Image not available
Illustrative purposes only
FAZ-C15/2-NA
CIRCUIT BREAKER, THERMAL MAGNETIC, 1P, 2
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Thermal Magnetic Circuit Breakers
- CIRCUIT BREAKER, THERMAL MAGNETIC, 1P, 250V, 15A; Voltage Rating VDC:48V; Voltage Rating VAC:480V; Current Rating:15A; No. of Poles:2; Circuit Breaker Mounting:DIN Rail; Product
- SVHC: No SVHC (17-Dec-2015)
- No. of Poles: 2 Pole
- Product Range: FAZ Series
- Current Rating: 15A
- Voltage Rating VAC: 480VAC
- Voltage Rating VDC: 48VDC
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 69.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - FAZ-C15/2-NA** ## **Miniature circuit breaker (MCB), 15 A, 2p, characteristic: C** **Part no. FAZ-C15/2-NA 102169 EL Number 1691598 (Norway)** |**102169**<br>**EL Number**<br>**(Norway)y)) **<br>**1691598**<br>ole.|||| |---|---|---|---| |**General specifications**|||| |**General specifications**<br>Product name|||Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB| |Part no.|||Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB<br>FAZ-C15/2-NA| |EAN|||4015081020454| |Product Length/Depth|||105 millimetre| |Product height|||75.5 millimetre| |Product width|||35.4 millimetre| |Product weight|||0.243 kilogram| |Compliances|||RoHS conform| |Certifications|||Specially designed for North America, suitable as BCPD<br>CE marking<br>UL 489, CSA C22.2 No. 5<br>CSA-C22.2 No. 5-09<br>UL 489<br>North America (UL listed, CSA certified)<br>IEC 60947-2<br>CSA (File No. 204453)<br>IEC/EN 60947-2<br>UL (File No. E235139)<br>CSA (Class No. 1432-01)<br>UL (Category Control Number DIVQ)<br>IEC 61373<br>EN45545-2| |Product Tradename|||xEffect - FAZ-NA, FAZ-RT| |Product Type|||xEffect - FAZ-NA, FAZ-RT<br>MCB| |Product Sub Type|||None| |**Delivery program**|||| |Application|||Feeder circuits, branch circuits<br>Switchgear for export to North America (UL-listed)| |Number of poles|||Two-pole| |Number of poles (total)|||2| |Number of poles (protected)|||2| |Tripping characteristic|||C| |Release characteristic|||C| |Amperage Rating|||15 A| |Type|||FAZ-NA<br>Miniature circuit breaker| |**Technical Data - Electrical**|||| |Voltage type|||AC| |Voltage rating|||277 V AC / 480 V AC| |Voltage rating at DC|||60 V DC| |Voltage rating (IEC/EN 60947-2)|||440 V| |Voltage rating (UL)|||480Y/277 V| |Rated operational voltage (Ue) - max|||415 V| |Rated insulation voltage (Ui)|||440 V| |Rated impulse withstand voltage (Uimp)|||4 kV| |Frequency rating - min|||50 Hz| |Frequency rating - max|||60 Hz| |Rated switching capacity (IEC/EN 60947-2)|||15 kA| |Breaking capacity|||14 kA (UL489)| |Rated short-circuit breaking capacity (EN 60898) at 230 V|||0 kA| |Rated short-circuit breaking capacity (EN 60898) at 400 V|||0 kA| |Rated short-circuit breaking capacity (IEC 60947-2) at 230 V|||15 kA| |Rated short-circuit breaking capacity (IEC 60947-2) at 400 V|||15 kA| 02/28/2024 Eaton 102169 ED2023 V1.0 EN 1 / 3 Selectivity class Lifespan, electrical Overvoltage category Pollution degree Direction of incoming supply **==> picture [72 x 89] intentionally omitted <==** 3 20000 operations III 2 As required ## **Technical Data - Mechanical** Frame Enclosure width Width in number of modular spacings Built-in depth Mounting width Mounting width per pole Mounting Method Mounting position Degree of protection Frame 45 mm Enclosure width 105 mm Width in number of modular spacings 2 Built-in depth 70.5 mm Mounting width 17.7 mm Mounting width per pole 17.7 mm Mounting Method Top-hat rail IEC/EN 60715 Mounting position As required Degree of protection IP40 (when fitted)IP20 IP20 (IEC) UL/CSA Type: - Terminals (top and bottom) Twin-purpose terminals Connectable conductor cross section (solid-core) - min 1 mm² Connectable conductor cross section (solid-core) - max 25 mm² Connectable conductor cross section (multi-wired) - min 1 mm² Connectable conductor cross section (multi-wired) - max 25 mm² Terminal protection Finger and hand touch safe, DGUV VS3, EN 50274 Tightening torque UL: 2.4 Nm (21 lb-in) for AWG 18 - AWG 12 UL: 4 Nm (36 lb-in) for AWG 6 Max. 2.4 Nm UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8 **Design verification as per IEC/EN 61439 - technical data** Rated operational current for specified heat dissipation (In) 15 A Heat dissipation per pole, current-dependent 0 W Equipment heat dissipation, current-dependent 3.8 W Static heat dissipation, non-current-dependent 0 W Heat dissipation capacity 0 W Ambient operating temperature - min -25 °C Ambient operating temperature - max 75 °C **Design verification as per IEC/EN 61439** 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of assemblies Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must beobserved. ## ## 02/28/2024 Eaton 102169 ED2023 V1.0 EN 2 / 3 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must beobserved. |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |---|---|---|---| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| |**Additional information**|||| |Current limiting class|||3| |Features|||Additional equipment possible| |Functions|||Current limiting circuit breaker| |Special features|||Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of<br>current carrying capacity| |Used with|||FAZ-NA<br>Miniature circuit breaker| ## **Technical data ETIM 9.0** Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss13-27-14-19-01 [AAB905019]) |**Technical data ETIM 9.0**|**Technical data ETIM 9.0**|**Technical data ETIM 9.0**|**Technical data ETIM 9.0**| |---|---|---|---| |Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)|||| |Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss13-27-14-19-01<br>[AAB905019])|||| |Built-in depth||mm|70.5| |Release characteristic|||C| |Number of poles (total)|||2| |Number of protected poles|||2| |Rated current||A|15| |Rated voltage||V|415| |Rated insulation voltage Ui||V|440| |Rated impulse withstand voltage Uimp||kV|4| |Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V||kA|0| |Voltage type|||AC| |Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V||kA|0| |Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V||kA|15| |Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V||kA|15| |Frequency||Hz|50 - 60| |Power loss||W|4| |Current limiting class|||3| |Flush-mounted installation|||No| |Concurrently switching neutral conductor|||No| |Over voltage category|||3| |Pollution degree|||2| |Additional equipment possible|||Yes| |Width in number of modular spacings|||2| |Degree of protection (IP)|||IP20| |Ambient temperature during operating||°C|-25 - 75| |Connectable conductor cross section multi-wired||mm²|1 - 25| |Connectable conductor cross section solid-core||mm²|1 - 25| |Explosion-proof|||No| Eaton Industries GmbH © 04/2023 by Eaton Industries GmbH Eaton 102169 ED2023 V1.0 EN 02/28/2024 3 / 3
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →