- Manufacturer: EATON CUTLER HAMMER
- Product type: Thermal Magnetic Circuit Breakers
- Produc; THERMAL MAGNETIC CIRCUIT BREAKER; Product Range:FAZ Series; Current Rating:20A; No. of Poles:1 Pole; Voltage Rating VDC:48V; Voltage Rating VAC:480V; Circuit Breaker Mounting:DIN
- No. of Poles: 1 Pole
- Product Range: FAZ Series
- Current Rating: 20A
- Voltage Rating VAC: 480V
- Voltage Rating VDC: 48V
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 33.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
**www.moeller.net**
## **X** _**pole**_ **Industrial**
## **Feeder and Branch Circuit Breaker**
Xpole Industrial, the logical continuation of the development of installation products for industrial applications. From protective switches to modular installation devices to surge protection, everything matches, and the complete range combines all the benefits.
## **X** _**pole**_ **Industrial**
## **Product Information**
Feeder and Branch Circuit Breaker FAZ-NA FAZ-RT (Ring Tonque Connection)
## **Optimum and Efficient Protection for Every Application**
## When it comes to protection and switching, industries in many countries rely on Moeller products.
Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Approvals in many countries confirm Moeller builts its products to comply with the latest national and international Regulations.
## **Powerful offering for machine and system builders**
The X _pole_ Industrial FAZ-NA, FAZ-RT is available with C and D characteristic in accordance with UL 489, CSA C22.2 No.5; UL 1077, CSA C22.2 No.235 and IEC 60947-2
## **Typical Applications**
## **Feeder and Branch Circuit Protection**
- Convenience receptacle circuits (internal/external)
## **10 kA** UL 489, C22.2 No.5
- Motors (internal/external)
- Load circuits leaving the equipment (external)
## **15 kA** IEC 60947-2
- HACR Equipment (Heating, Air Conditioning, Refrigeration) (internal/external)
## **Supplementary Protection FAZ, FAZ-NA and FAZ-RT**
- Additional protection for: sensitive equipment, electronic components (e.g. computers)
- Motor control circuits without transformers
2
## Features
- Current limiting
Captive screws cannot be lost
- SWD (switching duty) – suitable for switching fluorescent lighting loads (In ≤ 20 A)
## FAZ-NA
- Fulfill UL 489, CSA C22.2 No. 5 and also IEC 60947-2 Standard
- For use in application for which UL 1077 or CSA C22.2 No.235 are also allowed
- Shunt trip release and auxiliary switch for subsequent mounting
- Separate Version for Ring Tonque Connection (Type FAZ-….-RT), terminal screws can be removed (on both sides)
- Module width of only 17,7 mm (per pole)
## FAZ-RT
- Contact Position Indicator (red/green)
- Easy installation on DIN rail
- Possibility for sealing the toggle in on- or off-position
## FAZ-RT
3
## **FAZ complies with the latest national and international Standards**
Standards – Feeder and Branch Circuit Protection ~~Ce~~
## • **UL 489**
Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection.
**==> picture [23 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>L<br>**----- End of picture text -----**<br>
Products meet the requirements of the National Electrical Code (NEC).
## • **CSA C22.2 No.5**
Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection (corresponds closely to UL 489 Standard).
Products meet the requirements of the Canadian Electrical Code (CEC)
Standards – Supplementary Protection ~~Ce~~
## • **UL 1077**
Standard for molded case circuit breakers (MCCB) for supplementary protection of sensitive elctronic equipment or equipment that requires unique or specific overcurrent protection.
Products meet the requirements of the National Electrical Code (NEC).
## • **CSA C22.2 No.235**
Equivalent to the UL 1077 Standard.
Products meet the requirements of the Canadian Electrical Code (CEC).
4
## Device Printing on front and side
Rated Voltage Heating, Air Conditioning, Type Designation Oe ee UL/CSA Refrigeration (t+eee -” ee, Min. distance between front >> 5. |/yy ee. » ’ plate and deFAZ-C20/1-NA =~ /ISSUE/NO. AB-5430 ——— EAN-Code vice shoulder Made in Spain | POLE UNIT GRe —_——_ * According to Rated Standard pe Sgt | USTED, |CIRCUIT BREAKER D'S! = Breaking IEC/EN Capacity UL/CSA Rated Voltage Current IEC/EN Limiting S min. 0.25 in/6mm! |mue—zoan 7 — sr Switching Rated Breaking Duty Capacity IEC/EN Icu=15kA240/415V~Ics=7,5kA50/60HZ |), a6 ein —_—— .10 Terminal Reference Capacity CalibrationTemperature as W2mm/O5in | Se Rated Impulse 2m Utilisation aes German Suitable for Length of | Withstand Category Approval 60/75°C wire uninsulated Voltage Mark conductor Cu-conductors mi *« only Calibration Temperature acc. | UL/CSARated Voltage J Suitable for UL/CSA Insolation Rated Current
EAN-Code
5
##
Miniature Circuit Breakers FAZ - NA 15 kA IEC; 10 kA UL/CSA, Characteristic C
|SG11805||Rated current In(A)<br>1-pole<br>0.5|Type Designation<br>FAZ-C0,5/1-NA|Article No.<br>102077|Units per package<br>2 / 80|
|---|---|---|---|---|---|
|||1|FAZ-C1/1-NA|102078|2 / 80|
|||1.5|FAZ-C1,5/1-NA|102079|2 / 80|
|||2|FAZ-C2/1-NA|102080|2 / 80|
|||3|FAZ-C3/1-NA|102081|2 / 80|
|||4|FAZ-C4/1-NA|102082|2 / 80|
|||5|FAZ-C5/1-NA|102083|2 / 80|
||wl|6|FAZ-C6/1-NA|102084|2 / 80|
|||7|FAZ-C7/1-NA|102085|2 / 80|
|||8|FAZ-C8/1-NA|102086|2 / 80|
|||10|FAZ-C10/1-NA|102087|2 / 80|
|||13|FAZ-C13/1-NA|102088|2 / 80|
|||15|FAZ-C15/1-NA|102089|2 / 80|
|||16|FAZ-C16/1-NA|102090|2 / 80|
|||20|FAZ-C20/1-NA|102091|2 / 80|
|||25|FAZ-C25/1-NA|102092|2 / 80|
|||30|FAZ-C30/1-NA|102093|2 / 80|
|||32|FAZ-C32/1-NA|102094|2 / 80|
|||35|FAZ-C35/1-NA|102095|2 / 80|
|||40|FAZ-C40/1-NA|102096|2 / 80|
|SG12105||2-pole||||
|||0.5|FAZ-C0,5/2-NA|102157|1 / 40|
|||1|FAZ-C1/2-NA|102158|1 / 40|
|||1.5|FAZ-C1,5/2-NA|102159|1 / 40|
|||2|FAZ-C2/2-NA|102160|1 / 40|
|||3|FAZ-C3/2-NA|102161|1 / 40|
|||4|FAZ-C4/2-NA|102162|1 / 40|
|||5|FAZ-C5/2-NA|102163|1 / 40|
|||6|FAZ-C6/2-NA|102164|1 / 40|
|||7|FAZ-C7/2-NA|102165|1 / 40|
|||8|FAZ-C8/2-NA|102166|1 / 40|
|||10|FAZ-C10/2-NA|102167|1 / 40|
|||13|FAZ-C13/2-NA|102168|1 / 40|
|||15|FAZ-C15/2-NA|102169|1 / 40|
|||16|FAZ-C16/2-NA|102170|1 / 40|
|||20|FAZ-C20/2-NA|102171|1 / 40|
|||25|FAZ-C25/2-NA|102172|1 / 40|
|||30|FAZ-C30/2-NA|102173|1 / 40|
|||32|FAZ-C32/2-NA|102174|1 / 40|
|||35|FAZ-C35/2-NA|102175|1 / 40|
|||40|FAZ-C40/2-NA|102176|1 / 40|
|SG12205||3-pole||||
|||0.5|FAZ-C0,5/3-NA|102237|1 / 28|
|||1|FAZ-C1/3-NA|102238|1 / 28|
|||1.5|FAZ-C1,5/3-NA|102239|1 / 28|
|||2|FAZ-C2/3-NA|102240|1 / 28|
|||3|FAZ-C3/3-NA|102241|1 / 28|
|||4|FAZ-C4/3-NA|102242|1 / 28|
|||5|FAZ-C5/3-NA|102243|1 / 28|
|||6|FAZ-C6/3-NA|102244|1 / 28|
|||7|FAZ-C7/3-NA|102245|1 / 28|
|||8|FAZ-C8/3-NA|102246|1 / 28|
|||10|FAZ-C10/3-NA|102247|1 / 28|
|||13|FAZ-C13/3-NA|102248|1 / 28|
|||15|FAZ-C15/3-NA|102249|1 / 28|
|||16|FAZ-C16/3-NA|102250|1 / 28|
|||20|FAZ-C20/3-NA|102251|1 / 28|
|||25|FAZ-C25/3-NA|102252|1 / 28|
|||30|FAZ-C30/3-NA|102253|1 / 28|
|||32|FAZ-C32/3-NA|102254|1 / 28|
|||35|FAZ-C35/3-NA|102255|1 / 28|
|||40|FAZ-C40/3-NA|102256|1 / 28|
6
Miniature Circuit Breakers FAZ - NA 15 kA IEC; 10 kA UL/CSA, Characteristic D
|||Rated current In(A)|Type Designation|Article No.|Units per package|
|---|---|---|---|---|---|
|||1-pole||||
|SG11805||||||
|||0.5|FAZ-D0,5/1-NA|102097|2 / 80|
|||1|FAZ-D1/1-NA|102098|2 / 80|
|||1.5|FAZ-D1,5/1-NA|102099|2 / 80|
|||2|FAZ-D2/1-NA|102100|2 / 80|
|||3|FAZ-D3/1-NA|102101|2 / 80|
|||4|FAZ-D4/1-NA|102102|2 / 80|
|||5|FAZ-D5/1-NA|102103|2 / 80|
||q|6|FAZ-D6/1-NA|102104|2 / 80|
|||7|FAZ-D7/1-NA|102105|2 / 80|
|||8|FAZ-D8/1-NA|102106|2 / 80|
|||10|FAZ-D10/1-NA|102107|2 / 80|
|||13|FAZ-D13/1-NA|102108|2 / 80|
|||15|FAZ-D15/1-NA|102109|2 / 80|
|||16|FAZ-D16/1-NA|102110|2 / 80|
|||20|FAZ-D20/1-NA|102111|2 / 80|
|||25|FAZ-D25/1-NA|102112|2 / 80|
|||30|FAZ-D30/1-NA|102113|2 / 80|
|||32|FAZ-D32/1-NA|102114|2 / 80|
|||35|FAZ-D35/1-NA|102115|2 / 80|
|||40|FAZ-D40/1-NA|102116|2 / 80|
|SG12105||2-pole||||
|||0.5|FAZ-D0,5/2-NA|102177|1 / 40|
|||1|FAZ-D1/2-NA|102178|1 / 40|
|||1.5|FAZ-D1,5/2-NA|102179|1 / 40|
|||2|FAZ-D2/2-NA|102180|1 / 40|
|||3|FAZ-D3/2-NA|102181|1 / 40|
|||4|FAZ-D4/2-NA|102182|1 / 40|
|||5|FAZ-D5/2-NA|102183|1 / 40|
|||6|FAZ-D6/2-NA|102184|1 / 40|
|||7|FAZ-D7/2-NA|102185|1 / 40|
|||8|FAZ-D8/2-NA|102186|1 / 40|
|||10|FAZ-D10/2-NA|102187|1 / 40|
|||13|FAZ-D13/2-NA|102188|1 / 40|
|||15|FAZ-D15/2-NA|102189|1 / 40|
|||16|FAZ-D16/2-NA|102190|1 / 40|
|||20|FAZ-D20/2-NA|102191|1 / 40|
|||25|FAZ-D25/2-NA|102192|1 / 40|
|||30|FAZ-D30/2-NA|102193|1 / 40|
|||32|FAZ-D32/2-NA|102194|1 / 40|
|||35|FAZ-D35/2-NA|102195|1 / 40|
|||40|FAZ-D40/2-NA|102196|1 / 40|
|SG12205||3-pole||||
|||0.5|FAZ-D0,5/3-NA|102257|1 / 28|
|||1|FAZ-D1/3-NA|102258|1 / 28|
|||1.5|FAZ-D1,5/3-NA|102259|1 / 28|
|||2|FAZ-D2/3-NA|102260|1 / 28|
|||3|FAZ-D3/3-NA|102261|1 / 28|
|||4|FAZ-D4/3-NA|102262|1 / 28|
|||5|FAZ-D5/3-NA|102263|1 / 28|
|||6|FAZ-D6/3-NA|102264|1 / 28|
|||7|FAZ-D7/3-NA|102265|1 / 28|
|||8|FAZ-D8/3-NA|102266|1 / 28|
|||10|FAZ-D10/3-NA|102267|1 / 28|
|||13|FAZ-D13/3-NA|102268|1 / 28|
|||15|FAZ-D15/3-NA|102269|1 / 28|
|||16|FAZ-D16/3-NA|102270|1 / 28|
|||20|FAZ-D20/3-NA|102271|1 / 28|
|||25|FAZ-D25/3-NA|102272|1 / 28|
|||30|FAZ-D30/3-NA|102273|1 / 28|
|||32|FAZ-D32/3-NA|102274|1 / 28|
|||35|FAZ-D35/3-NA|102275|1 / 28|
|||40|FAZ-D40/3-NA|102276|1 / 28|
7
## Miniature Circuit Breakers FAZ - NA - DC
125 V DC; 10 kA UL489A, Characteristic C
SG11905 |
|Rated current In(A)<br>1-pole<br>2<br>3<br>4<br>5|Type Designation<br>FAZ-C2/1-NA-DC<br>FAZ-C3/1-NA-DC<br>FAZ-C4/1-NA-DC<br>FAZ-C5/1-NA-DC|Article No.<br>113752<br>113753<br>113754<br>113755|Units per package<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80|
|---|---|---|---|
|6|FAZ-C6/1-NA-DC|113756|2 / 80|
|7|FAZ-C7/1-NA-DC|113757|2 / 80|
|8|FAZ-C8/1-NA-DC|113758|2 / 80|
|10|FAZ-C10/1-NA-DC|113759|2 / 80|
|13|FAZ-C13/1-NA-DC|113760|2 / 80|
|15|FAZ-C15/1-NA-DC|113761|2 / 80|
|16|FAZ-C16/1-NA-DC|113762|2 / 80|
|20|FAZ-C20/1-NA-DC|113763|2 / 80|
|25|FAZ-C25/1-NA-DC|113764|2 / 80|
|30|FAZ-C30/1-NA-DC|113765|2 / 80|
|32|FAZ-C32/1-NA-DC|113766|2 / 80|
|35|FAZ-C35/1-NA-DC|113767|2 / 80|
|40|FAZ-C40/1-NA-DC|113768|2 / 80|
Miniature Circuit Breakers FAZ - RT 15 kA IEC; 10 kA UL/CSA, Characteristic C
|**FAZ-RT**(with Ring Tonque Connection)|SG11905|©|Miniature Circuit Breakers FAZ-RT<br>15 kA IEC; 10 kA UL/CSA, Characteristic C<br>Rated current In(A)<br>Type Designation<br>1-pole<br>0.5<br>1<br>1.5<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>10<br>13<br>15<br>16<br>20<br>25<br>30<br>FAZ-C0,5/1-RT<br>FAZ-C1/1-RT<br>FAZ-C1,5/1-RT<br>FAZ-C2/1-RT<br>FAZ-C3/1-RT<br>FAZ-C4/1-RT<br>FAZ-C5/1-RT<br>FAZ-C6/1-RT<br>FAZ-C7/1-RT<br>FAZ-C8/1-RT<br>FAZ-C10/1-RT<br>FAZ-C13/1-RT<br>FAZ-C15/1-RT<br>FAZ-C16/1-RT<br>FAZ-C20/1-RT<br>FAZ-C25/1-RT<br>FAZ-C30/1-RT|Miniature Circuit Breakers FAZ-RT<br>15 kA IEC; 10 kA UL/CSA, Characteristic C<br>Rated current In(A)<br>Type Designation<br>1-pole<br>0.5<br>1<br>1.5<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>10<br>13<br>15<br>16<br>20<br>25<br>30<br>FAZ-C0,5/1-RT<br>FAZ-C1/1-RT<br>FAZ-C1,5/1-RT<br>FAZ-C2/1-RT<br>FAZ-C3/1-RT<br>FAZ-C4/1-RT<br>FAZ-C5/1-RT<br>FAZ-C6/1-RT<br>FAZ-C7/1-RT<br>FAZ-C8/1-RT<br>FAZ-C10/1-RT<br>FAZ-C13/1-RT<br>FAZ-C15/1-RT<br>FAZ-C16/1-RT<br>FAZ-C20/1-RT<br>FAZ-C25/1-RT<br>FAZ-C30/1-RT|Article No.<br>102117<br>102118<br>102119<br>102120<br>102121<br>102122<br>102123<br>102124<br>102125<br>102126<br>102127<br>102128<br>102129<br>102130<br>102131<br>102132<br>102133|Units per package<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80<br>2 / 80|
|---|---|---|---|---|---|---|
||||32|FAZ-C32/1-RT|102134|2 / 80|
||||35|FAZ-C35/1-RT|102135|2 / 80|
||||40|FAZ-C40/1-RT|102136|2 / 80|
||SG12005||2-pole||||
||a||0.5<br>1<br>1.5|FAZ-C0,5/2-RT<br>FAZ-C1/2-RT<br>FAZ-C1,5/2-RT|102197<br>102198<br>102199|1 / 40<br>1 / 40<br>1 / 40|
||||2|FAZ-C2/2-RT|102200|1 / 40|
||||3|FAZ-C3/2-RT|102201|1 / 40|
||||4|FAZ-C4/2-RT|102202|1 / 40|
||||5|FAZ-C5/2-RT|102203|1 / 40|
||as||6<br>7|FAZ-C6/2-RT<br>FAZ-C7/2-RT|102204<br>102205|1 / 40<br>1 / 40|
||||8|FAZ-C8/2-RT|102206|1 / 40|
||||10|FAZ-C10/2-RT|102207|1 / 40|
||||13|FAZ-C13/2-RT|102208|1 / 40|
||||15|FAZ-C15/2-RT|102209|1 / 40|
||||16|FAZ-C16/2-RT|102210|1 / 40|
||||20|FAZ-C20/2-RT|102211|1 / 40|
||||25|FAZ-C25/2-RT|102212|1 / 40|
||||30|FAZ-C30/2-RT|102213|1 / 40|
||||32|FAZ-C32/2-RT|102214|1 / 40|
||||35|FAZ-C35/2-RT|102215|1 / 40|
||||40|FAZ-C40/2-RT|102216|1 / 40|
||SG12305||3-pole||||
||dg<br>| 77||0.5<br>1<br>1.5<br>2<br>3<br>4|FAZ-C0,5/3-RT<br>FAZ-C1/3-RT<br>FAZ-C1,5/3-RT<br>FAZ-C2/3-RT<br>FAZ-C3/3-RT<br>FAZ-C4/3-RT|102277<br>102278<br>102279<br>102280<br>102281<br>102282|1 / 28<br>1 / 28<br>1 / 28<br>1 / 28<br>1 / 28<br>1 / 28|
||||5|FAZ-C5/3-RT|102283|1 / 28|
||||6|FAZ-C6/3-RT|102284|1 / 28|
||||7|FAZ-C7/3-RT|102285|1 / 28|
||||8|FAZ-C8/3-RT|102286|1 / 28|
||||10|FAZ-C10/3-RT|102287|1 / 28|
||||13|FAZ-C13/3-RT|102288|1 / 28|
||||15|FAZ-C15/3-RT|102289|1 / 28|
||||16|FAZ-C16/3-RT|102290|1 / 28|
||||20|FAZ-C20/3-RT|102291|1 / 28|
||||25|FAZ-C25/3-RT|102292|1 / 28|
||||30|FAZ-C30/3-RT|102293|1 / 28|
||||32|FAZ-C32/3-RT|102294|1 / 28|
||||35|FAZ-C35/3-RT|102295|1 / 28|
||||40|FAZ-C40/3-RT|102296|1 / 28|
9
**==> picture [17 x 234] intentionally omitted <==**
Miniature Circuit Breakers FAZ - RT 15 kA IEC; 10 kA UL/CSA, Characteristic D
**==> picture [480 x 674] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Rated current In (A)|Type Designation|Article No.|Units per package|
|SG11905|1|-|pole|
|0.5|FAZ-D0,5/1-RT|102137|2 / 80|
|1|FAZ-D1/1-RT|102138|2 / 80|
|1.5|FAZ-D1,5/1-RT|102139|2 / 80|
|2|FAZ-D2/1-RT|102140|2 / 80|
|3|FAZ-D3/1-RT|102141|2 / 80|
|4|FAZ-D4/1-RT|102142|2 / 80|
|5|FAZ-D5/1-RT|102143|2 / 80|
|@|6|FAZ-D6/1-RT|102144|2 / 80|
|7|FAZ-D7/1-RT|102145|2 / 80|
|8|FAZ-D8/1-RT|102146|2 / 80|
|10|FAZ-D10/1-RT|102147|2 / 80|
|13|FAZ-D13/1-RT|102148|2 / 80|
|15|FAZ-D15/1-RT|102149|2 / 80|
|16|FAZ-D16/1-RT|102150|2 / 80|
|20|FAZ-D20/1-RT|102151|2 / 80|
|25|FAZ-D25/1-RT|102152|2 / 80|
|30|FAZ-D30/1-RT|102153|2 / 80|
|32|FAZ-D32/1-RT|102154|2 / 80|
|35|FAZ-D35/1-RT|102155|2 / 80|
|40|FAZ-D40/1-RT|102156|2 / 80|
|SG12005|2|-|pole|
|0.5|FAZ-D0,5/2-RT|102217|1 / 40|
|1|FAZ-D1/2-RT|102218|1 / 40|
|1.5|FAZ-D1,5/2-RT|102219|1 / 40|
|2|FAZ-D2/2-RT|102220|1 / 40|
|3|FAZ-D3/2-RT|102221|1 / 40|
|4|FAZ-D4/2-RT|102222|1 / 40|
|5|FAZ-D5/2-RT|102223|1 / 40|
|6|FAZ-D6/2-RT|102224|1 / 40|
|7|FAZ-D7/2-RT|102225|1 / 40|
|8|FAZ-D8/2-RT|102226|1 / 40|
|10|FAZ-D10/2-RT|102227|1 / 40|
|13|FAZ-D13/2-RT|102228|1 / 40|
|15|FAZ-D15/2-RT|102229|1 / 40|
|16|FAZ-D16/2-RT|102230|1 / 40|
|20|FAZ-D20/2-RT|102231|1 / 40|
|25|FAZ-D25/2-RT|102232|1 / 40|
|30|FAZ-D30/2-RT|102233|1 / 40|
|32|FAZ-D32/2-RT|102234|1 / 40|
|35|FAZ-D35/2-RT|102235|1 / 40|
|40|FAZ-D40/2-RT|102236|1 / 40|
|SG12305|3|-|pole|
|0.5|FAZ-D0,5/3-RT|102297|1 / 28|
|1|FAZ-D1/3-RT|102298|1 / 28|
|1.5|FAZ-D1,5/3-RT|102299|1 / 28|
|one|2|FAZ-D2/3-RT|102300|1 / 28|
|3|FAZ-D3/3-RT|102301|1 / 28|
|4|FAZ-D4/3-RT|102302|1 / 28|
|5|FAZ-D5/3-RT|102303|1 / 28|
|6|FAZ-D6/3-RT|102304|1 / 28|
|7|FAZ-D7/3-RT|102305|1 / 28|
|8|FAZ-D8/3-RT|102306|1 / 28|
|10|FAZ-D10/3-RT|102307|1 / 28|
|13|FAZ-D13/3-RT|102308|1 / 28|
|15|FAZ-D15/3-RT|102309|1 / 28|
|16|FAZ-D16/3-RT|102310|1 / 28|
|20|FAZ-D20/3-RT|102311|1 / 28|
|25|FAZ-D25/3-RT|102312|1 / 28|
|30|FAZ-D30/3-RT|102313|1 / 28|
|32|FAZ-D32/3-RT|102314|1 / 28|
|35|FAZ-D35/3-RT|102315|1 / 28|
|40|FAZ-D40/3-RT|102316|1 / 28|
**----- End of picture text -----**<br>
10
**==> picture [595 x 57] intentionally omitted <==**
## Miniature Circuit Breakers FAZ - NA, FAZ - RT
|Accessories:<br>Tripping signal switch for<br>subsequent installation<br>Z-NHK<br>Shunt triprelease<br>FAZ-XAA-NA<br>Busbar-System<br>Z-SV/UL-16/<br> <br>|Connection diagrams<br>1-pole<br>2-pole<br>3-pole|
|---|---|
## Technical Data
|Electrical<br>Design according to<br>UL 489, CSA C22.2 No.5,<br>IEC 60947-2<br>Rated voltage<br>UL/CSA 0.5 - 25 A<br>277/480Y VAC<br>UL/CSA 32 - 40 A<br>240 VAC<br>UL/CSA (per pole)<br>48 VDC<br>IEC<br>240/415 VAC<br>Rated frequency<br>50/60 Hz<br>Rated breaking capacity<br>UL/CSA<br>10 kA<br>IEC<br>15 kA<br>Characteristic<br>C,D<br>Endurance<br>≥20,000 operations<br>Line voltage connection<br>optional suitable for reverse<br>feed<br> <br> <br> <br><br><br> <br> <br><br>|Mechanical|
|---|---|
||Frame size<br>45 mm|
||Device height<br>105 mm|
||Device width<br>17.7 mmperpole|
||Mounting<br>quick fastening with<br>2 lock-in positions on<br>IEC/EN 60715|
||Upper and lower terminals<br>open mouth/lift terminals|
||Terminal capacity<br>1 Wire<br>AWG 18–6<br>2 Wires<br>AWG 18-10|
||Terminal fastening torque<br>AWG 18-21:21 lb-in<br>AWG 10-8: 25 lb-in<br>AWG 6:<br>36 lb-in|
||Mounting<br>independent ofposition|
||Calibration temperature<br>UL 489, CSA C22.2 No.5<br>40°C<br>IEC 60947-2<br>30°C|
## Dimensions (mm)
**==> picture [63 x 104] intentionally omitted <==**
|Power loss at In<br>Characteristic C|Power loss at In<br>Characteristic C|Power loss at In<br>Characteristic C|Power loss at In<br>Characteristic C|
|---|---|---|---|
||**1p**|**2p**|**3p**|
|**In [A]**|**P[W]**|**P[W]**|**P[W]**|
|**0.5**|1.6|3.2|4.7|
|**1**|1.1|2.2|3.4|
|**1.5**|1.3|2.6|3.9|
|**2**|1.4|2.8|4.3|
|**3**|1.2|2.4|3.6|
|**4**|1.4|2.9|4.3|
|**5**|1.9|3.7|5.6|
|**6**|1.2|2.3|3.5|
|**7**|1.4|2.8|4.3|
|**8**|1.4|2.8|4.2|
|**10**|1.8|3.6|5.3|
|**13**|2.4|4.7|7.1|
|**15**|1.9|3.8|5.6|
|**16**|2.1|4.3|6.4|
|**20**|2.9|5.8|8.7|
|**25**|3.1|6.2|9.3|
|**30**|3.0|6.0|9.0|
|**32**|3.4|6.8|10.2|
|**35**|3.7|7.4|11.0|
|**40**|4.0|8.1|12.1|
**==> picture [147 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic D<br>1p 2p 3p<br>In [A] P [W] P [W] P [W]<br>0.5 1.6 3.2 4.8<br>1 0.8 1.5 2.3<br>1.5 1.0 2.1 3.1<br>2 1.0 2.1 3.1<br>3 1.2 2.4 3.6<br>4 1.4 2.9 4.3<br>5 1.5 2.9 4.4<br>6 1.2 2.3 3.5<br>7 1.4 2.8 4.3<br>8 1.2 2.4 3.7<br>10 1.5 3.0 4.5<br>13 2.0 4.1 6.1<br>15 1.5 3.1 4.6<br>16 1.7 3.5 5.2<br>20 1.8 3.7 5.5<br>25 2.6 5.1 7.7<br>30 2.7 5.4 8.1<br>32 3.1 6.2 9.3<br>35 3.8 7.6 11.3<br>40 3.9 7.8 11.6<br>**----- End of picture text -----**<br>
11
## Tripping Characteristics
**==> picture [219 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
7200<br>2<br>3600 1 tripping characteristicacc. to UL 489<br>1200 1 conventional non-tripping current<br>600 Int= 1.0 IN (T=40°C)<br>2 conventional tripping current<br>300 It = 1.35 IN: t < 1 h (T=25°C)<br>120 3 3 2.0 IN: t = 12- 120 s (T=25°C)<br>60<br>30 instantaneous trippingacc. to IEC 60898-1<br>10 3 4 type C: 5 I10 IN: t < 0.1 sN: t > 0.1 s<br>5 6 type D: 10 I N: t > 0.1 s<br>20 IN: t < 0.1 s<br>2<br>1<br>0.5<br>0.2<br>0.1 4 5<br>4 5<br>0.05 C D<br>0.02<br>0.01<br>0.005<br>0.002<br>0.001<br>0.0005<br>1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br>I / I N<br>Tripping time t [sec]<br>**----- End of picture text -----**<br>
**==> picture [88 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Let-through Energy<br>Characteristic C (0.5-20A), 277V<br>**----- End of picture text -----**<br>
**==> picture [110 x 154] intentionally omitted <==**
**==> picture [88 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic D (0.5-20A), 277V<br>**----- End of picture text -----**<br>
**==> picture [111 x 183] intentionally omitted <==**
Influence of ambient temperature T on load carrying capacity
**==> picture [166 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristic C (25-40A), 240V<br>80000<br>70000<br>60000<br>50000<br>40000<br>30000<br>20000<br>15000<br>10000<br>9000<br>8000<br>7000<br>6000<br>5000<br>4000<br>3000<br>2000<br>1500<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>Prospective short-circuit current [A]<br>Characteristic D (25-40A), 240V<br>80000<br>70000<br>60000<br>50000<br>40000<br>30000<br>20000<br>15000<br>10000<br>9000<br>8000<br>7000<br>6000<br>5000<br>4000<br>3000<br>2000<br>1500<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>Prospective short-circuit current [A]<br>C40<br>C35<br>C32<br>C30<br>C25<br>D40<br>D35<br>D32<br>D30<br>D25<br>2<br>2<br>Let-through energy I t [A sec]<br>500 1000 1500 2000 3000 4000 5000 6000 7000 8000 9000 10000<br>2<br>2<br>Let-through energy I t [A sec]<br>500 1000 1500 2000 3000 4000 5000 6000 7000 8000 9000 10000<br>**----- End of picture text -----**<br>
12
## Accessories
**==> picture [483 x 701] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Type Designation|Article No.|Units per package|
|SG12002|SG02008|
|Tripping signal switch|Z-NHK|248434|4 / 120|
|Auxiliary Switch|Z-IHK-NA|113895|2 / 240|
|itLenn|a|hieie,)|
|||iT|1|Ny|Xie|©|Geek|
|ey|: d|
|sg02208|Shunt trip release 110-415VAC|FAZ-XAA-NA110-415VAC|102036|1|
|Shunt trip release 12-110VAC|FAZ-XAA-NA12-110VAC|102037|1|
|i|nati|||®|
|,|int|“>|
|—|2B|
|A.)|be|
|[a|xe|
|_o|
|Description|Type Designation|Article No.|Units per package|
|SG06806|Busbar|block|UL489|(Pin),|Z|-|SV/UL|-|16/|
|=aSear|for FAZ-NA, FAZ-RT|
|tt|#|‘n-t|Sirae|ee|be|7}|ren|•|Do not cut! • Rated current 80 A|16|mm|[2]|
|aTEVWyVTVi|a|ETT|Erere|kK|
|1-phase, 6MU|Z-SV/UL-16/1P-1TE/6|104892|10 / 200|
|1-phase, 12MU|Z-SV/UL-16/1P-1TE/12|104893|10 / 200|
|1-phase, 18MU|Z-SV/UL-16/1P-1TE/18|104894|10 / 40|
|2-phases, 6MU|Z-SV/UL-16/2P-2TE/6|104895|10 / 200|
|2-phases, 12MU|Z-SV/UL-16/2P-2TE/12|104896|10 / 200|
|2-phases, 18MU|Z-SV/UL-16/2P-2TE/18|104897|10 / 40|
|3-phases, 6MU|Z-SV/UL-16/3P-3TE/6|104898|10 / 200|
|3-phases, 12MU|Z-SV/UL-16/3P-3TE/12|104899|10 / 200|
|3-phases, 18MU|Z-SV/UL-16/3P-3TE/18|104900|10 / 40|
|Devices to busbar|Pcs. of the devices|Type|
|1|-p|hase|
|TATA|ACC|
|[9]|x6|Z-SV/UL-16/1P-1TE/6|
|lal|x12|Z|-|SV/UL|-1|6/1P|-|1TE/12|
|=||"|ue|wwWa|ww|M|O|N|E|N|DS|
|ty|ee|
|2|-p|hases|
|‘ste!||__||||x3|Hoo|ee|oY|Z-SV/UL-16/2P-2TE/6|
|{al|lel|x6|Z|-|SV/UL|-|16/2P|-|2TE/12|
|=>]|TAT ATAC AC ACAC|CAA|A|
|TATA|AT|AT ATA ATA|ATA|ATA|ATA|AT|AT|AT|
|3|-p|hases|
|tele|x2|Z-SV/UL-16/3P-3TE/6|
|121|tal|Ta|x4|Z|-|SV/UL|-|16/3P|-|3TE/12|
|e|=/=|Huodduuuud|od|ov|@|
|enn|°|TATA|ATATATA ATA ATA ATATAT|AT ATT|AT|2ET|S|
|Accessories|
|Description|Type Designation|Article No.|Units per package|
|SG07506|
|Extension|Terminal|35|mm|[2]|UL489,|Z|-|EK/35/UL|
|2.5-35mm|[2]|, AWG 14-2|Z-EK/35/UL|104901|3 / 180|
|A|
|SG07706|
|Busbar|Tag|Shrouds|UL489,|ZV|-|BS|-|UL|
|be|»|for 3 pins|ZV-BS-UL|104904|10 / 600|
**----- End of picture text -----**<br>
13
**==> picture [595 x 57] intentionally omitted <==**
## Tripping Signal Switch Z - NHK, Z - IHK - NA
- Design according to IEC/EN 60947-5-1, IEC/EN 62019
- Can be mounted subsequently (screws)
- The specified minimum voltages are per contact Take into account particularly in case of series connection!
- Contact function with relative movement (self-cleaning contacts)
- Contact material and design particularly suitable for extra low voltage
- Z - NHK : The function of one of the two change-over contacts can be switched from “auxiliary switch” to “tripping signal switch”
**==> picture [91 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection diagram<br>Z-NHK Z-IHK-NA<br>**----- End of picture text -----**<br>
**==> picture [40 x 37] intentionally omitted <==**
- Z - IHK - NA : will allow for FAZ-NA > 480Y/277 VAC rating
- Tripping signal contact transmits message of electric tripping, not mechanical switch-off
- Test key for contact function “electrical tripping”
## Technical Data
||Electrical|Z-NHK|Z-IHK-NA|
|---|---|---|---|
||Can be mounted from the left onto|FAZ-NA,FAZ-RT,FAZ-XAA-NA||
||Contact function|2CO|1NO + 1NC|
||Rated voltage|230 V|250 V|
||Frequency|50/60 Hz|50/60 Hz|
||Rated current|2 A|6 A|
||Rated thermal current I~~th~~|2 A|6 A|
||Utilisation category AC13|||
||Rated operational current I~~e~~|3A/250V AC|3A/250V AC|
||Utilisation category AC15|||
||Rated operational current I~~e~~|2A/250V AC|2A/250V AC|
||Utilisation category DC12|||
||Rated operational current Ie|0.5A/110V DC|0.5A/110V DC|
||||0.25A/220V DC|
||Rated insulation voltage U~~I~~|250 V AC|250 V AC|
||Minimum operational voltageper contact U~~min~~|5 V DC|5 V DC|
||Minimum operational current I~~min~~|10 mA DC|10 mA AC/DC|
||Ratedpeak withstand voltage U~~imp ~~(1.2/50µ)|2.5 kV|4 kV|
||Conditional short circuit current Ik|||
||with back-upfuse 6A|1 kA|1 kA|
||Max. back-upfuse,overload and short circuit|6 AgL||
|||||
||Mechanical|||
||Trippingindicator “electrical tripping”|blue/white|-|
||Frame size|45 mm|45 mm|
||Device height|80 mm|80 mm|
||Device width|8.8 mm(0.5MU)|8.8 mm(0.5MU)|
||Mounting|onto switchingdev.||
||Degree ofprotection,built-in|IP40|IP40|
||Terminal protection|finger and hand touch safe|finger and hand touch safe|
|||according to BGV A3,|according to BGV A3,|
|||ÖVE-EN 6|ÖVE-EN 6|
||Terminals|lift terminals|lift terminals|
||Terminal capacity|20-14 AWG|0.5-2.5 mm²|
||Terminal screws|M3(Pozidrive Z0)|M3(Pozidrive Z0)|
||Fasteningtorque of terminal screws|7 lb-in|max. 1.2 Nm|
The voltage of the FAZ-... Circuit Breaker is limited to 300 V with this Auxiliary Switch installed.
**==> picture [88 x 86] intentionally omitted <==**
**==> picture [92 x 82] intentionally omitted <==**
14
**==> picture [595 x 57] intentionally omitted <==**
## Shunt Trip Release FAZ - XAA - NA
- Remote release for subsequent mounting onto FAZ-NA and FAZ-RT
• Module width 1MU
• Additional installation of standard auxiliary switch is possible
- Position indicator red - green
Connection diagram 1 2
## Technical Data
||FAZ-XAA-NA12-110VAC|FAZ-XAA-NA110-415VAC|
|---|---|---|
|Electrical|||
|Can be mounted onto|FAZ-NA,FAZ-RT|FAZ-NA,FAZ-RT|
|Operational voltage range|12-110V AC|110-415V AC|
||12-60V DC|110-230V DC|
|Frequency|50/60 Hz|50/60 Hz|
|Possible standard auxiliaryswitch|Z-NHK|Z-NHK|
||||
|Mechanical|||
|Frame size|45 mm|45 mm|
|Device height|105 mm|105 mm|
|Device width|17.5 mm(1MU)|17.5 mm(1MU)|
|Mounting|quick fasteningwith 2 lock-inpositions on DIN rail EN 50022||
|Degree ofprotection,built-in|IP40|IP40|
|Terminalprotection|finger and hand touch safe accordingto BGV A3,ÖVE-EN 6||
|Terminals|open mouthed/lift|open mouthed/lift|
|Terminal capacity1 and 2 Wires|AWG 18-10|AWG 18-10|
**==> picture [51 x 84] intentionally omitted <==**
15
**==> picture [595 x 57] intentionally omitted <==**
## Busbar Block UL489 (Pin), Z - SV/UL - 16/
## for FAZ-NA, FAZ-RT
- Tested according to UL489
|Ttd di t UL489|||
|---|---|---|
|ese accorng o<br> Do not cut<br> Extension terminal 35 mm2 Z-EK/35/UL for copper conductors<br> For covering of not used pins use busbar tag shrouds ZV-BS-UL|Connection diagram<br>Z-SV/UL-16/3P-3TE<br>Z-SV/UL-16/2P-2TE<br>Z-SV/UL-16/1P-1TE||
|echnical Data|UL489|IEC/EN60947-2|
|ectrical|||
|ated operational voltage|480/277 VAC<br>96 VDC||
|ated frequency|50/60 Hz||
|ated voltage|–|690 VAC|
|vervoltage category|–|III|
|ated impulse withstand voltage U~~imp~~|–|9.5 kV|
|ated current|80 A|80 A|
|ated conditional short-circuit current AC with 350 AgG|–|15 kA|
|hort-circuit current|10 kA|–|
||||
|echanical|||
|usbar cross section|–|16 mm2 Cu|
|ame class acc. to UL94|V0||
|ollution degree|–|2|
|omparative trackingindex|–|CTI 600|
|inimum clearance(intern/extern)|–|> 9.5 / 25.4 mm|
|inimum creepage distance(intern/extern)|–|> 12.7 / 50.8 mm|
|esistance to climatic conditions|–|acc. to DIN/EN60068|
**==> picture [497 x 380] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions (mm)<br>Z-SV/UL-16/.TE/6 Z-SV/UL-16/.TE/12 ZV-BS-UL<br>Z-SV/UL-16/.TE/18 Z-EK/35/UL<br>Busbar Connection Example Z-EK/35/UL<br>UL489 IEC/EN60947 - 2<br># 2-14 AWG 2.5-35 mm [2]<br>60/75°C Cu Cu<br>0.56 in 14 mm<br>tested acc. to Tightening torque<br>of terminal screws<br>UL486A # 14 AWG ≥ 2.3 Nm<br>UL486B # 8-12 AWG ≥ 2.8 Nm<br>UL486E # 6-1 AWG 4 Nm<br>**----- End of picture text -----**<br>
16
**==> picture [595 x 57] intentionally omitted <==**
Lockout Attachment IS/SPE-1TE
**==> picture [130 x 298] intentionally omitted <==**
**----- Start of picture text -----**<br>
LOCK OFF ONLY<br>.35 - .45 Nm 3 mm(1/8")<br>(3 - 4 lb-in)<br>OFF / O<br>5.0 - 7.0 mm Ø<br>(3/16" - 9/32" Ø)<br>MCB UL 489<br>**----- End of picture text -----**<br>
|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|Device Market<br>Current Rating in<br>(A) © 40o C|
|---|---|---|---|---|---|---|---|
|||20o C|25o C|30o C|40o C|50o C|55o C|
|0.5|0.6|0.5|0.5|0.5|0.5|0.5|0.5|
|1.0|1.1|1.1|1.1|1.0|1.0|1.0|0.9|
|1.5|1.7|1.6|1.6|1.6|1.5|1.4|1.4|
|2.0|2.2|2.2|2.1|2.1|2.0|1.9|1.9|
|3.0|3.3|3.2|3.2|3.1|3.0|2.9|2.9|
|4.0|4.4|4.3|4.2|4.2|4.0|3.8|3.8|
|5.0|5.5|5.4|5.3|5.2|5.0|4.8|4.7|
|6.0|6.6|6.5|6.4|6.2|6.0|5.8|5.6|
|7.0|7.7|7.6|7.4|7.3|7.0|6.7|6.6|
|8.0|8.8|8.6|8.5|8.3|8.0|7.7|7.5|
|10.0|11.0|10.8|10.6|10.4|10.0|9.6|9.4|
|13.0|14.3|14.0|13.8|13.5|13.0|12.5|12.5|
|15.0|16.5|16.2|15.9|15.6|15.0|14.4|14.1|
|16.0|17.6|17.3|17.0|16.6|16.0|15.4|15.0|
|20.0|22.0|21.6|21.2|20.8|20.0|19.2|18.8|
|25.0|27.5|27.0|26.5|26.0|25.0|24.0|23.3|
|30.0|33.0|32.4|31.8|31.2|30.0|28.8|28.2|
|32.0|35.2|34.6|33.9|33.3|32.0|30.7|30.1|
|40.0|44.0|43.2|42.4|41.6|40.0|38.4|37.6|
17
## **Moeller Gebäudeautomation GmbH Eugenia 1 A-3943 Schrems**
**E-mail: sales.lowvoltage.systems@moeller.net Internet: www.moeller.at**
© 2008 by Moeller Gebäudeautomation Subject to alterations Printed in Austria (09/08) Layout: SRA Print: Druckerei Rabl, Schrems W0207+0075-7577GB Article No. 104825
Eaton’s electrical business is a global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services.
Eaton’s global electrical brands, including Cutler-Hammer[®] , MGE Office Protection Systems[TM] , Powerware[®] , Holec[®] , MEM[®] , Santak and Moeller, provide customer-driven PowerChain Management[®] solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide.
## **www.eaton.com.**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →