F39-A11
Muting Lamp, Safety Sensor, 24 VDC
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 142.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Safety sensor for Palletisers ## **F3S-TGR-SB** @ **C series** ## For Palletiser F3S-TGR-SB@C series has been developed especially for Palletisers and wrapping machine access protection applications. ## 3 Different types available We provide 3 different Types as following: - 2 beam Type (beam pitch 500 mm) - 3 beam Type (beam pitch 400 mm) - 4 beam Type (beam pitch 300 mm) ## Active - Passive system and Plug and play By using a mirror system we can achieve an active - passive multi beam system. This active passive system will improve installation time and reduce costs. ## Muting functions are integrated Following Muting functions are integrated: - Muting sensor inputs - Muting Lamp output - Override input (120 second max) - Test / Reset input - Interlock function and Test Reset input **F3S-TGR-SB** @ **C series** G-49 ## Decentralized Muting connection Box **==> picture [44 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> To Barrier<br>ia<br>To Cabinet<br>**----- End of picture text -----**<br> Furthermore, using a F39-TGR-SB-CMB1, it’s possible to reduce the wiring time and wiring material for the muting Sensors and Muting Lamp etc. In the conventional solution all wires from the light curtain, mute sensors, lamp, reset are wired back to the mute controller in the control cabinet (See Ex. 1) As you can see this solution need JUST ONE WIRE to the cabinet (See Ex. 2) **==> picture [85 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Ex. 1 Ex. 2<br>**----- End of picture text -----**<br> ## Multiple mute connections are possible ## 1. PARALLEL MUTING and TWO WAY direction ## 2. PARALLEL MUTING and ONE WAY direcion **==> picture [172 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> A2 B2 B1 A1<br>Pallet<br>CO<br>Danger Zone<br>**----- End of picture text -----**<br> **==> picture [133 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> A2 B2<br>Pallet<br>L |<br>Danger Zone<br>**----- End of picture text -----**<br> **==> picture [165 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL<br>**----- End of picture text -----**<br> ## 3. CROSS MUTING and TWO WAY direction ## 4. CROSS MUTING and ONE WAY direction **==> picture [150 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> B2 A2<br>LJ<br>Pallet<br>Danger Zone<br>**----- End of picture text -----**<br> **==> picture [167 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> B2 A2<br>Pallet<br>Danger Zone<br>|<br>Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL<br>**----- End of picture text -----**<br> Reference Muting Lamp Override and Test Switch a F3S-TGR-SB@-K@C ° Muting sensor es F3S-TGR-SB-CMB@ Mechanical Guard ***MTL** has a special software inside of F3S-TGR-SB@C which works to finalize a Muting function. ## Muting Sensors Recommendation It is recommended to use the E3Z or E3G as muting sensor. Please refer to the E3Z datasheet _Cat.No. E701-E2-Cat04-01_ and the E3G datasheet _Cat.No. E278-E2-Cat04-03_ . SOLUTION 1: Object Gaps In many palletiser applications there is a gap between objects on the pallet. The Muting function may not work correctly because Object of this gap. To avoid the mutual Gaps interruption, we recommend to Use E3G@@@@T as muting sensor. E3G-@@@@T has ON delay ~~=~~ timer internally (0 to 5 seconds) SOLUTION 2: Misalignment of pallets When using a CROSS MUTING system, It may cause that unexpected behavior when the pallets get out of alignment then E3G@@@@T also solves the problem by OFF delay timer (0 to 5 seconds). G-50 Safety Sensors / Components List of Models ## Safety Multi beam Sensors |F3S-TGR-SB2-K@C Mirror Reflection Type (Type 2)| |---| |**Shape**<br>**Number of optical**<br>**axes**<br>**Sensing Distance**<br>**Beam**<br>**Pitch**<br>**Model**<br>2<br>500<br>F3S-TGR-SB2-K2C-500(MTL)*<br>3<br>400<br>F3S-TGR-SB2-K3C-800(MTL)*<br>4<br>300<br>F3S-TGR-SB2-K4C-900(MTL)*<br>0.5 to 6 m<br>0.5 to 5 m<br>~~—~~<br>~~_~~<br>~~_—a—~~<br>~~OO~~<br>~~TS~~<br>~~a~~<br>~~—~~| |*. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL| |F3S-TGR-SB4-K@C Mirror Reflection Type (Type 4)| |**Shape**<br>**Number of optical**<br>**axes**<br>**Sensing Distance**<br>**Beam**<br>**Pitch**<br>**Model**<br>2<br>500<br>F3S-TGR-SB4-K2C-500(MTL)*<br>3<br>400<br>F3S-TGR-SB4-K3C-800(MTL)*<br>4<br>300<br>F3S-TGR-SB4-K4C-900(MTL)*<br>0.5 to 6 m<br>0.5 to 5 m<br>~~a~~<br>~~a~~<br>~~a~~<br>~~—~~| *. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL ## Muting Connecting Box (Order Separately) Flexible Connecting Box |**Appearance**<br>|**SLC Connection**<br>**Type**<br>|**Other connection**<br>|**Model**<br>|~~—~~| |---|---|---|---|---| |~~7~~|M12 8pin connector<br>without cable<br>M12 8pin connector<br>with 100 mm cable<br>~~7 ~~|4 x Muting sensor connection (4pin)<br>1 x Muting Lamp M12 (4pin)<br>1 x Override/Test input M12 (4pin)<br>1 x cabinet connection M12 (8pin)<br> ~~—~~|F39-TGR-SB-CMB1<br>F39-TGR-SB-CMB2|| |Accessories (Order Separately)||||| |Connector Cable<br>**Appearance**|**Cable length**<br>2 m<br>~~———~~|**Specification**<br>**Model**<br>M12 connector (8pin Socket)<br>F39-TGR-SB4-CVLB2R<br>~~ee~~||| ||5 m|For cabinet connection<br>(From F3S-TGR-SB@-K@C or F3S-TGR-|F39-TGR-SB4-CVLB5R|| |~~| ~~|10 m<br>2 m<br> ~~i~~|SB-CMB@)<br>M12 connector (4pin Plug)<br>For Muting sensor, Muting Lamp connec-<br>tion and Override/Test connection|F39-TGR-SB4-CVLB10R<br>F39-TGR-SB4-CVLB2MC<br>~~a~~|| Accessories (Order Separately) Connector Cable **F3S-TGR-SB** @ **C series** G-51 ## Connector Plug Assemblies, Screw-on Type |**Appearance**|**Cable connection**<br>**direction**|**Specification**|**Connection**<br>**method**|**Applicable cable**<br>**diameter**|**Model**| |---|---|---|---|---|---| |~~a~~|Straight<br>~~a~~|DC only 4pin Plug|Screw-on|3 dia. (3 to 4 dia.)|XS2G-D4S5| |~~a~~|Right angle<br>~~a~~||||XS2G-D4S6| Muting Lamp **Appearance Specification Model** ~~es ee~~ 24 V DC F39-A11 Bulb for Maintenance **Appearance Specification Model** ~~es ee~~ 24 V DC 3 W E14 F39-A11MB Laser alignment Kit |**Appearance**||**Model**| |---|---|---| ||F39-LKK2-SB|| G-52 Safety Sensors / Components Rating and Performance ## Safety sensors ## F3S-TGR-SB@-K@C |**Item**|**Model**|**Model**| |---|---|---| ||**F3S-TGR-SB4-K**@**C-**@@@**(MTL)***|**F3S-TGR-SB2-K**@**C-**@@@**(MTL)***| |Sensor type|Type 4|Type 2| |Applicable safetycategory|4, 3, 2, 1, B|2, 1, B| |Operating range|F3S-TGR-SB@-K2C<br>0.5 - 6 m<br>F3S-TGR-SB@-K3C/K4C<br>0.5 - 6 m|| |Beam pitch and Number of beam|F3S-TGR-SB@-K2C<br>500 mm<br>2 beam with mirror<br>F3S-TGR-SB@-K3C<br>400 mm<br>3 beam with mirror<br>F3S-TGR-SB@-K4C<br>300 mm<br>4 beam with mirror|| |Outermost beam gap|F3S-TGR-SB@-K2C<br>500 mm<br>F3S-TGR-SB@-K3C<br>800 mm<br>F3S-TGR-SB@-K4C<br>900 mm|| |Effective aperture angle(EAA)|Within ±2.5°|Within ±5°| |Light source|Infrared LED(880 nm)|| |Power supply|24 VDC ± 20%|| |Current Consumption|420 mA|| |OSSD|Two PNP transistor outputs, 250 mA each.(500 mA sum)|| |Output operation mode|Light - ON|| |Test functions|Self-test(afterpower ON and duringoperation, one cycle duringresponse time)|| |Protection|Output short-circuitprotection, Reverse Polarity protection|| |Response time|ON to OFF 16ms max<br>OFF to ON 300 ms(Maximum Power-ON time is 900 ms)|| |Ambient temperature|Operating: -10 to +55 °C(with no dew condensation)|| |Ambient humidity|15% to 95%(non condensing)|| |Metal housing (Al) painted|Yellow(RAL 1303 F14)|| |Degree ofprotection|IP65|| |Accessories|M6 T-Bolt x 8, M6 Nut x 8<br>Mountingfixture x 4|| |Applicable standards|EN61496-1; 1997<br>prEN61496-2; 1997|| *. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL ## Muting Connecting Box ## F3S-TGR-SB-CMB@ |**Item**<br>**Model**|**Item**<br>**Model**|**F39-TGR-SB-CMB**@| |---|---|---| |Power supply||24 VDC ± 20%| |Consumption||10 W max| |Ambient temperature||Duringoperation: -10 to +55 °C(with no dex condensation)| |Ambient humidity||15% to 95%(non condensing)| |RX connector||M12 8pins female| |Cabinet connector||M12 8pins male| |Sensor connector||4 x M12 4pins female| |Mutingindicator||M12 4pins female| |Test / Override connectors||M12 4pins female| |Metal housing (Al) painted||Yellow(RAL 1303 F14)| |Degree ofprotection||IP65| |Material|Case|Aluminium| ||Connector|Brass with nickelplate| ||Front Cover|Aluminium| |Weight||0.5 kg| |Accessories||M6 T-Bolt x 4, M6 Nut x 4<br>Mountingfixture x 2, Connector cover x 2| **F3S-TGR-SB** @ **C series** G-53 **Item Model F39-TGR-SB-CMB** @ Applicable standards 93/68/EEC DIN V VDE 0801:1990 and am.A1:1994 EN 50081-2:1993 EN 55022:1998 Dimensions F3S-TGR-SB-K@C-@@@ with Mounting Brackets@C-@@@ with Mounting BracketsC-@@@ with Mounting Brackets@@@ with Mounting Brackets with Mounting Brackets 47.5 37.7 35 rT ~~|~~ | **Model A C E** F3S-TGR-SB@-K2C500 614 mm 500 mm 500 mm F3S-TGR-SB@-K3C800 914 mm 800 mm 400 mm F3S-TGR-SB@-K4C900 1,014 mm 900 mm 300 mm ## Dimensions ## F3S-TGR-SB-K@C-@@@ with Mounting Brackets@C-@@@ with Mounting BracketsC-@@@ with Mounting Brackets@@@ with Mounting Brackets with Mounting Brackets G-54 Safety Sensors / Components ## F39-TGR-SB-CMB1 Muting connection box Mounting bracket (Common bracket for F3S-TGR-SB@-K@C and F39-TGR-SB-CMB@ ## Connector Plug Assemblies, Screw-on Type XS2G-D4S5 XS2G-D4S6 **==> picture [160 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> M12 x 1 58.7<br>20 dia. 14.9 dia. 14 dia.<br>| = o e<br>M12 x 1<br>39.7<br>20 dia. 14.9 dia.<br>a<br>== 39.6<br>Te<br>a a<br>14 dia.<br>**----- End of picture text -----**<br> **F3S-TGR-SB** @ **C series** G-55 Connection ## F3S-TGR-SB@-K@C Connection example **==> picture [434 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> When using Muting function<br>Passive side Active side<br>S1<br>+24Vdc<br>0Vdc<br>S1<br>S1: External Test / Interlock reset Switch<br>+24Vdc<br>MIA : Muting input A<br>MIB : Muting input B<br>0Vdc ML : Muting Lamp<br>White Brown Green Yellow Pink Gray Blue Red Shield<br>MIA MIB<br>ML<br>White Brown Green Yellow Pink Gray Blue Red Shield OSSD1 OSSD2<br>OSSD1 OSSD2<br>**----- End of picture text -----**<br> In case of Cat 4 (EN954-1), OSSD1/2 must be connected Safety Relay Unit (G9SA, G9SB-301B etc.) with feedback monitor ## Pin reference |Front View|Pin No.|Signal Name|Wire Color| |---|---|---|---| |1<br>7<br>2<br>8<br>4<br>5<br>6<br>3|1|Test and Reset Input|White| ||2|+24 Vdc|Brown| ||3|Muting A Input|Green| ||4|Muting B Input|Yellow| ||5|OSSD1 (OUT1)|Gray| ||6|OSSD2 (OUT2)|Pink| ||7|0 Vdc|Blue| ||8|Muting Lamp (0 Vdc)|Red| G-56 Safety Sensors / Components ## F3S-TGR-SB-CMB@ Pin and Plug reference 1) To F3S-TGR-SB Series Front View Pin No. Signal Name Wire Color 1) To Barrier (F3S-TGR-SB series) 1 Test and Reset Input White M12 8pin connector (Female)[*1] 2 +24 Vdc Brown 3 Muting A Input Green 2) Muting Sensor B2 1 2 4 Muting B Input Yellow M12 5pin connector (Female) 3 8 7 5 OSSD1 (OUT1) Gray 4 6 5 3) Muting Sensor A2 6 OSSD2 (OUT2) Pink M12 5pin connector (Female) 7 0 Vdc Blue 8 Muting Lamp (0 Vdc) Red 4) Muting Sensor B1 M12 5pin connector (Female) 2), 3) 4), 5) Wiring of Muting Sensor connection Front View Pin No. Signal Name Wire Color 5) Muting Sensor A1 M12 5pin connector (Female) 1 +24 Vdc Brown 1 2 2 No connect White 6) Muting Lamp 5 M12 5pin connector (Female) 4 3 3 0 V Blue 4 PNP Input Black ~~n=~~ 7) Test/Override 6) Wiring of Muting Lamp connection M12 5pin connector (Female) Front View Pin No. Signal Name Wire Color 1 +24 Vdc Brown 8) From Cabinet 1 2 2 No connect White M12 8pin connector (Male) 4 5 3 3 No connect Blue 4 0 V Black *1 In case of F3S-TGR-SB-CMB2, M12 8pin connector with 100 mm cable 7) Test/Override connection Front View Pin No. Signal Name Wire Color 1 +24 Vdc Brown 1 2 2 Test input White 5 4 3 3 No connect Blue 4 Override input Black ~~oo~~ 8) From Cabinet Front View Pin No. Signal Name Wire Color 1 Test and Reset Input White 2 +24 Vdc Brown 3 Muting A Input Green 2 1 4 Muting B Input Yellow 8 3 7 4 5 OSSD1 (OUT1) Gray 6 5 6 OSSD2 (OUT2) Pink 7 0 Vdc Blue 8 Muting Lamp (0 Vdc) Red **F3S-TGR-SB** @ **C series** G-57 ~~=~~ Application ## Manual Reset Mode (by Safety barrier) ## F3S-TGR-SB4-K2C / F39-TGR-SB-CMB@ / G9SB-200-B or 301-B **==> picture [447 x 674] intentionally omitted <==** **----- Start of picture text -----**<br> Passive side F3S-TGR-SB@-K@C Active side<br>DIP switch Status of F3S-TGR-SB@-K@C<br>Muting sensor B2<br>Muting sensor A2<br>Muting sensor B1<br>Manual Reset Mode:<br>Every DIP SW has to be OFF status<br>Muting sensor A1 Factory setting:<br>Auto Reset Mode (Sw No 4 is ON)<br>Muting Lamp<br>Override Switch<br>F39-TGR-SB-CMB@<br>re<br>Test / Reset Switch<br>+24VDC<br>KM1 b<br>KM2 b<br>0VDC<br>L ali Liss a<br>e<br>et Ball|<br>OOD<br>G9SB-301-B<br>KM1 1<br>KM2<br>1<br>F39-TGR-SB-CMB@ Plug reference<br>Muting Sensor (B2/A2/B1/A1) Muting Lamp Test and Override inputs<br>Black Black(0Vdc) Black(Override (N.O))<br>PNP OUT<br>4 3 Blue 0Vdc 4 3 4 3<br>5 Brown 5 5<br>1 2 +24Vdc 1 2 1 2<br>Muting Lamp White(Test/Reset (N.C))<br>Muting Sensor Brown(+24Vdc)<br>Brown(Common)<br>ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.<br>To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.<br>Cat. No. E19E-EN-01 In the interest of product improvement, specifications are subject to change without notice.<br>1 ON 1 ON<br>2 2<br>3 3<br>4 4<br>BROWN (+24VDC)<br>BLUE (0VDC) SHIELD GRAY (OSSD 1) PINK (OSSD 2)<br>**----- End of picture text -----**<br> G-58 Safety Sensors / Components
Updated at June 9, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →