Image not available
Illustrative purposes only
ETM1411-2307
Panel Mount Timer, Digital, 184 VAC, 253 VAC, 0.01 min, 99.59 h, 29 mm, 71 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CAL CONTROLS
- Product type: Hour Meters
- Time Max: 99.59h
- Time Min: 0.01min
- Panel Cutout Width: 71mm
- Supply Voltage Max: 253VAC
- Supply Voltage Min: 184VAC
- Panel Cutout Height: 29mm
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 60.13 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL SPECIFICATIONS**
Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product.
**ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50°C/-25 ... +70°C (with no icing)** So **Max. Relative humidity 80% up to 31°C decreasing linearly 50% at 40°C. Rated pollution degree According to EN 60529 Front panel : IP60 Rear panel : Ip20** ——E—E——e **Height** | **Max. 2000m**
## **CAL ETM1411 DIGITAL TIMER**
**Do not use the device in locations subject to corrosive and flammable gases.**
Thank you for choosing the CAL ETM1411 digital timer.
## **ELECTRICAL CHARACTERISTICS**
- **34 x 77mm sized.**
**==> picture [793 x 442] intentionally omitted <==**
**----- Start of picture text -----**<br>
* Single contact output for timing control. Supply 230V AC +%10 -%20, 50/60Hz or 24V AC/DC ± %10, 50/60Hz or 12V AC/DC ± %10, 50/60Hz.<br>* External start input. C 6 ETM1411 START Power consumption Max 3VA<br>** 0:01 .... 99:59 min.Display can be adjusted to show min. or sec.Scale ; OUT HOUR MIN SET WiringScaleSensitivity 2.5mm² screw-terminal connections1 sec.Selectable 99:59 min. or hour.<br>Time Accuracy ± %1<br>0:01 .... 99:59 hour<br>* 5959 BV:Nee Indicator 4 digits, 12mm, 7 parts yellow LED<br>*** Decrease and increace step of time can be adjusted.Start and stop possibility by front panel.16 different warning tones.Upper and lower limits of the setpoint can be adjusted. CAL DIGITAL TIMER STOP Safety requirementsEMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.The device is designed to operate in controlled electromagnetic environment)EN 61010-1: 2001 (pollution degree 2, overvoltage category II)<br>* CE marked according to European Norms. OUTPUT<br>OUT Relay: 250V AC, 8A (for resistive load), NO+NC<br>Life expectancy for relay Mechanical 30.000.000 operation; Electrical 100.000 operation<br>Output Supply Voltage Order Code<br>230V AC +%10 -%20 ETM1411-230VAC<br>START INPUT<br>Relay 12V AC/DC ±%10 ETM1411-12 Input type Control with mechanical contact.<br>24V AC/DC ±%10 ETM1411-24 On and Off times for input pulses Min. = 100ms, Max. =<br>Connection Diagram HOUSING<br>CAL ETM1411 is intended for installation in control panels. Make sure that the device is Housing type Suitable for panel mounting<br>used only for intended purpose. The shielding must be grounded on the instrument side. Dimensions W77xH34xD70mm<br>During an installation, all of the cables that are connected to the device must be free of Weight Approx. 240g (after packing)<br>— Enclosure material SYS Self extinguishing plastics<br>electrical power. The device must be protected against inadmissible humidity, vibrations,<br>severe soiling and make sure that the operation temperature is not exceeded. All input and While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.<br>output lines that are not connected to the supply network must be laid out as shielded and<br>twisted cables. These cables should not be close to the power cables or components. The<br>AN a<br>installation and electrical connections must be carried out by qualified staff and must be Dimensions<br>according to the relevant locally applicable regulations. 85mm Depth 70mm 8mm<br>For removing mounting clamps:<br>www.cal-controls.com www.cal-controls.com ETM1411 START<br>= ETM1411-230VAC Go" ETM1411-12 ee OUT HOUR MIN Push out the mounting clampin direction 1 as shown =<br>SN: XXXXXXXXXDIGITAL TIMER SN: XXXXXXXXXDIGITAL TIMER s Equipment is protected throughoutby DOUBLE INSULATION. SET in the figure below. Then, pull<br>1 GEER). y out the clamp in direction 2. |<br>CAL DIGITAL TIMER STOP<br>c é c e Holding screw — = 2<br>0.4-0.5Nm mounting mounting Panel Rubber<br>clamp clamp gasket<br>START START 1<br>: |- a.<br>= V2 hy Vp Panel cut-out Note:1) Panel thickness<br>1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 71mm should be maximum<br>Me a Lak 2 ¢ ° g {_SisUUsisUUUsisis 7 mm.<br>2) If there is no 60mm<br>¢ 3 ) free space at the back<br>NOTE : Fuse Note: side of the device, itwould be difficult to<br>SUPPLY: F 100 mA 1) Mains supply cords shall meet the requirements of<br>250V AC Switch IEC 60227 or IEC 60245. remove it from the panel.<br>184-253V AC 7 Line 230V AC 2) In accordance with the safety regulations, the power<br>50/60Hz 3VA 8 Neutral Supply supply switch shall bring the identification of<br>Fuse shouldbe connected. Cable size: 1,5mm² the relevant instrument and it should be easily accessibleby the operator. CAL CONTROLS LTD<br>OUT 250V AC 8A RESISTIVE LOAD OUT 250V AC 8A RESISTIVE LOAD<br>3VA 3VA<br>230V AC +10% -20% 50/60Hz 12V AC/DC ±10% 50/60Hz<br>29mm<br>34mm<br>50/60Hz OUT<br>3VA<br>250V AC 8A<br>230V AC +10% -20% RESISTIVE LOAD<br>www.cal-controls.com<br>12 11 10 9 8 7 6 5 4 3 2 1<br>START<br>SN: XXXXXXXXX<br>DIGITAL TIMER<br>ETM1411-230VAC<br>**----- End of picture text -----**<br>
**CAL CONTROLS LTD Bury Mead Road, Hitchin, Herts, SG5 1RT, UK. Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales@cal-controls.co.uk Web : www.cal-controls.com**
**1/2**
**ETM1411-E-03**
**==> picture [130 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
INDICATOR OF INDICATOR OF<br>INDICATOR OFCONTACT OUTPUT SELECTINGHOUR SELECTINGMINUTE<br>**----- End of picture text -----**<br>
**Displayed time value in the run mode, parameter value or name in the programming mode.**
**When held down for one second in the run mode, timer runs. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.**
**==> picture [748 x 501] intentionally omitted <==**
**----- Start of picture text -----**<br>
ETM1411 START<br>OUT HOUR MIN run mode. When held down for a few seconds, the change rate accelerates.<br>SET<br>When held down for one second in the run mode, timer and voiced warning are stopped.(When Str.t. = TYP.1 mode is selected, timer and voiced warning can be stopped if external start input is off). Used<br>CAL DIGITAL TIMER STOP for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.<br>Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. For adjusting the selected parameter, while holding key, the value can be<br>adjusted by using and keys.<br>av =<br>CONTROL DIAGRAM BY EXTERNAL START INPUT<br>Run Mode<br>Out.t. TYP.0 TYP.1<br>30 1000 59 Timevalue 60 00 59 59 60 00 Str.t.<br>Power<br>When pressed key, TIMER set value flashes and by using and keys the value can be adjusted Out<br>with the step defined byIn.de. TYP.0 Startinput<br>Stop<br>key<br>If key is pressed and held for 3 seconds, If key is pressed,<br>programming mode is entered. run mode is entered. Indicator<br>Programming Mode Power<br>T.S. T.c. SE Out<br>a TYP.1 Start<br>input<br>T.lol The lower limitof the setpoint.Adjustable between0.01 and T.uPl. T.bas adjutable max. 99:59 h.Selection of time unit.Ifadjutable max. 99:59 min.If minHouris selected, time can beis selected, time can be S.Cod. Access code for enteringsecurity menu.This parameter should be 411. CONTROL DIAGRAM BY START & STOP KEYSIndicator<br>Selection of start type.<br>T.uPl The upper limitof the setpoint. Str.t. By external start input andstart/stop keys, timer can be run A. - t.S. Access code for timer set menuNonE= Menu is invisible. Out.t. TYP.0 TYP.1<br>Adjustable betweenT.lol and 99.59. and stopped. 4 different selectiontypes are defined in the P.yes= Parameters of menuare changeable. Str.t. Power<br>control diagram. P.no= Parameters of menu<br>Increase or decrease Selection of relay output. are only visible. Out<br>In.de step of the setpoint. Out.t. If typ.0 is selected, timer runs Start<br>Adjustable between1 and 30. by start and relay contactWhen time is over, relay contactshuts. Access code for TYP.2 key<br>opens. Ifruns by start.typ.1When time is over,is selected, timer A. - T.c . timer configuration menu.NonE= Menu is invisible. Stopkey<br>relay contact shuts. P.yes= Parameters of menu<br>Sond. Selection of buzzer voice type.Adjustable 16 different voice types. P.no= Parameters of menuare changeable. Indicator<br>If this parameter is selected 0, are only visible.<br>voiced warning is canceled. Power<br>Out<br>Start<br>TYP.3 key<br>Stop<br>key<br>Indicator<br>| e pee<br>SET<br>SET SET<br>SET<br>SET SET<br>: : : :<br>**----- End of picture text -----**<br>
**ETM1411-E-03**
**2/2**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →