Image not available
Illustrative purposes only
ESR5-NO-31-24VAC-DC
RELAY, SAFETY, 3PST-NO, 24VDC, 6A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Safety Relays
- Coil; RELAY, SAFETY, 3PST-NO, 24VDC, 6A; Coil Voltage:24VDC; Contact Configuration:3PST-NO; Product Range:ESR5 Series; Relay Mounting:DIN Rail; Contact Current:6A; Relay Terminals:Screw
- IP Rating: IP20
- Coil Voltage: 24VDC
- Product Range: ESR5 Series
- Relay Mounting: DIN Rail
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: -
- Contact Configuration: 3PST-NO
- Contact Voltage AC Nom: 24V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 537.26 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Control Relays and Timers **==> picture [39 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Safety Relays<br>**----- End of picture text -----**<br> ## **40.10 Safety Relays** |**Safety Relays**||**40**| |---|---|---| |Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**2**|**40**| |Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**2**|**40**| |Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**2**|| |Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**2**<br>**3**<br>**4**|**40**<br>**40**| |Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**7**|**40**| **Note:** Supplement to Volume 7—Motor Controls, Logic and Connectivity, CA08100008E, Tab 40. **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **1** Safety Relays ## 40.10[Control Relays and Timers] **40** **==> picture [39 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Safety Relays<br>**----- End of picture text -----**<br> ## **Product Description** Safety relays are intended to reliably monitor the signals from safety devices at all times and switch off quickly and reliably in an emergency. Single-channel and dual channel versions are available for the construction of safety applications. The internal logic of the safety relays monitors the safety circuits (emergency stop, guard door, and so on) and activates the enable paths in a fault-free condition. Upon actuation of the safety device or in the even of a fault, the enable paths are switched off. Any faults that occur in the control circuit, such as ground fault, cross connection fault or wire breakage are also detected. ## **Application Description** Eaton’s ESR5 safety relays provide optimal safety and a high degree of reliability on plant machinery. Applications that meet the highest safety requirements in accordance with EN 954-1, EN ISO 13849-1 up to PL e and accordance with IEC 62061 up to SILCL 3 can be realized with the ESR5 safety relay. Compatible with a wide variety of safety devices: - Emergency stops - Rope pulls - Two-hand control stations - Light curtain (OSSD) - Gate enable device - Safety switches ## **Contents** **==> picture [243 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Description|Page| |Safety Relays| |Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|3| |Technical Data and Specifications . . . . . . . . . . . . . . . . .|4| |Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|7| **----- End of picture text -----**<br> ## **Standards and** ## **Features** - UL 508; CSA-C22.2 No 14-95; CE Marked - Use for the highest safety requirements in accordance with EN 954-1 EN ISO 13849-1, IEC 62061 and EC 61508 - UL/cUL file number: E29184 - Degree of protection: IP20 - Suitable for the world market with UL, cUL certifications and TÜV Rhineland functional safety certifications - TÜV Rhineland certified - UL/cULus listed - Applicable for EN 60204 stop categories 0 or 1 - Plug-in screw terminals for fast and fault-free replacement - Multi-voltage versions (24–230 Vac/Vdc) for a flexible range of application - Delayed and non-delayed contact expansions accommodate a wide variety of applications **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **2** > Control Relays and Timers 40.10 Safety Relays ## **Product Selection** ## **Safety Relays** ## **Technical Overview** |**Technical Overview**|**Technical Overview**|**Technical Overview**||||||||||**40**| |---|---|---|---|---|---|---|---|---|---|---|---|---| ||||**Safety**||**Signal**|||**Removable**||||**40**| |**Single**<br>**Channel**|**Dual**<br>**Channel**|**Safety**<br>**Output (NO)**|**Output (NO)**<br>**(Delayed)**|**Output**<br>**Delay**|**Output**<br>**(NC)**|**Feedback**<br>**Output**|**Control**<br>**Voltage**|**Terminal**<br>**Blocks**|**Type of**<br>**Unit**|**Catalog Number**||**40**| |■<br>■|—<br>■|4<br>2|—<br>—|—<br>—|1<br>—<br>1<br>—<br>~~—,—_—~~||24 Vac/Vdc<br>24 Vac/Vdc|■<br>■|Main<br>Main|**ESR5-NO-41-24VAC-DC**<br>**ESR5-NO-21-24VAC-DC**||**40**| |■<br>■|■<br>■|3<br>3|—<br>—|—<br>—|1<br>1|—<br>—|24 Vac/Vdc<br>230 Vac|■<br>■|Main<br>Main|**ESR5-NO-31-24VAC-DC**<br>**ESR5-NO-31-230VAC**||**40**| |■|■|3|—|—|1|—|24–230 Vac/Vdc|■|Main|**ESR5-NO-31-AC-DC**||**40**| |■|■|2|2|0.1–30s|—|—|24 Vdc|■|Main|**ESR5-NV3-30**||| |—|■|2|—|—|1|—|24 Vac/Vdc|■|Main|**ESR5-NZ-21-24VAC-DC**||**40**| |■<br>■|—<br>—|5<br>—|—<br>4|—<br>0.3–3s|1<br>1|1<br>1|24 Vac/Vdc<br>24 Vdc|■<br>■|Expansion<br>Expansion|**ESR5-NE-51-24VAC-DC**<br>**ESR5-VE3-42**||**40**| ## **Application Overview** |**Emergency**|**Safety**|**Light Curtain/**|**Light Curtain/**|**Two-Hand Control**|**Contact**||**Cross Circuit**|**Monitored**||| |---|---|---|---|---|---|---|---|---|---|---| |**Stop**<br>■|**Switches**<br>■|**OSSD**<br>—|**OSSD**<br>®|**(EN 574 Type III C)**<br>—|**Expansion**<br>—|**Off-Delayed**<br>—|**Recognition**<br>—|**Manual Reset**<br>—|**Manual Reset**<br>@|**Catalog Number**<br>**ESR5-NO-41-24VAC-DC**| |■|■|—||—|—|—|■|—||**ESR5-NO-21-24VAC-DC**| |■|■|—||—|—|—|■|—||**ESR5-NO-31-24VAC-DC**| |■|■|—||—|—|—|■|■||**ESR5-NO-31-230VAC**| |■|■|—||—|—|—|■|■||**ESR5-NO-31-AC-DC**| |■|■|■||—|—|■|■|■||**ESR5-NV3-30**| |—<br>—|■<br>—|—<br>—||■<br>—|—<br>■|—<br>—|■<br>—|—<br>—||**ESR5-NZ-21-24VAC-DC**<br>**ESR5-NE-51-24VAC-DC**| |—|—|—||—|■|■|—|—||**ESR5-VE3-42**| |**Application Overview, continued**|**Application Overview, continued**|**Application Overview, continued**||||| |---|---|---|---|---|---|---| |**Single**|**Dual**|**Stop Category**|**Control Category**|**Achievable PL per**|**Achievable SIL per**|| |**Channel**|**Channel**|**EN 60204**|**to EN 954-1**|**ISO 13849-1**|**EN IEC 62061**|**Catalog Number**| |■|—|0|2|PL d|SIL 3|**ESR5-NO-41-24VAC-DC**| |■|■|0|4|PL e|SIL 3|**ESR5-NO-21-24VAC-DC**| |■|■|0|4|PL e|SIL 3|**ESR5-NO-31-24VAC-DC**| |■|■|0|4|PL e|SIL 3|**ESR5-NO-31-230VAC**| |■<br>■|■<br>■|0<br>0/1|4<br>4|PL e<br>PL e|SIL 3<br>SIL 3|**ESR5-NO-31-AC-DC**<br>**ESR5-NV3-30**| |—|■|0|4|PL e|SIL 3|**ESR5-NZ-21-24VAC-DC**| |■|—|0|4|PL e|SIL 3|**ESR5-NE-51-24VAC-DC**| |■|—|1|3|PL d|SIL 2|**ESR5-VE3-42**| ## _**Notes**_ Laser scanners or light curtains with OSSD outputs. All main units can also be reset automatically or manually. **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **3** Safety Relays ## 40.10[Control Relays and Timers] ## **Technical Data and Specifications** **40** |**Safety Relay**<br>**Description**|**Unit**|**ESR5-NO-21_**|**ESR5-NO-41_**|**ESR5-NO-31-24VAC-DC**|**ESR5-NZ-21_**| |---|---|---|---|---|---| |**General**<br>Standards||EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,| |||IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed| |Type-dependent standards<br>Lifespan, mechanical—c (contacts)|x 106|—<br>10|—<br>10|—<br>10|EN 574 Part no. IIIC<br>10| |Maximum operating frequency<br>Climatic proofng|Ops/h|3600<br>Cold according to|3600<br>Dry heat according to|3600<br>Cold according to|3600<br>Dry heat according to| |||EN 60068-2-1, dry heat|EN60068-2-2, damp heat|EN 60068-2-1, dry heat|EN60068-2-2, damp heat| |||according to EN60068-2-2,<br>damp heat according to|according to EN 60068-2-3|according to EN60068-2-2,<br>damp heat according to|according to EN 60068-2-3| |Ambient temperature|°F (°C)|EN 60068-2-3<br>–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|EN 60068-2-3<br>–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)| |Ambient temperature storage<br>Mounting position|°F (°C)|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any| |Vibration resistance (IEC/EN 60068-2-6)||2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2 g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm| |Shock resistance (IEC 60068-2-27)<br>Protection type||—|—|—|—| |Housing<br>Terminals||IP20<br>IP20|IP20<br>IP20|IP20<br>IP20|IP20<br>IP20| |Protection against direct contact when<br>actuated from front (IEC 0106 Part 100)||Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof| |Weight<br>Terminal capacity|kg|0.17|0.22|0.17|0.22| |Solid or fexible|mm2|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)| |Flexible with ferrule|mm2|1 x (0.25–2.5)|1 x (0.25–2.5)|1 x (0.25–2.5)|1 x (0.25–2.5)| |||2 x (0.25–1)|2 x (0.25–1)|2 x (0.25–1)|2 x (0.25–1)| |Solid or stranded|AWG|24–12|24–12|24–12|24–12| |Terminal screw|||||| |Pozidriv screwdriver|Size|2|2|2|2| |Flat-blade screwdriver|mm|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5| |Max. tightening torque|Nm|0.6|0.6|0.6|0.6| |**Main Contacts**|||||| |Rated impulse withstand voltage—Uimp<br>Overvoltage category/pollution degree|Vac|6000|4000|4000|6000| |Outside||III/2|III/2|III/2|III/2| |Inside||—|—|—|—| |Rated insulation voltage—Ui|Vac|250|250|250|250| |Rated operating voltage—Ue|Vac|230|230|230|230| |Rated operation current<br>AC-15|||||| |230V (360 ops./h)—Ie<br>230V (3600 ops./h)—Ie|A<br>A|5<br>3|4<br>3|5<br>3|4<br>3| |DC-13<br>24V (360 ops./h)—Ie|A|6|4|6|4| |24V (3600 ops./h)—Ie<br>Max. summation current of all poles|A|3|2.5|3|2.5| |24 Vac/Vdc devices<br>230 Vac devices|A<br>A|72<br>—|72<br>—|72<br>—|72<br>—| |Square of the total current<br>(and total current)||72 A2(6 + 6)|72 A2(4.2 + 4.2 + 4.2 + 4.2)|72 A2(4.9 + 4.9 + 4.9)|72 A2(6 + 6)| |of all current paths|||||| |Short-circuit protection|||||| |Max. fuse|A gG/gL|10|6|10|6| **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **4** > Control Relays and Timers 40.10 Safety Relays ## **Safety Relay, continued** |**Safety Relay, continued**|||||| |---|---|---|---|---|---| |**Description**|**Unit**|**ESR5-NO-21_**|**ESR5-NO-41_**|**ESR5-NO-31-24VAC-DC**|**ESR5-NZ-21_**| |**Power Supply Circuit**|||||| |Actuating voltage 50/60 Hz|Vac|24|24|24|24| |Actuating voltage—Us|Vdc|24|24|24|24| |Voltage tolerance pick-up voltage|xe|0.85–1.1|0.85–1.1|0.85–1.1|0.85–1.1| |Power consumption|||||| |AC operated 50/60 Hz|VA|—|—|—|—| |AC operated 50/60 Hz|W|3.4|3.4|3.4|3| |DC operated|W|1.6|1.6|1.6|1.5| |Fuse for control circuit supply|||||| |24V||Short-circuit proof|Short-circuit proof|Short-circuit proof|Short-circuit proof| |115/230V||—|—|—|—| |**Control Circuit**|||||| |Rated output voltage|Vdc|24|24|24|24| |Rated operational current<br>Resistance—R|mA|S12, S22: 30, S34: 45<br>50|S12: 65, S34: 40<br>22|S12, S22: 30, S34: 45<br>50|S11, S21: 60, Y2: 45<br>22| |Short-circuit current<br>Response time|A<br>ms|2.3<br>100|2.3<br>65|2.3<br>100|2.3<br>50| |Recovery time<br>Response time with reset monitoring—tA1|ms<br>ms|—<br>—|—<br>—|—<br>—|—<br>—| |Response time without reset monitoring—tA2<br>Reset time—tR/tR1|ms<br>ms|100<br>Single-channel 45;|65<br>45|100<br>Single-channel 45;|50<br>20| |Minimum on duration—tM|ms|dual-channel 10<br>—|—|dual-channel 10<br>—|—| |Recovery time—tW<br>Synchronous monitoring time—tS|ms<br>ms|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 1000<br>500| |**Electromagnetic Compatibility (EMC)**<br>Emitted interference||EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4| |Interference immunity||According to EN 61000-6-2,<br>EN 62061|According to EN 61000-6-2|According to EN 61000-6-2,<br>EN 62061|According to EN 61000-6-2| **40** **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **5** Safety Relays ## 40.10[Control Relays and Timers] ## **Safety Relay, continued** **40** |**Safety Relay, continued**||||||| |---|---|---|---|---|---|---| ||||**ESR5-NO-31-24V-**|||| |**Description**<br>**General**|**Unit**|**ESR5-NO-31-230VAC**|**230VAC-DC**|**ESR5-NV3_**|**ESR5-VE3_**|**ESR5-NE-51_**| |Standards||EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,| |||UL/CUL listed|UL/CUL listed|UL/CUL listed|UL/CUL listed|UL/CUL listed| |Type-dependent standards||EN 60204|EN 60204|EN 60204|—|—| |||(if applicable)|(if applicable)|(if applicable)||| |Lifespan, mechanical—c (contacts)|x 106|10|10|10|10|10| |Maximum operating frequency|Ops/h|3600|3600|3600|900|3600| |Climatic proofng||Dry heat according to|Dry heat according to|Cold in accordance with:|Dry heat according to|Dry heat according to| |||EN60068-2-2, damp heat|EN60068-2-2, damp heat|EN 60068-2-1, dry heat in|EN60068-2-2, damp heat|EN60068-2-2, damp heat| |||according to EN 60068-2-3|according to EN 60068-2-3|accordance with EN<br>60068-2-2, humidity|according to EN 60068-2-3|according to EN 60068-2-3| |||||storage test in accordance||| |||||with 60068-2-78||| |Ambient temperature|°F (°C)|–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|–4° to 113° (–20° to 45°)|–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)| |Ambient temperature storage|°F (°C)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)| |Mounting position||Any|Any|Any|Any|Any| |Vibration resistance (IEC/EN 60068-2-6)||2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,| |||amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm| |Shock resistance (IEC 60068-2-27)||—|—|—|—|—| |Protection type||||||| |Housing||IP40|IP40|IP20|IP20|IP20| |Terminals||IP20|IP20|IP20|IP20|IP20| |Protection against direct contact when<br>actuated from front (IEC 0106 Part 100)||Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof| |Weight|kg|0.3|0.3|0.17|0.17|0.22| |Terminal capacity||||||| |Solid or fexible|mm2|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)| |Flexible with ferrule|mm2|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)| |Solid or stranded|AWG|24–12|24–12|24–12|24–12|24–12| |Terminal screw||||||| |Pozidriv screwdriver|Size|2|2|2|2|2| |Flat-blade screwdriver|mm|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5| |Max. tightening torque<br>**Main Contacts**|Nm|0.6|0.6|0.6|0.6|0.6| |Rated impulse withstand voltage—Uimp<br>Overvoltage category/pollution degree|Vac|6000|6000|4000|4000|4000| |Outside<br>Inside||III/2<br>—|III/2<br>—|III/2<br>—|III/2<br>—|III/2<br>—| |Rated insulation voltage—Ui<br>Rated operating voltage—Ue|Vac<br>Vac|250<br>230|250<br>230|250<br>230|250<br>230|250<br>230| |Rated operation current<br>AC-15||||||| |230V (360 ops./h)—Ie<br>230V (3600 ops./h)—Ie|A<br>A|4<br>3|4<br>3|—<br>3|5<br>3|4<br>3| |DC-13||||||| |24V (360 ops./h)—Ie|A|4|4|—|6|4| |24V (3600 ops./h)—Ie|A|2.5|2.5|3|3|2.5| |Max. summation current of all poles||||||| |24 Vac/Vdc devices|A|50|50|49|50|50| |230 Vac