Image not available
Illustrative purposes only
EZ480D18S
Solid State Relay, w/ Internal Snubber, SPST-NO, 18 A, 660 VAC, Panel Mount, Quick Connect
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (21-Jan-2025)
- Load Current: 18A
- Product Range: EZ Series
- Relay Mounting: Panel Mount
- Switching Mode: Zero Voltage Turn On
- Relay Terminals: Quick Connect
- Control Voltage Max: 15VDC
- Control Voltage Min: 4VDC
- Contact Configuration: SPST-NO
- Operating Voltage Max: 660VAC
- Operating Voltage Min: 48VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 54.54 € |
| Current stock | 10+ |
| Lead time | 24 days |
## **| EZ SERIES** ## PANEL MOUNT SOLID STATE RELAYS ## Features - Compact design for low-profile applications - Ratings from 5 A to 18 A @ 600 VAC - SCR output for heavy industrial loads - AC or DC control - 1/4” fast-on terminals for easy installation - UL/CSA/TUV Approved, CE Compliant to EN60950-1 ## **PRODUCT SELECTION** |**Control Voltage**|**5 A**|**12 A**|**18 A**| |---|---|---|---| |**3-15 VDC**|EZ240D5|EZ240D12|EZ240D18| |**15-32 VDC**||EZE240D12|EZE240D18| |**90-140 VAC**||EZ240A12|EZ240A18| |**18-36 VAC**||EZE240A12|EZE240A18| |**4-15 VDC**||EZ480D12|EZ480D18| |**15-32 VDC**||EZE480D12|EZE480D18| |**90-140 VAC**||EZ480A12|EZ480A18| Page 1 Copyright © 2024 Sensata Technologies, Inc. ## **SPECIFICATIONS** ## Output[(1)] **==> picture [540 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> Description 5 A 12 A 18 A 12 A 18 A<br>Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 24-280 48-660 48-660<br>Transient Overvoltage [Vpk] 600 600 600 1200 1200<br>Maximum Off-State Leakage Current @ Rated Voltage [mArms] [(4)] 0.1 0.1 0.1 0.1 0.1<br>Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] [(2)] 500 500 500 500 500<br>Maximum Load Current [Arms] [(3)] 5 12 18 12 18<br>Minimum Load Current [Arms] 150 150 150 150 150<br>Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 38/40 143/150 191/200 143/150 191/200<br>Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.5 1.5 1.5 1.5 1.5<br>Thermal Resistance Junction to Case (Rjc) [°C/W] 2 2 1.1 2 1.1<br>Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A² sec] 102/93 102/93 182/166 102/93 182/166<br>Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5 0.5<br>**----- End of picture text -----**<br> ## Input[(1)] **==> picture [542 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> Description EZ240Dxx EZ480Dxx EZExxxDxx EZxxxAxx EZExxxAxx<br>Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 Vrms 18-36 Vrms<br>Minimum Turn-On Voltage 3.0 VDC 4.0 VDC 15.0 VDC 90.0 Vrms 18.0 Vrms<br>Minimum Turn-Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC 10.0 Vrms 2.0 Vrms<br>Nominal Voltage 5.0 VDC 5.0 VDC 24 VDC 120 Vrms 24 Vrms<br>Typical Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mA 10 mA<br>Nominal Input Impedance 300 Ohms 240 Ohms 1500 Ohms 10.6K Ohms 1800 Ohms<br>Maximum Turn-On Time [msec] [(5)] 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle<br>Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle<br>**----- End of picture text -----**<br> ## General[(1)] **==> picture [541 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output/Base (50/60 Hz) 2500 Vrms<br>Minimum Insulation Resistance (@ 500 VDC) 10 [9] Ohms<br>Maximum Capacitance, Input/Output 8 pF<br>Ambient Operating Temperature Range -40 to 80°C<br>Ambient Storage Temperature Range -40 to 125 °C<br>Weight (typical) 1.5 oz (43 g)<br>Encapsulation Thermally Conductive Epoxy<br>Terminals .25” Fastons<br>Mounting Screw Torque Range (8-32 UNC screw) [lb-in/<br>8-14/1.1-1.5<br>Nm]<br>**----- End of picture text -----**<br> Page 2 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **MECHANICAL SPECIFICATIONS** Tolerance: ±0.02 in / 0.5 mm All dimensions are in inches [millimeters] ## **WIRING DIAGRAM** Page 3 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **THERMAL DERATE INFORMATION** **==> picture [499 x 308] intentionally omitted <==** Page 4 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com e **ORDERING OPTIONS** Dee Example : EZ240D18RS l **EZ E 240 A 12 R S Series** e ~~e | |} Ld~~ **EZ Input Range** ee es ee **Blank :** Standard Input **E :** 18-36 VAC (AC Input), 15-32 VDC (DC Input) **Operating Voltage** esee **240 :** 24-280 VAC **480 :** 48-660 VAC **Control Voltage** pf **D :** 3-15 VDC (4-15 VDC for 480 V) **A :** 90-140 VAC **Load Current** | **5 :** 5 Amps (EZ240D suffix only) **12 :** 12 Amps **18 :** 18 Amps **Switching Mode Blank :** Zero Voltage Turn-On **R :** Instantaneous Turn-On **Internal Snubber Blank :** Not Included Required for valid part number S **S :** Included (240 V only) ~~E~~ For options only and not required for valid part number ## **GENERAL NOTES** (1) All parameters at 25°C unless otherwise specified. (2) Off-state dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Heat sinking required, see derating curves. (4) Off- state leakage for snubbered version (suffix S, 240V version only) is 10.0mArms (5) Turn-on time for Instantaneous turn-on versions is 0.1 msec (DC Control Models). ## **AGENCY APPROVALS & CERTIFICATIONS** Designed in accordance with the requirements of IEC 62314 EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Page 5 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com **WARNINGS** ## RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** ## HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (800) 350 2727 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Page 6 www.sensata.com Rev:07/25/24 ECN 21039 FDE-07-01 Rev. B Copyright © 2024 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →