F03-01 SUS304 ELECTRODE
Electrode, 1 m, M6
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Controller Accessories
- Current Rating:-; Product Range:-; Accessory Type:Electrode; External Length / Height:1m; For Use With:Purified Water Applications; Length:1m
- Product Range: -
- Current Rating: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 18.66 € |
| Current stock | 50+ |
| Lead time | 30 days |
**Electrodes and Accessories F03-** @ ## **A Wide Variety of Electrodes for Long Lasting Reliability** - Standard Electrodes are made of stainless steel (SUS 304) and can be used in applications for purified water. - SUS316 Electrodes can be used in applications where resistance to corrosion is required. Titanium and Hastelloy Electrodes can be used in applications where resistance to acid is required. - For applications where long electrodes are required, a connection nut and two Lock Nuts can be used to extend the electrodes 1 m at a time. - **Refer to** _**Safety Precautions for Electrodes and Electrode Holders.**_ ## **Orderin Information g** Material indications are provided on all OMRON electrodes, connection nuts, and Lock Nuts. ## **Electrodes** Select an electrode appropriate for the type of liquid. Refer to _Technical Guide for Level Controllers_ . |**Model**<br>~~a~~<br>~~ee~~<br>~~ee~~|**Material**<br>~~ee~~|**Weight (g)**<br>~~|~~<br>~~ee~~|**Material indication lines**<br>~~|~~<br>~~ee~~|**Material indication lines**<br>~~|~~<br>~~ee~~| |---|---|---|---|---| |F03-01 SUS304<br>~~ee~~<br>~~ee~~|SUS304<br>~~ee~~|Approx. 170<br>~~|~~<br>~~ee~~<br>~~rr~~|1 line<br>~~|~~<br>~~ee~~|Electrodes<br>M6<br>Material<br>indication<br>lines| |F03-01 SUS316<br>~~ee~~<br>~~ee~~|SUS316<br>~~ee~~<br>~~rr~~||2 lines<br>~~|~~<br>~~ee~~|| |F03-01 HAS B<br>~~ee~~<br>~~rs~~|N10665 (See note.)<br>~~ee~~<br>~~rs~~<br>~~rr~~|Approx. 195<br>~~ee~~<br>~~rs~~<br>~~rr~~|3 lines<br>~~ee~~<br>~~rs~~|| |F03-01 HAS C<br>~~rs~~<br>~~es~~<br>~~Ps~~|N10276 (See note.)<br>~~rs~~<br>~~rr~~<br>~~es~~<br>~~es~~|Approx. 190<br>~~rs~~<br>~~rr~~<br>~~es~~|4 lines<br>~~rs~~<br>~~es~~|| |F03-01 TITANIUM<br>~~es~~<br>~~Ps~~|Titanium<br>~~es~~<br>~~es~~|Approx. 100<br>~~es~~|5 lines<br>~~es~~|| **Note:** UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number for each material. ## **Insulated Electrodes** Electrodes are insulated with a plastic sheath to prevent them from touching each other and to isolate them from debris in the liquid. Before application, strip back about 10 cm of the sheath at the end to ensure sufficient conductivity. |F03-01 SUS304<br>F03-01 SUS304<br>F03-01 SUS316|F03-01 SUS304<br>F03-01 SUS304<br>F03-01 SUS316|**Model**<br>Vinyl Tubing<br>Fluororesin Tubing<br>Vinyl Tubing| |---|---|---| |F03-01 SUS316|F03-01 SUS316|Fluororesin Tubing| **Note:** Tubing comes in 1-m lengths with a sheath thickness of 0.5 mm. ## **Connecting Nuts** |**Model**|**Material**|**Weight (g)**|**Material**<br>**indication**| |---|---|---|---| |F03-02 SUS304|SUS303<br>(Equivalent to SUS304)|Approx. 12|Blank| |F03-02 SUS316|SUS316||6| |F03-02 HAS B|N10665 (See note.)|Approx. 20|B| |F03-02 HAS C|N10276 (See note.)||C| |F03-02 TITANIUM|Titanium|Approx. 6|T| - **Note:** UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number for each material. **1** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ **F03-** @ ## **Electrode Sets** An Electrode Set consists of an electrode, a connecting nut, and two Lock Nuts. |Lock Nuts.|||| |---|---|---|---| |**Set model**|**Components**|**No. of parts**<br>**in an set**|**Weight**<br>**(g)**| |F03-60 SUS304|F03-01 SUS304|1|Approx.<br>190| ||F03-02 SUS304|1|| ||F03-03 SUS304|2|| |F03-60 SUS316|F03-01 SUS316|1|| ||F03-02 SUS316|1|| ||F03-03 SUS316|2|| **Note:** Hastelloy and titanium Electrodes do not come in sets. ## **Lock Nuts** |**Lock Nuts**|||| |---|---|---|---| |**Model**|**Material**|**Weigh**<br>**(g)**|**t**<br>**Material**<br>**indication**| |F03-03 SUS304<br>(See note 1.)|SUS303<br>(Equivalent to SUS304)|Approx<br>2|.<br>Blank<br>6| |F03-03 SUS316<br>(See note 1.)|SUS316||| |F03-03 HAS B|N10665<br>(See note 2.)|Approx<br>5|.<br>B<br>C| |F03-03 HAS C|N10276<br>(See note 2.)||| |F03-03 TITANIUM|Titanium|Approx<br>2|.<br>T| - **Note: 1.** SUS304 and SUS316 Lock Nuts come with spring washers made of the same material. **2.** UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number for each material. ## **Electrode Separators** When long electrodes are required, use Separators at each joint (every 1 m) to prevent the Electrodes from touching each other. Use a 1-pole Separator with BF Electrode Holders. The five-pole model can be used with PS-5S and PS-4S Electrode Holders. Separators cannot be used with PS-31 Electrode Holders. |**Model**|**No. of**<br>**Electrodes**|**Dimensions**|**Dimensions**|**Applicable**<br>**Electrode**<br>**Holder**|**Weight (g)**|**Material**|**Operating**<br>**Temperature**|Electrode<br>Holder<br>Separator<br>Separator<br>Lock Nut<br>Electrode<br>Spring<br>washer<br>Connecting<br>nut| |---|---|---|---|---|---|---|---|---| |F03-14 1P|1||6.5 dia.<br>28 dia.|BF-@(R)|Approx. 15|Ceramic|250°C max.|| |F03-14 3P|3|Thr|ee, 7-dia. holes<br>41<br>20|PS-3S(R)|Approx. 30|||| |F03-14 5P|5|20|Five, 7-dia.<br>holes<br>~~46~~|PS-4S(R)<br>PS-5S(R)||||| ## **Accessories (Order Separately)** |**Application**|**Model**| |---|---| |Protective Cover (for PS-@S and BF-3/-5)|F03-11| |MountingFrame (for PS-@S)|F03-12| |MountingFrame for Installingin Concrete (for PS-@S)|F03-13| |Dust-proof Rubber Cap (for PS-31)|F03-31| **2** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ **F03-** @ ## **Dimensions of Electrodes and Accessories** **Note:** All units are in millimeters unless otherwise indicated. **==> picture [510 x 201] intentionally omitted <==** **----- Start of picture text -----**<br> Electrode Lock Nut<br>M6<br>F03-01 F03-03 M6 F03-03<br>M6 5.23 dia. SUS304 HAS B<br>SUS316 HAS C<br>Titanium<br>10 5 10 5.5<br>Connecting nut<br>F03-02 F03-02 F03-02<br>SUS304 HAS B M6 Titanium<br>10 20<br>SUS316 20 HAS C<br>M6<br>10 20<br>11.5 (See note 2.) M6 (See note 2.)<br>Threaded section: 21Standard: 1 m±2<br>13<br>11.5<br>)<br>13<br>10 See note 1.()(15 11.5<br>**----- End of picture text -----**<br> **Note: 1.** Dimension when mounting Electrodes. **2.** Clamp screws are not provided for Hastelloy B, Hastelloy C, or titanium models. F03-03 Lock Nuts are used to mount Electrodes. ## ■ **Safety Precautions** Refer to _Safety Precautions for All Level Controllers_ . ## ■ **Precautions for Correct Use** ## **Cleaning Electrodes** Electrodes are clean when they are dispatched. In the rare occasion that they become dirty during transit or storage, such as forming an oil film on the surface, clean them again before using them. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. **3** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ ## **Safet Precautions for Electrodes and Electrode Holders y** ## ! **WARNING** **==> picture [35 x 66] intentionally omitted <==** Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Do not attempt to disassemble, repair, or modify the Controller while power is being supplied. Doing so may occasionally result in electric shock. ## **Precautions for Safe Use** Do not use the Controller in locations subject to explosive or combustible dust, combustible gas, flammable vapors, corrosive gas, excessive dust, salt-water spray, or water drops. ## ■ **Electrode Precautions** ## **Precautions for Correct Use** - Always disconnect the 61F when a tester to perform insulation resistance tests on the Electrode circuit. - If the Electrodes are to be cut, bevel the cut surface. **==> picture [243 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> ● Be careful of the distances between<br>Electrodes.<br>Allow a sufficient distance (normally 1 m)<br>between Electrodes if they are used in<br>seawater or sewage. Use a low-sensitivity<br>61F-@D(-@ND) Level Controller if sufficient<br>distance cannot be obtained. 1 m 1 m<br>● Make the common (ground)<br>Electrode longer.<br>For a group of three Electrodes consisting of E1<br>a short, a medium, and a long Electrode,<br>medium Electrode to Econnect the shortest Electrode to E2, and the long 1, the E2 50 mmmin.<br>Electrode to E3. The long Electrode (E3) must E3<br>be at least 50 mm longer than the other<br>Electrodes.<br>**----- End of picture text -----**<br> - **Electrodes must be cleaned.** **==> picture [243 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Electrodes must be cleaned.<br>• At about six months after installation,<br>remove the Electrodes and use fine Air hole dia.:<br>sandpaper to remove film from the Approx. 10<br>surface. After that, clean the<br>Pipe with<br>Electrodes once or twice a year. If the diameter of<br>Electrodes are used in liquid with a approx. 4” min.<br>lot of dirt or scum, insulating film may<br>form, particularly on the surfaces of Amount of Waste<br>the Electrodes, and result in Material<br>Accumulating<br>operating failures. Remove the between Periodic<br>insulating film once every three Cleanings<br>months or so. For sewage tanks, Sewage tank<br>sewage, oil film, or other applications and tank surface<br>with a lot of waste material, use a<br>pipe such as the one shown at the<br>right.<br>**----- End of picture text -----**<br> - Use a pipe with a diameter of at least four inches. - Install the pipe with a diagonal cut at the end as shown in the figure at the right according to the estimated waste material accumulation. - Provide an air ventilation hole with a diameter of approx. 10 mm on the upper part of the pipe. - Breakwater Pipe Mounting Precautions **==> picture [237 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> Install a breakwater pipe as shown in<br>the figure at the right for applications Air hole dia.:<br>with large waves or fast flow, such as Approx. 10<br>for water purification.<br>Make at least<br>• Use a pipe with a diameter of at four opposing<br>least four inches. holes with a<br>diameter of 6 to<br>• To improve the circulation of 10 mm near the<br>liquid inside the pipe, make at end of each<br>least four opposing holes with a Electrode.<br>diameter of 6 to 10 mm near the Pipe with a<br>end of each electrode. diameter of at<br>least four inches.<br>• Provide an air ventilation hole<br>with a diameter of approx. 10 mm<br>on the upper part of the pipe.<br>**----- End of picture text -----**<br> - The procedures above also apply to using Electrode bands. ## ● **Be careful of the operating level.** Changes in the type of liquid or the power Electrode supply voltage may cause the operating position Holder to fluctuate somewhat even when the tip of the Electrode reaches the level of the liquid. Separator ## ● **Use separators.** When the required length of the Electrode is 1 m or more, use a Separator at each joint between two Electrodes to prevent the Electrodes from coming into contact each other in the water. ## ● **Be careful of suspended matter causing Electrodes to come into contact with each other.** Use Tubing Electrodes if factors such as suspended matter cause Electrodes to come into contact with each other. To ensure conductivity, strip off at least 100 mm from the end of the Tubing and do not use Tubing on the common (earth) Electrode. ## ● **Mount Electrodes vertically.** Water scum can easily accumulate on insulated parts and may cause insulation failure. Mount the Electrodes vertically. **4** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ ## ■ **Electrode Holder Precautions** ## **Precautions for Correct Use** - Never mount the Electrode Holder horizontally. Mounting the Electrode Holder horizontally may cause liquid to leak from the Electrode Holder and result in 61F reset failure. - The resin may become discolored after long-term use or storage. This is normal and does not present any problems in using the product. - When wiring the BF, use M6 crimp terminals. - Do not pull on the cable. - Disconnect the wiring with the Level Controller before inspecting Electrode Holders. - Use OMRON 61F Floatless Switches for control devices. - Consult with your OMRON representative before using the BF in any liquid other than water. ## **Precautions for Tightening Torque and Work** |**BS-1**<br>**(See**<br>**note 1.)**|Wire installation section(M4) (See note 3.)|137.2 N·cm| |---|---|---| ||Electrode Holder installation section (M18)<br>(See note 2.)|6500.0 N·cm| |**BS-1T**<br>**(See**<br>**note 1.)**|Wire installation section(M4) (See note 3.)|137.2 N·cm| ||Electrode Holder installation section (M18)<br>(See note 2.)|196.1 N·cm| - **Note: 1.** A gasket is supplied with the BS-1. A gasket is not required to mount the BS-1T. (One is not supplied.) **2.** Wind commercially available sealing tape two or three times around the M18 screw section before tightening the screws. **3.** When installing the wiring, secure nut 2 with a wrench so that no force is applied to the terminal bolt, and complete the tightening with nut 1 (as in the following figure). If nut 2 is not secured, the load on the terminal bolt may cause leakage of steam and pressure. **==> picture [159 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal bolt<br>1<br>Wire<br>Crimp terminal<br>2<br>**----- End of picture text -----**<br> - Always use an F03-11 Protective Cover if the BF-3 (-5) is used outdoors or in locations subject to water, dust, dirt, or other foreign matter. Foreign matter adhering to the electrode insulators may cause incorrect operation due to leaking. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. **5** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ **Safet Precautions for All Level Controllers y** Refer to the _Safety Precautions_ section for each product for specific precautions applicable to that product. ## ! **WARNING** Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Do not attempt to disassemble, repair, or modify the product while power is being supplied. Doing so may occasionally result in electric shock. ## ■ **Precautions for Safe Use** In order to ensure safe operation, be sure to observe the following points. **1.** Use a power supply voltage within the specified range. **2.** Do not use the Controller in locations subject to flammable gases or objects. **3.** Insert the Socket until it securely clicks into place. **4.** Do not short the load connected to the output terminals. **5.** Do not connect the power supply in reverse. **6.** Do not use the Controller in locations subject to explosive or combustible dust, combustible gas, flammable vapors, corrosive gas, excessive dust, salt water spray, or water drops. **7.** Use the Level Controller within the specified ranges for ambient operating temperature, ambient operating humidity, and storage temperature (including during transportation). **8.** Do not store, transport, or use the product in locations subject to high humidity or condensation, outdoors, or in direct sunlight. **9.** Do not store, transport, or use the product in locations subject to excessive shock or vibration. **10.** Recheck all wiring before using the product. **11.** Read and understand the entire catalog before attempting to use or maintain the product. **12.** Do not attempt to disassemble the product during use. **13.** Do not use thinner or similar solvent for cleaning. Use commercial alcohol. **14.** When discarding, properly dispose of the product as industrial waste. **15.** Be careful not to get injured when taking apart the product for disposal. ## ■ **Precautions for Correct Use** **For details, refer to** _**Technical Guide for Level Controller**_ **s.** In the interest of product improvement, specifications are subject to change without notice. **C-1** (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ ## **Read and Understand This Catalog** Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## **Warranty and Limitations of Liability** ## **WARRANTY** OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ## **LIMITATIONS OF LIABILITY** OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. ## **Application Considerations** ## **SUITABILITY FOR USE** OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certifi cation documents identifying ratings and limitations of use that apply to the products. This information by itself is not suffi cient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: - Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. - Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. - Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## **Disclaimers** ## **CHANGE IN SPECIFICATIONS** Product specifi cations and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when signifi cant construction changes are made. However, some specifi cations of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fi x or establish key specifi cations for your application on your request. Please consult with your OMRON representative at any time to confi rm actual specifi cations of purchased product. ## **DIMENSIONS AND WEIGHTS** Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ## **ERRORS AND OMISSIONS** The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. ## **PERFORMANCE DATA** Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ## **PROGRAMMABLE PRODUCTS** OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. ## **COPYRIGHT AND COPY PERMISSION** This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. In the interest of product improvement, specifications are subject to change without notice. 2007.9 OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.
Updated at April 22, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →