EZAC-RM-1
SENSORS
- Manufacturer: BANNER ENGINEERING
- Product type:
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 180.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [5 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> ®<br>**----- End of picture text -----**<br> ## **Models EZAC-RM-1 and EZAC-RM-2 Relay Modules** _Replacement Relay Modules for the EZ-SCREEN[®] AC Interface Box_ ## ~~**Overview**~~ Models EZAC-RM-1 and EZAC-RM-2 are replacement relay modules for the Banner EZ-SCREEN[®] AC Interface Box. Refer to the table below for correct models. Relay module replacement requires only a screwdriver; replacement instructions follow. |**EZAC Box**<br>**Model Number**|**Replacement Output Relay**<br>**Contact Module Model**| |---|---| |**EZAC-R9-QE8**|EZAC-RM-1| |**EZAC-R10N-QE8-QS53**|| |**EZAC-R11-QE8**|EZAC-RM-2| |**EZAC-R15A-QE8-QS83**|| |**EZAC-R8N-QE8-QS53**|| **==> picture [33 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 122369<br>**----- End of picture text -----**<br> Printed in USA P/N 122369 rev. A 08/05 ## **Models EZAC-RM-1 and EZAC-RM-2 Rela Modules y** **==> picture [345 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> 6-Position Terminal<br>Terminal Plug Board<br>Relay<br>Module 4 x #4-40<br>Board Sems Screws<br>**----- End of picture text -----**<br> **==> picture [47 x 40] intentionally omitted <==** **----- Start of picture text -----**<br> !<br>**----- End of picture text -----**<br> **WARNING . . . Remove Power Before Maintenance** ~~Before pe~~ rforming any maintenance inside the AC Interface Box, always remove all power from the Box and from the machinery to which the Box is connected. **Failure to do so can result in electrical shock and serious injury or death.** **Figure 1. Internal board layout** ## ~~**Removing the Old Module**~~ 1. Disconnect the AC power from the AC Interface Box. Verify that the Power LED is OFF. 2. Disconnect any power connected to the relay’s N.O. Safety contacts, and to the N.C. Output contact. 3. Remove the Box front cover. 4. Remove the plug-in connector from the old relay module board. 5. Unscrew the screws at the 4 corners of the board. 6. Unplug the complete relay module board from the terminal board. ## ~~**Installing the New Module**~~ 1. Plug the new relay module board into the terminal board. 2. Fasten the four screws in the corners. 3. Plug the connector into the relay module board. 4. Close the Box cover and secure. 5. Connect AC power to the AC Interface Box. 6. Perform your machine checkout procedure, to guarantee proper function. **==> picture [166 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> ®<br>**----- End of picture text -----**<br> **WARRANTY:** Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 122369 rev. A Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
Updated at June 9, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.