devices|A|50|50|—|—|—| |Square of the total current<br>(and total current)||50 A2(4 + 4 + 4)|50 A2(4 + 4 + 4)|50 A2(4 + 4 + 4)|49 A2<br>(3.5 + 3.5 + 3.5 + 3.5)|50 A2<br>(3.7 + 3.7 + 3.7 + 3.7| |of all current paths<br>Short-circuit protection||||||+ 3.7)| |Max. fuse|A gG/gL|6|6|10|10|6| **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **6** > Control Relays and Timers 40.10 Safety Relays ## **Safety Relay, continued** |**Safety Relay, continued**||||||| |---|---|---|---|---|---|---| ||||**ESR5-NO-31-24V-**|||| |**Description**<br>**Power Supply Circuit**|**Unit**|**ESR5-NO-31-230VAC**|**230VAC-DC**|**ESR5-NV3_**|**ESR5-VE3_**|**ESR5-NE-51_**| |Actuating voltage 50/60 Hz<br>Actuating voltage—Us|Vac<br>Vdc|230<br>—|24–230<br>230|—<br>24|—<br>24|24<br>24| |Voltage tolerance pick-up voltage|xe|0.85–1.1|0.85–1.1|0.85–1.1|0.85–1.1|0.8–1.1| |Power consumption||||||| |AC operated 50/60 Hz<br>AC operated 50/60 Hz|VA<br>W|—<br>5.8|—<br>5.8|—<br>—|—<br>—|—<br>2.2| |DC operated|W|2.9|2.9|1.8|2|2.2| |Fuse for control circuit supply||||||| |24V||—|Short-circuit proof|—|—|—| |115/230V||Short-circuit proof|Short-circuit proof|—|—|—| |**Control Circuit**||||||| |Rated output voltage|Vdc|24|24|24|24|24| |Rated operational current|mA|S10, S12, S22: 35, S34,<br>S35: 45|S10, S12, S22: 35, S34,<br>S35: 45|S12, S22: 3.5, S34, S35: 7|A1, A2: 84, K1/K2: 5|A1, A2: 92| |Resistance—R||11|11|500|—|—| |Short-circuit current|A|0.7|0.7|0.1|—|—| |Response time|ms|250|250|150|20|20| |Recovery time|ms|—|—|—|—|—| |Response time with reset|ms|60|60|150|20|20| |monitoring—tA1||||||| |Response time without reset<br>monitoring—tA2|ms|250|250|150|20|20| |Reset time—tR/tR1|ms|20|20|20 (non-delayed enable<br>paths); 100 (min. delayed|0.3–3 s (+50%)<br>adjustable|20| |||||enable paths)||| |Minimum on duration—tM|ms|—|—|—|—|—| |Recovery time—tW<br>Synchronous monitoring time—tS|ms<br>ms|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 330<br>—|Approx. 1000<br>—|—<br>—| |**Electromagnetic Compatibility**<br>Emitted interference|**(EMC)**|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4| |Interference immunity||According to<br>EN 61000-6-2|According to<br>EN 61000-6-2|According to EN 61000-6-2,<br>EN 62061|According to<br>EN 61000-6-2|According to<br>EN 61000-6-2| **40** ## **Dimensions** Approximate Dimensions in Inches (mm) ## _**Safety Relays, Contact Expansion Modules**_ **ESR5_ 24 Vac/Vdc** **==> picture [222 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> 0.88<br>(22.5)<br>4.51<br>(114.5)<br>3.26 2.62 3.06 3.90<br>(82.8) (66.5) (77.6) (99.0)<br>3.74<br>0.26 (95.1)<br>(6.6)<br>**----- End of picture text -----**<br> ## **ESR5_ 230 Vac** **==> picture [229 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 1.77<br>(45.0) 4.51<br>(114.5)<br>3.26 2.62 3.06 3.90<br>(82.8) (66.5) (77.6) (99.0)<br>3.74<br>0.26 (95.1)<br>(6.6)<br>**----- End of picture text -----**<br> **Control Relays and Timers** CA04902001E—March 2011 www.eaton.com **7** **==> picture [101 x 34] intentionally omitted <==** Eaton’s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton’s full-scale engineering services, these products provide customerdriven PowerChain™ solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. **Eaton Corporation** Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com ©2011 Eaton Corporation All Rights Reserved Printed in USA Publication No. CA04902001E / Z10889 March 2011 PowerChain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. **==> picture [104 x 94] intentionally omitted <==** Eaton is a registered trademark of Eaton Corporation. All oher trademarks are property of their respective owners.
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →