Image not available
Illustrative purposes only
ESR5-NO-41-24VAC-DC
Safety Relay, 24 VDC, 4PST-NO, ESR5 Series, DIN Rail, 4 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON MOELLER
- Product type: Safety Relays
- Available until stocks are exhausted
- SVHC: No SVHC (17-Dec-2015)
- IP Rating: IP20
- Coil Voltage: 24VDC
- Product Range: ESR5 Series
- Relay Mounting: DIN Rail
- Contact Current: 4A
- Relay Terminals: Screw
- Contact Material: -
- Contact Configuration: 4PST-NO
- Contact Voltage AC Nom: 230V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 204.45 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - ESR5-NO-41-24VAC-DC** ## **Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths** **Part no. ESR5-NO-41-24VAC-DC 118701 EL Number 4133317 (Norway)** ## |**118701**<br>**EL Number**<br>**(Norway)y)) **<br>**4133317**<br>C|||| |---|---|---|---| |**General specifications**|||| |**General specifications**<br>Product name|||Eaton ESR5 Safety relay| |Part no.|||ESR5-NO-41-24VAC-DC| |EAN|||4015081168415| |Product Length/Depth|||114.5 millimetre| |Product height|||99 millimetre| |Product width|||22.5 millimetre| |Product weight|||0.218 kilogram| |Certifications|||Machines 2006/42/EG<br>IEC/EN 60204<br>UL report applies to both US and Canada<br>Certified by UL for use in Canada<br>EN ISO 13849-1<br>2014/30/EU<br>CE<br>UL 508<br>IEC 62061<br>IEC 61508, Parts 1-7<br>EN 50178<br>UL Category Control No.: NKCR; NKCR7<br>UL File No.: E29184<br>CSA-C22.2 No. 14-95<br>UL<br>CSA Class No.: 3211-83; 3211-03| |Product Tradename|||ESR5| |Product Type|||Safety relay| |Product Sub Type|||None| |**Features & Functions**|||| |Electric connection type|||Screw connection| |Features|||Basic insulation<br>Safe insulation<br>Manual start<br>6 kV between input circuit / NC contacts, and enable current paths<br>Reinforced insulation<br>Automatic start<br>4 Non-delayed enable current paths| |Fitted with:|||Approval according to UL<br>Start input<br>Detachable clamps<br>Approval for TÜV<br>Feedback circuit| |Functions|||1-channel| |Material|||Contacts: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au)<br>Enclosure: Polyamide (PA), not reinforced| |**General information**|||| |Connection type|||M3 screw terminals| |Current consumption|||65 mA, DC<br>140 mA, AC| |Degree of protection|||Enclosure: IP20<br>Terminals: IP20<br>Installation location: ≥ IP54<br>IP20| |Duty factor|||100 %| |Emitted interference|||According to EN 61000-6-4| |Interference immunity|||According to EN 61000-6-2| |LED indicator|||Status indication of SmartWire-DT network: Green LED| |Lifespan, mechanical|||10,000,000 Operations| |Model|||Basic device| |Mounting method|||Top-hat rail fixing (according to IEC/EN 60715, 35 mm)<br>Rail mounting possible| 10/24/2024 Eaton 118701 ED2023 V1.0 EN 1 / 5 |Mounting width|||22.5 mm| |---|---|---|---| |Overvoltage category|||III| |Pollution degree|||2| |Power loss|||Normally 5.16 W| |Product category|||Electronic safety relays| |Protection|||Finger and back-of-hand proof, Protection against direct contact when actuated<br>from front (EN 50274)| |Rated impulse withstand voltage (Uimp)|||4000 V AC| |Recovery time|||1000 ms| |Safety parameter (EN ISO 13849-1)|||PL e possible only with the aid of fault exclusions<br>230,000 switching cycles, B10d<br>Cat. 1, Category<br>PL c, Performance level| |Safety parameter (IEC 62061)|||4.05 x 10-10, PFHd, Probability of failure per hour<br>Cat. 1, Category<br>SILCL 1, Safety integrity level claim limit<br>SIL 1, Safety integrity level, In accordance with IEC 61508| |Stop category (IEC 60204)|||0| |Suitable for|||Safety relay for monitoring emergency stop and protective door switch<br>Monitoring of emergency-stop circuits<br>Monitoring of position switches<br>Module used to safely interrupt electrical circuits| |Switching frequency|||Max. 0.5 Hz, Input data| |Type|||Protective door<br>Feedback circuit<br>Emergency stop category 0; emergency switching of| |**Ambient conditions, mechanical**|||| |Mounting position|||As required| |Prooftest|||167 Months (Low Demand)<br>240 Months (High Demand)| |Switching capacity|||2.5 A at 3600 O/h, DC-13 at 24 V, Outputs<br>4 A at 360 O/h, DC-13 at 24 V, Outputs<br>In accordance with IEC 60947-5-1, Outputs<br>4 A at 360 O/h, AC-15 at 230 V, Outputs<br>0.4 W<br>3 A at 3600 O/h, AC-15 at 230 V, Outputs| |Vibration resistance|||10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)| |**Climatic environmental conditions**|||| |Air pressure|||795 - 1080 hPa (operation)| |Altitude|||Max. 2000 m| |Ambient operating temperature - min|||-20 °C| |Ambient operating temperature - max|||55 °C| |Ambient storage temperature - min|||-40 °C| |Ambient storage temperature - max|||70 °C| |Climatic proofng|||Damp heat, constant, to IEC 60068-2-3<br>Dry heat to IEC 60068-2-2| |Environmental conditions|||Condensation: Non-condensing<br>Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2,<br>No. 14-95| |Operating temperature - min|||-20 °C| |Operating temperature - max|||55 °C| |Relative humidity|||< 75 %| |**Terminal capacities**|||| |Terminal capacity|||1 x (0.2 – 2.5) mm², solid<br>24 - 12 AWG, solid or stranded<br>2 x (0.25 – 1) mm², fexible with ferrule<br>1 x (0.25 – 2.5) mm², fexible with ferrule<br>2 x (0.2 – 1) mm², solid| |Stripping length (main cable)|||7 mm| |Screwdriver size|||2, Terminal screw, Pozidriv screwdriver<br>0.6 x 3.5 mm, Terminal screws| |Tightening torque|||0.6 Nm, Screw terminals| |**Electrical rating**|||| |Inrush current|||0.025 - 6 A| |Power supply circuit|||3.4 W (AC operated 50/60 Hz)<br>1.6 W (DC operated)| 10/24/2024 Eaton 118701 ED2023 V1.0 EN 2 / 5 **==> picture [72 x 217] intentionally omitted <==** Rated control supply voltage (Us) at AC, 50 Hz - min Rated control supply voltage (Us) at AC, 50 Hz - max Rated control supply voltage (Us) at AC, 60 Hz - min Rated control supply voltage (Us) at AC, 60 Hz - max Rated control supply voltage (Us) at DC - min Rated control supply voltage (Us) at DC - max Rated insulation voltage (Ui) Rated operational voltage 0 V 26.4 V 20.4 V 24 V 0 V 24 V 250 V Approx. 24 V DC at input, starting and feedback circuit 230 V AC 24 V AC/DC (power supply) 2.3 A, Input data Fuse 6 A gL/gG, For output circuits, External Miniature circuit-breaker with characteristic C: 24 V AC/DC 6 A, For output circuits, External Short-circuit proof, 24 V, Fuse for control circuit supply, Control circuit Short-circuit current Short-circuit protection Short-circuit protection rating 6 A, Output fuse, Output data ## **Input/Output** |Rated control supply voltage (Us) at AC, 50 Hz - min|||0 V| |---|---|---|---| |Rated control supply voltage (Us) at AC, 50 Hz - max|||26.4 V| |Rated control supply voltage (Us) at AC, 60 Hz - min|||20.4 V| |Rated control supply voltage (Us) at AC, 60 Hz - max|||24 V| |Rated control supply voltage (Us) at DC - min|||0 V| |Rated control supply voltage (Us) at DC - max|||24 V| |Rated insulation voltage (Ui)|||250 V| |Rated operational voltage|||Approx. 24 V DC at input, starting and feedback circuit<br>230 V AC<br>24 V AC/DC (power supply)| |Short-circuit current|||2.3 A, Input data| |Short-circuit protection|||Fuse 6 A gL/gG, For output circuits, External<br>Miniature circuit-breaker with characteristic C: 24 V AC/DC 6 A, For output circuits,<br>External<br>Short-circuit proof, 24 V, Fuse for control circuit supply, Control circuit| |Short-circuit protection rating|||6 A, Output fuse, Output data| |**Input/Output**|||| |Breaking power|||42 W max., inductive load (τ = 40 ms), at 110 V DC<br>110 W max., resistive load (τ = 0 ms), at 110 V DC<br>42 W max., inductive load (τ = 40 ms), at 48 V DC<br>42 W max., inductive load (τ = 40 ms), at 220 V DC<br>144 W max., resistive load (τ = 0 ms), at 24 V DC<br>288 W max., resistive load (τ = 0 ms), at 48 V DC<br>88 W max., resistive load (τ = 0 ms), at 220 V DC<br>42 W max., inductive load (τ = 40 ms), at 24 V DC<br>1500 VA, max., resistive load (τ = 0 ms), at 250 V AC| |Input|||∞ ms, Simultaneity for inputs 1/2| |Nominal current|||65 A| |Number of inputs|||One- and two-channel| |Number of outputs (safety related, delayed) with contact|||0| |Number of outputs (safety related, undelayed) with contact|||4| |Number of outputs (signaling function, delayed) with contact|||0| |Number of outputs (signaling function, undelayed) with contact|||1| |Permissible total cable resistance|||22 Ω (input and starting circuits for UN)| |Pick-up time|||20 ms typ.<br>65 ms typ. (K1, K2 - for UN automatic mode)| |Quadratic summation current|||72 A² (ITH² = I1² + I2² + I3² + I4²)| |Reset time|||45 ms| |Resistance|||22 Ω (impedance)| |Switching voltage|||250 V| |Uninterrupted current|||3 A N/C, Limiting continuous current<br>6 A N/O, Limiting continuous current| |**Design verifcation**|||| |<br>Equipment heat dissipation, current-dependent Pvid|||0 W| |Heat dissipation capacity Pdiss|||0 W| |Heat dissipation per pole, current-dependent Pvid|||0 W| |Rated operational current for specifed heat dissipation (In)|||0 A| |<br>Static heat dissipation, non-current-dependent Pvs|||5.16 W| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verifcation of thermal stability of enclosures|||Meets the product standard's requirements.| |<br>10.2.3.2 Verifcation of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |<br>10.2.3.3 Resist. of insul. mat. to abnormal heat/fre by internal elect. efects|||Meets the product standard's requirements.| |<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of assemblies|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| 10/24/2024 Eaton 118701 ED2023 V1.0 EN 3 / 5 |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |---|---|---|---| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 9.0** Relays (EG000019) / Device for monitoring of safety-related circuits (EC001449) Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Device for monitoring of safetyrelated circuits (ecl@ss13-27-37-18-19 [ACO304016]) |**Technical data ETIM 9.0**|**Technical data ETIM 9.0**|**Technical data ETIM 9.0**|**Technical data ETIM 9.0**| |---|---|---|---| |Relays (EG000019) / Device for monitoring of safety-related circuits (EC001449)|||| |Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Device for monitoring of safety-<br>related circuits (ecl@ss13-27-37-18-19 [ACO304016])|||| |Model|||Basic device| |Rail mounting possible|||Yes| |With detachable clamps|||Yes| |Type of electric connection|||Screw connection| |Voltage type (supply voltage)|||AC/DC| |Supply voltage AC 50 Hz||V|24 - 24| |Supply voltage AC 60 Hz||V|24 - 24| |Supply voltage DC||V|24 - 24| |Suitable for monitoring of position switches|||Yes| |Suitable for monitoring of emergency-stop circuits|||Yes| |Suitable for monitoring of valves|||No| |Suitable for monitoring of optoelectronic protection equipment|||No| |Suitable for monitoring of tactile sensors|||No| |Suitable for monitoring of magnetic switches|||No| |Suitable for monitoring of proximity switches|||No| |Evaluation inputs|||One- and two-channel| |Power consumption||W|5.16| |With start input|||Yes| |With muting function|||No| |With feedback circuit|||Yes| |Release-delay||s|0 - 0| |Type of control voltage 1|||AC/DC| |Control voltage 1||V|24 - 24| |Type of control voltage 2|||AC/DC| |Control voltage 2||V|24 - 24| |Number of outputs, safety related, undelayed, with contact|||4| |Number of outputs, safety related, delayed, with contact|||0| |Number of outputs, safety related, undelayed, semiconductors|||0| |Number of outputs, safety related, delayed, semiconductors|||0| |Number of outputs, signalling function, undelayed, with contact|||1| |Number of outputs, signalling function, delayed, with contact|||0| |Number of outputs, signalling function, undelayed, semiconductors|||0| |Number of outputs, signalling function, delayed, semiconductors|||0| |Voltage type (operating voltage)|||AC/DC| |Operating voltage AC 50 Hz||V|24 - 24| |Operating voltage AC 60 Hz||V|24 - 24| |Operating voltage DC||V|24 - 24| |Rated switch current||A|4| |Type of safety according to IEC 61496-1|||None| |Stop category according to IEC 60204|||0| 10/24/2024 Eaton 118701 ED2023 V1.0 EN 4 / 5 |Performance level according to EN ISO 13849-1|||Level c| |---|---|---|---| |SIL according to IEC 61508|||1| |With approval for BG BIA|||No| |With approval according to UL|||Yes| |Width||mm|22.5| |Height||mm|99| |Depth||mm|114.5| |With approval for TÜV|||Yes| Eaton Industries GmbH © 04/2023 by Eaton Industries GmbH Eaton 118701 ED2023 V1.0 EN 10/24/2024 5 / 5
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →