EPP-400-12
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 400W @ 25CFM, 250 W, 80V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):250W; Power Rating (Forced Cooling):400W @ 25CFM; Input Voltage VAC:80V AC to 264V AC; Powe; Available until stocks are exhausted
- SVHC: No SVHC (27-Jun-2024)
- Product Range: EPP-400 Series
- No. of Outputs: 1 Output
- Output Power Max: 249.6W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20.8A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): 400W @ 25CFM
- Power Rating (Convection Cooling): 250W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 50.02 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- EPP 400 series** 400W Single Output with PFC Function **==> picture [13 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>**----- End of picture text -----**<br> ## ■ **** - ‧× - ‧ - ‧ - ‧Ⅰ - Ⅱ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - - ‧ - - ‧ - ‧Standby 5V@1A with fan , 0.6A without fan - ‧Built-in remote sense function - ‧ - ‧ - ‧ ## ■ **** ⅠⅡ ## ■ **** ** ** ~~[~~ _File Name:EPP-400-SPEC 2016-08-24_ 400W Single Output with PFC Function ## **- EPP 400 series** ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load<br>16ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>92%<br>91.5%<br>16.5 ~ 19.5V<br>93.5%<br>93%<br>29.7 ~ 35.1V<br>39.6 ~ 46.8V<br>4.2A/115VAC 2.1A/230VAC<br>COLD START 40A/115VAC 80A/230VAC<br>105 ~ 135% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>5VSB : 5V@0.6A without fan, 1A with fan 25CFM ; tolerance±2%, ripple : 120mVp-p(max.)<br>12V@0.5A for driving a fan ; tolerance±10%<br>Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"<br>500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal<br>goes low at least 1ms before Vo below 90% of rated value<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>194.1Khrs min. MIL-HDBK-217F (25℃)<br>127*76.2*35mm (L*W*H)<br>0.39Kg; 36pcs/15Kg/1.03CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±3.0%<br>±3.0%<br>±1.0%<br>±1.0%<br>120mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>25.6 ~ 28.4V<br>34.2 ~37.8V<br>150mVp-p<br>200mVp-p<br>250mVp-p<br>15V<br>27V<br>36V<br>33.3A<br>20.8A<br>26.7A<br>16.7A<br>14.9A<br>9.3A<br>11.2A<br>7A<br>399.6W<br>249.6W<br>250.5W<br>400.5W<br>251.1W<br>402.3W<br>252W<br>403.2W<br>**EPP-400-12**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>Protection type :Shut down o/p voltage, recovers automatically after temperature goes down<br>Protection type : Shut down o/p voltage, re-power on to recover<br>94%<br>52.8 ~ 62.4V<br>±0.5%<br>±1.0%<br>±1.0%<br>45.6 ~50.4V<br>250mVp-p<br>48V<br>8.4A<br>5.3A<br>254.4W<br>403.2W<br>93%<br>26.4 ~ 31.2V<br>±0.5%<br>±1.0%<br>±2.0%<br>22.8~25.2V<br>200mVp-p<br>24V<br>16.7A<br>10.5A<br>252W<br>400.8W<br>**EPP-400-15**<br>**EPP-400-24**<br>**EPP-400-27**<br>**EPP-400-36**<br>**EPP-400-48**<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br><0.75mA / 240VAC<br><br><br><br><br><br><br><br>ClassⅠ<br><br>Ⅱ<br>Class<br><br><br>|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load<br>16ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>92%<br>91.5%<br>16.5 ~ 19.5V<br>93.5%<br>93%<br>29.7 ~ 35.1V<br>39.6 ~ 46.8V<br>4.2A/115VAC 2.1A/230VAC<br>COLD START 40A/115VAC 80A/230VAC<br>105 ~ 135% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>5VSB : 5V@0.6A without fan, 1A with fan 25CFM ; tolerance±2%, ripple : 120mVp-p(max.)<br>12V@0.5A for driving a fan ; tolerance±10%<br>Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"<br>500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal<br>goes low at least 1ms before Vo below 90% of rated value<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>194.1Khrs min. MIL-HDBK-217F (25℃)<br>127*76.2*35mm (L*W*H)<br>0.39Kg; 36pcs/15Kg/1.03CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±3.0%<br>±3.0%<br>±1.0%<br>±1.0%<br>120mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>25.6 ~ 28.4V<br>34.2 ~37.8V<br>150mVp-p<br>200mVp-p<br>250mVp-p<br>15V<br>27V<br>36V<br>33.3A<br>20.8A<br>26.7A<br>16.7A<br>14.9A<br>9.3A<br>11.2A<br>7A<br>399.6W<br>249.6W<br>250.5W<br>400.5W<br>251.1W<br>402.3W<br>252W<br>403.2W<br>**EPP-400-12**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>Protection type :Shut down o/p voltage, recovers automatically after temperature goes down<br>Protection type : Shut down o/p voltage, re-power on to recover<br>94%<br>52.8 ~ 62.4V<br>±0.5%<br>±1.0%<br>±1.0%<br>45.6 ~50.4V<br>250mVp-p<br>48V<br>8.4A<br>5.3A<br>254.4W<br>403.2W<br>93%<br>26.4 ~ 31.2V<br>±0.5%<br>±1.0%<br>±2.0%<br>22.8~25.2V<br>200mVp-p<br>24V<br>16.7A<br>10.5A<br>252W<br>400.8W<br>**EPP-400-15**<br>**EPP-400-24**<br>**EPP-400-27**<br>**EPP-400-36**<br>**EPP-400-48**<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br><0.75mA / 240VAC<br><br><br><br><br><br><br><br>ClassⅠ<br><br>Ⅱ<br>Class<br><br><br>|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load<br>16ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>92%<br>91.5%<br>16.5 ~ 19.5V<br>93.5%<br>93%<br>29.7 ~ 35.1V<br>39.6 ~ 46.8V<br>4.2A/115VAC 2.1A/230VAC<br>COLD START 40A/115VAC 80A/230VAC<br>105 ~ 135% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>5VSB : 5V@0.6A without fan, 1A with fan 25CFM ; tolerance±2%, ripple : 120mVp-p(max.)<br>12V@0.5A for driving a fan ; tolerance±10%<br>Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"<br>500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal<br>goes low at least 1ms before Vo below 90% of rated value<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>194.1Khrs min. MIL-HDBK-217F (25℃)<br>127*76.2*35mm (L*W*H)<br>0.39Kg; 36pcs/15Kg/1.03CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±3.0%<br>±3.0%<br>±1.0%<br>±1.0%<br>120mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>25.6 ~ 28.4V<br>34.2 ~37.8V<br>150mVp-p<br>200mVp-p<br>250mVp-p<br>15V<br>27V<br>36V<br>33.3A<br>20.8A<br>26.7A<br>16.7A<br>14.9A<br>9.3A<br>11.2A<br>7A<br>399.6W<br>249.6W<br>250.5W<br>400.5W<br>251.1W<br>402.3W<br>252W<br>403.2W<br>**EPP-400-12**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>Protection type :Shut down o/p voltage, recovers automatically after temperature goes down<br>Protection type : Shut down o/p voltage, re-power on to recover<br>94%<br>52.8 ~ 62.4V<br>±0.5%<br>±1.0%<br>±1.0%<br>45.6 ~50.4V<br>250mVp-p<br>48V<br>8.4A<br>5.3A<br>254.4W<br>403.2W<br>93%<br>26.4 ~ 31.2V<br>±0.5%<br>±1.0%<br>±2.0%<br>22.8~25.2V<br>200mVp-p<br>24V<br>16.7A<br>10.5A<br>252W<br>400.8W<br>**EPP-400-15**<br>**EPP-400-24**<br>**EPP-400-27**<br>**EPP-400-36**<br>**EPP-400-48**<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br><0.75mA / 240VAC<br><br><br><br><br><br><br><br>ClassⅠ<br><br>Ⅱ<br>Class<br><br><br>|**EPP-400-12**|**EPP-400-15**|**EPP-400-24**|**EPP-400-27**|**EPP-400-36**|**EPP-400-48**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**||12V|15V|24V|27V|36V|48V| |||**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**RIPPLE & NOISE (max.)Note.2**|**25CFM**|33.3A|26.7A|16.7A|14.9A|11.2A|8.4A| ||||**Convection**|20.8A|16.7A|10.5A|9.3A|7A|5.3A| ||||**25CFM**|399.6W|400.5W|400.8W|402.3W|403.2W|403.2W| ||||**Convection**|249.6W|250.5W|252W|251.1W|252W|254.4W| |||||120mVp-p|150mVp-p|200mVp-p|200mVp-p|250mVp-p|250mVp-p| |||**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**||11.4~12.6V|14.3~15.8V|22.8~25.2V|25.6 ~ 28.4V|34.2 ~37.8V|45.6 ~50.4V| |||**VOLTAGE TOLERANCENote.3**||±3.0%|±3.0%|±2.0%|±1.0%|±1.0%|±1.0%| |||**LINE REGULATION**||±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**||±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| |||**SETUP, RISE TIME**||1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load|||||| |||**HOLD UP TIME(Typ.)**||16ms/230VAC 12ms/115VAC at full load|||||| |||**VOLTAGE RANGE Note.4**||80 ~ 264VAC 113 ~ 370VDC|||||| |||**FREQUENCY RANGE**||47 ~ 63Hz|||||| |||**POWER FACTOR**||PF>0.94/230VAC PF>0.98/115VAC at full load|||||| |||**EFFICIENCY(Typ.)**||91.5%|92%|93%|93.5%|93%|94%| |||**AC CURRENT(Typ.)**||4.2A/115VAC 2.1A/230VAC|||||| |||**INRUSH CURRENT(Typ.)**||COLD START 40A/115VAC 80A/230VAC|||||| |||**LEAKAGE CURRENT**||<0.75mA / 240VAC|||||| |||**OVERLOAD**||105 ~ 135% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||| |||**OVER VOLTAGE**||16.5 ~ 19.5V<br>29.7 ~ 35.1V<br>39.6 ~ 46.8V<br>13.2 ~ 15.6V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>52.8 ~ 62.4V<br>26.4 ~ 31.2V|||||| |||**OVER TEMPERATURE**||Protection type :Shut down o/p voltage, recovers automatically after temperature goes down|||||| |||**5V STANDBY**||5VSB : 5V@0.6A without fan, 1A with fan 25CFM ; tolerance±2%, ripple : 120mVp-p(max.)|||||| |||**FAN SUPPLY**||12V@0.5A for driving a fan ; tolerance±10%|||||| |||**PS-ON INPUT SIGNAL**||Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"|||||| |||**POWER GOOD / POWER FAIL**||500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal<br>goes low at least 1ms before Vo below 90% of rated value|||||| |||**WORKING TEMP.**||-30 ~ +70℃(Refer to "Derating Curve")|||||| |||**WORKING HUMIDITY**||20 ~ 90% RH non-condensing|||||| |||**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH|||||| |||**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 50℃)|||||| |||**VIBRATION**||10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||||| |||**SAFETY STANDARDS**||UL60950-1, TUV EN60950-1, IEC60950-1 approved|||||| |||**WITHSTAND VOLTAGE**||I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| |||**ISOLATION RESISTANCE**||I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||||| |||**EMC EMISSION**||Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3|||||| |||**EMC IMMUNITY**||Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A|||||| |||**MTBF**||194.1Khrs min. MIL-HDBK-217F (25℃)|||||| |||**DIMENSION**||127*76.2*35mm (L*W*H)|||||| |||**PACKING**||0.39Kg; 36pcs/15Kg/1.03CUFT|||||| |||<br><br><br><br><br><br><br>ClassⅠ<br><br>Ⅱ<br>Class<br><br><br>|||||||| _File Name:EPP-400-SPEC 2016-08-24_ **- EPP 400 series** ## 400W Single Output with PFC Function **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>+5VSB PFC fosc : 90KHz<br>DETECTION PWM fosc : 100KHz<br>CIRCUIT<br>POWER SWITCHING RECTIFIERS& +5VSB<br>PWM CONTROL FILTER<br>RECTIFIERS<br>& +12V FAN SUPPLY<br>FILTER<br>+S<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>PFC FILTER<br>-S<br>PG PG<br>FG DETECTION<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>PS/ON PS-ON<br>CONTROL<br>Derating Curve Output Derating VS Input Voltage<br>100<br>400<br>With 25CFM Fan<br>90<br>250<br>80<br>EPP-400:115VAC Converction 70<br>190<br>EPP-400:230VAC Converction 60<br>160<br>130 50<br>40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>Without Fan Watt 250W<br>With Fan Watt 400W<br>LOAD (W) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:EPP-400-SPEC 2016-08-24_ **EPP-4 00 series** ## 400W Single Output with PFC Function **==> picture [466 x 472] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>127<br>5.6 115.8<br>HS1 CN95<br>HS4<br>3 1<br>4 2<br>21<br>43<br>HS2 HS3 -V<br>CN1 +V<br>1<br>3<br>250VF8A 12<br>FS1<br>FG<br>Air flow<br>direction<br>FAN 25CFM<br>AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN2,CN3)<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Output Terminals<br>1 AC/N JST VHR JST SVH-21T-P1.1 CN2 -V M4 Pan HD screw in 2 positions<br>2 No Pin CN3 +V Torque to 8 lbs-in(90cNm)max.<br>or equivalent or equivalent<br>3 AC/L<br>Function Connector(CN11): TKP DH2I-2X2 or equivalent<br>Pin No. Assignment Mating Housing Terminal<br>Function Connector(CN95): TKP DH2L-2X2 or equivalent 1 -S<br>Pin No. Assignment Mating Housing Terminal 2 +S TKP DH2 TKP<br>1 5VSB 3 DC COM or equivalent or equivalent<br>2,4 DC COM TKP DH2 TKP 4 PG<br>or equivalent or equivalent<br>3 PS-ON<br><br>FAN Connector(CN12) : TKP 8812-2 or equivalent<br><br>Pin No. Assignment Mating Housing Terminal<br>1 DC COM TKP 2502 TKP 8811<br>2 +12V or equivalent or equivalent<br>4-<br>ψ<br>3.5<br>5.7<br>SVR1<br>CN11<br>76.2 64.8<br>ACL ACN<br>CN12<br>5cm<br>35<br>3 max.<br>**----- End of picture text -----**<br> - ※ Note: When the input voltage is AC 230V the model delivers EMI Class B for both conducted emission and radiated emission for the power supply, When the input voltage is AC110V the model delivers EMI Class B for conducted emission ,Class A for radiated emission for the power supply. - It delivers Class A for conduted emission and radiated emission, when configured into ClassⅡ (without FG) system. ## **Installation Manual** Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html _File Name:EPP-400-SPEC 2016-08-24_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →