Image not available
Illustrative purposes only
ES4P-221-DRXX1
Safety Relay, 24 VDC, DIN Rail, 8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON MOELLER
- Product type: Safety Relays
- SVHC: No SVHC (17-Dec-2015)
- Product Range: easySafety ES4P Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1681.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - ES4P-221-DRXX1** ## **Safety relay, 24 V DC, 14DI, 4DO relays, easyNet** **Part no. ES4P-221-DRXX1 Catalog No. 111018** **EL-Nummer 0004521513 (Norway)** ## **Delivery program** |**Catalog No.**<br>**111018**<br>**EL-Nummer**<br>**(Norway)y)) **<br>**0004521513**<br>**Deliveryy programrogramgramram**|||| |---|---|---|---| |Product range|||Control relays for safety applications| |Basic function|||easy800 with safety function blocks| |**Features**|||| |Safety functions|||Stopping in the event of an emergency<br>Protective door<br>OSSD input<br>ESPE with muting function<br>Two-hand control<br>Highest speed monitoring<br>Zero speed monitoring<br>Safety timing relay<br>Mode selection<br>Enabling switch<br>Feedback circuit| |Display & keypad|||**-**| |Mounting width||mm|107.5| |Technical safety parameters:|||| |Values according to EN ISO 13849-1|||| |Performance level|according<br>to EN ISO<br>13849-1||PL e| |Category|according<br>to EN ISO<br>13849-1||Kat. 4| |Safety integrity level claim limit|in accordance<br>with 62061||SILCL 3| |Probability of failure per hour|PFHd|x 10-10|4.26| |Safety integrity level|In<br>accordance<br>with IEC 61508||SIL 3| |Real time clock|||#| |Supply voltage|Us||24 V DC| |Networking|||easyNet/easyLink| |Safety/standard circuit diagram|||✓/✓| |**Instructions**|||Expandable: standard inputs/outputs and standard bus systems| ||||individual laser inscription with ES4-COMBINATION possible →#2011790| |Inputs (safety)|||14| |**Outputs (safety)**|||| |6 A relay|||| ||||4| |Test signal|||4| |**Technical data**|**Technical data**|||| |---|---|---|---|---| |**General**||||| ||Standards|||EN ISO 13849-1| |||||EN 50156-1, EN 50156-2| |||||EN 50178| |||||EN 50581_x| |||||EN 61000-6-2| |||||EN 61000-6-3| |||||IEC 61508| |||||IEC 62061| ||Approvals|||| ||Approvals|||EAC| ||Dimensions (W x H x D)||mm|107.5 (6 TE) x 90 x 72| ||Weight||kg|0.38| 07/12/2020 Eaton 111018 ED2020 V70.0 EN 1 / 7 **==> picture [536 x 747] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Mounting|Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1| |(accessories)| |Times| |Inputs| |Max. duration of external test pulde|ms|1| |Semi-conductor output| |Off test pulse|ms|< 1| |Off-delay|ms|< 1| |Terminal capacities| |Solid|mm|[2]|0.2/4 (AWG 22 - 12)| |Flexible with ferrule|mm|[2]|0.2/2.5 (AWG 22 - 12)| |Standard screwdriver|mm|0.8 x 3.5| |Max. tightening torque|Nm|0.6| |Climatic environmental conditions| |Operating ambient temperature|°C|-25 to + 55| |cold as per IEC 60068-2-1| |heat as per IEC 60068-2-2| |Damp heat – constant to IEC 60068-2-78 – cyclical to ICE 60068-2-30| |Condensation|Take appropriate measures to prevent condensation| |Ambient temperature| |Storage|ϑ|°C|-40 - +70| |relative humidity|%|5 - 95| |in accordance with IEC 60068-2-30, IEC 60068-2-78| |Non-condensing| |Air pressure (operation)|hPa|795 - 1080| |Ambient conditions, mechanical| |Degree of protection|IP20 (IEC/EN 60529, EN50178, VBG 4)| |Constant amplitude 0.15 mm|Hz| |constant amplitude|Hz|10 - 57 (0.15 mm)| |constant acceleration|Hz|57 - 150 (2g)| |Vibrations|3,5 mm / 1 g|Hz|In accordance with IEC 60068-2-6| |Mechanical shock resistance|g|18 shocks| |Sinusoidal 15 g/11 ms| |according to IEC 60068-2-27| |Drop to|Drop height|mm|50| |(IEC/EN 60068-2-31)| |Free fall, packaged|m|0,3| |(IEC/EN 61131-2)| |Electromagnetic compatibility (EMC)| |Electromagnetic compatibility|As per ICE 62061, increased EMC requirements for safety-relevant functions| |Overvoltage category/pollution degree|III/2| |Electrostatic discharge (ESD)| |applied standard|according to IEC EN 61000-4-2| |Air discharge|kV|15| |Contact discharge|kV|8| |Electromagnetic fields (RFI)|V/m|30to IEC EN 61000-4-3| |Radio interference suppression|EN 55011 Class B, EN 55022 Class B| |Burst|kV|according to IEC/EN 61000-4-4| |Supply cables: 4| |Signal cables: 4| |power pulses (Surge)|2 kV (supply cables, symmetrical)| |4 kV (semi-conductor outputs, symmetrical)| |In accordance with IEC 62061| |Immunity to line-conducted interference|V|20, in accordsnce with IEC/EN 61000-4-6| |Insulation resistance| |Clearance in air and creepage distances|EN 50178, UL 508, CSA C22.2, No. 142, EN 60664-1:2003| |Insulation resistance|EN 50178| |Back-up of real-time clock| |Back-up of real-time clock|meee|TTT|[rrr)]| **----- End of picture text -----**<br> ① Backup time (hours) with fully charged double layer capacitor 07/12/2020 Eaton 111018 ED2020 V70.0 EN 2 / 7 ||||② Service life (years)| |---|---|---|---| |Accuracy of the real-time clock||s/day|Normally ±2 (±0.5 h/year), may vary up to ±5 s/day depending on the ambient<br>temperature| |**Accuracy**|||| |Resolution|||| |Range “S”||ms|50| |Range “M:S”||s|1| |Range “H:M”||min|1| |**Repetition accuracy**|||| |Resolution|||| |Range “S”||ms|50| |Range “M:S”||s|1| |Range “H:M”||min|1| |**Retentive memory**|||| |Read/write cycles (minimum)|||100000000000000 (1014)| |**Power supply**|||| |Rated operational voltage|Ue|V|24 DC (-15/+20%)| |Permissible range|Ue||20.4 - 28.8 V DC| |Residual ripple||%|≦ 0| |Input current|||| |Input current 115/230 V AC||mA|< 250| |Voltage dips||ms|≤ 10<br>(IEC/EN 61131-2)| |Heat dissipation||W|< 6| |Potential isolation|||From the inputs: yes: no<br>from the outputs: yes<br>to PC interface: no<br>to easyLink:no<br>to easyNet: yes| |**Network easyNet**|||| |Stations||Number|max. 8| |Data transfer rate/distance|||1000 kBit/s, 6 m<br>500 kBit/s, 25 m<br>250 kBit/s, 40 m<br>125 kBit/s, 125 m<br>50 kBit/s, 300 m<br>20 kBit/s, 700 m<br>10 kBit/s, 1000 m| |Potential isolation|||| |Potential isolation between inputs and internal power supply|||yes| |Potential isolation|||from power supply: yes<br>From the inputs: yes<br>from the outputs: yes<br>to PC interface: yes<br>to memory card: yes<br>to easyLink: no<br>to easyNet: yes| |Bus termination|||yes (frst and last station)| |Connection technique|||<br>RJ45, 8-pole| |**Digital inputs 24 V DC**|||| |Number|||14| |Potential isolation|||from power supply: no<br>between digital inputs: no<br>from the outputs: yes<br>to the interface: no<br>to the memory card: no<br>to easyLink: no<br>to easyNet: yes| |Rated signal voltage|Ue|V DC|24| |On 0 signal|Ue|V DC|< 5| |On 1 signal|Ue|V DC|> 15,0| |Input current on 1 signal|||| |IS1 - IS14||mA|5.7 (at 24 V DC)| |Hardware delay time from 0 to 1||ms|| ||||Debounce ON: 24<br>Debounce OFF: 0.06 (IS1, IS2), 0.17 (IS3 to IS14)| |Hardware delay time from 1 to 0||ms|| 07/12/2020 Eaton 111018 ED2020 V70.0 EN 3 / 7 ||||Debounce ON: 24<br>Debounce OFF: 0.08 (IS1, IS2), 0.22 (IS3 to IS14)| |---|---|---|---| |Cable length (unscreened)||m|100| |Single cable length of test signal output to the device input (shielded)||m|1000| |Total of single cable lengths from one test signal output to the device inputs<br>(shielded)||m|3000| |Maximum rotary frequency at device inputs IS1 and IS2, when using function<br>block OM or ZM||Hz|1000| |Maximum switching frequency at input (does not apply to I1, I2, if function block<br>SM or OM is used)||Operation<br>h|s/<br>900| |**Test signal outputs**|||| |Number|||4 (T1 to T4)| |Voltage||V DC|24| |Potential isolation|||No| |**Relay outputs**|||| ||||4| |Outputs in groups of|||1| |Safety level|||3 redundant relay outputs, 6 months test interval<br>According to EN 50156| |Protection of an output relay|||Fuse: 6 A gL/gG,<br>Circuit-breaker with C characteristic: 4 A (only permissible with 24V DC),<br>Short-circuit current IK< 250 A| |Potential isolation|||from power supply: yes<br>From the inputs: yes<br>between digital inputs: yes<br>to the interface: yes<br>to easyNet: yes<br>to easyLink: yes<br>Safe isolation according to EN 50178: 300 V AC<br>Basic isolation: 600 V AC| |Lifespan, mechanical|Operations|x 106|10| |Contacts|||| |Conventional thermal current|Ith|A|6| |Rated impulse withstand voltage Uimpof contact coil||kV|6| |Rated operational voltage|Ue|V AC|250| |Rated insulation voltage|Ui|V AC|250| |safe isolation between coil and contact||V AC|300<br>in accordance with 50178| |Switching capacity|||DC-13, 24 V DC, 0.1 Hz: 40000 operations (in accordance with IEC 60947-5-1)<br>AC-15, 230 V AC, 3 A: 80000 operations (in accordance with IEC 60947-5-1)<br>DC: B300 (in accordance with UL 508)<br>AC: R300 (in accordance with UL 508)| |Switching frequency|||| |Mechanical operations||x 106|10| |Switching frequency||Hz|15| |**Transistor outputs**|||| |Residual ripple||%|5| ## **Desig per IEC/EN 61439** |**Design verifcation asper IEC/EN 61439**|||| |---|---|---|---| |<br>Technical data for design verifcation|||| |<br>Rated operational current for specifed heat dissipation|In|A|0| |Heat dissipation per pole, current-dependent|Pvid|W|0| |Equipment heat dissipation, current-dependent|Pvid|W|0| |Static heat dissipation, non-current-dependent|Pvs|W|6| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-25| |Operating ambient temperature max.||°C|55| |IEC/EN 61439 design verifcation|||| |<br>10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verifcation of thermal stability of enclosures|||Meets the product standard's requirements.| |<br>10.2.3.2 Verifcation of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| 07/12/2020 Eaton 111018 ED2020 V70.0 EN 4 / 7 10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements. |10.2.3.3 Verifcation of resistance of insulating materials to abnormal heat<br>and fre due to internal electric efects|||Meets the product standard's requirements.| |---|---|---|---| |<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 7.0** ## PLC's (EG000024) / Logic module (EC001417) Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014]) |**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**| |---|---|---|---| |PLC's (EG000024) / Logic module (EC001417)|||| |Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014])|||| |Supply voltage AC 50 Hz||V|0 - 0| |Supply voltage AC 60 Hz||V|0 - 0| |Supply voltage DC||V|20.4 - 28.8| |Voltage type of supply voltage|||DC| |Switching current||A|8| |Number of analogue inputs|||0| |Number of analogue outputs|||4| |Number of digital inputs|||14| |Number of digital outputs|||4| |With relay output|||Yes| |Number of HW-interfaces industrial Ethernet|||0| |Number of interfaces PROFINET|||0| |Number of HW-interfaces RS-232|||1| |Number of HW-interfaces RS-422|||0| |Number of HW-interfaces RS-485|||0| |Number of HW-interfaces serial TTY|||0| |Number of HW-interfaces USB|||0| |Number of HW-interfaces parallel|||0| |Number of HW-interfaces Wireless|||0| |Number of HW-interfaces other|||3| |With optical interface|||No| |Supporting protocol for TCP/IP|||No| |Supporting protocol for PROFIBUS|||No| |Supporting protocol for CAN|||No| |Supporting protocol for INTERBUS|||No| |Supporting protocol for ASI|||No| |Supporting protocol for KNX|||No| |Supporting protocol for MODBUS|||No| |Supporting protocol for Data-Highway|||No| 07/12/2020 Eaton 111018 ED2020 V70.0 EN 5 / 7 |Supporting protocol for DeviceNet|||No| |---|---|---|---| |Supporting protocol for SUCONET|||No| |Supporting protocol for LON|||No| |Supporting protocol for PROFINET IO|||No| |Supporting protocol for PROFINET CBA|||No| |Supporting protocol for SERCOS|||No| |Supporting protocol for Foundation Fieldbus|||No| |Supporting protocol for EtherNet/IP|||No| |Supporting protocol for AS-Interface Safety at Work|||No| |Supporting protocol for DeviceNet Safety|||No| |Supporting protocol for INTERBUS-Safety|||No| |Supporting protocol for PROFIsafe|||No| |Supporting protocol for SafetyBUS p|||No| |Supporting protocol for other bus systems|||Yes| |Radio standard Bluetooth|||No| |Radio standard WLAN 802.11|||No| |Radio standard GPRS|||No| |Radio standard GSM|||No| |Radio standard UMTS|||No| |IO link master|||No| |Redundancy|||Yes| |With display|||No| |Degree of protection (IP)|||IP20| |Basic device|||Yes| |Expandable|||Yes| |Expansion device|||No| |With timer|||Yes| |Rail mounting possible|||Yes| |Wall mounting/direct mounting|||Yes| |Front build in possible|||No| |Rack-assembly possible|||No| |Suitable for safety functions|||Yes| |Category according to EN 954-1|||4| |SIL according to IEC 61508|||3| |Performance level acc. EN ISO 13849-1|||Level e| |Appendant operation agent (Ex ia)|||No| |Appendant operation agent (Ex ib)|||No| |Explosion safety category for gas|||None| |Explosion safety category for dust|||None| |Width||mm|107.5| |Height||mm|90| |Depth||mm|72| ## **Approvals** |**Approvals**|||| |---|---|---|---| |Product Standards|||IEC/EN see Technical Data; UL 508; CSA-C22.20.4-04; CSA-22.2 No. 142-MI1987; CE<br>marking| |UL File No.|||CSA report applies to both US and Canada| |UL Category Control No.|||NRAQ| |CSA File No.|||012528| |CSA Class No.|||2252-81; 2252-01| |North America Certifcation|||CSA certifed, certifed by CSA for use in the US| |<br>Degree of Protection|||<br>IEC: IP20, UL/CSA Type: -| ## **Characteristics** PU05907001Z safety manual 07/12/2020 Eaton 111018 ED2020 V70.0 EN 6 / 7 ## **Dimensions** ## **Additional product information (links)** ## Instruction leaflet "easySafety ES4P safety ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL05013002Z2018_02.pdf relays" IL05013002Z-EN ## **Manual "easySafety ES4P control relays suitable for safety applications" MN05013001Z** Handbuch „Für Sicherheitsanwendungen ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013001Z_DE.pdf geeignete Steuerrelais easySafety ES4P“ MN05013001Z - Deutsch Manual "easySafety ES4P control relays ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013001Z_EN.pdf suitable for safety applications" MN05013001Z - English Manuel d'utilisation Module logique de ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013001Z_FR.pdf sécurité easySafety ES4P MN05013001Z - français Manuale relè di comando relativo alla ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05013001Z_IT.pdf sicurezza easySafety ES4P MN05013001Z - italiano f1=1454&f2=1175;Download easySoft-Safety http://applications.eaton.eu/sdlc?LX=11& f1=1454&f2=1179;Labeleditor http://applications.eaton.eu/sdlc?LX=11& Product overview (WEB) http://www.eaton.eu/es4p Eaton Industries GmbH http://www.eaton.eu © 07/2020 by Eaton Industries GmbH Eaton 111018 ED2020 V70.0 EN 07/12/2020 7 / 7
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →