**Safety Light Curtain/Safety Multi-Light Beam F3SG-SR/PG**
## **The most advanced light curtain**
- Conforms to major international standards
- Environmental resistance and rugged structure for use in any environment (IP67, IP67G[*][1] )
- Industry’s broadest line-up[*][2] ,
- from finger protection to body protection
- Flexible height model for easy integration into machines and lines
- For diverse applications, from simple protection to data utilization
- *1. IEC 60529/JIS C 0920 Annex 1
- *2. Based on Omron investigation in June 2018.
For the most recent information on models that have been certified for safety standards, refer to your local OMRON website.
## **Table of Contents**
**Model Number Legend ............................................................................................................................................................................... page 2 Ordering Information .................................................................................................................................................................................. page 3 Ratings and Specifications ...................................................................................................................................................................... page 18 List of Models/Response Time/Current Consumption/Weight ............................................................................................................. page 24 Legislation and Standards ....................................................................................................................................................................... page 31 Indicator..................................................................................................................................................................................................... page 32 Connections (Basic Wiring Diagram)...................................................................................................................................................... page 35 Connectable Safety Control Units........................................................................................................................................................... page 44 Input/Output Circuit .................................................................................................................................................................................. page 45 Dimensions................................................................................................................................................................................................ page 47 Troubleshooting........................................................................................................................................................................................ page 64 Related Manuals........................................................................................................................................................................................ page 73**
All items on this datasheet that states "Available soon" will be available in early 2020
**1**
**F3SG-SR/PG**
## **Model Number Legend**
## **Safety Light Curtain F3SG-SR**
## **F3SG-4SR** **-** **-** **-**
(1) (2) (3) (4) (5) (6)
|**No.**|**Classification**|**Code**|**Meaning**|**Remarks**|
|---|---|---|---|---|
|(1)|Type of ESPE|4|Type 4||
|(2)|Function|A|Advanced||
|||B|Standard||
|(3)|Protective height|0160 - 2000|Protective height for finger protection (mm)||
|||0160 - 2480|Protective height for hand protection (mm)||
|||0240 - 1520|Protective height for arm/leg protection (mm)||
|||0280 - 0920|Protective height for body protection (mm)||
|(4)|Detection<br>capability|14|Finger protection (Detection capability: 14-mm dia.)||
|||25|Hand protection (Detection capability: 25-mm dia.)||
|||45|Arm/leg protection (Detection capability: 45-mm dia.)||
|||85|Body protection (Detection capability: 85-mm dia.)||
|(5)|Option 1|Blank|Set of emitter and receiver||
|||L|Emitter||
|||D|Receiver||
|(6)|Option 2|Blank|||
|||F|Flexible height model|Finger protection and hand protection:<br>Protective heights are available in increments<br>of 40 mm up to 1 m|
- **Note: 1.** The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number. Models are not available for all combinations of code numbers. See _Ordering Information_ on page 3 for details.
**2.** The side-mount brackets (intermediate brackets) are included with the safety light curtain.
**3.** Connection cables are not included with the safety light curtain. Order cables sold separately.
## **Safety Multi-Light Beam F3SG-PG**
## **F3SG-4PG A** **-** **-** **-**
(1) (2) (3) (4) (5) (6) (7)
|**No.**|**Classification**|**Code**|**Meaning**|**Remarks**|
|---|---|---|---|---|
|(1)|Type of ESPE|4|Type 4||
|(2)|Function|A|Advanced||
|(3)|Protective height|0580|Protective height (mm)||
|||0880|||
|||0980|||
|||1280|||
|(4)|Number of beams/<br>beam gap|2|2 beams/500 mm|Protective height: 580 mm|
|||3|3 beams/400 mm|Protective height: 880 mm|
|||4|4 beams/300 or 400 mm|Protective height: 980 or 1,280 mm|
|(5)|Application|A|Perimeter access guarding||
|||L|Perimeter guarding long range||
|||C|Perimeter guarding deflect mirror||
|(6)|Option 1|Blank|Set of emitter and receiver or set of emitter/receiver<br>and passive mirror||
|||L|Emitter||
|||D|Receiver||
|||LD|Emitter/receiver|Perimeter guarding deflect mirror only|
|||M|Passive mirror|Perimeter guarding deflect mirror only|
|(7)|Option 2|Blank|||
- **Note: 1.** The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number. Models are not available for all combinations of code numbers.
- See _Ordering Information_ on page 5 for details.
**2.** The side-mount brackets (intermediate brackets) are included with the safety multi-light beam.
**3.** Connection cables are not included with the safety multi-light beam. Order cables sold separately.
**2**
**F3SG-SR/PG Ordering Information**
## **Main Units**
## **Safety Light Curtain**
* Emitters and receivers are available separately. For detail, contact your Omron representative. Example 1) Emitter: F3SG-4SRA0160-14-L, receiver: F3SG-4SRA0160-14-D Example 2) Receiver (flexible height model) only: F3SG-4SRA0200-14-D-F
## **Finger protection (Detection capability: 14-mm dia.)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|**Standard**|
|---|---|---|---|
|||**Model**|**Model**|
|15|160|**F3SG-4SRA0160-14**|**F3SG-4SRB0160-14**|
|19|200|**F3SG-4SRA0200-14-F**|**F3SG-4SRB0200-14-F**|
|23|240|**F3SG-4SRA0240-14**|**F3SG-4SRB0240-14**|
|27|280|**F3SG-4SRA0280-14-F**|**F3SG-4SRB0280-14-F**|
|31|320|**F3SG-4SRA0320-14**|**F3SG-4SRB0320-14**|
|35|360|**F3SG-4SRA0360-14-F**|**F3SG-4SRB0360-14-F**|
|39|400|**F3SG-4SRA0400-14**|**F3SG-4SRB0400-14**|
|43|440|**F3SG-4SRA0440-14-F**|**F3SG-4SRB0440-14-F**|
|47|480|**F3SG-4SRA0480-14**|**F3SG-4SRB0480-14**|
|51|520|**F3SG-4SRA0520-14-F**|**F3SG-4SRB0520-14-F**|
|55|560|**F3SG-4SRA0560-14**|**F3SG-4SRB0560-14**|
|59|600|**F3SG-4SRA0600-14-F**|**F3SG-4SRB0600-14-F**|
|63|640|**F3SG-4SRA0640-14**|**F3SG-4SRB0640-14**|
|67|680|**F3SG-4SRA0680-14-F**|**F3SG-4SRB0680-14-F**|
|71|720|**F3SG-4SRA0720-14-F**|**F3SG-4SRB0720-14-F**|
|75|760|**F3SG-4SRA0760-14-F**|**F3SG-4SRB0760-14-F**|
|79|800|**F3SG-4SRA0800-14**|**F3SG-4SRB0800-14**|
|83|840|**F3SG-4SRA0840-14-F**|**F3SG-4SRB0840-14-F**|
|87|880|**F3SG-4SRA0880-14-F**|**F3SG-4SRB0880-14-F**|
|91|920|**F3SG-4SRA0920-14-F**|**F3SG-4SRB0920-14-F**|
|95|960|**F3SG-4SRA0960-14-F**|**F3SG-4SRB0960-14-F**|
|99|1,000|**F3SG-4SRA1000-14**|**F3SG-4SRB1000-14**|
|119|1,200|**F3SG-4SRA1200-14**|**F3SG-4SRB1200-14**|
|139|1,400|**F3SG-4SRA1400-14**|**F3SG-4SRB1400-14**|
|159|1,600|**F3SG-4SRA1600-14**|**F3SG-4SRB1600-14**|
|179|1,800|**F3SG-4SRA1800-14**|**F3SG-4SRB1800-14**|
|199|2,000|**F3SG-4SRA2000-14**|**F3SG-4SRB2000-14**|
**3**
**F3SG-SR/PG**
## **Hand protection (Detection capability: 25-mm dia.)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|**Standard**|
|---|---|---|---|
|||**Model**|**Model**|
|8|160|**F3SG-4SRA0160-25**|**F3SG-4SRB0160-25**|
|10|200|**F3SG-4SRA0200-25-F**|**F3SG-4SRB0200-25-F**|
|12|240|**F3SG-4SRA0240-25**|**F3SG-4SRB0240-25**|
|14|280|**F3SG-4SRA0280-25-F**|**F3SG-4SRB0280-25-F**|
|16|320|**F3SG-4SRA0320-25**|**F3SG-4SRB0320-25**|
|18|360|**F3SG-4SRA0360-25-F**|**F3SG-4SRB0360-25-F**|
|20|400|**F3SG-4SRA0400-25**|**F3SG-4SRB0400-25**|
|22|440|**F3SG-4SRA0440-25-F**|**F3SG-4SRB0440-25-F**|
|24|480|**F3SG-4SRA0480-25**|**F3SG-4SRB0480-25**|
|26|520|**F3SG-4SRA0520-25-F**|**F3SG-4SRB0520-25-F**|
|28|560|**F3SG-4SRA0560-25**|**F3SG-4SRB0560-25**|
|30|600|**F3SG-4SRA0600-25-F**|**F3SG-4SRB0600-25-F**|
|32|640|**F3SG-4SRA0640-25**|**F3SG-4SRB0640-25**|
|34|680|**F3SG-4SRA0680-25-F**|**F3SG-4SRB0680-25-F**|
|36|720|**F3SG-4SRA0720-25**|**F3SG-4SRB0720-25**|
|38|760|**F3SG-4SRA0760-25-F**|**F3SG-4SRB0760-25-F**|
|40|800|**F3SG-4SRA0800-25**|**F3SG-4SRB0800-25**|
|42|840|**F3SG-4SRA0840-25-F**|**F3SG-4SRB0840-25-F**|
|44|880|**F3SG-4SRA0880-25**|**F3SG-4SRB0880-25**|
|46|920|**F3SG-4SRA0920-25-F**|**F3SG-4SRB0920-25-F**|
|48|960|**F3SG-4SRA0960-25**|**F3SG-4SRB0960-25**|
|50|1,000|**F3SG-4SRA1000-25-F**|**F3SG-4SRB1000-25-F**|
|52|1,040|**F3SG-4SRA1040-25**|**F3SG-4SRB1040-25**|
|56|1,120|**F3SG-4SRA1120-25**|**F3SG-4SRB1120-25**|
|60|1,200|**F3SG-4SRA1200-25**|**F3SG-4SRB1200-25**|
|64|1,280|**F3SG-4SRA1280-25**|**F3SG-4SRB1280-25**|
|68|1,360|**F3SG-4SRA1360-25**|**F3SG-4SRB1360-25**|
|72|1,440|**F3SG-4SRA1440-25**|**F3SG-4SRB1440-25**|
|76|1,520|**F3SG-4SRA1520-25**|**F3SG-4SRB1520-25**|
|80|1,600|**F3SG-4SRA1600-25**|**F3SG-4SRB1600-25**|
|84|1,680|**F3SG-4SRA1680-25**|**F3SG-4SRB1680-25**|
|88|1,760|**F3SG-4SRA1760-25**|**F3SG-4SRB1760-25**|
|92|1,840|**F3SG-4SRA1840-25**|**F3SG-4SRB1840-25**|
|96|1,920|**F3SG-4SRA1920-25**|**F3SG-4SRB1920-25**|
|104|2,080|**F3SG-4SRA2080-25**|**F3SG-4SRB2080-25**|
|114|2,280|**F3SG-4SRA2280-25**|**F3SG-4SRB2280-25**|
|124|2,480|**F3SG-4SRA2480-25**|**F3SG-4SRB2480-25**|
**4**
**F3SG-SR/PG**
**Arm/Leg protection (Detection capability: 45-mm dia.)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|**Standard**|
|---|---|---|---|
|||**Model**|**Model**|
|6|240|**F3SG-4SRA0240-45**|**F3SG-4SRB0240-45**|
|10|400|**F3SG-4SRA0400-45**|**F3SG-4SRB0400-45**|
|14|560|**F3SG-4SRA0560-45**|**F3SG-4SRB0560-45**|
|18|720|**F3SG-4SRA0720-45**|**F3SG-4SRB0720-45**|
|22|880|**F3SG-4SRA0880-45**|**F3SG-4SRB0880-45**|
|30|1,200|**F3SG-4SRA1200-45**|**F3SG-4SRB1200-45**|
|38|1,520|**F3SG-4SRA1520-45**|**F3SG-4SRB1520-45**|
## **Body (Detection capability: 85-mm dia.)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|**Standard**|
|---|---|---|---|
|||**Model**|**Model**|
|4|280|**F3SG-4SRA0280-85**|**F3SG-4SRB0280-85**|
|6|440|**F3SG-4SRA0440-85**|**F3SG-4SRB0440-85**|
|8|600|**F3SG-4SRA0600-85**|**F3SG-4SRB0600-85**|
|10|760|**F3SG-4SRA0760-85**|**F3SG-4SRB0760-85**|
|12|920|**F3SG-4SRA0920-85**|**F3SG-4SRB0920-85**|
## **Safety Multi-Light Beam**
- Emitters and receivers (or emitter/receivers and passive mirrors) are available separately. For detail, contact your Omron representative. Example 1) Emitter: F3SG-4PGA0580-2A-L, receiver: F3SG-4PGA0580-2A-D
Example 2) Emitter/receiver: F3SG-4PGA0880-3C-LD, passive mirror: F3SG-4PGA0880-3C-M
## **Perimeter access guarding (Beam gap: 300 to 500 mm)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|
|---|---|---|
|||**Model**|
|2|580|**F3SG-4PGA0580-2A**|
|3|880|**F3SG-4PGA0880-3A**|
|4|980|**F3SG-4PGA0980-4A**|
|4|1,280|**F3SG-4PGA1280-4A**|
## **Perimeter guarding long range (Beam gap: 300 to 500 mm)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|
|---|---|---|
|||**Model**|
|2|580|**F3SG-4PGA0580-2L**|
|3|880|**F3SG-4PGA0880-3L**|
|4|980|**F3SG-4PGA0980-4L**|
|4|1,280|**F3SG-4PGA1280-4L**|
## **Perimeter guarding deflect mirror (Beam gap: 300 to 500 mm)**
|**Number of beams**|**Protective height**<br>**(mm)**|**Advanced**|
|---|---|---|
|||**Model**|
|2|580|**F3SG-4PGA0580-2C**|
|3|880|**F3SG-4PGA0880-3C**|
|4|980|**F3SG-4PGA0980-4C**|
|4|1,280|**F3SG-4PGA1280-4C**|
**5**
**F3SG-SR/PG**
## **Accessories (Sold separately)**
## **Safety Light Curtain/Safety Multi-Light Beam Mounting Bracket**
The side-mount brackets (intermediate brackets) are included with the light curtain. Order the brackets listed below when angle adjustment is required.
## **For F3SG-SR/PG (except for perimeter guarding deflect mirror)**
The bracket allows beam adjustment after the F3SG-SR/PG (except for perimeter guarding deflect mirror) is mounted on it. Side mounting and backside mounting are possible.
|**Appearance**|**Type**|**Application**|**Model**|
|---|---|---|---|
||Adjustable Side-Mount Bracket<br>(Intermediate Bracket)|The angle adjustment range is ±15°.<br>Two brackets per set (See*1 below for the number of sets<br>required for each model.)|**F39-LSGA**|
||Adjustable Top/Bottom Bracket<br>F3SJ, F3SN Adapter|Use this bracket at the top and bottom positions of the F3SG-<br>SR/PG.<br>The angle adjustment range is ±22.5°.<br>Use this bracket when replacing an existing F3SJ or F3SN<br>Safety Light Curtain.<br>Two brackets per set (See*2 below for the number of sets<br>required for each model.)|**F39-LSGTB-SJ**|
||Adjustable Top/Bottom Bracket<br>F3SG-RA/RE Adapter|Use this bracket at the top and bottom positions of the F3SG-<br>SR/PG.<br>The angle adjustment range is ±22.5°.<br>Use this bracket when replacing an existing F3SG-RA/RE<br>Safety Light Curtain.<br>Two brackets per set (See *2 below for the number of sets<br>required for each model.)|**F39-LSGTB-RE**|
||Adjustable Top/Bottom Bracket<br>MS4800, F3SR Adapter|Use this bracket at the top and bottom positions of the F3SG-<br>SR/PG.<br>The angle adjustment range is ±22.5°.<br>Use this bracket when replacing an existing MS4800 or F3SR<br>Safety Light Curtain.<br>Two brackets per set (See *2 below for the number of sets<br>required for each model.)|**F39-LSGTB-MS**|
- *1. Protective height of 160 to 1440: 2 sets (4 brackets), protective height of 1520 to 2480: 3 sets (6 brackets)
- *2. Using Adjustable Top/Bottom Brackets with Side-Mount Brackets (Intermediate Brackets) or Adjustable Side-Mount Brackets (Intermediate Brackets)
Protective height of 0840 or less:
The Side-Mount Bracket (Intermediate Bracket) or Adjustable Side-Mount Bracket (Intermediate Bracket) is not required. Use 2 sets of Adjustable Top/Bottom Brackets.
Protective height of 0880 to 1680:
Use 2 sets of Adjustable Top/Bottom Brackets and 1 set of Side-Mount Brackets (Intermediate Brackets) or Adjustable Side-Mount Brackets (Intermediate Brackets).
Protective height of 1760 to 2480:
Use 2 sets of Adjustable Top/Bottom Brackets and 2 sets of Side-Mount Brackets (Intermediate Brackets) or Adjustable Side-Mount Brackets (Intermediate Brackets).
Refer to _Dimensions_ on page 47 and following.
## **For F3SG-PG perimeter guarding deflect mirror**
## GD **Available soon**
The bracket allows beam adjustment after the F3SG-PG (perimeter guarding deflect mirror) is mounted on it.
|**Appearance**|**Type**|**Application**|**Model**|
|---|---|---|---|
|---|Adjustable Side-Mount Bracket<br>(Intermediate Bracket) For Deflect<br>Mirror|The angle adjustment range is ±15°.|**F39-LSGA-C**|
|---|Adjustable Top/Bottom Bracket<br>For Deflect Mirror|The angle adjustment range is ±22.5°.|**F39-LSGTB-C**|
**6**
**F3SG-SR/PG**
## **Safety Light Curtain/Safety Multi-Light Beam Connecting Cable Root-Straight Cable**
|**Type**|**Cable length**|**Specifications**<br>~~r~~|
|---|---|---|
|For emitter<br>To sensors: dedicated connector,<br>To external: open-ended type 5 wires<br>Color: Gray<br>(a=|3 m|Brown<br>Black<br>Blue<br>White<br>Yellow<br>IP67 and IP67G (JIS C 0920 Annex 1) rated when mated.<br>24V/0V<br>TEST<br>0V/24V<br>COM(+)<br>OPERATING RANGE SELECT INPUT/COM(-)<br>~~r~~<br>~~-—!~~|
||7 m<br>(a=||
||10 m<br>(a=||
|For receiver or emitter/receiver<br>To sensors: dedicated connector,<br>To external: open-ended type 8 wires<br>Color: Black<br>(a=|3 m<br>(a=|Brown<br>24V/0V<br>Blue<br>0V/24V<br>Black<br>OSSD 1<br>White<br>OSSD 2<br>Yellow<br>RESET/EDM<br>Red<br>AUX<br>Gray<br>MUTE A/PRE-RESET/PSDI/COM(+)<br>Pink<br>MUTE B/COM(-)<br>IP67 and IP67G (JIS C 0920 Annex 1) rated when mated.<br>~~-—!~~|
||7 m<br>(a=||
||10 m<br>(a=||
## **Root-Plug Cable for Extended**
**Appearance Type Cable length Specifications Model** 1 Brown 24V/0V For emitter 2 Black TEST 2 1 To sensors: dedicated connector, To external: M12 connector type (8-pin) 0.3 m 34 BlueWhite 0V/24VCOM(+) 3 5 4 **F39-JGR3K-L** Color: Gray 5 Yellow OPERATING RANGE SELECT INPUT/COM(-) Male IP67 and IP67G (JIS C 0920 Annex 1) rated when mated. 1 Yellow RESET/EDM 2 Brown 24V/0V For receiver or emitter/receiver 3 Gray MUTE A/PRE-RESET/PSDI/COM(+) 2 1 To sensors: dedicated connector, To external: M12 connector type (8-pin) 0.3 m 546 BlackWhitePink OSSD 2OSSD 1MUTE B/COM(-) 34 58 67 **F39-JGR3K-D** Color: Black 7 Blue 0V/24V Male 8 Red AUX IP67 and IP67G (JIS C 0920 Annex 1) rated when mated. e ~~e~~ **Note: 1.** Cables are not included with the safety light curtain/safety multi-light beam. Order the F39-JGC Root-Straight Cable or F39-JGR3K Root-Plug Cable for Extended. **2.** Use with the F39-JGA Extended Socket-Straight Cable or F39-JGB Extended Plug-Socket Cable.
**7**
**F3SG-SR/PG**
**==> picture [138 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extended Socket-Straight Cable<br>**----- End of picture text -----**<br>
**==> picture [530 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
Appearance Type Cable length Specifications Model<br>Connected to root cable or Extended Plug-Socket Cable<br>For emitter 3 m 1 2 12 BrownBlack 24V/0VTEST F39-JG3A-L<br>a M12 connector (5-pin), 5 wires 4 5 3 34 BlueWhite 0V/24VCOM(+) -<br>Color: Gray Female 5 Yellow OPERATING RANGE SELECT INPUT/COM(-)<br>10 m IP67* rated when mated. F39-JG10A-L<br>Connected to root cable or Extended Plug-Socket Cable<br>7 1 Yellow RESET/EDM<br>For receiver or emitter/ 3 m 2 Brown 24V/0V F39-JG3A-D<br>receiverM12 connector (8-pin), 8 wires 76 1 58 243 5346 BlackWhiteGrayPink OSSD 1OSSD 2MUTE B/COM(-)MUTE A/PRE-RESET/PSDI/COM(+)<br>Color: Black 10 m Female 7 Blue 0V/24V F39-JG10A-D<br>8 Red AUX<br>IP67* rated when mated.<br>Ordering Information<br>**----- End of picture text -----**<br>
- When the accessory is used, protect it from cutting oil.
- **Note: 1.** Use with the F39-JGR3K-L/-D Root-Plug Cable for Extended. **2.** To extend the cable length to more than 10 m, connect the F39-JGB Extended Plug-Socket Cable to the F39-JGA Extended SocketStraight Cable.
**Extended Plug-Socket Cable**
**==> picture [487 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
Appearance a Type Cable length Specifications Model<br>3 m Connected to Root-Plug Cable for Connected to Extended Socket-Straight F39-JG3B-L<br>Extended or Extended Plug-Socket Cable Cable or Extended Plug-Socket Cable<br>For emitter ay 1 Brown 1 Brown |<br>1 2 3 Blue 3 Blue 2 1<br>M12 connector (5-pin) on both ends 10 m 4 5 3 24 BlackWhite 24 BlackWhite 3 5 4 F39-JG10B-L<br>Color: Gray == Female 5 Yellow 5 Yellow Male<br>Twisted pair wires are brown and blue, and white and yellow.<br>20 m IP67* rated when mated. F39-JG20B-L<br>Connected to Root-Plug Cable for Connected to Extended Socket-Straight<br>3 m Extended or Extended Plug-Socket Cable Cable or Extended Plug-Socket Cable F39-JG3B-D<br>2 Brown 2 Brown<br>For receiver or emitter/receiverM12 connector (8-pin) on 10 m 76 1 58 2 43 7561 BlueBlackWhiteYellow 7561 BlueBlackWhiteYellow 34 2 58 1 67 F39-JG10B-D<br>both endsColor: Black = Female 83 RedGray 83 RedGray Male<br>4 Pink 4 Pink<br>20 m F39-JG20B-D<br>Twisted pair wires are brown and blue, black and white, yellow and red, and gray and pink.<br>IP67* rated when mated.<br>oo H+} x}<br>**----- End of picture text -----**<br>
- When the accessory is used, protect it from cutting oil.
## **Note: 1.** Use with the F39-JGR3K-L/-D Root-Plug Cable for Extended.
**2.** To extend the cable length to more than 30 m, connect two or more F39-JGB Extended Plug-Socket Cable to the F39-JGA Extended Socket-Straight Cable.
- Example: To extend the cable length to 50 m, connect two F39-JG20B (20 m) Extended Plug-Socket Cables and one F39-JG10A (10 m) Extended Socket-Straight Cable.
**Emitter** F39-JGR3K-L (Gray) F39-JG@B-L (Gray) F39-JG@A-L (Gray)
Extended Extended Root-Plug Cable for Extended Plug-Socket Cable Socket-Straight Cable
**Receiver** F39-JGR3K-D (Black) F39-JG@B-D (Black) F39-JG@A-D (Black)
**8**
**F3SG-SR/PG**
**Side-by-side Cascading Cable (Two cables per set, for emitter and receiver)**
**Appearance Type Cable length Specifications Model** For emitter To sensors: dedicated connector 1, To cascading sensors: dedicated connector 2 Used to series-connect sensors with the Color: Gray 12 cm minimum cable length of 12 cm. **F39-JGR12L** For receiver IP67 and IP67G (JIS C 0920 Annex 1) To sensors: dedicated connector 1, rated when mated. To cascading sensors: dedicated connector 2 Color: Black ~~oo~~ **Note:** To extend the cable length between the series-connected sensors to more than 12 cm, add the F39-JGR3W Cascading Cable for Extended.
## **Cascading Cable for Extended (Two cables per set, for emitter and receiver)**
|**Type**|**Cable length**|**Specifications**|
|---|---|---|
|For emitter<br>To sensors: dedicated connector,<br>To cascading sensors: M12<br>connector type (5 pin)<br>Color: Gray<br>For receiver<br>To sensors: dedicated connector,<br>To cascading sensors: M12<br>connector type (8 pin)<br>Color: Black|0.3 m|Used together with the F39-JGR3K Root-<br>Plug Cable for Extended to extend the<br>cable length between the series-connected<br>sensors to more than 12 cm.<br>IP67 and IP67G (JIS C 0920 Annex 1)<br>rated when mated.|
**Note:** To extend the cable length between the series-connected sensors to more than 60 cm, connect the F39-JGB Extended Plug-Socket Cable (up to 10 m: F39-JG10B) to the F39-JGR3W Cascading Cable for Extended.
Extension cable between sensors: 10 m max. (not including Cascading Cable for Extended (F39-JGR3W) and Root Cable (F39-JGR3K).)
Remove the cap **Emitter** F39-JGR3K-L (Gray) F39-JG **@** B-L (Gray) F39-JGR3W-L (Gray) **Emitter** F39-JGR3K-L (Gray) Root-Plug Cable for Extended Extended Plug-Socket Cable Cascading Cable for Extended Root-Plug Cable for Extended
**Receiver** F39-JGR3K-D (Black) F39-JG **@** B-D (Black) F39-JGR3W-D (Black) **Receiver** F39-JGR3K-D (Black) Remove the cap
**9**
|**Appearance**<br>elm|**Type**<br>elm|**Cable length**<br>elm|**Specifications**<br>elm|**Model**<br>elm|
|---|---|---|---|---|
|>elm|F3SJ-B/A Conversion Cable<br>For emitter<br>To sensor: dedicated connector 1,<br>To wires for F3SJ-B/-A, F3SR or<br>F3SN: M12<br>connector type (8 pin)<br>Color: Gray<br>elm|0.3 m<br>elm|Used to convert the wiring for F3SJ-B/-A,<br>F3SR-B or F3SN Safety Light Curtain to that<br>for the F3SG-SR.<br>elm|**F39-JGR3K-SJ-L**<br>elm|
||F3SJ-B/A Conversion Cable<br>For emitter<br>To sensor: dedicated connector 1,<br>To wires for F3SJ-B/-A, F3SR or<br>F3SN: M12<br>connector type (8 pin)<br>Color: Black<br>elm|||**F39-JGR3K-SJ-D**<br>elm|
||F3SG-RE Conversion Cable<br>For emitter<br>To sensor: dedicated connector 1,<br>To wires for F3SG-RE: M12<br>connector type (4 pin)<br>Color: Gray<br>elm|0.3 m<br>elm|Used to convert the wiring for F3SG-RE Safety<br>Light Curtain to that for the F3SG-SR.<br>elm|**F39-JGR3K-RE-L**<br>elm|
||F3SG-RE Conversion Cable<br>For receiver<br>To sensor: dedicated connector 1,<br>To wires for F3SG-RE: M12<br>connector type (4 pin)<br>Color: Black<br>elm|||**F39-JGR3K-RE-D**<br>elm|
||MS48 Conversion Cable<br>For emitter<br>To sensor: dedicated connector 1,<br>To wires for MS4800: M12<br>connector type (5 pin)<br>Color: Gray<br>elm|0.3 m<br>elm|Used to convert the wiring for MS4800 Safety<br>Light Curtain to that for the F3SG-SR.<br>elm|**F39-JGR3K-MS-L**<br>elm|
||MS48 Conversion Cable<br>For receiver<br>To sensor: dedicated connector 1,<br>To wires for MS4800: M12<br>connector type (8 pin)<br>Color: Black<br>elm|||**F39-JGR3K-MS-D**<br>elm|
Conversion cables are only for PNP connection. To use for NPN, connect the 24 VDC line and the 0 VDC line in reverse. For details, refer to _User's Manual_ . F3SG-SR Emitter F39-JGR3K- **@@** -L(Gray)
F3SG-SR Emitter F39-JGR3K- **@@** -L(Gray) Conversion cable Cables of the existing light curtain ~~ey~~ p F39-JGR3K- ~~e~~ **@@** F3SG-SR Receiver F39-JGR3K- **@@** -D(Black)
**10**
**F3SG-SR/PG**
**Intelligent Tap and Configuration Tool SD Manager 3 Intelligent Tap** *
|**Appearance**|**Type**|**Specifications**|**Model**|
|---|---|---|---|
||Intelligent Tap|Used to configure the F3SG-SR/PG and connect<br>external devices via IO-Link. The F3SG-SR/PG<br>can be configured on a PC or with the DIP switch<br>on the Intelligent Tap.<br>IP67 and IP67G (JIS C 0920 Annex 1) rated when<br>mated.|**F39-SGIT-IL3**|
|-|Bluetooth®Communication Unit|Mounted to the Intelligent Tap to connect with the<br>SD Manager 3 via Bluetooth®.<br>IP67 and IP67G (JIS C 0920 Annex 1) rated when<br>mated.|**F39-SGBT**|
||Intelligent Tap Bracket For DIN in Panel|Bracket to mount the Intelligent Tap on a DIN<br>track.|**F39-LITF1**|
**Note:** Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).
* Use the F39-SGBT Bluetooth[®] Communication Unit or a commercially available USB Type-C[TM] cable to connect to a PC.
## **Configuration tool SD Manager 3**
|**Type**|**Specifications**|
|---|---|
|SD Manager 3|Configuration tool running on a PC.<br>Use with the Intelligent Tap. (The Bluetooth®communication unit is required to connect using Bluetooth®.)<br>For details, refer to your local Omron website.|
|SD Manager 3 Mobile APP|Monitoring tool running on a smartphone and tablet.<br>Use with the Intelligent Tap and Bluetooth®communication unit.<br>For details, refer to your local Omron website.|
## **Intelligent Tap-to-IO-Link Master Cable**
|**Omron IO-Link**<br>**master unit**|**Type**<br>~~|~~|**Cable length**|**Specifications**<br>CEE|**Model**|
|---|---|---|---|---|
|NX-ILM400|Single-ended cable<br>M12 connector (5-pin), 5 wires<br>Color: Gray<br>~~|~~<br>=|2 m<br>=O|5<br>3<br>2<br>1<br>4<br>1<br>2<br>3<br>4<br>5<br>L+<br>DO<br>L-<br>C/Q<br>Not used<br>Brown<br>White<br>Blue<br>Black<br>Yellow<br>Female<br>IP67*rated when mated.<br>CEE<br>O~~EESE~~R|**XS5F-D521-DJ0-IL**|
|GX-ILM08C|Double-ended cable<br>M12 connector (5-pin), 5 wires<br>Color: Gray<br>~~|~~<br>=|3 m<br>=O|1<br>3<br>2<br>4<br>5<br>5<br>3<br>2<br>1<br>4<br>1<br>3<br>2<br>4<br>5<br>5<br>4<br>1<br>2<br>3<br>Female<br>IP67*rated when mated.<br>Male<br>Brown<br>Black<br>Blue<br>White<br>Yellow<br>Brown<br>Black<br>Blue<br>White<br>Yellow<br>CEE<br>O~~EESE~~R|**F39-JG3B-L**|
|||10 m<br>=O||**F39-JG10B-L**|
|||20 m<br>=O<br>—||**F39-JG20B-L**|
**==> picture [392 x 75] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extended XS5F-D521-DJ0-IL (Gray)/<br>Root-Plug Cable for Extended Plug-Socket Cable CN4 CN3 F39-JG@B-L (Gray)<br>IO-Link Master<br>OSSD<br>ck Receiver F39-JGR3K-D (Black) F39-JG@B-D (Black) CN1 im CN2 —_— F39-JGF39-JG ——— @@A-D (Black)/B-D (Black)<br>Intelligent Tap<br>F39-SGIT-IL3<br>**----- End of picture text -----**<br>
**11**
**F3SG-SR/PG**
:
## **Reduced Wiring System**
## **Y-Joint Plug/Socket Connector**
**==> picture [456 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Appearance Type Cable length Specifications Model<br>F3SG-SR/PG<br>Emitter Receiver<br>Root-Plug Cable for ExtendedF39-JGR3K-L (Gray) *2 Root-Plug Cable for ExtendedF39-JGR3K-D (Black) *2<br>M12 connectors.<br>Used for reduced wiring. 0.5 m Y-Joint Plug/ F39-GCNY2<br>IP67 *1 rated when mated. Socket Connector for Advanced type<br>F39-GCNY2<br>Extended<br>Plug-Socket CableF39-JG@B-L (Gray) *2<br>Extended<br>Socket-Straight CableF39-JG@A-D (Black) *2<br>LL<br>**----- End of picture text -----**<br>
- *1. When the accessory is used, protect it from cutting oil.
- *2. Order the cable (root-plug cable for extended and extended cable) for emitter (end of model: -L) and the cable for receiver (end of model: -D).
## **Reset Switch Connector**
**==> picture [456 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
Appearance a Type Cable length Specifications Model<br>F3SG-SR/PG<br>Receiver or emitter/receiver<br>Root-Plug Cable for<br>Extended<br>’ F39-JGR3K-D (Black) *2<br>M12 connectors.<br>Reset Switch<br>Used for reduced wiring. 0.5 m Connector F39-GCNY3<br>IP67 *1 rated when mated. F39-GCNY3<br>Extended<br>XS5F-D421@80-F Socket-Straight Cable<br>F39-JG@A-D (Black) *2<br>JL<br>Connect to<br>a reset switch (NC contact)<br>**----- End of picture text -----**<br>
**Note:** The customer needs to prepare a reset switch (NC contact).
- *1. When the accessory is used, protect it from cutting oil.
- *2. Order the extended socket-straight cable for receiver (end of model: -D).
## **Reset Switch Connector-to-Reset Switch Cable**
Connector Connected to Cable, Socket on One Cable End
|**Appearance**|**Type**|**Cable length**|**Specifications**|**Model**|
|---|---|---|---|---|
||M12 connector (4-pin), 4<br>wires|1 m|Brown<br>White<br>Blue<br>Black<br>24V/0V<br>RESET<br>0V/24V<br>AUX<br>1<br>2<br>3<br>4<br>Female<br>IP67*rated when mated.<br>3<br>2<br>1<br>4|**XS5F-D421-C80-F**|
|||2 m||**XS5F-D421-D80-F**|
|||3 m||**XS5F-D421-E80-F**|
|||5 m||**XS5F-D421-G80-F**|
|||10 m||**XS5F-D421-J80-F**|
|||20 m<br>|||**XS5F-D421-L80-F**|
- When the accessory is used, protect it from cutting oil.
**12**
**F3SG-SR/PG**
## **Muting System** GD **Available soon**
**Muting Sensor Arm Mounter (Two mounters per set, for emitter and receiver)**
|**Note: 1.** The muting sensor and reflector are sold separately.<br>**Appearance**<br>**Application**<br>**Length**<br>**Model**<br>The through-beam muting sensor can be mounted easily.<br>150 mm<br>**F39-FMA150T**<br>400 mm<br>**F39-FMA400T**<br>The retroreflective muting sensor can be mounted easily.<br>150 mm<br>**F39-FMA150R**<br>400 mm<br>**F39-FMA400R**<br>~~aa~~|
|---|
## **Note: 1.** The muting sensor and reflector are sold separately.
**2.** When mounting the muting sensor arm mounter to the safety light curtain, order the F39-LMAF Muting Sensor Arm Mounter Bracket for SLC. When the muting sensor arm mounter is mounted to the floor mount column, no brackets are required.
## **Muting Sensor Arm Mounter Bracket for SLC (Two brackets per set, for emitter and receiver) ***
|**Appearance**|**Application**|**Model**|
|---|---|---|
||For F3SG-SR/PG (except for perimeter guarding deflect mirror)|**F39-LMAF1**|
|**---**|||
||For F3SG-PG perimeter guarding deflect mirror|**F39-LMAF2**|
- Order when mounting the muting sensor arm mounter to the safety light curtain. When the muting sensor arm mounter is mounted to the floor mount column, no brackets are required.
## **Muting Sensor**
|**Mounter**<br>a|**Sensing method**<br>a|**Sensing distance**|**Output type**|**Model**|
|---|---|---|---|---|
|F39-FMAT<br>a|Through-beam<br>a<br>~~ee~~|10 m<br>|NPN output<br>|**E3Z-T66A**|
||||PNP output<br>|**E3Z-T86A**|
|F39-FMAR|Retro-reflective*1<br>~~e~~|4 m*2<br>~~e~~w|NPN output<br>w|**E3Z-R66**|
||||PNP output<br>w|**E3Z-R86**|
||||Reflectors<br>w|**E39-R1S**|
- *1. The reflector is not included with the muting sensor. Order the E39-R1S Reflector when using the E3Z-R6 Retroreflective Muting Sensor.
- *2. The minimum required distance between the E3Z Muting Sensor and reflector is 100 mm. For details, refer to your local Omron website.
**13**
**F3SG-SR/PG**
.
## **Muting Sensor Connection Box**
**==> picture [498 x 648] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cable<br>Appearance Application Specifications Model<br>Length<br>PNP/NPN selection<br>Main Unit: M12 socket (5 pin) ×7,<br>Speeds up wiring muting sensors. M12 socket (8 pin) ×1 0.5 m F39-GCN5<br>Cable: M12 plug (8 pin) ×1<br>IP67 * rated when mated.<br>eS<br>Connectors connected to cable,<br>Cable to connect the E3Z Muting Sensor and M8 socket and M12 plug on cable 0.2 m XS3W-M42C-4C2-A<br>F39-GCN5 Muting Sensor Connection Box.<br>ends (4 pin)<br>1 m XS5W-D421-C81-F<br>2 m XS5W-D421-D81-F<br>Used together with the XS3W-M42C-4C2-A to<br>extend the cable length between the E2Z Connectors connected to cable, 3 m XS5W-D421-E81-F<br>M12 socket and M12 plug on cable<br>Muting Sensor and muting sensor connection box to more than 0.2 m. ends (4 pin) 5 m XS5W-D421-G81-F<br>10 m XS5W-D421-J81-F<br>20 m XS5W-D421-L81-F<br>When the accessory is used, protect it from cutting oil.<br>Select the same output type for both the safety light curtain/safety multi-light beam (PNP/NPN selection by wiring) and muting sensor<br>(PNP or NPN model).<br>2. For details of the XS3W and XS5W, refer to your local OMRON website.<br>3. Use the F39-JGB-D Extended Plug-Socket Cable to connect the muting sensor connection box with the Intelligent Tap.<br>The connection example for optical synchronization is shown below.<br><Connection example> Emitter Receiver<br>Muting sensors Muting sensors<br>E3Z Root-Plug Cable E3Z<br>(Retro-reflective) for Extended (Retro-reflective)<br>F39-JGR3K-L<br>A1 B1 (Gray) B2 A2<br>F39-JGR3K-D<br>(Black)<br>L J LJ | | L J LJ<br>XS3W-M42C-4C2-A<br>Extended<br>Plug-Socket Cable<br>F39-JG@B-L<br>(Gray)<br>F39-JG@B-D<br>TL (Black) AUX<br>XS5H-D421-@80-F<br>CN4 CN3<br>XS5W-D421-@81-F<br>CN1 CN2<br>Intelligent Tap F39-JG@B-D<br>F39-SGIT-IL3 (Black)<br>8 6 4 2<br>7 5 3 1<br>ra<br>XS5H-D521-@G0-A<br>n n<br>U<br>RESET<br>**----- End of picture text -----**<br>
- When the accessory is used, protect it from cutting oil.
- **Note: 1.** Select the same output type for both the safety light curtain/safety multi-light beam (PNP/NPN selection by wiring) and muting sensor (PNP or NPN model).
**14**
**F3SG-SR/PG**
**Floor Mount System Floor Mount Column**
|**Mirror Column (for F3SG-SR Safety Light Curtain)**<br>**Appearance**<br>**Protective height of safety light curtain**<br>**Column height**<br>**Model**<br>**Safety light curtain**<br>**Safety multi-light beam**<br>Up to 0880<br>0580<br>990 mm<br>**F39-ST0990**<br>Up to 1280<br>0880, 0980<br>1,310 mm<br>**F39-ST1310**<br>Up to 1520<br>1280<br>1,630 mm<br>**F39-ST1630**<br>Up to 1840<br>---<br>1,950 mm<br>**F39-ST1950**<br>Up to 2080<br>---<br>2,270 mm<br>**F39-ST2270**<br>**Appearance**<br>**Protective height of safety light curtain**<br>**Column height**<br>**Model**<br>Up to 0800<br>990 mm<br>**F39-SML0990**<br>Up to 1120<br>1,310 mm<br>**F39-SML1310**<br>Up to 1440<br>1,630 mm<br>**F39-SML1630**<br>Up to 1760<br>1,950 mm<br>**F39-SML1950**<br>Up to 2080<br>2,270 mm<br>**F39-SML2270**<br>—~~—-—~~|
|---|
|**Note:**The F3SG-SR Safety Light Curtain with the protective height of 2280 or more cannot be used.|
|**Mirror Column For Multiple Beam (for F3SG-PG Safety Multi-Light Beam)**|
|**Mount-Column Adjustable Base**<br>**Appearance**<br>**Safety Multi-Light Beam**<br>**Column height**<br>**Model**<br>F3SG-4PG0580-2<br>990 mm<br>**F39-PML0990-2**<br>F3SG-4PG0880-3A/3L<br>1,310 mm<br>**F39-PML1310-3**<br>F3SG-4PG0980-4<br>**F39-PML1310-4**<br>F3SG-4PG1280-4<br>1,630 mm<br>**F39-PML1630-4**<br>**Appearance**<br>**Application**<br>**Model**<br>Mounted to the floor mount column or mirror column.<br>The angle and height of the column can be adjusted.<br>**F39-STB**<br>~~———~~<br>~~.~~|
**15**
**F3SG-SR/PG**
**Laser Alignment Pointer**
**Appearance Specifications Model** The laser alignment pointer is attached on the optical surface of the F3SG-SR/PG to help coarse adjustment of beams. * **F39-PTG** ~~=»~~
|* Cannot be mounted on the passive mirror.<br>**Lamp**<br>**Available soon**|
|---|
|* When the accessory is used, protect it from cutting oil.<br>**Note:**The Lamp does not support Bluetooth®communication.<br>**Appearance**<br>**Specifications**<br>**Model**<br>The lamp can be connected to emitter, receiver, or emitter/receiver and turned ON based on<br>the operation of F3SG-SR/PG.<br>The lamp can indicate red, orange, and green colors, to which three different states can be<br>assigned.<br>IP67*rated when mated.<br>**F39-SGLP**<br>(|
**Test Rod** *
**Diameter Model** 14 mm dia. **STI-TO14(42800-0240)** ~~——————~~ 25 mm dia. **STI-TO24(42800-0260)**
* The customer needs to prepare a test rod lager than 25-mm dia.
**16**
**F3SG-SR/PG**
|**Safety light curtain**<br>~~PT~~|**Safety light curtain**<br>~~PT~~|**Safety light curtain**<br>~~PT~~|
|---|---|---|
|**Finger protection**<br>~~PT~~<br>~~a~~|**Hand protection**<br>~~PT~~<br>C|**Arm/leg protection**<br>~~PT~~<br>C|
|F3SG-4SR0160-14<br>a|F3SG-4SR0160-25|---|
|F3SG-4SR0240-14<br>a<br>~~en~~|F3SG-4SR0240-25<br>~~en~~|F3SG-4SR0240-45<br>~~en~~|
|F3SG-4SR0320-14<br>~~en~~<br>~~en~~|F3SG-4SR0320-25<br>~~en~~<br>~~en~~|---<br>~~en~~<br>~~en~~|
|F3SG-4SR0400-14<br>~~en~~<br>en|F3SG-4SR0400-25<br>~~en~~<br>en|F3SG-4SR0400-45<br>~~en~~<br>en|
|F3SG-4SR0480-14<br>en<br>en|F3SG-4SR0480-25<br>en<br>en|---<br>en<br>en|
|F3SG-4SR0560-14<br>en<br>en|F3SG-4SR0560-25<br>en<br>en|F3SG-4SR0560-45<br>en<br>en|
|F3SG-4SR0640-14<br>en<br>en|F3SG-4SR0640-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR0720-25<br>en<br>en|F3SG-4SR0720-45<br>en<br>en|
|F3SG-4SR0800-14<br>en<br>en|F3SG-4SR0800-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR0880-25<br>en<br>en|F3SG-4SR0880-45<br>en<br>en|
|F3SG-4SR0960-14-F<br>en<br>en|F3SG-4SR0960-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>a|F3SG-4SR1040-25<br>en|---<br>en|
|---<br>a<br>en|F3SG-4SR1120-25<br>en|---<br>en|
|F3SG-4SR1200-14<br>en<br>en|F3SG-4SR1200-25<br>en<br>en|F3SG-4SR1200-45<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1280-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1360-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1440-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1520-25<br>en<br>en|F3SG-4SR1520-45<br>en<br>en|
|F3SG-4SR1600-14<br>en<br>en|F3SG-4SR1600-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1680-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1760-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>en|F3SG-4SR1840-25<br>en<br>en|---<br>en<br>en|
|---<br>en<br>a|F3SG-4SR1920-25<br>en<br>G|---<br>en<br>G|
## **Spatter Protection Cover (2 covers per set, one for emitter and one for receiver)**
- **Note: 1.** The operating range of the safety light curtain attached with the spatter protection cover is 10% shorter than the rating. **2.** Two or more spatter protection covers can be attached to the safety light curtain with a protective height not listed above. The F39-HSG0360 is also available for use together with other spatter protection covers.
**17**
**F3SG-SR/PG**
## **Ratings and Specifications**
## **Safety Light Curtain F3SG-SR Series Main unit**
The in the model names indicate the protective heights in millimeters.
||**Model**|**Model**|**Model**|**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**25**<br>**F3SG-****SRB****-**<br>**25**|**F3SG-****SRA****-**<br>**45**<br>**F3SG-****SRB****-**<br>**45**|**F3SG-****SRA****-**<br>**85**<br>**F3SG-****SRB****-**<br>**85**|
|---|---|---|---|---|---|---|---|---|
|**Performance**|**Object resolution**<br>**(Detection capability)**|||Opaque objects|||||
|||||14-mm dia.||25-mm dia.|45-mm dia.|85-mm dia.|
||**Beam gap**|||10 mm||20 mm|40 mm|80 mm|
||**Number of beams**|||15 to 199||8 to 124|6 to 38|4 to 12|
||**Lens size**|||4.43.4 mm (WH)||6.74.5 mm (WH)|||
||**Protective height**|||160 to 2,000 mm||160 to 2,480 mm|240 to 1,520 mm|280 to 920 mm|
||**Operating range**|**Long**||0.3 to 10.0 m*||0.3 to 20.0 m|||
|||**Short**||0.3 to 3.0 m*||0.3 to 7.0 m|||
|||* When operating at an ambient temperature of -10 to -30°C, use the F3SG-SR with the operating range of 0.3 to 5.0 m in Long<br>Mode and 0.3 to 1.5 m in Short Mode.|||||||
||**Response time**<br>***1**|**Normal**<br>**mode**|**ON to**<br>**OFF**|Optical synchronization:<br>8 to 18 ms<br>Wired synchronization:<br>10 to 21 ms||Optical synchronization:<br>8 to 13 ms<br>Wired synchronization:<br>10 to 17 ms|Optical synchronization: 8 ms<br>Wired synchronization: 10 ms||
||||**OFF to**<br>**ON**|Optical synchronization:<br>40 to 90 ms<br>Wired synchronization:<br>50 to 105 ms||Optical synchronization:<br>40 to 65 ms<br>Wired synchronization:<br>50 to 85 ms|Optical synchronization: 40 ms<br>Wired synchronization: 50 ms||
|||**×2 Slow**<br>**mode*2**|**ON to**<br>**OFF**|Optical synchronization:<br>16 to 36 ms<br>Wired synchronization:<br>20 to 42 ms||Optical synchronization:<br>16 to 26 ms<br>Wired synchronization:<br>20 to 34 ms|Optical synchronization: 16 ms<br>Wired synchronization: 20 ms||
||||**OFF to**<br>**ON**|Optical synchronization:<br>80 to 180 ms<br>Wired synchronization:<br>100 to 210 ms||Optical synchronization:<br>80 to 130 ms<br>Wired synchronization:<br>100 to 170 ms|Optical synchronization: 80 ms<br>Wired synchronization: 100 ms||
|||**×4 Slow**<br>**mode*2**|**ON to**<br>**OFF**|Optical synchronization:<br>32 to 72 ms<br>Wired synchronization:<br>40 to 84 ms||Optical synchronization:<br>32 to 52 ms<br>Wired synchronization:<br>40 to 68 ms|Optical synchronization: 32 ms<br>Wired synchronization: 40 ms||
||||**OFF to**<br>**ON**|Optical synchronization:<br>160 to 360 ms<br>Wired synchronization:<br>200 to 420 ms||Optical synchronization:<br>160 to 260 ms<br>Wired synchronization:<br>200 to 340 ms|Optical synchronization: 160 ms<br>Wired synchronization: 200 ms||
|||**×8 Slow**<br>**mode*2**|**ON to**<br>**OFF**|Optical synchronization:<br>64 to 144 ms<br>Wired synchronization:<br>80 to 168 ms||Optical synchronization:<br>64 to 104 ms<br>Wired synchronization:<br>80 to 136 ms|Optical synchronization: 64 ms<br>Wired synchronization: 80 ms||
||||**OFF to**<br>**ON**|Optical synchronization:<br>320 to 720 ms<br>Wired synchronization:<br>400 to 840 ms||Optical synchronization:<br>320 to 520 ms<br>Wired synchronization:<br>400 to 680 ms|Optical synchronization: 320 ms<br>Wired synchronization: 400 ms||
|||*1. Response time when used in one segment system.<br>Refer to page 24. Refer to_the User's Manual_for cascaded connection.<br>*2. Selectable by SD Manager 3.|||||||
||**Effective**<br>**aperture angle**<br>**(EAA)**<br>**(IEC 61496-2)**|**Type 4**||±2.5° max.*|||||
|||* Emitter and receiver at operating range of 3 m or greater.|||||||
||**Light source**|||Infrared LEDs, Wavelength: 870 nm|||||
||**Startup waiting time**|||3 s max.|||||
|**Electrical**|**Power supply voltage (Vs)**|||SELV/PELV 24 VDC±20% (ripple p-p 10% max.)|||||
||**Current consumption**||||Refer to page 24||||
||**Safety outputs (OSSD)**|||Two PNP or NPN transistor outputs (PNP or NPN is selectable by wiring of power supply.)<br>Load current: 300 mA max., Residual voltage: 2 V max. (except for voltage drop due to cable extension),<br>Capacitive load: 1F max., Inductive load: 2.2 H max.*1*2*3<br>Leakage current: 1 mA max.(PNP), 2 mA max.(NPN)*4<br>*1. For the F3SG-SRA, the load current is 150 mA max. in 2-segment cascade and 80 mA max. in 3-<br>segment cascade.<br>*2. The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.<br>*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF.<br>When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.<br>*4. These values must be taken into consideration when connecting elements including a capacitive load<br>such as a capacitor.|||||
||**Auxiliary output**|||One PNP or NPN transistor output (PNP or NPN is selectable by wiring of power supply.)<br>Load current: 100 mA max., Residual voltage: 2 V max.*<br>* The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.|||||
||**Output operation**<br>**mode**|**Safety output**||Light-ON (Safety outputs are turned to the ON state when the receiver receives an emitting signal.)|||||
|||**Auxiliary output**||Safety output (Inverted signal output: Enable) (default) (Configurable by SD Manager 3)|||||
**18**
**F3SG-SR/PG**
||**Model**||**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**25**<br>**F3SG-****SRB****-**<br>**25**|**F3SG-****SRA****-**<br>**45**<br>**F3SG-****SRB****-**<br>**45**|**F3SG-****SRA****-**<br>**85**<br>**F3SG-****SRB****-**<br>**85**|
|---|---|---|---|---|---|---|---|
|**Electrical**|**Input voltage**|**TEST**|Light emission stops when connected to 24 V DC<br>ON voltage:<br>Vs-3 V to Vs (short circuit current: approx. 5.0 mA)*<br>OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA)*<br>Light emission stops when connected to 0 V<br>ON voltage:<br>0 to 3 V (short circuit current: approx. 6.0 mA)<br>OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA)*|||||
|||**OPERATING**<br>**RANGE SELECT**<br>**INPUT**|Long: 12 V to Vs (short circuit current: approx. 4.2 mA)*or open<br>Short: 0 to 3 V (short circuit current: approx. 4.2 mA)|||||
|||**RESET/EDM**|PNP ON voltage:<br>Vs-3 V to Vs (short circuit current: approx. 9.5 mA)*<br>OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA)*<br>NPN ON voltage:<br>0 to 3 V (short circuit current: approx. 13.0 mA)<br>OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA)*|||||
|||**MUTE A/B,**<br>**RE-RESET, PSDI**|PNP ON voltage:<br>Vs-3 V to Vs (short circuit current: approx. 4.5 mA)*<br>OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA)*<br>NPN ON voltage:<br>0 to 3 V (short circuit current: approx. 7.0 mA)<br>OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA)*|||||
|||* The Vs indicates a supply voltage value in your environment.||||||
||**Overvoltage category (IEC 60664-1)**||II|||||
||**Indicators**|||Refer to page 32||||
||**Protective circuit**||Output short-circuit protection|||||
||**Insulation resistance**||20 Mor higher (500 VDC megger)|||||
||**Dielectric strength**||1,000 VAC, 50/60 Hz (1 min)|||||
|**Functional**|**Mutual interference prevention**||Optical synchronization by Scan Code: in up to 2 sets<br>Wired synchronization: in up to 3 sets|||||
||**Cascade connection**||Number of cascaded segments: 3 max.<br>Total number of beams: 255 max.|||||
||**Test function**||Self-test (at power-on, and during operation)<br>External test (light emission stop function by test input)|||||
||**Safety-related functions**||Interlock<br>External Device Monitoring (EDM)<br>Pre-Reset<br>PSDI<br>Fixed Blanking/Floating Blanking<br>Reduced Resolution<br>Muting/Override<br>Mutual Interference Prevention<br>PNP/NPN Selection<br>Response Time Adjustment|||||
|**Environmental**|**Ambient**<br>**temperature**|**Operating**|-30 to 55 °C (non-icing)|||||
|||**Storage**|-30 to 70 °C|||||
||**Ambient**<br>**humidity**|**Operating**|35% to 85% (non-condensing)|||||
|||**Storage**|35% to 95%|||||
||**Ambient illuminance**||Incandescent lamp: 3,000 Ix max. on receiver surface<br>Sunlight: 10,000 Ix max. on receiver surface|||||
||**Degree of protection (IEC 60529)**||IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G|||||
||**Vibration resistance (IEC 61496-1)**||10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes|||||
||**Shock resistance (IEC 61496-1)**||100 m/s2, 1000 shocks for all 3 axes|||||
||**Pollution degree (IEC 60664-1)**||3|||||
|**Connections**|**Root cable**|**Type of**<br>**connection**|To sensors: dedicated connector, To external: M12 connector type (5-pin emitter and 8-pin receiver) or<br>open-ended type<br>IP67 and IP67G (JIS C 0920 Annex 1)*rated when mated.<br>* The F3SG-SR meets the degree of protection when the root cable is correctly connected with the F3SG-<br>SR. The degree of protection is not satisfied with the part where cable wires are uncovered.|||||
|||**Number of wires**|Emitter: 5, Receiver: 8|||||
|||**Cable length**||Refer to page 7||||
|||**Cable diameter**|6 mm|||||
|||**Minimum bending**<br>**radius**|R5 mm|||||
||**Cascading cable**|**Type of**<br>**connection**|To sensors: dedicated connector, To cascading sensors: M12 connector type (5-pin emitter and 8-pin<br>receiver) or dedicated connector<br>IP67 and IP67G (JIS C 0920 Annex 1)*rated when mated.<br>* The F3SG-SR meets the degree of protection when the cascading cable is correctly connected with the<br>F3SG-SR and the root cable.|||||
|||**Number of wires**|Emitter: 5, Receiver: 8|||||
|||**Cable length**||Refer to page 9||||
|||**Cable diameter**|6 mm|||||
|||**Minimum bending**<br>**radius**|R5 mm|||||
**19**
**F3SG-SR/PG**
||**Model**|||**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**14**<br>**F3SG-****SRB****-**<br>**14**|**F3SG-****SRA****-**<br>**25**<br>**F3SG-****SRB****-**<br>**25**|**F3SG-****SRA****-**<br>**45**<br>**F3SG-****SRB****-**<br>**45**|**F3SG-****SRA****-**<br>**85**<br>**F3SG-****SRB****-**<br>**85**|
|---|---|---|---|---|---|---|---|---|
|**Connections**|**Extension cable**<br>**- Extended**<br>**Socket-Straight**<br>**Cable**<br>**- Extended Plug-**<br>**Socket Cable**|**Type of**<br>**connection**||M12 connector type (5-pin emitter and 8-pin receiver), IP67*rated when mated<br>* The extension cable meets the degree of protection when the root cable is correctly connected with the<br>extension cable. The degree of protection is not satisfied with the part where cable wires are uncovered.|||||
|||<br>**Number of wires**||Emitter: 5, Receiver: 8|||||
|||<br>**Cable length**|||Refer to page 8||||
|||**Cable diameter**||6.6 mm|||||
|||**Minimum bending**<br>**radius**||R36 mm|||||
||**Cable extension**||Refer to page 21 for restrictions on cable extension.||||||
|||**Root cable**||In optical synchronization: 100 m max.*between power supply and emitter and between power supply<br>and receiver<br>In wired synchronization: 100 m max.*between power supply and emitter, between power supply and<br>receiver, and between emitter and receiver<br>* When the Intelligent Tap (F39-SGIT-IL3) is connected to the sensor, this applies in the case of the rated<br>power supply of 24 VDC to 24 VDC +20%.|||||
|||**Cascade**<br>**connection**||Extension cable between sensors: 10 m max. (not including Cascading Cable for Extended*1 and Root<br>Cable*2.)<br>*1. F39-JGR3W<br>*2. F39-JGR3K|||||
|**Material**||||Housing: Aluminum alloy<br>Cap: PBT resin<br>Front window: Acrylic resin<br>Side-Mount Bracket (Intermediate Bracket)(F39-LSGF): Zinc alloy<br>FE plate: Stainless steel|||||
|**Weight**|||||Refer to page 24||||
|**Included accessories**||||Instruction Sheet, Quick Installation Manual, Troubleshooting Guide Sticker, Warning Zone Label, End Cap (for<br>switching Scan Code Selection function), Side-Mount Bracket (Intermediate Bracket) (F39-LSGF)*<br>* The quantity varies depending on the protective height.<br>Protective height of 0160 to 1440: 2 sets (total 4 pcs), 1520 to 2480: 3 sets (total 6 pcs)|||||
|**Conformity**|**Conforming standards**||||Refer to page 31||||
||**Type of ESPE (IEC 61496-1)**|||F3SG-4SR-: Type 4|||||
||**Performance Level**<br>**(PL)/Safety category**|||F3SG-4SR-: PL e/Category 4 (EN ISO 13849-1:2015)|||||
||**PFHD**|||F3SG-SR-: 1.1×10-8max. (IEC 61508)|||||
||**Proof test interval TM**|||Every 20 years (IEC 61508)|||||
||**SFF**|||99% (IEC 61508)|||||
||**HFT**|||1 (IEC 61508)|||||
||**Classification**|||Type B (IEC 61508-2)|||||
**20**
**F3SG-SR/PG**
## **Restrictions on cable extension**
For the cable extension of the F3SG-SR, refer to the following diagrams. For the cable extension of the F3SG-SR with the Intelligent Tap, refer to _User's Manual_ .
**==> picture [457 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
- Wired synchronization<br>(1) (3) (5)<br>Emitter Maximum extension length<br>(1) to (4): 10 m each *<br>Power (5) to (6): 100 m each<br>supply<br>Receiver<br>(2) (4) (6)<br>- Optical synchronization<br>(1) (3) Emitter (5) Powersupply Maximum extension length<br>(1) to (4): 10 m each *<br>(5) to (6): 100 m each<br>Power<br>Receiver<br>supply<br>(2) (4) (6)<br>**----- End of picture text -----**<br>
***** Not including Cascading Cable for Extended (F39-JGR3W) and Root Cable (F39-JGR3K).
**21**
**F3SG-SR/PG**
## **Intelligent Tap F39-SGIT-IL3**
||**Model**|**Model**|**F39-SGIT-IL3**|
|---|---|---|---|
|**Applicable sens**|**or**||F3SG-SR Series|
|**Performance**|**Response time**||Output ON to OFF and OFF to ON: 44 ms max. each*<br>* The response time is the time interval between the changes of the states of the sensor OSSD's and the DO (pin 2).|
||**Startup waiting time**||3 s max.|
|**Electrical**|**Power supply voltage (Vs)**||Supplied from external power source: SELV/PELV 24 VDC±20% (ripple p-p 10% max.)<br>USB bus powered: 5 VDC|
||**Current consumption**||85 mA max. (When connecting 24 VDC power supply and IO-Link Master)|
||**Safety outputs (OSSD)**<br>**/Auxiliary output**||Refer to the ratings and specifications of the F3SG-SR. The safety outputs and auxiliary output of the<br>Intelligent Tap are directly connected to those of the F3SG-SR.|
||**Digital output for pin 2 (IO-Link)**<br>*||One PNP transistor output<br>Load current: 100 mA max., Residual voltage: 2 V max., Leakage current: 1 mA max.<br>The DO is in the OFF state when the safety outputs are in the ON state. The DO is in the ON state when the<br>safety outputs are in the OFF state. (Regardless of the PNP/NPN setting of the F3SG-SR)|
||* For the DO (pin 2) of CN3|||
||**Input voltage**|**RESET, EDM**|PNP<br>ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA)*2<br>OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA)*2<br>NPN<br>ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)<br>OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA)*2|
|||**MUTE A/B,**<br>**PRE-RESET,**<br>**PSDI*1**|PNP<br>ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA)*2<br>OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA)*2<br>NPN<br>ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)<br>OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA)*2|
|||*1. PSDI is only available for F3SG-SR.<br>*2. The Vs indicates a supply voltage value in your environment.||
||**Overvoltage category**<br>**(IEC 60664-1)**||II|
||**Protective circuit**||Output short-circuit protection, Output reverse polarity protection|
||**Insulation resistance**||20 Mor higher (500 VDC megger)|
||**Dielectric strength**||1,000 VAC, 50/60 Hz (1 min)|
|**Functional**|**Maintenance Information**||Error Log<br>Power-ON Time|
|**Environmental**|**Ambient**<br>**temperature**|**Operating**|-30 to 55 °C (non-icing)|
|||**Storage**|-30 to 70 °C|
||**Ambient**<br>**humidity**|**Operating**|35% to 85% (non-condensing)|
|||**Storage**|35% to 85%|
||**Degree of protection (IEC 60529)**||IP65, IP67 and IP67G (Covers and cables connected with the Intelligent Tap.)|
||**Vibration resistance (IEC 61496-1)**||10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes|
||**Shock resistance (IEC 61496-1)**||100 m/s2, 1000 shocks for all 3 axes|
||**Pollution degree (IEC 60664-1)**||3|
|**Connections**|**To sensors, control box and IO-**<br>**Link**||M12 connectors: 8-pin (CN1: receiver and CN2: control box) and 5-pin (CN3: IO-Link and CN4: emitter),<br>IP67 and IP67G (JIS C 0920 Annex 1)*rated when mated.<br>* The F3SG-SR meets the degree of protection when the root cable of the F3SG-SR is correctly connected<br>with the F3SG-SR.|
||**Connection**||USB Type-C|
||**Cable extension**||20 m max. between IO-Link Master and Intelligent Tap, 4 m max.*between PC and Intelligent Tap via USB<br>cable<br>* It is not guaranteed that the Intelligent Tap is connectable to any PC or USB cable. Verify the connection<br>with the USB cable you use.|
|**IO-Link**<br>**communications**|**IO-Link version**||Version 1.1|
||**Baud rate**||COM3: 230.4 kbps|
||**Data length**||PD: 4 bytes, OD: 32 bytes (M-sequence type: TYPE_2_V)|
||**Minimum cycle time**||12 ms|
|**Material**|||PBT resin|
|**Weight**|||F39-SGIT-IL3: 180 g (when packaged), F39-LITF1: 50 g (when packaged)|
|**Included accessories**|||Instruction Sheet and M12 Connector Cover (2 pcs)|
**22**
**F3SG-SR/PG**
## **Bluetooth[®] Communication Unit**
|**Model**|**F39-SGBT**|
|---|---|
|**Applicable sensor**|F3SG-SR Series|
|**Power supply voltage (Vs)**|24 VDC±20%, ripple p-p 10% max. (shares power supply of Intelligent Tap)|
|**Current consumption**|30 mA max. (shares power supply of Intelligent Tap)|
|**Ambient temperature**|Operating: -30 to 55 °C (non-icing)<br>Storage: -30 to 70 °C|
|**Ambient humidity**|Operating: 35% to 85% (non-condensing)<br>Storage: 35% to 85%|
|**Degree of protection**|IP65, IP67 and IP67G (rated when connected to Intelligent Tap)|
|**Vibration resistance**|10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes|
|**Shock resistance**|100m/s2, 1000 shocks for all 3 axes|
|**Type of connection**|To be connected to Intelligent Tap|
|**Communication system**|Bluetooth®Version 3.0|
|**Communication profile**|SPP (Serial Port Profile)|
|**Transmission distance**|Approx. 10 m max. (Output power: Class 2)*|
|**Material**|PBT resin|
|**Weight**|70 g (when packaged)|
* It depends on use environment conditions.
**23**
**F3SG-SR/PG**
**List of Models/Response Time/Current Consumption/Weight**
## **F3SG-SR**
**Finger protection (Detection capability: 14-mm dia.) List of Models and Response Times**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|
|---|---|---|---|---|---|---|---|
||||**ON to**<br>**OFF**|**OFF**<br>**(synchronized)**<br>**to ON**|**OFF(not**<br>**synchronized)**<br>**to ON**|**ON to**<br>**OFF**|**OFF to**<br>**ON**|
|**F3SG-4SR****0160-14**|15|160|8|40|140|10|50|
|**F3SG-4SR****0200-14-F**|19|200|8|40|140|10|50|
|**F3SG-4SR****0240-14**|23|240|8|40|140|10|50|
|**F3SG-4SR****0280-14-F**|27|280|8|40|140|10|50|
|**F3SG-4SR****0320-14**|31|320|8|40|140|10|50|
|**F3SG-4SR****0360-14-F**|35|360|8|40|140|10|50|
|**F3SG-4SR****0400-14**|39|400|8|40|140|10|50|
|**F3SG-4SR****0440-14-F**|43|440|13|65|165|17|85|
|**F3SG-4SR****0480-14**|47|480|13|65|165|17|85|
|**F3SG-4SR****0520-14-F**|51|520|13|65|165|17|85|
|**F3SG-4SR****0560-14**|55|560|13|65|165|17|85|
|**F3SG-4SR****0600-14-F**|59|600|13|65|165|17|85|
|**F3SG-4SR****0640-14**|63|640|13|65|165|17|85|
|**F3SG-4SR****0680-14-F**|67|680|13|65|165|17|85|
|**F3SG-4SR****0720-14-F**|71|720|13|65|165|17|85|
|**F3SG-4SR****0760-14-F**|75|760|13|65|165|17|85|
|**F3SG-4SR****0800-14**|79|800|13|65|165|17|85|
|**F3SG-4SR****0840-14-F**|83|840|13|65|165|17|85|
|**F3SG-4SR****0880-14-F**|87|880|13|65|165|17|85|
|**F3SG-4SR****0920-14-F**|91|920|13|65|165|17|85|
|**F3SG-4SR****0960-14-F**|95|960|13|65|165|17|85|
|**F3SG-4SR****1000-14**|99|1000|13|65|165|17|85|
|**F3SG-4SR****1200-14**|119|1200|13|65|165|17|85|
|**F3SG-4SR****1400-14**|139|1400|13|65|165|17|85|
|**F3SG-4SR****1600-14**|159|1600|18|90|190|21|105|
|**F3SG-4SR****1800-14**|179|1800|18|90|190|21|105|
|**F3SG-4SR****2000-14**|199|2000|18|90|190|21|105|
- **Note: 1.** The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
**2.** The response times of “Optical synchronization” are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
**24**
**F3SG-SR/PG**
## **List of Models, Current Consumption and Weight**
|**Model**|**Number of beams**|**Protective height**<br>**[mm]**|**Current consumption [mA]**|**Current consumption [mA]**|**Weight [kg]**|**Weight [kg]**|
|---|---|---|---|---|---|---|
||||**Emitter**|**Receiver**|**Net**|**Gross**|
|**F3SG-4SRA0160-14**|15|160|68|106|0.4|1.2|
|**F3SG-****SRB0160-14**|15|160|69|97|0.4|1.2|
|**F3SG-4SRA0200-14-F**|19|200|71|108|0.5|1.3|
|**F3SG-4SRB0200-14-F**|19|200|70|97|0.5|1.3|
|**F3SG-4SRA0240-14**|23|240|74|111|0.6|1.4|
|**F3SG-****SRB0240-14**|23|240|71|98|0.6|1.4|
|**F3SG-4SRA0280-14-F**|27|280|77|114|0.7|1.5|
|**F3SG-4SRB0280-14-F**|27|280|73|99|0.7|1.5|
|**F3SG-4SRA0320-14**|31|320|81|117|0.8|1.6|
|**F3SG-****SRB0320-14**|31|320|74|100|0.8|1.6|
|**F3SG-4SRA0360-14-F**|35|360|84|119|0.9|1.8|
|**F3SG-4SRB0360-14-F**|35|360|75|100|0.9|1.8|
|**F3SG-4SRA0400-14**|39|400|87|122|1|1.9|
|**F3SG-****SRB0400-14**|39|400|77|101|1|1.9|
|**F3SG-4SRA0440-14-F**|43|440|90|125|1.1|2|
|**F3SG-4SRB0440-14-F**|43|440|78|102|1.1|2|
|**F3SG-4SRA0480-14**|47|480|93|128|1.2|2.1|
|**F3SG-****SRB0480-14**|47|480|79|103|1.2|2.1|
|**F3SG-4SRA0520-14-F**|51|520|96|131|1.3|2.2|
|**F3SG-4SRB0520-14-F**|51|520|81|103|1.3|2.2|
|**F3SG-4SRA0560-14**|55|560|99|133|1.4|2.3|
|**F3SG-****SRB0560-14**|55|560|82|104|1.4|2.3|
|**F3SG-4SRA0600-14-F**|59|600|103|136|1.5|2.5|
|**F3SG-4SRB0600-14-F**|59|600|83|105|1.5|2.5|
|**F3SG-4SRA0640-14**|63|640|106|139|1.6|2.6|
|**F3SG-****SRB0640-14**|63|640|85|106|1.6|2.6|
|**F3SG-4SRA0680-14-F**|67|680|109|142|1.7|2.7|
|**F3SG-4SRB0680-14-F**|67|680|86|106|1.7|2.7|
|**F3SG-4SRA0720-14-F**|71|720|112|144|1.8|2.8|
|**F3SG-4SRB0720-14-F**|71|720|87|107|1.8|2.8|
|**F3SG-4SRA0760-14-F**|75|760|115|147|1.9|2.9|
|**F3SG-4SRB0760-14-F**|75|760|89|108|1.9|2.9|
|**F3SG-4SRA0800-14**|79|800|118|150|2|3|
|**F3SG-****SRB0800-14**|79|800|90|109|2|3|
|**F3SG-4SRA0840-14-F**|83|840|121|153|2.1|3.1|
|**F3SG-4SRB0840-14-F**|83|840|91|109|2.1|3.1|
|**F3SG-4SRA0880-14-F**|87|880|124|155|2.2|3.2|
|**F3SG-4SRB0880-14-F**|87|880|93|110|2.2|3.2|
|**F3SG-4SRA0920-14-F**|91|920|128|158|2.3|3.4|
|**F3SG-4SRB0920-14-F**|91|920|94|111|2.3|3.4|
|**F3SG-4SRA0960-14-F**|95|960|131|161|2.4|3.5|
|**F3SG-4SRB0960-14-F**|95|960|95|112|2.4|3.5|
|**F3SG-4SRA1000-14**|99|1000|134|164|2.5|3.6|
|**F3SG-****SRB1000-14**|99|1000|97|112|2.5|3.6|
|**F3SG-4SRA1200-14**|119|1200|150|178|3.1|4.2|
|**F3SG-****SRB1200-14**|119|1200|103|116|3.1|4.2|
|**F3SG-4SRA1400-14**|139|1400|165|191|3.6|4.7|
|**F3SG-****SRB1400-14**|139|1400|110|120|3.6|4.7|
|**F3SG-4SRA1600-14**|159|1600|181|205|4.1|5.5|
|**F3SG-****SRB1600-14**|159|1600|117|124|4.1|5.5|
|**F3SG-4SRA1800-14**|179|1800|197|219|4.6|6.1|
|**F3SG-****SRB1800-14**|179|1800|124|128|4.6|6.1|
|**F3SG-4SRA2000-14**|199|2000|212|233|5.1|6.7|
|**F3SG-****SRB2000-14**|199|2000|130|131|5.1|6.7|
**Note: 1.** The net weight is the weight of an emitter and a receiver per set.
**2.** The gross weight is the weight of an emitter, a receiver, included accessories and a package.
**25**
**F3SG-SR/PG**
## **Hand protection (Detection capability: 25-mm dia.) List of Models and Response Times**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|
|---|---|---|---|---|---|---|---|
||||**ON to**<br>**OFF**|**OFF**<br>**(synchronized)**<br>**to ON**|**OFF(not**<br>**synchronized)**<br>**to ON**|**ON to**<br>**OFF**|**OFF to**<br>**ON**|
|**F3SG-4SR****0160-25**|8|160|8|40|140|10|50|
|**F3SG-4SR****0200-25-F**|10|200|8|40|140|10|50|
|**F3SG-4SR****0240-25**|12|240|8|40|140|10|50|
|**F3SG-4SR****0280-25-F**|14|280|8|40|140|10|50|
|**F3SG-4SR****0320-25**|16|320|8|40|140|10|50|
|**F3SG-4SR****0360-25-F**|18|360|8|40|140|10|50|
|**F3SG-4SR****0400-25**|20|400|8|40|140|10|50|
|**F3SG-4SR****0440-25-F**|22|440|8|40|140|10|50|
|**F3SG-4SR****0480-25**|24|480|8|40|140|10|50|
|**F3SG-4SR****0520-25-F**|26|520|8|40|140|10|50|
|**F3SG-4SR****0560-25**|28|560|8|40|140|10|50|
|**F3SG-4SR****0600-25-F**|30|600|8|40|140|10|50|
|**F3SG-4SR****0640-25**|32|640|8|40|140|10|50|
|**F3SG-4SR****0680-25-F**|34|680|8|40|140|10|50|
|**F3SG-4SR****0720-25**|36|720|8|40|140|10|50|
|**F3SG-4SR****0760-25-F**|38|760|8|40|140|10|50|
|**F3SG-4SR****0800-25**|40|800|8|40|140|10|50|
|**F3SG-4SR****0840-25-F**|42|840|13|65|165|17|85|
|**F3SG-4SR****0880-25**|44|880|13|65|165|17|85|
|**F3SG-4SR****0920-25-F**|46|920|13|65|165|17|85|
|**F3SG-4SR****0960-25**|48|960|13|65|165|17|85|
|**F3SG-4SR****1000-25-F**|50|1000|13|65|165|17|85|
|**F3SG-4SR****1040-25**|52|1040|13|65|165|17|85|
|**F3SG-4SR****1120-25**|56|1120|13|65|165|17|85|
|**F3SG-4SR****1200-25**|60|1200|13|65|165|17|85|
|**F3SG-4SR****1280-25**|64|1280|13|65|165|17|85|
|**F3SG-4SR****1360-25**|68|1360|13|65|165|17|85|
|**F3SG-4SR****1440-25**|72|1440|13|65|165|17|85|
|**F3SG-4SR****1520-25**|76|1520|13|65|165|17|85|
|**F3SG-4SR****1600-25**|80|1600|13|65|165|17|85|
|**F3SG-4SR****1680-25**|84|1680|13|65|165|17|85|
|**F3SG-4SR****1760-25**|88|1760|13|65|165|17|85|
|**F3SG-4SR****1840-25**|92|1840|13|65|165|17|85|
|**F3SG-4SR****1920-25**|96|1920|13|65|165|17|85|
|**F3SG-4SR****2080-25**|104|2080|13|65|165|17|85|
|**F3SG-4SR****2280-25**|114|2280|13|65|165|17|85|
|**F3SG-4SR****2480-25**|124|2480|13|65|165|17|85|
- **Note: 1.** The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
**2.** The response times of "Optical synchronization" are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
**26**
**F3SG-SR/PG**
## **List of Models, Current Consumption and Weight**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Current consumption [mA]**|**Current consumption [mA]**|**Weight [kg]**|**Weight [kg]**|
|---|---|---|---|---|---|---|
||||**Emitter**|**Receiver**|**Net**|**Gross**|
|**F3SG-4SRA0160-25**|8|160|63|105|0.4|1.2|
|**F3SG-****SRB0160-25**|8|160|61|96|0.4|1.2|
|**F3SG-4SRA0200-25-F**|10|200|65|108|0.5|1.3|
|**F3SG-4SRB0200-25-F**|10|200|62|96|0.5|1.3|
|**F3SG-4SRA0240-25**|12|240|68|110|0.6|1.4|
|**F3SG-****SRB0240-25**|12|240|63|97|0.6|1.4|
|**F3SG-4SRA0280-25-F**|14|280|71|112|0.7|1.5|
|**F3SG-4SRB0280-25-F**|14|280|64|97|0.7|1.5|
|**F3SG-4SRA0320-25**|16|320|74|115|0.8|1.6|
|**F3SG-****SRB0320-25**|16|320|65|97|0.8|1.6|
|**F3SG-4SRA0360-25-F**|18|360|76|117|0.9|1.8|
|**F3SG-4SRB0360-25-F**|18|360|65|98|0.9|1.8|
|**F3SG-4SRA0400-25**|20|400|79|119|1|1.9|
|**F3SG-****SRB0400-25**|20|400|66|98|1|1.9|
|**F3SG-4SRA0440-25-F**|22|440|82|121|1.1|2|
|**F3SG-4SRB0440-25-F**|22|440|67|98|1.1|2|
|**F3SG-4SRA0480-25**|24|480|84|124|1.2|2.1|
|**F3SG-****SRB0480-25**|24|480|68|99|1.2|2.1|
|**F3SG-4SRA0520-25-F**|26|520|87|126|1.3|2.2|
|**F3SG-4SRB0520-25-F**|26|520|69|99|1.3|2.2|
|**F3SG-4SRA0560-25**|28|560|90|128|1.4|2.3|
|**F3SG-****SRB0560-25**|28|560|70|99|1.4|2.3|
|**F3SG-4SRA0600-25-F**|30|600|92|131|1.5|2.5|
|**F3SG-4SRB0600-25-F**|30|600|71|100|1.5|2.5|
|**F3SG-4SRA0640-25**|32|640|95|133|1.6|2.6|
|**F3SG-****SRB0640-25**|32|640|72|100|1.6|2.6|
|**F3SG-4SRA0680-25-F**|34|680|98|135|1.7|2.7|
|**F3SG-4SRB0680-25-F**|34|680|73|100|1.7|2.7|
|**F3SG-4SRA0720-25**|36|720|100|137|1.8|2.8|
|**F3SG-****SRB0720-25**|36|720|74|101|1.8|2.8|
|**F3SG-4SRA0760-25-F**|38|760|103|140|1.9|2.9|
|**F3SG-4SRB0760-25-F**|38|760|75|101|1.9|2.9|
|**F3SG-4SRA0800-25**|40|800|106|142|2|3|
|**F3SG-****SRB0800-25**|40|800|76|101|2|3|
|**F3SG-4SRA0840-25-F**|42|840|109|144|2.1|3.1|
|**F3SG-4SRB0840-25-F**|42|840|77|101|2.1|3.1|
|**F3SG-4SRA0880-25**|44|880|111|147|2.2|3.2|
|**F3SG-****SRB0880-25**|44|880|78|102|2.2|3.2|
|**F3SG-4SRA0920-25-F**|46|920|114|149|2.3|3.4|
|**F3SG-4SRB0920-25-F**|46|920|79|102|2.3|3.4|
|**F3SG-4SRA0960-25**|48|960|117|151|2.4|3.5|
|**F3SG-****SRB0960-25**|48|960|80|102|2.4|3.5|
|**F3SG-4SRA1000-25-F**|50|1000|119|154|2.5|3.6|
|**F3SG-4SRB1000-25-F**|50|1000|81|103|2.5|3.6|
|**F3SG-4SRA1040-25**|52|1040|122|156|2.6|3.7|
|**F3SG-****SRB1040-25**|52|1040|82|103|2.6|3.7|
|**F3SG-4SRA1120-25**|56|1120|127|160|2.9|3.9|
|**F3SG-****SRB1120-25**|56|1120|84|104|2.9|3.9|
|**F3SG-4SRA1200-25**|60|1200|133|165|3.1|4.2|
|**F3SG-****SRB1200-25**|60|1200|86|104|3.1|4.2|
|**F3SG-4SRA1280-25**|64|1280|138|170|3.3|4.4|
|**F3SG-****SRB1280-25**|64|1280|88|105|3.3|4.4|
|**F3SG-4SRA1360-25**|68|1360|144|174|3.5|4.6|
|**F3SG-****SRB1360-25**|68|1360|90|106|3.5|4.6|
**27**
**F3SG-SR/PG**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Current consumption [mA]**|**Current consumption [mA]**|**Weight [kg]**|**Weight [kg]**|
|---|---|---|---|---|---|---|
||||**Emitter**|**Receiver**|**Net**|**Gross**|
|**F3SG-4SRA1440-25**|72|1440|149|179|3.7|4.8|
|**F3SG-****SRB1440-25**|72|1440|92|106|3.7|4.8|
|**F3SG-4SRA1520-25**|76|1520|154|183|3.9|5.3|
|**F3SG-****SRB1520-25**|76|1520|93|107|3.9|5.3|
|**F3SG-4SRA1600-25**|80|1600|160|188|4.1|5.5|
|**F3SG-****SRB1600-25**|80|1600|95|107|4.1|5.5|
|**F3SG-4SRA1680-25**|84|1680|165|192|4.3|5.8|
|**F3SG-****SRB1680-25**|84|1680|97|108|4.3|5.8|
|**F3SG-4SRA1760-25**|88|1760|170|197|4.5|6|
|**F3SG-****SRB1760-25**|88|1760|99|109|4.5|6|
|**F3SG-4SRA1840-25**|92|1840|176|202|4.7|6.2|
|**F3SG-****SRB1840-25**|92|1840|101|109|4.7|6.2|
|**F3SG-4SRA1920-25**|96|1920|181|206|4.9|6.4|
|**F3SG-****SRB1920-25**|96|1920|103|110|4.9|6.4|
|**F3SG-4SRA2080-25**|104|2080|192|215|5.3|6.9|
|**F3SG-****SRB2080-25**|104|2080|107|111|5.3|6.9|
|**F3SG-4SRA2280-25**|114|2280|205|227|5.8|7.5|
|**F3SG-****SRB2280-25**|114|2280|112|113|5.8|7.5|
|**F3SG-4SRA2480-25**|124|2480|219|238|6.3|8|
|**F3SG-****SRB2480-25**|124|2480|117|114|6.3|8|
**Note: 1.** The net weight is the weight of an emitter and a receiver per set.
**2.** The gross weight is the weight of an emitter, a receiver, included accessories and a package.
**28**
**F3SG-SR/PG**
## **Arm/leg protection (Detection capability: 45-mm dia.) List of Models and Response Times**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|
|---|---|---|---|---|---|---|---|
||||**ON to**<br>**OFF**|**OFF**<br>**(synchronized)**<br>**to ON**|**OFF(not**<br>**synchronized)**<br>**to ON**|**ON to**<br>**OFF**|**OFF to**<br>**ON**|
|**F3SG-4SR****0240-45**|6|240|8|40|140|10|50|
|**F3SG-4SR****0400-45**|10|400|8|40|140|10|50|
|**F3SG-4SR****0560-45**|14|560|8|40|140|10|50|
|**F3SG-4SR****0720-45**|18|720|8|40|140|10|50|
|**F3SG-4SR****0880-45**|22|880|8|40|140|10|50|
|**F3SG-4SR****1200-45**|30|1200|8|40|140|10|50|
|**F3SG-4SR****1520-45**|38|1520|8|40|140|10|50|
**Note: 1.** The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
**2.** The response times of "Optical synchronization" are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
## **List of Models, Current Consumption and Weight**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Current consumption [mA]**|**Current consumption [mA]**|**Weight [kg]**|**Weight [kg]**|
|---|---|---|---|---|---|---|
||||**Emitter**|**Receiver**|**Net**|**Gross**|
|**F3SG-4SRA0240-45**|6|240|60|107|0.6|1.4|
|**F3SG-****SRB0240-45**|6|240|52|95|0.6|1.4|
|**F3SG-4SRA0400-45**|10|400|71|116|1|1.9|
|**F3SG-****SRB0400-45**|10|400|56|95|1|1.9|
|**F3SG-4SRA0560-45**|14|560|82|124|1.4|2.3|
|**F3SG-****SRB0560-45**|14|560|60|96|1.4|2.3|
|**F3SG-4SRA0720-45**|18|720|93|133|1.8|2.8|
|**F3SG-****SRB0720-45**|18|720|64|96|1.8|2.8|
|**F3SG-4SRA0880-45**|22|880|104|141|2.2|3.2|
|**F3SG-****SRB0880-45**|22|880|68|97|2.2|3.2|
|**F3SG-4SRA1200-45**|30|1200|125|158|3.1|4.2|
|**F3SG-****SRB1200-45**|30|1200|75|98|3.1|4.2|
|**F3SG-4SRA1520-45**|38|1520|147|175|3.9|5.3|
|**F3SG-****SRB1520-45**|38|1520|83|99|3.9|5.3|
**Note: 1.** The net weight is the weight of an emitter and a receiver per set.
**2.** The gross weight is the weight of an emitter, a receiver, included accessories and a package.
**29**
**F3SG-SR/PG**
## **Body protection (Detection capability: 85-mm dia.) List of Models and Response Times**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Optical synchronization) [ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|**Response time**<br>**(Wired**<br>**synchronization)**<br>**[ms]**|
|---|---|---|---|---|---|---|---|
||||**ON to**<br>**OFF**|**OFF**<br>**(synchronized)**<br>**to ON**|**OFF(not**<br>**synchronized)**<br>**to ON**|**ON to**<br>**OFF**|**OFF to**<br>**ON**|
|**F3SG-4SR****0280-85**|4|280|8|40|140|10|50|
|**F3SG-4SR****0440-85**|6|440|8|40|140|10|50|
|**F3SG-4SR****0600-85**|8|600|8|40|140|10|50|
|**F3SG-4SR****0760-85**|10|760|8|40|140|10|50|
|**F3SG-4SR****0920-85**|12|920|8|40|140|10|50|
**Note: 1.** The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s. **2.** The response times of "Optical synchronization" are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
## **List of Models, Current Consumption and Weight**
|**Model**|**Number of**<br>**beams**|**Protective**<br>**height [mm]**|**Current consumption [mA]**|**Current consumption [mA]**|**Weight [kg]**|**Weight [kg]**|
|---|---|---|---|---|---|---|
||||**Emitter**|**Receiver**|**Net**|**Gross**|
|**F3SG-4SRA0280-85**|4|280|63|111|0.7|1.5|
|**F3SG-****SRB0280-85**|4|280|50|95|0.7|1.5|
|**F3SG-4SRA0440-85**|6|440|72|120|1.1|2|
|**F3SG-****SRB0440-85**|6|440|52|95|1.1|2|
|**F3SG-4SRA0600-85**|8|600|81|128|1.5|2.5|
|**F3SG-****SRB0600-85**|8|600|54|96|1.5|2.5|
|**F3SG-4SRA0760-85**|10|760|91|136|1.9|2.9|
|**F3SG-****SRB0760-85**|10|760|56|96|1.9|2.9|
|**F3SG-4SRA0920-85**|12|920|100|145|2.3|3.4|
|**F3SG-****SRB0920-85**|12|920|58|96|2.3|3.4|
**Note: 1.** The net weight is the weight of an emitter and a receiver per set.
**2.** The gross weight is the weight of an emitter, a receiver, included accessories and a package.
**30**
**F3SG-SR/PG**
## **Legislation and Standards**
**1.** The F3SG-SR does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of Japan. When using the F3SG-SR in Japan as a "safety system for pressing or shearing machines" prescribed in Article 42 of that law, the machine control system must receive type approval.
**2.** The F3SG-SR is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery Directive Index Annex V, Item 2.
**3.** EU Declaration of Conformity
OMRON declares that the F3SG-SR is in conformity with the requirements of the following EU Directives: Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU
**4.** Conforming Standards
- (1) European standards
EN61496-1 (Type 4 and Type 2 ESPE), EN 61496-2 (Type 4 and Type 2 AOPD), EN61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
- (2) International standards
IEC61496-1 (Type 4 and Type 2 ESPE), IEC61496-2 (Type 4 and Type 2 AOPD), IEC61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for Type 2), ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
- (3) JIS standards
JIS B 9704-1 (Type 4 and Type 2 ESPE), JIS B 9704-2 (Type 4 and Type 2 AOPD)
- (4) North American standards
- UL61496-1 (Type 4 and Type 2 ESPE), UL61496-2 (Type 4 and Type 2 AOPD), UL508, UL1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
- (5) Chinese standards
GB/T 4584 (Specification of active opto-electronic protective devices for presses)
- (Models: F3SG-4SR-14/-25 in the case of the ON to OFF response time not exceeding 20 ms max.)
The following configurations of the F3SG-SR are compliant with GB/T 4584.
Configurations using the F3SG-SR with detection capability of 14-mm or 25-mm dia. and 20 ms max. of the ON to OFF response time
|**Detection capability**|**Protective height**|**Number of**<br>**beams**|**Configuration**|**Synchronization**<br>**method**|**Response Time**<br>**Adjustment**|**ON to OFF**<br>**response time**|
|---|---|---|---|---|---|---|
|14-mm dia.|160 to 2000 mm|-|Single|Optical|Normal|18 ms max.|
|14-mm dia.|160 to 1400 mm|-|Single|Wired|Normal|17 ms max.|
|25-mm dia.|160 to 2480 mm|-|Single|Optical/Wired|Normal|17 ms max.|
|Combination of 14-mm 25-mm dia.<br>In cascade connection|-|255 max.|Cascaded|Optical|Normal|18 ms max.*|
|Combination of 14-mm 25-mm dia.<br>In cascade connection|-|140 max.|Cascaded|Wired|Normal|15 ms max.*|
* Refer to _User's Manual_ for more information on the response time for the F3SG-SR in cascade connection.
- **Note:** The F3SG-SR's with detection capability of 45-mm and 85-mm dia. are not compliant with GB/T 4584. Refer to _Ratings and Specifications_ on page 18 for more information on the ratings and specifications by model.
**5.** Third-Party Certifications
- (1) TÜV SÜD
- EC Type-Examination certificate:
EU Machinery Directive, Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN 61496-2)
- Certificate:
Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4, and PL c, Category 2 for Type 2)
- (2) UL
- UL Listing:
- Type 4 and Type 2 ESPE (UL61496-1), Type 4 and Type 2 AOPD (UL61496-2), UL508, UL1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
- (3) China National Casting and Forging Machines Quality Supervision and Inspection Center
- Certificate:
GB/T 4584 (Specification of active opto-electronic protective devices for presses)
- (Models: F3SG-4SR-14/-25 in the case of the ON to OFF response time not exceeding 20 ms max.)
**6.** Other Standards
The F3SG-SR/PG is designed according to the standards listed below. To make sure that the final system complies with the following standards and regulations, you are asked to design and use it in accordance with all other related standards, laws, and regulations. If you have any questions, consult with specialized organizations such as the body responsible for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to be used.
- European Standards: EN415-4, EN691-1, EN692, EN693, IEC 62046
- U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
- U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
- American National Standards: ANSI B11.1 to B11.19
- American National Standards: ANSI/RIA R15.06
- Canadian Standards Association CSA Z142, Z432, Z434
- SEMI Standards SEMI S2
- Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery", Standard Bureau's Notification No. 0731001 dated July 31, 2007.rms and Conditions Agreement
- Chinese National Standards: GB17120, GB27607
**7.** Meaning of mark according to EU WEEE Directive
Dispose in accordance with applicable regulations.
**8.** Regions where F39-SGBT can be used
For the regions where the F39-SGBT can be used, refer to the following instruction manuals of the F39-SGBT.
|**Document Title**|**No.**|
|---|---|
|F39-SGBT Instruction Sheet|4615743-0|
|F39-SGBT Regulations and Standards|4615744-8|
**31**
**F3SG-SR/PG**
## **Indicator**
## **LED Indicators on F3SG-SR**
Shown below are indication statuses of the LED indicators on the F3SG-SR when you purchased.
## **Emitter (F3SG-SR)**
|**Location**|**Indicator**|**Name**|**Color**|**Illuminated**|**Blinking**|**F3SG-SRA**|**F3SG-SRB**|
|---|---|---|---|---|---|---|---|
|1|CODE<br>C<br>or|Scan code|Green|Code A is selected|---|X|X|
||||Orange|Code B is selected||||
||||OFF|Automatic interference prevention<br>by wired synchronization being<br>performed||||
|2|ERR<br>E<br>or|Lockout|Red|LOCKOUT state. The indicator is<br>illuminated in the emitter of another<br>sensor segment than that having a<br>lockout error (when in cascade<br>connection or between the emitter<br>and receiver in the Wired<br>Synchronization)|LOCKOUT state. The indicator is<br>illuminated in the emitter of a sensor<br>segment having a lockout error|X|X|
|3|LONG<br>L<br>or|Operating<br>range|Green|Long Mode is selected|LOCKOUT state due to Operating<br>range selection setting error|X|X|
||||OFF|Short Mode is selected||||
|4|TEST<br>T<br>or|Test|Yellow|---|External Test is being performed|X|X|
|5|---|Area Beam<br>Indicator (ABI)<br>(*1)|Green|The target beams of the ABI are<br>unblocked and the safety outputs<br>are turned ON|MUTING or OVERRIDE state. In the<br>MUTING state, only the ABI<br>indicators in the muting zone are<br>blinking. Or the target beams of the<br>ABI are blocked instantaneously|X|---|
||||Orange|Incident light level of the target<br>beams of the ABI is 170% (factory<br>default setting (*2)) or less of ON-<br>threshold (for 5 to 10 s)|Incident light level of the target beams<br>of the ABI is 170% (factory default<br>setting (*2)) or less of ON threshold<br>5 to 10 s after illuminated when<br>incident light level of the target beams<br>of the ABI is 170% (factory default<br>setting (*2)) or less of ON threshold.<br>Or one muting input becomes the ON<br>state and the MUTING state has not<br>been started yet, or one muting input<br>becomes the OFF state and the other<br>is not in the OFF state yet. (*3)|||
||||Red|The target beams of the ABI are<br>blocked|LOCKOUT state due to Cap error or<br>Other sensor error (*4), or Lockout<br>state due to DIP Switch setting error<br>(*5*6)|||
||||OFF|The target beams of the ABI are<br>unblocked (The ABI then will be<br>illuminated in green when the safety<br>outputs are turned ON.)|---|||
|6|TOP|Top-beam-<br>state (*1)|Blue|The top beam is unblocked|MUTING/OVERRIDE state, or<br>LOCKOUT state due to Cap error or<br>Other sensor error|---|X|
|7|BTM|Bottom-beam-<br>state (*1)|Blue|The bottom beam is unblocked|MUTING/OVERRIDE, or LOCKOUT<br>state due to DIP Switch setting error<br>(*6)|---|X|
- *1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the Optical Synchronization is enabled.
- *2. Configurable by SD Manager 3.
- *3. This is the case for the Standard Muting mode. For other muting modes, refer to _User's Manual_ .
- *4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
- *5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
- *6. DIP switches is on the Intelligent Tap.
**32**
**F3SG-SR/PG**
## **Receiver (F3SG-SR)**
|**Location**|**Indicator**|**Name**|**Color**|**Illuminated**|**Blinking**|**F3SG-SRA**|**F3SG-SRB**|
|---|---|---|---|---|---|---|---|
|1|CODE<br>C<br>or|Scan code|Green|Code A is selected|---|X|X|
||||Orange|Code B is selected||||
||||OFF|Automatic interference prevention by<br>wired synchronization being<br>performed||||
|2|ERR<br>E<br>or|Lockout|Red|LOCKOUT state. The indicator is<br>illuminated in the receiver of another<br>sensor segment than that having a<br>lockout error (when in cascade<br>connection or between the emitter and<br>receiver in the Wired Synchronization)|LOCKOUT state. The indicator is<br>illuminated in the receiver of a sensor<br>segment having a lockout error|X|X|
|3|OSSD<br>O<br>or|ON/OFF|Green|Safety outputs are in ON state|---|X|X|
||||Red|Safety outputs are in OFF state|LOCKOUT state due to Safety output error,<br>or error due to abnormal power supply or<br>noise|X|X|
|4|MAINT<br>M<br>or|Maintenance|Red|LOCKOUT state due to a<br>recoverable error (When in cascade<br>connection, the indicator of only the<br>sensor segment having the error is<br>illuminated)|LOCKOUT state due to a replacement-<br>recommended error (When in cascade<br>connection, the indicator of only the sensor<br>segment having the error blinks)|X|X|
||||Orange|Safety outputs are instantaneously<br>turned OFF due to ambient light,<br>vibration or noise. Or sequence error<br>in Muting, Pre-Reset or PSDI|Intelligent Tap is in the LOCKOUT state|X|X|
|5|PNP<br>P<br>or|PNP/NPN<br>mode|Green|PNP is configured|Polarity of PNP is changed to NPN, or vice<br>versa, during operation, and internal circuit<br>is defective|X|X|
||||OFF|NPN is configured||||
|6|CFG<br>F<br>or|Configuration|Green|Fixed or Floating Blanking, Reduced<br>Resolution, Warning Zone or Slow<br>mode of Response Time Adjustment<br>is enabled. Or after the Muting zone<br>is determined by the Dynamic Muting<br>function.|TEACH-IN mode, zone measurement<br>being performed by Dynamic Muting, or<br>LOCKOUT state due to Blanking<br>monitoring error, Configuration error or<br>Parameter error|X|X|
|7|SEQ<br>S<br>or|Sequence|Yellow|INTERLOCK state|Sequence or sequence error in Muting,<br>Pre-Reset or PSDI (*1) or Teach-in error|X|X|
|8|---|Area Beam<br>Indicator (ABI)|Green|The target beams of the ABI are<br>unblocked and the safety outputs are<br>turned ON|MUTING or OVERRIDE state. In the<br>MUTING state, only the ABI indicators in<br>the muting zone are blinking. Or the target<br>beams of the ABI are blocked<br>instantaneously|X|---|
||||Orange|Incident light level of the target<br>beams of the ABI is 170% (factory<br>default setting (*2)) or less of ON-<br>threshold (for 5 to 10 s)|Incident light level of the target beams of<br>the ABI is 170% (factory default setting<br>(*2)) or less of ON threshold 5 to 10 s after<br>illuminated when incident light level of the<br>target beams of the ABI is 170% (factory<br>default setting (*2)) or less of ON threshold.<br>Or one muting input becomes the ON state<br>and the MUTING state has not been started<br>yet, or one muting input becomes the OFF<br>state and the other is not in the OFF state<br>yet. (*3)|||
||||Red|The target beams of the ABI are<br>blocked|LOCKOUT state due to Cap error or Other<br>sensor error (*4), or LOCKOUT state due to<br>DIP Switch setting error (*5*6)|||
||||OFF|The target beams of the ABI are<br>unblocked (The ABI then will be<br>illuminated in green when the safety<br>outputs are turned ON.)|---|||
|9|TOP|Top-beam-<br>state|Blue|The top beam is unblocked|MUTING/OVERRIDE state, or LOCKOUT<br>state due to Cap error or Other sensor error|---|X|
|10|BTM|Bottom-beam-<br>state|Blue|The bottom beam is unblocked|MUTING/OVERRIDE state, or LOCKOUT<br>state due to DIP Switch setting error (*6)|---|X|
*1. Refer to _Troubleshooting_ on page 64 for more information on blinking patterns.
*2. Configurable by SD Manager 3.
- *3. This is the case for the Standard Muting mode. For other muting modes, refer to _User's Manual_ .
- *4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
- *5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
- *6. DIP switches is on the Intelligent Tap.
**Note:** In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter and the CFG, PNP and CODE indicators on the receiver blink. (TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green) For more information on the statuses of the LED indicators in the SETTING state, refer to User's Manual.
**33**
**F3SG-SR/PG**
## **LED Indicators on Intelligent Tap**
Shown below are indication statuses of LED indicators on the Intelligent Tap when you purchased.
|**Location**|**Indicator**|**Name**|**Color**|**Illuminated**|**Blinking**|
|---|---|---|---|---|---|
|1|IN|Sensor status|Yellow|Safety outputs of the F3SG-SR are in the ON<br>state|The F3SG-SR is in the LOCKOUT state. Or<br>the Intelligent Tap is waiting for Push Switch<br>operation (in the Backup) or the Intelligent<br>Tap and F3SG-SR are waiting for restart (in<br>the Backup). Or communication error in the<br>Backup or between the F3SG-SR and the<br>Intelligent Tap. Or the Restoration failed|
|2|OUT|Output status|Green|Outputs of the Intelligent Tap are in the ON<br>state(*1)|The Restoration failed.<br>Or in the Restoration, the Intelligent Tap has<br>communication error, is waiting for Push<br>Switch operation or transferring data, or the<br>Intelligent Tap and F3SG-SR are waiting for<br>restart.|
||||Red|Outputs of the Intelligent Tap are in the OFF<br>state (*2)|Communication error between the F3SG-SR<br>and the Intelligent Tap|
|3|IO-Link|IO-Link|Green|---|Intelligent Tap communicates with IO-Link<br>Master. Or IO-Link circuit error|
|4|ERR|Lockout|Red|The Intelligent Tap is in the LOCKOUT state,<br>or has communication error, DIP Switch<br>circuit error at startup, communication error in<br>the Backup or Restoration, restoration failure,<br>IO-Link circuit error, power supply voltage<br>error or other errors|---|
*1. When the safety outputs of the F3SG-SR are in the ON state, the outputs of the Intelligent Tap are in the ON state.
*2. When the safety outputs of the F3SG-SR are in the OFF state, the outputs of the Intelligent Tap are in the OFF state.
**Note:** In the SETTING state to make settings with the SD Manager 3, the IN, OUT indicators blink. (IN: Yellow, OUT: Green) For more information on the statuses of the LED indicators in the SETTING state, refer to User's Manual.
**34**
**F3SG-SR/PG**
## **Connections (Basic Wiring Diagram)**
## **F3SG-SR**
Examples of a motor control system using the F3SG-SR are shown below. The examples are equivalent to up to PLe, Category 4 (ISO 13849-1). **Non-Muting System Wiring Examples**
## **Auto Reset Mode with Optical Synchronization and EDM Unused**
## **[Wiring Example]**
**==> picture [420 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
Intelligent Tap Not needed<br>F39-JG�C-L F39-JG�C-D<br>Wiring for NPN * 1<br>24 VDC<br>24 VDC<br>* 7<br>IN1 IN2<br>Safety controller<br>* 5 * 6<br>Emitter Receiver<br>2<br>*<br>* 3 ) ) )<br>(Brown (Blue ) * 4 ) (White<br>(Red<br>0V/24V (Blue) Not used (White) OPERATING RANGE SELECT INPUT (Yellow) TEST (Black) 24V/0V 0V/24V RESET/EDM (Yellow MUTE A (Gray) MUTE B (Pink) AUX OSSD 1 (Black) OSSD 2 24V/0V (Brown)<br>**----- End of picture text -----**<br>
|**Function**|**Setting**|
|---|---|
|EDM|EDM Disabled (factory default setting)|
|Interlock|Auto Reset (factory default setting)|
|Operating Range Selection|Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.|
|Non-Muting system|Perform wiring according to the wiring diagram.|
|External Test not used|Connect the TEST line of the emitter to 0V/24V of the emitter.|
|Optical Synchronization|Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.|
- *1. Reverse the polarity of the power supply when using in the NPN system. Select a safety controller of PNP or NPN type according to the system of your application.
- Timing chart controller of PNP or NPN type according to the system of your application.
- Beam state: Unblocked *2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode. Blocked *3. If External Test is used, refer to the _User's Manual_ . OSSD *4. Connect the line to 24V/0V (brown) of the receiver via a lockout reset switch (NC contact) if Lockout Reset is used.
- *5. Refer to page 44 for more information.
- *6. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *7. This is the case for a PELV circuit.
- **Note: 1.** Functional earth connection to the F3SG-SR housing is unnecessary when you use the F3SG-SR in a general industrial environment where noise control or stable power supply is considered. However, when you use the F3SG-SR in an environment where there may be excessive noise from surroundings or stable power supply may be interfered, it is recommended the F3SG-SR be connected to functional earth.
**2.** The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable according to the example above. Refer to the _User's Manual_ for more information.
**35**
**F3SG-SR/PG**
**Auto Reset Mode with Wired Synchronization and EDM Unused [Wiring Example]**
**==> picture [488 x 410] intentionally omitted <==**
**----- Start of picture text -----**<br>
Intelligent Tap Not needed<br>F39-JG�C-L F39-JG�C-D<br>Wiring for NPN * 1<br>24 VDC<br>24 VDC<br>* 6<br>IN1 IN2<br>Safety controller<br>* 4 * 5<br>Function Setting<br>EDM EDM Disabled (factory default setting)<br>Interlock Auto Reset (factory default setting)<br>Operating Range Selection Long (factory default setting) * 7<br>Non-Muting system Perform wiring according to the wiring diagram.<br>External Test not used Connect the TEST line of the emitter to 0V/24V of the emitter.<br>Optical Synchronization Connect the COM(+) and COM(-) line of the emitter and receiver with each other.<br>Timing chart *1. Reverse the polarity of the power supply when using in the NPN system. Select a safety<br>Beam state: Unblocked controller of PNP or NPN type according to the system of your application.<br>Blocked *2. If External Test is used, refer to the User's Manual .<br>*3. Connect the line to 24V/0V (brown) of the receiver via a lockout reset switch (NC contact) if<br>OSSD Lockout Reset is used.<br>Emitter Receiver<br>2<br>* )<br>3 )<br>) * (Red (White<br>0V/24V (Blue) COM(+) (White) COM(-) (Yellow) TEST (Black) 24V/0V (Brown) 0V/24V (Blue) RESET/EDM (Yellow COM(+) (Gray) COM(-) (Pink) AUX OSSD (Black) OSSD 24V/0V (Brown)<br>**----- End of picture text -----**<br>
- *4. Refer to page 44 for more information.
- *5. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *6. This is the case for a PELV circuit.
- *7. The Intelligent Tap is needed to set the Short mode. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
**Note:** For the functional earth connection, refer to page 35.
**36**
**F3SG-SR/PG**
## **Manual Reset Mode with EDM**
## **[Wiring Example]**
**==> picture [456 x 409] intentionally omitted <==**
**----- Start of picture text -----**<br>
Intelligent Tap Needed<br>F39-JG�C-L F39-JG�C-D<br>KM1<br>KM2<br>S2 M<br>KM1 KM1 KM2<br>S1<br>KM2 Wiring for NPN * 1<br>24 VDC 24 VDC<br>* 3<br> : Indicates a switch position. : Indicates a switch position.<br>Setting<br>Function<br>DIP switch SD Manager 3<br>EDM * 4 EDM Enabled � �� [External device monitoring] : Enable<br>Interlock * 4 Manual Reset (Start/ 4 ON [Start interlock] : Enable<br>Restart Interlock) 5 ON [Restart interlock] : Enable<br>Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.<br>Operating Range Selection Long * 4 8 ON [Operating Range Selection] : Long mode * 4<br>Perform wiring according to the wiring diagram.<br>Non-Muting system N/A [Muting] : Disable * 4<br>Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). * 5<br>External Test used<br>N/A [External test signal inversion] : Disable<br>Optical Synchronization Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.<br>Emitter Receiver<br>2<br>*<br>)<br>) (Yellow ) ) y)<br>(White (Black (Brown ue)(Bl ) Gra( )(Red<br>0V/24V (Blue) Not used TEST 24V/0V /24V V0 RESET/EDM (Yellow MUTE A MUTE B (Pink) AUX OSSD 1 (Black) OSSD 2 (White) 24V/0V (Brown)<br>OPERATING RANGE SELECT INPUT<br>**----- End of picture text -----**<br>
: Indicates a switch position. : Indicates a switch position.
S1: Test switch
## Timing chart
S2: Lockout/interlock reset switch
- Beam state: Unblocked KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor Blocked M: Motor *1. Reverse the polarity of the power supply when using in the NPN system.
- Test switch (S1) *2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
- Reset switch (S2) *3. This is the case for a PELV circuit. *4. Set the function with the DIP Switches on the Intelligent Tap or the SD
- OSSD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- *1. Reverse the polarity of the power supply when using in the NPN system.
- *2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
- *5. This wiring example shows light emission stop when connected to 24 VDC with PNP setting, and light emission stop when connected to 0 VDC with NPN setting. If TEST switch is not needed, refer to the _User's Manual_ .
**Note:** For the functional earth connection, refer to page 35.
**37**
**F3SG-SR/PG**
## **Manual Reset Mode with EDM and Y-Joint Plug/Socket Connector**
## **[Wiring Example]**
|||||F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|F39-GCNY2<br>F39-JG�A-D<br>F39-JGR3K-D and F39-JG□B-D<br>KM<br>KM<br>KM1<br>KM2<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)<br>AUX (Red)<br>MUTE B(Pink)<br>Receiver|Intelligent|Tap|Needed|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||1<br>2<br>M|||
||||||||||||||24 VDC|||
|||||||||||||||||
|||||*****3<br>IN<br>PLC*****2||||||||||||
|||||||||||||||||
|||||||||||||||||
||**Function**|||**Setting**||||||||||||
|||||**DIP switch**|||||||||**SD Manager 3**|||
|EDM*4||||EDM Enabled<br>�|||||||��||[External device monitoring] : Enable|||
|Interlock*4<br> <br>||||Manual Reset (Start/<br>Restart Interlock)<br>4<br>ON<br>5<br>ON|||||||||[Start interlock] : Enable<br>[Restart interlock] : Enable|||
|||||||||||||||||
|Operating Range Selection*5<br>L<br>L||||ong (factory default setting)||||||||||||
|||||ong<br>8|||||||ON||[Operating Range Selection] : Long mode|||
|Non-Muting system<br> <br>||||Perform wiring according to the wiring diagram.||||||||||||
|||||N/A|||||||||[Muting] : Disable*4|||
|External Test not used<br>||||N/A||||||||||||
|Optical Synchronization<br>||||Connect the wires according to the diagram above.||||||||||||
: Indicates a switch position.
S1: Lockout/interlock reset switch
## Timing chart
KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor
M: Motor
Beam state: Unblocked Blocked Reset switch (S) OSSD
**==> picture [109 x 46] intentionally omitted <==**
- PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.)
- *1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC of PNP or NPN type according to the system of your application.
- *2. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. For the setting this function, refer to the _User's Manual_ .
- *3. This is the case for a PELV circuit.
- *4. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- *5. To set the Short mode, set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- **Note: 1.** When using the Y-Joint Plug/Socket Connector (F39-GCNY2), the following functions are not available. • External Test
- Operating Range Selection by wiring
- Wired Synchronization
**2.** For the functional earth connection, refer to page 35.
**38**
**F3SG-SR/PG**
## **Manual Reset Mode with Intelligent Tap**
## **[Wiring Example]**
|S1<br>IO-Link<br>Master*****5<br>F39-JG�B-L/<br>XS5F-D521-DJ0-IL<br>F39-JG�A-D<br>0V/24V(Blue)<br>MUTE B(Pink)<br>MUTE A(Gray)<br>RESET/EDM<br>(Yellow)|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-|SGIT-IL3<br>F39-JGR3K-L and<br>F39-JG□B-L<br>Emitter|SGIT-IL3<br>F39-JGR3K-L and<br>F39-JG□B-L<br>Emitter|SGIT-IL3<br>F39-JGR3K-L and<br>F39-JG□B-L<br>Emitter|SGIT-IL3<br>F39-JGR3K-L and<br>F39-JG□B-L<br>Emitter|SGIT-IL3<br>F39-JGR3K-L and<br>F39-JG□B-L<br>Emitter|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||||||
|||||||||||||||||||
||IO-Link<br>Master*****5<br>|||||||AUX (Red)|OSSD 1(Black)<br>OSSD 2(White)<br>24V/0V(Brown)|||||||||
|||||||||||||||||24 VDC||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||IN<br>PLC*****2|IN1|||IN2||||||
|||||||||||||||||||
|||**Function**||||||||||||||**Setting**||
||||||||||**DIP switch**||||||||**SD Manager 3**|
|EDM||||||||EDM Disabled<br>3<br>ON|||||||||[External device monitoring] : Disable|
|Interlock||||||||Manual Reset (Start/<br>Restart Interlock)<br>4<br>ON<br>5<br>ON|||||||||[Start interlock] : Enable<br>[Restart interlock] : Enable|
|Operating Range Selection||||||||Long<br>8<br>ON|||||||||[Operating Range Selection] : Long mode|
|Non-Muting system||||||||Perform wiring according to the wiring diagram.||||||||||
|||||||||N/A|||||||||[Muting] : Disable|
|Test Input||||||||N/A||||||||||
|Wired Synchronization||||||||Connect the emitter and receiver with the Intelligent Tap.||||||||||
|Timing chart<br>Beam state: Unblocked<br>Blocked<br>Reset switch (S)<br>OSSD||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
- *3. Refer to page 75 for more information.
- *4. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *5. For connecting with the IO-Link Master unit, refer to an instruction manual of the IO-Link Master unit you use.
- *6. This is the case for a PELV circuit.
- **Note: 1.** When using the Intelligent Tap (F39-SGIT-IL3) with the emitter and receiver connected, the following functions are not available. • External Test
- Operating Range Selection by wiring
- Optical Synchronization
**2.** For the functional earth connection, refer to page 35.
**39**
**F3SG-SR/PG**
## **Manual Reset Mode with Reset Switch Connector**
## **[Wiring Example]**
**==> picture [456 x 413] intentionally omitted <==**
**----- Start of picture text -----**<br>
Innteligent Tap Needed<br>F39-JGR3K-D<br>F39-JG�C-L F39-GCNY3<br>XS5F-D421�80-F<br>F39-JG�A-D<br>Wiring for NPN * 1<br>24 VDC<br>L1<br>S1 S2<br>24 VDC<br>* 5<br>IN1 IN2<br>Safety controller<br>* 3 * 4<br> : Indicates a switch position. : Indicates a switch position.<br>Setting<br>Function<br>DIP switch SD Manager 3<br>EDM EDM Disabled (factory default setting)<br>Interlock * 6 Manual Reset (Start/ 4 ON [Start interlock] : Enable<br>Restart Interlock) 5 ON [Restart interlock] : Enable<br>Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.<br>Operating Range Selection Long * 6 8 ON [Operating Range Selection] : Long mode * 6<br>Perform wiring according to the wiring diagram.<br>Non-Muting system N/A [Muting] : Disable * 6<br>Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). * 7<br>External Test used<br>N/A [External test signal inversion] : Disable<br>Optical Synchronization Open the COM(+) and COM(-) lines of the emitter.<br>Emitter Receiver<br>2<br>) ) * ) ) ) y) ) ) )<br>(White (Yellow (White (Brown ue)(Bl ) (Blue Gra( ) (Black (White (Brown<br>(Black (Red<br>/24V V<br>0V/24V (Blue) Not used OPERATING RANGE SELECT INPUT TEST (Black) 24V/0V (Brown) RESET 24V/0V 0 AUX 0V/24V RESET (Yellow) MUTE A MUTE B (Pink) AUX OSSD 1 OSSD 2 24V/0V<br>**----- End of picture text -----**<br>
: Indicates a switch position. : Indicates a switch position.
## Timing chart
S1: Test switch
S2: Lockout/interlock reset switch
**==> picture [66 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
Beam state: Unblocked<br>Blocked<br>Test switch (S1)<br>Reset switch (S2)<br>OSSD<br>**----- End of picture text -----**<br>
**==> picture [108 x 64] intentionally omitted <==**
L1: Lamp
- *1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC and a safety controller of PNP or NPN type according to the system of your application.
- *2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
- *3. Refer to page 75 for more information.
- *4. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *5. This is the case for a PELV circuit.
- *6. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- *7. This wiring example shows light emission stop when connected to 24 VDC with PNP setting, and light emission stop when connected to 0 VDC with NPN setting. If TEST switch is not needed, refer to the _User's Manual_ (Man. No. Z405).
- **Note: 1.** When using the Reset Switch Connector (F39-GCNY3), the following functions are not available.
- External Device Monitoring (EDM)
**2.** For the functional earth connection, refer to page 35.
**40**
**F3SG-SR/PG**
## **Double Break with EDM**
## **[Wiring Example]**
**==> picture [457 x 329] intentionally omitted <==**
**----- Start of picture text -----**<br>
Intelligent Tap Needed * 5<br>S3<br>F39-JG�C-L F39-JG�C-D<br>KM1<br>KM2<br>Cam<br>S2 M<br>KM1 S3 KM1 KM2<br>S1 KM2 Wiring for NPN * 1<br>0 VDC<br>24 VDC 24 VDC<br>* 4<br>IN<br>PLC * 3<br> : Indicates a switch position. : Indicates a switch position.<br>Setting<br>Function<br>DIP switch SD Manager 3<br>EDM - [External device monitoring] : Enable * 5<br>Operating Range Selection Short : Connect the OPERATING RANGE SELECT INPUT line of the emitter to 0 VDC.<br>PSDI N/A [PSDI] : Double break * 5<br>Perform wiring according to the wiring diagram.<br>Non-Muting system N/A [Muting] : Disable * 5<br>Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). * 6<br>External Test used<br>N/A [External test signal inversion] : Disable<br>Optical Synchronization Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.<br>Emitter Receiver<br>2<br>) ) * ) ) )<br>) ) )<br>0V/24V (Blue (WhiteNot used (Yellow TEST (Black 24V/0V (Brown 0V/24V (Blue RESET/EDM )(Yellow GraPSDI y)( (PinkNot used )(RedAUX OSSD 1 (Black OSSD 2 (White) 24V/0V (Brown)<br>OPERATING RANGE SELECT INPUT<br>**----- End of picture text -----**<br>
: Indicates a switch position. : Indicates a switch position.
S1: Test switch S2: Reset switch S3: Press position switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.) M: Motor
- *1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC of PNP or NPN type according to the system of your application.
- *2. Open or connect the line to 24 VDC if Operating Range Selection is used in Long Mode.
- *3. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. For the setting this function, refer to the _User's Manual_ (Man.No.Z405).
- *4. This is the case for a PELV circuit.
- *5. Set the function with the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- *6. This wiring example shows light emission stop when connected to 24 VDC with PNP setting, and light emission stop when connected to 0 VDC with NPN setting. If TEST switch is not needed, refer to the _User's Manual_ (Man. No. Z405).
**==> picture [394 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
Timing chart<br>Reset switch (S2)<br>Press position switch (S3)<br>Dummybreak Feedingparts Removingparts Feedingparts Unintendedblock Dummybreak * Dummybreak *<br>Unblocked<br>Blocked<br>OSSD<br>T1 T2 T3 T4 T5 T2 T3 T4 T1 T2 T3 T4 T5<br>min. min. min. min. min. min. min. min. min. min. min. min. min.<br>T6 Machine stops Machine restarts<br>**----- End of picture text -----**<br>
T1: Minimum pressing time of reset switch. Configurable from 100 to 500 ms in 100-ms increments by SD Manager 3.
- T2: Minimum break time (300 ms)
- T3: Minimum unblocked time during the time from removing to feeding parts. T3 = T1
- T4: Minimum break time (300 ms)
- T5: Minimum pressing time of press position switch. T5 = T1
- T6: Wait time until double break is complete (30 s or less)
- When the machine is stopped by unintended block in the middle of pressing of parts, operation of the reset switch (S1) and then double dummy break are needed for reinitiation of the machine cycle.
**Note:** For the functional earth connection, refer to page 35.
**41**
**F3SG-SR/PG**
## **Muting System Wiring Examples Standard Muting Mode/Exit-Only Muting mode**
## **[Wiring Example]**
|**uting System Wiring Examples**<br>**ndard Muting Mode/Exit-Only Muting mode**<br>**ring Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**|**ng System Wiring Examples**<br>**ard Muting Mode/Exit-Only Muting mode**<br>**g Example]**||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|F39-JG�C-L<br>F39-JG�C-D<br>24 VDC<br>Wiring for NPN*****1<br>24 VDC<br>S3<br>S4<br>*****4<br>IN<br>PLC*****5<br>*****8<br>IN1<br>Safety controller<br>*****6*****7<br>IN2<br>S1<br>S2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2(White)<br>24V/0V(Brown)<br>OPERATING RANGE<br>SELECT INPUT (Yellow)*****2<br>TEST (Black)<br>Not used(White)<br>24V/0V (Brown)<br>0V/24V(Blue)<br>0V/24V (Blue)<br>AUX (Red)<br>MUTE B(Pink)<br>MUTE A (Gray)<br>RESET/EDM<br>(Yellow) *****3<br>S1: Test switch<br>S2:Lockout reset switch, override switch or override cancel switch<br>S3, S4: Muting sensor<br>PLC: Programmable logic controller (Used for monitoring only.<br>NOT related to safety system.)<br>Intelligent Tap<br>Needed*****9<br>: Indicates a switch position.|F39-JG�C-L<br>F39-JG�C-D<br>24 VDC<br>S3<br>S4<br>*****4<br>IN<br>PLC*****5<br>*****8<br>IN1<br>Safety controller<br>*****6*****7<br>IN2<br>S1<br>S2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2(White)<br>24V/0V(Brown)<br>OPERATING RANGE<br>SELECT INPUT (Yellow)*****2<br>TEST (Black)<br>Not used(White)<br>24V/0V (Brown)<br>0V/24V(Blue)<br>AUX (Red)<br>MUTE B(Pink)<br>MUTE A (Gray)<br>RESET/EDM<br>(Yellow) *****3<br>1: Test switch<br>2:Lockout reset switch, override switch or override cancel switch<br>3, S4: Muting sensor<br>LC: Programmable logic controller (Used for monitoring only.<br>NOT related to safety system.)<br>Intelligent Tap|||||||Intelligent Tap||||Needed*****9|
||||||||||||||
|||||||||||24 VDC|||
||||||||||||||
||||||||||||||
||IN<br>PLC*****5<br>*****8<br>IN1<br>Safety controller<br>*****6*****7<br>IN2<br>1: Test switch<br>2:Lockout reset switch, override switch or override cancel switch<br>3, S4: Muting sensor<br>LC: Programmable logic controller (Used for monitoring only.<br>NOT related to safety system.)||||||||||||
||||||||||||||
||||||||||||||
|**Function**|||**Setting**||||||||||
||||**DIP switch**|||||||**SD Manager 3**|||
|EDM|||EDM Disabled (factory default setting)||||||||||
||||-||||[External device|||monitoring] : Disable*9|||
|Interlock|||Auto Reset (factory default setting)||||||||||
||||-||||[Start interlock] : Disable<br>[Restart interlock] : Disable*9||||||
|Operating Range Selection|||Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.||||||||||
||||-||||[Operating Range Selection] : Long mode*9||||||
|Standard Muting Mode|||When not using the Intelligent Tap or the SD Manager 3, perform wiring according to the wiring diagram.<br>(factory default setting)||||||||||
||||N/A||||[Muting] : Enable<br>[Muting mode] : Standard Muting (Installation<br>Example1/2)*9||||||
|Exit-Only Muting Mode|||N/A||||[Muting] : Enable<br>[Muting mode] : Exit-Only Muting*9||||||
|External Test used|||Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact).*10||||||||||
||||N/A||||[External test signal inversion] : Disable||||||
|Optical Synchronization|||Open the COM(+) and COM(-) lines of the emitter.||||||||||
- *1. Reverse the polarity of the power supply when using in the NPN system.
## Timing chart
**==> picture [470 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Beam state: Unblocked *2. Connect the line to 0 VDC if Operating Range Selection is used<br>Blocked in Short Mode.<br>*3. Also used as OVERRIDE INPUT line.<br>Test switch (S1) *4. Make sure to connect an override cancel switch to the RESET<br>line when using the override function. Otherwise the override<br>MUTE A state may not be released by the override cancel switch,<br>resulting in serious injury.<br>MUTE B *5. When connecting to the PLC, the output mode must be<br>changed with the SD Manager 3 according to your application.<br>OSSD For the setting this function, refer to the User's Manual<br>(Man.No.Z405).<br>**----- End of picture text -----**<br>
- *2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
- *6. Refer to page 75 for more information.
- *7. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *8. This is the case for a PELV circuit.
- *9. Set the function with the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to the wiring diagram.
- *10. This wiring example shows light emission stop when connected to 24 VDC with PNP setting, and light emission stop when connected to 0 VDC with NPN setting. If TEST switch is not needed, refer to the _User's Manual_ (Man. No. Z405).
**Note:** For the functional earth connection, refer to page 35.
**42**
**F3SG-SR/PG**
## **Standard Muting Mode/Exit-Only Muting mode with Intelligent Tap**
## **[Wiring Example]**
|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-JG�B-L/<br>XS5F-D521-DJ0-IL|F39-SGI|F39-SGI|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|*****8<br>T-IL3<br>24 VDC<br>F39-JGR3K-L and F39-JG□B-L<br>F3<br>F3<br>IN1<br>Safety controller<br>*****5*****6<br>IN2<br>Receiver<br>Emitter<br>OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|IO-Link<br>Master*****7<br>||||||AUX (Red)||OSSD 1 (Black)<br>OSSD 2 (White)<br>24V/0V (Brown)||||||||||
|||||||||||||||||24 VDC||
|||||||||||||||||||
|||||||||||||||||||
||||||PL|||||||||||||
|||||||IN||IN1|||IN2|||||||
|||||||C*****4||||||||||||
|||||||||||||||||||
||**Function**|||||||||||||||**Setting**||
|||||||||**DIP switch**|||||||||**SD Manager 3**|
|EDM||||||EDM Disabled<br>3<br>ON|||||||||||[External device monitoring] : Disable|
|Interlock||||||Auto Reset<br>4<br>ON<br>5<br>ON|||||||||||[Start interlock] : Disable<br>[Restart interlock] : Disable|
|Operating Range Selection||||||Long<br>8|||||||||ON||[Operating Range Selection] : Long mode|
|Standard Muting Mode||||||N/A|||||||||||[Muting] : Enable<br>[Muting mode] : Standard Muting (Installation<br>Example1/2)|
|Exit-Only Muting Mode||||||N/A|||||||||||[Muting] : Enable<br>[Muting mode] : Exit-Only Muting|
|Test Input||||||N/A||||||||||||
|Wired Synchronization||||||Connect the emitter and receiver with the Intelligent Tap.||||||||||||
|MUTE A<br>MUTE B<br>OSSD<br>Timing chart<br>Beam state: Unblocked<br>Blocked||||||||S1: Lockout reset switch, override switch or override cancel switch<br>S2, S3: Muting sensor<br>PLC:Programmable logic controller (Used for monitoring only. NOT<br>related to safety system.)<br>*1. Reverse the polarity of the power supply when using in<br>the NPN system. Select a PLC and a safety controller of<br>PNP or NPN type according to the system of your<br>application.<br>*2. Also used as OVERRIDE INPUT line.<br>*3. Make sure to connect an override cancel switch to the<br>RESET line when using the override function. Otherwise<br>the override state may not be released by the override<br>cancel switch, resulting in serious injury.||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
: Indicates a switch position.
- *4. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. For the setting this function, refer to the _User's Manual_ (Man.No.Z405).
- *5. Refer to page 75 for more information.
- *6. The safety controller and the F3SG-SR must share the power supply or be connected to the common terminal of the power supply.
- *7. For connecting with the IO-Link Master unit, refer to an instruction manual of the IO-Link Master unit you use.
- *8. This is the case for a PELV circuit.
**Note: 1.** When using the Intelligent Tap (F39-SGIT-IL3), the following functions are not available.
- External Test
- Operating Range Selection by wiring
- Optical Synchronization
**2.** For the functional earth connection, refer to page 35.
**43**
**F3SG-SR/PG**
## **Connectable Safety Control Units**
The F3SG-SR in the PNP system can be connected to the safety control units listed in the table below.
|**Connectable safety control units (PNP output)**|**Connectable safety control units (PNP output)**|**Connectable safety control units (PNP output)**|
|---|---|---|
|G9SA-301<br>G9SA-321-T<br>G9SA-501<br>G9SB-200-B<br>G9SB-200-D<br>G9SB-301-B<br>G9SB-301-D<br>G9SE-201<br>G9SE-401<br>G9SE-221-T<br>F3SP-T01|G9SX-AD322-T<br>G9SX-ADA222-T<br>G9SX-BC202<br>G9SX-GS226-T15|G9SP-N10S<br>G9SP-N10D<br>G9SP-N20S<br>NE0A-SCPU01<br>NE1A-SCPU01<br>NE1A-SCPU02<br>DST1-ID12SL-1<br>DST1-MD16SL-1<br>DST1-MRD08SL-1<br>NX-SIH400<br>NX-SID800<br>GI-SMD1624<br>GI-SID1224|
The F3SG-SR in the NPN system can be connected to the safety control unit listed in the table below.
**Connectable safety control units (NPN output)** G9SA-301-P
For the connection to IO-Link with the Intelligent Tap, the F3SG-SR can be connected to the IO-Link Master unit listed in the table below.
**Connectable IO-Link Master units** *
NX-ILM400 GX-ILM08C
* Connectable to units supporting IO-Link Version 1.1.
**44**
**F3SG-SR/PG Input/Output Circuit**
## **Entire Circuit Diagram**
The entire circuit diagrams of the F3SG-SR are shown below. The numbers in the circles indicate the connector's pin numbers.
## **F3SG-SR**
**==> picture [461 x 492] intentionally omitted <==**
**----- Start of picture text -----**<br>
ABI Indicator PNP/NPN select<br>input circuit Brown 24V/0V<br>1<br>Test input 2 Black TEST<br>circuit<br>Emitter<br>main circuit Communication 4 White COM(+)<br>circuit<br>Operating Range Select<br>Operating range 5 [Yellow] Input/COM(-)<br>select input circuit<br>Blue<br>3<br>PNP/NPN select Brown<br>input circuit 2<br>RESET/EDM<br>Reset input 1 Yellow<br>circuit<br>Muting input 4 Pink MUTE B/COM(-)<br>circuit B<br>Communication<br>circuit<br>Muting input circuit A 3 Gray MUTE A/PRE-RESET/PSDI/COM(+)<br>Receiver<br>White OSSD 2<br>main circuit 2 6<br>Load<br>Black OSSD 1<br>5<br>Receiver<br>main circuit 1<br>Load<br>Red AUX<br>ABI 8<br>Load<br>Blue 0V/24V<br>7<br>Indicator<br>**----- End of picture text -----**<br>
**45**
**F3SG-SR/PG**
## **Input Circuit Diagram by Function**
The input circuit diagrams of by function are shown below.
## **Test Input**
<Light emission stops when connected to 24 VDC>
**==> picture [225 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 VDC<br>Short circuit<br>current<br>Emitter Approx. 5.0 mA<br>main circuit<br>0 VDC<br>**----- End of picture text -----**<br>
<Light emission stops when connected to 0 V>
**==> picture [226 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 VDC<br>Emitter<br>Short circuit<br>main circuit<br>current<br>Approx. 6.0 mA<br>0 VDC<br>**----- End of picture text -----**<br>
## **Operating Range Select Input**
**==> picture [226 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
<Long><br>+24 VDC<br>5 V<br>Short circuit<br>current<br>Emitter<br>main circuit Approx. 4.2 mA<br>0 VDC<br>**----- End of picture text -----**<br>
## <Short>
**==> picture [226 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 VDC<br>5 V<br>Emitter<br>main circuit<br>Short circuit<br>current<br>Approx. 4.2 mA<br>0 VDC<br>**----- End of picture text -----**<br>
## **RESET/EDM, MUTE A/B**
<PNP>
**==> picture [222 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 VDC<br>Short circuit<br>current * 1<br>Receiver<br>main circuit<br>0 VDC<br>**----- End of picture text -----**<br>
- 1. Short circuit current: approx. 9.5 mA (RESET/EDM), approx. 4.5 mA (MUTE A/B)
## <NPN>
**==> picture [137 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
Receiver<br>main circuit<br>**----- End of picture text -----**<br>
**==> picture [130 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 VDC<br>Short circuit<br>current * 2<br>0 VDC<br>**----- End of picture text -----**<br>
- 2. Short circuit current: approx. 13.0 mA (RESET/EDM), approx. 7.0 mA (MUTE A/B)
**46**
**F3SG-SR/PG**
**Dimensions**
**(Unit: mm)**
## **F3SG-SR Series**
## **Mounted with Side-Mount Brackets (Intermediate Brackets) (F39-LSGF) Backside Mounting**
**==> picture [451 x 516] intentionally omitted <==**
**----- Start of picture text -----**<br>
46.7<br> 38 32<br>Side-Mont<br>Bracket<br>(F39-LSGF)<br>2-M5<br>or M6<br>Side-Mont<br>Bracket<br>(F39-LSGF)<br>2-M5<br>or M6<br><Screw: M5 or M6><br>Dimension C 4-digit number of the type name (Protective height: )<br>F3SG-SR-14<br>C-20<br>F3SG-SR-25<br>Dimension D<br>F3SG-SR-45<br>C-40<br>F3SG-SR-85<br>F3SG-F3SG-SRSR-14-25 1020 Protective height (Dimension C) Number of Side-Mount Bracket * Dimension F<br>Dimension P<br>F3SG-SR-45 40 0160 to 1440 2 1000 mm max.<br>F3SG-SR-85 80 1520 to 2480 3 1000 mm max.<br> 6.3 dia.<br> 250 max.<br> 250 max.<br> 5.7<br> F<br> D F C<br> C(Protective height)<br> 34.4<br>5.7 5.7<br> 250 max. P 250 max.<br> 10<br> 50<br>**----- End of picture text -----**<br>
- The number of brackets required to mount either one of emitter and receiver. The side-mount brackets (intermediate brackets) are included with the light curtain.
**47**
**F3SG-SR/PG**
## **Side Mounting**
**==> picture [306 x 412] intentionally omitted <==**
**----- Start of picture text -----**<br>
50<br> 38 32<br>Side-Mont<br>Bracket<br>(F39-LSGF)<br>2-M5<br>or M6<br>Side-Mont<br>Bracket<br>(F39-LSGF)<br>2-M5<br>or M6<br> 19.4<br><Screw: M5 or M6><br> 46.7<br>6.3 dia.<br> 250 max. 250 max.<br> 8.2<br> F<br> D F C<br> C(Protective height)<br> 8.2 8.2<br> 250 max. P 250 max.<br> 10<br>**----- End of picture text -----**<br>
|**Dimension C**|4-digit number of the type name (Protective height:|4-digit number of the type name (Protective height:|)||||
|---|---|---|---|---|---|---|
|**Dimension D**|F3SG-SR-14|C-20|||||
||F3SG-SR-25||||||
||F3SG-SR-45|C-40|||||
||F3SG-SR-85||||||
|**Dimension P**|F3SG-SR-14|10||**Protective height**<br>**(Dimension C)**|**Number of Side-Mount**<br>**Bracket***|**Dimension F**|
||F3SG-SR-25|20|||||
||F3SG-SR-45|40||0160 to 1440|2|1000 mm max.|
||F3SG-SR-85|80||1520 to 2480|3|1000 mm max.|
- The number of brackets required to mount either one of emitter and receiver. The side-mount brackets (intermediate brackets) are included with the light curtain.
**48**
**F3SG-SR/PG**
## **Mounted with Adjustable Side-Mount Brackets (Intermediate Brackets) (F39-LSGA) Backside Mounting**
|||||250 max.<br>250 max.<br>F<br>46.<br> <br>38<br>ective height:)<br>C-20<br>C-40<br>10<br>20<br>40<br>80<br>**Prote**<br>**(Dim**<br>016<br>032<br>152|10<br>P<br>D<br>250 max.<br>F<br>250 max.<br>C<br>56.5<br>4<br>56.5<br><Screw: M5 or M6><br>7<br>C(Protective height)<br>32<br>50<br>2-M5<br>or M6<br>2-M5<br>or M6|10<br>P<br>D<br>250 max.<br>F<br>250 max.<br>C<br>56.5<br>4<br>56.5<br><Screw: M5 or M6><br>7<br>C(Protective height)<br>32<br>50<br>2-M5<br>or M6<br>2-M5<br>or M6|10<br>P<br>D<br>250 max.<br>F<br>250 max.<br>C<br>56.5<br>4<br>56.5<br><Screw: M5 or M6><br>7<br>C(Protective height)<br>32<br>50<br>2-M5<br>or M6<br>2-M5<br>or M6|
|---|---|---|---|---|---|---|---|
||56.5<br> <br>6.3<br>73<br>20<br>Adjustable<br>Side-Mount<br>Bracket<br>(F39-LSGA)<br>Adjustable<br>Side-Mount<br>Bracket<br>(F39-LSGA)<br>4|||||||
|||||||||
|||||||||
|||56.5<br>6.3|73|||||
|||||||||
|||||||||
|||||||||
|**Dimension C**<br>4-d|igit number of the type name (Prot|||ective height:)||||
|**Dimension D**|F3SG-SR-14|||C-20||||
||F3SG-SR-25|||||||
||F3SG-SR-45|||C-40||||
||F3SG-SR-85||||**ctive height**<br>**ension C)**|**Number of Adjustable**<br>**Side-Mount Bracket ***|**Dimension F**|
|**Dimension P**|F3SG-SR-14|||10||||
||F3SG-SR-25|||20|0 to 0280|1|1000 mm max.|
||F3SG-SR-45|||40|0 to 1440|2|1000 mm max.|
||F3SG-SR-85|||80|0 to 2480|3|1000 mm max.|
* The number of brackets required to mount either one of emitter and receiver.
**49**
**F3SG-SR/PG**
## **Side Mounting**
**==> picture [322 x 409] intentionally omitted <==**
**----- Start of picture text -----**<br>
50<br> 38 32<br>Adjustable<br>Side-Mount<br>Bracket<br>(F39-LSGA) 2-M5<br>or M6<br>Adjustable<br>Side-Mount<br>Bracket<br>(F39-LSGA) 23.5 2-M5<br> 10 or M6<br><Screw: M5 or M6><br> 46.7<br> 250 max. 250 max.<br> 56.5<br> F<br> D F C<br> C(Protective height)<br> 6.3<br> 73 56.5 56.5<br> 250 max. P 250 max.<br> 10<br>**----- End of picture text -----**<br>
|**Dimension C**|4-digit number of the type name (Protective height:)|4-digit number of the type name (Protective height:)|**Protective height**<br>**(Dimension C)**<br>**Number of Adjustable**<br>**Side-Mount Bracket***<br>**Dimension F**<br>0160 to 0280<br>1<br>1000 mm max.<br>0320 to 1440<br>2<br>1000 mm max.<br>1520 to 2480<br>3<br>1000 mm max.|**Protective height**<br>**(Dimension C)**<br>**Number of Adjustable**<br>**Side-Mount Bracket***<br>**Dimension F**<br>0160 to 0280<br>1<br>1000 mm max.<br>0320 to 1440<br>2<br>1000 mm max.<br>1520 to 2480<br>3<br>1000 mm max.|**Protective height**<br>**(Dimension C)**<br>**Number of Adjustable**<br>**Side-Mount Bracket***<br>**Dimension F**<br>0160 to 0280<br>1<br>1000 mm max.<br>0320 to 1440<br>2<br>1000 mm max.<br>1520 to 2480<br>3<br>1000 mm max.|
|---|---|---|---|---|---|
|**Dimension D**|F3SG-SR-14|C-20||||
||F3SG-SR-25|||||
||F3SG-SR-45|C-40||||
||F3SG-SR-85|||**Number of Adjustable**<br>**Side-Mount Bracket***|**Dimension F**|
|**Dimension P**|F3SG-SR-14|10||||
||F3SG-SR-25|20||1|1000 mm max.|
||F3SG-SR-45|40||2|1000 mm max.|
||F3SG-SR-85|80||3|1000 mm max.|
* The number of brackets required to mount either one of emitter and receiver.
**50**
**F3SG-SR/PG**
## **Mounted with Adjustable Top/Bottom Brackets (F3SJ, F3SN Adapter) (F39-LSGTB-SJ) and Side-Mount Brackets (Intermediate Brackets) (F39-LSGF) Backside Mounting**
**==> picture [482 x 597] intentionally omitted <==**
**----- Start of picture text -----**<br>
46.7<br> 32<br> 3.2 19<br> 1.7 19<br>Adjustable 38 4-M5 2-M8<br>Top/Bottom<br>Bracket<br>(F39-LSGTB-SJ)<br> 12<br>Side-Mont<br>Bracket<br>(F39-LSGF) 2-M5 2-M5<br>or M6 or M6<br>Adjustable<br>Top/Bottom<br>Bracket 19<br>(F39-LSGTB-SJ)<br><Screw for Adjustable <Screw for Adjustable<br>Top/Bottom Bracket: M5 * 1> Top/Bottom Bracket: M8 * 1><br>Dimension C 4-digit number of the type name (Protective height: )<br>F3SG-SR-14<br>C-20<br>F3SG-SR25<br>Dimension D<br>F3SG-SR-45<br>C-40<br>F3SG-SR-85<br>Dimension G C+27.2+N1+N2<br>Dimension H C+38+N1+N2<br>Dimension I C+58+N1+N2<br>Dimension N1 0 to 30 * 2 Number of Number of<br>Dimension N2 0 to 30 * 2 Protective height Adjustable Intermediate Dimension F<br>F3SG-SR-14 10 (Dimension C) Top/Bottom Bracket * 3 Bracket * 3 * 4<br>F3SG-SR-25 20 0160 to 0840 2 0 ---<br>Dimension P<br>F3SG-SR-45 40 0880 to1680 2 1 1000 mm max.<br>F3SG-SR-85 80 1760 to 2480 2 2 1000 mm max.<br>9 dia.<br>6.3 dia.<br> 5.8<br> N1<br> F F F<br> I H G D C G C H<br> 34.4<br> 5.7 5.7 5.7<br>C(Protective height)<br> P<br> N2<br> 10<br> 50<br>**----- End of picture text -----**<br>
- *1. Side-Mount Bracket: M5 or M6
- *2. For the model of protective height of 0160, the numbers corresponding to dimensions N1 and N2 are 20 to 30.
- *3. The number of brackets required to mount either one of emitter and receiver.
- *4. The side-mount brackets (intermediate brackets) are included with the light curtain.
**51**
**F3SG-SR/PG**
## **Side Mounting**
**==> picture [428 x 437] intentionally omitted <==**
**----- Start of picture text -----**<br>
50<br> 38<br> 19 3.2<br> 19<br> 1.7 32 2-M8<br>4-M5<br>Adjustable Top/Bottom<br>Bracket (F39-LSGTB-SJ)<br>Side-Mont Bracket<br>(F39-LSGF)<br>2-M5 2-M5<br>or M6 or M6<br>Adjustable Top/Bottom<br>Bracket (F39-LSGTB-SJ)<br> 19<br><Screw for Adjustable <Screw for Adjustable<br>Top/Bottom Bracket: M5 * 1> Top/Bottom Bracket: M8 * 1><br> 46.7<br>9 dia.<br>6.3 dia.<br> 5.8<br> N1<br> F F F<br> G H I D C G C H<br> 34.4<br> 8.2 8.2<br> 8.2<br> C(Protective height)<br> P<br> N2<br> 10<br>**----- End of picture text -----**<br>
|**Dimension C**|4-digit number of the type name (Protective height:)|4-digit number of the type name (Protective height:)|**Prote**<br>**(Dim**<br>016<br>088<br>176|||||
|---|---|---|---|---|---|---|---|
|**Dimension D**|<br>F3SG-SR-14<br>F3SG-SR25|<br>C-20||||||
||F3SG-SR-45|C-40||||||
||F3SG-SR-85|||||||
|**Dimension G**|C+27.2+N1+N2|||||||
|**Dimension H**|C+38+N1+N2|||||||
|**Dimension I**|C+58+N1+N2|||||||
|**Dimension N1**|0 to 30*2|||**ctive height**<br>**ension C)**|**Number of**<br>**Adjustable**<br>**Top/Bottom**<br>**Bracket*3**|**Number of**<br>**Intermediate**<br>**Bracket*3*4**|**Dimension F**|
|**Dimension N2**|0 to 30*2|||||||
|**Dimension P**|F3SG-SR-14|10||||||
||F3SG-SR-25|20||0 to 0840|2|0|---|
||F3SG-SR-45|40||0 to1680|2|1|1000 mm max.|
||F3SG-SR-85|80||0 to 2480|2|2|1000 mm max.|
- *1. Side-Mount Bracket: M5 or M6
- *2. For the model of protective height of 0160, the numbers corresponding to dimensions N1 and N2 are 20 to 30.
- *3. The number of brackets required to mount either one of emitter and receiver.
- *4. The side-mount brackets (intermediate brackets) are included with the light curtain.
**52**
**F3SG-SR/PG**
## **Mounted with Adjustable Top/Bottom Brackets (F3SJ, F3SN Adapter) (F39-LSGTB-SJ) and Adjustable Side-Mount Brackets (Intermediate Brackets) (F39-LSGA) Backside Mounting**
**==> picture [487 x 570] intentionally omitted <==**
**----- Start of picture text -----**<br>
46.7<br> 32<br> 3.2 19 19<br>Adjustable 38 1.7 4-M5 2-M8<br>Top/Bottom Bracket<br>(F39-LSGTB-SJ)<br> 12<br>Adjustable<br>Side-Mount Bracket<br>(F39-LSGA)<br> 20 2-M5 2-M5<br> 4 or M6 or M6<br> 4 4<br>Adjustable<br>Top/Bottom Bracket 19<br>(F39-LSGTB-SJ)<br><Screw for Adjustable <Screw for Adjustable<br>Top/Bottom Bracket: M5 * 1> Top/Bottom Bracket: M8 * 1><br>Dimension C 4-digit number of the type name (Protective height: )<br>F3SG-SR-14<br>C-20<br>F3SG-SR25<br>Dimension D<br>F3SG-SR-45<br>C-40<br>F3SG-SR-85<br>Dimension G C+27.2+N1+N2<br>Dimension H C+38+N1+N2<br>Dimension I C+58+N1+N2<br>Dimension N1 0 to 30 * 2 Number of<br>Number of<br>Dimension N2 0 to 30 * 2 Protective height Adjustable Intermediate Dimension F<br>F3SG-SR-14 10 (Dimension C) Top/Bottom Bracket * 3 Bracket * 3<br>F3SG-SR-25 20 0160 to 0840 2 0 ---<br>Dimension P<br>F3SG-SR-45 40 0880 to1680 2 1 1000 mm max.<br>F3SG-SR-85 80 1760 to 2480 2 2 1000 mm max.<br> 5.8 9 dia.<br> N1<br> F F F<br> 6.3<br> 56.5 73 I H G D 56.5 C G 56.5<br> C H<br> C(Protective height)<br> P<br> N2<br> 10<br> 50<br>**----- End of picture text -----**<br>
- *1. Adjustable Side-Mount Bracket: M5 or M6
- *2. For the model of protective height of 0160, the numbers corresponding to dimensions N1 and N2 are 20 to 30.
- *3. The number of brackets required to mount either one of emitter and receiver.
**53**
**F3SG-SR/PG**
## **Side Mounting**
**==> picture [481 x 599] intentionally omitted <==**
**----- Start of picture text -----**<br>
50<br> 38<br> 19<br> 19<br>Adjustable Top/Bottom 1.7 3.2 32 4-M5 2-M8<br>Bracket (F39-LSGTB-SJ)<br>Adjustable Side-Mount 4.2<br>Bracket (F39-LSGA) 10 2-M5 2-M5<br>or M6 or M6<br> 4.2 4.2<br>Adjustable Top/Bottom<br>Bracket (F39-LSGTB-SJ)<br> 19<br><Screw for Adjustable <Screw for Adjustable<br>Top/Bottom Bracket: M5 * 1> Top/Bottom Bracket: M8 * 1><br> 46.7<br>Dimension C 4-digit number of the type name (Protective height: )<br>F3SG-SR-14<br>C-20<br>F3SG-SR25<br>Dimension D<br>F3SG-SR-45<br>C-40<br>F3SG-SR-85<br>Dimension G C+27.2+N1+N2<br>Dimension H C+38+N1+N2<br>Dimension I C+58+N1+N2<br>Dimension N1 0 to 30 * 2 Number of Number of<br>Dimension N2 0 to 30 * 2 Protective height Adjustable Intermediate Dimension F<br>F3SG-SR-14 10 (Dimension C) Top/Bottom Bracket * 3 Bracket * 3<br>F3SG-SR-25 20 0160 to 0840 2 0 ---<br>Dimension P<br>F3SG-SR-45 40 0880 to1680 2 1 1000 mm max.<br>F3SG-SR-85 80 1760 to 2480 2 2 1000 mm max.<br>9 dia.<br> 5.8<br> N1<br> F F F<br> 6.3<br> 73 56.5 G H I D 56.5 C G 56.5 C H<br> C(Protective height)<br> P<br> N2<br> 10<br>**----- End of picture text -----**<br>
- *1. Adjustable Side-Mount Bracket: M5 or M6
- *2. For the model of protective height of 0160, the numbers corresponding to dimensions N1 and N2 are 20 to 30.
- *3. The number of brackets required to mount either one of emitter and receiver.
**54**
**F3SG-SR/PG**
## **Accessories**
## **Bracket Side-Mount Bracket (Intermediate Bracket) (F39-LSGF)**
**==> picture [276 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
13<br> 5.7<br> 8.2<br> 13<br> 34.4 41 Material: Zinc alloy<br>6.3 dia.<br>6.3 dia.<br> 30.7 14.7<br> 30.7 6.5 37.5<br> 12<br>**----- End of picture text -----**<br>
## **Adjustable Side-Mount Bracket (Intermediate Bracket) (F39-LSGA, sold separately)**
**==> picture [182 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.3<br> 13<br> 56.5<br> 73<br> 6.3<br> 13<br> 56.5 Material: Zinc alloy<br> 26.7 20<br>44.1<br> 10<br> 12 38.5<br> 26.5<br>**----- End of picture text -----**<br>
## **Adjustable Top/Bottom Bracket (F3SJ, F3SN Adapter) (F39-LSGTB-SJ, sold separately)**
**==> picture [169 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
12<br> 32<br> 4.6<br>3.2 1.7<br> 47.7 19<br> 32<br>9 dia.<br> 137<br> 5.8<br> 29<br> 10 15.4<br>**----- End of picture text -----**<br>
Material: High rolled steel (SPHC)
**55**
**F3SG-SR/PG**
## **Adjustable Top/Bottom Bracket (F3SG-RA/RE Adapter) (F39-LSGTB-RE, sold separately)**
**==> picture [194 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 32<br> 4.6<br> 3.2<br> 15<br> 47.7<br> 20<br>R3.3<br>R4.1<br> 147.2<br> 39.2<br> 22.2 9.5<br>**----- End of picture text -----**<br>
Material: High rolled steel (SPHC)
## **Adjustable Top/Bottom Bracket (MS4800, F3SR Adapter) (F39-LSGTB-MS, sold separately)**
**==> picture [182 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
12<br> 32<br> 4.6<br> 3.2<br> 47.7<br>38.1<br>52.8<br>R3.4 R3.4<br>R3.4<br> 154<br> 46<br> 23.2 18.4<br>**----- End of picture text -----**<br>
Material: High rolled steel (SPHC)
**56**
**F3SG-SR/PG**
## **Intelligent Tap Intelligent Tap (F39-SGIT-IL3, sold separately)**
**==> picture [422 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
87 2-M4<br><Screw: M4><br>30<br>17.5 M12 IP67 16 75 11.9 M12 IP67 17.5<br>connector connector<br>CN2<br>CN1<br>CN3 CN4<br>M12 IP67 41 M12 IP67<br>connector<br>87 connector<br>97 Material: PBT resin (Body parts)<br>40 40 .43<br>23.4 2<br>4.5 4.5<br>19.5<br>3 3<br>**----- End of picture text -----**<br>
## **Intelligent Tap Bracket (F39- LITF1, sold separately)**
**==> picture [426 x 284] intentionally omitted <==**
**----- Start of picture text -----**<br>
111<br>97<br>87 (105)<br>2-M4<br>Mounting dimensions to DIN track<br>30.3 31.8<br>47.8<br>Material: PBT resin (Body parts)<br>40<br>9.7<br>4<br>16<br>**----- End of picture text -----**<br>
**57**
**F3SG-SR/PG**
## **Assembly Dimensions (Intelligent Tap/ Intelligent Tap Bracket)**
**==> picture [390 x 229] intentionally omitted <==**
**----- Start of picture text -----**<br>
<Mounting on DIN track><br>75<br>Intelligent Tap F39-SGIT-IL3<br>30.3 Intelligent Tap Bracket<br>47.8 F39-LITF1<br>111<br>Material: PBT resin (Body parts)<br>40<br>39.7<br>4<br>**----- End of picture text -----**<br>
## **Bluetooth[®] Communication Unit (F39-SGBT, sold separately)**
**==> picture [254 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
19.7 40.7<br>Material: PBT resin (Body parts)<br>31.9<br>**----- End of picture text -----**<br>
## **Assembly Dimensions (Intelligent Tap/Bluetooth[®] Communication Unit/Intelligent Tap Bracket)**
Bluetooth[®] Communication Unit F39-SGBT
**==> picture [322 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
40<br>75 Intelligent Tap 31.9<br>40.7 F39-SGIT-IL3 2<br>30.3<br>Intelligent Tap Bracket<br>47.8<br>F39-LITF1<br>111<br>)<br>9.4<br>(<br>30 49.1<br>**----- End of picture text -----**<br>
**58**
**F3SG-SR/PG**
## **Spatter Protection Cover**
**Spatter Protection Cover (F39-HSG** **, sold separately)**
**==> picture [486 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Assembly Dimensions<br>34.2<br>L<br>11.1<br>L = @@@@ Material: PC resin (Transparent cover)<br>ABS resin (Side wall)<br>34.2<br>42.8<br>**----- End of picture text -----**<br>
## **Connecting cable**
## **Root-Straight Cable**
**Root-Straight Cable for Emitter (F39-JG** **C-L, sold separately)**
**==> picture [474 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-M2.5 screw 16.4 L<br>31.6 Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5, 5-wire<br>Connector (Cross section of conductor: 0.3 mm [2] /insulator diameter: dia. 1.1 mm/AWG24)<br>18.5<br>**----- End of picture text -----**<br>
**Root-Straight Cable for Receiver (F39-JG** **C-D, sold separately)**
|3||18.5<br>2-M2.5 screw|16.|L<br>4|L<br>4||
|---|---|---|---|---|---|---|
|||18.5|||||
||1.6||||||
||||||||
|||||**Receiver cable (Black)**<br>**Length (L)**<br>**F39-JG3C-D**<br>3 m<br>**F39-JG7C-D**<br>7 m<br>**F39-JG10C-D**<br>10 m|||
||**Emitter**|**cable (Gray)**||**Receiver cable (Black)**|**Length (L)**||
|**F39-JG3C-L**||||**F39-JG3C-D**|3 m||
|**F39-JG7C-L**||||**F39-JG7C-D**|7 m||
|**F39-JG10C-L**||||**F39-JG10C-D**|10 m||
## **Root-Plug Cable for Extended**
**Root-Plug Cable for Extended for Emitter (F39-JGR** **K-L, sold separately)**
**==> picture [454 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 Connector<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5, 5-wire<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Root-Plug Cable for Extended for Receiver (F39-JGR-Plug Cable for Extended for Receiver (F39-JGR K-D, sold separately)<br>2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 Connector<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5, 8-wire<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR3K-L F39-JGR3K-D 0.3 m<br>18.5<br>14.9 dia.<br>18.5<br>14.9 dia.<br>**----- End of picture text -----**<br>
**Root-Plug Cable for Extended for Receiver (F39-JGR-Plug Cable for Extended for Receiver (F39-JGR** **K-D, sold separately)**
**59**
**F3SG-SR/PG**
## **Extended Socket-Straight Cable**
**Extended Socket-Straight Cable for Emitter (F39-JG** **A-L, sold separately)**
**==> picture [5 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>**----- End of picture text -----**<br>
**==> picture [411 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
40.7<br>Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 5-wire<br>M12 IP67 connector (Cross section of conductor: 0.32 mm [2] /insulator diameter: dia. 1.2 mm/AWG22)<br>14.9 dia.<br>**----- End of picture text -----**<br>
## **Extended Socket-Straight Cable for Receiver (F39-JG** **A-D, sold separately)**
**==> picture [5 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>**----- End of picture text -----**<br>
|14.9 dia.||Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 8-wire<br>(Cross section of conductor: 0.32 mm2/insulator diameter: dia. 1.2 mm/AWG22)<br>12 IP67 connector<br>40.7|Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 8-wire<br>(Cross section of conductor: 0.32 mm2/insulator diameter: dia. 1.2 mm/AWG22)<br>12 IP67 connector<br>40.7|Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 8-wire<br>(Cross section of conductor: 0.32 mm2/insulator diameter: dia. 1.2 mm/AWG22)<br>12 IP67 connector<br>40.7|
|---|---|---|---|---|
||M||||
|||**able (Gray)**<br>**Receiver cable (Black)**<br>**Length (L)**<br>**F39-JG3A-D**<br>3 m<br>**F39-JG10A-D**<br>10 m|||
||**Emitter c**|**able (Gray)**|**Receiver cable (Black)**|**Length (L)**|
|**F39-JG3A-L**|||**F39-JG3A-D**|3 m|
|**F39-JG10A-L**|||**F39-JG10A-D**|10 m|
## **Extended Plug-Socket Cable**
**Extended Plug-Socket Cable for Emitter: Cable for extension (F39-JG** **B-L, sold separately)**
**==> picture [454 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>44.7 40.7<br>M12 IP67 connector M12 IP67 connector<br>Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 5-wire (2-pair + 1)<br>(Cross section of conductor: 0.32 mm [2] /insulator diameter: dia. 1.2 mm)<br>14.9 dia. 14.9 dia.<br>**----- End of picture text -----**<br>
## **Extended Plug-Socket Cable for Receiver: Cable for extension (F39-JG** **B-D, sold separately)**
**==> picture [451 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>44.7 40.7<br>M12 IP67 connector M12 IP67 connector<br>Insulated vinyl round cable, dia. 6.6, minimum bending radius R36, 8-wire (4-pair)<br>(Cross section of conductor: 0.32 mm [2] /insulator diameter: dia. 1.2 mm)<br>14.9 dia. 14.9 dia.<br>**----- End of picture text -----**<br>
|**Emitter cable**|**(Gray)**<br>**Receiver cable (Black)**|**Length (L)**|
|---|---|---|
|**F39-JG3B-L**|**F39-JG3B-D**|3 m|
|**F39-JG10B-L**|**F39-JG10B-D**|10 m|
|**F39-JG20B-L**|**F39-JG20B-D**|20 m|
**60**
**F3SG-SR/PG**
## **Cascading Cable for Extended (F39-JGR3W, sold separately) (two cables per set, one for emitter and one for receiver)**
**==> picture [453 x 269] intentionally omitted <==**
**----- Start of picture text -----**<br>
Emitter Cascading Cable for Extended<br>2-M2.5 screw 16.4 300 40.7<br>31.6<br>M12 IP67 Connector<br>Connector<br>Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5, 5-wire<br>(Cross section of conductor: 0.2 mm [2] /<br>insulator diameter: dia. 1.1 mm)<br>Receiver Cascading Cable for Extended<br>2-M2.5 screw 16.4 300 40.7<br>31.6<br>M12 IP67 Connector<br>Connector<br>Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5, 8-wire<br>(Cross section of conductor: 0.2 mm [2] /<br>insulator diameter: dia. 1.1 mm)<br>Set model name Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR3W F39-JGR3W-L F39-JGR3W-D 0.3 m<br>18.5<br>14.9 dia.<br>18.5<br>14.9 dia.<br>**----- End of picture text -----**<br>
**Side-by-side Cascading Cable (F39-JGR12L, sold separately) (two cables per set, one for emitter and one for receiver)**
**==> picture [455 x 383] intentionally omitted <==**
**----- Start of picture text -----**<br>
Side-by-side Cascading Cable for Emitter<br>2-M2.5 screw 16.4 120 16.4 2-M2.5 screw<br>31.6<br>31.6<br>Connector Connector<br>BTM side Oil-resistant PVC-insulated round cable, dia. 6 TOP side<br>minimum bending radius R5, 5-wire<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Side-by-side Cascading Cable for Receiver<br>2-M2.5 screw 16.4 120 16.4 2-M2.5 screw<br>31.6<br>31.6<br>Connector Connector<br>BTM side Oil-resistant PVC-insulated round cable, dia. 6 TOP side<br>minimum bending radius R5, 8-wire<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Set model name Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR12L F39-JGR12L-L F39-JGR12L-D 12 cm<br>Conversion Cable<br>F3SJ-B/A Conversion Cable for Emitter (F39-JGR3K-SJ-L, sold separately)<br>2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 8-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>18.5 18.5<br>18.5 18.5<br>18.5<br>14.9 dia.<br>**----- End of picture text -----**<br>
**61**
**F3SG-SR/PG**
## **F3SJ-B/A Conversion Cable for Receiver (F39-JGR3K-SJ-D, sold separately)**
**==> picture [455 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 8-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR3K-SJ-L F39-JGR3K-SJ-D 0.3 m<br>F3SG-RE Conversion Cable for Emitter (F39-JGR3K-RE-L, sold separately)<br>2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 4-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>18.5<br>14.9 dia.<br>18.5<br>14.9 dia.<br>**----- End of picture text -----**<br>
## **F3SG-RE Conversion Cable for Receiver (F39-JGR3K-RE-D, sold separately)**
**==> picture [455 x 387] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 4-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR3K-RE-L F39-JGR3K-RE-D 0.3 m<br>MS48 Conversion Cable for Emitter (F39-JGR3K-MS-L, sold separately)<br>2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 5-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>MS48 Conversion Cable for Receiver (F39-JGR3K-MS-D, sold separately)<br>2-M2.5 screw 16.4 300 44.7<br>31.6<br>M12 IP67 connector, 8-wire<br>Connector Oil-resistant PVC-insulated round cable, dia. 6<br>minimum bending radius R5<br>(Cross section of conductor: 0.2 mm [2] /insulator diameter: dia. 1.1 mm)<br>Emitter cable (Gray) Receiver cable (Black) Length<br>F39-JGR3K-MS-L F39-JGR3K-MS-D 0.3 m<br>18.5<br>14.9 dia.<br>18.5<br>14.9 dia.<br>18.5<br>14.9 dia.<br>**----- End of picture text -----**<br>
**62**
**F3SG-SR/PG**
## **Y-Joint Plug/Socket Connector (F39-GCNY2, sold separately)**
**==> picture [493 x 199] intentionally omitted <==**
**----- Start of picture text -----**<br>
Plug marked with (blue circle): Connect to control panel side<br>Socket marked with (open circle): Connect to emitter<br>15.0<br>17.7 45.5<br>CN2 40.7<br>To control<br>panel side<br>To receiver<br>To emitter<br>CN1 Insulated vinyl round cable, dia. 6 M12 x 1<br>minimum bending radius R36<br>M12 IP67 connector,<br>8-wire M12 IP67 connector, M12 IP67 connector, 8-wire<br>5-wire<br>500<br>Material: PBT (Main body)<br>Model Length<br>F39-GCNY2 0.5 m<br>4.6 dia.<br>35.0<br>**----- End of picture text -----**<br>
## **Reset Switch Connector (F39-GCNY3, sold separately)**
Plug marked with (blue circle): Connect to control panel side Plug marked with (open circle): Connect to reset switch side
**==> picture [462 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 IP67 connector, 8-wire Insulated vinyl round cable, dia. 6<br>minimum bending radius R36<br>17.6 45.5<br>15.0<br>40.7<br>CN2<br>To control<br>panel side CN3<br>CN1 To receiver<br>To reset<br>switch side M12 IP67 connector, 8-wire<br>500<br>M12 IP67 connector, 4-wire<br>Material: PBT (Main body)<br>4.6 dia.<br>35.0<br>**----- End of picture text -----**<br>
|**Model**|**Length**|
|---|---|
|**F39-GCNY3**|0.5 m|
## **Connector Connected to Cable, Socket on One Cable End (XS5F-D421- @ 80-F, sold separately)**
|.9 dia.|||40.7<br>L|(Cable length)|30|30|
|---|---|---|---|---|---|---|
||||||||
||||||||
||||M12 IP6|Insulated vin<br>7 connector, 4-wire|||
|**Model**|**Length (L)**|
|---|---|
|**XS5F-D421-C80-F**|1 m|
|**XS5F-D421-D80-F**|2 m|
|**XS5F-D421-E80-F**|3 m|
|**XS5F-D421-G80-F**|5 m|
|**XS5F-D421-J80-F**|10 m|
|**XS5F-D421-L80-F**|20 m|
**63**
**F3SG-SR/PG**
## **Troubleshooting**
## **F3SG-SR**
## **LOCKOUT State**
Identify an error according to the combination of the indicators when the error occurs. See the following troubleshooting tables to take measures. For detail, Refer to _User’s Manual_ .
Illuminated Blink
## <Indicator status at lockout: Receiver>
## Combination of indicators and error description
**==> picture [499 x 358] intentionally omitted <==**
**----- Start of picture text -----**<br>
ERR indicator MAINT indicator Other indicators Error description<br>O<br>or Safety Output error<br>OSSD<br>P<br>Error due to change of PNP/NPN<br>E or<br>or PNP polarity during operation<br>ERR<br>Blinking once F Blanking monitoring error<br>or Configuration error<br>[Error description] CFG Parameter error<br>Recoverable error<br>M<br>or TOP Cap error<br> * 1 Other sensor error<br>MAINT<br>Red blinking : Replacement-recommended error<br>BTM DIP Switch setting error<br>E * 2<br>or<br>ERR<br>O<br>Safety output error due to power<br>Blinking twice or supply voltage or noise<br>OSSD<br>E Communication error<br>or --- External device monitoring error<br>ERR Error other than those above<br>Blinking once<br>M<br>--- or Orange blinking --- Intelligent Tap error<br>MAINT<br>**----- End of picture text -----**<br>
- 1. For F3SG-SRA, the Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
- 2. For F3SG-SRA, the Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
## <Indicator status at lockout: Emitter>
Combination of indicators and error description
|ERR indicator|Other indicators|Other indicators|Other indicators|Error description|
|---|---|---|---|---|
|E<br>or<br>ERR<br>Blinking once|L<br>or<br>LONG|||Operating range selection setting error|
||TOP<br>*****1*****3|||Cap error<br>Other sensor error|
||*****2*****3<br>BTM|||DIP Switch setting error|
||||||
||||||
||||||
||---|||Communication error<br>Error other than those above|
- 1. For F3SG-SRA, the Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
- 2. For F3SG-SRA, the Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
- 3. The indicator blinks only in the case the Wired Synchronization is enabled and is off in the case the Optical Synchronization is enabled.
**64**
**F3SG-SR/PG**
|**Description**|**Checking by**|**Checking by**|**Error code**<br>**(HEX)**<br>*1|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3**<br>**Mobile APP**|||
|Safety output error|X|X|60, 6B, 6C|The OSSD lines may be short-circuited to each other or<br>another signal line may be short-circuited to the OSSD<br>line.<br>Wire the OSSD lines properly.|
||||56|The polarity does not match between the power supply<br>and the OSSD lines.<br>Check if a correct polarity is selected for the PNP/NPN<br>setting according to your application. Also check:<br>• if the power supply (0 VDC or 24 VDC) of the Intelligent<br>Tap and F3SG-SR is wired as intended.<br>• if the OSSD lines are properly wired.|
|Recoverable error|X|---|---|The error may occur due to a temporary cause. Identify the<br>cause by the status of the other LED indicator and take<br>measures.|
|Replacement-recommended error||||The error may occur due to a product failure. If the<br>measure according to the status of the other LED indicator<br>does not work, it is recommended to replace the F3SG-<br>SR.|
|Intelligent Tap error|X|---|---|An error due to noise may have occurred in the internal<br>circuit of the Intelligent Tap.<br>Check the noise level in the environment.|
|||||The internal circuit of the Intelligent Tap may be defective.<br>Replace the Intelligent Tap.|
|Error due to change of PNP/NPN<br>polarity during operation|X|X|E7|An error due to noise may have occurred in the internal<br>circuit.<br>Check the noise level in the environment.|
|||||The internal circuit may be defective.<br>Replace the F3SG-SR.|
|Blanking monitoring error|X|X|EC|An error is detected by the Fixed Blanking Monitoring<br>function or the Floating Blanking Monitoring function.|
|Configuration error|X|X|39, 3A, 3B|The cascading cable may be short-circuited, broken, or<br>disconnected. Check that the cascading cable should be<br>tightly connected. If the cascading cable is broken, replace<br>it.|
|||||The number of connected sensors or beams may have<br>exceeded the maximum value due to cascading.<br>Check the configuration.|
||||3C, 3E, 3F|A model name does not match between emitter and<br>receiver. Check that the emitter and receiver are the same<br>model.|
||||34|An error may have occurred to the internal information of<br>the model name of the F3SG-SR due to effect of noise.<br>If other devices using the same power supply generate<br>noise, do not share the same power supply with other<br>devices, and use a separate power supply exclusively for<br>the safety components.<br>The inductive noise tends to be induced especially if the<br>power supply line of the machine guarded and the power<br>supply line of the Intelligent Tap are arranged in parallel.<br>Arrange the exclusive power supply near the Intelligent<br>Tap or lay the power supply line of the Intelligent Tap away<br>from the power supply line of the machine guarded.<br>If the power supply for the Intelligent Tap is located near<br>the power supply of the machine guarded and it shares the<br>same grounding wire, it is subject to the influence of<br>common mode noise.<br>Separate the grounding point or use it as the exclusive<br>ground.|
|||||An error may have occurred in the internal circuit.<br>Replace the F3SG-SR.|
|Parameter error|X|X|F1|The settings do not match between the Intelligent Tap and<br>F3SG-SR. Perform the Backup.|
||||40|The settings of the F3SG-SR may be faulty. Check if the<br>settings are correct.|
*1. You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
**65**
**F3SG-SR/PG**
|**Description**|**Checking by**|**Checking by**|**Error code**<br>**(HEX)**<br>*1|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3**<br>**Mobile APP**|||
|Cap error|X|X|4F|A cap may be detached. Attach the cap properly.|
|Other sensor error|X|X|38|Other sensor being cascaded caused an error. Check the<br>indicator of the sensor.|
|DIP Switch setting error|X|X|E7, E8|A DIP Switch on the Intelligent Tap setting may have been<br>changed during operation.<br>Check if a DIP Switch setting was changed or not.|
|Communication error|---|X|30, 32|The communication lines or other lines may be short-<br>circuited or broken.<br>Check if the cascading or extension cables. If the<br>cascading cable or extension cables is broken, replace it.|
||||31|An error may have occurred to the communication due to<br>effect of noise.<br>If other devices using the same power supply generate<br>noise, do not share the same power supply with other<br>devices, and use a separate power supply exclusively for<br>the safety components.<br>The inductive noise tends to be induced especially if the<br>power supply line of the machine guarded and the power<br>supply line of the Intelligent Tap are arranged in parallel.<br>Arrange the exclusive power supply near the Intelligent<br>Tap or lay the power supply line of the Intelligent Tap away<br>from the power supply line of the machine guarded.<br>If the power supply for the Intelligent Tap is located near<br>the power supply of the machine guarded and it shares the<br>same grounding wire, it is subject to the influence of<br>common mode noise.<br>Separate the grounding point or use it as the exclusive<br>ground.|
|||||An error may have occurred in the internal circuit.<br>Replace the F3SG-SR.|
|Safety output error due to power<br>supply voltage or noise|X|X|19|The power supply voltage may have dropped temporarily<br>when the F3SG-SR is in operation. Check for temporary<br>power supply voltage drop (by about 12 VDC) by the<br>influence of the inductive load, etc.<br>If the exclusive power supply is not used, check the power<br>consumption of other connected devices for enough<br>capacity.|
|||||Power supply voltage may be outside the rated range.<br>Connect the F3SG-SR to a 24 VDC±20% power supply<br>voltage.|
|||||Voltage fluctuation may have occurred due to insufficient<br>power supply capacity.<br>Replace the power supply with one that has a larger<br>capacity.|
|||||Instantaneous break or instantaneous stop may have<br>occurred due to power sharing with other devices. Do not<br>share the power supply with other devices. Connect the<br>F3SG-SR to a power supply that is dedicated to electro-<br>sensitive protective devices for electro-sensitive protective<br>equipment such as the F3SG-SR, safety controller, etc.|
||||1A|Effect of noise may be excessive.<br>If other devices using the same power supply generate<br>noise, do not share the same power supply with other<br>devices, and use a separate power supply exclusively for<br>the safety components.<br>The inductive noise tends to be induced especially if the<br>power supply line of the machine guarded and the power<br>supply line of the F3SG-SR are arranged in parallel.<br>Arrange the exclusive power supply near the F3SG-SR or<br>lay the power supply line of the F3SG-SR away from the<br>power supply line of the machine guarded.<br>If the power supply for the F3SG-SR is located near the<br>power supply of the machine guarded and it shares the<br>same grounding wire, it is subject to the influence of<br>common mode noise.<br>Separate the grounding point or use it as the exclusive<br>ground.|
*1. You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
**66**
**F3SG-SR/PG**
|**Description**|**Checking by**|**Checking by**|**Error code**<br>**(HEX)**<br>*1|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3**<br>**Mobile APP**|||
|Operating range selection setting<br>error|X|X|EB|The setting of the operating range selection may be<br>incorrect.<br>• When the Intelligent Tap is connected, check if the<br>Operating Range Selection of the DIP Switch is<br>properly set.<br>• When the Intelligent Tap is not connected, check if the<br>Operating Range Select Input line is properly wired.|
|External device monitoring error|---<br>*2|X|52|Relay may be welded. Replace the relay.|
|||||The relay and the RESET line may not be properly wired.<br>Check the wiring with the relay.|
|||||The relay response time may be exceeding the allowable<br>delay time. Change the allowable delay time or replace the<br>relay with one that has an appropriate response time.|
|Error other than those above|---<br>*2|X|Error code<br>other than<br>those above|An error may have occurred in the internal circuit.<br>Replace the F3SG-SR.|
- *1. You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
- *2. Other indicators than the ERR and MAINT indicators are not illuminated. For details of the error, refer to [Code] and [Error description] displayed in [Error Log] in the SD Manager 3.
**67**
**F3SG-SR/PG**
## **Warning**
Identify an error according to the combination of the indicators when the error occurs. See the following troubleshooting tables to take measures. For detail, Refer to _User’s Manual_ .
Illuminated
Blinking OFF
<Indicator status at warning: Receiver ***** 1>
Combination of indicators and error description
|ERR indicator|MAINT indicator|Other indicators|Error description|
|---|---|---|---|
|E<br>or<br>ERR|M<br>or<br>MAINT|S<br>or<br>SEQ<br>F<br>or<br>CFG|Teach-in error|
||Orange<br>M<br>or<br>MAINT|*****2<br>S<br>or<br>SEQ|Muting sequence error,<br>Interlock sequence error<br>or PSDI sequence error|
|||Area Beam<br>Indicator<br>Green|Malfunction due to<br>ambient light or vibration|
|||Area Beam<br>Indicator<br>Orange<br>After 5 to 10 s|Low incident light level|
- *1. In the warning state, no indicators on the emitter are illuminated or blink.
- *2. There are several illumination patterns to identify a faulty sequence.
|**Description**|**Checking by**|**Checking by**|**Warning**<br>**code (HEX)**<br>***1**|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3 Mobile APP**|||
|Teach-in error|X|X|ED|Teach-in failed. Perform the Teach-in again.|
|Muting sequence error|X|X|2C, 2D, 2F|Muting input may have been applied in the incorrect order.<br>Check the pattern of illumination of the LED indicator to<br>identify the cause.|
|Interlock sequence error|X|---|---|When using the Pre-Reset function, the reset signals for<br>interlock may be input in the wrong order. Check the pattern of<br>illumination of the LED indicator to identify the cause.|
|PSDI sequence error|X|X|2A, 2B|PSDI input may have been applied in the correct order. Check<br>if the pattern of illumination of the LED indicator to identify the<br>cause.|
|Malfunction due to<br>ambient light or vibration|X|X<br>(SD Manager 3 Mobile<br>APP is not applicable)<br>*2|---|Malfunction may have occurred due to ambient light or<br>instantaneous beam misalignment from vibration. Check the<br>installation condition.|
|Low incident light level|X|X|12|The incident light level may be low due to dirty front window or<br>misaligned beams caused by vibration.<br>Clean the front window and check the alignment of the beams.|
|Low communications<br>quality|---<br>*3|X|F0|Retries of communications may have been generated due to<br>noise. Check the noise level in the proximity of the<br>communication lines.|
|||||Retries of communications may have been generated due to<br>short-circuit of the communication lines. Check the cables<br>connected.|
- *1. You can check the warning codes by SD Manager 3 or SD Manager 3 Mobile APP.
- *2. You can check by instantaneous block detection logs in [Instantaneous Block Detection Information].
- *3. The indicators are not illuminated. For details of the warning, refer to [Code] and [Warning description] displayed in [Warning Log] in the SD Manager 3.
**68**
**F3SG-SR/PG**
## **Muting Sequence Error Indication**
The following table is applied only when the muting function is being enabled.
|**SEQ indicator**|**Cause and measures**|
|---|---|
|Blinking: Once|Power supply may have been turned ON with muting input A or B being ON.<br>Check the condition of the muting sensors and the F3SG-SR.|
||Muting input B may have been turned ON before muting input A was turned ON.<br>Check the condition of the muting sensors.|
||Muting input A and B may have been turned ON at the same time.<br>• Check the arrangement of the muting sensors.<br>• Check if the wiring of muting input A and B is short-circuited.|
||Either muting input A or B may have been turned ON with the F3SG-SR being blocked or INTERLOCK State.<br>Check the condition of the F3SG-SR.|
|Blinking: Twice|Muting input B may have been turned ON within T1min (= 0.1 s *) after muting input A was turned ON.<br>• Check that if the muting sensors are installed too close each other.<br>• Check that if the speed of the workpiece is too fast.|
||It may have taken T1max (= 4 s*) or longer for muting input B to be turned ON after muting input A was turned<br>ON.<br>• Check that if the muting sensors are installed too far each other.<br>• Check that if the speed of the workpiece is too slow.|
||The F3SG-SR may have been blocked after muting input A was turned ON but before muting input B was<br>turned ON.<br>Check the condition of the F3SG-SR.|
|Blinking: Four times|The F3SG-SR may have been blocked within 0.08 s after muting input A and B were normally turned ON.<br>• Check that if the muting sensor and the F3SG-SR are installed too close each other.<br>• Check that if the speed of the workpiece is too fast.|
||Muting may have been released after the F3SG-SR entered the MUTING state but before a workpiece blocked<br>the F3SG-SR.<br>• Check that the workpiece still remains.<br>• Check that the speed of the workpiece is too slow.|
|Blinking: Five times|The F3SG-SR entered the MUTING state, but muting may have then been released while a workpiece passes<br>through the F3SG-SR.<br>• Check that the workpiece still remains.<br>• Check that if the speed of the workpiece is too slow.<br>• Check that the muting sensors have been installed upstream and downstream of the F3SG-SR with the size<br>of workpieces taken into account. (Using four muting sensors)|
|Blinking: Six times|Muting may have been released with muting input A and B remained ON after a workpiece passed through the<br>F3SG-SR.<br>• Check that the workpiece still remains.<br>• Check that the speed of the workpiece is too slow.|
|Blinking: Seven times|The next muting sequence may have started after muting was released but before the initial muting condition<br>was established.<br>• Check that if a next workpiece has not entered before the current workpiece passes through the F3SG-SR.<br>• Check that if the interval between workpieces are too narrow.|
* Factory default setting
## **Interlock Sequence Error Indication**
The following table is applied only when the pre-reset function is being enabled.
|**SEQ indicator**|**Cause and measures**|
|---|---|
|Blinking: Once|The reset or pre-reset switch may have been pressed before the F3SG-SR receives light.<br>Check the wiring of the reset and pre-reset signals.|
||The F3SG-SR may have been blocked or the pre-reset switch may have been pressed before the pre-reset<br>switch is pressed.<br>Check the status of the F3SG-SR and the wiring of the pre-reset signal.|
|Blinking: Twice|After the pre-reset switch was pressed, the pre-reset or reset switch may have been pressed before the F3SG-<br>SR is blocked.<br>Check the installation environment of the F3SG-SR.|
|Blinking: Three times|After the pre-reset switch was pressed and the F3SG-SR was blocked, the pre-reset switch may have been<br>pressed before the reset switch is pressed.<br>Check the wiring of the pre-reset signal.|
||After the pre-reset switch was pressed, a time period from the block of the F3SG-SR to the press of the reset<br>switch may have exceeded the allowable time.<br>Check the installation environment of the F3SG-SR as well as pre-reset and reset switches.|
||The number of blocks of the F3SG-SR may have exceeded the allowable value after the pre-reset switch was<br>pressed and before the reset switch is pressed.<br>Check the installation environment of the F3SG-SR.|
**69**
**F3SG-SR/PG**
## **PSDI Sequence Error Indication**
The following table is applied only when the PSDI function is being enabled.
|**SEQ indicator**|**Error**<br>**condition**|**Cause and measures**|
|---|---|---|
|Blinking: Once||Power supply may have been turned ON with PSDI input being OFF.<br>Check the condition of the light curtains and PSDI input wiring.|
|||Power supply may have been turned ON with the light curtain blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||Power supply may have been turned ON with RESET input being OFF.<br>Check the condition of the light curtains and RESET input wiring.|
|||PSDI input may have been turned OFF before RESET input was turned OFF.<br>Check the PSDI input wiring.|
|||The light curtain may have been blocked before RESET input was turned ON.<br>Check the condition of the light curtains and RESET input wiring.|
|||The PSDI input may have turned OFF while the RESET input is OFF.<br>Check the condition of the light curtains and PSDI input wiring.|
|||The light curtain may have been blocked before RESET input was turned ON.<br>Check the condition of the light curtains and RESET input wiring.|
|Blinking: Twice||After RESET input , the light curtain may not be blocked longer than T2 and the PSDI input may<br>have turned OFF.<br>Check the condition of the light curtains and RESET input wiring.|
|||The PSDI input may have turned OFF with the light curtain blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||PSDI input may have turned OFF before the light curtain blocked twice.<br>Check the condition of the light curtains and PSDI input wiring.|
|Blinking: Three times||The light curtain was blocked before the PSDI input turned OFF.<br>Check the condition of the light curtains and PSDI input wiring.|
|||The light curtain was blocked while the PSDI input turned OFF.<br>Check the condition of the light curtains and PSDI input wiring.|
|Blinking: Four times||PSDI input may have turned OFF during the period from when the PSDI state is canceled until the<br>light curtain blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||The PSDI input may have turned OFF with the light curtain blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||It may have taken T4 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain<br>blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||It may have taken T6 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain<br>blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||The PSDI input may have turned OFF again before the light curtain blocked.<br>Check the condition of the light curtains and PSDI input wiring.|
|||It may have taken T6 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain<br>blocked twice.<br>Check the condition of the light curtains and PSDI input wiring.|
|||PSDI input may have turned OFF before the light curtain blocked again.<br>Check the light curtain status and PSDI input wiring.|
Notations ...Single Break ...Double Break ...Common
**70**
**F3SG-SR/PG**
## **Intelligent Tap**
If the Intelligent Tap detects any failure, it transitions to the LOCKOUT state. Under the LOCKOUT state, the ERR indicator is turned ON. Identify an error according to the combination of the indicators when the error occurs. See the following troubleshooting tables to take measures. For detail, Refer to _User’s Manual_ .
Illuminated OFF Fast blinking Slow blinking
## Combination of indicators and error description
|ERR<br>(Red)|ERR<br>(Red)|ERR<br>(Red)|IN<br>(Yellow)|IN<br>(Yellow)|IN<br>(Yellow)|OUT<br>(Green/Red)|OUT<br>(Green/Red)|IO-Link<br>(Green)|IO-Link<br>(Green)|Error description|
|---|---|---|---|---|---|---|---|---|---|---|
||||---|||---||---||Communication error<br>DIP Switch circuit error at startup|
|||||||||---||Communication error in Backup|
||||||||||||
||||||||||||
||||||||||||
|||||||Green||---||Communication error in Restoration|
||||||||||||
||||||||||||
||||||||||||
|||||||Red||---||Communication error between the<br>F3SG-SR and the Intelligent Tap|
||||||||||||
||||||||||||
||||||||||||
|||||||||---||Restoration failed|
||||||||||||
||||||||||||
||||||||||||
|||||||Red||---||LOCKOUT state of the F3SG-SR|
|||||||||||IO-Link circuit error|
||||||||||||
||||---|||---|||||
||||||||||||
||||---|||---||---||Power supply voltage error, or<br>other errors|
||||||||||||
||||||||||||
||||||||||||
**Note: 1.** The signals output to IO-Link or IN and OUT indicators show the statuses of the F3SG-SR or Intelligent Tap except their LOCKOUT state. **2.** The muting inputs A and B are kept in the OFF state when the LOCKOUT state occurs due to the power supply voltage error.
|**Description**|**Checking by**|**Checking by**|**Error**<br>**code**<br>**(HEX)***|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3**<br>**Mobile APP**|||
|Communication<br>error|X|X|1D|The communication lines or other lines may be short-circuited or broken.<br>Check the cables for cascading or extension cables.<br>If the wiring is extended with cables other than specified, the cables used for<br>extension may not have performance equivalent or greater than the specified<br>cables. Use cables with the same performance or more than the specified<br>cables.|
|Communication<br>error in Backup|X|X|1E|The communication lines or other lines may be short-circuited or broken.<br>Check the cables for cascading or extension cables.<br>If the wiring is extended with cables other than specified, the cables used for<br>extension may not have performance equivalent or greater than the specified<br>cables. Use cables with the same performance or more than the specified<br>cables.|
|||||Effect of noise may be excessive.<br>If other devices using the same power supply generate noise, do not share the<br>same power supply with other devices, and use a separate power supply<br>exclusively for the safety components.<br>The inductive noise tends to be induced especially if the power supply line of the<br>machine guarded and the power supply line of the Intelligent Tap are arranged<br>in parallel.<br>Arrange the exclusive power supply near the Intelligent Tap or lay the power<br>supply line of the Intelligent Tap away from the power supply line of the machine<br>guarded.<br>If the power supply for the Intelligent Tap is located near the power supply of the<br>machine guarded and it shares the same grounding wire, it is subject to the<br>influence of common mode noise.<br>Separate the grounding point or use it as the exclusive ground.|
|||||The internal circuit of the Intelligent Tap may be defective.<br>Replace the Intelligent Tap.|
**71**
**F3SG-SR/PG**
|**Description**|**Checking by**|**Checking by**|**Error**<br>**code**<br>**(HEX)***|**Cause and measures**|
|---|---|---|---|---|
||**Indicator**|**SD Manager 3/**<br>**SD Manager 3**<br>**Mobile APP**|||
|Communication<br>error in<br>Restoration|X|X|1F|The communication lines or other lines may be short-circuited or broken.<br>Check the cables for cascading or extension cables.<br>If the wiring is extended with cables other than specified, the cables used for<br>extension may not have performance equivalent or greater than the specified<br>cables. Use cables with the same performance or more than the specified<br>cables.|
|||||Effect of noise may be excessive.<br>If other devices using the same power supply generate noise, do not share the<br>same power supply with other devices, and use a separate power supply<br>exclusively for the safety components.<br>The inductive noise tends to be induced especially if the power supply line of the<br>machine guarded and the power supply line of the Intelligent Tap are arranged<br>in parallel.<br>Arrange the exclusive power supply near the Intelligent Tap or lay the power<br>supply line of the Intelligent Tap away from the power supply line of the machine<br>guarded.<br>If the power supply for the Intelligent Tap is located near the power supply of the<br>machine guarded and it shares the same grounding wire, it is subject to the<br>influence of common mode noise.<br>Separate the grounding point or use it as the exclusive ground.|
|||||The internal circuit of the Intelligent Tap may be defective.<br>Replace the Intelligent Tap.|
|Communication<br>error between<br>the F3SG-SR<br>and the<br>Intelligent Tap|X|---|---|The F3SG-SR may be disconnected from the Intelligent Tap, the communication<br>line of the F3SG-SR may be broken, or the internal circuit of the Intelligent Tap<br>may be defective. Check the connection and cable wiring between the Intelligent<br>Tap and the F3SG-SR. In the case of defective internal circuit, replace the<br>Intelligent Tap.|
|F3SG-SR<br>LOCKOUT state|X|---|---|The F3SG-SR is in the LOCKOUT state. For details of the error of the F3SG-SR,<br>check the indicator status or error code of the F3SG-SR.|
|Restoration<br>failed|X|---|---|The sensor configuration (sensor model, connection configuration, etc.) that the<br>Intelligent Tap stored by Backup does not match the sensor configuration of the<br>connected the F3SG-SR. Connect the F3SG-SR with the same sensor<br>configuration as the Backup sensor configuration. Error codes are not recorded.|
|Power supply<br>voltage error, or<br>other errors|X|X|A3|The muting inputs A and B are kept in the OFF state when the LOCKOUT state<br>occurs due to the power supply voltage error.<br>The power supply voltage may have dropped temporarily when the F3SG-SR is<br>in operation. Check for temporary power supply voltage drop (by about 12 VDC)<br>by the influence of the inductive load, etc.<br>If the exclusive power supply is not used, check the power consumption of other<br>connected devices for enough capacity.|
|||||Power supply voltage may be outside the rated range.<br>Connect the F3SG-SR to a 24 VDC±20% power supply voltage.|
|||||Voltage fluctuation may have occurred due to insufficient power supply capacity.<br>Replace the power supply with one that has a larger capacity.|
|||||Instantaneous break or instantaneous stop may have occurred due to power<br>sharing with other devices. Do not share the power supply with other devices.<br>Connect the F3SG-SR to a power supply that is dedicated to electro-sensitive<br>protective devices for electro-sensitive protective equipment such as the F3SG-<br>SR, safety controller, etc.|
|DIP Switch<br>circuit error at<br>startup|X|X|BC|The internal circuit may be defective.<br>Replace the Intelligent Tap.|
|IO-Link circuit<br>error|X|X|BD|The internal circuit may be defective.<br>Replace the Intelligent Tap.|
|Internal error|X|X|Others|The internal circuit may be defective.<br>Replace the Intelligent Tap.|
* You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
**72**
**F3SG-SR/PG**
## **Bluetooth[®] Communication Unit**
See the following troubleshooting table to take measures if any of the phenomena in the table occurs when in the connection with the BluetoothR Communication Unit.
|**Status**|**Measures**|
|---|---|
|Communications cannot be established|Check if Bluetooth®Communication Unit is properly mounted.|
||Check if Bluetooth®function is enabled on the device you use for SD Manager 3.|
||Check if Bluetooth®Communication Unit is not being paired with another device.|
||Check if Bluetooth®Communication Unit and the device you use for SD Manager 3 are properly<br>paired (or the connection is verified).*|
||Check if Bluetooth®function of the device you use for SD Manager 3 supports SPP (Serial Port<br>Profile).|
||Check if a COM port is properly configured.|
||Check the noise level in the environment.|
||Check if there is any device that uses 2.4 GHz band.|
||Check if there is any obstruction between Bluetooth®Communication Unit and the device you use<br>for SD Manager 3. The maximum permissible line-of-sight distance is approximately 10 m.|
||The F3SG-SR is under the SETTING state. Turn OFF and ON the power of the F3SG-SR.|
|Files cannot be read from the outside while<br>the sensor is connected|The sensor model in the saved file does not match the sensor model in the file that you are about to<br>read in. Check the sensor model.|
||If a file is saved by SD Manager 3 of a newer version than your SD Manager 3, the file is not usable<br>on your SD Manager 3. Check the SD Manager 3 version.|
|F3SG-SR does not go back to normal state<br>after terminating SD Manager 3|Restart F3SG-SR. If SD Manager 3 does not operate normally even after restarted, use the setup<br>recovery function to restore to the factory default settings again.|
* The procedure depends on the device you use for SD Manager 3. Refer to instruction manuals of the device.
## **Related Manuals**
|**Man.No.**|**Model**|**Manual Name**|
|---|---|---|
|Z405|F3SG-SR--|Safety Light Curtain F3SG-SRSeries User's Manuals|
- The Bluetooth[®] word mark and logo are registered trademarks and are owned by the Bluetooth SIG, Inc. and any use of such mark by OMRON Corporation is under license.
- USB Type-C™ is a trademark of USB Implementers Forum.
- The product photographs and figures that are used in this catalog may vary somewhat from the actual products.
- Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
**73**
**OMRON AUTOMATION AMERICAS HEADQUARTERS •** Chicago, IL USA **•** 847.843.7900 **•** 800.556.6766 **•** automation.omron.com
## **OMRON CANADA, INC. • HEAD OFFICE**
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com
## **OMRON ELECTRONICS DE MEXICO • HEAD OFFICE**
Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com
## **OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE**
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
## **OMRON ARGENTINA • SALES OFFICE**
Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com
## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE**
San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. **OTHER OMRON LATIN AMERICA SALES** com +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com
## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE**
Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com
## _Authorized Distributor:_
## **Controllers & I/O**
- Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O **Robotics** • Industrial Robots • Mobile Robots
## **Operator Interfaces**
- Human Machine Interface (HMI)
## **Motion & Drives**
- Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters **Vision, Measurement & Identification**
- Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems
## **Sensing**
- Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors **Safety** • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays **Control Components** • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products **Switches & Relays** • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays **Software** • Programming & Configuration • Runtime
F1055I-E3-02 Note: Specifications are subject to change. © 2019 Omron. All Rights Reserved.
Printed in U.S.A.
_Printed on recycled paper._
Updated at February 9, 2023
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →