Image not available
Illustrative purposes only
F02B250V1/4AS
CARTRIDGE FUSES
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: Cartridge Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 21 |
| Price | 11.13 € |
| Current stock | 25+ |
| Lead time | 30 days |
INCH-POUND MIL-PRF-15160/2H 15 October 2008 SUPERSEDING MIL-PRF-15160/2G 7 July 2006 ## PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F02 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. |Inches|mm| |---|---| |0.004|0.10| |0.010|0.25| |0.031|0.79| |0.230|5.84| |0.250|6.35| |1.250|31.75| NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 1. Style F02, fuse. AMSC N/A FSC 5920 ## MIL-PRF-15160/2H REQUIREMENTS: Interface and physical dimensions: See figure 1. Terminals: Ferrule type. Material: Brass, copper, phosphor bronze, or copper alloy. Finish: Nickel, or silver plated when specified. Strength: Method 211 of MIL-STD-202, test condition E, 10 inch-ounce torque between ferrules and fuse body. Body: Glass tube. Electrical: Current rating: See table I. Voltage rating: See table I. Characteristic: See table I. Overload interrupt: See table I (at all temperatures between minus 55°C and plus 85°C). Short circuit interrupt: See table I. |Shock:|F02A|1/100A through 3/4A|MIL-STD-202, method 213, test condition I| |---|---|---|---| ||F02A|1A through 30A|MIL-STD-202, method 207, (HI shock)| ||F02B|1/100A through 8/10A|MIL-STD-202, method 213, test condition I| ||F02B|1A through 30A|MIL-STD-202, method 207, (HI shock)| |Vibration:|F02A|1/100A through 30A|MIL-STD-202, method 204, test condition A (except 5g| ||||peak)| ||F02B|1/100A through 8/10A|MIL-STD-202, method 201| ||F02B|1A through 30A|MIL-STD-202, method 204, test condition A| ||||(except 5g peak)| Type designation: Type designation shall be as specified in table I. 2 TABLE I Type designations and electrical rating. ||Type designation|Type designation|Type designation|Overload interrupt time2<br>/|Overload interrupt time2<br>/|AC short circuit interrupt.|AC short circuit interrupt.|AC short circuit interrupt.| |---|---|---|---|---|---|---|---|---| |Style|Characteristic|Maximum<br>voltage|Current<br>rating3<br>/<br>(amperes)|135% of rating– Max. 1 hour||||| |||||200% of rating<br>(seconds)|300% of rating<br>(seconds)|32 volts|125 volts|250 volts| |F02<br>F02<br>F02<br>F02<br>F021<br>/<br>F021<br>/<br>F021<br>/<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F02<br>F021<br>/<br>F02<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F02<br>F02<br>F02<br>F021<br>/<br>F02<br>F02|A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A<br>A|250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>125V<br>125V<br>32V|1/100A<br>1/32A<br>1/16A<br>1/8A<br>15/100A<br>175/100A<br>3/16A<br>2/10A<br>1/4A<br>3/10A<br>3/8A<br>1/2A<br>6/10A<br>3/4A<br>1A<br>1 1/4A<br>1 1/2A<br>1 6/10A<br>2A<br>2 1/2A<br>3A<br>4A<br>5A<br>6A<br>8A<br>10A<br>15A|0.0003 – 1.0<br>0.0008 – 1.0<br>0.009 – 2.0<br>0.010 – 2.0<br>0.010 – 2.0<br>0.010 – 2.0<br>0.010 – 2.0<br>0.010 – 2.0<br>0.020 – 2.0<br>0.030 – 2.5<br>0.030 – 2.5<br>0.030 – 3.0<br>0.030 – 3.0<br>0.030 – 3.0<br>0.050 – 3.0<br>0.050 – 3.0<br>0.050 – 3.0<br>0.050 – 3.0<br>0.080 – 3.0<br>0.15 – 3.0<br>0.15 – 5.0<br>0.15 – 5.0<br>0.15 – 5.0<br>0.15 – 5.0<br>0.20 – 10.0<br>0.20 – 10.0<br>0.30 – 10.0|0.0001 – 0.003<br>0.0002 – 0.003<br>0.001 – 0.030<br>0.003 – 0.15<br>0.008 – 0.15<br>0.008 – 0.15<br>0.008 – 0.15<br>0.008 – 0.15<br>0.008 – 0.20<br>0.008 – 0.20<br>0.008 – 0.30<br>0.015 – 0.40<br>0.015 – 0.40<br>0.015 – 0.40<br>0.015 – 0.40<br>0.02 – 0.40<br>0.02 – 0.40<br>0.02 – 0.40<br>0.04 – 0.40<br>0.04 – 0.70<br>0.04 – 1.0<br>0.04 – 1.0<br>0.04 – 1.0<br>0.04 – 1.0<br>0.10 – 2.0<br>0.10 – 2.0<br>0.10 – 2.0|10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A|10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>Not rated|35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>100A<br>100A<br>Not rated<br>Not rated<br>Not rated| See footnotes at end of table. TABLE I Type designations and electrical rating - Continued. ||Type designation|Type designation||Overload interrupt time 2/|Overload interrupt time 2/|AC short circuit interrupt.|AC short circuit interrupt.|AC short circuit interrupt.| |---|---|---|---|---|---|---|---|---| |Style|Characteristic|Maximum<br>voltage|Current<br>rating3<br>/<br>(amperes)|135% of rating– Max. 1 hour||||| |||||200% of rating<br>(seconds)|300% of rating<br>(seconds)|32 volts|125 volts|250 volts| |F02<br>F021<br>/<br>F021<br>/<br>F02<br>F02<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F021<br>/<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F02<br>F02<br>F02|A<br>A<br>A<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B|32V<br>32V<br>32V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V<br>250V|20A<br>25A<br>30A<br>1/100A<br>1/32A<br>1/16A<br>1/10A<br>1/8A<br>15/100A<br>3/16A<br>2/10A<br>1/4A<br>3/10A<br>3/8A<br>4/10A<br>1 2A<br>6/10A<br>7/10A<br>3/4A<br>8/10A<br>1A<br>1 1/4A<br>1 1/2A<br>1 6/10A<br>2A<br>2 1/2A<br>2 8/10A|0.40 – 10.0<br>0.50 – 10.0<br>0.50 – 10.0<br>4.0 – 120.0<br>4.0 – 120.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0– 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 60.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0–90.0|0.15 – 2.0<br>0.15 – 2.0<br>0.15 – 2.0<br>3.0 – 40.0<br>3.0 – 40.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 20.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5–30.0|10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A|Not rated<br>Not rated<br>Not rated<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A|Not rated<br>Not rated<br>Not rated<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A<br>35A| See footnotes at end of table. TABLE I Type designations and electrical rating – Continued. ||Type designation|Type designation|Type designation|Overload interrupt time2<br>/|Overload interrupt time2<br>/|AC short circuit interrupt.|AC short circuit interrupt.|AC short circuit interrupt.| |---|---|---|---|---|---|---|---|---| |Style|Characteristic|Maximum<br>voltage|Current<br>rating3<br>/<br>(amperes)|135% of rating– Max. 1 hour||||| |||||200% of rating<br>(seconds)|300% of rating<br>(seconds)|32 volts|125 volts|250 volts| |F02<br>F02<br>F021<br>/<br>F02<br>F021<br>/<br>F021<br>/<br>F02<br>F02<br>F021<br>/<br>F02<br>F02<br>F021<br>/<br>F021<br>/|B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B<br>B|250V<br>250V<br>125V<br>125V<br>125V<br>125V<br>32V<br>32V<br>32V<br>32V<br>32V<br>32V<br>32V|3A<br>3 2/10A<br>4A<br>5A<br>6 1/4A<br>7A<br>8A<br>10A<br>12A<br>15A<br>20A<br>25A<br>30A|4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 90.0<br>4.0 – 700.0<br>4.0 – 700.0<br>4.0 – 700.0<br>4.0 – 700.0<br>4.0 – 700.0<br>4.0 – 700.0<br>4.0 – 700.0|1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.5 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0<br>1.0 – 30.0|10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A|10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>10,000A<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated|35A<br>35A<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated<br>Not rated| ## 1/ INACTIVE FOR NEW DESIGN AFTER 30 JANUARY 1970. - 2/ The overload interrupt time ranges, as shown, cover the temperature range from minus 55°C to plus 85°C. For characteristic B, the overload interrupt time at room ambient temperature shall be not less than 12 seconds at 200 percent rating. - 3/ For silver plated terminals the designator “S” is added after the current rating. MIL-PRF-15160/2H ## VERIFICATION: Qualification inspection is not applicable for the 1/100A thru 3/8A characteristic A fuses, the 1/100A thru 1/8A and 20A thru 30A characteristic B fuses of this specification sheet (see table l) and shall be replaced by acceptance testing consisting of Group A and Group B inspections per MIL-PRF-15160, prior to delivery. ## INSPECTION ROUTINE: Overload tests (group II): Fuses for the overload interrupt test shall be selected and tested as specified in table II for qualification test. TABLE II. Overload tests. |Examination of test|Number of sample<br>fuses| |---|---| |Group II<br>Terminal strength<br>Overload interrupt1<br>/<br>135% at room ambient<br>200% at –55°C<br>200% at +85°C<br>300% at –55°C<br>300% at +85°C|20<br>12<br>4<br>4<br>4<br>4<br>4| - 1/ For characteristic B fuses, only, four additional fuses shall be tested at 200 percent of rating at - room ambient temperature. Low voltage overload interrupt (group V for qualification; group III for group C inspection): Four sample characteristic B fuses of each current rating shown in table III shall be subjected to 135 percent current at the voltage specified in the table. The fuses shall interrupt the circuit within 1 hour. The test shall be conducted at room ambient. TABLE III. Low voltage overload interrupt. (Characteristic B fuses only). |Ampererating|Testvoltage| |---|---| |1/100A<br>1/4A<br>1/2A<br>7/10A<br>8/10A<br>1A|36V<br>15V<br>10V<br>8V<br>6V<br>5V| Note – for low voltage applications, see 6.1.5.1 for caution regarding low voltage applications. Short circuit test: The number of group III samples for qualification and qualification retention (group C) testing shall consist of 4 sample fuses of each of the types and of the current ratings as shown in table IV. Short circuit interrupt tests shall be conducted at the ac voltage indicated, and the fuses shall withstand a minimum short circuit current as shown in table IV. 6 ## MIL-PRF-15160/2H TABLE IV. Short circuit tests. |Fuse type|Current rating|Short circuit<br>current|AC test<br>voltage| |---|---|---|---| |F02A<br>F02A<br>F02A<br>F02A<br>F02B<br>F02B<br>F02B|4A<br>6A<br>10A<br>30A<br>3 2/10A<br>7A<br>30A|35A<br>100A<br>10,000A<br>10,000A<br>35A<br>10,000A<br>10,000A|250V<br>250V<br>125V<br>32V<br>250V<br>125V<br>32V| Cross-reference: For applicable cross-reference see table V. The existing stocks of superseded items may be used. When exhausted, the superseding parts shall be used. 7 TABLE V. Cross reference. |||TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.|TABLE V.Cross reference<br>.| |---|---|---|---|---|---|---|---|---|---|---| |8|Superseding<br>number|Superseded numbers for CAGE||||||||| |||81349|81349|96906|71400|71400|75915|75915|75915|98997| ||F02A250V1/100A1<br>/<br>F02A250V1/32A<br>F02A250V1/16A<br>F02A250V1/8A<br>F02A250V15/100A<br>F02A250V175/1000A<br>F02A250V3/16A<br>F02A250V2/10A<br>F02A250V1/4A<br>F02A250V3/10A<br>F02A250V3/8A<br>F02A250V1/2A<br>F02A250V6/10A<br>F02A250V3/4A<br>F02A250V1A<br>F02A250V1 1/4A<br>F02A250V1 1/2A<br>F02A250V1 6/10A<br>F02A250V2A<br>F02A250V2 1/2A<br>F02A250V3A<br>F02A250V4A<br>F02A250V5A<br>F02A250V6A<br>F02A125V8A<br>F02A250V10A<br>F02A32V15A<br>F02A32V20A<br>F02A32V25A<br>F02A32V30A|F02GR010A1<br>/<br>F02GR031A<br>F02GR062A<br>F02GR125A<br>F02G2R250A<br>F02GR375A<br>F02GR500A<br>F02GR750A<br>F02G1R00A<br>F02G1R50A<br>F02G2R00A<br>F02G3R00A<br>F02G4R00A<br>F02G5R00A<br>F02G6R00A<br>F02A32V8A<br>F02A32V10A|F02CR0101<br>/<br>F02CR031<br>F02CR062<br>F02CR125<br>F02CR250<br>F02CR375<br>F02CA500<br>F02CR750<br>F02C1R00<br>F02C1R50<br>F02C2R00<br>F02C3R00<br>F02C4R00<br>F02C5R00<br>F02C6R00<br>F02D8R00<br>F02D10R0<br>F02A15R0<br>F02A20R0<br>F02A25R0<br>F02A30R0|MS90078-12<br>/<br>MS90078-2<br>MS90078-3<br>MS90078-4<br>MS90078-5<br>MS90078-6<br>MS90078-7<br>MS90078-8<br>MS90078-9<br>MS90078-10<br>MS90078-11<br>MS90078-12<br>MS90078-13<br>MS90078-14<br>MS90078-15|AGC1/100<br>AGC1/32<br>AGC1/16<br>AGC1/8<br>AGC15/100<br>AGC175/1000<br>AGC3/16<br>AGC2/10<br>AGC1/4<br>AGC3/10<br>AGC3/8<br>AGC1/2<br>AGC6/10<br>AGC3/4<br>AGC1<br>AGC1 1/4<br>AGC1 1/2<br>AGC1 6/10<br>AGC2<br>AGC2 1/2<br>AGC3<br>AGC4<br>AGC5<br>AGC6<br>AGC8<br>AGC10<br>AGC15<br>AGC20<br>AGC25<br>AGC30|MGB1/16<br>MGB1/8<br>MTH4<br>MTH5<br>MTH6<br>GLH8<br>GLH10|311.010<br>311.031<br>311.062<br>311.125<br>311.150<br>311.175<br>311.187<br>311.200<br>311.250<br>311.300<br>311.375<br>311.500<br>311.600<br>311.750<br>311001<br>3111.25<br>3111.50<br>3111.60<br>311002<br>31102.5<br>311003<br>311004<br>311005<br>311006|312.010<br>312.031<br>312.062<br>312.125<br>312.150<br>312.175<br>312.187<br>312.200<br>312.250<br>312.300<br>312.375<br>312.500<br>312.600<br>312.750<br>312001<br>3121.25<br>3121.50<br>3121.60<br>312002<br>31202.5<br>312003<br>312004<br>312005<br>312006|392.010<br>392.031<br>392.062<br>392.125<br>392.150<br>392.175<br>392.187<br>392.200<br>392.250<br>392.300<br>392.375<br>392.500<br>392.600<br>392.750<br>392001<br>3921.25<br>3921.50<br>3921.60<br>392002<br>39202.5<br>392003<br>392004<br>392005<br>392006|3AG1/100<br>3AG1/32<br>3AG1/16<br>3AG1/8<br>3AG15/100<br>3AG175/100<br>3AG3/16<br>3AG2/10<br>3AG1/4<br>3AG3/100<br>3AG3/8<br>3AG1/2<br>3AG6/10<br>3AG3/4<br>3AG1<br>3AG1 1/4<br>3AG1 1/2<br>3AG1 6/10<br>3AG2<br>3AG2 1/2<br>3AG3<br>3AG4<br>3AG5<br>3AG6| 1/ See notes at end of table. ## MIL-PRF-15160/2H TABLE V. Cross reference – Continued. ||TABLE V.Cross reference<br> – Continued.|TABLE V.Cross reference<br> – Continued.|TABLE V.Cross reference<br> – Continued.|TABLE V.Cross reference<br> – Continued.|TABLE V.Cross reference<br> – Continued.|TABLE V.Cross reference<br> – Continued.| |---|---|---|---|---|---|---| |Superseding<br>number|Superseded numbers for CAGE|||||| ||81349|96906|71400|75915|75915|98997| |F02B250V1/100A1<br>/<br>F02B250V1/32A<br>F02B250V1/16A<br>F02B250V1/10A<br>F02B250V1/8A<br>F02B250V15/100A<br>F02B250V3/16A<br>F02B250V2/10A<br>F02B250V1/4A<br>F02B250V3/10A<br>F02B250V3/8A<br>F02B250V4/10A<br>F02B250V1/2A<br>F02B250V6/10A<br>F02B250V7/10A<br>F02B250V3/4A<br>F02B250V8/10A<br>F02B250V1A<br>F02B250V1 1/4A<br>F02B250V1 1/2A<br>F02B250V1 6/10A<br>F02B250V2A<br>F02B250V2 1/2A<br>F02B250V2 8/10A<br>F02B250V3A<br>F02B250V3 2/10A<br>F02B250V4A<br>F02B250V5A<br>F02B250V6 1/4A<br>F02B32V7A<br>F02B32V8A<br>F02B32V10A<br>F02B32V12A<br>F02B32V15A<br>F02B32V20A<br>F02B32V25A<br>F02B32V30A|F02GR010B1<br>/<br>F02GR031B<br>F02GR062B<br>F02GR0125B<br>F02GR250B<br>F02GR0375B<br>F02GR500B<br>F02GR750B<br>F02G1R00B<br>F02D1R50B<br>F02D2R00B<br>F02D3R00B<br>F02D8R00B|MS90078-16 2/<br>MS90078-17<br>MS90078-18<br>MS90078-19<br>MS90078-20<br>MS90078-21<br>MS90078-22<br>MS90078-23<br>MS90078-24<br>MS90078-25<br>MS90078-26<br>MS90078-27|MDL1/100<br>MDL1/32<br>MDL1/16<br>MDL1/10<br>MDL1/8<br>MDL15/100<br>MDL3/16<br>MDL2/10<br>MDL1/4<br>MDL3/10<br>MDL3/8<br>MDL4/10<br>MDL1/2<br>MDL6/10<br>MDL7/10<br>MDL3/4<br>MDL8/10<br>MDL1<br>MDL1 1/4<br>MDL1 1/2<br>MDL1 6/10<br>MDL2<br>MDL2 1/2<br>MDL2 8/10<br>MDL3<br>MDL3 2/10<br>MDL4<br>MDL5<br>MDL6 1/4<br>MDL7<br>MDL8<br>MDL10<br>MDL12<br>MDL15<br>MDL20<br>MDL25<br>MDL30|393.010<br>393.031<br>393.062<br>393.125<br>393.250<br>393.375<br>393.500<br>393.750<br>393.001|313.010<br>313.031<br>313.062<br>313.100<br>313.125<br>313.150<br>313.187<br>313.200<br>313.250<br>313.300<br>313.375<br>313.400<br>313.500<br>313.600<br>313.700<br>313.750<br>313.800<br>313001<br>3131.25<br>31301.5<br>31301.6<br>313002<br>31302.5<br>31302.8<br>313003<br>31303.2<br>313004<br>313005<br>3136.25<br>313007<br>313008<br>313010<br>313012<br>313015<br>313020<br>313025<br>313030|3AGTL1/100A-250V<br>3AGTL1/32A-250V<br>3AGTL1/16A-250V<br>3AGTL1/10A-250V<br>3AGTL1/8A-250V<br>3AGTL15/100A-250V<br>3AGTL3/16A-250V<br>3AGTL2/10A-250V<br>3AGTL1/4A-250V<br>3AGTL3/10A-250V<br>3AGTL3/8A-250V<br>3AGTL4/10A-250V<br>3AGTL1/2A-250V<br>3AGTL6/10A-250V<br>3AGTL7/10A-250V<br>3AGTL3/4A-250V<br>3AGTL8/10A-250V<br>3AGTL1A-250V<br>3AGTL11/4A-250V<br>3AGTL11/2A-250V<br>3AGTL16/10A-250V<br>3AGTL2A-250V<br>3AGTL21/2A-250V<br>3AGTL28/10A-250V<br>3AGTL3A-250V<br>3AGTL3 2/10A-250V<br>3AGTL4A-250V<br>3AGTL5A-250V<br>3AGTL8A32V<br>3AGTL10A32V<br>3AGTL12A32V<br>3AGTL20A32V| 1/ A letter “S” following the part number signifies silver plating. 2/ A second dash number (-1) signifies silver plating. Referenced documents. In addition to MIL-PRF-15160, this document references the following: ## MIL-STD-202 The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. 9 MIL-PRF-15160/2H Custodians: Army - CR Navy - SH Air Force - 85 DLA - CC Preparing activity: DLA - CC (Project 5920-2008-037) Review activities: Army - AR, AT, CR4, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil. 10
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →