**||QUICKLAG Type C base mounting clamp|10|**QCBCLIP**|
|**1**||||||
|**1**||||||
|**1**||||||
|**1**||>o||||
|**1**|**QC6BP**||QUICKLAG Type mounting plate—six poles total|10|**QC6BP**|
**==> picture [14 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note<br>**----- End of picture text -----**<br>
1 Suitable for ground fault breakers.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-44**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **Mounting Hardware, continued**
|||**Mounting Hardware, continued**|||
|---|---|---|---|---|
|||**Description**|**Order in Multiples of**|**Catalog Number**|
|||QUICKLAG Type C base mounting plate—six poles total—heavy-duty screw-secured|10|**QC6BPS**|
|||QUICKLAG Type C (QCD) 2-way jumper unit with cover|10|**QCDJ2**|
|**QCDJ4**||QUICKLAG Type C (QCD) 4-way jumper unit with cover|10|**QCDJ4**|
|QUICKLAG Type C (QCD) 6-way jumper unit with cover<br>10<br>**QCDJ6**<br>QUICKLAG Type C (QCD) 2-way jumper unit, no cover<br>10<br>**QCDJ2T**<br>QUICKLAG Type C (QCD) 4-way jumper unit, no cover<br>10<br>**QCDJ4T**<br>QUICKLAG Type C (QCD) 6-way jumper unit, no cover<br>10<br>**QCDJ6T**<br>QUICKLAG Type QCD Finger protection attachment<br>10<br>**QCDFP**<br>QUICKLAG Type QCD 4-prong Quick Connect<br>10<br>**QCDQUICK**<br>QUICKLAG Type C DIN rail adapter<br>6<br>**QCDINADAPT**<br>**QCDINADAPT**<br>me~~w~~|||||
**1**
**QCDRING** QUICKLAG Type QCD ring lug attachment 10 **QCDRING**
|**QCDRING**<br>~~¥~~|QUICKLAG Type QCD ring lug attachment<br>~~¥~~|10<br>~~¥~~|**QCDRING**<br>~~¥~~|
|---|---|---|---|
||**Dummy Breakers**|||
||**Description**|**Order in Multiples of**|**Catalog Number**|
||QUICKLAG Type P|1|**HQP1000**|
||QUICKLAG Type B|1|**BAB1000**|
||QUICKLAG Type C|1|**QC1000**|
||QUICKLAG Type C clear choice breaker|4|**QC30SAMPLE**|
|**Miscellaneous**<br>**Description**<br>**Order in Multiples of**<br>**Catalog Number**<br>QUICKLAG Type C Spacer<br>1<br>**QCRSPACER**<br>**QCRSPACER**<br>~~_~~||||
|**QL1HT**|**Handle Tie**|||
||**Description**|**Order in Multiples of**|**Catalog Number**|
|QUICKLAG handle tie—single-pole<br>100<br>**QL1HT**<br>~~—~~||||
**Volume 4—Circuit Protection** CA08100005E—November 2016
www.eaton.com **V4-T1-45**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Factory Modifications and Installed Terminals**
## **Factory Modifications**[1]
|**Factory Modifications**1|||
|---|---|---|
|**Type of Modification**|**Breaker Type**|**Catalog Suffix**|
|Shunt trip (requires one extra pole space on right side)|||
|120, 208, 240 Vac|||
|Draws 2.6A at 120V, draws 11A at 24 Vdc<br>Shunt trip (requires one extra pole space on right side)|QUICKLAG Types P, B and C|**S**|
|24, 48 Vac/dc<br>Draws 2.6A at 120V, draws 11A at 24 Vdc|QUICKLAG Types P, B and C|**S1**|
|Special calibration (50°C) (no UL)|QUICKLAG Types P, B and C|**V**|
|Shock testing|QUICKLAG Types P, B and C|**L**|
|Freeze testing<br>Moisture-fungus treatment|QUICKLAG Types P, B and C<br>QUICKLAG Types P, B, C and ground fault|**Y**<br>**F**|
|Marine duty|QUICKLAG Types P, B, C|**H08**|
|Naval duty|QUICKLAG Types P, B, C|**H09**|
|400 Hz calibration|QUICKLAG Types P, B, C|**G**|
|Specific DC ratings (breaker marked with a max. Vdc rating)|QUICKLAG Types P, B, C|**Q thru Q9**2|
## **Spare Terminal Hardware Screws (Lugs not Included)**
|**Terminal Type**<br>1|**Description**<br>QUICKLAG terminal screw|**Order in Multiples of**<br>10|**Catalog Number**<br>**QLLDTSA**|
|---|---|---|---|
|2|QUICKLAG terminal screw|10|**QLLDTSB**|
|3|QUICKLAG terminal screw|10|**QLLDTSC**|
|5|QUICKLAG binding head terminal screw and clamp|10|**QLBHTSE**|
|6 and 7|QUICKLAG terminal screw|10|**QLLNTSFG**|
## _**Notes**_
> 1 Contact Eaton for factory modifications available for QCR and QCF breakers.
> 2 Q = 32 Vdc; Q1 = 32–40 Vdc; Q2 = 37.5 Vdc; Q3 = 45 Vdc; Q4 = 48 Vdc; Q5 = 50 Vdc; Q6 = 62.5 Vdc; Q7 = 75 Vdc (2P); Q8 = 80 Vdc (2P); Q9 = 125 Vdc (QCR 2P); Q10 = 62.5 Vdc (QCR 1P).
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-46**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
## **Technical Data and Specifications**
**1**
## **Factory-Installed Breaker Terminals**
|**Breaker**<br>**Type**<br>**Co**<br>**Am**<br>**Ra**|**Breaker**<br>**Type**<br>**Co**<br>**Am**<br>**Ra**|**Breaker**<br>**Type**<br>**Co**<br>**Am**<br>**Ra**|**ntinuous**<br>**pere**<br>**ting**||**Standard Line Terminal**<br>**Terminal**<br>**Type**<br>**Wire**<br>**Type**<br>**Wire**<br>**Range (AWG)**|**Standard Line Terminal**<br>**Terminal**<br>**Type**<br>**Wire**<br>**Type**<br>**Wire**<br>**Range (AWG)**|**Standard Line Terminal**<br>**Terminal**<br>**Type**<br>**Wire**<br>**Type**<br>**Wire**<br>**Range (AWG)**|**Standard Load Terminal**<br>**Optional Terminals**<br>**Terminal**<br>**Type**<br>**Wire**<br>**Type**<br>**Wire**<br>**Range (AWG)**<br>**Line**<br>**Load**|
|---|---|---|---|---|---|---|---|---|
|QUICKLAG Type P<br>HQP, QPHW,<br>QHPX, QHPW<br>10<br>35<br>55|||–30||Plug-on female clips that mate<br>with the bus stabs|||1<br>Cu/Al<br>14–4<br>N/A<br>3<br>2<br>Cu/Al<br>14–4<br>N/A<br>3<br>3<br>Cu/Al<br>8–1/0<br>N/A<br>—|
||||–50||||||
||||–125||||||
|QUICKLAG ground fault<br>QPGFT, QPGFEP,<br>QPHGFT, QPHGFEP<br>10<br>10<br>10|||–40||Plug-on female clips that mate<br>with the bus stabs|||1 (single-pole)<br>Cu/Al<br>14–4<br>N/A<br>3<br>1<br>Cu/Al<br>—<br>N/A<br>3<br>1<br>Cu<br>14–8<br>N/A<br>—|
||||–40||||||
||||–30||||||
|QUICKLAG Type B<br>BAB, QBHW,<br>HBAX, HBAW<br>10<br>35<br>55|||–40||Extended tangs that bolt<br>directly to the bus|||1 (single- and two-pole)<br>Cu/Al<br>14–4<br>N/A<br>3<br>2 (three-pole)<br>Cu/Al<br>14–4<br>N/A<br>3<br>3<br>Cu/Al<br>8–1/0<br>N/A<br>—|
||||–50||||||
||||–125||||||
|QUICKLAG ground fault<br>QBGFT, QBGFEP,<br>QBHGFEP, QBHGFT<br>10<br>10<br>10|||–40||Extended tangs that bolt<br>directly to the bus|||1 (single-pole)<br>Cu/Al<br>14–4<br>N/A<br>N/A<br>1<br>Cu/Al<br>14–8<br>N/A<br>N/A<br>1<br>Cu<br>14–8<br>N/A<br>N/A|
||||–40||||||
||||–30||||||
|QUICKLAG Type C<br>QC, QCHW,<br>QHCX, QHCW<br>10<br>25<br>70|||–20||5<br>Cu/Al|TBD||5<br>Cu/Al<br>14–10<br>6, 7<br>6, 7, 8|
||||–60||6<br>Cu/Al|TBD||2<br>Cu/Al<br>14–4<br>5, 7<br>5, 6, 7, 8|
||||–100||7<br>Cu/Al|TBD||3<br>Cu/Al<br>8–1/0<br>5<br>5, 7, 8|
|QUICKLAG<br>QCR, QCF<br>10<br>60|||–55||1<br>Cu/Al|TBD||1<br>Cu/Al<br>14–4<br>N/A<br>N/A|
||||||1<br>Cu|TBD||1<br>Cu<br>14–4<br>N/A<br>N/A|
|QUICKLAG ground fault<br>QCGFT, QCGFEP,<br>QCHGFT, QCHGFEP<br>10<br>25<br>10|||–20||6<br>Cu/Al|TBD||14–8<br>Cu/Al<br>14–4<br>6, 7<br>5|
||||–50||6<br>Cu/Al|TBD||1<br>Cu/Al<br>14–4<br>5, 7<br>5|
||||–30||6<br>—|—||—<br>—<br>—<br>—<br>—|
|QUICKLAG<br>QCD||10<br>70|–60||9<br>Cu/Al|14–4||9<br>Cu/Al<br>14–4<br>See Accessories|
||||–100||10<br>Cu|4–1/0||10<br>Cu<br>4–1/0<br>See Accessories|
|**1**<br>**6**<br>**S**<br>**Alu**||**2**<br>**7**<br>**g**|||||||
||**teel Box Lu**||**Steel Box Lug**||||||
||||||||||
||**minum Box**|**Lug**<br>**Al**|**uminum Bo**||||||
## _**Note**_
> 1 Clamp on line side only.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-47**
Miniature Circuit Breakers and Supplementary Protectors
1.1
Industrial Circuit Breakers
**1**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Shipping Data**
|**Shipping Data**|||||
|---|---|---|---|---|
|**Miniature**|**Number**|**Standard**<br>**Carton**|**Approximate**<br>**Carton Weight**|**Approximate Standard**|
|**Circuit Breaker**<br>QUICKLAG Types B, P, C–all|**of Poles**<br>1|**Quantity**<br>24|**Lbs (kg)**<br>9.00 (4.1)|**Carton**<br>12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|QUICKLAG Types B, P, C–all|2|12|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|QUICKLAG Types B, P, C–all|3|8|9.00 (4.1)|12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)|
|QUICKLAG ground fault Type P–all|1|20|11.00 (5.0)|12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)|
|Types B and C–all<br>Types P and B–all|1<br>2|20<br>5|11.00 (5.0)<br>5.00 (2.3)|12.50 x 7.00 x 5.50 (317.5 x 177.8 x 139.7)<br>12.50 x 6.00 x 4.50 (317.5 x 152.4 x 114.3)|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-48**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **FAZ-NA Circuit Breakers**
## **Contents**
**1**
_**Description Page**_ FAZ-NA Circuit Breakers Catalog Number Selection . . . . . . . . . . . . . . . . **V4-T1-50** Product Selection . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-51** Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-55** Technical Data and Specifications . . . . . . . . . . **V4-T1-57** Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-66**
**==> picture [155 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optimum and Efficient Protection for Every Application<br>**----- End of picture text -----**<br>
## **FAZ-NA Circuit Breakers**
## **Product Overview**
## **Features**
Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton’s FAZ-NA DIN rail mountable circuit breaker is designed for use in branch service applications.
- Complete range of UL 489 listed DIN rail mounted miniature circuit breakers up to 40A current rating
- SWD (switching duty)— suitable for switching fluorescent lighting loads (In ≤ 20A)
- Standard ratings of 10 kAIC up to 277/480 Vac
- Fulfill UL 489, CSA C22.2 No.5 and also IEC 60947-2 Standard
- Select amperages available at 14 kAIC up to 277/480 ● For use in applications for Vac and 10 kAIC up to 125 which UL 1077 or CSA Vdc per pole C22.2 No.235 are also
- ● allowed
## _**Powerful Offering for Machine and System Builders**_
- Current limiting design provides fast short-circuit ● Field-installable shunt trip interruption that reduces and auxiliary switch the let-through energy, subsequent mounting which can damage the ● Separate version for ringcircuit
The FAZ-NA is available with B, C and D characteristics in accordance with UL[®] 489, CSA[®] C22.2 No.5; UL 1077, CSA C22.2 No.235 and IEC 60947-2. These devices are CE marked.
- Separate version for ringtongue connection (Type FAZ-RT), terminal screws can be removed (on both sides)
- Suitable for branch circuit device protection
## **Application Description**
- Thermal-magnetic overcurrent protection ● Module width of only ● Three levels of short17.7 mm (per pole)
Feeder and branch circuit protection for:
- Three levels of shortcircuit protection, categorized by B, C and D curves
- Contact Position Indicator (red/green)
- Convenience receptacle circuits (internal/external)
- Easy installation on DIN rail
- Motor control circuits
- Trip-free design—breaker can not be defeated by holding the handle in the ON position
- Possibility for sealing the toggle in ON or OFF position
- Load circuits leaving the equipment (external)
- HACR internal/external ON position equipment (heating, air ● Captive screws cannot conditioning, refrigeration) be lost
## _**Device Printing on Front and Side**_ **Installation options**
These branch circuit breakers are available in two terminal configurations: standard box terminals that accept multiple conductors and ring-tongue terminals, ideally suited to demanding requirements of the semi-conductor industry. All breakers mount on standard 35 mm DIN rail. Bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies. These circuit breakers can also be reverse feed.
- PLC I/O points
- Computers
- Power supplies
- Control instrumentation
- Relays
- UPS
- Power conditioners
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-49**
Miniature Circuit Breakers and Supplementary Protectors
**1** ~~a~~
## 1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **Standards and Certifications**
FAZ-NA complies with ● RoHS compliant the latest national and ● VDE compliant international standards.
- ABS compliant
- UL 489
- Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection
- Products meet the requirements of the National Electrical Code[®] (NEC[®] )
- CSA C22.2 No.5
- Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection (corresponds closely to UL 489 Standard)
- Products meet the requirements of the Canadian Electrical Code (CEC)
## **Catalog Number Selection**
**==> picture [478 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
FAZ C 6 / 1 NA SP<br>Breaker Family Single Package<br>FAZ = FAZ UL Trip Terminal SP = Single package for<br>circuit breaker Characteristics [1] Ampere Rating [2] Number of Poles NA = UL 489 branch C and D curve<br>B = 3–5X In 0.5 = 0.5A 10 = 10A 1 = Single-pole circuit with screw single-pole only<br>CD = 5–10X I = 10–20X In n 11.5 == 1A1.5A 1315 = 13A = 15A 23 = Two-pole = Three-pole RT = UL 489 branch terminals Blank = Standard packaging<br>— 2 = 2A 16 = 16A ——— circuit with ring<br>3 = 3A 20 = 20A tongue terminals<br>4 = 4A 25 = 25A DC = UL 489 branch<br>5 = 5A 30 = 30A circuit at 125 Vdc<br>6 = 6A 32 = 32A per pole<br>7 = 7A 35 = 32A<br>8 = 8A 40 = 40A<br>**----- End of picture text -----**<br>
_**Notes**_
- 1 In = Rated current for instantaneous trip characteristics.
- 2 B curve starts at 1 ampere.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-50**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **Product Selection**
## _**FAZ-NA B Curve**_
- UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers
- Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2
- Current limiting device
- UL file number E235139
**==> picture [203 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 2<br>3600 Specified non-tripping 2.55 IN:<br>1200 yyHy current INT = 1.13 x IN for t > 1 h 0 t = 1–120 s (It = 1–60 s (IN N < 32A) > 32A)<br>600 aCe Specified tripping current 0 Type B: 3 x IN: t > 0.1 s<br>300 PVA IT = 1.45 x IN for t < 1 h 8 Type B: 5 x IN: t < 0.1 s<br>120<br>60 1<br>7 2<br>30<br>Pe<br>10<br>i SEeel<br>5<br>PTeT<br>2 ae7<br>1 1 ma77<br>0.5<br>0.2 Y<br>0.050.1 77 2 B | 3<br>77|<br>0.02<br>0.01 ae7)<br>0.005<br>0.002<br>0.001 a<br>0.0005 a<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
**1**
**FAZ-NA UL 489 Circuit Breakers—10 kAIC, Single-Pole 14 kAIC B Curve (15–25A)**
||**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**|||||
|---|---|---|---|---|---|---|
|**Single-Pole**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**<br>**14 kAIC B Curve (15–25A)**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**|**Single-Pole**||**FAZ-RT UL 489 Circuit Breakers with**<br>**Ring-Tongue Terminals—10 kAIC, 14 kAIC**|**1**|
|**1**<br>**Single-Pole**1<br>**Two-Pole**<br>**Three-Pole**<br>**B Curve (15–25A)**<br>~~ww~~|||||||
||**Catalog**<br>**Catalog**|**Catalog**|||**Single-Pole**1<br>**Two-Pole**<br>**Three-Pole**||
||**Amperes**<br>**Number**<br>**Number**<br>**B Curve (3–5X In Current Rating)**|**Number**|||**Amperes**<br>**Catalog**<br>**Number**<br>**Catalog**<br>**Number**<br>**Catalog**<br>**Number**|**1**|
|1<br>**FAZ-B1/1-NA**<br>**FAZ-B1/2-NA**<br>**FAZ-B1/3-NA**<br>1.5<br>**FAZ-B1.5/1-NA FAZ-B1.5/2-NA FAZ-B1.5/3-NA**<br>2<br>**FAZ-B2/1-NA**<br>**FAZ-B2/2-NA**<br>**FAZ-B2/3-NA**<br>3<br>**FAZ-B3/1-NA**<br>**FAZ-B3/2-NA**<br>**FAZ-B3/3-NA**<br>4<br>**FAZ-B4/1-NA**<br>**FAZ-B4/2-NA**<br>**FAZ-B4/3-NA**<br>5<br>**FAZ-B5/1-NA**<br>**FAZ-B5/2-NA**<br>**FAZ-B5/3-NA**<br>**Two-Pole**<br>**Two-Pole**<br>~~B~~<br>3B<br>°|| ~~TT~~<br>°|a|||||**B Curve with Ring-Tongue Terminals**<br>**(3–5X In Current Rating)**<br>1<br>**FAZ-B1/1-RT**<br>**FAZ-B1/2-RT**<br>**FAZ-B1/3-RT**<br>1.5<br>**FAZ-B1.5/1-RT**<br>**FAZ-B1.5/2-RT**<br>**FAZ-B1.5/3-RT**<br>2<br>**FAZ-B2/1-RT**<br>**FAZ-B2/2-RT**<br>**FAZ-B2/3-RT**<br>3<br>**FAZ-B3/1-RT**<br>**FAZ-B3/2-RT**<br>**FAZ-B3/3-RT**<br>4<br>**FAZ-B4/1-RT**<br>**FAZ-B4/2-RT**<br>**FAZ-B4/3-RT**<br>~~a~~<br>| ~~ee~~|**1**<br>**1**<br>**1**<br>**1**|
||6<br>**FAZ-B6/1-NA**<br>**FAZ-B6/2-NA**<br>7<br>**FAZ-B7/1-NA**<br>**FAZ-B7/2-NA**|**FAZ-B6/3-NA**<br>**FAZ-B7/3-NA**|||5<br>**FAZ-B5/1-RT**<br>**FAZ-B5/2-RT**<br>**FAZ-B5/3-RT**<br>6<br>**FAZ-B6/1-RT**<br>**FAZ-B6/2-RT**<br>**FAZ-B6/3-RT**|**1**|
|Pip|8<br>**FAZ-B8/1-NA**<br>**FAZ-B8/2-NA**<br>10<br>**FAZ-B10/1-NA**<br>**FAZ-B10/2-NA**|**FAZ-B8/3-NA**<br>**FAZ-B10/3-NA**||Pp|7<br>**FAZ-B7/1-RT**<br>**FAZ-B7/2-RT**<br>**FAZ-B7/3-RT**<br>8<br>**FAZ-B8/1-RT**<br>**FAZ-B8/2-RT**<br>**FAZ-B8/3-RT**<br>~~a~~|**1**|
|**Three-Pole**<br>"|fey|13<br>**FAZ-B13/1-NA**<br>**FAZ-B13/2-NA**<br>15<br>**FAZ-B15/1-NA**<br>**FAZ-B15/2-NA**<br>16<br>**FAZ-B16/1-NA**<br>**FAZ-B16/2-NA**|**FAZ-B13/3-NA**<br>**FAZ-B15/3-NA**<br>**FAZ-B16/3-NA**||10<br>**FAZ-B10/1-RT**<br>**FAZ-B10/2-RT**<br>**FAZ-B10/3-RT**<br>13<br>**FAZ-B13/1-RT**<br>**FAZ-B13/2-RT**<br>**FAZ-B13/3-RT**<br>15<br>**FAZ-B15/1-RT**<br>**FAZ-B15/2-RT**<br>**FAZ-B15/3-RT**<br>**Three-Pole**<br>“|fey ~~OO~~||**1**<br>**1**|
|P\>\p|20<br>**FAZ-B20/1-NA**<br>**FAZ-B20/2-NA**<br>25<br>**FAZ-B25/1-NA**<br>**FAZ-B25/2-NA**<br>30<br>**FAZ-B30/1-NA**<br>**FAZ-B30/2-NA**<br>32<br>**FAZ-B32/1-NA**<br>**FAZ-B32/2-NA**|**FAZ-B20/3-NA**<br>**FAZ-B25/3-NA**<br>**FAZ-B30/3-NA**<br>**FAZ-B32/3-NA**||16<br>**FAZ-B16/1-RT**<br>**FAZ-B16/2-RT**<br>**FAZ-B16/3-RT**<br>20<br>**FAZ-B20/1-RT**<br>**FAZ-B20/2-RT**<br>**FAZ-B20/3-RT**<br>25<br>**FAZ-B25/1-RT**<br>**FAZ-B25/2-RT**<br>**FAZ-B25/3-RT**<br>30<br>**FAZ-B30/1-RT**<br>**FAZ-B30/2-RT**<br>**FAZ-B30/3-RT**<br>Ppp||**1**<br>**1**|
||352<br>**FAZ-B35/1-NA**<br>**FAZ-B35/2-NA**|**FAZ-B35/3-NA**|||32<br>**FAZ-B32/1-RT**<br>**FAZ-B32/2-RT**<br>**FAZ-B32/3-RT**|**1**|
||402<br>**FAZ-B40/1-NA**<br>**FAZ-B40/2-NA**|**FAZ-B40/3-NA**|||352<br>**FAZ-B35/1-RT**<br>**FAZ-B35/2-RT**<br>**FAZ-B35/3-RT**<br>402<br>**FAZ-B40/1-RT**<br>**FAZ-B40/2-RT**<br>**FAZ-B40/3-RT**|**1**|
## _**Notes**_
- 1 Two-piece order. Quantities of two per box.
- 2 240 Vac rated only.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-51**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## _**FAZ-NA C Curve**_
- **1** ● UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers
- Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2
- Current limiting device
- UL file number E235139
## **FAZ-NA UL 489 Circuit Breakers—10 kAIC, Single-Pole 14 kAIC C Curve (15–25A)**
|||**Single-Pole**1|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|
||**Amperes**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|
||**C Curve (5–10X I**|**C Curve (5–10X In Current Rating)**|**Current Rating)**||
||0.5|**FAZ-C0.5/1-NA-SP **|**FAZ-C0.5/2-NA **|**FAZ-C0.5/3-NA**|
|B|1|**FAZ-C1/1-NA-SP**|**FAZ-C1/2-NA**|**FAZ-C1/3-NA**|
|**Two-Pole**|1.5<br>2|**FAZ-C1.5/1-NA-SP **<br>**FAZ-C2/1-NA-SP**|**FAZ-C1.5/2-NA **<br>**FAZ-C2/2-NA**|**FAZ-C1.5/3-NA**<br>**FAZ-C2/3-NA**|
||3<br>4|**FAZ-C3/1-NA-SP**<br>**FAZ-C4/1-NA-SP**|**FAZ-C3/2-NA**<br>**FAZ-C4/2-NA**|**FAZ-C3/3-NA**<br>**FAZ-C4/3-NA**|
||5|**FAZ-C5/1-NA-SP**|**FAZ-C5/2-NA**|**FAZ-C5/3-NA**|
||6|**FAZ-C6/1-NA-SP**|**FAZ-C6/2-NA**|**FAZ-C6/3-NA**|
||7|**FAZ-C7/1-NA-SP**|**FAZ-C7/2-NA**|**FAZ-C7/3-NA**|
|**Three-Pole**<br>Bp|8<br>**FAZ-C8/1-NA-SP**<br>**FAZ-C8/2-NA**<br>10<br>**FAZ-C10/1-NA-SP FAZ-C10/2-NA **<br>~~TT~~|||**FAZ-C8/3-NA**<br> **FAZ-C10/3-NA**<br>~~€~~|
|tks|13<br>15|**FAZ-C13/1-NA-SP **<br>**FAZ-C15/1-NA-SP **|**FAZ-C13/2-NA **<br> **FAZ-C15/2-NA **|**FAZ-C13/3-NA**<br> **FAZ-C15/3-NA**|
||16|**FAZ-C16/1-NA-SP **|**FAZ-C16/2-NA **|**FAZ-C16/3-NA**|
|Sisis,|20<br>25<br>30<br>32|**FAZ-C20/1-NA-SP **<br>**FAZ-C25/1-NA-SP **<br>**FAZ-C30/1-NA-SP **<br>**FAZ-C32/1-NA-SP **|**FAZ-C20/2-NA **<br> **FAZ-C25/2-NA **<br> **FAZ-C30/2-NA **<br> **FAZ-C32/2-NA **|**FAZ-C20/3-NA**<br> **FAZ-C25/3-NA**<br> **FAZ-C30/3-NA**<br> **FAZ-C32/3-NA**|
||352|**FAZ-C35/1-NA-SP **|**FAZ-C35/2-NA **|**FAZ-C35/3-NA**|
||402|**FAZ-C40/1-NA-SP **|**FAZ-C40/2-NA **|**FAZ-C40/3-NA**|
**==> picture [192 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200<br>3600 Specified non-tripping Type C: 5 x IN: t > 0.1 s<br>1200 ry currentINT = 1.13 x IN for t > 1 h : Type C: 10 x IN: t < 0.1 s<br>600300 VomVv Specified tripping currentIT = 1.45 x IN for t < 1 h<br>120<br>60<br>A,<br>30<br>Cs<br>10 7SE<br>5<br>PT pe<br>2<br>1 1<br>0.5<br>i]<br>0.2<br>0.1 2<br>0.05 1 C<br>277<br>0.02<br>0.01<br>0.0020.005 SH l eeeL Tp<br>0.001<br>0.0005 a<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
**FAZ-RT UL 489 Circuit Breakers with Ring-Tongue Terminals—10 kAIC, 14 kAIC C Curve (15–25A)**
## **Single-Pole**
||||**Single-Pole**1|**Two-Pole**|**Three-Pole**|
|---|---|---|---|---|---|
||||**Catalog**|**Catalog**|**Catalog**|
|||**Amperes**|**Number**|**Number**|**Number**|
|||**C Curve with Ring-Tongue Terminals**||||
|3B||**(5–10X In Current Rating)**<br>0.5<br>**FAZ-C0.5/1-RT-SP FAZ-C0.5/2-RT FAZ-C0.5/3-RT**<br>~~OO~~||||
|**Two-Pole**||1|**FAZ-C1/1-RT-SP**|**FAZ-C1/2-RT**|**FAZ-C1/3-RT**|
|||1.5|**FAZ-C1.5/1-RT-SP **|**FAZ-C1.5/2-RT **|**FAZ-C1.5/3-RT**|
|||2|**FAZ-C2/1-RT-SP**|**FAZ-C2/2-RT**|**FAZ-C2/3-RT**|
|||3|**FAZ-C3/1-RT-SP**|**FAZ-C3/2-RT**|**FAZ-C3/3-RT**|
|||4|**FAZ-C4/1-RT-SP**|**FAZ-C4/2-RT**|**FAZ-C4/3-RT**|
|||5|**FAZ-C5/1-RT-SP**|**FAZ-C5/2-RT**|**FAZ-C5/3-RT**|
|P\p||6<br>**FAZ-C6/1-RT-SP**<br>**FAZ-C6/2-RT**<br>**FAZ-C6/3-RT**<br>7<br>**FAZ-C7/1-RT-SP**<br>**FAZ-C7/2-RT**<br>**FAZ-C7/3-RT**<br> ~~a~~||||
|**Three-Pole**||||||
|||8|**FAZ-C8/1-RT-SP**|**FAZ-C8/2-RT**|**FAZ-C8/3-RT**|
|reas|10<br>**FAZ-C10/1-RT-SP**<br>**FAZ-C10/2-RT FAZ-C10/3-RT**<br>13<br>**FAZ-C13/1-RT-SP**<br>**FAZ-C13/2-RT FAZ-C13/3-RT**<br> ~~i.~~|||||
|||15|**FAZ-C15/1-RT-SP**|**FAZ-C15/2-RT **|**FAZ-C15/3-RT**|
|||16|**FAZ-C16/1-RT-SP**|**FAZ-C16/2-RT **|**FAZ-C16/3-RT**|
|Bie||20<br>25|**FAZ-C20/1-RT-SP**<br>**FAZ-C25/1-RT-SP**|**FAZ-C20/2-RT **<br>**FAZ-C25/2-RT **|**FAZ-C20/3-RT**<br> **FAZ-C25/3-RT**|
|||30|**FAZ-C30/1-RT-SP**|**FAZ-C30/2-RT **|**FAZ-C30/3-RT**|
|||32|**FAZ-C32/1-RT-SP**|**FAZ-C32/2-RT **|**FAZ-C32/3-RT**|
|||352|**FAZ-C35/1-RT-SP**|**FAZ-C35/2-RT **|**FAZ-C35/3-RT**|
|||402|**FAZ-C40/1-RT-SP**|**FAZ-C40/2-RT **|**FAZ-C40/3-RT**|
## _**Notes**_
- 1 Option for single packaging on single-pole C and D curves only; add suffix SP when ordering.
- 2 240 Vac rated only.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-52**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## _**FAZ-NA D Curve**_
- UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers
- Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2
- Current limiting device
- UL file number E235139
|**Single-Pole**|**Single-Pole**|**Single-Pole**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**<br>**14 kAIC D Curve (13–20A)**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**<br>**14 kAIC D Curve (13–20A)**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**<br>**14 kAIC D Curve (13–20A)**|**FAZ-NA UL 489 Circuit Breakers—10 kAIC,**<br>**14 kAIC D Curve (13–20A)**|
|---|---|---|---|---|---|---|
|||||**Single-Pole**1|**Two-Pole**|**Three-Pole**|
|||||**Catalog**|**Catalog**|**Catalog**|
||||**Amperes**|**Number**|**Number**|**Number**|
||||**D Curve (10–20X In Current Rating)**||||
||||0.5|**FAZ-D0.5/1-NA-SP **|**FAZ-D0.5/2-NA FAZ-D0.5/3-NA**|**FAZ-D0.5/2-NA FAZ-D0.5/3-NA**|
||||1|**FAZ-D1/1-NA-SP**|**FAZ-D1/2-NA**|**FAZ-D1/3-NA**|
||**Two-Pole**||1.5|**FAZ-D1.5/1-NA-SP **|**FAZ-D1.5/2-NA FAZ-D1.5/3-NA**|**FAZ-D1.5/2-NA FAZ-D1.5/3-NA**|
||||2|**FAZ-D2/1-NA-SP**|**FAZ-D2/2-NA**|**FAZ-D2/3-NA**|
||||3|**FAZ-D3/1-NA-SP**|**FAZ-D3/2-NA**|**FAZ-D3/3-NA**|
||re|“a|4<br>5|**FAZ-D4/1-NA-SP**<br>**FAZ-D5/1-NA-SP**|**FAZ-D4/2-NA**<br>**FAZ-D5/2-NA**|**FAZ-D4/3-NA**<br>**FAZ-D5/3-NA**|
||||6|**FAZ-D6/1-NA-SP**|**FAZ-D6/2-NA**|**FAZ-D6/3-NA**|
||||7|**FAZ-D7/1-NA-SP**|**FAZ-D7/2-NA**|**FAZ-D7/3-NA**|
||||8|**FAZ-D8/1-NA-SP**|**FAZ-D8/2-NA**|**FAZ-D8/3-NA**|
||**Three-Pole**||10|**FAZ-D10/1-NA-SP **|**FAZ-D10/2-NA **|**FAZ-D10/3-NA**|
||||13|**FAZ-D13/1-NA-SP **|**FAZ-D13/2-NA **|**FAZ-D13/3-NA**|
||||15|**FAZ-D15/1-NA-SP **|**FAZ-D15/2-NA **|**FAZ-D15/3-NA**|
||||16|**FAZ-D16/1-NA-SP **|**FAZ-D16/2-NA **|**FAZ-D16/3-NA**|
||||20|**FAZ-D20/1-NA-SP **|**FAZ-D20/2-NA **|**FAZ-D20/3-NA**|
||||25|**FAZ-D25/1-NA-SP **|**FAZ-D25/2-NA **|**FAZ-D25/3-NA**|
||Ppp||30|**FAZ-D30/1-NA-SP **|**FAZ-D30/2-NA **|**FAZ-D30/3-NA**|
||||32|**FAZ-D32/1-NA-SP **|**FAZ-D32/2-NA **|**FAZ-D32/3-NA**|
||||352|**FAZ-D35/1-NA-SP **|**FAZ-D35/2-NA **|**FAZ-D35/3-NA**|
||||402|**FAZ-D40/1-NA-SP **|**FAZ-D40/2-NA **|**FAZ-D40/3-NA**|
**==> picture [195 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200<br>3600 Specified non-tripping 2.55 IN:<br>1200 aa currentINT = 1.13 x IN for t > 1 h 0 t = 1–120 s (It = 1–60 s (IN N < 32A) > 32A)<br>600300 “a= Specified tripping currentIT = 1.45 x IN for t < 1 h , Type D: 10 x IType D: 20 x INN: t > 0.1 s: t < 0.1 s<br>120<br>60 Oo 1 LP<br>30<br><n<br>10<br>eZ Aeee<br>5 Pe<br>2<br>1<br>1<br>0.5<br>0.2<br>0.1 3<br>0.05 -—t 2 D<br>esae<br>0.02 a ee 77|<br>0.01 77<br>0.005<br>0.002<br>0.001 NZ<br>0.0005 a<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
|**Single-Pole**|**Single-Pole**|**FAZ-RT UL 489 Circuit Breakers with**<br>**Ring-Tongue Terminals—10 kAIC, 14 kAIC**<br>**D Curve (13–20A)**|**FAZ-RT UL 489 Circuit Breakers with**<br>**Ring-Tongue Terminals—10 kAIC, 14 kAIC**<br>**D Curve (13–20A)**|**FAZ-RT UL 489 Circuit Breakers with**<br>**Ring-Tongue Terminals—10 kAIC, 14 kAIC**<br>**D Curve (13–20A)**|**FAZ-RT UL 489 Circuit Breakers with**<br>**Ring-Tongue Terminals—10 kAIC, 14 kAIC**<br>**D Curve (13–20A)**|
|---|---|---|---|---|---|
||||**Single-Pole**1<br>**Catalog**|**Two-Pole**<br>**Catalog**|**Three-Pole**<br>**Catalog**|
|||**Amperes**<br>**D Curve with Ring-Tongue Terminals**|**Number**<br>**Number**<br>**D Curve with Ring-Tongue Terminals**||**Number**|
|||**(10–20X I**<br>0.5|**(10–20X In Current Rating)**<br>**FAZ-D0.5/1-RT-SP FAZ-D0.5/2-RT **||**FAZ-D0.5/3-RT**|
|**Two-Pole**||1<br>1.5|**FAZ-D1/1-RT-SP**<br>**FAZ-D1.5/1-RT-SP **|**FAZ-D1/2-RT**<br> **FAZ-D1.5/2-RT **|**FAZ-D1/3-RT**<br> **FAZ-D1.5/3-RT**|
|re|“a|2<br>**FAZ-D2/1-RT-SP**<br>**FAZ-D2/2-RT**<br>**FAZ-D2/3-RT**<br>3<br>**FAZ-D3/1-RT-SP**<br>**FAZ-D3/2-RT**<br>**FAZ-D3/3-RT**<br>4<br>**FAZ-D4/1-RT-SP**<br>**FAZ-D4/2-RT**<br>**FAZ-D4/3-RT**<br> ~~SS~~||||
|||5<br>6|**FAZ-D5/1-RT-SP**<br>**FAZ-D6/1-RT-SP**|**FAZ-D5/2-RT**<br>**FAZ-D6/2-RT**|**FAZ-D5/3-RT**<br>**FAZ-D6/3-RT**|
|**Three-Pole**||7|**FAZ-D7/1-RT-SP**|**FAZ-D7/2-RT**|**FAZ-D7/3-RT**|
|||8|**FAZ-D8/1-RT-SP**|**FAZ-D8/2-RT**|**FAZ-D8/3-RT**|
|||10|**FAZ-D10/1-RT-SP **|**FAZ-D10/2-RT**|**FAZ-D10/3-RT**|
|||13|**FAZ-D13/1-RT-SP **|**FAZ-D13/2-RT**|**FAZ-D13/3-RT**|
|||15|**FAZ-D15/1-RT-SP **|**FAZ-D15/2-RT**|**FAZ-D15/3-RT**|
|||16<br>20|**FAZ-D16/1-RT-SP **<br>**FAZ-D20/1-RT-SP **|**FAZ-D16/2-RT**<br> **FAZ-D20/2-RT**|**FAZ-D16/3-RT**<br>**FAZ-D20/3-RT**|
|Ppp||25|**FAZ-D25/1-RT-SP **|**FAZ-D25/2-RT**|**FAZ-D25/3-RT**|
|||30|**FAZ-D30/1-RT-SP **|**FAZ-D30/2-RT**|**FAZ-D30/3-RT**|
|||32|**FAZ-D32/1-RT-SP **|**FAZ-D32/2-RT**|**FAZ-D32/3-RT**|
|||352|**FAZ-D35/1-RT-SP **|**FAZ-D35/2-RT**|**FAZ-D35/3-RT**|
|||402|**FAZ-D40/1-RT-SP **|**FAZ-C40/2-RT**|**FAZ-D40/3-RT**|
**1**
## _**Notes**_
- 1 Option for single packaging on single-pole C and D curves only; add suffix SP when ordering.
- 2 240 Vac rated only.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-53**
Miniature Circuit Breakers and Supplementary Protectors
**1** ~~—_~~
## 1.2
UL 489 DIN Rail Miniature Circuit Breakers
## _**FAZ-NA-DC C Curve**_
- UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as Branch Circuit Breakers
- Interrupting capacity: 10 kA at 125 Vdc UL/CSA, 10 kA at 250 Vdc
- 125 Vdc for one-pole, 250 Vdc for two-pole in series
- Current limiting device
- Polarity (+/–) sensitive and not for use on photovoltaic string application
- UL file number E235139
## **FAZ-NA-DC UL 489 Circuit Breakers— Single-Pole 10 kAIC at 125 Vdc Per Pole**
## **Two-Pole**
||**Single-Pole**1|**Two-Pole**|
|---|---|---|
||**Catalog**|**Catalog**|
|**Amperes**|**Number**|**Number**|
|**C Curve (5–10X I**|**C Curve (5–10X In Current Rating)**||
|2|**FAZ-C2/1-NA-DC-SP**|**FAZ-C2/2-NA-DC**|
|3<br>4|**FAZ-C3/1-NA-DC-SP**<br>**FAZ-C4/1-NA-DC-SP**|**FAZ-C3/2-NA-DC**<br>**FAZ-C4/2-NA-DC**|
|5|**FAZ-C5/1-NA-DC-SP**|**FAZ-C5/2-NA-DC**|
|6|**FAZ-C6/1-NA-DC-SP**|**FAZ-C6/2-NA-DC**|
|7|**FAZ-C7/1-NA-DC-SP**|**FAZ-C7/2-NA-DC**|
|8|**FAZ-C8/1-NA-DC-SP**|**FAZ-C8/2-NA-DC**|
|10|**FAZ-C10/1-NA-DC-SP**|**FAZ-C10/2-NA-DC**|
|13<br>15|**FAZ-C13/1-NA-DC-SP**<br>**FAZ-C15/1-NA-DC-SP**|**FAZ-C13/2-NA-DC**<br>**FAZ-C15/2-NA-DC**|
|16|**FAZ-C16/1-NA-DC-SP**|**FAZ-C16/2-NA-DC**|
|20|**FAZ-C20/1-NA-DC-SP**|**FAZ-C20/2-NA-DC**|
|25|**FAZ-C25/1-NA-DC-SP**|**FAZ-C25/2-NA-DC**|
|30<br>32|**FAZ-C30/1-NA-DC-SP**<br>**FAZ-C32/1-NA-DC-SP**|**FAZ-C30/2-NA-DC**<br>**FAZ-C32/2-NA-DC**|
|35|**FAZ-C35/1-NA-DC-SP**|**FAZ-C35/2-NA-DC**|
|40|**FAZ-C40/1-NA-DC-SP**|**FAZ-C40/2-NA-DC**|
## _**Note**_
- 1 Option for single packaging on single-pole C curves only; add suffix SP when ordering.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-54**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **Accessories**
**1**
||||**FAZ-NA UL 489 Breakers**|**FAZ-NA UL 489 Breakers**|||||||||||||||||||||**FAZ-NA UL 489 Breakers, continued**|**FAZ-NA UL 489 Breakers, continued**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||**Description**|**Catalog Number**|||||||||||||||||||||**Description**|**Catalog Number**|
|**Contact**|||Two-pole contact or auxiliary|**Z-NHK**1|**Busbar**||||||||||||||||||||Busbar—single-pole, 6 terminals2345|**Z-SV/UL-16/1P-1TE/6**|
||||contact/trip indicating contact||||||||||||||||||||||Busbar—single-pole, 12 terminals2345|**Z-SV/UL-16/1P-1TE/12**|
||||||||||||||||||||||||||Busbar—single-pole, 18 terminals2345 <br>Busbar—two-pole, 6 terminals2345|**Z-SV/UL-16/1P-1TE/18**<br>**Z-SV/UL-16/2P-2TE/6**|
||||||||||||||||||||||||||Busbar—two-pole, 12 terminals2345<br>**Z-SV/UL-16/2P-2TE/12**<br>Busbar—two-pole, 18 terminals2345<br>**Z-SV/UL-16/2P-2TE/18**<br>~~OO~~||
||||||||||||||||||||||||||Busbar—three-pole, 6 terminals2345|**Z-SV/UL-16/3P-3TE/6**|
|**Auxiliary Contact**||**Auxiliary Contact**|Auxiliary contact|**Z-IHK-NA**|||||||||||||||||||||Busbar—three-pole, 12 terminals2345 <br>Busbar—three-pole, 18 terminals2345|**Z-SV/UL-16/3P-3TE/12**<br> **Z-SV/UL-16/3P-3TE/18**|
||||||**Busbar Shroud**|||||||||**Busbar Shroud**|||||||||||Three-pole busbar shroud|**ZV-BS-UL**|
|Shunt trip 110–415 Vac<br>**FAZ-XAA-NA110-415VAC**<br>Shunt trip 12–110 Vac<br>**FAZ-XAA-NA12-110VAC**<br>**Shunt Trip**<br>w<br>~~a~~<br>)<br>~~a~~|||||**Extension Terminal**<br>~~o~~h).<br>N~~ic~~<br>c\||||||||||||||||||||Extension terminal—<br>35 mm2(10–1/0 AWG)|**Z-EK/35/UL**|
|**Padlock Hasp**|||Padlock hasp|**Z-IS/SPE-1TE**|||||||||||||||||||||||
||||||||||||||||||||||||||||
||t-||||**Bus Connector**||||||||||||||||||||Bus connector—conductors up to<br>50 mm2(~1/0 AWG)<br>**Z-EB/50/UL**<br>~~Oo~~||
|**Lockoff Device**|||UL lockoff device|**FAZPLOFF**|**_Notes_**||||||||||||||||||||||
- 1 Voltage of FAZ-NA circuit breaker is limited to 300V with this auxiliary contact installed.
- 2 Do not cut commoning link.
- 3 A maximum of three commoning links may be used in conjunction. Each breaker connected to the commoning link must have the same number of poles for proper use.
- 4 Not for use with ring-tongue circuit breakers.
- 5 Bus may be center fed for high current capacity.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-55**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## _**Tripping Signal Switch Z-NHK, Z-IHK-NA**_
- **1** ● Design according to IEC/EN 60947-5-1, IEC/EN 62019
- Field installable
- The specified minimum voltages are per contact—take into account particularly in case of series connection
- Self-cleaning contacts
- Contact material and design particularly suitable for extra low voltage
- Z-NHK: the function of one of the two change-over contacts can be switched from “auxiliary switch” to “tripping signal switch”
- Tripping signal contact transmits message of electric tripping, not mechanical switch-off
- Test key for contact function “electrical tripping”
- Z-IHK-NA: will allow for > 480Y/277 Vac rating
## **Connection Diagram**
**==> picture [194 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
Z-NHK Z-IHK-NA<br>4.14/4.12 21<br>4.12/4.14<br>13<br>4.11<br>|<br>14<br>22<br>1.11<br>1.14 Same Polarity<br>1.12<br>**----- End of picture text -----**<br>
## **Busbar Connection Example**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-56**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
**1**
## **Technical Data and Specifications**
## _**Trip Curve Chart**_
Eaton FAZ-NA branch circuit breakers are available with “B,” “C” and “D” tripping characteristics. B-curve devices are suitable for applications where low levels of inrush current are expected.
C-curve devices are suitable for applications where medium levels of inrush current are expected. Applications include small transformers, lighting, pilot devices, control circuits and coils. C-curve devices provide a medium magnetic trip point.
D-curve devices are suitable for applications where high levels of inrush current are expected. The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
Eaton FAZ-NA devices are current limiting, which means they interrupt fault currents within one half cycle of the fault. Current limiting devices offer superior protection by reducing peak let-through current and energy.
## **Tripping Characteristics**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-57**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
|**1**<br>**1**<br>~~as~~|**Connection Diagrams**<br>Single-Pole|**Connection Diagrams**<br>Single-Pole|**Connection Diagrams**<br>Single-Pole|**Connection Diagrams**<br>Single-Pole|**Miniature Circuit Breakers FAZ-NA Technical Data**<br>**Description**<br>**Specification**<br>**Electrical**<br>~~Be~~|**Miniature Circuit Breakers FAZ-NA Technical Data**<br>**Description**<br>**Specification**<br>**Electrical**<br>~~Be~~|
|---|---|---|---|---|---|---|
||||1||Design according to<br>UL 489, CSA C22.2 No.5, IEC 60947-2<br> ~~Te~~||
|**1**<br>**1**<br>**1**<br>**1**|||:2||Rated voltage FAZ-NA<br>UL/CSA<br>UL/CSA<br>UL/CSA<br>IEC 947-2<br>Rated voltage FAZ-NA-DC<br>~~CO~~|10 kAIC at 277/480V from 0.5A to 32A<br>14 kAIC at select amperages<br>B and C Curves (15–25A), D Curve (13–20A)<br>10 kAIC at 240 Vac for 35A and 40A<br>10 kAIC at 48 Vdc per pole<br>15 kAIC at 240/415 Vac|
|**1**<br>**1**<br>**1**<br>**1**<br>**1**||Two-Pole<br>1<br>3 <br>oe~~Oe~~<br>2<br>4||<br>~~Oe~~<br>|UL/CSA<br>10 kAIC at 125 Vdc per pole (two poles maximum)<br>10 kAIC at 250 Vdc with two poles connected in series<br>Rated frequency<br>50/60 Hz<br>Characteristic<br>B, C, D<br>Endurance<br>≥ 20,000 operations<br>Line voltage connection<br>Suitable for reverse feed<br>**Mechanical**<br>Frame size<br>45 mm<br>Device height<br>105 mm<br> ~~SS TTT~~<br>~~Oe~~<br> ~~ee~~||
|**1**||Three-Pole|||Device width|17.7 mm per pole|
|**1**||1|$3 °5||Terminal protection<br>Mounting|Finger and hand touch safe according to BGV A3, OVE-EN 6<br>Quick fastening with two lock-in positions on IEC/EN 60715|
|**1**|||||Upper and lower terminals<br>Terminal capacity|Open mouth/lift terminals<br>One wire: AWG 18–6|
|||||||Two wires: AWG 18–10|
|**1**|||||Terminal fastening torque|AWG 18–21: 21 lb-in|
|||||||AWG 10–8: 25 lb-in|
|**1**||2|4|6||AWG 6: 36 lb-in|
||||||Mounting|Independent of position|
|**1**|||||Calibration temperature||
||||||UL 489, CSA C22.2 No.5|40°C|
|**1**|||||IEC 60947-2|30°C|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-58**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
|||
|---|---|
|**Power Loss at****_l_n**<br>**Characteristic B**<br>**Characteristic C**<br>**Characteristic D**<br>**Single-Pole**<br>**Two-Pole**<br>**Three-Pole**<br>**Single-Pole**<br>**Two-Pole**<br>**Three-Pole**<br>**Single-Pole**<br>**Two-Pole**<br>**Three-Pole**<br>**_I_n [A]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>**P [W]**<br>0.5<br>—<br>—<br>—<br>1.6<br>3.2<br>4.7<br>1.6<br>3.2<br>4.8<br>1.0<br>1.1<br>2.2<br>3.4<br>1.1<br>2.2<br>3.4<br>0.8<br>1.5<br>2.3<br>1.5<br>2.2<br>4.4<br>6.6<br>1.3<br>2.6<br>3.9<br>1.0<br>2.1<br>3.1<br>2.0<br>1.4<br>2.8<br>4.3<br>1.4<br>2.8<br>4.3<br>1.0<br>2.1<br>3.1<br>3.0<br>2.1<br>4.2<br>6.4<br>1.2<br>2.4<br>3.6<br>1.2<br>2.4<br>3.6<br>4.0<br>1.4<br>2.9<br>4.3<br>1.4<br>2.9<br>4.3<br>1.4<br>2.9<br>4.3<br>5.0<br>1.8<br>3.7<br>5.5<br>1.9<br>3.7<br>5.6<br>1.5<br>2.9<br>4.4<br>6.0<br>1.7<br>3.5<br>5.2<br>1.2<br>2.3<br>3.5<br>1.2<br>2.3<br>3.5<br>7.0<br>2.0<br>4.0<br>6.0<br>1.4<br>2.8<br>4.3<br>1.4<br>2.8<br>4.3<br>8.0<br>2.0<br>3.9<br>5.9<br>1.4<br>2.8<br>4.2<br>1.2<br>2.4<br>3.7<br>10.0<br>1.8<br>3.6<br>5.3<br>1.8<br>3.6<br>5.3<br>1.5<br>3.0<br>4.5<br>13.0<br>2.4<br>4.7<br>7.1<br>2.4<br>4.7<br>7.1<br>2.0<br>4.1<br>6.1<br>15.0<br>1.9<br>3.8<br>5.6<br>1.9<br>3.8<br>5.6<br>1.5<br>3.1<br>4.6<br>16.0<br>2.1<br>4.3<br>6.4<br>2.1<br>4.3<br>6.4<br>1.7<br>3.5<br>5.2<br>20.0<br>2.9<br>5.8<br>8.7<br>2.9<br>5.8<br>8.7<br>1.8<br>3.7<br>5.5<br>25.0<br>3.1<br>6.2<br>9.3<br>3.1<br>6.2<br>9.3<br>2.6<br>5.1<br>7.7<br>30.0<br>3.0<br>6.0<br>9.0<br>3.0<br>6.0<br>9.0<br>2.7<br>5.4<br>8.1<br>32.0<br>3.4<br>6.8<br>10.2<br>3.4<br>6.8<br>10.2<br>3.1<br>6.2<br>9.3<br>35.0<br>4.0<br>8.1<br>12.1<br>3.7<br>7.4<br>11.0<br>3.8<br>7.6<br>11.3<br>40.0<br>4.0<br>8.1<br>12.1<br>4.0<br>8.1<br>12.1<br>3.9<br>7.8<br>11.6|**1**|
||**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**<br>**1**|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-59**
1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers
**==> picture [11 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>**----- End of picture text -----**<br>
## _**Let-Through Energy**_
## **Characteristic B (1–32A), 277V**
## **Characteristic C (0.5–32A), 277V**
## **Characteristic B (35–40A), 240V**
## **Characteristic C (40A), 240V**
**V4-T1-60 Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
**1**
## **Characteristic D (0.5–32A), 277V**
## **Characteristic D (40A), 240V**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-61**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
**1**
## **Influence of Ambient Temperature T on Load Carrying Capacity**
**==> picture [461 x 266] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Device Market|In (A) at Higher Ambient Temperature|
|Current Rating In|
|(A) at 40°C|15°C|20°C|25°C|30°C|40°C|50°C|55°C|60°C|
|0.5|0.6|0.5|0.5|0.5|0.5|0.5|0.5|0.5|
|1.0|1.1|1.1|1.1|1.0|1.0|1.0|0.9|0.9|
|1.5|1.7|1.6|1.6|1.6|1.5|1.4|1.4|1.4|
|2.0|2.2|2.2|2.1|2.1|2.0|1.9|1.9|1.8|
|3.0|3.3|3.2|3.2|3.1|3.0|2.9|2.9|2.8|
|4.0|4.4|4.3|4.2|4.2|4.0|3.8|3.8|3.7|
|5.0|5.5|5.4|5.3|5.2|5.0|4.8|4.7|4.6|
|6.0|6.6|6.5|6.4|6.2|6.0|5.8|5.6|5.5|
|7.0|7.7|7.6|7.4|7.3|7.0|6.7|6.6|6.4|
|8.0|8.8|8.6|8.5|8.3|8.0|7.7|7.5|7.4|
|10.0|11.0|10.8|10.6|10.4|10.0|9.6|9.4|9.2|
|13.0|14.3|14.0|13.8|13.5|13.0|12.5|12.5|12.0|
|15.0|16.5|16.2|15.9|15.6|15.0|14.4|14.1|13.8|
|16.0|17.6|17.3|17.0|16.6|16.0|15.4|15.0|14.7|
|20.0|22.0|21.6|21.2|20.8|20.0|19.2|18.8|18.4|
|25.0|27.5|27.0|26.5|26.0|25.0|24.0|23.3|23.0|
|30.0|33.0|32.4|31.8|31.2|30.0|28.8|28.2|27.6|
|32.0|35.2|34.6|33.9|33.3|32.0|30.7|30.1|29.4|
|40.0|44.0|43.2|42.4|41.6|40.0|38.4|37.6|36.8|
**----- End of picture text -----**<br>
## **Load Carrying Capacity of Adjoining Miniature Circuit Breakers**
**==> picture [480 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.20 p—j—}rsf pf fp fp 1.00 NF ft tt<br>” | | | | | |:| | | | | | | | | | 0.90 NeaNN ee<br>| 0.80 ee eee<br>0.70<br>1 2 3 4 5 6 7 8<br>Number of Circuit Breakers<br>-20) -10 ia] 10 20 30 40 50 40<br> Ambient Temperature T [°C]<br>Maximum Load IL at ambient temperature T: IL (T) = IN KT(T)<br>]N<br>Rated Diversity Factor<br>Load Factor KT [I/I<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-62**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **Contact and Auxiliary Contact**
## **Z-NHK**
|**Z-NHK**||**Contact and Auxiliary Contact**|||
|---|---|---|---|---|
|||**Description**|**Z-NHK**|**Z-IHK-NA**|
|||**Electrical**<br>~~a~~|||
|=|8|Contact function|2CO|1NO + 1NC|
|||Rated voltage|230V|250V|
|Frequency<br>50/60 Hz<br>50/60 Hz<br>Rated current<br>2A<br>6A<br>Rated thermal current Ith<br>2A<br>6A<br>~~ee~~|||||
|**Z-IHK-NA**||Utilization category AC13|||
|||Rated operational current Ie|3A/250 Vac|3A/250 Vac|
|||Utilization category AC15|||
|||Rated operational current Ie<br>Utilization category DC12|2A/250 Vac|2A/250 Vac|
|||Rated operational current Ie|0.5A/110 Vdc|0.5A/110 Vdc<br>0.25A/220 Vdc|
|||Rated insulation voltage UI<br>Minimum operational voltage per contact Umin|250 Vac<br>5 Vdc|250 Vac<br>5 Vdc|
|||Minimum operational current Imin|10 mA DC|10 mA AC/DC|
|||Rated peak withstand voltage Uimp(1.2/50μ)|2.5 kV|4 kV|
|||Conditional short-circuit current Ikwith backup fuse 6A|1 kA|1 kA|
|||Max. backup fuse, overload and short circuit|6A gL|—|
|||**Mechanical**|||
|||Tripping indicator “electrical tripping”|Blue/white|—|
|||Frame size<br>Device height|45 mm<br>80 mm|45 mm<br>80 mm|
|||Device width|8.8 mm (0.5MU)|8.8 mm (0.5MU)|
|||Mounting|Onto switching device|—|
|||Degree of protection, built-in|IP40|IP40|
|||Terminal protection|Finger and hand touch safe<br>According to BGV A3, ÖVE-EN 6|Finger and hand touch safe<br>According to BGV A3, ÖVE-EN 6|
|||Terminals|Lift terminals|Lift terminals|
|||Terminal capacity|20–14 AWG|0.5–2.5 mm2|
|||Terminal screws<br>Fastening torque of terminal screws|M3 (Posidrive Z0)<br>7 lb-in|M3 (Posidrive Z0)<br>Max. 1.2 Nm|
**Z-IHK-NA**
**1**
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-63**
Miniature Circuit Breakers and Supplementary Protectors
UL 489 DIN Rail Miniature Circuit Breakers
## 1.2
**1**
## _**Shunt trip release FAZ-XAA-NA**_
- Remote release for subsequent mounting onto FAZ-NA/RT
- Additional installation of standard auxiliary switch is possible
- Position indicator red–green
## **Shunt Trip Release FAZ-XAA-NA**
|||||**Shunt Trip Release FAZ-XAA-NA**|**Shunt Trip Release FAZ-XAA-NA**|**Shunt Trip Release FAZ-XAA-NA**|
|---|---|---|---|---|---|---|
|**Connection Diagram**<br>1<br>O||||**Shunt Trip Release FAZ-XAA-NA**<br>**Description**<br>**FAZ-XAA-NA12-110VAC**<br>**FAZ-XAA-NA110-415VAC**<br> ~~se~~|||
|||||**Electrical**|||
||2<br>O|||Can be<br>mounted onto<br>Operational<br>voltage range|FAZ-NA / FAZ-NA-DC /<br>FAZ-RT<br>12–110 Vac<br>12–60 Vdc|FAZ-NA / FAZ-NA-DC /<br>FAZ-RT<br>110–415 Vac<br>110–230 Vdc|
|||||Frequency|50/60 Hz|50/60 Hz|
|||||**Mechanical**|||
|||||Frame size|45 mm|45 mm|
|||||Device height<br>Device width|105 mm<br>17.5 mm|105 mm<br>17.5 mm|
|||||Mounting|Quick fastening with two lock-in positions on EN 50022||
|||||Degree of protection, built-in|IP40|IP40|
|||||Terminal protection|Finger and hand touch safe according to BGV A3, ÖVE-EN 6||
|||||Terminals<br>Terminal capacity|Open mouthed/lift<br>18–10 AWG|Open mouthed/lift<br>18–10 AWG|
|||||One and two wires|||
## _**Busbar block UL 489 (pin)**_
- Tested according to UL 489
- Do not cut
- Extension terminal 35 mm[2] Z-EK/35/UL for copper conductors
- Incoming terminal 50 mm[2] Z-EB/50/UL
- For covering of not used pins, use busbar tag shrouds ZV-BS-UL
## **Busbar Block UL 489 (Pin)**
|**Busbar Block UL 489 (Pin)**<br>**Description**<br>**UL 489**<br>**IEC/EN 60947-2**<br>**Connection Diagrams**<br>Three-Pole Busbar|
|---|
|**Electrical**<br>Rated operational voltage<br>480/277 Vac<br>96 Vdc<br>—<br>Rated frequency<br>50/60 Hz<br>—<br>Rated voltage<br>480 Vac<br>690 Vac<br>Overvoltage category<br>—<br>III<br>Rated impulse withstand voltage Uimp<br>—<br>9.5 kV<br>Rated current<br>80A at 40°C<br>80A at 30°C<br>Rated conditional short-circuit current AC with 350A gG<br>—<br>15 kA<br>Short-circuit current<br>10 kA<br>—<br>**Mechanical**<br>Single-Pole Busbar<br>Two-Pole Busbar<br>Li~~—————~~<br>L3~~a~~<br>TT<br>Le<br>~~oo~~|
|Busbar cross section<br>—<br>16 mm2Cu<br>Flame class according to UL 94<br>V0<br>—<br>Pollution degree<br>—<br>2<br>Comparative tracking index<br>—<br>CTI 600<br>Minimum clearance (internal/external)<br>—<br>> 9.5/25.4 mm<br>iz L ~~TT~~|
|Minimum creepage distance (internal/external)<br>—<br>> 12.7/50.8 mm<br>Resistance to climatic conditions<br>—<br>According to|
|DIN/EN 60068|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-64**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
**1**
## _**Application Guidelines**_
## **Example of UL 489 and UL 1077 Application**
**==> picture [461 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
UL 489<br>Breaker<br>UL 489<br>UL 1077 Branch<br>Internal Receptacle External<br>Receptacle<br>Electronics<br>| UL 1077 ae UL 489 é<br>Branch External<br>Motor<br>Other<br>Sensitive M<br>Devices<br>UL 489<br>:<br>Branch<br>/ [Es] External<br>UL 489<br>Motor<br>Branch<br>M<br>Motor<br>UL 1077<br>HACR Controller<br>**----- End of picture text -----**<br>
**Example of UL 489 and UL 1077 Application**
## **UL 489 circuit breakers**
Used for branch circuit protection, internal/external receptacles, external motors and HACR equipment (heating, air conditioning and refrigeration).
## **UL 1077 supplementary protectors**
Used for overcurrent protection within appliances or electrical equipment, where branch circuit protection is already provided or not required.
**Note:** UL 489 devices can be used in place of UL 1077; UL 1077 devices cannot be used in place of UL 489.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-65**
Miniature Circuit Breakers and Supplementary Protectors
1.2
UL 489 DIN Rail Miniature Circuit Breakers
## **1** ~~oo~~
## **Dimensions**
Approximate Dimensions in Inches (mm)
**==> picture [478 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
Miniature Circuit Breakers Lockout Attachment— UL Lockoff Device—<br>Z-IS/SPE-1TE FAZPLOFF<br>Single-Pole Two-Pole Three-Pole<br>4.13 4.13 4.13<br>(105.0) be (105.0) 6 (105.0) d S )<br>f e] L ate’ «= felela} em Ba<br>.70 .70 .70 .70<br>(17.7) (17.7) (17.7)(17.7)<br>— rt 1.39 Po 2.09<br>(35.3) (53.1)<br>**----- End of picture text -----**<br>
## **Miniature Circuit Breakers**
## **Accessories**
**==> picture [441 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Z-SV/UL-16/6 Z-SV/UL-18...12 ZV-BS-UL<br>5x17,6=88 | — Hea?)<br>Z-SV/UL-16.../18 Z-EK/35/UL<br>**----- End of picture text -----**<br>
## **Z-EK/35/UL**
**Description UL 489 IEC/EN 60947-2** Ue 480 Vac/96 Vdc 240/415 Vac f 50/60 Hz 50/60 Hz Uimp — 9.5 kV Ie 80A at 40°C 80A at 30°C 10–1/0 AWG 60/75°C Cu 2.5–35 mm[2 ] Cu 0.56 in 14 mm ~~——— ©~~
## **Z-EB/50/UL**
**Description UL 489 IEC/EN 60947-2** Ue 480 Vac/96 Vdc 240/415 Vac f 50/60 Hz 50/60 Hz Uimp — 9.5 kV Ie 115A at 40°C 160A at 30°C #1–14 AWG 60/75°C Cu 1.5–50 mm[2 ] Cu 0.56 in 14 mm
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-66**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## **FAZ Circuit Breakers**
## **Contents**
## _**Description**_
_**Description Page**_ FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-67** Catalog Number Selection . . . . . . . . . . . . . . . . . **V4-T1-68** Standards and Certifications. . . . . . . . . . . . . . . . **V4-T1-68** Product Selection . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-69** Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-75** Technical Data and Specifications. . . . . . . . . . . . **V4-T1-78** Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-85**
**1**
_**Optimum and Efficient Protection for Every Application**_
## **FAZ Circuit Breakers**
## **Product Overview**
Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton’s FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
## _**Powerful offering for machine and system builders**_
The FAZ is available with B, C, D, K, S, and Z characteristics in accordance with UL 1077, CSA C22.2 No.235 and IEC 60947-2. These devices are CE marked.
## **Application Description**
- Supplementary protection
- Control circuits
- Lighting
- Business equipment
- Appliances
## **Features**
- Complete range of UL 1077 recognized DIN rail mounted miniature circuit breakers up to 63A current rating
- Trip-free design—breaker can not be defeated by holding the handle in the ON position
- Captive screws cannot be lost
- Standard ratings of 10 kAIC up to 277/480 Vac
- Fulfill UL 1077, CSA C22.2 No.235 and also IEC 60947-2 Standard
- Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit
- Field-installable shunt trip and auxiliary switch subsequent mounting
- Module width of only 17.7 mm (per pole)
- Suitable for supplementary protection
- Contact position indicator (red/green)
- Thermal-magnetic overcurrent protection
- Easy installation on DIN rail
- Six levels of short-circuit protection, categorized ● Possibility for sealing by B, C, D, K, S, and the toggle in ON or Z curves OFF position
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-67**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## **1** ~~oS~~ **Discover These Advanced Features**
Breakers install on standard DIN rail Available in one-, two-, three-, four-pole, 1+N and 3+N models Color-coded indicator provides breaker status for easy troubleshooting
Captive Posidrive terminal screws with finger and back-ofhand protection (IP20)
Trip-free design; breaker cannot be defeated by holding the handle in the ON position
Breaker information printed on the front of the device for quick identification
## **Standards and Certifications**
- RoHS compliant
FAZ complies with the latest national and international standards.
- VDE compliant
- Devices with B, C, and D curves are VDE compliant
- UL 1077, CSA C22.2 No. 235
- CCC
- Apply to supplementary protectors intended for ● Devices with B, C, use as overcurrent, or and D curves are overvoltage or CCC compliant undervoltage protection ● ABS compliant within an appliance or other electrical . equipment where branch circuit protection is already provided, or is e not required
## **Catalog Number Selection**
|||||||||**FAZ**<br>**C**<br>**6**|**FAZ**<br>**C**<br>**6**|**6**<br>**/**|**6**<br>**/**|**/ 1**|**1**<br>**SP**|**1**<br>**SP**|**SP**|**SP**|**SP**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||||||
|**Breaker Family**<br>**FAZ**= Supplementary<br>protector|||**Trip**<br>**Characteristics**1<br>**B**= 3–5X In<br>**C**= 5–10X In|||**0.5**=<br>**1**||**Ampere Rating**<br>= 0.5A<br>= 1A<br>**13**= 13A<br>**15**= 15A||||||||**1**= Single-pole<br>**2**= Two-pole|= Single-pole<br>= Two-pole|
||||**D**= 10–20X In<br>**K**= 8–12X In<br>**S**= 13–17X In<br>**Z**= 2–3X In|||**2**<br>**3**<br>**4**<br>**5**<br>**6**||= 2A<br>= 3A<br>= 4A<br>= 5A<br>= 6A<br>**16**= 16A<br>**20**= 20A<br>**25**= 25A<br>**30**= 30A<br>**32**= 32A||||||||**3**= Three-pole|= Three-pole|
|||||||**7**<br>**8**||= 7A<br>= 8A<br>**40**= 40A<br>**50**= 50A||||||||||
|||||||**10**||= 10A<br>**63**= 63A||||||||||
**==> picture [223 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single Package<br>SP = Single packaging of single-<br>Number of Poles pole curve B, C and D for<br>1 = Single-pole 4 = Single-pole select amperes only<br>2 = Two-pole 1N = Single-pole + Blank = Standard packaging<br>3 = Three-pole neutral<br>3N = Three-pole +<br>neutral<br>**----- End of picture text -----**<br>
## _**Note**_
> 1 In = Rated current for instantaneous trip characteristics.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-68**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## **Product Selection**
## _**FAZ B curve (3–5X In current rating)**_
- Designed for resistive or slightly inductive loads
- Response time of instantaneous trip: 3–5X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
- UL file number 177451
Suitable for applications where protection against low-level short-circuit faults in control wiring is desired. Instantaneous trip is 3–5X continuous rating of device (In). Applications include PLC wiring, business equipment, lighting, appliances and some motors. Low magnetic trip point.
**Single-Pole B Curve (3–5X In Current Rating)— Designed for Resistive or Slightly Inductive Loads**[1]
**==> picture [196 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 [pq<br>3600 Specified non-tripping 2.55 IN:<br>1200 a current INT = 1.13 x IN for t > 1 h ° t = 1–120 s (It = 1–60 s (IN N < 32A) > 32A)<br>600300 van0 Specified tripping currentIT = 1.45 x IN for t < 1 h 2)9 Type B: 3 x IType B: 5 x INN: t > 0.1 s: t < 0.1 s<br>120 v<br>60 1<br>ToTT<br>30<br>Sn<br>10<br>7 See<br>5<br>7<br>2 e/a<br>1 ee 1<br>0.5 ae<br>ee<br>0.2<br>0.1 ett 3<br>0.05 2 B<br>Onne<br>0.02<br>0.01 Z Gao ea<br>0.005<br>0.002<br>0.001<br>0.0005 eeeee ellieLM yyy2”<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
**Four-Pole B Curve (3–5X In Current Rating)— Designed for Resistive or Slightly Inductive Loads, continued**[1]
**1**
|||**Inductive Loads**|**Inductive Loads**[1]|||||**Inductive Loads, continued**|**Inductive Loads, continued**|**Inductive Loads, continued**[1]||
|---|---|---|---|---|---|---|---|---|---|---|---|
||||**Single-Pole**2|**Two-Pole**|**Three-Pole**|||||**Single-Pole**|**Three-Pole**|
||||**Catalog**|**Catalog**|**Catalog**||||**Four-Pole**|**+ Neutral**|**+ Neutral**|
|||**Amperes**<br>1|**Number**<br>**FAZ-B1/1-SP**|**Number**<br>**FAZ-B1/2**|**Number**<br>**FAZ-B1/3**|||**Amperes**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|
|**Two-Pole**||2<br>3<br>4|**FAZ-B2/1-SP**<br>**FAZ-B3/1-SP**<br>**FAZ-B4/1-SP**|**FAZ-B2/2**<br>**FAZ-B3/2**<br>**FAZ-B4/2**|**FAZ-B2/3**<br>**FAZ-B3/3**<br>**FAZ-B4/3**|**Single-Pole + Neutral**||1<br>2<br>3|**FAZ-B1/4**<br>**FAZ-B2/4**<br>**FAZ-B3/4**|**FAZ-B1/1N**<br>**FAZ-B2/1N**<br>**FAZ-B3/1N**|**FAZ-B1/3N**<br>**FAZ-B2/3N**<br>**FAZ-B3/3N**|
|Ty<br>ae|lef|5<br>6<br>7<br>8|**FAZ-B5/1-SP**<br>**FAZ-B6/1-SP**<br>**FAZ-B7/1-SP**<br>**FAZ-B8/1-SP**|**FAZ-B5/2**<br>**FAZ-B6/2**<br>**FAZ-B7/2**<br>**FAZ-B8/2**|**FAZ-B5/3**<br>**FAZ-B6/3**<br>**FAZ-B7/3**<br>**FAZ-B8/3**|me|ifqr|4<br>**FAZ-B4/4**<br>**FAZ-B4/1N**<br>**FAZ-B4/3N**<br>5<br>**FAZ-B5/4**<br>**FAZ-B5/1N**<br>**FAZ-B5/3N**<br>6<br>**FAZ-B6/4**<br>**FAZ-B6/1N**<br>**FAZ-B6/3N**<br>7<br>**FAZ-B7/4**<br>**FAZ-B7/1N**<br>**FAZ-B7/3N**<br> ~~TI~~||||
|||10|**FAZ-B10/1-SP**|**FAZ-B10/2**|**FAZ-B10/3**|||8|**FAZ-B8/4**|**FAZ-B8/1N**|**FAZ-B8/3N**|
|**Three-Pole**||12<br>13|**FAZ-B12/1-SP**<br>**FAZ-B13/1-SP**|**FAZ-B12/2**<br>**FAZ-B13/2**|**FAZ-B12/3**<br>**FAZ-B13/3**|**Three-Pole + Neutral**||10<br>12|**FAZ-B10/4**<br>**FAZ-B12/4**|**FAZ-B10/1N**<br>**FAZ-B12/1N**|**FAZ-B10/3N**<br>**FAZ-B12/3N**|
|||15<br>16|**FAZ-B15/1-SP**<br>**FAZ-B16/1-SP**|**FAZ-B15/2**<br>**FAZ-B16/2**|**FAZ-B15/3**<br>**FAZ-B16/3**|||13<br>15|**FAZ-B13/4**<br>**FAZ-B15/4**|**FAZ-B13/1N**<br>**FAZ-B15/1N**|**FAZ-B13/3N**<br>**FAZ-B15/3N**|
|||20|**FAZ-B20/1-SP**|**FAZ-B20/2**|**FAZ-B20/3**|||16|**FAZ-B16/4**|**FAZ-B16/1N**|**FAZ-B16/3N**|
|||||||||||||
|||25|**FAZ-B25/1-SP**|**FAZ-B25/2**|**FAZ-B25/3**|||20|**FAZ-B20/4**|**FAZ-B20/1N**|**FAZ-B20/3N**|
|||||||||||||
|||30|**FAZ-B30/1-SP**|**FAZ-B30/2**|**FAZ-B30/3**|||25|**FAZ-B25/4**|**FAZ-B25/1N**|**FAZ-B25/3N**|
|||32<br>40|**FAZ-B32/1-SP**<br>**FAZ-B40/1-SP**|**FAZ-B32/2**<br>**FAZ-B40/2**|**FAZ-B32/3**<br>**FAZ-B40/3**|||30<br>32|**FAZ-B30/4**<br>**FAZ-B32/4**|**FAZ-B30/1N**<br>**FAZ-B32/1N**|**FAZ-B30/3N**<br>**FAZ-B32/3N**|
|||||||||||||
|||50<br>63|**FAZ-B50/1-SP**<br>**FAZ-B63/1-SP**|**FAZ-B50/2**<br>**FAZ-B63/2**|**FAZ-B50/3**<br>**FAZ-B63/3**|||40<br>50|**FAZ-B40/4**<br>**FAZ-B50/4**|**FAZ-B40/1N**<br>**FAZ-B50/1N**|**FAZ-B40/3N**<br>**FAZ-B50/3N**|
|||||||||||||
|||||||||63|**FAZ-B63/4**|**FAZ-B63/1N**|**FAZ-B63/3N**|
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-69**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## _**FAZ C curve (5–10X In current rating)**_
- Designed for inductive loads
- Response time of instantaneous trip: 5–10X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
- UL file number 177451
Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 5–10X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point.
**==> picture [195 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200<br>12003600 vonY Specified non-tripping currentINT = 1.13 x IN for t > 1 h Type C: 5 x IType C: 10 x INN: t > 0.1 s: t < 0.1 s<br>600 LA Specified tripping current<br>300 IT = 1.45 x IN for t < 1 h<br>120<br>FO<br>60<br>7eee<br>30<br>a ee<br>10<br>5<br>2 e K o<br>1<br>777 |<br>0.5<br>pf<br>0.2<br>0.1 7) 2 eee<br>0.05 1 l C y<br>0.02<br>yg<br>0.01<br>0.005<br>0.002<br>0.001 a ee<br>0.0005 ee<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
|**Single-Pole**|**Single-Pole**||**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads**1|**Four-Pole**|**Four-Pole**|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads, continued**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads, continued**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads, continued**1|**C Curve (5–10X In Current Rating)—**<br>**Designed Inductive Loads, continued**1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||**Single-Pole**2|**Two-Pole**|**Three-Pole**|||||**Single-Pole**|**Three-Pole**|
|||||**Catalog**|**Catalog**|**Catalog**||||**Four-Pole**|**+ Neutral**|**+ Neutral**|
||||**Amperes**|**Number**|**Number**|**Number**||||**Catalog**|**Catalog**|**Catalog**|
||||0.5|**FAZ-C0.5/1-SP**|**FAZ-C0.5/2**|**FAZ-C0.5/3**|||**Amperes**|**Number**|**Number**|**Number**|
|**Two-Pole**|||1<br>1.6<br>2<br>3|**FAZ-C1/1-SP**<br>**FAZ-C1.6/1-SP**<br>**FAZ-C2/1-SP**<br>**FAZ-C3/1-SP**|**FAZ-C1/2**<br>**FAZ-C1.6/2**<br>**FAZ-C2/2**<br>**FAZ-C3/2**|**FAZ-C1/3**<br>**FAZ-C1.6/3**<br>**FAZ-C2/3**<br>**FAZ-C3/3**|**Single-Pole + Neutral**||0.5<br>1<br>1.6<br>2|**FAZ-C0.5/4**<br>**FAZ-C1/4**<br>**FAZ-C1.6/4**<br>**FAZ-C2/4**|**FAZ-C0.5/1N**<br>**FAZ-C1/1N**<br>**FAZ-C1.6/1N**<br>**FAZ-C2/1N**|**FAZ-C0.5/3N**<br>**FAZ-C1/3N**<br>**FAZ-C1.6/3N**<br>**FAZ-C2/3N**|
|can|w|+|4<br>5|**FAZ-C4/1-SP**<br>**FAZ-C5/1-SP**|**FAZ-C4/2**<br>**FAZ-C5/2**|**FAZ-C4/3**<br>**FAZ-C5/3**|ram|wR|3<br>4|**FAZ-C3/4**<br>**FAZ-C4/4**|**FAZ-C3/1N**<br>**FAZ-C4/1N**|**FAZ-C3/3N**<br>**FAZ-C4/3N**<br>~~ee~~|
|**Three-Pole**|||6<br>7<br>8<br>10<br>13|**FAZ-C6/1-SP**<br>**FAZ-C7/1-SP**<br>**FAZ-C8/1-SP**<br>**FAZ-C10/1-SP**<br>**FAZ-C13/1-SP**|**FAZ-C6/2**<br>**FAZ-C7/2**<br>**FAZ-C8/2**<br>**FAZ-C10/2**<br>**FAZ-C13/2**|**FAZ-C6/3**<br>**FAZ-C7/3**<br>**FAZ-C8/3**<br>**FAZ-C10/3**<br>**FAZ-C13/3**|**Three-Pole + Neutral**||5<br>6<br>7<br>8<br>10|**FAZ-C5/4**<br>**FAZ-C6/4**<br>**FAZ-C7/4**<br>**FAZ-C8/4**<br>**FAZ-C10/4**|**FAZ-C5/1N**<br>**FAZ-C6/1N**<br>**FAZ-C7/1N**<br>**FAZ-C8/1N**<br>**FAZ-C10/1N**|**FAZ-C5/3N**<br>**FAZ-C6/3N**<br>**FAZ-C7/3N**<br>**FAZ-C8/3N**<br>**FAZ-C10/3N**|
||||15<br>16<br>20<br>25<br>30<br>32<br>40|**FAZ-C15/1-SP**<br>**FAZ-C16/1-SP**<br>**FAZ-C20/1-SP**<br>**FAZ-C25/1-SP**<br>**FAZ-C30/1-SP**<br>**FAZ-C32/1-SP**<br>**FAZ-C40/1-SP**|**FAZ-C15/2**<br>**FAZ-C16/2**<br>**FAZ-C20/2**<br>**FAZ-C25/2**<br>**FAZ-C30/2**<br>**FAZ-C32/2**<br>**FAZ-C40/2**|**FAZ-C15/3**<br>**FAZ-C16/3**<br>**FAZ-C20/3**<br>**FAZ-C25/3**<br>**FAZ-C30/3**<br>**FAZ-C32/3**<br>**FAZ-C40/3**|||13<br>15<br>16<br>20<br>25<br>32<br>40|**FAZ-C13/4**<br>**FAZ-C15/4**<br>**FAZ-C16/4**<br>**FAZ-C20/4**<br>**FAZ-C25/4**<br>**FAZ-C32/4**<br>**FAZ-C40/4**|**FAZ-C13/1N**<br>**FAZ-C15/1N**<br>**FAZ-C16/1N**<br>**FAZ-C20/1N**<br>**FAZ-C25/1N**<br>**FAZ-C32/1N**<br>**FAZ-C40/1N**|**FAZ-C13/3N**<br>**FAZ-C15/3N**<br>**FAZ-C16/3N**<br>**FAZ-C20/3N**<br>**FAZ-C25/3N**<br>**FAZ-C32/3N**<br>**FAZ-C40/3N**|
||||50<br>63|**FAZ-C50/1-SP**<br>**FAZ-C63/1-SP**|**FAZ-C50/2**<br>**FAZ-C63/2**|**FAZ-C50/3**<br>**FAZ-C63/3**|||50<br>63|**FAZ-C50/4**<br>**FAZ-C63/4**|**FAZ-C50/1N**<br>**FAZ-C63/1N**|**FAZ-C50/3N**<br>**FAZ-C63/3N**|
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
- 2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-70**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## _**FAZ D curve (10–20X In current rating)**_
**==> picture [196 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 Zo<br>3600 v= Specified non-tripping current ® 2.55 It = 1–60 s (IN: N < 32A)<br>1200 INT = 1.13 x IN for t > 1 h t = 1–120 s (IN > 32A)<br>600300 Z Specified tripping currentIT = 1.45 x IN for t < 1 h Type D: 10 x IType D: 20 x INN: t > 0.1 s: t < 0.1 s<br>120<br>60 LT Mo 1 [iit |) ft to<br>30<br>HI ttf<br>10 ReoTeel<br>5<br>2<br>1<br>1<br>0.5<br>0.2<br>0.1 3<br>0.05 -—aA 2 D HH<br>ee 77<br>0.02<br>0.01<br>Pepe |<br>0.005<br>0.002<br>0.001<br>0.0005 ee eee<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>1.13 1.45<br>t [sec]<br>**----- End of picture text -----**<br>
- Designed for highly inductive loads
- Response time of instantaneous trip: 10–20X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
- UL file number 177451
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 10–20X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
**D Curve (10–20X In Current Rating)— Designed for Inductive Loads, continued**[1]
|||||||||||**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**|**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**|**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**|**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Single-Pole**|||**D Curve (10–20X In Current Rating)—**<br>**Designed for Inductive Loads**1||||**Four-Pole**|||**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**<br>**Designed for Inductive Loads, continued**|||**D Curve (10–20X In Current Rating)—n Current Rating)— Current Rating)—**<br>**Designed for Inductive Loads, continued**[1]|
|||||**Single-Pole**2|**Two-Pole**|**Three-Pole**||||||**Single-Pole**|**Three-Pole**|
|||||**Catalog**|**Catalog**|**Catalog**|||||**Four-Pole**|**+ Neutral**|**+ Neutral**|
||||**Amperes**|**Number**|**Number**|**Number**|||||**Catalog**|**Catalog**|**Catalog**|
||||0.5|**FAZ-D0.5/1-SP**|**FAZ-D0.5/2**|**FAZ-D0.5/3**||||**Amperes**|**Number**|**Number**|**Number**|
||||1<br>2|**FAZ-D1/1-SP**<br>**FAZ-D2/1-SP**|**FAZ-D1/2**<br>**FAZ-D2/2**|**FAZ-D1/3**<br>**FAZ-D2/3**||||0.5<br>1|**FAZ-D0.5/4**<br>**FAZ-D1/4**|**FAZ-D0.5/1N**<br>**FAZ-D1/1N**|**FAZ-D0.5/3N**<br>**FAZ-D1/3N**|
|**Two-Pole**<br>or<br>w||5|3<br>4<br>5<br>6|**FAZ-D3/1-SP**<br>**FAZ-D4/1-SP**<br>**FAZ-D5/1-SP**<br>**FAZ-D6/1-SP**|**FAZ-D3/2**<br>**FAZ-D4/2**<br>**FAZ-D5/2**<br>**FAZ-D6/2**|**FAZ-D3/3**<br>**FAZ-D4/3**<br>**FAZ-D5/3**<br>**FAZ-D6/3**|**Single-Pole + Neutral**<br>iim<br>w Bt|||2<br>3<br>4<br>5|**FAZ-D2/4**<br>**FAZ-D3/4**<br>**FAZ-D4/4**<br>**FAZ-D5/4**|**FAZ-D2/1N**<br>**FAZ-D3/1N**<br>**FAZ-D4/1N**<br>**FAZ-D5/1N**|**FAZ-D2/3N**<br>**FAZ-D3/3N**<br>**FAZ-D4/3N**<br>**FAZ-D5/3N**|
||||7|**FAZ-D7/1-SP**|**FAZ-D7/2**|**FAZ-D7/3**||||6|**FAZ-D6/4**|**FAZ-D6/1N**|**FAZ-D6/3N**|
|**Three-Pole**|||8<br>10<br>13<br>15|**FAZ-D8/1-SP**<br>**FAZ-D10/1-SP**<br>**FAZ-D13/1-SP**<br>**FAZ-D15/1-SP**|**FAZ-D8/2**<br>**FAZ-D10/2**<br>**FAZ-D13/2**<br>**FAZ-D15/2**|**FAZ-D8/3**<br>**FAZ-D10/3**<br>**FAZ-D13/3**<br>**FAZ-D15/3**|**Three-Pole + Neutral**|||7<br>8<br>10<br>13|**FAZ-D7/4**<br>**FAZ-D8/4**<br>**FAZ-D10/4**<br>**FAZ-D13/4**|**FAZ-D7/1N**<br>**FAZ-D8/1N**<br>**FAZ-D10/1N**<br>**FAZ-D13/1N**|**FAZ-D7/3N**<br>**FAZ-D8/3N**<br>**FAZ-D10/3N**<br>**FAZ-D13/3N**|
|@e|16<br>**FAZ-D16/1-SP**<br>20<br>**FAZ-D20/1-SP**<br>25<br>**FAZ-D25/1-SP**<br>30<br>**FAZ-D30/1-SP**<br>32<br>**FAZ-D32/1-SP**<br>een~~oo~~||||**FAZ-D16/2**<br>**FAZ-D20/2**<br>**FAZ-D25/2**<br>**FAZ-D30/2**<br>**FAZ-D32/2**|**FAZ-D16/3**<br>**FAZ-D20/3**<br>**FAZ-D25/3**<br>**FAZ-D30/3**<br>**FAZ-D32/3**<br>~~oo~~|@|oe°|15<br>**FAZ-D15/4**<br>**FAZ-D15/1N**<br>**FAZ-D15/3N**<br>16<br>**FAZ-D16/4**<br>**FAZ-D16/1N**<br>**FAZ-D16/3N**<br>20<br>**FAZ-D20/4**<br>**FAZ-D20/1N**<br>**FAZ-D20/3N**<br>25<br>**FAZ-D25/4**<br>**FAZ-D25/1N**<br>**FAZ-D25/3N**<br>30<br>**FAZ-D30/4**<br>**FAZ-D30/1N**<br>**FAZ-D30/3N**<br>‘~~ee~~|||||
||||40<br>503|**FAZ-D40/1-SP**<br>**FAZ-D50/1-SP**|**FAZ-D40/2**<br>**FAZ-D50/2**|**FAZ-D40/3**<br>**FAZ-D50/3**||||32<br>40|**FAZ-D32/4**<br>**FAZ-D40/4**|**FAZ-D32/1N**<br>**FAZ-D40/1N**|**FAZ-D32/3N**<br>**FAZ-D40/3N**|
||||633|**FAZ-D63/1-SP**|**FAZ-D63/2**|**FAZ-D63/3**||||50c<br>63c|**FAZ-D50/4**<br>**FAZ-D63/4**|**FAZ-D50/1N**<br>**FAZ-D63/1N**|**FAZ-D50/3N**<br>**FAZ-D63/3N**|
**1**
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
- 2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering.
- 3 IEC 60947-2 only.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-71**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## **1** _**FAZ K curve (8–12X I**_ ● Designed for motors, transformers and upstream electronics _**n current rating)**_ ~~oo~~
- Response time of instantaneous trip: 8–12X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
- UL file number 177451
Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 8–12X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point.
**==> picture [208 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 Sp a Specified<br>3600 non-tripping current<br>1200600300 mn I\\ I\\ tT tf for t > 1 hSpecified tripping current I nt = 1.05 u I n<br>120 P\\ tt ety I t = 1.30 u I n<br>60 ae for t < 1 h<br>30<br>| \ \AAAHHAHP<br>10 PN<br>5 aNNeee<br>PN NG<br>2<br>1 a NNeee<br>0.5 a K eee<br>0.2 ee ee ee ee<br>0.1 Po CE<br>0.05 ae ee eee<br>0.02 ee ee ee ee<br>0.01 eee eee<br>0.005 | TT TT TY —<br>0.002 Pt QE<br>0.001 Po=<br>0.0005 PTE<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>U-rated Current<br>1.13 1.45<br> (sec) t<br>**----- End of picture text -----**<br>
**K Curve (8–12X In Current Rating)— Designed for Inductive Loads, continued**[12]
|**Single-Pole**|**Single-Pole**|**K Curve (8–12X In Current Rating)—**<br>**Designed for Inductive Loads**12|**Four-Pole**|||**K Curve (8–12X In Current Rating)—n Current Rating)— Current Rating)—**<br>**Designed for Inductive Loads, continued**|**K Curve (8–12X In Current Rating)—n Current Rating)— Current Rating)—**<br>**Designed for Inductive Loads, continued**|**K Curve (8–12X In Current Rating)—n Current Rating)— Current Rating)—**<br>**Designed for Inductive Loads, continued **[12]|
|---|---|---|---|---|---|---|---|---|
|rim if<br>®3|'|**Single-Pole**3<br>**Two-Pole**<br>**Three-Pole**<br>**Amperes**<br>**Catalog**<br>**Number**<br>**Catalog**<br>**Number**<br>**Catalog**<br>**Number**<br>0.5<br>**FAZ-K0.5/1**<br>**FAZ-K0.5/2**<br>**FAZ-K0.5/3**<br>1<br>**FAZ-K1/1**<br>**FAZ-K1/2**<br>**FAZ-K1/3**<br>~~co rOrereeeeeeeeerrrerererereeseee—~~|=<br>2 ai) . s|7<br> SM|‘|**Four-Pole**3<br>**Amperes**<br>**Catalog**<br>**Number**<br>0.5<br>**FAZ-K0.5/4**<br>1<br>**FAZ-K1/4**|**Single-Pole**<br>**+ Neutral**<br>**Catalog**<br>**Number**<br>**FAZ-K0.5/1N**<br>**FAZ-K1/1N**|**Three-Pole**<br>**+ Neutral**<br>**Catalog**<br>**Number**<br>**FAZ-K0.5/3N**<br>**FAZ-K1/3N**|
|**Two-Pole**||1.6<br>**FAZ-K1.6/1**<br>**FAZ-K1.6/2**<br>**FAZ-K1.6/3**<br>2<br>**FAZ-K2/1**<br>**FAZ-K2/2**<br>**FAZ-K2/3**|**Single-Pole + Neutral**|||1.6<br>**FAZ-K1.6/4**<br>2<br>**FAZ-K2/4**|**FAZ-K1.6/1N**<br>**FAZ-K2/1N**|**FAZ-K1.6/3N**<br>**FAZ-K2/3N**|
|**Three-Pole**||3<br>**FAZ-K3/1**<br>**FAZ-K3/2**<br>**FAZ-K3/3**<br>4<br>**FAZ-K4/1**<br>**FAZ-K4/2**<br>**FAZ-K4/3**<br>6<br>**FAZ-K6/1**<br>**FAZ-K6/2**<br>**FAZ-K6/3**<br>8<br>**FAZ-K8/1**<br>**FAZ-K8/2**<br>**FAZ-K8/3**<br>10<br>**FAZ-K10/1**<br>**FAZ-K10/2**<br>**FAZ-K10/3**<br>13<br>**FAZ-K13/1**<br>**FAZ-K13/2**<br>**FAZ-K13/3**<br>16<br>**FAZ-K16/1**<br>**FAZ-K16/2**<br>**FAZ-K16/3**<br>20<br>**FAZ-K20/1**<br>**FAZ-K20/2**<br>**FAZ-K20/3**<br>25<br>**FAZ-K25/1**<br>**FAZ-K25/2**<br>**FAZ-K25/3**<br>32<br>**FAZ-K32/1**<br>**FAZ-K32/2**<br>**FAZ-K32/3**<br>40<br>**FAZ-K40/1**<br>**FAZ-K40/2**<br>**FAZ-K40/3**<br>50<br>**FAZ-K50/1**<br>**FAZ-K50/2**<br>**FAZ-K50/3**|**Three-Pole + Neutral**|||3<br>**FAZ-K3/4**<br>4<br>**FAZ-K4/4**<br>6<br>**FAZ-K6/4**<br>8<br>**FAZ-K8/4**<br>10<br>**FAZ-K10/4**<br>13<br>**FAZ-K13/4**<br>16<br>**FAZ-K16/4**<br>20<br>**FAZ-K20/4**<br>25<br>**FAZ-K25/4**<br>32<br>**FAZ-K32/4**<br>40<br>**FAZ-K40/4**<br>50<br>**FAZ-K50/4**|**FAZ-K3/1N**<br>**FAZ-K4/1N**<br>**FAZ-K6/1N**<br>**FAZ-K8/1N**<br>**FAZ-K10/1N**<br>**FAZ-K13/1N**<br>**FAZ-K16/1N**<br>**FAZ-K20/1N**<br>**FAZ-K25/1N**<br>**FAZ-K32/1N**<br>**FAZ-K40/1N**<br>**FAZ-K50/1N**|**FAZ-K3/3N**<br>**FAZ-K4/3N**<br>**FAZ-K6/3N**<br>**FAZ-K8/3N**<br>**FAZ-K10/3N**<br>**FAZ-K13/3N**<br>**FAZ-K16/3N**<br>**FAZ-K20/3N**<br>**FAZ-K25/3N**<br>**FAZ-K32/3N**<br>**FAZ-K40/3N**<br>**FAZ-K50/3N**|
|||63<br>**FAZ-K63/1**<br>**FAZ-K63/2**<br>**FAZ-K63/3**||||63<br>**FAZ-K63/4**|**FAZ-K63/1N**|**FAZ-K63/3N**|
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
- 2 These breakers are available by special order and may result in additional delivery time.
- 3 Two-piece box order, quantities of 2.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-72**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## _**FAZ S curve (13–17X In current rating)**_
- Designed for control circuits with high inrush
- Response time of instantaneous trip: 13–17X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
- UL file number 177451
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
**==> picture [208 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 Specified<br>3600 non-tripping current<br>1200 | ttVf TT for t > 1 h I nt = 1.05 u I n<br>600 Specified<br>300 \ \a tT Tt tit tripping current<br>120 P\\ LL I t = 1.30 u I n<br>for t < 1 h<br>60 | \ Xt TET<br>30 ee eee<br>105 PNTaPoNNNNNeeeEE ETeee<br>2 a<br>1<br>0.5 Po Ne S eeeee<br>0.2 [eee]<br>ee [ee] EA NN<br>0.1 a ee eee<br>0.05 | TT ETTTTT | EE<br>0.02<br>pt EE EEE<br>0.01 pT<br>0.005 a dT ECE TTTTT P |} Met<br>0.002<br>P|ee _<br>0.001 | TTETTECE TT PP<br>0.0005 es<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>U-rated Current<br>1.05 1.30<br> (sec) t<br>**----- End of picture text -----**<br>
|**Single-Pole**|**Single-Pole**|**Single-Pole**|**S Curve (13–17X In Current Rating)—**<br>**Designed for Inductive Loads**12|**S Curve (13–17X In Current Rating)—**<br>**Designed for Inductive Loads**12|**S Curve (13–17X In Current Rating)—**<br>**Designed for Inductive Loads**12|
|---|---|---|---|---|---|
|7.<br>en"1|||"<br> P|**Amperes**|**Single-Pole**3<br>**Catalog**<br>**Number**|**Two-Pole**<br>**Catalog**<br>**Number**|
||||1|**FAZ-S1/1**|**FAZ-S1/2**|
||||2|**FAZ-S2/1**|**FAZ-S2/2**|
||||3|**FAZ-S3/1**|**FAZ-S3/2**|
|**Two-Pole**|||4|**FAZ-S4/1**|**FAZ-S4/2**|
||||6|**FAZ-S6/1**|**FAZ-S6/2**|
|ag||E||10<br>16<br>20|**FAZ-S10/1**<br>**FAZ-S16/1**<br>**FAZ-S20/1**|**FAZ-S10/2**<br>**FAZ-S16/2**<br>**FAZ-S20/2**|
||||25|**FAZ-S25/1**|**FAZ-S25/2**|
||||32|**FAZ-S32/1**|**FAZ-S32/2**|
||||40|**FAZ-S40/1**|**FAZ-S40/2**|
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
- 2 These breakers are available by special order and may result in additional delivery time.
- 3 Two-piece box order, quantities of 2.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-73**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## _**FAZ Z curve (2–3X In current rating)**_
**==> picture [207 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
72003600 1 n s Specified non-tripping current<br>1200600 ll VY I for t > 1 hSpecified nt = 1.05 u I n<br>300 P\\ Ey ye tripping current<br>120 P\\E | I t = 1.30 u I n<br>60 a for t < 1 h<br>3010 YTPo\\ NNTETTTT TTT<br>5 eeee eeeeTE<br>2 ee ee<br>0.51 ee<br>0.2 a Z ee<br>0.1 ee ee<br>0.05 ee ee<br>0.02 a ee<br>0.01 | ee<br>0.005 PIN a ——<br>0.002 PF |rr<br>0.001 rr eeee<br>0.0005 PTT TT<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>U-rated Current<br>1.05 1.30<br> (sec) t<br>**----- End of picture text -----**<br>
- Designed for protection of electronic devices
- Response time of instantaneous trip: 2–3X In current rating
- UL recognized and CSA Certified as supplementary protectors
- For international and domestic use (conform to IEC 60947-2)
Suitable for applications where low levels of inrush current are expected. Instantaneous trip is 2–3X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point.
**Single-Pole Z Curve (2–3X In Current Rating)— Designed for Inductive Loads**[12]
|**Single-Pole**|**Z Curve (2–3X In Current Rating)—**|**Z Curve (2–3X In Current Rating)—n Current Rating)— Current Rating)—**|**Z Curve (2–3X In Current Rating)—n Current Rating)— Current Rating)—**||
|---|---|---|---|---|
|**Single-Pole**|**Z Curve (2–3X In Current Rating)—**<br>**Designed for Inductive Loads**|**Z Curve (2–3X In Current Rating)—n Current Rating)—**<br>**Designed for Inductive Loads**[12]<br>**Single-Pole**3<br>**Two-Pole**||**Z Curve (2–3X In Current Rating)—**<br>**Designed for Inductive Loads, continued **12<br>**Three-Pole**|
||**Amperes**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|**Three-Pole**<br>**Four-Pole**<br>**Catalog**<br>**Catalog**|
|**Two-Pole**<br>e|0.5<br>1<br>1.6<br>2<br>3|**FAZ-Z0.5/1**<br>**FAZ-Z1/1**<br>**FAZ-Z1.6/1**<br>**FAZ-Z2/1**<br>**FAZ-Z3/1**|**FAZ-Z0.5/2**<br>**FAZ-Z1/2**<br>**FAZ-Z1.6/2**<br>**FAZ-Z2/2**<br>**FAZ-Z3/2**|**Amperes**<br>**Number**<br>**Number**<br>0.5<br>**FAZ-Z0.5/3**<br>**FAZ-Z0.5/4**<br>1<br>**FAZ-Z1/3**<br>**FAZ-Z1/4**<br>1.6<br>**FAZ-Z1.6/3**<br>**FAZ-Z1.6/4**<br>2<br>**FAZ-Z2/3**<br>**FAZ-Z2/4**<br>**Four-Pole**<br>“weBy ~~pe~~|
||4<br>6<br>8<br>10<br>13<br>16|**FAZ-Z4/1**<br>**FAZ-Z6/1**<br>**FAZ-Z8/1**<br>**FAZ-Z10/1**<br>**FAZ-Z13/1**<br>**FAZ-Z16/1**|**FAZ-Z4/2**<br>**FAZ-Z6/2**<br>**FAZ-Z8/2**<br>**FAZ-Z10/2**<br>**FAZ-Z13/2**<br>**FAZ-Z16/2**|3<br>**FAZ-Z3/3**<br>**FAZ-Z3/4**<br>4<br>**FAZ-Z4/3**<br>**FAZ-Z4/4**<br>6<br>**FAZ-Z6/3**<br>**FAZ-Z6/4**<br>8<br>**FAZ-Z8/3**<br>**FAZ-Z8/4**<br>10<br>**FAZ-Z10/3**<br>**FAZ-Z10/4**<br>13<br>**FAZ-Z13/3**<br>**FAZ-Z13/4**|
||20<br>25<br>32<br>40<br>50|**FAZ-Z20/1**<br>**FAZ-Z25/1**<br>**FAZ-Z32/1**<br>**FAZ-Z40/1**<br>**FAZ-Z50/1**|**FAZ-Z20/2**<br>**FAZ-Z25/2**<br>**FAZ-Z32/2**<br>**FAZ-Z40/2**<br>**FAZ-Z50/2**|16<br>**FAZ-Z16/3**<br>**FAZ-Z16/4**<br>20<br>**FAZ-Z20/3**<br>**FAZ-Z20/4**<br>25<br>**FAZ-Z25/3**<br>**FAZ-Z25/4**<br>32<br>**FAZ-Z32/3**<br>**FAZ-Z32/4**<br>40<br>**FAZ-Z40/3**<br>**FAZ-Z40/4**|
||63|**FAZ-Z63/1**|**FAZ-Z63/2**|50<br>**FAZ-Z50/3**<br>**FAZ-Z50/4**<br>63<br>**FAZ-Z63/3**<br>**FAZ-Z63/4**|
## _**Notes**_
- 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
- 2 These breakers are available by special order and may result in additional delivery time.
- 3 Two-piece box order, quantities of 2.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-74**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
## **Accessories**
**1**
**FAZ Auxiliary Contacts and Voltage Trips**
**==> picture [503 x 469] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Rated Operational|Catalog|
|Circuit Diagram|Description|Voltage|Number|
|Standard Auxiliary Contacts|
|■|1NO/1NC|230 Vac|FAZ-XHIN11|
|■|Installs on left side of FAZ or shunt trip|
|■|Max. one per FAZ (1077) device|
|■|Switches when FAZ is tripped|
|electrically or manually|
|to!|12|14|■■|1 changeover contactInstalls on left side of FAZ or shunt trip|230 Vac|FAZ-XHINW1|
|■|Max. one per FAZ (1077) device|
|■|Switches when FAZ is tripped|
|electrically or manually|
|,|
|11|
|Auxiliary/Trip Indicating Contact|
|■|Small selector screw changes mode|230 Vac|FAZ-XAM002|
|■|Two Form C (changeover) contacts|
|■|Installs on left side of FAZ or shunt trip|
|■|Auxiliary contacts switch when FAZ is|
|11|95|tripped electrically or manually|
|\|■|Trip indicating contact switches only|
|when FAZ is tripped electrically|
|Two-pole auxiliary mode|
|Trip indicating mode|
|Undervoltage Trip|
|■|Prevents FAZ from operating unless|115 Vac|FAZ-XUA(115VAC)|
|D1|voltage is present|
|230 Vac|FAZ-XUA(230VAC)|
|2|U|■|Installs on left side of FAZ|
|■|Includes test button|400 Vac|FAZ-XUA(400VAC)|
|D2|
|Shunt Trip|
|■|Allows remote trip of FAZ|12–110 Vac|FAZ-XAA-C-12-110VAC|
|C1|■|Installs on left side of FAZ|12–60 Vdc|
|110–415 Vac|FAZ-XAA-C-110-|
|C2|110–230 Vdc|415VAC|
**----- End of picture text -----**<br>
**Allowable Combinations of Accessories**
**==> picture [324 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
a) el SI al & |2) [2 2] [2<br>AUX AUX FAZ AUX AUX FAZ FAZ<br>TRIP TRIP<br>or or<br>Circuit Shunt Circuit UnderV Circuit<br>Breaker Trip Breaker Trip Breaker<br>iaSA |_|lel |Aa |lel| {|le ot2} |__|[2<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-75**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**Busbar System 1**
||||||**Number of Poles**|**Number of**|**Catalog**|
|---|---|---|---|---|---|---|---|
|**Description**<br>**Without Auxiliary Contacts**|**Without Auxiliary Contacts**|||**Rated Operational Current**|**per Device**|**Terminals**|**Number**1|
|For connecting FAZ supplementary protectors without auxiliary<br>contacts. May be fed from line or load side.||||80A|1|57|**BB-UL-18/1P-1M/57**|
||||||2|56|**BB-UL-18/2P-2M/56**|
|||||||||
||||||3|57|**BB-UL-18/3P-3M/57**|
|FAZ<br>FAZ<br>FAZ||||||||
|||||||||
|~~alele~~||||100A|1<br>2|57<br>56|**BB-UL-25/1P-1M/57**<br>**BB-UL-25/2P-2M/56**|
|||||||||
||||||3|57|**BB-UL-25/3P-3M/57**|
|||||||||
|**Auxiliary/Trip Indicating Contacts**||||||||
|For connecting FAZ supplementary protectors with auxiliary<br>contacts. May be fed from line or load side.||||80A|1|37|**BB-UL-18/1P-1,5M/37**|
||||||2|46|**BB-UL-18/2P+AS-2,5M/46**|
|||||||||
|FAZ<br>FAZ<br>~~isin~~<br>~~nign~~<br>~~Fit~~<br>~~algal~~<br>~~2k~~||||3<br>48<br>**BB-UL-18/3P+AS-3,5M/48**<br>100A<br>1<br>37<br>**BB-UL-25/1P-1,5M/37**<br>2<br>46<br>**BB-UL-25/2P+AS-2,5M/46**<br>~~OB~~<br>~~Be~~||||
|||||||||
||||||3|48|**BB-UL-25/3P+AS-3,5M/48**|
## _**Note**_
> 1 Bus may be center fed for high current capacity.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-76**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**Incoming Terminal Pin Type Incoming Supply Terminals Incoming Terminal Bus Incoming Supply Terminals 1 Catalog Catalog Description Number Description Number 1** ■ Accommodates conductors **BB-UL-TEP/35** ■ 50 mm[2] **BB-UL-TE/50** from 6–35 mm[2] /#10–2 AWG ■ #14–1 AWG ~~2~~ ■ 4–5.5 Nm/35–50 lb-in ~~ee~~ ■ ~~a~~ 75 Deg wire **1** ■ Two- and three-pole ■ 115 A/Y, 480V UL ~~we~~ Sap ~~Bo~~ ■ ~~OS~~ 160 A/Y 690V IEC **1 1 Fork Connector Busbar End Cap Incoming Terminal Pin Type Incoming Supply Terminals— Catalog 1 Single-Phase Only** 74 ~~S~~ **Description** ~~e~~ **Poles Number Catalog** ■ Install after cutting busbar 2 and 3 **BB-EV-EC/3 1 Description Number** ■ Protects end of busbar 1 **BB-UL-EC/1** ■ Accommodates conductors **BB-UL-TEPA/35 1** from 6–35 mm[2] /#10–2 AWG ■ 4–5.5 Nm/35–50 lb-in **1 1 Protective Accessories Catalog 1 Description Number Busbar Terminal Cover** For covering **BB-IP/5 1** unused terminals **1 1** we **1 Lockoff Device** UL lockoff device **FAZPLOFF 1 1 1 1** ~~a)~~ **1 Padlock Hasp** ■ Prevents reactivation of the device **Z-IS/SPE-1TE 1** during maintenance ■ Holds one padlock
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-77**
Miniature Circuit Breakers and Supplementary Protectors
1.3
**1**
UL 1077 DIN Rail Supplementary Protectors
## **Technical Data and Specifications**
## _**Trip Curves Chart**_
Eaton FAZ supplementary protectors are available with six different tripping characteristics, including Type B, C, D, K, S and Z. Definitions for each trip curve are contained on the ordering pages and can be used to determine the optimal characteristic for your application. For example, low-level short-circuit faults in control wiring, such as PLCs, are best protected by devices with Type B trip characteristics (3–5X continuous rating of the device (In).
Even though not required by NEC or CEC for supplementary protectors, Eaton’s FAZ devices are current limiting, which means that they interrupt fault currents within one half cycle. Current limiting devices offer superior protection by reducing peak let-through current and energy.
## **Tripping Characteristics**
**==> picture [240 x 298] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200 Time-current characteristic acc. to UL 1077<br>3600 � Conventional � 2.55 I N :<br>non-tripping current t = 1–60 s (IN < 32A)<br>1200 I nt = 1.13 I N : t > 1 h t = 1–120 s (I N < 32A)<br>600 � Conventional tripping � Type B: 3 I N : t > 0.1 s<br>300120 current It = 1.45 IN: t < 1 h � � Type B: 5 I Type C: 5 IN N: t < 0.1 s : t > 0.1 s<br>60 � Type C: 10 I N : t < 0.1 s<br>30 � Type D: 10 I N : t > 0.1 s<br>� Type D: 20 IN: t < 0.1 s<br>10<br>5<br>2<br>1 D<br>0.5<br>0.2<br>0.1 Z B C K S<br>0.05<br>0.02<br>0.01<br>0.005<br>0.002<br>0.001<br>0.0005<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I/ I n<br>1.05 1.30<br>1.13 1.45<br> (sec) t<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-78**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## **FAZ Miniature Circuit Breakers Technical Data**
|**Description**|**B Curve**|**C Curve**|**D Curve**|
|---|---|---|---|
|**Electrical**||||
|Approvals|UR (UL 1077), CSA (CSA 22.2 No. 235), CE|||
|Standards|IEC/EN 60947-2|||
|Short-circuit trip response|3–5_I_n|5–10_I_n|10–20_I_n|
|**Supplementary Protectors—UL/CSA**||||
|Current range|1–63A|0.5–63A|0.5–40A|
|Maximum voltage ratings—UL/CSA||||
|Single-pole, single-pole + neutral|277 Vac|277 Vac|277 Vac|
||48 Vdc|48 Vdc|48 Vdc|
|Two-, three-pole, four-pole and||||
|three-pole + neutral|480Y/277 Vac|480Y/277 Vac|480Y/277 Vac|
|Two poles in series|96 Vdc|96 Vdc|96 Vdc|
|Thermal tripping characteristics||||
|Single-pole|1.35 x In@ 40°C|1.35 x In@ 40°C|1.35 x In@ 40°C|
|Multi-pole|1.45 x In@ 40°C|1.45 x In@ 40°C|1.45 x In@ 40°C|
|Short-circuit ratings (at max. voltage)||||
|Single-pole|10 kA (5 kA for 40–63A device)|10 kA (5 kA for 40–63A device)|5 kA|
|Two-, three-pole|10 kA (5 kA for 40–63A device)|10 kA (5 kA for 40–63A device)|5 kA|
|Single-pole|10 kA @ 48 Vdc|10 kA @ 48 Vdc|10 kA @ 48 Vdc|
|Two poles in series|10 kA @ 96 Vdc|10 kA @ 96 Vdc|10 kA @ 96 Vdc|
|**Miniature Circuit Breaker—IEC**||||
|Current range|1–63A|0.5–63A|0.5–63A|
|Maximum voltage ratings—IEC 68898-1||||
|Single-pole|230 Vac|230 Vac|230 Vac|
|Two-, three-pole|230/400 Vac|230/400 Vac|230/400 Vac|
|Maximum voltage ratings—IEC 60947-2||||
|Single-pole|240 Vac|240 Vac|240 Vac|
||48 Vdc|48 Vdc|48 Vdc|
|Two-, three-pole|240/415 Vac|240/415 Vac|240/415 Vac|
|Two poles in series|96 Vdc|96 Vdc|96 Vdc|
|Thermal tripping characteristics||||
|Single-pole|> 1 hour @ 1.05 x In|> 1 hour @ 1.05 x In|> 1 hour @ 1.05 x In|
|Multi-pole|< 1 hour @ 1.3 x In|< 1 hour @ 1.3 x In|< 1 hour @ 1.3 x In|
|Interrupt ratings (at max. voltage)||||
|IEC 60947-2|15 kA|15 kA|15 kA (10 kA for 50 and 63A)|
|IEC 60898|10 kA|10 kA|10 kA (50 and 63A not available)|
|Operational switching capacity|7.5 kA|7.5 kA|7.5 kA|
|Max. backup fuse [gL/gG]|125A|125A|125A|
|Rated impulse withstand—_U_imp|4000 Vac|4000 Vac|4000 Vac|
|Rated insulation voltage—_U_i|440 Vac|440 Vac|440 Vac|
|**Environmental/General**||||
|Selectivity class|3|3|3|
|Lifespan (operations)|> 10,000 (1 operation = ON/OFF)|> 10,000 (1 operation = ON/OFF)|> 10,000 (1 operation = ON/OFF)|
|Shock (IEC 68-2-22)|10g–120 ms|10g–120 ms|10g–120 ms|
|Operating temperature range|–40 to +167°F (–40 to +75°C)|–40 to +167°F (–40 to +75°C)|–40 to +167°F (–40 to +75°C)|
|Shipment and short-term storage|–40 to +185°F (–40 to +85°C)|–40 to +185°F (–40 to +85°C)|–40 to +185°F (–40 to +85°C)|
|Housing material|Nylon|Nylon|Nylon|
|**Mechanical**||||
|Standard front dimension||||
|Device height|80 mm|80 mm|80 mm|
|Terminal protection|Finger and back-of-hand proof to IEC 536|Finger and back-of-hand proof to IEC 536|Finger and back-of-hand proof to IEC 536|
|Mounting width per pole|17.5 mm|17.5 mm|17.5 mm|
|Mounting|IEC/EN 60715 top-hat rail|IEC/EN 60715 top-hat rail|IEC/EN 60715 top-hat rail|
|Degree of protection|IP20|IP20|IP20|
|Terminals top and bottom|Twin-purpose terminals|Twin-purpose terminals|Twin-purpose terminals|
|Supply connection|Line or load side|Line or load side|Line or load side|
|Terminal capacity [mm2]|1 x 25 (AWG 4–18)/2 x 10 (AWG 8–18)|1 x 25 (AWG 4–18)/2 x 10 (AWG 8–18)|1 x 25 (AWG 4–18)/2 x 10 (AWG 8–18)|
|Torque|2.4 Nm|2.4 Nm|2.4 Nm|
|Imperial torque|21 lb-in (AWG 18–12), 25 lb-in|21 lb-in (AWG 18–12), 25 lb-in|21 lb-in (AWG 18–12), 25 lb-in|
||(AWG 10–8), 36 lb-in (AWG 6–4)|(AWG 10–8), 36 lb-in (AWG 6–4)|(AWG 10–8), 36 lb-in (AWG 6–4)|
|Thickness of busbar material|0.8–2 mm|0.8–2 mm|0.8–2 mm|
|Mounting position|As required|As required|As required|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-79**
Miniature Circuit Breakers and Supplementary Protectors
UL 1077 DIN Rail Supplementary Protectors
## 1.3
**1**
|**FAZ Miniature Circuit Breakers**<br>**Description**|**Technical Data, continued**<br>**K Curve**|**S Curve**|**Z Curve**|
|---|---|---|---|
|**Electrical**||||
|Approvals|UR (UL 1077), CSA (CSA 22.2 No. 235), CE|||
|Standards|IEC/EN 60947-2, E177451, 204453|||
|Short-circuit trip response<br>**Supplementary Protectors—UL/CSA**|8–12_I_n|13–17_I_n|2–3_I_n|
|Current range|0.5–63A|0.5–40A|1–63A|
|Maximum voltage ratings—UL/CSA||||
|Single-pole, single-pole + neutral|277 Vac<br>48 Vdc|277 Vac<br>48 Vdc|277 Vac<br>48 Vdc|
|Two-, three-, four-pole and||||
|three-pole + neutral<br>Two poles in series|480Y/277 Vac<br>96 Vdc|480Y/277 Vac<br>96 Vdc|480Y/277 Vac<br>96 Vdc|
|Thermal tripping characteristics<br>Single-pole|1.35 x In@ 40°C|1.35 x In@ 40°C|1.35 x In@ 40°C|
|Multi-pole<br>Short-circuit ratings (at max. voltage)|1.45 x In@ 40°C|1.45 x In@ 40°C|1.45 x In@ 40°C|
|Single-pole|5 kA @ 277 Vac|5 kA @ 277 Vac|5 kA @ 277 Vac|
|Single-pole + neutral<br>Two-, three-, four-pole|5 kA @ 277 Vac<br>5 kA @ 480Y/277 Vac|5 kA @ 277 Vac<br>5 kA @ 480Y/277 Vac|5 kA @ 277 Vac<br>5 kA @ 480Y/277 Vac|
|Two poles in series<br>**Miniature Circuit Breaker—IEC**|—|—|—|
|Current range|0.5–63A|0.5–40A|1–63A|
|Maximum voltage ratings—IEC 60947-2||||
|Single-pole, single-pole + neutral<br>Two-, three-, four-pole,|240 Vac|240 Vac|240 Vac|
|three-pole + neutral|240/415 Vac|240/415 Vac|240/415 Vac|
|Thermal tripping characteristics||||
|Single-pole|> 1 Hour @ 1.05 x In|> 1 Hour @ 1.05 x In|> 1 Hour @ 1.05 x In|
|Multi-pole|< 1 Hour @ 1.3 x In|< 1 Hour @ 1.3 x In|< 1 Hour @ 1.3 x In|
|Interrupt ratings (at max. voltage)||||
|IEC 60947-2<br>Operational switching capacity|15 kA<br>7.5 kA|10 kA<br>7.5 kA|10 kA<br>7.5 kA|
|Max. backup fuse [gL/gG]|125A|125A|125A|
|Rated impulse withstand—_U_imp<br>Rated insulation voltage—_U_i|4000 Vac<br>440 Vac|4000 Vac<br>440 Vac|4000 Vac<br>440 Vac|
|**Environmental/General**||||
|Selectivity class|3|3|3|
|Lifespan (operations)<br>Shock (IEC 68-2-22)|> 10,000 (1 operation = ON/OFF)<br>10g–120 ms|> 10,000 (1 operation = ON/OFF)<br>10g–120 ms|> 10,000 (1 operation = ON/OFF)<br>10g–120 ms|
|Operating temperature range|–40 to +167°F (–40 to +75°C)|–40 to +167°F (–40 to +75°C)|–40 to +167°F (–40 to +75°C)|
|Shipment and short-term storage<br>Housing material|–40 to +185°F (–40 to +85°C)<br>Nylon|–40 to +185°F (–40 to +85°C)<br>Nylon|–40 to +185°F (–40 to +85°C)<br>Nylon|
|**Mechanical**||||
|Standard front dimension||||
|Device height<br>Terminal protection|80 mm<br>Finger and back-of-hand proof to IEC 536|80 mm<br>Finger and back-of-hand proof to IEC 536|80 mm<br>Finger and back-of-hand proof to IEC 536|
|Mounting width per pole|17.7 mm|17.7 mm|17.7 mm|
|Mounting|IEC/EN 60715 top-hat rail|IEC/EN 60715 top-hat rail|IEC/EN 60715 top-hat rail|
|Degree of protection|IP20|IP20|IP20|
|Terminals top and bottom<br>Supply connection|Twin-purpose terminals<br>Line or load side|Twin-purpose terminals<br>Line or load side|Twin-purpose terminals<br>Line or load side|
|Terminal capacity [mm2]<br>Torque|1 x 25 (AWG 4–18) / 2 x 10 (AWG 8–18)<br>2.4 Nm|1 x 25 (AWG 4–18) / 2 x 10 (AWG 8–18)<br>2.4 Nm|1 x 25 (AWG 4–18) / 2 x 10 (AWG 8–18)<br>2.4 Nm|
|Imperial torque|21 lb-in (AWG 18–12), 25 lb-in|21 lb-in (AWG 18–12), 25 lb-in|21 lb-in (AWG 18–12), 25 lb-in|
|Thickness of busbar material|(AWG 10–8), 36 lb-in (AWG 6–4)<br>0.8–2 mm|(AWG 10–8), 36 lb-in (AWG 6–4)<br>0.8–2 mm|(AWG 10–8), 36 lb-in (AWG 6–4)<br>0.8–2 mm|
|Mounting position|As required|As required|As required|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-80**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## _**Let-Through Energy I[2] t**_
## **Characteristic B and C**
## _**Let-Through Energy ID**_
## **Characteristic B and C**
**==> picture [483 x 290] intentionally omitted <==**
**----- Start of picture text -----**<br>
[A∫i [2][2] dts] 108 [5] 63 A 50 A [A] l D 1098 [4] 63 A<br>6 40 A 7 40 A [50 A ]<br>32 A 32 A<br>25 A 6 25 A<br>4 20 A 16 A 16 A 20 A<br>13 A 5 13 A<br>10 A 10 A<br>4<br>6 A<br>2 4 A<br>3 A<br>1.5 6 A 4 A 3<br>10 [4] 3 A<br>8 2<br>2 A<br>6<br>2 A 1.5<br>4<br>10 [3]<br>2 1 A<br>1.5 0.5 A<br>1 A<br>10 [3] 0.5 A 5<br>8<br>6<br>4<br>3<br>2<br>0.5 1 1.5 2 3 4 5 6 7 8 910 15 0.5 1 1.5 2 3 4 5 6 7 8 910 15<br>I cc rms [kA] I cc rms [kA]<br>**----- End of picture text -----**<br>
## **Characteristic D**
## **Characteristic D**
**==> picture [487 x 290] intentionally omitted <==**
**----- Start of picture text -----**<br>
[A∫i [2][2] dts] 108 [5] 40 A 32 A 25 A [A] l D 1098 [4] 40 A<br>6 20 A 7 25 A 32 A<br>16 A 20 A<br>13 A 6 16 A<br>4 13 A<br>10 A 5 10 A<br>6 A<br>6 A 4<br>2<br>1.5 3<br>10 [4]<br>8 2<br>6<br>1.5<br>4<br>10 [3]<br>2<br>1.5<br>10 [3]<br>5<br>8<br>6<br>4<br>2<br>0.5 1 1.5 2 3 4 5 6 7 8 910 15 0.5 1 1.5 2 3 4 5 6 7 8 910 15<br>I cc rms [kA] I cc rms [kA]<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-81**
Miniature Circuit Breakers and Supplementary Protectors
UL 1077 DIN Rail Supplementary Protectors
## 1.3
**1**
## _**Let-Through Energy I[2] t**_
## **Characteristic K**
## **Characteristic S**
**==> picture [459 x 300] intentionally omitted <==**
**----- Start of picture text -----**<br>
l D 10 [4] l D 10 [4]<br>[A] [A]<br>8<br>8<br>6 63 A 50 A<br>40 A<br>32 A 6 40 A 32 A<br>4 20 A 13 A [25 A ] 16 A 25 A 20 A<br>16 A<br>10 A 10 A<br>3 6 A 4 A 4<br>6 A<br>4 A<br>2 2 A 3 2 A<br>1.6 A<br>1.5<br>1 A<br>2<br>10 [3] 1 A<br>1.5<br>5 10 [3]<br>0.5 A<br>5<br>0.5 1 1.5 2 3 4 5 6 7 8 9 10<br>I cc rms [kA] 0.5 1 1.5 2 3 4 5 6 7 8 9 10<br>I cc rms [kA]<br>3 A<br>3 A<br>**----- End of picture text -----**<br>
## **Characteristic Z**
**==> picture [216 x 289] intentionally omitted <==**
**----- Start of picture text -----**<br>
l D 10 [4]<br>[A]<br>8<br>6 63 A<br>40 A [50 A ]<br>32 A<br>20 A [25 A ]<br>16 A<br>4<br>10 A<br>8 A<br>3 6 A<br>2<br>4 A<br>1.5<br>2 A<br>10 [3]<br>5<br>1.6 A<br>1 A<br>0.5 A<br>0.5 1 1.5 2 3 4 5 6 7 8 9 10<br>I cc rms [kA]<br>3 A<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-82**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
**Influence of the Ambient Temperature on the Thermal Tripping Behavior** Corrected values of the rated current dependent on the ambient temperature
||**Ambient**|**Temperature T**|**Temperature T**|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**_I_n (A)**|**–40°C**|**–30°C**|**–20°C**|**–10°C**|**0°C**|**10°C**|**20°C**|**30°C**|**35°C**|**40°C**|**45°C**|**50°C**|**55°C**|**60°C**|**65°C**|**70°C**|**75°C**|
|0.16|0.20|0.20|0.19|0.19|0.18|0.17|0.17|0.16|0.16|0.15|0.15|0.15|0.14|0.14|0.14|0.14|0.13|
|0.25|0.32|0.31|0.30|0.29|0.28|0.27|0.26|0.25|0.25|0.24|0.24|0.23|0.23|0.22|0.22|0.21|0.21|
|0.50|0.64|0.62|0.60|0.58|0.56|0.54|0.52|0.50|0.49|0.48|0.47|0.46|0.45|0.44|0.43|0.42|0.41|
|0.75|0.96|0.93|0.90|0.87|0.84|0.81|0.78|0.75|0.74|0.73|0.71|0.69|0.68|0.66|0.65|0.64|0.62|
|1.00|1.30|1.20|1.20|1.20|1.10|1.10|1.00|1.00|0.99|0.97|0.95|0.93|0.90|0.89|0.87|0.85|0.83|
|1.50|1.90|1.90|1.80|1.70|1.70|1.60|1.60|1.50|1.50|1.50|1.40|1.40|1.40|1.30|1.30|1.30|1.20|
|1.60|2.00|2.00|1.90|1.90|1.80|1.70|1.70|1.60|1.60|1.50|1.50|1.50|1.40|1.40|1.40|1.40|1.30|
|2.00|2.60|2.50|2.40|2.30|2.20|2.20|2.10|2.00|2.00|1.90|1.90|1.90|1.80|1.80|1.70|1.70|1.70|
|2.50|3.20|3.10|3.00|2.90|2.80|2.70|2.60|2.50|2.50|2.40|2.40|2.30|2.30|2.20|2.20|2.10|2.10|
|3.00|3.80|3.70|3.60|3.50|3.40|3.30|3.10|3.00|3.00|2.90|2.80|2.80|2.70|2.70|2.60|2.50|2.50|
|3.50|4.50|4.40|4.20|4.10|3.90|3.80|3.70|3.50|3.40|3.40|3.30|3.20|3.20|3.10|3.00|3.00|2.90|
|4.00|5.10|5.00|4.80|4.70|4.50|4.30|4.20|4.00|3.90|3.90|3.80|3.70|3.60|3.50|3.50|3.40|3.30|
|5.00|6.40|6.20|6.00|5.80|5.60|5.40|5.20|5.00|4.90|4.80|4.70|4.60|4.50|4.40|4.30|4.20|4.10|
|6.00|7.70|7.50|7.20|7.00|6.70|6.50|6.30|6.00|5.90|5.80|5.70|5.60|5.40|5.30|5.20|5.10|5.00|
|7.00|9.00|8.70|8.40|8.20|7.80|7.60|7.40|7.00|6.90|6.80|6.70|6.50|6.30|6.20|6.10|6.00|5.80|
|8.00|10.20|9.90|9.60|9.30|9.00|8.70|8.40|8.00|7.90|7.70|7.60|7.40|7.20|7.10|6.90|6.80|6.60|
|10.00|13.00|12.00|12.00|12.00|11.00|11.00|10.00|10.00|9.90|9.70|9.50|9.30|9.00|8.90|8.70|8.50|8.30|
|12.00|15.00|15.00|14.00|14.00|13.00|13.00|13.00|12.00|12.00|12.00|11.00|11.00|11.00|11.00|10.00|10.00|10.00|
|13.00|17.00|16.00|16.00|15.00|15.00|14.00|14.00|13.00|13.00|13.00|12.00|12.00|12.00|12.00|11.00|11.00|11.00|
|15.00|19.00|19.00|18.00|17.00|17.00|16.00|16.00|15.00|15.00|15.00|14.00|14.00|14.00|13.00|13.00|13.00|12.00|
|16.00|20.00|20.00|19.00|19.00|18.00|17.00|17.00|16.00|16.00|15.00|15.00|15.00|14.00|14.00|14.00|14.00|13.00|
|20.00|26.00|25.00|24.00|23.00|22.00|22.00|21.00|20.00|20.00|19.00|19.00|19.00|18.00|18.00|17.00|17.00|17.00|
|25.00|32.00|31.00|30.00|29.00|28.00|27.00|26.00|25.00|25.00|24.00|24.00|23.00|23.00|22.00|22.00|21.00|21.00|
|32.00|41.00|40.00|38.00|37.00|36.00|35.00|33.00|32.00|32.00|31.00|30.00|30.00|29.00|28.00|28.00|27.00|26.00|
|35.00|45.00|43.00|41.00|41.00|38.00|38.00|36.00|35.00|35.00|34.00|33.00|32.00|32.00|32.00|30.00|29.00|29.00|
|40.00|51.00|50.00|48.00|47.00|45.00|43.00|42.00|40.00|39.00|39.00|38.00|37.00|36.00|35.00|35.00|34.00|33.00|
|50.00|64.00|62.00|60.00|58.00|56.00|54.00|52.00|50.00|49.00|48.00|47.00|46.00|45.00|44.00|43.00|42.00|41.00|
|63.00|81.00|78.00|76.00|73.00|71.00|68.00|66.00|63.00|62.00|61.00|60.00|58.00|57.00|56.00|55.00|53.00|52.00|
## **Influence of the Mains Frequency**
Influence of the mains frequency on the tripping behavior IMA of the instantaneous release
|||**Mains**|**Frequency f [Hz]**|**Frequency f [Hz]**|||||
|---|---|---|---|---|---|---|---|---|
|||**16 2/3**|**50**|**60**|**100**|**200**|**300**|**400**|
|_I_MA(f)_I_MA(50|Hz) [%]|91|100|101|106|115|134|141|
## **Load Carrying Capacity of Adjoining Miniature Circuit Breakers**
**==> picture [245 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.00<br>0.90<br>0.80<br>0.70<br>1 2 3 4 5 6 7 8<br>Number of Circuit Breakers<br>Rated Diversity Factor<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-83**
Miniature Circuit Breakers and Supplementary Protectors
1.3
**1**
UL 1077 DIN Rail Supplementary Protectors
## **Accessories Technical Data**
|**Accessories Technical Data**||||
|---|---|---|---|
||**FAZ-XHIN**|||
|**Description**<br>**Electrical**|**FAZ-XAM002**|**FAZ-XAA-C**|**FAZ-XUA**|
|Contact function|1A + 1B<br>2 C/O|—<br>—|—<br>—|
|Rated operational voltage_U_n|250 Vac|—|115 Vac<br>230 Vac|
||||400 Vac|
|Voltage range|—|12–110 Vac|—|
|||12–60 Vdc||
|Voltage range|—|110–415 Vac|—|
|||110–230 Vdc||
|Closing threshold [x_U_n]|—|—|0.8|
|Tripping threshold [x_U_n]<br>Rated frequency ƒ|—<br>50/60 Hz|—<br>50/60 Hz|0.5<br>50/60 Hz|
|General use (UL/CSA)<br>AC—230/240 Vac|2/2A|—|—|
|DC—110/120 Vdc|0.5/0.5A|—|—|
|Pilot duty|A600/Q600|—|—|
|Conventional free air thermal current_I_th<br>Rated operational current|4A|—|—|
|AC-13_I_e<br>AC-15_I_e|3A (250 Vac)<br>2A (250 Vac)|—<br>—|—<br>—|
|DC-13_I_e|0.5A (110 Vdc)|—|—|
|Rated insulation voltage_U_i|250 Vac|—|—|
|Minimum operating voltage per contract_U_min|5 Vdc|—|—|
|Rated impulse withstand voltage (1.2/50μ)_U_imp|2.5 kV|—|—|
|Rated conditional short-circuit current with 6A backup fuse_I_SC<br>Max. admissible backup fuse|1 kA<br>4A gL|—<br>—|—<br>—|
|**Mechanical**||||
|Standard front dimension|45 mm|45 mm|45 mm|
|Device height|80 mm|80 mm|80 mm|
|Mounting width|8.8 mm|17.6 mm|17.8 mm|
|Mounting|On MCB|IEC/EN 60715 top-hat rail|IEC/EN 60715 top-hat rail|
|Degree of protection enclosed|IP40|IP40|IP40|
|Terminal protection|Protection against<br>electric shock to IEC 536|Protection against<br>electric shock to IEC 536|Protection against<br>electric shock to IEC 536|
|Terminals<br>Terminal capacity|Lift terminals|Twin-purpose terminals|Twin-purpose terminals|
|Solid|0.5–2.5 mm2|1–2.5 mm2|2 x (1–2.5) mm2|
|Flexible|0.5–2.5 mm2|1–2.5 mm2|2 x (1–2.5) mm2|
|Tightening torque of terminal screws|0.8–1.0 Nm (7–9 lb-in)|2.4 Nm (21 lb-in)|0.8 Nm (7 lb-in)|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-84**
Miniature Circuit Breakers and Supplementary Protectors
1.3
UL 1077 DIN Rail Supplementary Protectors
**1**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## _**Miniature Circuit Breakers**_
## **FAZ**
**==> picture [413 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.74<br>(9.4)<br>3.15 1.77<br>(80.0) (45.0)<br>1.73<br>1.40 2.09 2.79 (5.5)0.22 (44.0)<br>(35.4) (53.1) (70.8) 2.36<br>0.70<br>(60.0)<br>(17.8)<br>**----- End of picture text -----**<br>
## _**Auxiliary Contacts**_
## **FAZ-XHI11 and FAZ-XH1NW1**
**==> picture [178 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.15 1.77<br>(80.0) (45.0)<br>0.35 0.22 1.73<br>(8.8) (5.5) (44.0)<br>2.36<br>(60.0)<br>**----- End of picture text -----**<br>
## **FAZ-XAM002**
**==> picture [179 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.15 1.77<br>(80.0) (45.0)<br>0.35 0.22 1.73<br>(8.8) (5.5) (44.0)<br>2.36<br>(60.0)<br>**----- End of picture text -----**<br>
## _**Shunt Releases**_
## **FAZ-XAA**
**==> picture [183 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.15 1.77<br>(80.0) (45.0)<br>0.70<br>(17.8) 0.22 1.20 0.39<br>(30.5)<br>(5.5) (10.0)<br>1.03 1.73<br>(26.2) (44.0)<br>2.36<br>(60.0)<br>**----- End of picture text -----**<br>
## _**Undervoltage Releases**_
## **FAZ-XUA**
**==> picture [180 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.15 1.77<br>(80.0) (45.0)<br>0.70<br>(17.8) 0.22 1.73<br>(5.5) (44.0)<br>2.36<br>(60.0)<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-85**
Miniature Circuit Breakers and Supplementary Protectors
**1**
## 1.3
UL 1077 DIN Rail Supplementary Protectors
## Approximate Dimensions in Inches (mm)
## **Busbar and Accessory Weights and Dimensions**
|**Unit Weight (kg)**|**Length**|**Width**|**Height**|**Catalog**<br>**Number**|
|---|---|---|---|---|
|0.29<br>0.64|39.72 (1009.0)<br>39.02 (991.0)|0.59 (15.0)<br>0.87 (22.0)|0.59 (15.0)<br>1.46 (37.0)|**BB-UL-18/1P-1M/57**<br>**BB-UL-18/2P-2M/56**|
|0.83|39.72 (1009.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-18/3P-3M/57**|
|0.26|38.78 (985.0)|0.59 (15.0)|0.59 (15.0)|**BB-UL-18/1P-1.5M/37**|
|0.63|39.72 (1009.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-18/2P+AS-2.5M/46**|
|0.79<br>0.36|38.66 (982.0)<br>39.72 (1009.0)|0.87 (22.0)<br>0.59 (15.0)|1.46 (37.0)<br>0.59 (15.0)|**BB-UL-18/3P+AS-3.5M/48**<br>**BB-UL-25/1P-1M/57**|
|0.79|39.02 (991.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-25/2P-2M/56**|
|1.04|39.72 (1009.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-25/3P-3M/57**|
|0.31|38.78 (985.0)|0.59 (15.0)|0.59 (15.0)|**BB-UL-25/1P-1.5M/37**|
|0.73|39.72 (1009.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-25/2P+AS-2.5M/46**|
|0.97|38.66 (982.0)|0.87 (22.0)|1.46 (37.0)|**BB-UL-25/3P+AS-3.5M/48**|
|0.03<br>0.03|2.36 (60.0)<br>1.42 (36.0)|0.67 (17.0)<br>0.67 (17.0)|1.14 (29.0)<br>1.14 (29.0)|**BB-UL-TEP/35**<br>**BB-UL-TEPA/35**|
|0.03|1.57 (40.0)|0.71 (18.0)|1.18 (30.0)|**BB-UL-TE/50**|
|0.003|3.35 (85.0)|0.47 (12.0)|0.94 (24.0)|**BB-IP/5**|
|0.001|0.55 (14.0)|0.20 (5.0)|0.39 (10.0)|**BB-EV-EC/3**|
|0.001|0.94 (24.0)|0.87 (22.0)|0.39 (10.0)|**BB-UL-EC/1**|
**==> picture [481 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
L W<br>L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 H<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-86**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
## **UL 1053 DIN Rail RCCB**
## **Contents**
**1** _**Description Page**_ UL 1053 DIN Rail RCCB 480/277 Vac **1** Product Selection . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-88** Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-89 1** Technical Data and Specifications . . . . . . . . . . **V4-T1-90** Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-91 1** UL 1053 DIN Rail RCCB 208Y/120 Vac. . . . . . . . . . . . . **V4-T1-93**
## **UL 1053 DIN Rail RCCB 480/277 Vac**
## **Product Overview**
## **Features**
Optimum product quality, ● Wide range of compact tested reliability and safety RCCB types serving as stand for best protection of fault-current and additional installations and plant. protection according to Eaton’s UL 1053 Residual UL 1053 and IEC/EN 61008 Current Circuit Breaker standards, suitable for (RCCB) is designed for use in worldwide use residual current applications. ●
- Type A or Type G/A (with delay) protection available
## **Application Description**
- Comprehensive range of accessories
- Motor control circuits
- HVAC internal/external equipment
- Real contact position indicator
- PLCs
- Fault current tripping indicator
- HMIs
- Equipment protection
- Transparent designation plate
- European housing
## **Standards and Certifications**
- UL 1053
- IEC/EN 61008
- CSA
- ÖVE
- CE Marked
- Trip-free design—RCCB can not be defeated by holding the handle in the ON position
- Captive screws cannot be lost
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-87**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
**1**
## **Product Selection**
## _**UL 1053 RCCB 480Y/277V Type A**_
**Conditionally Surge Current–Proof 250A, Sensitive to Residual Pulsating DC, Type A**
|**Two-Pole**|**Conditionally Surge Current–Proof 250A, Sensitive to Residual Pulsating DC, Type A**<br>**Two-Pole**|
|---|---|
|**Two-Pole**||||
|---|---|---|---|
|**Amperes**|**GF Sensitivity**<br>**(mA)**|**Catalog**<br>**Number**1|**Designation**|
|25<br>40|30<br>300<br>30|**167113**<br>**167116**<br>**167114**|FRCmM-25/2/003-A-NA<br>FRCmM-25/2/03-A-NA<br>FRCmM-40/2/003-A-NA|
||300|**167117**|FRCmM-40/2/03-A-NA|
|63|30|**167115**|FRCmM-63/2/003-A-NA|
||300|**167118**|FRCmM-63/2/03-A-NA|
## **Four-Pole**
**Conditionally Surge Current–Proof 250A, Sensitive to Residual Pulsating DC, Type A**
## **Four-Pole**
|**Amperes**|**Amperes**|**GF Sensitivity**<br>**(mA)**|**Catalog**<br>**Number**1|**Designation**|
|---|---|---|---|---|
|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|
||25|30|**167125**|FRCmM-25/4/003-A-NA|
|||300|**167104**|FRCmM-25/4/03-A-NA|
||40|30|**167102**|FRCmM-40/4/003-A-NA|
|||300|**167105**|FRCmM-40/4/03-A-NA|
||63|30|**167103**|FRCmM-63/4/003-A-NA|
|||300|**167106**|FRCmM-63/4/03-A-NA|
## _**UL 1053 RCCB 480Y/277V Type G/A**_
Type G/A has a 10 ms delay.
**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**
|**Two-Pole**|**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**<br>**Two-Pole**|**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**|**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**|**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**|
|---|---|---|---|---|
|he|**Amperes**|**GF Sensitivity**<br>**(mA)**|**Catalog**<br>**Number**1|**Designation**|
|a)as<br>|ee|25<br>40|30<br>300<br>30|**167119**<br>**167122**<br>**167120**|FRCmM-25/2/003-G/A-NA<br>FRCmM-25/2/03-G/A-NA<br>FRCmM-40/2/003-G/A-NA|
|||300|**167123**|FRCmM-40/2/03-G/A-NA|
||63|30|**167121**|FRCmM-63/2/003-G/A-NA|
|||300|**167124**|FRCmM-63/2/03-G/A-NA|
## **Four-Pole**
**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**
## **Four-Pole**
|**Four-Pole**||||
|---|---|---|---|
|**Amperes**|**GF Sensitivity**<br>**(mA)**|**Catalog**<br>**Number**1|**Designation**|
|25|30<br>300|**167107**<br>**167110**|FRCmM-25/4/003-G/A-NA<br>FRCmM-25/4/03-G/A-NA|
|40|30|**167108**|FRCmM-40/4/003-G/A-NA|
||300|**167111**|FRCmM-40/4/03-G/A-NA|
|63|30|**167109**|FRCmM-63/4/003-G/A-NA|
||300|**167112**|FRCmM-63/4/03-G/A-NA|
## _**Note**_
1 Has no thermal element; must be paired with FAZ-NA or FAZ per application.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-88**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
## **Accessories**
**1**
||**UL 1053 DIN Rail RCCB 480/277 Vac**|**UL 1053 DIN Rail RCCB 480/277 Vac**|||||||
|---|---|---|---|---|---|---|---|---|
||**Description**|**Catalog Number**|||||**Description**|**Catalog Number**|
|**Contact**|Two-pole contact or auxiliary|**Z-NHK**1|**Padlock Hasp**||**Padlock Hasp**||Padlock hasp|**Z-IS/SPE-1TE**|
||contact / trip indicating contact||||||||
|ci if i|||||||||
||||**Lockoff Device**||||UL lockoff device|**FAZPLOFF**|
||||||||||
||||||||||
||||**_Note_**||||||
> 1 Voltage of FAZ-NA circuit breaker is limited to 300V with this auxiliary contact installed.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-89**
Miniature Circuit Breakers and Supplementary Protectors
UL 1053 DIN Rail RCCB
## 1.4
**1**
## **Technical Data and Specifications**
- Residual current devices
- Has no thermal protection; must be paired with FAZ-NA or FAZ per application
- Captive screw terminals
- Universal tripping signal switch, also suitable for Z-A; can be mounted subsequently
- Auxiliary switch Z-HK can be mounted subsequently
- Red-green contact position indicator
- White-blue tripping indicator
- Delayed types recommended for use with standard fluorescent tubes with or without electronical ballast (30mA-RCD: 30 units per phase conductor, 100mA-RCD: 90 units per phase conductor)
- The device functions irrespective of the position of installation
- Tripping is line voltage-independent. Consequently, the RCD is suitable for “fault current/residual current protection” and “additional protection” within the meaning of the applicable installation rules
- Reverse-feed permitted
- The four-pole device can also be used for two-pole connection. For this purpose, use terminals 5-6 and N-N
- The test key “T” must be pressed every month. The system operator must be informed of this obligation and responsibility in a way that can be proven (self-adhesive RCD-label enclosed)
- Pressing the test key “T” serves the only purpose of function testing the residual current device (RCD). This test does not make earthing resistance measurement (RE) or proper checking of the earth conductor condition redundant, which must be performed separately
- **Type -A:** Protects against special forms of residual pulsating DC that have not been smoothed
- **Type -G/A:** Additionally protects against special forms of residual pulsating DC that have not been smoothed
## **UL 1053 DIN Rail RCCB Technical Data**
|||
|---|---|
|**Description**<br>**Specification**||
|**Electrical According to IEC/EN 61008**||
|Design according to<br>IEC/EN 61008<br>ÖVE E 8601||
|Current test marks as printed onto the device||
|Tripping Type G|10 ms delay|
|Rated voltage Un|230/400V, 50 Hz|
|Rated tripping current I�n|30, 300 mA|
|Sensitivity|AC and pulsating DC|
|Rated insulation voltage Ui|440V|
|Rated impulse withstand voltage Uimp|4 kV|
|Rated short-circuit capacity Inc|10 kA|
|Maximum backup fuse<br>In= 25–40A<br>In= 63A|Overload protection<br>Short-circuit protection<br>25A gG/gL<br>63A gG/gL<br>40A gG/gL<br>63A gG/gL|
|Rated breaking capacity Imbzw.<br>Rated fault breaking capacity I�m<br>In= 25–40A<br>In= 63A|500A<br>630A|
|Voltage range of test button|Two-pole<br>184–250V~|
||Four-pole<br>184–440V~|
|Endurance|Electrical<br>>4000 operating cycles|
||Mechanical<br>>20,000 operating cycles|
|Overvoltage category|III|
## **UL 1053 DIN Rail RCCB Technical Data, continued**
|**UL 1053 DIN Rail RCCB Technical Data, continued**|**UL 1053 DIN Rail RCCB Technical Data, continued**|
|---|---|
|**Description**<br>**Specification**||
|**Electrical According to UL 1053**||
|Design according to<br>UL 1053||
|Current test marks as printed onto the device||
|Tripping Type G|8 ms delay|
|Rated voltage Un|480Y/277V, 60 Hz|
|Pickup current|22, 200 mA|
|Sensitivity|AC and pulsating DC|
|Overvoltage tested|530V|
|Rated impulse withstand voltage Uimp|4 kV|
|Rated short-circuit capacity Inc|5 kA according to CSA|
|Maximum backup fuse<br>In= 25–40A<br>In= 63A|Overload protection<br>Short-circuit protection<br>25A gG/gL<br>63A gG/gL<br>40A gG/gL<br>63A gG/gL|
|Rated breaking capacity Imor<br>Rated fault breaking capacity I�m<br>In= 25–40A<br>In= 63A|500A<br>630A|
|Voltage range of test button|Two-pole<br>184–305V~|
||Four-pole<br>184–528V~|
|Endurance|Electrical<br>>4000 operating cycles|
||Mechanical<br>>20,000 operating cycles|
|**Mechanical**||
|Frame size|45.0 mm|
|Device height|80.0 mm|
|Device width|35 mm (2TE), 70 mm (4TE)|
|Device width|Quick fastening with two<br>lock-in positions on DIN<br>rail IEC/EN 60715|
|Degree of protection, built-in|IP40|
|Degree of protection in moisture-proof<br>enclosure|IP54|
|Upper and lower terminals|Lift terminals|
|Terminal protection|Finger and hand touch<br>safe BGV A3, ÖVE-EN 6|
|Terminal capacity|1.5–35 mm2single-wire|
||2 x 16 mm2multi-wire|
|Busbar material thickness|0.8–2 mm|
|Tripping temperature|–25°C to +60°C|
|Resistance to climatic conditions|According to IEC 61008|
|Humidity|5–95%|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-90**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
**1**
## **Connection Diagram**
**==> picture [215 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 N 1 3 5 N<br>T T<br>2 N 2 4 6 N<br>Two-Pole Four-Pole<br>**----- End of picture text -----**<br>
## **Impact of Ambient Temperature on the Maximum Permanent Current Allowed (A)**
||**16A**||**25A**||**40A**||**63A**||
|---|---|---|---|---|---|---|---|---|
|**Tripping**|**Two-**|**Four-**|**Two-**|**Four-**|**Two-**|**Four-**|**Two-**|**Four-**|
|**Temperature**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|
|40°C|16|16|25|25|40|40|63|63|
|45°C|14|14|21|22|37|37|59|59|
|50°C|11|11|18|19|33|34|55|55|
|55°C|9|9|14|16|30|31|50|50|
|60°C|1|—|—|—|26|27|45|45|
## _**Notes**_
> 1 Do not use.
Please make sure that these values are not exceeded and that any upstream overload protection switches off in time.
## **Correct Connection**
**==> picture [240 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
3+N Three-phase load without N<br>(230/400V) IEC (184–254 Vac Phase-Phase) IEC<br>(277/480V) UL (184–277 Vac Phase-Phase) UL<br>**----- End of picture text -----**<br>
**==> picture [238 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
Three-phase load without N 1+N<br>(400 Vac Phase-Phase) IEC (230V) IEC<br>(480 Vac Phase-Phase) UL (277V) UL<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **UL 1053 DIN Rail RCCB**
**==> picture [240 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.22 0.18<br>(5.5) (4.5)<br>1.20<br>(30.5)<br>3.15 1.77<br>(80.0) (45.0)<br>0.41<br>2.76 1.73 (10.5)<br>(70.0) (44.0)<br>2.36<br>Four-Pole (60.0)<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-91**
Miniature Circuit Breakers and Supplementary Protectors UL 1053 DIN Rail RCCB
## 1.4
**1**
|**Accessories Technical Data**<br>**Description**|**Z-NHK**|
|---|---|
|**Electrical**||
|Contact function|2CO|
|Rated voltage|230V|
|Frequency|50/60 Hz|
|Rated current|2A|
|Rated thermal current Ith|2A|
|Utilization category AC13||
|Rated operational current Ie|3A/250 Vac|
|Utilization category AC15<br>Rated operational current Ie|2A/250 Vac|
|Utilization category DC12<br>Rated operational current Ie|0.5A/110 Vdc|
|Rated insulation voltage UI<br>Minimum operational voltage per contact Umin|250 Vac<br>5 Vdc|
|Minimum operational current Imin<br>Rated peak withstand voltage Uimp(1.2/50μ)|10 mA DC<br>2.5 kV|
|Conditional short-circuit current Ikwith backup fuse 6A|1 kA|
|Maximum backup fuse, overload and short circuit|6A gL|
|**Mechanical**||
|Tripping indicator “electrical tripping”|Blue/white|
|Frame size|45 mm|
|Device height|80 mm|
|Device width|8.8 mm (0.5MU)|
|Mounting|Onto switching device|
|Degree of protection, built-in|IP40|
|Terminal protection|Finger and hand touch safe|
||According to BGV A3, ÖVE-EN 6|
|Terminals|Lift terminals|
|Terminal capacity|20–14 AWG|
|Terminal screws|M3 (Posidrive Z0)|
|Fastening torque of terminal screws|7 lb-in maximum|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-92**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
## **UL 1053 DIN Rail RCCB**
## **Contents**
**1** _**Page**_ **V4-T1-87 1**
## _**Description**_
UL 1053 DIN Rail RCCB 480/277 Vac . . . . . . . . . . **V4-T1-87** UL 1053 DIN Rail RCCB 208Y/120 Vac Product Selection . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-94** Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-95** Technical Data and Specifications. . . . . . . . . . . . **V4-T1-96** Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . **V4-T1-97**
## **UL 1053 DIN Rail RCCB 208Y/120 Vac**
## **Product Overview**
Optimum product quality, tested reliability and safety stand for best protection of installations and plant. Eaton’s UL 1053 Residual Current Circuit Breaker (RCCB) is designed for use in residual current applications.
## **Application Description**
- Motor control circuits
- HVAC internal/external equipment
- PLCs
- HMIs
- Equipment protection
## **Features**
- Wide range of compact RCD type serving as faultcurrent and additional protection according to UL 1053 and IEC/EN 61008 standards, suitable for worldwide use in the 110V range of applications
- Type A or Type G/A (with delay) protection available
- Comprehensive range of accessories
- Real contact position indicator
- Fault current tripping indicator
## **Standards and Certifications**
- UL 1053
- IEC/EN 61008
- Transparent designation plate
- Trip-free design—RCCB can not be defeated by holding the handle in the ON position
- Captive screws cannot be lost
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-93**
Miniature Circuit Breakers and Supplementary Protectors UL 1053 DIN Rail RCCB
1.4
**1**
## **Product Selection**
## _**UL 1053 RCCB 208Y/120 Vac Type A**_
**Conditionally Surge Current–Proof 250A, Sensitive to Residual Pulsating DC, Type A**
## **Four-Pole Four-Pole**
|**Four-Pole**||||
|---|---|---|---|
||**GF Sensitivity**|**Catalog**||
|**Amperes**|**(mA)**|**Number**1|**Designation**|
|25|30|**167699**|FRCmM-25/4/003-A-NA-110|
|40|300<br>30|**167702**<br>**167700**|FRCmM-25/4/03-A-NA-110<br>FRCmM-40/4/003-A-NA-110|
||300|**167703**|FRCmM-40/4/03-A-NA-110|
|63|30|**167701**|FRCmM-63/4/003-A-NA-110|
||300|**167704**|FRCmM-63/4/03-A-NA-110|
## _**UL 1053 RCCB 208Y/120 Vac Type G/A**_
Type G/A has a 10 ms delay.
## **Two-Pole**
**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**
|**Two-Pole**||||
|---|---|---|---|
||**GF Sensitivity**|**Catalog**||
|**Amperes**|**(mA)**|**Number**1|**Designation**|
|25<br>40|30<br>**167693**<br>FRCmM-25/2/003-G/A-NA-110<br>300<br>**167696**<br>FRCmM-25/2/03-G/A-NA-110<br>30<br>**167694**<br>FRCmM-40/2/003-G/A-NA-110<br>~~a~~|||
||300|**167697**|FRCmM-40/2/03-G/A-NA-110|
|63|30|**167695**|FRCmM-63/2/003-G/A-NA-110|
||300|**167698**|FRCmM-63/2/03-G/A-NA-110|
## **Four-Pole**
**Surge Current–Proof 3 kA, Sensitive to Residual Pulsating DC, Type G/A (ÖVE E 8601)**
## **Four-Pole**
|**Four-Pole**||||
|---|---|---|---|
||**GF Sensitivity**|**Catalog**||
|**Amperes**|**(mA)**|**Number**1|**Designation**|
|25|30|**167705**|FRCmM-25/4/003-G/A-NA-110|
||300|**167708**|FRCmM-25/4/03-G/A-NA-110|
|40|30<br>300|**167706**<br>**167709**|FRCmM-40/4/003-G/A-NA-110<br>FRCmM-40/4/03-G/A-NA-110|
|63|30|**167707**|FRCmM-63/4/003-G/A-NA-110|
||300|**167710**|FRCmM-63/4/03-G/A-NA-110|
## _**Note**_
1 Has no thermal element; must be paired with FAZ-NA or FAZ per application.
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-94**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
## **Accessories**
**1**
## **UL 1053 DIN Rail RCCB 208Y/120 Vac**
||**Description**|**Catalog Number**||||**Description**|**Catalog Number**|
|---|---|---|---|---|---|---|---|
|**Contact**|Two-pole contact or auxiliary|**Z-NHK**1|**Padlock Hasp**|||Padlock hasp|**Z-IS/SPE-1TE**|
||contact / trip indicating contact||**Lockoff Device**<br>ffr*)<br>|||UL lockoff device<br> ~~OS~~|**FAZPLOFF**|
||||||—L fly|||
|||||||||
|||||||||
||||**_Note_**|||||
||||1|Voltage of FAZ-NA circuit breaker is limited to 300V with this auxiliary contact installed.|||Voltage of FAZ-NA circuit breaker is limited to 300V with this auxiliary contact installed.|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-95**
Miniature Circuit Breakers and Supplementary Protectors
UL 1053 DIN Rail RCCB
## 1.4
**1**
## **Technical Data and Specifications**
- Residual current devices
- Has no thermal protection; must be paired with FAZ-NA or FAZ per application
- Captive screw terminals
- Universal tripping signal switch, also suitable for Z-A; can be mounted subsequently
- Auxiliary switch Z-HK can be mounted subsequently
- Red-green contact position indicator
- White-blue tripping indicator
- Delayed types recommended for use with standard fluorescent tubes with or without electronical ballast (30mA-RCD: 30 units per phase conductor, 100mA-RCD: 90 units per phase conductor)
- The device functions irrespective of the position of installation
- Tripping is line voltage-independent. Consequently, the RCD is suitable for “fault current/residual current protection” and “additional protection” within the meaning of the applicable installation rules
- Reverse-feed permitted
- The four-pole device can also be used for two-pole connection. For this purpose, use terminals 5-6 and N-N
- The test key “T” must be pressed every month. The system operator must be informed of this obligation and responsibility in a way that can be proven (self-adhesive RCD-label enclosed)
- Pressing the test key “T” serves the only purpose of function testing the residual current device (RCD). This test does not make earthing resistance measurement (RE) or proper checking of the earth conductor condition redundant, which must be performed separately
- **Type -A:** Protects against special forms of residual pulsating DC that have not been smoothed
- **Type -G/A:** Additionally protects against special forms of residual pulsating DC that have not been smoothed
## **UL 1053 DIN Rail RCCB Technical Data**
|||
|---|---|
|**Description**<br>**Specification**||
|**Electrical According to IEC/EN 61008**||
|Design according to<br>IEC/EN 61008<br>ÖVE E 8601||
|Current test marks as printed onto the device||
|Tripping Type G|10 ms delay|
|Rated voltage Un|230/400V, 50 Hz|
|Rated tripping current I�n|30, 300 mA|
|Sensitivity|AC and pulsating DC|
|Rated insulation voltage Ui|440V|
|Rated impulse withstand voltage Uimp|4 kV|
|Rated short-circuit capacity Inc|10 kA|
|Maximum backup fuse<br>In= 25–40A<br>In= 63A|Overload protection<br>Short-circuit protection<br>25A gG/gL<br>63A gG/gL<br>40A gG/gL<br>63A gG/gL|
|Rated breaking capacity Imbzw.<br>Rated fault breaking capacity I�m<br>In= 25–40A<br>In= 63A|500A<br>630A|
|Voltage range of test button|Two-pole<br>100–132V~|
||Four-pole<br>100–230V~|
|Endurance|Electrical<br>>4000 operating cycles|
||Mechanical<br>>20,000 operating cycles|
|Overvoltage category|III|
## **UL 1053 DIN Rail RCCB Technical Data, continued**
|**UL 1053 DIN Rail RCCB Technical Data, continued**|**UL 1053 DIN Rail RCCB Technical Data, continued**|
|---|---|
|**Description**<br>**Specification**||
|**Electrical According to UL1053**||
|Design according to<br>UL 1053||
|Current test marks as printed onto the device||
|Tripping Type G|8 ms delay|
|Rated voltage Un|208Y/120V, 60 Hz|
|Pickup current|22, 200 mA|
|Sensitivity|AC and pulsating DC|
|Overvoltage tested|530V|
|Rated impulse withstand voltage Uimp|4 kV|
|Rated short-circuit capacity Inc|5 kA according to CSA|
|Maximum backup fuse<br>In= 25–40A<br>In= 63A|Overload protection<br>Short-circuit protection<br>25A gG/gL<br>63A gG/gL<br>40A gG/gL<br>63A gG/gL|
|Rated breaking capacity Imor<br>Rated fault breaking capacity I�m<br>In= 25–40A<br>In= 63A|500A<br>630A|
|Voltage range of test button|Two-pole<br>100–121V~|
||Four-pole<br>100–210V~|
|Endurance|Electrical<br>>4000 operating cycles|
||Mechanical<br>>20,000 operating cycles|
|**Mechanical**||
|Frame size|45.0 mm|
|Device height|80.0 mm|
|Device width|35 mm (2TE), 70 mm (4TE)|
|Device width|Quick fastening with two<br>lock-in positions on DIN<br>rail IEC/EN 60715|
|Degree of protection, built-in|IP40|
|Degree of protection in moisture-proof<br>enclosure|IP54|
|Upper and lower terminals|Lift terminals|
|Terminal protection|Finger and hand touch<br>safe BGV A3, ÖVE-EN 6|
|Terminal capacity|1.5–35 mm2single-wire|
||2 x 16 mm2multi-wire|
|Busbar material thickness|0.8–2 mm|
|Tripping temperature|–25°C to +60°C|
|Resistance to climatic conditions|According to IEC 61008|
|Humidity|5–95%|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-96**
Miniature Circuit Breakers and Supplementary Protectors
1.4
UL 1053 DIN Rail RCCB
**1**
## **Connection Diagram**
**==> picture [215 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 N 1 3 5 N<br>T T<br>2 N 2 4 6 N<br>Two-Pole Four-Pole<br>**----- End of picture text -----**<br>
## **Impact of Ambient Temperature on the Maximum Permanent Current Allowed (A)**
||**16A**||**25A**||**40A**||**63A**||
|---|---|---|---|---|---|---|---|---|
|**Tripping**|**Two-**|**Four-**|**Two-**|**Four-**|**Two-**|**Four-**|**Two-**|**Four-**|
|**Temperature**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|**Pole**|
|40°C|16|16|25|25|40|40|63|63|
|45°C|14|14|21|22|37|37|59|59|
|50°C|11|11|18|19|33|34|55|55|
|55°C|9|9|14|16|30|31|50|50|
|60°C|1|—|—|—|26|27|45|45|
## _**Notes**_
> 1 Do not use.
Please make sure that these values are not exceeded and that any upstream overload protection switches off in time.
## **Correct Connection**
**==> picture [240 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
3+N Three-phase load without N<br>(230/400V) IEC (184–254 Vac Phase-Phase) IEC<br>(277/480V) UL (184–277 Vac Phase-Phase) UL<br>**----- End of picture text -----**<br>
**==> picture [238 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
Three-phase load without N 1+N<br>(400 Vac Phase-Phase) IEC (230V) IEC<br>(480 Vac Phase-Phase) UL (277V) UL<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **UL 1053 DIN Rail RCCB**
**==> picture [240 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.22 0.18<br>(5.5) (4.5)<br>1.20<br>(30.5)<br>3.15 1.77<br>(80.0) (45.0)<br>0.41<br>2.76 1.73 (10.5)<br>(70.0) (44.0)<br>2.36<br>Four-Pole (60.0)<br>**----- End of picture text -----**<br>
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-97**
Miniature Circuit Breakers and Supplementary Protectors UL 1053 DIN Rail RCCB
## 1.4
**1**
|**Accessories Technical Data**<br>**Description**|**Z-NHK**|**Z-IHK-NA**|
|---|---|---|
|**Electrical**|||
|Contact function|2CO|1NO + 1NC|
|Rated voltage|230V|250V|
|Frequency|50/60 Hz|50/60 Hz|
|Rated current|2A|6A|
|Rated thermal current Ith|2A|6A|
|Utilization category AC13|||
|Rated operational current Ie|3A/250 Vac|3A/250 Vac|
|Utilization category AC15<br>Rated operational current Ie|2A/250 Vac|2A/250 Vac|
|Utilization category DC12<br>Rated operational current Ie|0.5A/110 Vdc|0.5A/110 Vdc|
|||0.25A/220 Vdc|
|Rated insulation voltage UI|250 Vac|250 Vac|
|Minimum operational voltage per contact Umin<br>Minimum operational current Imin|5 Vdc<br>10 mA DC|5 Vdc<br>10 mA AC/DC|
|Rated peak withstand voltage Uimp(1.2/50μ)<br>Conditional short-circuit current Ikwith backup fuse 6A|2.5 kV<br>1 kA|4 kV<br>1 kA|
|Maximum backup fuse, overload and short circuit<br>**Mechanical**|6A gL|—|
|Tripping indicator “electrical tripping”<br>Frame size|Blue/white<br>45 mm|—<br>45 mm|
|Device height<br>Device width|80 mm<br>8.8 mm (0.5MU)|80 mm<br>8.8 mm (0.5MU)|
|Mounting|Onto switching device|—|
|Degree of protection, built-in|IP40|IP40|
|Terminal protection|Finger and hand touch safe<br>According to BGV A3, ÖVE-EN 6|Finger and hand touch safe<br>According to BGV A3, ÖVE-EN 6|
|Terminals<br>Terminal capacity|Lift terminals<br>20–14 AWG|Lift terminals<br>0.5–2.5 mm2|
|Terminal screws|M3 (Posidrive Z0)|M3 (Posidrive Z0)|
|Fastening torque of terminal screws|7 lb-in maximum|1.2 Nm|
**Volume 4—Circuit Protection** CA08100005E—November 2016 www.eaton.com
**V4-T1-98**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →